Tender For Construction Of Awc At Pathra Under Nagari Gp Center No -213 (2Nd Call), 1 Earth work in excavation of foundation trenches or drains, in all sorts of soil ……. as required complete. 2 (a) Depth of excavation not exceeding 1.5 m. 3 Earthwork in filling in foundation trenches or plinth …… complete. 4 Filling in foundation or plinth by silver sand in layers not exceeding …… sand. 5 Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. 6 Cement concrete with graded stone ballast (40 mm size) excluding shuttering. Pakur variety 7 (b) 1:3:6 proporation 8 Ordinary cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size ) excluding shuttering and reinforcement, if any, in ground floor, as per IS codes. GROUND FLOOR 9 Reinforcement for reinforced concrete work in the all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial strightening and removal of loose rust (if necessary), cutting requisite length, hooking and binding to correct shape, placing in proper position chairs and spacers and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor / upto 4 m. JSW/ JSPL / SHYAM / SRMB /BMASL / ELECROSTEEL /SSL (GROUND FLOOR) 10 Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood plank of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (GROUND FLOOR) 11 Labour for Chipping of concrete surface before taking upPlastering work. 12 Brick work with 1st class bricks in cement morter (6:1) 13 (a) In foundation and plinth 14 Brick work with 1st class bricks in cement morter (6:1), in superstructure, GROUND FLOOR 15 125 mm thick Brick work with 1st class bricks in cement morter (4:1) GROUND FLOOR 16 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints ………. Where necessary. 20 mm thick plaster with 6:1 cement mortar. GROUND FLOOR 17 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints ………. Where necessary. 15 mm thick plaster with 6:1 cement mortar. GROUND FLOOR 18 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints ………. Where necessary. 10 mm thick plaster with 4:1 cement mortar. GROUND FLOOR 19 Neat cement punning …….. Etc. 20 A) Supplying fitting and fixing door frame with M.S. angle as per drawing & direction of required section.The holes for counter sunk machine screw & nuts will be such as to fit 8 to 10 mm Iron screw. The counter sunk nut to be welded . The nuts are to be welded after careful checking with screw.All welding spots should be properly filed or rounded smooth including cost of welding hinges for hinge cleats , lugs for hasp bolt, socket bolt etc. and necessary M.S. clamps of 25mm x 6mm flat 225mm long as per direction welded to the frame fitted and fixed in position excluding cost of concrete. 21 Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials. GROUND FLOOR 22 Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. 23 M.S or W.I ornamental grill or approved design joints continuously welded with M.S, W.I flats and bars for windows, railing etc. fitted and fixed with necessary screws and lugs in first floor. 24 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. 25 FLOOR 26 WALL 27 Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all otherincidental charges complete true to the manufacturers specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr]e)I(I) With application slurry @1.75 kg/ Sq.m, 20 mm sandcement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling withpigment. 28 Supplying and laying chequered tiles of any shade & of approved quality with (1:1½:3) cement concrete laid in panels or patterns as directed in pavement, footpath etc. including necessary underlay 25 mm thick [avg] cement mortar (1:3) complete in all respect with all labour and materials. [Using cement slurry @ 4.4 kg/Sq.m at back side and @2.4 kg/Sq.m for joint filling]Red Variety 29 Precast pierced concrete jally work as per design and manufacturers specification including moulding etc. with stone chips and necessary reinforcement shuttering complete including fitting, fixing in position in all floors.(b) 37.5 mm thick panels 30 Providing and fixing PVC Door Frame of size 50x47mm with a wall thickness of 5mm (± 0.2 mm) made out of single piece extruded PVC profile, with mitred cut joint sand joint with 2 nos. of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 mm x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40x20mm M.S. rectangular tube of 0.8 mm , including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. The doorframe to be fixed to the wall using 8 x100mm long anchorfasteners complete, all as per manufacturer‟s specification and direction of Engineer -in- charge. 31 Supplying, Fitting & Fixing 30 mm thick Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC “C” channel of size 30 mm th, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top &bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5 mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail. Paneling of 5 mm th. both side PVC sheet to be fitted in the M.S. frame welded/sealed to the styles &rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the “C” channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as per direction of Engineer-in-Charge. In ground floor. 32 Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surface by sand papering etc. 33 On Steel or other metal surface 34 Painting with best quality synthetic enamel paint of approved make and brand including smoothenig surface by sand papering etc. including using of approved putty etc. on the surface if necessary. 35 On Steel or other metal surface 36 Applying decorative cement based paint of approved quality after preparing the surface including scraping the same throughly (plastered or concrete surface) as per manufacturers specification [P.W.D Schedule page no.197, item no 15]. Ground floor External Surface, Two Coat. 37 Applying decorative cement based paint of approved quality after preparing the surface including scraping the same throughly (plastered or concrete surface) as per manufacturers specification [P.W.D Schedule page no.197, item no 15]. Ground floor internal Surface, Two Coat. 38 Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge in Ground Floor. (a) Slab Thickness 20 to 25 mm 39 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. 40 UPVC PIPE 75 MM Dia 41 UPVC FITTINGS PLAIN TEE 75 MM DIA 42 Bend 87.5, 75 MM Dia 43 Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:(iii) 100mm long x 10mm dia. bolt. 44 Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.v) 75mm. X 60mm. X 3.15mm 45 Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (b) With round base:(ii) 100 mm grip x 10 mm dia rod. 46 Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,PartI.Payment will be made separetly on the basis of actual height based on relevant I.S.Code. 47 Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. 48 Supplying, fitting and fixing bib cock or stop cock 49 Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) 50 20 MM 51 25 MM 52 32 MM 53 Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding P or S trap (excluding cost of concrete for fixing). 54 Supplying, fitting and fixing pillar cock of approved make.d) Polythene Piller Cock (EMCO / ATLAS or equivalent)(i) 15 mm 55 Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. 56 Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps. 57 Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer. 1000 LIT CAPACITY 58 Labour for hoisting plastic water storage tank. (i) Upto 1500 litre capacity. 59 Supplying, fitting and fixing towel rail with two brackets.b) Aluminium (i) 25 mm dia. and 450 mm long 60 Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver red as per I.S. 3438 / 1965 together with brass C.P. hinges. (i) 450 mm X 300 mm 61 Supplying, fitting and fixing soap holder.(a) PTMT (Prayag or equivalent) 62 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length(a) (c) 160 mm 63 Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets.(a) Sink(ii) 630 mm X 550 mm X 180 mm 64 Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes& fittings conforming to IS-15778: 2007(Q) Ball Valve 25 mm 65 Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete. 66 Wash basin vitreous china of approved make (without fittings) supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm wood blocks and C.I. brackets including two coats of painting of C.I. brackets. 67 Add for Electrification 68 Add for Submersible Pump 69 Add GST @ 18% 70 Add Cess @ 1%