Construction Of Shopping Complex At Padmanabhapuram At The Place Of Old Anganwadi Building At Padmanabhapuram-Ii Under Panchayat Samiti, Rangat (Iei).
BOQ
| Sl. No. | Item Description |
| 1 | Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches removing the roots and stacking of serviceable materialand disposal of unserviceable material. |
| 2 | Above 240 cm girth |
| 3 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. |
| 4 | All kinds of soil |
| 5 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 6 | All kinds of soil |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 8 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 9 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 10 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 11 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 12 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 13 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 14 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 15 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 16 | Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 17 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 18 | Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 19 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 21 | Foundations, footings, bases of columns, etc. for mass concrete |
| 22 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 23 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 24 | Suspended floors, roofs, landings, balconies and access platform |
| 25 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 26 | Stairs, (excluding landings) except spiral-staircases |
| 27 | Weather shade, Chajjas, corbels etc., including edges |
| 28 | Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like |
| 29 | Providing and laying Hollow cement concrete block walling 200mm thick consisting of hollow block of size 400x200x200mm of mix 1:3:6 (1cement:3 Pulverised sand:6 graded stone aggregates of 10mm nominal size) laid in cement martar 1:6 (1cement :6 pulverised sand). |
| 30 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 31 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. |
| 32 | 80x1.20 mm M.S. laths with 1.20 mm thick top cover |
| 33 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 34 | 40 mm thick with 20 mm nominal size stone aggregate |
| 35 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 36 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement |
| 37 | 18 mm thick |
| 38 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors. |
| 39 | 40 mm wide and 4 mm thick |
| 40 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 41 | 25 mm thick |
| 42 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete |
| 43 | 12 mm cement plaster of mix : |
| 44 | 1:4 (1 cement: 4 fine sand) |
| 45 | 6 mm cement plaster of mix : |
| 46 | 1:3 (1 cement : 3 fine sand) |
| 47 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 48 | Two or more coats on new work |
| 49 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: |
| 50 | New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 51 | Providing cement concrete surface drain with CC 1:3:6 (1:Cement, 3: Sand, 6: Graded Stone Aggregate 40 mm nominal size), including earthwork in excavation, 10cm thick bed concrete and 15cm thick side walling, finishing with 12mm thich cement plaster 1:4 and a floating coat of neat cement on top sides and insides and inside and disposal of surplus earth etc complete. |
| 52 | 15 x 15cm Surface drain. |
| 53 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 54 | ELECTRICAL WORKS |
| 55 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC Conduit, with piano type switch, suitable size PVC box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 56 | Group C |
| 57 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC Conduit, with 2 way piano type switch, suitable size PVC box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 58 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC Conduit, alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 59 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLSLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC Conduit as required. |
| 60 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 61 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 62 | Supplying and fixingSuitable PVC boxon surface or in recess, including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required.Make anchor/Polycab/Havells. |
| 63 | Supplying and fixing Suitable PVC box on surface or in recess, including providing and fixing 6 pin5/6 & 15/16amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.Make anchor/Polycab/Havells. |
| 64 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ PVC block including connection etc as required. |
| 65 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 66 | Supplying of LED 15W LED Bulb or Lamp, Make: Havells or Equivalent to ISI Standard. |
| 67 | Supplying of prewired LED tube light 20W LUMEN output 2000lm 6500K Product code PANASONIC PBTM02203 or equivalent to ISI standard.(Havells/Panasonic/Polycab) or Equivalent to ISI Standarad. |
| 68 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 69 | Supplying of A.C. Ceiling fan and regulator (1200mm sweep) with all accessories as required (Make: Bajaj/Usha/Orient/Crompton or equivalent to ISI standard). |
| 70 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 71 | Installation, testing and commissioning wired of Pre LED Tubelight, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 72 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). |
| 73 | 6 way, Double door |
| 74 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 75 | Single Pole |
| 76 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 77 | 40 Amps, 2 Pole Isolator |
| 78 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 79 | Providing and laying earth connection FRLSom earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe FRLSom earth electrode including connection with copper thimble excavation and re-filling as required. |
| 80 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 81 | Supplying and fixing rewirable porceline with fuse unit of 32 to 40 amps on energy meter board. |
| 82 | Supplying and Installation of 25W LED Street Light fittings of all sizes and shapes, excluding fabrication of metallic pole for road way light fitting upto 1.0 meters made out of 32 mm dia. G.I. pipe etc. including fixing on the wall, painting connections, complete with all accessories etc. as required. Make:- Crompton or Equivalent to ISI standard. |
| 83 | Supplying of ENDURA RUGBY energy saving new generation bulkhead luminaire with opal diffuser 10W LED 6000K similar to Havells Cat No. LHEOAOP7UZ6W010 or its equivalent to ISI standard. |
| 84 | Providing and fixing wooden board of size 10\"\" x 12\"\" for fixing of energy meter ectc. As required. |
AI Tender Summary
Tender Timeline
Jul 24, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedJul 30, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJul 30, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender