| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulatedcopper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulatedcopper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulatedcopper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulatedcopper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required |
| 7 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. |
| 8 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 9 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 10 | Supplying and fixing of 4 way (4+12), Double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. Make- Havells |
| 11 | Supplying and fixing 8 way, Double door single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 12 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts ,10KA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Sigle pole |
| 13 | Supplying and fixing 63 amp rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 14 | Providing and fixing 200 A, 16 KA,TPMCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 15 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. but with charcoal/ coke and saltas required. |
| 16 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 17 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 18 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as as required. |
| 19 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 20 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 21 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 22 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 23 | Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. |
| 24 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm (32mm) |
| 25 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.),insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply earthing etc, complete as required |
| 26 | Supplying, and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments of 3.5 x 35 sqmm size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. , Make - Havells/ Polycab/ KEI or equivalent. Detail cost for 100 Mtr |
| 27 | Supplying and fixing of 22 watt decorative ultra slim square profile LED lighting fixture with extruded polycarbonate bodyequivalent to Havells modelE-LITE LED PRIDE PLUS/NXT, LED Pride Plus NXT Batten 22 W 6500 K. Make - Havells/ Philips/ Bajaj/ Crompton |
| 28 | Providing and fixing 4 feet, 2 x 20 Watt CMRI certified IP 65 protected LED flameproof tube fixture, with LED tube, Including 2 Nos 20 watt tube rod and dismentaling the existing box type tube fitting. Complete in all respect. Crompton.Make- Havells/ Crompton/ Phillips etc. |
| 29 | Supplying and fixing of 3 star rating , 5 watt LED bulb having base of B-32 make Havells/philips/crompton |
| 30 | Supplying and fixing of 400 mm sweep, 230 volt, single phase wall fan metal body, having 5 nos blades, equivalanrt to Havells model Pentaforce. Make - Havells/ Bajaj/ Orient etc |
| 31 | Supply, installation, testing and commissioning of Fresh Air Exhaust Fans (PVC Body) single phase, ISI Marked ,250 mm sweep. Equivalent to Havells Ventil Air DX. Make Havells/ Crompton/ Havells/ usha ect. |
| 32 | Supplying and fixing of 100 watt LED security/ flood light new generation energy saving and environmental friendly long life LED flood light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover with IP66 protection. equivalent to Havells Centura Neo LED Flood Light 100 W 6500K. Make - Havells/ Phillips/ Crompton or equivalent |
| 33 | Supplying and fixing 40 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of Double pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make- Havells/ ABB/ Schneider etc as equivalent. |
| 34 | Add @1.0633 on DSR items for enhencement in GST rates |