Bids Are Invited For RC for Call Basis Repairs and misc works of Split AC in various BAs of EC Mumbai - Attending complaint and wet servicing of AC unit upto 50 Kms , Attending complaint and wet servicing of AC unit upto 51 to 100 Kms , Attending complaint and wet servicing of AC unit above 101 Kms , Replacement of Starting Capacitor 80 to 100 mfd of AC unit , Replacement of Running capacitor 36 to 50 mfd of AC unit , Replacement of Capacitor for Condenser Fan 4 to 6 mfd of AC unit , Replacement of Sensor for Split AC unit , Replacement of Contactor relay for Split AC outdoor unit , Replacement of Starting Relay of AC unit , Replacement of Thermostat of AC unit , Replacement of Selector Switch of AC unit , Replacement of Blade for condensor of Window or Split AC unit , Replacement of Blower Assembly for Split AC unit without motor , Replacement of PCB for conventional Split AC indoor unit of 1.5 TR , Replacement of PCB for outdoor unit of Invertor type Split AC , Replacement of PCB for indoor unit of Invertor type Split AC , Replacement of 1.5TR or 2TR Split AC Remote , Replacement of Fan motor for Condenser unit of conventional 1.5 or 2 TR of AC , Replacement of Blower Motor for Indoor unit of 1.5TR or 2 TR of Split AC , Replacement of 20mm dia flexible PVC pipe for drain water connection of AC , Charging of R22 or R32 or R134 or R410 refrigerant gas upto the optimum working pressure suitable for 1.5 or 2TR AC alongwith attending leakage , Replacement of Cond coil manufactured with cu tube and AL fins with antirust coating and blue fin hydrophilic coating for SAC incl. credit of old coil , Dismantling of window AC unit alongwith casing MS supporting frame , Dismantling of Split or High Sensible AC incl. ID and OD unit aw all acc. pump down of gas and keeping all dismantled material at safe location , Transportation of dismantled 2 No. AC units Upto 20 KM with all accessories incl. hiring of vehicle, manpower etc, Transportation of dismantled 3No. to 5 No. AC units Upto 20 KM with all accessories incl. hiring of vehicle, manpower etc , Transportation of dismantled 2 No. AC units From 21 KM to 50 KM with all accessories incl. hiring of vehicle, manpower etc , Transportation of dismantled 3No. to 5 No. AC units From 21 KM to 50 KM with all accessories incl. hiring of vehicle, manpower etc , Transportation of dismantled 2 No. AC units From 51 KM to 100 KM with all accessories incl. hiring of vehicle, manpower etc , Transportation of dismantled 3No. to 5 No. AC units From 51 KM to 100 KM with all accessories incl. hiring of vehicle, manpower etc , Transportation of dismantled 3No. to 5 No. AC units From 100 KM Upto 200 KM with all accessories incl. hiring of vehicle, manpower etc , ITC of 1.5 or 2TR Window AC unit with properly finshing and minor civil work , ITC of wall mounting type 1.5 or 2TR Split AC unit with properly finishing and minor civil work , ITC of 2x1.5 TR High Sensible AC unit with properly finishing and minor civil work , S and F of 1 by 4 inch Copper refrigeration pipe , S and F of 3 by 8 inch Copper refrigeration pipe , S and F of 1 by 2 inch Copper refrigeration pipe , S and F of 5 by 8 inch Copper refrigeration pipe , P and W of expanded polyethylene foam tube insulation for 1 by 4 inch Copper refrigeration pipe , P and W of expanded polyethylene foam tube insulation for 3 by 8 inch Copper refrigeration pipe , P and W of expanded polyethylene foam tube insulation for 1 by 2 inch Copper refrigeration pipe , P and W of expanded polyethylene foam tube insulation for 5 by 8 inch Copper refrigeration pipe , S and F of prefabricated powder coated heavy duty iron stand having projection arm minimum 600 MM , S and fabrication of M.S. frame made out of various M.S. Sections incl. hardwares finishing, painting, minor civil work etc , P and F of 12mm thick prelaminated particle board with decorative lamination on both side flat pressed 3 layer or graded wood particle board , S and L of 4 X 1.5 Sq mm copper conductor unarmoured cable of 1.1 KV grade ISI mark , S and L of 3 X 2.5 Sq mm copper conductor unarmoured cable of 1.1 KV grade ISI mark , S and F of 20 mm Dia heavy gauge rigid UPVC pipe of ISI mark , S and F of 25 mm Dia heavy gauge rigid UPVC pipe of ISI mark , S and L of 3 X 2.5 Sq mm copper conductor armoured cable of 1.1 KV grade ISI mark , S and M end termination with brass compression gland for 3 X 2.5 Sq mm size of PVC insulated PVC sheathed or XLPE CU condr armd cable , S and F of 2 way SPN MCB DB , S and F of 5A to 32A 10KA C curve SP MCB , S and F of 5A to 32A 10KA C curve SPN MCB , S and F microprocessor based energy saver unit for controlling the operation of 2 A.C. unit having safety protection, disply, auto, manual mode , Repairing of faulty AC controller of AC unit , Sand F of electronic AC voltage stabilizer suitable for operation on 130Volt to 290 Volt for 1.5TR AC unit , Installation of SPN or TPN MCB DB , Fixing of SP or SPN or DP or TP or TPN or FP MCB , Fixing of outdoor condensor Stand , Fixing of both size of refregerent piping but Without heatlone tube , Laying of 2 or 3 or 4 core copper conductor armoured or unrmoured cable up to size 4 sq mm. , Fixing of Cyclic timer , Fixing of 20mm or 25mm dia drain water PVC pipe. Total Quantity : 4641