Public Administrative Department Government Departments Closing in 0 days TDR #44460970

Tender For Annual Operation And Maintenance Of Existing Infrastructure Comprising Of Electromechanical Equipments Internal External Electrical System In Jksidco Managed Industrial Complexes Of Jammu Division

Issued by Government Departments · jammu, Jammu And Kashmir
Tender Value
Ref. Documents
Estimated cost
Bid Submission
31 Aug 2024
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
1500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
jammu → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Annual Operation And Maintenance Of Existing Infrastructure Comprising Of Electromechanical Equipments Internal External Electrical System In Jksidco Managed Industrial Complexes Of Jammu Division-- 1 Complete rewinding of following submersible Motors including rebate of old material. 2 5 HP Capacity 3 7.5 HP Capacity 4 10 HP Capacity 5 12.5HP Capacity 6 15 HP Capacity 7 17.5 HP Capacity 8 20 HP Capacity 9 22.5 HP Capacity 10 25 HP Capacity 11 Complete rewinding of horizontal Squirrel Cage Motors High Speedtype including rebate of old material 12 5 HP Capacity 13 7.5 HP Capacity 14 10 HP Capacity 15 Repair to 5/7.5HP/10HP capacity motor by way of replacement of bearing at DE and NDE and assembling of motor. 16 Repair to 5/7.5HP/10HP capacity motor by way of welding, turning, polishingof shaft , sleeve to end covers and assembling of motor etc. 17 Disconnecting the electrical connection, disengaging the pump motor set from base frame , making alignment, all electrical connection and testing therof. 18 Loading of motor pump set into mechanical transport and carriage to workshop and unloading thereof. Loading the motor pump set into mechanical transport and carriage to site and unloading thereof by using skilled/unskilled labour and other tools and tackles 19 Up to 10 Km 20 Above 10Km upto 15Km 21 Loading of damaged Submersible Motor (V4) from site of work by way of head load carriage to Mechanical Transport and carriage back to site of work after repairing and unloading at site up to 10KM 22 Loading of damaged Submersible Motor (V6) from site of work by way of head load carriage to Mechanical Transport and carriage back to site of work after repairing and unloading at site up to 10KM 23 Submersible Pump V4 to V8 24 Disconnecting of power supply and testingof pump at site 25 Dismantling of submersible pump set at workshop and checking for its replacement of damaged parts. 26 Providing and fitting of new pump shaft 27 Reconditioning of pump shaft by way of welding, turning and polishing to actual size, making of key way 28 Providing and fitting of new cast iron impeller. 29 Reconditioning of impeller by way of welding, turning and polishing to the actual size. 30 Providing and fitting of new Neck Ring. 31 Providing and fitting of Shaft Sleeve. 32 Providing and fitting of Coupling with key 33 Providing and fitting of Bowl Bush 34 Providing and fitting of NRV Bowl. 35 Providing and fitting of Tee Bolts/per piece 36 Providing and fitting of Stud fasting ring with studs upper and lower and circlip lock. 37 Providing and fitting of Diffuser. 38 Providing and fitting of thrust bearing / thrust pad set 39 Assembling of Pump and then coupling with motor with proper alignment. Testing in test pit at workshop. 40 Providing and fitting of copper submersible cable 3 core along with thimbles 41 2.5 Sqmm 42 4Sqmm 43 6Sqmm 44 10Sqmm 45 16Sqmm 46 Extraction out of Submersible Motor pump set 47 Extraction out2.5 inch dia to 4 inch dia column pipes from tube by way of Disconnecting of Power connections from starter panel, disengaging from delivery bend and extracting out Submersible Pump Set complete along with column pipes by hoisting chain pulley block at Tube well, stacking of column pipes and Submersible cable properly. 48 Column pipes 0 to 10 Nos 49 Column pipes 10 to 20 Nos 50 Loweringof Submersible Motor pump set 51 Lowering of2.5 inch dia to 4 inch dia column pipes in Tube well byMaking of cable connection of motor with Submersible cable after dressing cable ends properly. Making of each joint water proof. Lowering of Submersible Pump Set complete along with column pipes and submersible cable with providing & fitting of jointing material and nuts and bolts. Making of connections to the starter panel 52 Column pipes 0 to 10 Nos 53 Column pipes 10 to 20 Nos 54 Star Delta control panels for Submersible pump set 55 Disconnection ofincomingPowerconnectionfrommainswitch /MCCB/Voltage Stabilizer and checking of fault. Making of temporary arrangement for running of pumpingmachinery 56 Providing and fittingof Damaged Contactor of following ratings 57 MNX 25 Amp 58 MNX 45 Amp 59 MNX 50 Amp 60 MNX 70 Amp 61 MNX 95 Amp 62 MNX 110 Amp 63 Providing and fittingof Damaged Kit of following rating contactors 64 MNX 25 Amp. 65 MNX 45 Amp. 66 MNX 50 Amp. 67 MNX 70 Amp. 68 MNX 95 Amp. 69 MNX 110 Amp. 70 Providing and fittingof Damaged coil of following rating contactors 71 MNX 25 Amp. 72 MNX 45 Amp. 73 MNX 50 Amp. 74 MNX 70 Amp. 75 MNX 95 Amp. 76 MNX 110 Amp. 77 Providing & Fitting of Auxiliary block 78 Providing & Fitting of Aluminum Bus Bar 79 Providing & Fitting of damaged over load relay & P/F new overload Relay 80 Providing & Fitting of damagedundervolt relay&P/Fnew relay 81 Providing & Fitting of single phase preventer ( L&T) 82 Providing & Fittingof DamagedMCCB 83 63 Amp 4pole 16KA 84 100 Amp 4pole 16KA 85 160Amp 4pole 16KA 86 200 Amp 4pole 36KA 87 250 Amp 4pole 36KA 88 400 Amp 4pole 50KA 89 630 Amp 4pole 50KA 90 Making of incomingPowerconnectiontomainswitch/MCCB/Servo Stabilizer and checking on full load at site 91 Control Star delta panel up 15 to 100 Amp. 92 Chargesforminorrepair/servicingofLTControlPanel including minorparts like meters, indicators , timers etc 93 Providing /fitting of circuit wiring 94 Providing /fitting of voltmeter Analog 95 Providing /fitting of amp meter Analog 96 Providing /fitting of Amp selector switch 97 Providing/ Fitting ofdigital Volt meter 98 Providing / Fitting of digital Amper meterCT operated 99 Providing /fitting of volt selector switch 100 Providing /fitting of Push Button on/off 101 Providing /fitting of indicator lamps R/4/B 102 Providing /fitting of star delta timer 103 Providing /fitting of terminal plate 104 Providing /fitting of quartz timer 105 Providing /fitting of delay timerProviding /fitting of delay timer 106 Providing /fitting of power wiring 107 Providing /fitting of thermal overload relay 108 Providing /fitting of bus bar 109 Providing /fitting of fuse link 110 Providing /fitting of fuse holder suitable for bolted fuse link 111 Servo Stabilizer 25 to 50 KVA Capacity 112 Rewinding of copper Coil & fitting etc at site. 113 Providing & Fitting of Dimmer coil 60Amp. 114 Providing & Fitting of Change Over Switch 100 ampere 115 Providing & Fitting of Change Over Switch 100 ampere 116 Providing & Fitting of digital Control card 117 Providing & Fitting of carbon brushes 118 Providing & Fitting of moving arm 119 Providing & Fitting of RC circuit 120 Providing & Fitting of toggle switch for auto /manual 121 Providing & Fitting of CT 100/5A 122 Providing & Fitting of limit switch 123 Providing & Fitting of gear wheel 124 Providing & Fitting of Indicator 125 Providing & Fitting of Selector Switch 126 Providing & Fitting of Ampere meter 127 Providing & Fitting of Voltmeter 128 Fresh Transformer Oil per litre 129 Providing & Fitting of Nut Bolts 130 Complete power wiringwith thimbling 131 Complete top panel wiringwith thimbling 132 Disconnecting of power connection of the servo Stabilizer, dismantling of stabilizer by unscrewing nut bolts. Extracting out of stabilizer coil structure by mounting of chain pulley block with the help of manual skilled labour. 133 Distribution Transformers 134 63KVA Capacity Transformer 135 Disconnecting of distribution transformer HT links and HT/ LT side cables. Dismounting from poles/platform using crane / skilled and un-skilled labour using tools and tackles, loading in Mechanical transport and carriage to workshop and unloading at workshop. Providing and installing transformer from its own temporarily to run the station till the damaged transformer is repaired and installed where standby not available 136 Draining of Transformer oil in barrels, dismantling of top cover and extracting out assembly using chain pulley block and tripod and checking for fault. 137 Reconditioning of LV Aluminium coilper kg 138 Providing and fitting of HV leg coil Aluminium SE (per Kg) 139 Providing and fitting of HV leg coil Aluminium DPC(per Kg) 140 Providing and fitting of LV leg coil Aluminium DPC (per Kg) 141 Providing & fitting of HV bushing 142 Providing& fitting of LV bushing 143 Providing& fitting of HV bush rod (metal part)per rod 144 Providing& fitting of LV bush rod (metal part) per rod 145 Providing& fitting of gasket set 146 Providing& fitting of tapping switch with handle 147 Providing & fitting of LT terminal plate 148 Providing & fitting of Oil drain valve 149 Providing & fitting of core laminations per Kg 150 Providing& fitting of sundry items 151 Heat treatment of repaired transformer 152 Arresting of oil leakages if any by way of welding etc. 153 Painting of transformer body 154 Silica Gel breather 155 Providing & Fitting of fresh T-oil 156 Assembling of transformer and lowering into the tank using chain pulley block and tripod. Assembling of top cover thereof and filling of transformer oil after dehydrating. 157 Loading of transformer into Mechanical transport using crane / skilled and un-skilled labour using tools and tackles and carriage to the site of work (For Urban areas). Mounting the transformer on poles/ platform with the help of crane / skilled and un-skilled labour using tools and tackles after dismounting the temporarily installed transformer 158 100KVA Capacity Transformer 159 Disconnecting of distribution transformer HT links and HT/ LT side cables. Dismounting from poles/platform using crane / skilled and un-skilled labour using tools and tackles, loading in Mechanical transport and carriage to workshop and unloading at workshop. Providing and installing transformer from its own temporarily to run the station till the damaged transformer is repaired and installed where standby not available 160 Draining of Transformer oil in barrels, dismantling of top cover and extracting out assembly using chain pulley block and tripod and checking for fault. 161 Reconditioning of LV Aluminum coilper kg 162 Providing and fitting of HV leg coil Aluminium SE (per Kg) 163 Providing and fitting of HV leg coil Aluminium DPC(per Kg) 164 Providing and fitting of LV leg coil Aluminium DPC (per Kg) 165 Providing & fitting of HV bushing 166 Providing& fitting of LV bushing 167 Providing& fitting of HV bush rod (metal part)per rod 168 Providing& fitting of LV bush rod (metal part) per rod 169 Providing& fitting of gasket set 170 Providing& fitting of tapping switch with handle 171 Providing & fitting of LT terminal plate 172 Providing & fitting of Oil drain valve 173 Providing & fitting of core laminations per Kg 174 Providing& fitting of sundry items 175 Heat treatment of repaired transformer 176 Arresting of oil leakages if any by way of welding etc. 177 Painting of transformer body 178 Silica Gel breather 179 Providing & Fitting of fresh T-oil 180 Assembling of transformer and lowering into the tank using chain pulley block and tripod. Assembling of top cover thereof and filling of transformer oil after dehydrating. 181 Loading of transformer into Mechanical transport using crane / skilled and un-skilled labour using tools and tackles and carriage to the site of work (For Urban areas). Mounting the transformer on poles/ platform with the help of crane / skilled and un-skilled labour using tools and tackles after dismounting the temporarily installed transformer 182 250KVA Capacity Transformer 183 Disconnecting of distribution transformer HT links and HT/ LT side cables. Dismounting from poles/platform using crane / skilled and un-skilled labour using tools and tackles, loading in Mechanical transport and carriage to workshop and unloading at workshop. Providing and installing transformer from its own temporarily to run the station till the damaged transformer is repaired and installed where standby not available 184 Draining of Transformer oil in barrels, dismantling of top cover and extracting out assembly using chain pulley block and tripod and checking for fault. 185 Reconditioning of LV Aluminum coilper kg 186 Providing and fitting of HV leg coil Aluminium SE (per Kg) 187 Providing and fitting of HV leg coil Aluminium DPC(per Kg) 188 Providing and fitting of LV leg coil Aluminium DPC (per Kg) 189 Providing & fitting of HV bushing 190 Providing& fitting of LV bushing 191 Providing& fitting of HV bush rod (metal part)per rod 192 Providing& fitting of LV bush rod (metal part) per rod 193 Providing& fitting of gasket set 194 Providing& fitting of tapping switch with handle 195 Providing & fitting of LT terminal plate 196 Providing & fitting of Oil drain valve 197 Providing & fitting of core laminations per Kg 198 Providing& fitting of sundry items 199 Heat treatment of repaired transformer 200 Arresting of oil leakages if any by way of welding etc. 201 Painting of transformer body 202 Silica Gel breather 203 Assembling of transformer and lowering into the tank using chain pulley block and tripod. Assembling of top cover thereof and filling of transformer oil after dehydrating. 204 Loading of transformer into Mechanical transport using crane / skilled and un-skilled labour using tools and tackles and carriage to the site of work (For Urban areas). Mounting the transformer on poles/ platform with the help of crane / skilled and un-skilled labour using tools and tackles after dismounting the temporarily installed transformer 205 Making of LT side cable connections as well as HT side cable connections and charging the transformer on no load conditions and thereafter checking on full load conditions. 206 Providing and filling of transformer oil for topping (per litre) 207 Providing & fitting of Lighting arrestor station type 208 Providing & fitting of Lighting disc insulator with accessory polymer type 209 Providing & fitting of Lighting pininsulator with pin polymer type 210 Providing & fitting of Lighting AB switch 400Amp with handle operated. 211 Providing & fitting of Lighting AB switch 200Amp with handle operated. 212 Providing & fitting of horn gap DO switch 213 Providing & fitting of Prodigy meter 214 Providing & fitting of chemical earthing 215 Providing & Fixing of Aluminum unarmored cable 1x120 Sq.mm 216 Providing & Fixing of Aluminum narmoured cable 1x185 Sq.mm 217 Road lighting network 218 Providing & fitting with LED fitting 60/65 Watt along with allied Nipple for fixing of LED Fitting with wiremesh protection etc. 219 Providing and fitting of MCB/ SPN installed for controlling of Road lighting Network of following 220 SPN 32Amp 221 TPN MCB 32Amp. 222 Supply and fixing of dust and weather proof gasketted 250mm x 250mm x 200 mm deep cable looping box (nominal) size made out of 18 SWG fitted with pole with the help of 2 Nos. MS clamp (25x3mm) thick flat strip of suitable size with nuts and bolts. Complete with hinged cover locking L-Key/Nut Bolts type, earth studs suitable for poles mounted including supply and fixing of 6A MCB SP, MCB carrier and 4-way 63A terminal block fixed on suitable size and suitable for receiving PVC armoured cable complete with connections and painting etc. 223 Providing and fittingof connection strip 63Amp 4pole heavy duty 224 Providing & Fixing of prodigy meter 225 Providing and fitting of SP MCB 6Amp. in existing connection box 226 Repairingof existing 150/160 Watt LED light 227 Providing and fitting of connection wire 2x1.5 sq mm in steel tubular pole. 228 Fabrication, Supplying and fixing of 40mm dia MS pipe (Medium Class) bracket for mounting LED Street light fitting on pole at appropriate place including bending to required shape at 105 degree, 2 nos 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting to clamps with primer and finish paint etc as required complete Job. 229 Providing and fitting of contractor MNX 9Amp. For timer 230 Providing and fitting Solar/Quartz timer 231 Cables of following sizes 232 Providing & laying of Aluminum armored in ground 2.5feet below the ground level along with HDPC pipe 40mm Dia of Following sizes:- 233 2x10 Sq.mm 234 4x10Sqmm 235 4x16Sqmm 236 4x25 Sqmm 237 4x35 Sqmm 238 3.5x50Sqmm 239 Internal Electrification 240 Providing & fixing fall ceiling light 6/7 watt 241 Providing & fixing fall ceiling light 9/10 watt 242 Providing & fixing fall ceiling light 12 watt 243 Providing & fixing LED tube light complete fitting 20 watt 244 Providing & fixing LED bulb 9 watt 245 Providing & fixingmodular switch 5/6Amp 246 Providing & fixingmodular switch 15/16Amp 247 Providing & fixingmodular socket 5/6Amp 248 Providing & fixing modular socket 15/16Amp 249 Providing & fixingmodular bell push 250 Providing & fixingFan dimmer 251 Providing & fixing modular plate 2 module 252 Providing & fixing modular plate 3 module 253 Providing & fixingmodular plate4module 254 Providing & fixingmodular plate 6 module 255 Providing & fixingmodular plate 12 module 256 Providing & fixingSPN 32 amp in existing DB 257 Providing & fixingSP 6 to 32 amp in existing DB 258 Providing & fixingTPN 32 amp in existing DB 259 Providing & fixingmodular plate 6 module 260 Providing & fixingof following size single core copper wire in existing conduit. 261 1x1.5 sqmm 262 1x2.5 sqmm 263 1x4 sqmm 264 1x6 sqmm 265 Providing & fixingCeiling fan 1200mmbase model 266 Providing & fixingexhaust fan 300mm 267 Providing & fixingInverter 1000VA 268 Providing & fixingInverter 2000VA 269 Invertor Battery 160 AH 270 Servicing of window/spilt AC 271 Water distribution system 272 Providing & laying of GI pipe, complete with fitting in ground including trench & refilling the same. 273 40mm Dia 274 50mm Dia 275 65mm Dia 276 80mm Dia 277 100mm Dia 278 Providing & laying of GI Elbow of following sizes:- 279 40mm Dia 280 50mm Dia 281 65mm Dia 282 80mm Dia 283 Providing & laying of GI Socket of following sizes:- 284 40mm Dia 285 50mm Dia 286 65mm Dia 287 100mm Dia 288 Providing & fixing of MS flange of following sizes:- 289 2 inch 290 2.5 inch 291 3 inch 292 4 inch 293 5 inch 294 Providing & fixing Sluice Valvecast Iron (Heavy Duty) 295 50mmǾ 296 65mmǾ 297 80mmǾ 298 100mmǾ 299 125mmǾ 300 150mmǾ 301 Providing & fixing NRV cast Iron (Heavy Duty) 302 50mmǾ 303 65mmǾ 304 80mmǾ 305 100mmǾ 306 125mmǾ 307 150mmǾ 308 Repairing of cast Iron valve with finishing and polishing 309 50mmǾ 310 65mmǾ 311 80mmǾ 312 100mmǾ 313 125mmǾ 314 150mmǾ 315 Jointing of MS/GI pipe 50mmdia to make leak proof 316 50mmǾ 317 65mmǾ 318 80mmǾ 319 100mmǾ 320 125mmǾ 321 150mmǾ 322 Providing and fittingof short bend of following sizes 323 80mmǾ 324 100mm 325 150mm 326 Providing and fittingof Long bend of following sizes 327 80mm 328 100mm 329 150mm 330 Providing and fittingPuncher Roll to make leak proof connection 331 Adhesive Tape

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 27-Aug-2024 corrigendum Date 31-Aug-2024

BOQ

Name of Work: ANNUAL OPERATION AND MAINTENANCE OF EXISTING INFRASTRUCTURE COMPRISING OF ELECTRO-MECHANICAL EQUIPMENT’S, INTERNAL/EXTERNAL ELECTRICAL SYSTEM IN J&KSIDCO, MANAGED INDUSTRIAL COMPLEXES OF JAMMU DIVISION
Sl. No. Item Description
1Complete rewinding of following submersible Motors including rebate of old material.
25 HP Capacity
37.5 HP Capacity
410 HP Capacity
512.5HP Capacity
615 HP Capacity
717.5 HP Capacity
820 HP Capacity
922.5 HP Capacity
1025 HP Capacity
11Complete rewinding of horizontal Squirrel Cage Motors High Speedtype including rebate of old material
125 HP Capacity
137.5 HP Capacity
1410 HP Capacity
15Repair to 5/7.5HP/10HP capacity motor by way of replacement of bearing at DE and NDE and assembling of motor.
16Repair to 5/7.5HP/10HP capacity motor by way of welding, turning, polishingof shaft , sleeve to end covers and assembling of motor etc.
17Disconnecting the electrical connection, disengaging the pump motor set from base frame , making alignment, all electrical connection and testing therof.
18Loading of motor pump set into mechanical transport and carriage to workshop and unloading thereof. Loading the motor pump set into mechanical transport and carriage to site and unloading thereof by using skilled/unskilled labour and other tools and tackles
19Up to 10 Km
20Above 10Km upto 15Km
21Loading of damaged Submersible Motor (V4) from site of work by way of head load carriage to Mechanical Transport and carriage back to site of work after repairing and unloading at site up to 10KM
22Loading of damaged Submersible Motor (V6) from site of work by way of head load carriage to Mechanical Transport and carriage back to site of work after repairing and unloading at site up to 10KM
23Submersible Pump V4 to V8
24Disconnecting of power supply and testingof pump at site
25Dismantling of submersible pump set at workshop and checking for its replacement of damaged parts.
26Providing and fitting of new pump shaft
27Reconditioning of pump shaft by way of welding, turning and polishing to actual size, making of key way
28Providing and fitting of new cast iron impeller.
29Reconditioning of impeller by way of welding, turning and polishing to the actual size.
30Providing and fitting of new Neck Ring.
31Providing and fitting of Shaft Sleeve.
32Providing and fitting of Coupling with key
33Providing and fitting of Bowl Bush
34Providing and fitting of NRV Bowl.
35Providing and fitting of Tee Bolts/per piece
36Providing and fitting of Stud fasting ring with studs upper and lower and circlip lock.
37Providing and fitting of Diffuser.
38Providing and fitting of thrust bearing / thrust pad set
39Assembling of Pump and then coupling with motor with proper alignment. Testing in test pit at workshop.
40Providing and fitting of copper submersible cable 3 core along with thimbles
412.5 Sqmm
424Sqmm
436Sqmm
4410Sqmm
4516Sqmm
46Extraction out of Submersible Motor pump set
47Extraction out2.5 inch dia to 4 inch dia column pipes from tube by way of Disconnecting of Power connections from starter panel, disengaging from delivery bend and extracting out Submersible Pump Set complete along with column pipes by hoisting chain pulley block at Tube well, stacking of column pipes and Submersible cable properly.
48Column pipes 0 to 10 Nos
49Column pipes 10 to 20 Nos
50Loweringof Submersible Motor pump set
51Lowering of2.5 inch dia to 4 inch dia column pipes in Tube well byMaking of cable connection of motor with Submersible cable after dressing cable ends properly. Making of each joint water proof. Lowering of Submersible Pump Set complete along with column pipes and submersible cable with providing & fitting of jointing material and nuts and bolts. Making of connections to the starter panel
52Column pipes 0 to 10 Nos
53Column pipes 10 to 20 Nos
54Star Delta control panels for Submersible pump set
55Disconnection ofincomingPowerconnectionfrommainswitch /MCCB/Voltage Stabilizer and checking of fault. Making of temporary arrangement for running of pumpingmachinery
56Providing and fittingof Damaged Contactor of following ratings
57MNX 25 Amp
58MNX 45 Amp
59MNX 50 Amp
60MNX 70 Amp
61MNX 95 Amp
62MNX 110 Amp
63Providing and fittingof Damaged Kit of following rating contactors
64MNX 25 Amp.
65MNX 45 Amp.
66MNX 50 Amp.
67MNX 70 Amp.
68MNX 95 Amp.
69MNX 110 Amp.
70Providing and fittingof Damaged coil of following rating contactors
71MNX 25 Amp.
72MNX 45 Amp.
73MNX 50 Amp.
74MNX 70 Amp.
75MNX 95 Amp.
76MNX 110 Amp.
77Providing & Fitting of Auxiliary block
78Providing & Fitting of Aluminum Bus Bar
79Providing & Fitting of damaged over load relay & P/F new overload Relay
80Providing & Fitting of damagedundervolt relay&P/Fnew relay
81Providing & Fitting of single phase preventer ( L&T)
82Providing & Fittingof DamagedMCCB
8363 Amp 4pole 16KA
84100 Amp 4pole 16KA
85160Amp 4pole 16KA
86200 Amp 4pole 36KA
87250 Amp 4pole 36KA
88400 Amp 4pole 50KA
89630 Amp 4pole 50KA
90Making of incomingPowerconnectiontomainswitch/MCCB/Servo Stabilizer and checking on full load at site
91Control Star delta panel up 15 to 100 Amp.
92Chargesforminorrepair/servicingofLTControlPanel including minorparts like meters, indicators , timers etc
93Providing /fitting of circuit wiring
94Providing /fitting of voltmeter Analog
95Providing /fitting of amp meter Analog
96Providing /fitting of Amp selector switch
97Providing/ Fitting ofdigital Volt meter
98Providing / Fitting of digital Amper meterCT operated
99Providing /fitting of volt selector switch
100Providing /fitting of Push Button on/off
101Providing /fitting of indicator lamps R/4/B
102Providing /fitting of star delta timer
103Providing /fitting of terminal plate
104Providing /fitting of quartz timer
105Providing /fitting of delay timerProviding /fitting of delay timer
106Providing /fitting of power wiring
107Providing /fitting of thermal overload relay
108Providing /fitting of bus bar
109Providing /fitting of fuse link
110Providing /fitting of fuse holder suitable for bolted fuse link
111Servo Stabilizer 25 to 50 KVA Capacity
112Rewinding of copper Coil & fitting etc at site.
113Providing & Fitting of Dimmer coil 60Amp.
114Providing & Fitting of Change Over Switch 100 ampere
115Providing & Fitting of Change Over Switch 100 ampere
116Providing & Fitting of digital Control card
117Providing & Fitting of carbon brushes
118Providing & Fitting of moving arm
119Providing & Fitting of RC circuit
120Providing & Fitting of toggle switch for auto /manual
121Providing & Fitting of CT 100/5A
122Providing & Fitting of limit switch
123Providing & Fitting of gear wheel
124Providing & Fitting of Indicator
125Providing & Fitting of Selector Switch
126Providing & Fitting of Ampere meter
127Providing & Fitting of Voltmeter
128Fresh Transformer Oil per litre
129Providing & Fitting of Nut Bolts
130Complete power wiringwith thimbling
131Complete top panel wiringwith thimbling
132Disconnecting of power connection of the servo Stabilizer, dismantling of stabilizer by unscrewing nut bolts. Extracting out of stabilizer coil structure by mounting of chain pulley block with the help of manual skilled labour.
133Distribution Transformers
13463KVA Capacity Transformer
135Disconnecting of distribution transformer HT links and HT/ LT side cables. Dismounting from poles/platform using crane / skilled and un-skilled labour using tools and tackles, loading in Mechanical transport and carriage to workshop and unloading at workshop. Providing and installing transformer from its own temporarily to run the station till the damaged transformer is repaired and installed where standby not available
136Draining of Transformer oil in barrels, dismantling of top cover and extracting out assembly using chain pulley block and tripod and checking for fault.
137Reconditioning of LV Aluminium coilper kg
138Providing and fitting of HV leg coil Aluminium SE (per Kg)
139Providing and fitting of HV leg coil Aluminium DPC(per Kg)
140Providing and fitting of LV leg coil Aluminium DPC (per Kg)
141Providing & fitting of HV bushing
142Providing& fitting of LV bushing
143Providing& fitting of HV bush rod (metal part)per rod
144Providing& fitting of LV bush rod (metal part) per rod
145Providing& fitting of gasket set
146Providing& fitting of tapping switch with handle
147Providing & fitting of LT terminal plate
148Providing & fitting of Oil drain valve
149Providing & fitting of core laminations per Kg
150Providing& fitting of sundry items
151Heat treatment of repaired transformer
152Arresting of oil leakages if any by way of welding etc.
153Painting of transformer body
154Silica Gel breather
155Providing & Fitting of fresh T-oil
156Assembling of transformer and lowering into the tank using chain pulley block and tripod. Assembling of top cover thereof and filling of transformer oil after dehydrating.
157Loading of transformer into Mechanical transport using crane / skilled and un-skilled labour using tools and tackles and carriage to the site of work (For Urban areas). Mounting the transformer on poles/ platform with the help of crane / skilled and un-skilled labour using tools and tackles after dismounting the temporarily installed transformer
158100KVA Capacity Transformer
159Disconnecting of distribution transformer HT links and HT/ LT side cables. Dismounting from poles/platform using crane / skilled and un-skilled labour using tools and tackles, loading in Mechanical transport and carriage to workshop and unloading at workshop. Providing and installing transformer from its own temporarily to run the station till the damaged transformer is repaired and installed where standby not available
160Draining of Transformer oil in barrels, dismantling of top cover and extracting out assembly using chain pulley block and tripod and checking for fault.
161Reconditioning of LV Aluminum coilper kg
162Providing and fitting of HV leg coil Aluminium SE (per Kg)
163Providing and fitting of HV leg coil Aluminium DPC(per Kg)
164Providing and fitting of LV leg coil Aluminium DPC (per Kg)
165Providing & fitting of HV bushing
166Providing& fitting of LV bushing
167Providing& fitting of HV bush rod (metal part)per rod
168Providing& fitting of LV bush rod (metal part) per rod
169Providing& fitting of gasket set
170Providing& fitting of tapping switch with handle
171Providing & fitting of LT terminal plate
172Providing & fitting of Oil drain valve
173Providing & fitting of core laminations per Kg
174Providing& fitting of sundry items
175Heat treatment of repaired transformer
176Arresting of oil leakages if any by way of welding etc.
177Painting of transformer body
178Silica Gel breather
179Providing & Fitting of fresh T-oil
180Assembling of transformer and lowering into the tank using chain pulley block and tripod. Assembling of top cover thereof and filling of transformer oil after dehydrating.
181Loading of transformer into Mechanical transport using crane / skilled and un-skilled labour using tools and tackles and carriage to the site of work (For Urban areas). Mounting the transformer on poles/ platform with the help of crane / skilled and un-skilled labour using tools and tackles after dismounting the temporarily installed transformer
182250KVA Capacity Transformer
183Disconnecting of distribution transformer HT links and HT/ LT side cables. Dismounting from poles/platform using crane / skilled and un-skilled labour using tools and tackles, loading in Mechanical transport and carriage to workshop and unloading at workshop. Providing and installing transformer from its own temporarily to run the station till the damaged transformer is repaired and installed where standby not available
184Draining of Transformer oil in barrels, dismantling of top cover and extracting out assembly using chain pulley block and tripod and checking for fault.
185Reconditioning of LV Aluminum coilper kg
186Providing and fitting of HV leg coil Aluminium SE (per Kg)
187Providing and fitting of HV leg coil Aluminium DPC(per Kg)
188Providing and fitting of LV leg coil Aluminium DPC (per Kg)
189Providing & fitting of HV bushing
190Providing& fitting of LV bushing
191Providing& fitting of HV bush rod (metal part)per rod
192Providing& fitting of LV bush rod (metal part) per rod
193Providing& fitting of gasket set
194Providing& fitting of tapping switch with handle
195Providing & fitting of LT terminal plate
196Providing & fitting of Oil drain valve
197Providing & fitting of core laminations per Kg
198Providing& fitting of sundry items
199Heat treatment of repaired transformer
200Arresting of oil leakages if any by way of welding etc.
201Painting of transformer body
202Silica Gel breather
203Assembling of transformer and lowering into the tank using chain pulley block and tripod. Assembling of top cover thereof and filling of transformer oil after dehydrating.
204Loading of transformer into Mechanical transport using crane / skilled and un-skilled labour using tools and tackles and carriage to the site of work (For Urban areas). Mounting the transformer on poles/ platform with the help of crane / skilled and un-skilled labour using tools and tackles after dismounting the temporarily installed transformer
205Making of LT side cable connections as well as HT side cable connections and charging the transformer on no load conditions and thereafter checking on full load conditions.
206Providing and filling of transformer oil for topping (per litre)
207Providing & fitting of Lighting arrestor station type
208Providing & fitting of Lighting disc insulator with accessory polymer type
209Providing & fitting of Lighting pininsulator with pin polymer type
210Providing & fitting of Lighting AB switch 400Amp with handle operated.
211Providing & fitting of Lighting AB switch 200Amp with handle operated.
212Providing & fitting of horn gap DO switch
213Providing & fitting of Prodigy meter
214Providing & fitting of chemical earthing
215Providing & Fixing of Aluminum unarmored cable 1x120 Sq.mm
216Providing & Fixing of Aluminum narmoured cable 1x185 Sq.mm
217Road lighting network
218Providing & fitting with LED fitting 60/65 Watt along with allied Nipple for fixing of LED Fitting with wiremesh protection etc.
219Providing and fitting of MCB/ SPN installed for controlling of Road lighting Network of following
220SPN 32Amp
221TPN MCB 32Amp.
222Supply and fixing of dust and weather proof gasketted 250mm x 250mm x 200 mm deep cable looping box (nominal) size made out of 18 SWG fitted with pole with the help of 2 Nos. MS clamp (25x3mm) thick flat strip of suitable size with nuts and bolts. Complete with hinged cover locking L-Key/Nut Bolts type, earth studs suitable for poles mounted including supply and fixing of 6A MCB SP, MCB carrier and 4-way 63A terminal block fixed on suitable size and suitable for receiving PVC armoured cable complete with connections and painting etc.
223Providing and fittingof connection strip 63Amp 4pole heavy duty
224Providing & Fixing of prodigy meter
225Providing and fitting of SP MCB 6Amp. in existing connection box
226Repairingof existing 150/160 Watt LED light
227Providing and fitting of connection wire 2x1.5 sq mm in steel tubular pole.
228Fabrication, Supplying and fixing of 40mm dia MS pipe (Medium Class) bracket for mounting LED Street light fitting on pole at appropriate place including bending to required shape at 105 degree, 2 nos 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting to clamps with primer and finish paint etc as required complete Job.
229Providing and fitting of contractor MNX 9Amp. For timer
230Providing and fitting Solar/Quartz timer
231Cables of following sizes
232Providing & laying of Aluminum armored in ground 2.5feet below the ground level along with HDPC pipe 40mm Dia of Following sizes:-
2332x10 Sq.mm
2344x10Sqmm
2354x16Sqmm
2364x25 Sqmm
2374x35 Sqmm
2383.5x50Sqmm
239Internal Electrification
240Providing & fixing fall ceiling light 6/7 watt
241Providing & fixing fall ceiling light 9/10 watt
242Providing & fixing fall ceiling light 12 watt
243Providing & fixing LED tube light complete fitting 20 watt
244Providing & fixing LED bulb 9 watt
245Providing & fixingmodular switch 5/6Amp
246Providing & fixingmodular switch 15/16Amp
247Providing & fixingmodular socket 5/6Amp
248Providing & fixing modular socket 15/16Amp
249Providing & fixingmodular bell push
250Providing & fixingFan dimmer
251Providing & fixing modular plate 2 module
252Providing & fixing modular plate 3 module
253Providing & fixingmodular plate4module
254Providing & fixingmodular plate 6 module
255Providing & fixingmodular plate 12 module
256Providing & fixingSPN 32 amp in existing DB
257Providing & fixingSP 6 to 32 amp in existing DB
258Providing & fixingTPN 32 amp in existing DB
259Providing & fixingmodular plate 6 module
260Providing & fixingof following size single core copper wire in existing conduit.
2611x1.5 sqmm
2621x2.5 sqmm
2631x4 sqmm
2641x6 sqmm
265Providing & fixingCeiling fan 1200mmbase model
266Providing & fixingexhaust fan 300mm
267Providing & fixingInverter 1000VA
268Providing & fixingInverter 2000VA
269Invertor Battery 160 AH
270Servicing of window/spilt AC
271Water distribution system
272Providing & laying of GI pipe, complete with fitting in ground including trench & refilling the same.
27340mm Dia
27450mm Dia
27565mm Dia
27680mm Dia
277100mm Dia
278Providing & laying of GI Elbow of following sizes:-
27940mm Dia
28050mm Dia
28165mm Dia
28280mm Dia
283Providing & laying of GI Socket of following sizes:-
28440mm Dia
28550mm Dia
28665mm Dia
287100mm Dia
288Providing & fixing of MS flange of following sizes:-
2892 inch
2902.5 inch
2913 inch
2924 inch
2935 inch
294Providing & fixing Sluice Valvecast Iron (Heavy Duty)
29550mmǾ
29665mmǾ
29780mmǾ
298100mmǾ
299125mmǾ
300150mmǾ
301Providing & fixing NRV cast Iron (Heavy Duty)
30250mmǾ
30365mmǾ
30480mmǾ
305100mmǾ
306125mmǾ
307150mmǾ
308Repairing of cast Iron valve with finishing and polishing
30950mmǾ
31065mmǾ
31180mmǾ
312100mmǾ
313125mmǾ
314150mmǾ
315Jointing of MS/GI pipe 50mmdia to make leak proof
31650mmǾ
31765mmǾ
31880mmǾ
319100mmǾ
320125mmǾ
321150mmǾ
322Providing and fittingof short bend of following sizes
32380mmǾ
324100mm
325150mm
326Providing and fittingof Long bend of following sizes
32780mm
328100mm
329150mm
330Providing and fittingPuncher Roll to make leak proof connection
331Adhesive Tape

AI Tender Summary

OUR REF NO 44460970
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 31-08-2024
Authority
Authority Name Small Industries Development Corporation Limited
Work Description Tender For Annual Operation And Maintenance Of Existing Infrastructure Comprising Of Electromechanical Equipments Internal External Electrical System In Jksidco Managed Industrial Complexes Of Jammu Division-- 1 Complete rewinding of following submersible Motors including rebate of old material. 2 5 HP Capacity 3 7.5 HP Capacity 4 10 HP Capacity 5 12.5HP Capacity 6 15 HP Capacity 7 17.5 HP Capacity 8 20 HP Capacity 9 22.5 HP Capacity 10 25 HP Capacity 11 Complete rewinding of horizontal Squirrel Cage Motors High Speedtype including rebate of old material 12 5 HP Capacity 13 7.5 HP Capacity 14 10 HP Capacity 15 Repair to 5/7.5HP/10HP capacity motor by way of replacement of bearing at DE and NDE and assembling of motor. 16 Repair to 5/7.5HP/10HP capacity motor by way of welding, turning, polishingof shaft , sleeve to end covers and assembling of motor etc. 17 Disconnecting the electrical connection, disengaging the pump motor set from base frame , making alignment, all electrical connection and testing therof. 18 Loading of motor pump set into mechanical transport and carriage to workshop and unloading thereof. Loading the motor pump set into mechanical transport and carriage to site and unloading thereof by using skilled/unskilled labour and other tools and tackles 19 Up to 10 Km 20 Above 10Km upto 15Km 21 Loading of damaged Submersible Motor (V4) from site of work by way of head load carriage to Mechanical Transport and carriage back to site of work after repairing and unloading at site up to 10KM 22 Loading of damaged Submersible Motor (V6) from site of work by way of head load carriage to Mechanical Transport and carriage back to site of work after repairing and unloading at site up to 10KM 23 Submersible Pump V4 to V8 24 Disconnecting of power supply and testingof pump at site 25 Dismantling of submersible pump set at workshop and checking for its replacement of damaged parts. 26 Providing and fitting of new pump shaft 27 Reconditioning of pump shaft by way of welding, turning and polishing to actual size, making of key way 28 Providing and fitting of new cast iron impeller. 29 Reconditioning of impeller by way of welding, turning and polishing to the actual size. 30 Providing and fitting of new Neck Ring. 31 Providing and fitting of Shaft Sleeve. 32 Providing and fitting of Coupling with key 33 Providing and fitting of Bowl Bush 34 Providing and fitting of NRV Bowl. 35 Providing and fitting of Tee Bolts/per piece 36 Providing and fitting of Stud fasting ring with studs upper and lower and circlip lock. 37 Providing and fitting of Diffuser. 38 Providing and fitting of thrust bearing / thrust pad set 39 Assembling of Pump and then coupling with motor with proper alignment. Testing in test pit at workshop. 40 Providing and fitting of copper submersible cable 3 core along with thimbles 41 2.5 Sqmm 42 4Sqmm 43 6Sqmm 44 10Sqmm 45 16Sqmm 46 Extraction out of Submersible Motor pump set 47 Extraction out2.5 inch dia to 4 inch dia column pipes from tube by way of Disconnecting of Power connections from starter panel, disengaging from delivery bend and extracting out Submersible Pump Set complete along with column pipes by hoisting chain pulley block at Tube well, stacking of column pipes and Submersible cable properly. 48 Column pipes 0 to 10 Nos 49 Column pipes 10 to 20 Nos 50 Loweringof Submersible Motor pump set 51 Lowering of2.5 inch dia to 4 inch dia column pipes in Tube well byMaking of cable connection of motor with Submersible cable after dressing cable ends properly. Making of each joint water proof. Lowering of Submersible Pump Set complete along with column pipes and submersible cable with providing & fitting of jointing material and nuts and bolts. Making of connections to the starter panel 52 Column pipes 0 to 10 Nos 53 Column pipes 10 to 20 Nos 54 Star Delta control panels for Submersible pump set 55 Disconnection ofincomingPowerconnectionfrommainswitch /MCCB/Voltage Stabilizer and checking of fault. Making of temporary arrangement for running of pumpingmachinery 56 Providing and fittingof Damaged Contactor of following ratings 57 MNX 25 Amp 58 MNX 45 Amp 59 MNX 50 Amp 60 MNX 70 Amp 61 MNX 95 Amp 62 MNX 110 Amp 63 Providing and fittingof Damaged Kit of following rating contactors 64 MNX 25 Amp. 65 MNX 45 Amp. 66 MNX 50 Amp. 67 MNX 70 Amp. 68 MNX 95 Amp. 69 MNX 110 Amp. 70 Providing and fittingof Damaged coil of following rating contactors 71 MNX 25 Amp. 72 MNX 45 Amp. 73 MNX 50 Amp. 74 MNX 70 Amp. 75 MNX 95 Amp. 76 MNX 110 Amp. 77 Providing & Fitting of Auxiliary block 78 Providing & Fitting of Aluminum Bus Bar 79 Providing & Fitting of damaged over load relay & P/F new overload Relay 80 Providing & Fitting of damagedundervolt relay&P/Fnew relay 81 Providing & Fitting of single phase preventer ( L&T) 82 Providing & Fittingof DamagedMCCB 83 63 Amp 4pole 16KA 84 100 Amp 4pole 16KA 85 160Amp 4pole 16KA 86 200 Amp 4pole 36KA 87 250 Amp 4pole 36KA 88 400 Amp 4pole 50KA 89 630 Amp 4pole 50KA 90 Making of incomingPowerconnectiontomainswitch/MCCB/Servo Stabilizer and checking on full load at site 91 Control Star delta panel up 15 to 100 Amp. 92 Chargesforminorrepair/servicingofLTControlPanel including minorparts like meters, indicators , timers etc 93 Providing /fitting of circuit wiring 94 Providing /fitting of voltmeter Analog 95 Providing /fitting of amp meter Analog 96 Providing /fitting of Amp selector switch 97 Providing/ Fitting ofdigital Volt meter 98 Providing / Fitting of digital Amper meterCT operated 99 Providing /fitting of volt selector switch 100 Providing /fitting of Push Button on/off 101 Providing /fitting of indicator lamps R/4/B 102 Providing /fitting of star delta timer 103 Providing /fitting of terminal plate 104 Providing /fitting of quartz timer 105 Providing /fitting of delay timerProviding /fitting of delay timer 106 Providing /fitting of power wiring 107 Providing /fitting of thermal overload relay 108 Providing /fitting of bus bar 109 Providing /fitting of fuse link 110 Providing /fitting of fuse holder suitable for bolted fuse link 111 Servo Stabilizer 25 to 50 KVA Capacity 112 Rewinding of copper Coil & fitting etc at site. 113 Providing & Fitting of Dimmer coil 60Amp. 114 Providing & Fitting of Change Over Switch 100 ampere 115 Providing & Fitting of Change Over Switch 100 ampere 116 Providing & Fitting of digital Control card 117 Providing & Fitting of carbon brushes 118 Providing & Fitting of moving arm 119 Providing & Fitting of RC circuit 120 Providing & Fitting of toggle switch for auto /manual 121 Providing & Fitting of CT 100/5A 122 Providing & Fitting of limit switch 123 Providing & Fitting of gear wheel 124 Providing & Fitting of Indicator 125 Providing & Fitting of Selector Switch 126 Providing & Fitting of Ampere meter 127 Providing & Fitting of Voltmeter 128 Fresh Transformer Oil per litre 129 Providing & Fitting of Nut Bolts 130 Complete power wiringwith thimbling 131 Complete top panel wiringwith thimbling 132 Disconnecting of power connection of the servo Stabilizer, dismantling of stabilizer by unscrewing nut bolts. Extracting out of stabilizer coil structure by mounting of chain pulley block with the help of manual skilled labour. 133 Distribution Transformers 134 63KVA Capacity Transformer 135 Disconnecting of distribution transformer HT links and HT/ LT side cables. Dismounting from poles/platform using crane / skilled and un-skilled labour using tools and tackles, loading in Mechanical transport and carriage to workshop and unloading at workshop. Providing and installing transformer from its own temporarily to run the station till the damaged transformer is repaired and installed where standby not available 136 Draining of Transformer oil in barrels, dismantling of top cover and extracting out assembly using chain pulley block and tripod and checking for fault. 137 Reconditioning of LV Aluminium coilper kg 138 Providing and fitting of HV leg coil Aluminium SE (per Kg) 139 Providing and fitting of HV leg coil Aluminium DPC(per Kg) 140 Providing and fitting of LV leg coil Aluminium DPC (per Kg) 141 Providing & fitting of HV bushing 142 Providing& fitting of LV bushing 143 Providing& fitting of HV bush rod (metal part)per rod 144 Providing& fitting of LV bush rod (metal part) per rod 145 Providing& fitting of gasket set 146 Providing& fitting of tapping switch with handle 147 Providing & fitting of LT terminal plate 148 Providing & fitting of Oil drain valve 149 Providing & fitting of core laminations per Kg 150 Providing& fitting of sundry items 151 Heat treatment of repaired transformer 152 Arresting of oil leakages if any by way of welding etc. 153 Painting of transformer body 154 Silica Gel breather 155 Providing & Fitting of fresh T-oil 156 Assembling of transformer and lowering into the tank using chain pulley block and tripod. Assembling of top cover thereof and filling of transformer oil after dehydrating. 157 Loading of transformer into Mechanical transport using crane / skilled and un-skilled labour using tools and tackles and carriage to the site of work (For Urban areas). Mounting the transformer on poles/ platform with the help of crane / skilled and un-skilled labour using tools and tackles after dismounting the temporarily installed transformer 158 100KVA Capacity Transformer 159 Disconnecting of distribution transformer HT links and HT/ LT side cables. Dismounting from poles/platform using crane / skilled and un-skilled labour using tools and tackles, loading in Mechanical transport and carriage to workshop and unloading at workshop. Providing and installing transformer from its own temporarily to run the station till the damaged transformer is repaired and installed where standby not available 160 Draining of Transformer oil in barrels, dismantling of top cover and extracting out assembly using chain pulley block and tripod and checking for fault. 161 Reconditioning of LV Aluminum coilper kg 162 Providing and fitting of HV leg coil Aluminium SE (per Kg) 163 Providing and fitting of HV leg coil Aluminium DPC(per Kg) 164 Providing and fitting of LV leg coil Aluminium DPC (per Kg) 165 Providing & fitting of HV bushing 166 Providing& fitting of LV bushing 167 Providing& fitting of HV bush rod (metal part)per rod 168 Providing& fitting of LV bush rod (metal part) per rod 169 Providing& fitting of gasket set 170 Providing& fitting of tapping switch with handle 171 Providing & fitting of LT terminal plate 172 Providing & fitting of Oil drain valve 173 Providing & fitting of core laminations per Kg 174 Providing& fitting of sundry items 175 Heat treatment of repaired transformer 176 Arresting of oil leakages if any by way of welding etc. 177 Painting of transformer body 178 Silica Gel breather 179 Providing & Fitting of fresh T-oil 180 Assembling of transformer and lowering into the tank using chain pulley block and tripod. Assembling of top cover thereof and filling of transformer oil after dehydrating. 181 Loading of transformer into Mechanical transport using crane / skilled and un-skilled labour using tools and tackles and carriage to the site of work (For Urban areas). Mounting the transformer on poles/ platform with the help of crane / skilled and un-skilled labour using tools and tackles after dismounting the temporarily installed transformer 182 250KVA Capacity Transformer 183 Disconnecting of distribution transformer HT links and HT/ LT side cables. Dismounting from poles/platform using crane / skilled and un-skilled labour using tools and tackles, loading in Mechanical transport and carriage to workshop and unloading at workshop. Providing and installing transformer from its own temporarily to run the station till the damaged transformer is repaired and installed where standby not available 184 Draining of Transformer oil in barrels, dismantling of top cover and extracting out assembly using chain pulley block and tripod and checking for fault. 185 Reconditioning of LV Aluminum coilper kg 186 Providing and fitting of HV leg coil Aluminium SE (per Kg) 187 Providing and fitting of HV leg coil Aluminium DPC(per Kg) 188 Providing and fitting of LV leg coil Aluminium DPC (per Kg) 189 Providing & fitting of HV bushing 190 Providing& fitting of LV bushing 191 Providing& fitting of HV bush rod (metal part)per rod 192 Providing& fitting of LV bush rod (metal part) per rod 193 Providing& fitting of gasket set 194 Providing& fitting of tapping switch with handle 195 Providing & fitting of LT terminal plate 196 Providing & fitting of Oil drain valve 197 Providing & fitting of core laminations per Kg 198 Providing& fitting of sundry items 199 Heat treatment of repaired transformer 200 Arresting of oil leakages if any by way of welding etc. 201 Painting of transformer body 202 Silica Gel breather 203 Assembling of transformer and lowering into the tank using chain pulley block and tripod. Assembling of top cover thereof and filling of transformer oil after dehydrating. 204 Loading of transformer into Mechanical transport using crane / skilled and un-skilled labour using tools and tackles and carriage to the site of work (For Urban areas). Mounting the transformer on poles/ platform with the help of crane / skilled and un-skilled labour using tools and tackles after dismounting the temporarily installed transformer 205 Making of LT side cable connections as well as HT side cable connections and charging the transformer on no load conditions and thereafter checking on full load conditions. 206 Providing and filling of transformer oil for topping (per litre) 207 Providing & fitting of Lighting arrestor station type 208 Providing & fitting of Lighting disc insulator with accessory polymer type 209 Providing & fitting of Lighting pininsulator with pin polymer type 210 Providing & fitting of Lighting AB switch 400Amp with handle operated. 211 Providing & fitting of Lighting AB switch 200Amp with handle operated. 212 Providing & fitting of horn gap DO switch 213 Providing & fitting of Prodigy meter 214 Providing & fitting of chemical earthing 215 Providing & Fixing of Aluminum unarmored cable 1x120 Sq.mm 216 Providing & Fixing of Aluminum narmoured cable 1x185 Sq.mm 217 Road lighting network 218 Providing & fitting with LED fitting 60/65 Watt along with allied Nipple for fixing of LED Fitting with wiremesh protection etc. 219 Providing and fitting of MCB/ SPN installed for controlling of Road lighting Network of following 220 SPN 32Amp 221 TPN MCB 32Amp. 222 Supply and fixing of dust and weather proof gasketted 250mm x 250mm x 200 mm deep cable looping box (nominal) size made out of 18 SWG fitted with pole with the help of 2 Nos. MS clamp (25x3mm) thick flat strip of suitable size with nuts and bolts. Complete with hinged cover locking L-Key/Nut Bolts type, earth studs suitable for poles mounted including supply and fixing of 6A MCB SP, MCB carrier and 4-way 63A terminal block fixed on suitable size and suitable for receiving PVC armoured cable complete with connections and painting etc. 223 Providing and fittingof connection strip 63Amp 4pole heavy duty 224 Providing & Fixing of prodigy meter 225 Providing and fitting of SP MCB 6Amp. in existing connection box 226 Repairingof existing 150/160 Watt LED light 227 Providing and fitting of connection wire 2x1.5 sq mm in steel tubular pole. 228 Fabrication, Supplying and fixing of 40mm dia MS pipe (Medium Class) bracket for mounting LED Street light fitting on pole at appropriate place including bending to required shape at 105 degree, 2 nos 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting to clamps with primer and finish paint etc as required complete Job. 229 Providing and fitting of contractor MNX 9Amp. For timer 230 Providing and fitting Solar/Quartz timer 231 Cables of following sizes 232 Providing & laying of Aluminum armored in ground 2.5feet below the ground level along with HDPC pipe 40mm Dia of Following sizes:- 233 2x10 Sq.mm 234 4x10Sqmm 235 4x16Sqmm 236 4x25 Sqmm 237 4x35 Sqmm 238 3.5x50Sqmm 239 Internal Electrification 240 Providing & fixing fall ceiling light 6/7 watt 241 Providing & fixing fall ceiling light 9/10 watt 242 Providing & fixing fall ceiling light 12 watt 243 Providing & fixing LED tube light complete fitting 20 watt 244 Providing & fixing LED bulb 9 watt 245 Providing & fixingmodular switch 5/6Amp 246 Providing & fixingmodular switch 15/16Amp 247 Providing & fixingmodular socket 5/6Amp 248 Providing & fixing modular socket 15/16Amp 249 Providing & fixingmodular bell push 250 Providing & fixingFan dimmer 251 Providing & fixing modular plate 2 module 252 Providing & fixing modular plate 3 module 253 Providing & fixingmodular plate4module 254 Providing & fixingmodular plate 6 module 255 Providing & fixingmodular plate 12 module 256 Providing & fixingSPN 32 amp in existing DB 257 Providing & fixingSP 6 to 32 amp in existing DB 258 Providing & fixingTPN 32 amp in existing DB 259 Providing & fixingmodular plate 6 module 260 Providing & fixingof following size single core copper wire in existing conduit. 261 1x1.5 sqmm 262 1x2.5 sqmm 263 1x4 sqmm 264 1x6 sqmm 265 Providing & fixingCeiling fan 1200mmbase model 266 Providing & fixingexhaust fan 300mm 267 Providing & fixingInverter 1000VA 268 Providing & fixingInverter 2000VA 269 Invertor Battery 160 AH 270 Servicing of window/spilt AC 271 Water distribution system 272 Providing & laying of GI pipe, complete with fitting in ground including trench & refilling the same. 273 40mm Dia 274 50mm Dia 275 65mm Dia 276 80mm Dia 277 100mm Dia 278 Providing & laying of GI Elbow of following sizes:- 279 40mm Dia 280 50mm Dia 281 65mm Dia 282 80mm Dia 283 Providing & laying of GI Socket of following sizes:- 284 40mm Dia 285 50mm Dia 286 65mm Dia 287 100mm Dia 288 Providing & fixing of MS flange of following sizes:- 289 2 inch 290 2.5 inch 291 3 inch 292 4 inch 293 5 inch 294 Providing & fixing Sluice Valvecast Iron (Heavy Duty) 295 50mmǾ 296 65mmǾ 297 80mmǾ 298 100mmǾ 299 125mmǾ 300 150mmǾ 301 Providing & fixing NRV cast Iron (Heavy Duty) 302 50mmǾ 303 65mmǾ 304 80mmǾ 305 100mmǾ 306 125mmǾ 307 150mmǾ 308 Repairing of cast Iron valve with finishing and polishing 309 50mmǾ 310 65mmǾ 311 80mmǾ 312 100mmǾ 313 125mmǾ 314 150mmǾ 315 Jointing of MS/GI pipe 50mmdia to make leak proof 316 50mmǾ 317 65mmǾ 318 80mmǾ 319 100mmǾ 320 125mmǾ 321 150mmǾ 322 Providing and fittingof short bend of following sizes 323 80mmǾ 324 100mm 325 150mm 326 Providing and fittingof Long bend of following sizes 327 80mm 328 100mm 329 150mm 330 Providing and fittingPuncher Roll to make leak proof connection 331 Adhesive Tape
Basic Detail
Tender No E-NIT No 01 of 2024 25
Bidding Type Tender
Location
City jammu
State Jammu And Kashmir
Key Dates
Publish Date 27 Aug 2024
Submission Date 31 Aug 2024
Open Date 02 Sep 2024
Finance
Tender Value Ref. Documents
Tender Fee 1500
EMD 50000
Exemption Not Available
Document List
fdc2cb61-5e0a-4b6e-b8cb-541095bd5837.html
BOQ_740098.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 27, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2024
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Aug 31, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 02, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

fdc2cb61-5e0a-4b6e-b8cb-541095bd5837.html

xls

BOQ_740098.xls

pdf

Tendernotice_1.pdf

TenderDetail
Loading tenders