Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-09-2024 | boqdescription | Other | 01-10-2024 |
| 2 | 20-09-2024 | Dateamendment | Date | 01-10-2024 |
| 3 | 04-09-2024 | Date | Date | 24-09-2024 |
| 4 | 30-08-2024 | Due Date Extended for tenders closing on 14-08-2024. | Admin Corrigendum Date Extend | 06-09-2024 |
| Sl. No. | Item Description |
| 1 | Labour only for attending day to day external/treated water supply complaints of all nature including grey water pipe leakage i.e leakage in water supply pipe lines, fitting/fixture, over flow of overhead tank, no water supply in supply tank/direct kitchen tap and taking out water from trenches during repair including write downthe complaints in complaint register complete all as specified and as directed. (Note 1 :- Any material required for attending complaints for rectification shall be measured and paid separately under respective item herein after) (Note 2 :- Quoted rates includes following other aspects as srl No. 3 (i) to 3 (x) below). |
| 2 | Labour only for attending of Electric supplycompliants of day to day maintenace of existing LT Panels including connecting electrical accessories / spares of water supply installation and electrical fitting & light, short circuits in Pump housecomplete all as specified and as directed.(Note 1 :- Any material required for attending complaints for rectification shall be measured and paid separately under respective item herein after) (Note 2 :- Quoted rates includes following other aspects as srl No. 3 (i) to 3 (x) below). |
| 3 | Notes for item No. 1.00 & 2.00 (i)The complaints shall be attended and the defects shall be rectified by a team of expert and experiencedelectrician/plumber as applicable assisted with adequate numbers of helpers complete all as specified and as directed. Minimum requirements of skilled and unskilled workers for whole contract period are as under:-(a) One plumber or fitter with one helper.(b) One Electrician or fitter with one helper.(ii) Requirement of additional workers if required for rectification of any complaint (occationally) will be provided by contractor on urgent requirement basis as directed by EIC without any extra cost. |
| 4 | (iii)The complaints shall be attended and defect shall be rectified within 04 hrscommencing from date and time of notifying the complaint failing which a penalty @ Rs 250/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor\"s dues. Contractorshall appoint suitable staff for receive and register of complaints received in person/through telephone/mobile and issue and control contractors stores andworkers will required to available within time daily at 0800 hrs to 2000 Hrs to receive and notify each complaint. Attendence register of workers daily basis will provided by contractor duly signed by JE E/M & Eng-in-Charge. |
| 5 | (iv)In case, after checking and attending the defect, it is not possible to rectify the defects within 08 hrs the facts shall be brought to the notice of Engineer-in -charge by the contractor /his rep . If Engineer -in-charge is satisfied with contractors view, no recovery will be made. |
| 6 | (v)While attending the complaint of water supply /Electric supply if earth work is required then the same shall be measured and paid seperately under respective item of Sch \"A\" . However no extra payments shall be made for dewatering. |
| 7 | (vi)Cutting of GI pipe in position and threading is also deemed to be included in the quoted unit rates (Fitting and fixtures will be measured and paid separetely under respective item of Sch A as supply only). |
| 8 | (vii)All T & P including safety gears required for attending the complaints shall be provided by the contracor. |
| 9 | (viii)The elecrician shall always be in possession of all Electrician tools , LT Megger, Earth tester , Multimeter , Crimping tool, insulation tape, Hand gloves etc required at site. |
| 10 | (ix)Old retrived materials, will be deposited by contractor to store yard of AGE (U) Water Supply No I and necessary RV attached with RAR / Final bill mentioning ledger number & page number.(x) All the fitting /fixtures as mention below item No 4 to 17.00 and 35 to 37.12 of BOQ shall be procured by contractor in one time and the same shall be kept with safe custory of Eng-in-charge store and issue RV to contractor. Piecmeal requirement of fixing of fittings as required at site will be issued by JE (E/M) through Baby indent. Proper register will maintained by contractor for daily consumption of materials consumed at site with showing debit complaint wise. The same register will be signed by JE (E/M) & Eng-in-Charge and produced with RAR/Final bill.(xi) First RAR will be submitted by contractor for material lying at site only. |
| 11 | (x) A BOO ordered for material procured by contractor and taken on charge through RV and complaint wise dockets will maintained and USR\"s duly vetted by AO GE (E/M) for procured materials issued for incorporation in work will be mentioned in BOO. BOO will concorn/approved by Accepting Officer in one time for complete materials to be consumed in work and if any balance quantity of material left with contractor the same will received back on credit USR\"s & kept on record. |
| 12 | Supply only GI Socket \"medium grade\" ISI Marked superior / standard of a make of following sizes :- |
| 13 | 15 mm bore |
| 14 | 20 mm bore |
| 15 | 25 mm bore |
| 16 | 40 mm bore |
| 17 | 50 mm bore |
| 18 | Supply only GI Elbow \"Medium grade\", ISI Marked superior / standard of a make of following sizes : - |
| 19 | 15 mmbore |
| 20 | 20 mm bore |
| 21 | 25 mm bore |
| 22 | 40 mm bore |
| 23 | 50mm bore |
| 24 | Supply only GI Union \"Medium grade\", ISI Marked superior / standard of a make of following sizes : - |
| 25 | 15 mmbore |
| 26 | 20 mm bore |
| 27 | 25 mm bore |
| 28 | 40 mm bore |
| 29 | 50 mm bore |
| 30 | Supply only \"GI Nipple\" of suitable length as required at site & ordered by EIC both end screwed \"Medium Grade\", ISI marked superior / standard of a make of following sizes: |
| 31 | 15 mmbore |
| 32 | 20 mm bore |
| 33 | 25 mm bore |
| 34 | 40mm bore |
| 35 | 50mm bore |
| 36 | Supplyonly GI Reducing socket \"medium grade\" ISI marked superior / standard of a make of the following sizes :- |
| 37 | 20 mm x 15 mm bore |
| 38 | 25 mm x 20 mmbore |
| 39 | 50 mm x 40 mmbore |
| 40 | 25 mm x 15 mmbore |
| 41 | Supply onlyGI Solid plug heavy duty ISI Marked superior / standard of a make of following sizes : - |
| 42 | 15 mm |
| 43 | 20 mm |
| 44 | 25 mm |
| 45 | 40 mm |
| 46 | 50 mm |
| 47 | Supply onlyGI Tee \"Medium grade\" ISI Marked superior / standard of a make of following sizes : - |
| 48 | 15mm x 15mm x 15mm |
| 49 | 20 mm x 20 mm x 15 mm |
| 50 | 20 mm x 20 mm x 20 mm |
| 51 | 25 mm x 25 mm x 25 mm |
| 52 | 25 mm x 25 mm x 15 mm |
| 53 | 40 mm x 40 mm x 40 mm |
| 54 | 50 mm x 50 mm x 50 mm |
| 55 | 50 mm x 50 mm x 25 mm |
| 56 | Supply onlyPTMTfloat valve of sizes as under, with epoxy coated aluminium rod 250mm length and high density plastic ball of 150mm dia complete all as specified and as directed:- |
| 57 | PTMT float valve, 15 mm bore |
| 58 | PTMT float valve, 20 mm bore |
| 59 | PTMT float valve, 25 mm bore |
| 60 | PTMT float valve, 50 mm bore |
| 61 | Supply only Gun metal gate valve, with iron wheel head screwed both ends for iron pipe as per IS-778 complete all as specified and as directed of following sizes:- |
| 62 | Gun metal gate valve, 15 mm bore |
| 63 | Gun metal gate valve, 20 mm bore |
| 64 | Gun metal gate valve, 25 mm bore |
| 65 | Gun metal gate valve, 40 mm bore |
| 66 | Gun metal gate valve, 50 mm bore |
| 67 | Labour only for run lead joint by using new lead and new spun yarn including jointing material for CI/DI pipes of following size/bore. (Note: Run lead and spun yarnused for repairing the joints following sizes of pipe will be measured and paid seperately under respective items as supply only.) |
| 68 | 80 mmbore |
| 69 | 100mmbore |
| 70 | 150mmbore |
| 71 | Supply only pig bar (Raw lead) for use in work complete all as specified and as directed. |
| 72 | Supply only spun yarn best quality for use in work complete all as specified and as directed. |
| 73 | Supply only Nuts ,Bolts and Washers 25 to 150 mm long of 6 to 20 mm dia complete all as specified and as directed. |
| 74 | Supply only 15 mm bore Bib tap of PTMT, any tint, high pressure screwed for male/ female threaded, forpipe of size 15 mm bore complete all as specified and as directed. |
| 75 | Taking up old GI steel tubing of following sizes with connections from Trenches/floors/walls including cleaning for refixing or removal complete all as specified and as directed.Note :- (i) Excavation & earth work shall be measured & paid separetely.(ii) Old U/s GI pipe & fittings shall be taken under charge of demolition / salvage register with mentioning page number in credit materials BOO.) |
| 76 | 15 mm bore |
| 77 | 20 mm bore |
| 78 | 25 mm bore |
| 79 | 40 mm bore |
| 80 | 50 mm bore |
| 81 | 80 mm bore |
| 82 | Supply & Laying ofGI pipe \"medium grade\" ISI mark including all fittings in old/new positions in trenches/wall/floor complete and making good the distributed surfaces as per existing as directed of following sizes. (Note:- Excavation and earth work will be measured and paid separately.) |
| 83 | 15 mm bore |
| 84 | 20 mm bore |
| 85 | 25 mm bore |
| 86 | 40 mm bore |
| 87 | 50 mm bore |
| 88 | 80 mm bore |
| 89 | Taking up CI/DI Pipe of following sizes including all fittings) with spigot and socketed endsand lead tyton joints includingburning out lead jointsand recovering lead and including cleaning for refixing or removal, making good disturbed surface complete all as specified and as directed.(Note:- (i) Excavation & earth work shall be measured & paid separetely.(ii) Layout plan for laying of DI pipe shall be given by EIC in writing.(iii) DI pipe whole quantity of tender shall be procured by contractor for payment in 1st RAR as material lying at site.(iv) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 90 | 80 mm bore |
| 91 | 100 mm bore |
| 92 | 150 mm bore |
| 93 | 200 mm bore |
| 94 | Supply, layingjointing,testingDIpipe with class-K-7 spigot socketed ends , conforming to IS-8329 laid in trenches including providing route indicators of suitable height and laying at spacing of @ 50m center to center at GL mentioning name of contractor, date of execution & CA No with name of workof the following sizes complete all as specified and directed by Engineer-in-Charge.(Note : (i) Tyton Joint, Excavation & earth work shall be measured & paid separetely.(ii) Layout for DI Pipe shall be approved by GE before commencement of work.(iii) DI pipe whole quantity of tender shall be procured by contractor in one time and the same will be paid in 1st RAR as material laying at site.(iv) Cost of route indicator shall be deemed included in quoted unit rate. |
| 95 | 80 mm bore |
| 96 | 100mmbore |
| 97 | 150mm bore |
| 98 | 200mm bore |
| 99 | Material & Labour for rubber gasket joint including jointing material for CI/DI Pipe of following sizes complete all as specified and as directed . |
| 100 | 80 mm bore |
| 101 | 100 mm bore |
| 102 | 150 mm bore |
| 103 | 200 mm bore |
| 104 | Material and labour for DI specials like bends, tapers any type any radius and angle, Tee pieces single branch `Y\" junction, double branch, cross (all sockets or socket and spigot) collars, DI connecting pieces one end flanged and other end spigot/socket, reducers/bell mouth pieces one end flanged and other end tapering as bell mouth for the size up to 250 mm dia bore complete all as specifed and directed.(Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 105 | Supplying, laying, jointing, welding and testing MS Pipe (Heavy class\"C\") IS : 1239/3589, of followiing sizes laid in trenches or in Horizontal/Vertical/inclined position orlaying on floors for connectionsfor suction, to header andconnected to out going water main CI/DI pipe line, forfollowing size including taking out the old unserviceable pipes :- Note:- (i) MS Flangesincl fabrication work will be measured and paid separately.(ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 106 | 80 mm dia |
| 107 | 100 mm dia |
| 108 | 150 mm dia |
| 109 | Suuply & fixing including jointing & testing of cast Iron Sluice Valve of following size ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body,Confirming to IS 14846, having stainless steel spindle with cast iron operation wheel at top including taking out unserviceable sluice valve complete all as specified and as directed . (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.(ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in of sluice valve weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 110 | 80 mm dia |
| 111 | 100mm bore |
| 112 | 150mmbore |
| 113 | 200mmbore |
| 114 | Supply and Fixing in replacement of CI Foot valve offollowing size , Flanged ends, Swing type opration with rubber sheet as per IS-4038 including taking out unserviceable of following sizes complete all as specified and directed by Engineer-in-Charge. (Note :- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this items.(ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 115 | 80 mmbore |
| 116 | 100 mmbore |
| 117 | 150mmbore |
| 118 | M&L applying painting with two coat of synthetic enamel paint as per existing pattern on pipe surface/header connectionincluding preparation of surfaces by scratching and removing the rust, applying one coat red oxide primer complete all as specified and as directed. |
| 119 | M&L removing weeds and wild grass inside the installations using chemical spray and trimming trees and unwanted plants using petrol operated Tree/Grass cutting tools and dressing of the surface by scrapping high patches and filling low patches with the scrapping soil to give an even and neat look to the site and disposing off all the unwanted grass, bushes and debris complete all as specified and directed by the Engineer-in-Charge.(Note:- Photographs of location date wise where weeds and wild grass of istallations required to be removed before execution and after completion of work will enclosed with RAR for payment purpose. If photographs not found attached with RAR, the same payment will not be allowed). |
| 120 | M&L openning of gland packing coupling and removing the unserviceable gland rope from Sluice valve of size 80 to 300 mm dia and supply & fixing the new gland rope all as per existing size gland rope complete all as specified and directed. |
| 121 | M&L Decorative ultra slim round profile LED lightning fixture 20W,6000K, with extruded polycarbonate environmental friendly energy efficient incl taking down old unserviceable light fitting complete all as specified and as directed.(Note :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 122 | Supply and fixing in replacement 45 watt LED street light New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07including making connections with providing new GI pipe 0.6mtr on angle bracket fixing on wall and connectng to ceiling rose with apropriate wirecomplete all as specified and directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 123 | Excavation in trenches not exc 1.5 M wide and not exc 1.5 M indepth for pipe line, etc in soft/ loose soil getting out and levelling of bottom surface to required level all as specified and as directed. |
| 124 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed. |
| 125 | Removing excavated material to a distance not exc 50 m and depositing where directed not exc 1.5 meters above the starting point complete all as specified and as directed. |
| 126 | Labour work required for taking out suction pipe from sump of any capacity 80 mm to 200 mm size screw/ flanged typeand relowering after refixing in position the same duly cleaned / minor repair if any required such as replacement of rubber gasket / lifting bolts & nuts including making thread for the suction pipes off sizes etc complete all as specified and directed by Engineer - in - charge |
| 127 | Testing of drinking water being collected from local source (bore wells/shallow wells/under ground sumps) in the area under AGE(U) W/S No I and submission of detailed test reqport to the office of Engineer-in-Charge.(a)Collection of water from different sources of water ie Sump, bore wells& shallow wells in sterilized bottle for testing of water of different sources from Govt Approvedlaboratory as mentioned in PS.(b)Carrying out minimum essential testing of water as per IS 10500-1991 mandatory for chemical colour, odour, taste, turbidity, Lead, PH value TDS total hardness, iron, chloride, fluride and residual free chlorine and Bacteriological total Collie from organisms per 100 ml (MPN) and E Collie in 100 ml) and submission the test report to EIC and after ward the same will be submit by EIC to AO with their specific recommendation regarding suitability of water for drinking purpose. |
| 128 | Note :- Rate quoted shall deemed to be included for: -(i) Cost of sterilized bottle as required.(ii)To and FRO transportation charges for collection of samples from different source(sump/bore well/shallow wells)(iii) Testing lab shall be approved by GE. Frequancy of testing of water from each source will be decided by EIC and \"test reports\" will directly submitted by lab to EIC through \"DAK\"). |
| 129 | Supply only switch /sockets of approved make of following items :(Note :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 130 | Switch piano flush type 5/6 Amps singal pole one way, 240 volts |
| 131 | Switch piano flush type 15/16 Amps singal pole one way, 240 |
| 132 | Socket outlet 2 in 1, 3/5 pin, 5/6 Amps240 volts |
| 133 | Socket outlet 2 in 1, 3/5 pin, 15/16 Amps240 volts |
| 134 | Switch socket combination 2 in 1, 3/5 pin, 5/6 Amps240 volts |
| 135 | Switch socket combination 2 in 1, 3/5 pin, 15/16 Amps240 volts |
| 136 | MCBSP 10 to 32 Amp, 240 volts \"B\" curve |
| 137 | MCB SPN40 Amp , 240 volt \"B\" curve |
| 138 | MCB TP63 Amp , 415 volt \"B\" curve |
| 139 | PVC insulation tape role 15mm wide, 20 Running meter long(white/black) best quality. |
| 140 | PVC insulated multistranded copper conductor wire of size 1.5 Sqmm, 1100 volts grade FRLS type. |
| 141 | PVC insulated multistranded copper conductor wire of size 2.5 Sqmm, 1100 volts grade FRLS type. |
| 142 | Suppply & fixing in replacementMCCB 100Amps, 3 pole, breaking capacity25 kA, connection complete all as specifed and directed |
| 143 | Suppply & fixing in replacementMCCB 63Amps, 3 pole , breaking capacity16 kA,connection complete all as specifed and directed |
| 144 | Suppply & fixing in replacementanalog type time switch FM 1/Quartz daily 240 volts , AC, 50 Hz code J 6107B 204connection complete all as specifed and directed.(Note for item No 38 to 40:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 145 | Supply, installation, commissioniong and testing of soft starter suitable for motor capacity 15HP 3 phase 415 Volts 50 Hz with Compact design, with built-in bypass contactor, Essential motor protection, Selectable soft starting profiles, Flexible communication options, Excess start time settling including taking down old starter and related accessories and deposited to MES store yard complete all as specified and directed.(Note:- Old U/s soft starter material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 146 | M&L incls fabrication of glow ditribution diagram of pipeline network including showing of all Pumps, Headers, Valves and pipeline of different sizes etc comprising of printing of complete distribution diagram on Vinyl sheet, weather proof and monolithiely attached the same on bakelite sheet min 3 mm thick of size 150\"mm x 240mm\" x 100\"mm thick fixed on MS frame of similar size made out of square MS Pipe of size 25 mm x 25 mm with proper back lighting for proper illumination and proper colour legends for all the feeders, pumps and valves with proper circuit controlled wiring of suitable size and one top plug 3-Pin 5 Amp including fixing the same at the pump house wall and including all fixing material required complete all as specified and directed. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 147 | Supply, Installation Testing & Commissioning of ULTRASONIC LEVEL SENSORS Water Level Sensor for underground tanksuitable forup to 6 meter water level depth of U/G sump, with dead band of less than 0.6meter, IP66 protection, accuracy of 0.25% of F.S. and RS485 Modbus RTU communication protocol, Capable for working in ambient temperature of 0 degree Centigrade to 75 degree Centigrade, non-condensing at 25 degree Centigrade and humidity up to 95% with response time of less than 1 sec with 230VAC to 24VDC, 50Hz power supply, LCD display type, vertical type mounting on top of OHTswith all connectionsand fixing includingclamp, nut-bolt etccomplete all asspecified and as directed.(Note:- Old U/s water level sensor material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 148 | Supply and fixing in replacement 3 pole power contactor ML-1.5, 25 Ampssuitable for fixing in existing panel complete all as specified and as directed. |
| 149 | Supply and fixing in replacement 3 pole power contactor ML-2, 32-40 Ampssuitable for fixing in existing panel complete all as specified and as directed. |
| 150 | Supply and fixing in replacement of over load relay, type ML 1.5 relay, range 10-16 Amp complete all as specified and as directed. |
| 151 | Supply and fixing in replacement of over load relay, typeML-2 starter range 9-14 Amps complete all as specified and as directed. |
| 152 | Supply and fixing in replacement of over load relay, typeML-2 starter range 13-21 Amps complete all as specified and as directed. |
| 153 | Supply and fixing in replacement of over load relay, typeML-2 starter range 20-32 Amps complete all as specified and as directed. |
| 154 | Supply and fixing in replacement single phase preventor, type VSP-IIcomplete all as specified and as directed.(Note for ser item No 44 to 50:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 155 | Supply and fixing rotational moulded polyethylene water storage tank, cylindrical vertical with closed top, 500 ltrs capacity, tripple layered hoisted and fixed in position after taking down as existing at site (of any capacity) complete all as specified and as directed. Note: (i) For Pump Priming purpose in pump house.(ii) Old U/s PVC tank & lid cover as obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in plastic scrap weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 156 | Taking down cement plaster or cement lime plaster on PCC/Stone Surface/Brick surfaces including raking out joints hacking for keyscrubbing down with water etc complete all as specified and directed . |
| 157 | M&L Rendering 15 mm thick in CM (1:4) on fair faces of brickwork or concrete surfacesfinished even & smooth complete all as specified and directed . |
| 158 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoin jambs pillars etc complete all as specified and directed.(Note:- Old U/s brick work material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RVfor brick/brick bats in volume (CUM) shall be taken into account and attach with RAR/F Bill) |
| 159 | M&L Brick work with sub class \"B\" old size bricks bricks straight or curved on plan exceeding 6 m mean radious built in cement mortar 1:6 complete all as specified and directed. |
| 160 | Dismantling of cement concrete in ground floors and pavings n exc 15 cm thickness below or above ground level complete all as specified and directed. |
| 161 | M & L PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation for including fair finish even and fair to exposed surfaces without using extra cement complete all as specified and as directed |
| 162 | M&L Machine pressed precast concrete (rubberised/moulded paver block interlocking paverblocks) any shape and size confirming to IS 15658-2006 of 60 mm thick, M-35 Grade with grey cement and colour pigments laid, over 25 mm thick sand cushioning complete all as specified and as directed. (Note : Old U/s paver block material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in volume (CUM) shall be taken into account and attach with RAR/F Bill) |
| 163 | M&L Tank Cover/Valve Chamber Cover made out of mild steel plain sheet of any thickness as in cover for existing valve chamber along with provision of angle iron frame cut to length, bent to shape, welding and fabricate to requiredd shape/ size incl necessary fixing materials like hinges, nut/ bolts etc withtwo coat of synthetic enamel paint overa coat of red oxide primarand incl lifting handle andtaking out the old unsv valve chamber cover complete all as specified and directed.(Note : Old U/s cover material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 164 | M&L Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 1100 volts LT cables of different sizes from both ends , removal of fault , Reconnection and testing of cables after removal of fault complete all as specified and directed by Engr-in-charge. NOTE:(a) 1100 volt cables and joints shall be measured and paid for seperately under respective items of schedule (b) Retrieved old serviceable cable cover/ bricks will be laid in trenches for cable protection. If extra PCC cover / bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Exacavation and earth work will be measured and paid for separately under respective items of schedule. |
| 165 | Supply and fixing in replacement heat shrinkable jointkit suitable for XLPE cableinsulated screened PVC bedded armoured electric power cable heave duty1100 volts grade, with straded aluminium conductor, cross sectional area 25/35 Sqmm, 3.5 core after taking down/out faulty portion as exists compete all as specified and as directed.(Note : Old U/s joints material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 166 | M&L fabrication (welding work) of MS Header /any size upto 300 mm MS pipe at various pump house for arresting leakages on header complete all as specified and directed. |
| 167 | Supply and fixing DI MJ Collar fittings all as per IS: 9523 (2000) in replacement of following sizes complete all as specified and directed by Engr-in-Charge.(Note : Old U/s collar material obtained from demolition shall be taken on charge in demolition / salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill) |
| 168 | 80 mm dia |
| 169 | 100 mm dia |
| 170 | 150 mm dia |
| 171 | 200 mm dia |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy