Tender For Electrical Lighting System For The Vacuum Evaporation Plant
Tender Value
10.69 Lakhs
Estimated cost
Bid Submission
14 Aug 2024
0 days left
EMD
26726
Bank guarantee accepted
Document Fee
2522
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
trivandrum → Kerala
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Electrical Lighting System For The Vacuum Evaporation Plant Supply, Installation, Testing And Commissioning Of Electrical Lighting System For The Vacuum Evaporation Plant At Ttpl, Trivandrum
BOQ
| Sl. No. | Item Description |
| 1 | Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed,armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date.make:Universal cable/polycab, |
| 2 | 3.5C 50 sq mm Al |
| 3 | 4C 6sq mm Cu |
| 4 | 4C 2.5sq mm Cu |
| 5 | 3C 2.5sq mm Cu |
| 6 | Supplying and making end termination with brass double compression gland and aluminium/Copper lugs and cable gland earthing for following size of XLPE insulated PVC sheathed aluminium/copper conductor cable of 1.1 kV grade as required. |
| 7 | 3.5C 50sq mm Al |
| 8 | 4C 6sq mm Al |
| 9 | 4C 2.5sq mm Cu |
| 10 | Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 kV grade of following size on cable tray as required |
| 11 | Cable size upto 50sq mm |
| 12 | Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 kV grade of following size on wall or surface as required |
| 13 | Cable size upto 50sq mm (clamped with 25x3mm MS flat clamp) |
| 14 | Supply and fixing powder coated cubical panel after busbar extending in existing LDB panel provided at CRP plant. work includes supply of cubical panel suitable to existing LDB (size approximate 300mmx 300mm), powder coated, painting etc as required |
| 15 | supply,fixing, interconnecting and busbar extending with Aluminiumbusbar size (32x6mm) and its approximate length- 300mm/per phase.(3phase +1Neutal). Drilling ,holling fixing as required |
| 16 | Providing and fixing 125Amp 415volt 4poleMCCB 36KA with thermal and magnetic releases in newly provided above cubical panel board including drilling holes in cubical panel board ,making connection etc as required Make : L&T,Schneider,ABB |
| 17 | Supplying and fixing of 8 way double door, surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel,IP 54, IK 09 dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB\"s, with provision of 125 amps TP 16 KA MCCB as incomer, interconnection between incomer MCCB and bus bars, WITH END BOX TOP SIDE BOTOM SIDE (but without MCB\"s/ MCCB) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) MAKE : LEGRAND, HAVELLS, ABB,SCHNIDER |
| 18 | Supplying and fixing of 6 way (8 + 18), Double door , horizontal type three pole and neutral, sheet steel, MCB distribution board, IP54, IK 09, dust protected ,415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. WITH END BOX TOP SIDE BOTOM SIDE (But without MCB/RCCB/Isolator). MAKE : LEGRAND, HAVELLS, ABB,SCHNIDER |
| 19 | Supply Installation testing and commissioning of Single phase 6 way , single phase horizontal neutral, sheet steel, MCB distribution board, IP54, IK 09, dust protected ,220volt, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). MAKE : LEGRAND, HAVELLS, ABB,SCHNIDER |
| 20 | Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on wall surface as required . |
| 21 | Cable size upto 6 sq mm (clamped with 1mm thick saddle) |
| 22 | Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on existing cable trayasrequired |
| 23 | Cable size upto 6 sq mm |
| 24 | Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on wall surface as required |
| 25 | Cable size upto 2.5sq mm(clamped with 1mm thick saddle) |
| 26 | Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on existing cable tray as required |
| 27 | Cable size upto 2.5sq mm |
| 28 | Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on wall surface as required from VTPN to single phase 6 way DB (Instrumentation power supply) |
| 29 | Cable size upto 2.5sq mm(clamped with 1mm thick saddle) |
| 30 | Installation of 300mm size of ladder type FRPcable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling/wall with MS suspenders and painting etc as required |
| 31 | Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of zinc chromateprimer and two coats of enamel paint of approved make. |
| 32 | Supply Installation testing and commissioning of 4way flameproof lightingJunction Box IP-66 IIC, 4way with Threaded cover ,4nos of ¾” ET cable entry(1 No each from right,left,top &bottom),neoprene rubber gasket, 2 nos of brass stopper plug etc suitable for wall/column/steel structure |
| 33 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. |
| 34 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium steel conduit as required |
| 35 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 36 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 37 | Supplying and fixing following modular switch/ socket with modularplate & cover on surface or in recess, including proving and fixing suitable size GI box,inter connection etc as required complete. |
| 38 | 6 pin 15/16 amp socket outlet |
| 39 | 15/16 amp switch |
| 40 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 41 | . Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,IP 66 enclosed plug top alongwith 20 amps \"C\" curve, SP, MCB,,2P+E in the IP66 enclosure, on surface or in recess,complete with connections, testing and commissioning etc. as required. Make: Hensel/CAPE/SCAME/equivalent |
| 42 | Supply and fixing of following rating residual current circuit breaker withMCB having earth leakage and overload protection (RCCB+MCB) as per specification as required, Legrand/ABB/Schneider/L&T |
| 43 | 4 pole 32 amps. (415 Volts),30mA sensitivity. |
| 44 | 2 pole 16 amps. (215 Volts),30mA sensitivity. |
| 45 | Supply and fixing of following rating and breaking capacity and pole MCCB in existing cubical panel board(VTPN) including drilling holes in cubical panel , making connection as required make ABB,L&T,Schneider |
| 46 | 100A TP MCCB 36kA with thermal and magnetic releases |
| 47 | Supply and fixing of following rating, 10 KA, Miniature Circuit Breakersas required. Legrand/ABB/Schneider/L&T |
| 48 | 6A to 32A, SP, B/C-CURVE |
| 49 | 32 A 4P MCB, C-CURVE |
| 50 | 63 A TP MCB, C-CURVE |
| 51 | 16A Two pole isolator C Curve |
| 52 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 53 | Supply of LED batten 18 watts cool day light and including all necessary accessories as required complete.Make:- Wipro LL20-221-XXX-65-NE or bajaj/philips/crompton |
| 54 | Supply of outdoor IP 65 LED wellglass luminaire 35watts includingall necessary accessories are required complete Make: wipro LE02-441-XXX-57-OP /bajaj/philips/crompton |
| 55 | Supply of LED outdoor floodlight luminaire. The fixture shall be of IP66 protected, pressure die cast aluminium housing body with optimal heat sink, with system wattage of maximum 45 W with rated life of L70 @ 50,000 hours, CRI greater than or equal to 70 & with system lumens greater than 3800 lumen and system efficacy greater than or equal to 95%.Make Wipro LF19-471-060-57-XX or equivalent approved make |
| 56 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.(Rate shall inclusive of supply and installation of remote/electronic regulator) make: atomberg/havells/polycab/crompton |
| 57 | Installation, testing and commissioning of pre-wired, LED/ fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single corecable and earthing etc. as required. |
| 58 | Installation, testing and commissioning of High bay/Mid bay/LED/ FLOOD type fittings on wall/Column/truss/false ceiling using suitable MS clamps, nuts, bolts/ 20mm heavy duty GI chain/ pipe (upto 50cm)etc including connections with 3C 1.5 Sq.mm PVC insulated flexible copper conductor cableand copper lugs etc as required. |
| 59 | Supplyand laying of f GI strips 25mmx3mm (tinned at the point of contacts) on surface or recess for connection including welding of GI strip as required on wall surface/cable trayas required from VES to Acid Plant |
| 60 | Supplyand providing of 10SWG copper wireonsurface or recess from main earth bench to power circuits such as industrial socket,DB\"s etc |
AI Tender Summary
Tender Timeline
Jul 29, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedAug 14, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 16, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender