| 1 | Supplying, laying, commisioning and testing of 1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 7098) ISI marked in trenches / ducts / through GI pipes under roads of size 16 sqmm 2 core complete all as specifed and directed. Note;- The earth work, GI pipe shall be measured and paid sepretely under appropriate item of Sch A |
| 2 | All as per Item No 1here in before but Cable of size 16 Sqmm 4 Core complete all as specified and directed. |
| 3 | All as per Item No 1here in above but Cable of size 25 Sqmm 4 Core complete all as specified and directed. |
| 4 | All as per Item No 1here in above but Cable of size 50 Sqmm 3.5 Core complete all as specified and directed. |
| 5 | All as per Item No 1here in above but Cable of size 70 Sqmm 3.5 Core complete all as specified and directed. |
| 6 | All as per Item No 1here in above but Cable of size 150 Sqmm 3.5 Core complete all as specified and directed. |
| 7 | All as per Item No 1here in before but Cable of size 185 Sqmm 3.5 Core complete all as specified and directed. |
| 8 | Material and labour for design ,supply, fabrication, Installation, testing and commissoning Factory made LT panel at outdoor type totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 3.00 mm thick CRCA sheet, protection of enclousure IP-54 as per IS: 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size(minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed. |
| 9 | Busbar Chamber: -Electrically grade shrouded aluminium bus bar of capacity 600 Amps for each phase and 300 Amps for neutral andcurrent density 0.8A/Sqmm , including interconnection of all switch gears, fixed on DMC insulators and provision of extension.(Incoming)(a)MCCB 400 Amp, 415 Volts, 04 Pole 50Hz, 36 KA with adjustable thermal & magnetic release in built instantaneous protection, Ics = 100 % Icu(1 sec) - 01 Nos. (b) Ammeter 0 to 400 Amps digital type with built in selector switch, CTs ofratio 500/5A , 5va class 1.0 = 01 set.(c) Voltmeter 0 to 500 volts digital type with built in selector switch = 01 No(d) Phase Indication lamps (RYB), LED type - 01 No (set of three). (e)MCB SP 6 Amps 10 KA,for control protection RYB phase (set of 3)-01 set. (f ) AC three phase LT/CT multifunctional energy meter of accuracy class-0.5, 3x240 volts 50 Hz, with optical and RS 232 port, backlit LCD display, measures and display, trivector energyand load survey, TOD temper detection and lodging power on/off events, instantaneous parameter of rating-5 Amps, with display in absence of power complete -01 No |
| 10 | (Outgoing) Consist of separate compartment for each MCCB.-(a) MCCB 125 Amp, 415 Volts, 04 Pole 50Hz, 25KA with adjustable thermal magnetic release in built instantaneous protection, Ics = 100 % Icu(1 sec) - 02 Nos.(b) MCCB 100 Amp, 415 Volts, 04Pole 50Hz, 25/30 KA with adjustable thermal magnetic release in built instantaneous protection, Ics = 100 % Icu(1 sec) - 03 Nos. (c) MCCB 63 Amp, 415 Volts, 04 Pole 50Hz, 25/30 KA with adjustable thermal magnetic release in built instantaneous protection, Ics = 100 % Icu(1 sec) - 01 Nos.(d) MCB TPN 40Amp - 03 Nos (e) Astronomical timer switch- 01. |
| 11 | Material and labour for design ,supply, fabrication, Installation, testing and commissoning Factory made LT panel at outdoor type totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 3.00 mm thick CRCA sheet, protection of enclousure IP-54 as per IS: 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size(minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed. |
| 12 | Busbar Chamber: -Electrically grade shrouded aluminium bus bar of capacity 200 Amps for each phase and 100 Amps for neutral andcurrent density 0.8A/Sqmm , including interconnection of all switch gears, fixed on DMC insulators and provision of extension.(Incoming)(a)MCCB 100 Amp, 415 Volts, 04 Pole 50Hz, 30 KA with adjustable thermal & magnetic release in built instantaneous protection, Ics = 100 % Icu(1 sec) - 01 Nos. (b) Ammeter 0 to 100 Amps digital type with built in selector switch, CTs ofratio 100/5A , 5va class 1.0 = 01 set.(c) Voltmeter 0 to 500 volts digital type with built in selector switch = 01 No(d) Phase Indication lamps (RYB), LED type - 01 No (set of three). (e)MCB SP 6 Amps 10 KA,for control protection RYB phase (set of 3)-01 set. |
| 13 | (Outgoing) Consist of separate compartment for each MCCB.-(a) MCCB 63 Amp, 415 Volts, 04 Pole 50Hz, 30 KA with adjustable thermal magnetic release in built instantaneous protection, Ics = 100 % Icu(1 sec) - 01 Nos. (b) MCB TPN 40Amp - 03 Nos |
| 14 | Material and labour for design ,supply, fabrication, Installation, testing and commissoning Factory made LT panel at outdoor type totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 3.00 mm thick CRCA sheet, protection of enclousure IP-54 as per IS: 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size(minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed. |
| 15 | Busbar Chamber: -Electrically grade shrouded aluminium bus bar of capacity 200 Amps for each phase and 100 Amps for neutral andcurrent density 0.8A/Sqmm , including interconnection of all switch gears, fixed on DMC insulators and provision of extension.(Incoming)(a)MCCB 100 Amp, 415 Volts, 04 Pole 50Hz, 30 KA with adjustable thermal & magnetic release in built instantaneous protection, Ics = 100 % Icu(1 sec) - 01 Nos. (b) Ammeter 0 to 100 Amps digital type with built in selector switch, CTs ofratio 100/5A , 5va class 1.0 = 01 set.(c) Voltmeter 0 to 500 volts digital type with built in selector switch = 01 No(d) Phase Indication lamps (RYB), LED type - 01 No (set of three). (e)MCB SP 6 Amps 10 KA,for control protection RYB phase (set of 3)-01 set. |
| 16 | (Outgoing) Consist of separate compartment for each MCCB.-(a) MCCB 40 Amp, 415 Volts, 04 Pole 50Hz, 16 KA with adjustable thermal magnetic release in built instantaneous protection, Ics = 100 % Icu(1 sec) - 01 Nos. (b) MCB TPN 40Amp - 03 Nos (c) Contactor 3 pole 40 AMp- 01 No (d) Astronomical timer switch- 01. |
| 17 | Material and labour for design ,supply, fabrication, Installation, testing and commissoning Factory made LT panel at outdoor type totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 3.00 mm thick CRCA sheet, protection of enclousure IP-54 as per IS: 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size(minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed |
| 18 | Busbar Chamber: -Electrically grade shrouded aluminium bus bar of capacity 200 Amps for each phase and 100 Amps for neutral andcurrent density 0.8A/Sqmm , including interconnection of all switch gears, fixed on DMC insulators and provision of extension.(Incoming) (a)MCCB 63 Amp, 415 Volts, 04 Pole 50Hz, 30 KA with adjustable thermal & magnetic release in built instantaneous protection, Ics = 100 % Icu(1 sec) - 01 Nos. (b) Ammeter 0 to 100 Amps digital type with built in selector switch, CTs ofratio 100/5A , 5va class 1.0 = 01 set.(c) Voltmeter 0 to 500 volts digital type with built in selector switch = 01 No(d) Phase Indication lamps (RYB), LED type - 01 No (set of three). (e)MCB SP 6 Amps 10 KA,for control protection RYB phase (set of 3)-01 set. (f) Astronomical timer switch- 01. |
| 19 | (Outgoing) Consist of separate compartment for each MCCB.-(a) MCB TPN 40Amp - 04 Nos |
| 20 | Material and labour for design ,supply, fabrication, Installation, testing and commissoning Factory made LT panel at outdoor type totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 3.00 mm thick CRCA sheet, protection of enclousure IP-54 as per IS: 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size(minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed. |
| 21 | Busbar Chamber: -Electrically grade shrouded aluminium bus bar of capacity 200 Amps for each phase and 100 Amps for neutral andcurrent density 0.8A/Sqmm , including interconnection of all switch gears, fixed on DMC insulators and provision of extension.(Incoming)(a)MCCB 100 Amp, 415 Volts, 04 Pole 50Hz, 30 KA with adjustable thermal & magnetic release in built instantaneous protection, Ics = 100 % Icu(1 sec) - 01 Nos. (b) Ammeter 0 to 100 Amps digital type with built in selector switch, CTs ofratio 100/5A , 5va class 1.0 = 01 set.(c) Voltmeter 0 to 500 volts digital type with built in selector switch = 01 No(d) Phase Indication lamps (RYB), LED type - 01 No (set of three). (e)MCB SP 6 Amps 10 KA,for control protection RYB phase (set of 3)-01 set. |
| 22 | (Outgoing) Consist of separate compartment for each MCCB.-(a) MCCB 63 Amp, 415 Volts, 04 Pole 50Hz, 16 KA with adjustable thermal magnetic release in built instantaneous protection, Ics = 100 % Icu(1 sec) - 01 Nos. (b)MCCB 40 Amp, 415 Volts, 04 Pole 50Hz, 16 KA with adjustable thermal magnetic release in built instantaneous protection, Ics = 100 % Icu(1 sec) - 01 Nos(c) MCB TPN 40Amp - 01 Nos (c) Contactor 3 pole 40 AMp- 01 No (d) Astronomical timer switch- 01. |
| 23 | Material and labour for design ,supply, fabrication, Installation, testing and commissoning Factory made LT panel at outdoor type totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 3.00 mm thick CRCA sheet, protection of enclousure IP-54 as per IS: 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size(minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed. |
| 24 | Busbar Chamber: -Electrically grade shrouded aluminium bus bar of capacity 200 Amps for each phase and 100 Amps for neutral andcurrent density 0.8A/Sqmm , including interconnection of all switch gears, fixed on DMC insulators and provision of extension.(Incoming)(a)MCCB 125 Amp, 415 Volts, 04 Pole 50Hz, 30 KA with adjustable thermal & magnetic release in built instantaneous protection, Ics = 100 % Icu(1 sec) - 01 Nos. (b) Ammeter 0 to 200 Amps digital type with built in selector switch, CTs ofratio 200/5A , 5va class 1.0 = 01 set.(c) Voltmeter 0 to 500 volts digital type with built in selector switch = 01 No(d) Phase Indication lamps (RYB), LED type - 01 No (set of three). (e)MCB SP 6 Amps 10 KA,for control protection RYB phase (set of 3)-01 set. |
| 25 | (Outgoing) Consist of separate compartment for each MCCB.-(a) MCB TPN 40Amp - 06 Nos(b) Astronomical timer switch- 01. |
| 26 | Material and labour for design ,supply, fabrication, Installation, testing and commissoning Factory made LT panel at outdoor type totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 3.00 mm thick CRCA sheet, protection of enclousure IP-54 as per IS: 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size(minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed. |
| 27 | Busbar Chamber: -Electrically grade shrouded aluminium bus bar of capacity 200 Amps for each phase and 100 Amps for neutral andcurrent density 0.8A/Sqmm , including interconnection of all switch gears, fixed on DMC insulators and provision of extension.(Incoming) (a)MCCB 125 Amp, 415 Volts, 04 Pole 50Hz, 30 KA with adjustable thermal & magnetic release in built instantaneous protection, Ics = 100 % Icu(1 sec) - 01 Nos. (b) Ammeter 0 to 200 Amps digital type with built in selector switch, CTs ofratio 200/5A , 5va class 1.0 = 01 set.(c) Voltmeter 0 to 500 volts digital type with built in selector switch = 01 No(d) Phase Indication lamps (RYB), LED type - 01 No (set of three). (e)MCB SP 6 Amps 10 KA,for control protection RYB phase (set of 3)-01 set. |
| 28 | (Outgoing) Consist of separate compartment for each MCCB.-(a) MCCB 63 Amp, 415 Volts, 04 Pole 50Hz, 16 KA with adjustable thermal magnetic release in built instantaneous protection, Ics = 100 % Icu(1 sec) - 01 Nos. (b)MCCB 40 Amp, 415 Volts, 04 Pole 50Hz, 16 KA with adjustable thermal magnetic release in built instantaneous protection, Ics = 100 % Icu(1 sec) - 01 Nos(c) MCB TPN 40Amp - 02 Nos |
| 29 | Material and labour for design ,supply, fabrication, Installation, testing and commissoning Factory made LT panel at outdoor type totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 3.00 mm thick CRCA sheet, protection of enclousure IP-54 as per IS: 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size(minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed. |
| 30 | Busbar Chamber: -Electrically grade shrouded aluminium bus bar of capacity 200 Amps for each phase and 100 Amps for neutral andcurrent density 0.8A/Sqmm , including interconnection of all switch gears, fixed on DMC insulators and provision of extension.(Incoming)(a)MCCB 63Amp, 415 Volts, 04 Pole 50Hz, 30KA with adjustable thermal & magnetic release in built instantaneous protection, Ics = 100 % Icu(1 sec) - 01 Nos. (b) Ammeter 0 to 100 Amps digital type with built in selector switch, CTs ofratio 100/5A , 5va class 1.0 = 01 set.(c) Voltmeter 0 to 500 volts digital type with built in selector switch = 01 No(d) Phase Indication lamps (RYB), LED type - 01 No (set of three). (e)MCB SP 6 Amps 10 KA,for control protection RYB phase (set of 3)-01 set. |
| 31 | (Outgoing) Consist of separate compartment for each MCCB.-(a) MCB TPN 40Amp - 03 Nos |
| 32 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground levelat any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 32x6 mm GI Strip,check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI Strip upto 7.5 mtrs long with 40 mm dia Medium grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip toDB, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover.(ii) Cost of additional GI Wire more than 7.5 mtrs will be measured and paid seperately under relevant items. |
| 33 | Excavation in trenches in soft/disintegrated soil not exc 1.5 m wide and not exceeding1.5m in depth forlaying UG cable/foundation etc complete all as specified and directed. |
| 34 | Returning filling in soft/disintegrated soil including spreading levelling watering and well ramming in layers n.exc 25cm each layer complete all as specified and directed. |
| 35 | Removal of excavated surplus soft/disintegrated soil to a distance not exc 50 mtrand depositing where directedat a level not exc 1.5 mtrabove the starting point complete all as specified and directed. |
| 36 | M&L for sand cushioning for under ground cable with layer of fine river dry sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed. Note:- Punned (consolidated ) thicness of sand will be measured and paid sepetarely under relevent item of Sch. |
| 37 | M&L for cable protection bricks common burnt clay sub class B designation 75 for protection of UG Cable laid in trenches complete all as specified and directed. |
| 38 | S&F galvanised steel water tubing (GI pipe), light grade with all fittings (ISI Marked) and fixed to wall, floor and ceiling or laid in trenches of following bore complete all as specified and as directed :- |
| 39 | 40mm bore |
| 40 | 50mm bore |
| 41 | 80mm bore |
| 42 | 100mm bore |