Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #44346138

Tender For Repair/ Maintenance Of Street Light And Garden Light, High Mast Lights, Street Light Panels, Street Light Controller Etc At Technical And Residential Area Of Deal Under Ge (I) Rnd Dehradun

Issued by Statutory Bodies & Commissions/Committees · dehradun, Uttarakhand
Tender Value
8 Lakhs
Estimated cost
Bid Submission
13 Sep 2024
0 days left
EMD
16000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
dehradun → Uttarakhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Repair/ Maintenance Of Street Light And Garden Light, High Mast Lights, Street Light Panels, Street Light Controller Etc At Technical And Residential Area Of Deal Under Ge (I) Rnd Dehradun

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 30-Aug-2024 Due Date Extended for tenders closing on 12-08-2024. Admin Corrigendum Date Extend 06-Sep-2024
2 06-Sep-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-Sep-2024

BOQ

NAME OF WORK : REPAIR/ MAINENANCE OF STREET LIGHT AND GARDEN LIGHT, HIGH MAST LIGHTS, STREET LIGHT PANELS, STREET LIGHT CONTROLLER ETC AT TECHNICAL AND RESIDENTIAL AREA OFDEALUNDER GE (I) R&D DEHRADUN
Sl. No. Item Description
1Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient forlaying cables/pipes etc. including removing cable protection covers/ bricks complete all as specified and directed. Notes : (i) Excavation shall be made carefully in order to avoid damage of existing cables and brick protection.(ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations
2M&L for Returning, filling in, including spreading leveling, watering and well ramming the excavated soil in layers not exceeding 25 cm thick complete all as specified and directed.
3M&L for Removal of surplus excavated soil to a distance not exceeding 50 Mtr distance and depositing as directedat a level not exceeding 1.5 mtr above starting point complete all as specified and directed.
4Material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches/ducts for cable protection complete all as specified and directed.(NOTE : Thickness after punning shall be measured for payment)
5M&L for Un-reinforced precast concrete cable cover class LV type I, flat, size 250mm x 150mm x 40mm as proteciton to under ground cable laid dry flat adjoining each other complete all as specified and directed
6Fixing / laying only old retrieved PCC Cable Cover of any description as obtained from dismantling of the cable complete all as specified and directed.
7Disconnecting and taking out old unserviceable GI pipe and Supplying, laying & jointing GI water tubing, 50 mm bore, light grade as in sleeving etc laid in trenches / pole post etc, cutting and making necessaries arangement by means of wedling and jointing suitable for post of larntent/ street light fitting including PCC work complete all as specified and directed. (Note : PCC work shall be measured and paid seperatly under Sch \"A\" relevent item)
8Disconnecting and taking out old existing unserviceable/ non- functional LT Cable and Supplying, laying, jointing and testing cable XLPE insulated IS 7098 (Part-I)-1988 marked, screened, PVC sheathed, armoured electric power cable (heavy duty) with aluminum conductor for working voltage upto and including 1100 Volts, cross sectional area of under mentioned size of cables laid in trenches/fixed on pole/wall / passed through pipe complete all as specified and directed. (NOTE: Earth work, sand cushioning, pipe, clamps for holding cables and brick protection shall be measured and paid separately )
910 Sqmm 2 core
1016 Sqmm 2 core
1125 Sqmm4 core
1235 Sqmm 3.5 core
13Labour only for checking the serviceability of the different spares / components / parts of security light fittings/post top lantern light fittings (LED,HPSV, Metal Halide, flood lightfittings etc, any wattage/capacity) of any description and fixed in any position, replacement of un-serviceable/damaged/ broken part(s) either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and its testing on installation complete all as specified and directed here in after in notesNOTES FOR SCH `A’ ITEM NO 13:-(i) Replacement of parts i.e Drivers,SPD, LED board,lamps, choke, Igniter, Condenser, Holder, covers etc for Street/Flood light fittings any wattage & capacity, if any required at site, shall be measured and paid for separately under appropriate item of Schedule `A\" as ‘supply only. (ii) Necessary T&P i.e. ladder, tools etc required for checking and making the light fittings in serviceable conditions, its fixing in position and testing shall be arranged by the contractor at his own cost for checking and fixing of street light fittings/security light fittings of any description on poles / on walls / on pillars etc i.e. in any position at site.(iii)Required screws, insulating tapes, internal wiring wire and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item. (iv)Contractor shall be paid only one time the labour charges quoted above in Schedule `A\" items for a particular fitting repaired irrespective of the number of times labour and resources arranged by him to check the serviceability of the fittings and replacement of unserviceable / defective parts in order to maintain the fittings in serviceable/working condition. (v) Contractor’s quoted rates for Schedule `A\" item No 13 is deemed to include for inspection/checking the serviceability of the fittings in position or by taking down as per site requirement, removing the damaged unserviceable / broken parts, fixing the new parts as required, fixing the fittings in same position or the other, connecting the fittings with electric source and testing of fittings as directed.
14Supply onlythe following parts for LED fittings complete all as specified and directed. NOTES:(i) Fixing element of these items is deemed to be included in the rates quoted by the contractor for Sch `A\" item No 13(ii) Spare parts/items shall be of make Crompton Greaves/Philips/Bajaj/Havells & suitable for the existing fittings.(iii) The above items shall be operated with prior written approval of GE and when required spares are not available with the deptt to issue to contractor under Sch ‘B’ “Free for fixing” and Contractor shall have no claim on account of non execution of above items.
15Driver Suitable for 45/48Watt LED fittings.Make:C&S/Havells/Bajaj/Crompton
16Driver Suitable for 60Watt LED fittings, Make:C&S/Havells/Bajaj/Crompton
17Driver Suitable for 90Watt LED fittings,Make:C&S/Havells/Bajaj/Crompton
18Driver Suitable for 100/120/150Watt LED fittings. Make:C&S/Havells/Bajaj/Crompton
19Surge Protection Device (SPD). Make:C&S/Havells/Bajaj/Crompton
20M&L for making holes in electric/street light poles of any height or in any shape, by means of drill machine and drawing of drawing of 1.5sqmm x3 core cable through the hole from junction box to the hole on the top of pole near the street light fitting complete with all electric connections complete all as specified and directed. (Rates of the cable deemed to be included)
21Taking down existingunserviceablebracket complete and S&F 40 mm dia GIlightgrade pipe bracket 1.50 m long bent to shape by cutting & weldingas required & directed and fixed to pole withtwo Nos of FI clamps 40x5 mm to be tightened with bolts, nut and washers and including painted withtwo coat of aluminium paint over a coat of red oxide primer complete all as specified and directed.Make of pipe TATA / Jindal / Swastik / Prakash / BSTor any other ISI marked make approved by GE.
22Supply and fixing in replacement of UNSV LED bollard light 10 W, IP 65 rated,efficient light distribution complete withaccessories to be fixed in Groundincludingconnecting the fitting to control switch at the bottom of the Junction boxwith using 2.5 Sqmm two single core PVC insulated and unsheathed copper conductor cable complete,all as specified and directed Make : Crompton/ Havells/ C&S/Bajaj(Note :PCC work shall be measured and paid seperatly under Sch \"A\" relevent item and rate of cable deemed to be included )
23Supply and fixing in replacement of UNSV 20W LED Post top lantern complete accessories to be fixed on pole/wall includingconnecting the fitting to control switch at the bottom of the pole with using 2.5 Sqmm two single core PVC insulated and unsheathed copper conductor cable complete,all as directed and directed.Make : Cromptonof /Havells/ C&S/Bajaj/Shakti. (Note :PCC work shall be measured and paid seperatly under Sch \"A\" relevent item and rate of cable deemed to be included )
24Supply and fixing in replacement of UNSV 40W LED Post top lantern complete accessories to be fixed on pole/wall includingconnecting the fitting to control switch at the bottom of the pole with using 2.5 Sqmm two single core PVC insulated and unsheathed copper conductor cable complete,all as directed and directed. Make : Crompton/ Havells/ C&S/Bajaj/ Shakti.(Note :PCC work shall be measured and paid seperatly under Sch \"A\" relevent item and rate of cable deemed to be included )
25Taking down old unserviceablejunction boxes from the pole with disconnectiong all connections, Supplying and fixing in position Junction box made of SMC/FRP sheet ready madeof size 300 mm x 200 x 105 mm having 100 A Capacity RYB and neutralaluminium bus bar of 3 mm thickduly fitted on suitable insulator . The gasket should be internally embedded, and made of Polyeutherene.Box shall be suitable for up to 35Sqmm cables including one no. MCB SP 230 volts6 amps and connecting the bus bars to cables withusing suitable GI nut, bolts and washers and aluminum lugs etc fixed on pole using 30x5mm FI clamps,nuts,bolts & washers complete all as specified and directed.
26All as per item No 25 above butJunction Boxsize 205 X 255 X112 MM (LXBXH) andshall be suitable for 16/25Sqmm cables .
27Material & labourof PCC 1:3:6 type C-2 using 20 mm graded stone aggregate (4 stay). in mass concrete and filling completefor foundation/hard standing coping , complete all as specified and directed.
28M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling of poles and mass concrete etc complete all as specified and directed.
29M & L for cutting chases in hard standing road/path/drain etc for passing cables/pipes etc. size of and removing the excavated materials and disposal at 50 metre distance and making good the cutting after the pipe and cables are laid with PCC 1:3:6 type C-1 using 20mm graded stone aggregates complete all as specified and directed.
30Supplying,erecting and fixing in replacement of UNSV steel tubular swaged pole (410 SP – 31), 9 mtr long,in true vertical position complete conforming to IS : 2713 (Part-I & III) 1980 with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole with and including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole finished with one coat of red oxide primer complete, all as specified and directed. (Note : Excavation and PCC work shall be measured and paid seperatly under Sch \"A\" relevent item)
31Supply, fixing & testing in replacement of UNSV15W LED street light with polly corbonate cover with high inpact resistance, 15 W-1500 lumens with efficacy of 100 lumans /wall at system level, ingress protection of IP65 PF-0.9 & with input resistanct i.e.IK 09 surge protectin upto 4KV,compiled withIS 10322 CCT is greater than 5000K,complete with all accessories duly prewired, supply and fixing the bracket of 40 mm dia 60 cm long GI pipe light grade bent to shap and including MS FI clamp of 20X3 mm nut and bolts and connected with flexible cable 3 core copper conductor 0.5 Sqmm upto ceiling rose complete mounting on existing MS frame bracket including connecting the fitting complete, all as specified and directed.Make-Crompton / Havells/C& S/Bajaj/ Shakti. (Note :- GI pipe bracket and clamp shall be measured and paid seperatly under Sch \"A\" relevent item)
32Supply, fixing & testing in replacement of UNSV45W LED street light IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewiredand suitable fixing arragement for mounting on existing MS framebracketincluding connecting the fittingcomplete all as specified and directed.Make-Crompton / Havells/C& S/Bajaj / Shakti. (Note :- GI pipe bracket and clamp shall be measured and paid seperatly under Sch \"A\" relevent item)
33Supply, fixing & testing in replacement of UNSV60W LED street light IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewiredand suitable fixing arragement for mounting on existing MS framebracketincluding connecting the fittingcomplete all as specified and directed.Make- Crompton / Havells/C& S/Bajaj). (Note :- GI pipe bracket and clamp shall be measured and paid seperatly under Sch \"A\" relevent item)
34Supply, fixing & testing in replacement of UNSV 70W LED street light IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewiredand suitable fixing arragement for mounting on existing MS framebracketincluding connecting the fittingcomplete all as specified and directed.Make- Crompton/Havells/C& S/Bajaj/ Shakti. (Note :- GI pipe bracket and clamp shall be measured and paid seperatly under Sch \"A\" relevent item)
35Supply, fixing & testing in replacement of UNSV90W LED street light IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewiredand suitable fixing arragement for mounting on existing MS framebracketincluding connecting the fittingcomplete all as specified and directed.Make- Crompton/Havells/C& S/Bajaj/ Shakti. (Note :- GI pipe bracket and clamp shall be measured and paid seperatly under Sch \"A\" relevent item)
36Supply, fixing & testing in replacement of UNSV 120W LED Flood light IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewiredand suitable fixing arragement for mounting on existing 16 mtrs High Mast/11 mtrs pole /9 mtrs poleor Bldg MS frame/bracketincluding connecting the fittingcomplete all as specified and directed. Make- Crompton/Havells/C& S/Bajaj/Shakti (Note : GI pipe bracket shall be measured and paid seperatly under Sch \"A\" relevent item)
37Material and labour for cleaning and preparation of all existing steel surfaces of straight Electric/ steel tubular poles 9 mtrs long for painting including mild steel cross arms, clamps and street light brackets,protection pipe, MS boxes etc and applying Two coat of aluminium paint all round the exposed steel surfaces of existing steel tubular poles of any description and in any position above the height of 1.50 mtr from the plinth of the pole and applying one coat of synthetic enameled paint of different colours in strips of 150mm width upto the height 1.5 mtr from the plinth of polecomplete all as specified and directed.
38Material and labour for cleaning and preparation of all existing steel surfaces of straight Electric/ steel tubular poles 11 mtrs long for painting including mild steel cross arms, clamps and street light brackets,protection pipe, MS boxes etc and applying Two coat of aluminium paint all round the exposed steel surfaces of existing steel tubular poles of any description and in any position above the height of 1.50 mtr from the plinth of the pole and applying one coat of synthetic enameled paint of different colours in strips of 150mm width upto the height 1.5 mtr from the plinth of polecomplete all as specified and directed.
39M & L for re-writing letters or figures (Black, roman, Indian)for electric/ street light pole Nos on existing poles with stencilout with black colour including fixing red colour radium of 80 mm hight arround the radius of pole complete all as specified and directed.

AI Tender Summary

OUR REF NO 44346138
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 8 Lakhs
LAST DATE 13-09-2024
Authority
Authority Name Military Engineer Services
Work Description Tender For Repair/ Maintenance Of Street Light And Garden Light, High Mast Lights, Street Light Panels, Street Light Controller Etc At Technical And Residential Area Of Deal Under Ge (I) Rnd Dehradun
Basic Detail
Tender No GE(I)RND/9381/E8/24-25
Bidding Type Tender
Location
City dehradun
State Uttarakhand
Key Dates
Publish Date 06 Sep 2024
Submission Date 13 Sep 2024
Open Date 16 Sep 2024
Finance
Tender Value 8 Lakhs
Tender Fee 500
EMD 16000
Exemption Available
Document List
47308423-d16d-4bd6-a41f-46c0b42e96ad.html
BOQ_746095.xls
Genpage9381.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 06, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 06, 2024
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 13, 2024
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 13, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 16, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

47308423-d16d-4bd6-a41f-46c0b42e96ad.html

xls

BOQ_746095.xls

pdf

Genpage9381.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders