| 1 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil complete all as specified. complete all as specified and directed. |
| 2 | Removing excavated material n exc. 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and as directed. |
| 3 | M & L for hard core of broken stone of gauge not exceeding 63mm (i.e.40mm) deposited spread and levelled in layer not exceeding 15cm thick watered and well rammed to true surfaces complete all as specified and directed. |
| 4 | M&L for 50mm thick PCC 1:4:8 type D-1 (using 20mm graded crushed stone aggregate) as in sub base, surface finished even and fair, complete all as specified and directed.all as specified and directed |
| 5 | M&L Machine pressed, precast conctete interlocking paver block, any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and pigment over and including 50mm thick crushed stone sand cushioning complete all as specified and as directed. |
| 6 | M& L for PCC 1:2:4 type B-1 (using 20 mm graded agg) in kerbs , rounded or chamfered on edges including necessary form work complete all as specified and directed. |
| 7 | M&L forbrick work with sub class \"B\" bricks (old size) straight or curved on plan exceeding 6 m mean radius, built in CM1:6 complete all as specified and directed. |
| 8 | M&L for rendering 15 mm thick ( External surface) fair faces of brick work or concrete surfaces on walls in CM 1:4. finishing even and smooth without using extracement complete all as specified and directed. |
| 9 | M&L for cutting holes into or through brick walls built in cement mortar or cement lime mortar of superficial area n.exc 150 sq.cm complete all as specified and directed. |
| 10 | S & F 110mm bore PVC(SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 11 | S & F 110mm bore PVC(SWR) bends complete all as specified and directed. |
| 12 | M&L for 20 mm thick Zed- Black or approved shed Granite (of any type ) work (table rounded and polished) in steps, jambs, pillars, window-cills, cooking platforms and like over and including 15mm thick screed bed/backing in cement mortar 1:4 and jointed in cement slurry and pointing in white cement 1:2 using marble dust with admixer of pigment to match with shade of granite complete all as specified and directed |
| 13 | Supply, install, testing and commissioning of 12mm thick toughened glass door for double opening of size 3.90m x3.10m with and including automated door opener system using, Auto door set 1 controller, 1 Motor having 24V and 60W brushless DC motor, 2 PIR sensors 15m range with input voltage 12-36 voltAC/DC with relay, NO and NC type with delay features, 2 Remote control, 7 Meter Belt, 1 Tension PulleyDevice, 1 Power Switch, 2 Stopper, 4.2 Meter Cover, input voltage AC 220V, 60 Hz, door opening speed 15-45Cm/Sec, door closing speed 10-43 Cm/Sec.Glass door witll be fixed using SS bracket for wall and floor. All as per Model No GT-2011 of M/s Globetech or equivalent as approved by GE. |
| 14 | M&L for 12 mm thick toughened glass as in partitions fixed with suitabe size stainless steel cleats to wall, ceiling and floor with stainless steel fastners of suitabe size complete all as specified as directed. |
| 15 | Supply and fixing three phase floor electric sliding gate motor , 220 Volts, 50 Hz, AC having rack and pinion arrangement for suitable speed conversion of motor speed 1500 rpmto sliding gate closing speed 16 cm/sec, having two poles , IP-54, ISI marked , operating temperature -20 to +50 degree centigrade and of capacity upto 1.5 KW including making of PCC plinth for its base and connecting the cables to motor from the nearest supply point and making connection such that it can be operated through a point given in guard roomcomplete all as specified and directed by engineer-in-charge. |
| 16 | Supplying, laying and testing PVC sheathed cable galvanised steel strip or wire armoured, electric control cables (Heavey duty) with stranded Aluminium conductor of size 10 sqmm, 4 core 1100 Volts grade. |
| 17 | supply and fixing MCCB FP 63 Amp , rapturing capacity 35 KA , 415 Volts in existing panel complete all as specified and directed. |
| 18 | Material and labour for GI pipe 40 mm dia\"light grade \" complete with all fittings laid in trenches,road/culvert crossing,on wall, floors,on roof,on pole, for cable protection and including removing old unserviceable item complete all as specified and directed. Make:- Jindal/Tata/BST |
| 19 | Supply and fix MCCB FP 32 Amp with box for connection of Gate motor in Guard room and provide connection to motor complete all as specified and directed by engineer incharge. |
| 20 | Excavation in trenches , not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft loose soil complete all asspecified and directed. |
| 21 | Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed |
| 22 | Removing excavated soil not exc50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed |