Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 30-08-2024 | Due Date Extended for tenders closing on 10-08-2024. | Admin Corrigendum Date Extend | 06-09-2024 |
| Sl. No. | Item Description |
| 1 | Material and labour for repair, maint and making the continuity of supply after rectifying the defects of the electrical items such as tube light fittings,switches, replacement of fuse wires, distribution boards, MCB (light/power), lamp holders (bracket/ pandents/ batten), bell/buzzer, push button, ceiling rose, capacitors and other similar electrical items/fittings etc. including provisioning of small pieces of electrical wire of size 1 sqmm to 10 sqmm single core and length not exceeding 0.50 mtrs complete all as specified and directed by Engineer-in-Charge (Note :- (i) any accessories found unserviceable that shall be replaced under respective items of this Sch. Note : If complaint not completed within thesame day then Rs 100/- of penalty will be recovered for per compalint/per day |
| 2 | Supply and fixingin replacement of LED lamp 07to 15 watt watts 230 voltscompleteall as specified and as directed by Engineer-in-Charge. |
| 3 | Supply and fixing in replacement lamp holder suitable for LED lamp as per site requirement completeall as specified and as directed by Engineer-in-Charge. |
| 4 | Supply and fixing in replacement bell electric Ding Dong type 230 volts completeall as specified and as directed by Engineer-in-Charge. |
| 5 | Supply and fixing Switch piano flush button type single pole one/Two way/Bell push5 amps 240 volts completeall as specified and as directed by Engineer-in-Charge. |
| 6 | Supply and fixingin replacement, for socket outlet 2 in 1, 5 pin, 5 Amps flush type completeall as specified and as directed by Engineer-in-Charge. |
| 7 | Supply and fixingin replacement, for switch flush type 15 Amps, 240 Volts single pole white finish completeall as specified and as directed by Engineer-in-Charge. |
| 8 | Supply and fixingin replacement of socket outlet 2 in 1, 3 pin, 5 & 15 A multi purpose flush type 240 V white finish completeall as specified and as directed by Engineer-in-Charge. |
| 9 | Supply and fixing in replacement of switch socket combination, 5 amps 5 pin flush type, 230 volts.white finish completeall as specified and as directed by Engineer-in-Charge. |
| 10 | Supply and fixing in replacement of switch socket combination,5 and 15 amps multi purpose 5 in 1 flush type, 230 voltscompleteall as specified and as directed by Engineer-in-Charge. |
| 11 | Supply and fixing in replacement of switch Piano modular type, 6 Amp, one way completeall as specified and as directed by Engineer-in-Charge. |
| 12 | Supply and fixing in replacement of switch Piano modular type, 16 Amp, one way completeall as specified and as directed by Engineer-in-Charge. |
| 13 | Supply and fixing in replacement of bell push Piano modular type, 6 Amp, 230 volts completeall as specified and as directed by Engineer-in-Charge. |
| 14 | Supply and fixing in replacement of socket outlet modular type, 2/3 pin, 6 Amps, 230 volts completeall as specified and as directed by Engineer-in-Charge. |
| 15 | Supply and fixing in replacement ofsocket outlet modular type but 2/3 pin, 6/16 Amps, 230 volts completeall as specified and as directed by Engineer-in-Charge. |
| 16 | Supply and fixing in replacement of ceiling rose, surface backlite, 65 x 20 mm three terminal ISI Marked completeall as specified and as directed by Engineer-in-Charge. |
| 17 | Supply and fixing in replacement plastic laminated top sheet cover 3 mm thick of size 5\"x5\" all as required at site including drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box completeall as specified and as directed by Engineer-in-Charge. |
| 18 | All as per item no 17, but of size8\"x5\"completeall as specified and as directed by Engineer-in-Charge. |
| 19 | All as per item no 17, but of size11\"x9\" completeall as specified and as directed by Engineer-in-Charge. |
| 20 | All as per item no 17, but of size 13\"x11\" completeall as specified and as directed by Engineer-in-Charge. |
| 21 | Supply and fixing in replacement of PVC rectangular switch Board for mounting switches, sockets etc with 3mm thick plastic laminated sheet cover of size 100mmx100mm and 50mm deep , 240 volt completeall as specified and as directed by Engineer-in-Charge. |
| 22 | All as per item no 21, but of size 175mmx100mm and 50mm deep , 240 volt completeall as specified and as directed by Engineer-in-Charge. |
| 23 | All as per item no 21, but of size200mmx150mm and 50mm deep , 240 volt completeall as specified and as directed by Engineer-in-Charge. |
| 24 | All as per item no 21, but of size250mmx200mm and 50mm deep , 240 volt completeall as specified and as directed by Engineer-in-Charge. |
| 25 | All as per item no 21, but of size 350mmx300mm and 50mm deep , 240 volt completeall as specified and as directed by Engineer-in-Charge. |
| 26 | Material and labour for servicing of exhaust fan upto 300 mm sweep with painting and rewinding, change of bearing if defected, louvered/shutters including taking down and refixing after satisfactory repaired complete all as directed by Engr-In-Charge. |
| 27 | Material and labour for servicing of exhaust fan above 300mm and upto 450mm sweep with painting and rewinding, change of bearing if defect, louvered complete all as dorected by Engr-In-Charge. |
| 28 | Supply and fixing in replacement capacitor 3.15/4 mfd 240 volts for fans make Epcos /Matrix (oil Filled ) completeall as specified and as directed by Engineer-in-Charge. |
| 29 | Taking down and refixing/relocation of exising tube light fitting, wall bracket or bulkhead fitting including connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 Sqmm 3 core all as per direction or specified by the Engr-in-charge |
| 30 | Supply and fixing in replacement of LED bulk head fitting PlasticBody , heat resistant,with specially designed gasketin and including LED lamp 10 wattcomplete all as per directed by Engr-in-charge. |
| 31 | Supply and fixing in replacementPolycarbonate LED lighting fixture of size 25 watt(4\") complete withall accessories prewiredand connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or completeall as specified and as directed by Engineer-in-Charge. |
| 32 | All as per srl item No 31 here-in-before but10 watt (2\") completeall as specified and as directed by Engineer-in-Charge. |
| 33 | Supply and fixing in replacement ofultra mordern recess mounting flat panel luminaires (2\"x2\"), 36 Watt LED, 6000k with seprate electronic driver & high brightness SMD LEDs including lamp and complete withall accessories prewiredand connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor all as required at site or completeall as specified and as directed by Engineer-in-Charge. |
| 34 | Supply and fixing in replacement energy saving flood light luminaire high power COB LED as light source withprotection IP66 of 50 watt LED with inbuilt surge protection complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size completeall as specified and as directed by Engineer-in-Charge. |
| 35 | Supply and fixing Electronic Meter 10-60 amps Single phase tamper proofwith Class 1 accuracy Optical port,LED Indication for earth leakage ,Elegant Polycarbonate Enclosure, anti tamper features, Electromagnetic compatible & 6 digit Display completeall as specified and as directed by Engineer-in-Charge. |
| 36 | Supply and fixing in repair/replacement voltage surge protector, 230/240 volts AC, 1.4 KV protection level type II with indicatordouble pole (two modules)with rupturing cacpacity 40 KA including makeing connection and providing thimble for out going cables and enclosure completeall as specified and as directed by Engineer-in-Charge. |
| 37 | Material and labour for testing of old earthing using calibrated earth tester & submitting result to engr -in -charge. Earthing which showing much more results as specified in IS rule and disconnetivity should be replaced with new earthing items are considered as below completeall as specified and as directed by Engineer-in-Charge.Note : (i) Watering of earthing with 2 Buckets (30Ltrs) water mixed with salt (total 5 Kg) shall be carried outone day before the testing & the cost of the same shall deemed included in unit rate quoted. |
| 38 | Taking down old unserviceable/deteriorated batten/PVC conduit point wiring from existing place i.e.light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets, ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1 : 3) or plaster of Peris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge. |
| 39 | Taking down main switch/DB/ changeover/AC box of any capacity including fixing accessories of single/three phase completeall as specified and as directed by Engineer-in-Charge. |
| 40 | Taking down old/unserviceable aluminium/coppersubmain wiring off sizes completeall as specified and as directed by Engineer-in-Charge. |
| 41 | Material and labour for in replacement of concealed point wiring on wall and surface on ceiling/roof with necessary fixing arrangements withPVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dollyand Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mountingfittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 0.75 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following:-(a) One light, fan, call bell, 5 Amp independent socket point controlled by one switch completeall as specified and as directed by Engineer-in-Charge. |
| 42 | All as per item No 41 but One socket point controlled by one switch on same board completeall as specified and as directed by Engineer-in-Charge. |
| 43 | All as per item No 41 here-in-before but for power point wiring with 2.5 SqmmPVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead completeall as specified and as directed by Engineer-in-Charge. |
| 44 | All as per item Srl No 41 here-in-before butpoint wiring in surface with casing & caping complete all as specified and directed by Engineer-in-Charge for the following:-(a) One light, fan, call bell point, 5 Amp independent socket point controlled by one switch completeall as specified and as directed by Engineer-in-Charge. |
| 45 | All as per item No 44 but One socket point controlled by one switch on same board completeall as specified and as directed by Engineer-in-Charge. |
| 46 | All as per item No 44 here-in-before but for power point wiring with 2.5 SqmmPVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead completeall as specified and as directed by Engineer-in-Charge. |
| 47 | Supply and fixing in replacement sheet metal enclosure , 32A single pole and neutral with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB 20 Amp fixed properly complete all as directed by Engineer-in-Charge. |
| 48 | S&F in replacement sheet metal enclosure VTPN MCCB DB 4way, 415 V (vertical type) with bus bar double door type IP 43 - IK 09 for DB including MCBs & MCCB100 Amps (as incomer)to be used, fixed properly on / in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires completeall as specified and as directed by Engineer-in-Charge. |
| 49 | Supply and fixing in replacement double door metallic sheet metal enclosure for DB when MCBs to be used TPNL, 4 ways, 415Volts (horizontal type)with 200 Amps rated bus bar suitable for TPN MCB/ 4 pole Isolator fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires completeall as specified and as directed by Engineer-in-Charge. |
| 50 | Supply and fixing in replacement double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires completeall as specified and as directed by Engineer-in-Charge. |
| 51 | All as per item no 50, but size 4 way completeall as specified and as directed by Engineer-in-Charge. |
| 52 | All as per item no 50, but size 2 way without busbar completeall as specified and as directed by Engineer-in-Charge. |
| 53 | Supply and fixing in replacement MCB SP 240 volt 6 Amp to 32 Amps 10 KA capacity having C-curve characteristics connected with suitable lugs completeall as specified and as directed by Engineer-in-Charge. |
| 54 | All as per item no 53, but SP 40-63 Amps completeall as specified and as directed by Engineer-in-Charge. |
| 55 | All as per item no 53, but SPN 16-40 Amps completeall as specified and as directed by Engineer-in-Charge. |
| 56 | All as per item no 53, but SPN 40-63 Amps completeall as specified and as directed by Engineer-in-Charge. |
| 57 | All as per item no 53, but TP 40-63 A 415 V completeall as specified and as directed by Engineer-in-Charge. |
| 58 | All as per item no 53,- but TPN 40-63 Amps completeall as specified and as directed by Engineer-in-Charge. |
| 59 | Supply and fixing in replacement heavy duty exhaust fan AC single phase 230/240 V of size 300 mm sweep 1400 RPMwith louver & shutter including necessary grouting on wall complete and making good the wall surface after fixing of exhaust fan all as specified and directed by the Engr-in-charge. |
| 60 | Supply and fixing in replacement MCCB 100 Amps, 3 Pole, 415V, 25 KA, fixed type completeall as specified and as directed by Engineer-in-Charge. |
| 61 | Supply and fixing in replacement MCCB 125 Amps, 3 Pole, 415V, 25 KA, fixed type completeall as specified and as directed by Engineer-in-Charge. |
| 62 | Supply and fixing in replacement MCCB 160 Amps, 3 Pole, 415V, 36 KA, thermal, magnetic adjustable type completeall as specified and as directed by Engineer-in-Charge. |
| 63 | Supply and fixing in replacement MCCB 200 Amps, 3 Pole, 415V, 36 KA, thermal, magnetic adjustable type completeall as specified and as directed by Engineer-in-Charge. |
| 64 | Material and labour for in replacement of sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 4 sqmm drawn in new/exisitng MS/PVC conduitwith 4 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete excluding rigid PVC conduit completeall as specified and as directed by Engineer-in-Charge. |
| 65 | All as per item No 64, but size 6 sqmm completeall as specified and as directed by Engineer-in-Charge. |
| 66 | Material and labour for in replacement sub main wiring with foursingle core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in new/existing PVC conduitwith one run of6 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete. Note for item No 64 to 65: New PVC Conduit & cutting chasing will be measured and paid separately under relevent item here-in-after |
| 67 | Materil and labour for replacement of Rigidmetallic medium20mm dia PVC conduit ISI marked in concealed position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddlers, pipe hooks etc fixed properlyin concealedor surface position for laying of submain wiring or telephone wire etc all as specified and directed by Engineer-in-Charge |
| 68 | All as per item No. 67 above butmetallic medium25 mm dia PVC conduit ISI markedcompleteall as specified and as directed by Engineer-in-Charge. |
| 69 | Materil and labour for Cutting chases in brick walls, pinning in at the depth of 10cm, making good to facings where required and pointing in cement mortar 1:3 cutting chases for concealed conduit wiring and making good and plastering the surface with cement or plaster of peris and matching with same colour scheme, cuttingnot exceeding 10cmgirth completeall as specified and as directed by Engineer-in-Charge. |
| 70 | Materil and labour for fixing Boxes junctions, plastic, round four terminals in existing/new PVC conduit fitting completeall as specified and as directed by Engineer-in-Charge. |
| 71 | Materil and labour for replacement of flameproof concealed point wiring on wall and surface wiring on ceiling / roof with necessary fixing arrangements with stranded PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including 16 gauge stove enameled ERW rigid steel conduit (metallic) not less than 19 mm dia with all MS conduit accessories/ fittings such as, bends, tee, elbow excludingjunction boxes etc including PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for one light, fan point controlled by one switch completeall as specified and as directed by Engineer-in-Charge. |
| 72 | All as per item No 71 here-in-before but for power point wiring with 2.5 SqmmPVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead completeall as specified and as directed by Engineer-in-Charge. |
| 73 | Supply and fixingin replacement16 Amp flame proof weather proof switch Socket and plug combined in LM 6 cable termination box, 250 V, 2P + Earth completeall as specified and as directed by Engineer-in-Charge. |
| 74 | Supply and fixingin replacement flame proof weather proof threaded type junction box LM 6 aluminium alloy completeall as specified and as directed by Engineer-in-Charge. |
| 75 | Supply and fixingin replacement flame proof weather proof metallic hose conduit 3/4 \" dia300 mm longcompleteall as specified and as directed by Engineer-in-Charge. |
| 76 | Supply and fixingin replacementflameproof double compression brass cable gland 3/4\" dia complete with nipplescompleteall as specified and as directed by Engineer-in-Charge. |
| 77 | Supply and fixingin replacementFlame proof weather proof switch with cable termination in LM 6 cable termination box aluminium alloy housing 16 Amp, single pole 250 volts completeall as specified and as directed by Engineer-in-Charge. |
| 78 | Supply and fixingin replacement Fluorescent tube light fitting, 1x36 watt flameproof type FLP-WP IP-65 made of aluminium alloy LM6 with electronic ballast, bipen holders, connector block etc complete with all accessories prewired and includidnt connecting up with twin core twisted flexiblecopper conductor cable with suitable sizecomplete all as specified and directedMake: Bajaj or equivalent inCG/ Sudhir/FCG./Shyam Switchgears Pvt ltd completeall as specified and as directed by Engineer-in-Charge. |
| 79 | Supply and fixing5 Watt LED torch with high intensity focused beam with twin switching mode complete all as specified and directed by Engr-in-charge. Make : Havells Cat Part No. LHEXAOPFUN1G005 or equivalent completeall as specified and as directed by Engineer-in-Charge. |
| 80 | Supply and fixingin replacement9 Watt, 6500 K LED round/oval slim compact aluminium die cast edge lit panel suitable for recess mounting round fixture with Opal diffuser and separate electronic driver complete all as specified and directed by Engr-in-charge. Make : Havells Cat part No. LHEBADP7IZ1W009 or equivalent completeall as specified and as directed by Engineer-in-Charge. |
| 81 | Supply and fixingin replacementLED panel drivers suitable for 9/12/15/18/36 watt recessed mounting luminaries with universal connectors complete all as specified and directed by Engr-in-charge. Make : Havells Cat part No. LSSLNW0171 or equivalent completeall as specified and as directed by Engineer-in-Charge. |
| 82 | Supply and fixing in 1100 volts grade heavy duty cable PVC insulated aluminium staranded conductor , served with inner sheathed PVC tape and overall PVC sheathed in service connection one twin core flat or circular of size 10 sqmm x 2core Material and labour |
| 83 | Material and labour for dismantling from insulators including taking down ACSR conductor any size from overhead lines completeall as specified and as directed by Engineer-in-Charge. |
| 84 | Material and labour for dismantling earth wire any size from eye hooks/insulators etc fromoverhead lines completeall as specified and as directed by Engineer-in-Charge. |
| 85 | Material and labour for dismantling insulator any type and any size fromover head linescomplete completeall as specified and as directed by Engineer-in-Charge. |
| 86 | Supply and stringing ACSR conductor any size toover head lines, stretching properly to achieve proper sag including binding to insulators using GI/aluminium binding wire all as required at site or directed by Engr-in-Charge. |
| 87 | Supply and fixing in replacement ofgalvanized steel wire of size 4mm dia toover head line as continuous earth or fabrication of guarding cradles all as specified and directed by Engineer-in-Charge. |
| 88 | Material and labour for unbinding from insulators ACSR conductor any size ofover head line for repairs. Restretching of ACSR conductor to achieve proper sag and rebinding to the insulators using aluminium/GI binding wire all as required at site or directed by Engineer-in-Charge. |
| 89 | All as per item srl No 88 abovebut GI wire completeall as specified and as directed by Engineer-in-Charge. |
| 90 | Material and labour for cutting/trimming tree branches aroundoverhead lines to a distance of 01 meter both side from overhead lines or poles after taking proper shut down of electric supply from MES all as directed by Engr-in-charge. |
| 91 | Material and labour in replacement of Stay assembly set complete with accessories like stay rod/strand/plate ,loop type insulator, clamps, excavation, concreate etc for LT/HT pole any type using necessary T&P as required on site and as directed by Engineer-in-charge. |
| 92 | Material and labour in replacement of for pin type porcelain, vitreos, white, brown or green insulators including one galvanized mild steel spindle, two galvanised iron washers and one galvanised iron nut 100mm height, 65mm diacompleteall as specified and as directed by Engineer-in-Charge. |
| 93 | Material and labour in replacement of for loop type insulator, vitreous porcelain white brown or green small size with overall dimensions 65x90mm, clearance of hole 16mmcompleteall as specified and as directed by Engineer-in-Charge. |
| 94 | Material and labour in replacement of for loop type insulator, vitreiys porcelain white brown or green largesize with overall dimensions 90x140mm, clearance of hole 25.5mmcompleteall as specified and as directed by Engineer-in-Charge. |
| 95 | Supply and fixing in replacement of aluminium strip 25x3mm complete with saddles/ insulators made out of PVC or fibre and fixing screws for roof conductor/down conductor including welding or brazing for joints all as required at site or directed by E-In-Charge. |
| 96 | All as per item no 95 above but copper strip 20x3mm complete all as required at site or directed by E-In-Charge. |
| 97 | Supply and fixing in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipeor fixed to poles or any other indicated situation for loop earthing etc as required 4mm dia galvanized iron or steel wire complete and all as specified and as directed by Engr-in-charge. |
| 98 | Supply and fixing in replacementoutdoor intergal fantasy decorative LED bollard with IP protection 65post top lantern suitable for landscape lightingin andincluding 08 watt LEDwith all complete fixing accessories and suitable arrangement as required at site complete all as specified and directed by Engr-in-charge. |
| 99 | Supply and fixing in replacement of street light time switch of size 50 x 50 x 30 cm made out of MS sheet 1.6 mm thick factory fabricated duly powder coated with front door operable heaving pressure lock suitable for and including the followings :- (i) Street light time switch multi functional digital for automatic switching on & offof street lights at a preset time model Astrorex D-21 Cat Pt No 004764 (ii) Air break contactor AC 415 volts, 50 HZ 3 phase 70 A with operating coil voltage 220 volts conforming to cat pt No CE 15 KN 3 of BCH or cat pt No LCI D-50 of Schneider - 01 No (iii) Bakelite fuse base and carrier with HRC fuses 63 amps 415 V Make : L&T/GE– 04 Nos(v) Bakelite fuse base and carrier with HRC fuses 5 amps 230 V(iv) All accessories pre wired with suitable size copper conductor cable including making necessary arrangements for fixing to wall / pole / panel all as required at site or directed. |
| 100 | Supplying including layingtesting and connecting in replacement ofXLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electrical cable with aluminium conductor, 1100 volts grade, cross-sectional area with suitable lugs of following sizes:-(a) 16 sqmm 2 core completeall as specified and as directed by Engineer-in-Charge. |
| 101 | All as per item No 100 but 25 sqmm 2 core completeall as specified and as directed by Engineer-in-Charge. |
| 102 | All as per item No 100 but 35 sqmm 3.5 core completeall as specified and as directed by Engineer-in-Charge. |
| 103 | All as per item No 100 but 50 sqmm 3.5 core completeall as specified and as directed by Engineer-in-Charge. |
| 104 | All as per item No 100 but 70 sqmm 3.5 core completeall as specified and as directed by Engineer-in-Charge. |
| 105 | All as per item No 100 but 95 sqmm 3.5 core complete and all as specified and as directed by Engr-in-charge. |
| 106 | All as per item No 100 but 120 sqmm 3.5 core complete and all as specified and as directed by Engr-in-charge. |
| 107 | Material and labour for excavation in trenches in any type of soil, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, laying of cables and getting out complete all as specified & as directed by Engineer-in-charge. |
| 108 | Material and labour for returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm each layer complete all as specified & as directed by Engineer-in-charge. |
| 109 | Material and labour for removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified & as directed by Engineer-in-charge. |
| 110 | Material and labour for sand cushioning to under ground cable 8 cm thick layer below the cable and 15cm thick above the cable complete and complete all as specified & as directed by Engineer-in-charge. |
| 111 | Material and labour for brick protection with well burnt sub class ‘B’ brick a butting each other( width wise) across the cable laid in trenches complete all as specified & as directed by Engineer-in-charge. |
| 112 | Material and labour in replacement of tubing GI light grade 50 mm bore for cable protection laid in ducts, fixed to wall or poles including fixing arrangement all as required and directed by Engineer-in-Charge. |
| 113 | All as per srl item No 112 here-in-beforebut of size 40 mm bore complete all as specified & as directed by Engineer-in-charge.. |
| 114 | Supply and fixingin replacement of maintenance free battery 12 Volt , 150 AH dry type with suitable copper connecter terminal lead (positive and negative) for DG set 62.5 KVA complete all as spcified by Engr- In-Charge. |
| 115 | Supply and fixing in replacement of maintenace free battery 12 Volt , 180 AH, dry typewith suitable copper connecter terminal lead (positive and negative) for DG set 82.5 KVA complete all as spcified by Engr- In-Charge. |
| 116 | Supply and fixing in replacement of portable one battery charger setto accommodatewith copper connecting +ve/-ve lead terminal, voltage control regulator setector switch of 12 Volt, 24 V,36 V,current control regulator switch, amps meter, electronic fuse, push to reset , AC mains on/off buttons complete as factory made Make Autonic india or equvilent makeall as specified by Engr-In-Charge. |
| 117 | Supply and fixingin replacement of neon indicater lamp set of three (RYB) PVC body with contact block and assembly to be fixed on exsisting panal board complete all as spcified by Engr- In-Charge. |
| 118 | Supply and fixing in replacement ofPVC 1100 volt LT phase seperator/spacer for 3 phase 4 wire system incl taking down U/S seperater all as specifiedby E-in- Charge |
| 119 | Supply and fixing in replacement of PVC 1100 Volts LT phase seperator/spacer for 1 phase 2 wire system incl taking down u/s seperater all as specifiedby Engr-in- Charge |
| 120 | Supply and installin replacement ACB4 Pole, 50 KA, 415 volt with thermal magnetic release, adjustable, manual fixed type of capacity 630 Amp complete all as specified and directed by Engr-in-Charge. |
| 121 | Material and labour for Danger Notice Plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with white letter, figures and conventional skull & bones in signal red colour and fixed with MS clamps, nuts and bolts of approved size, for LT, 20x15cm size complete all as specified & as directed by Engineer-in-charge. |
| 122 | Supply and fixing in replacement ofsingle core copper multistrandred conductor flexible PVC Insulated heavy duty Industrial cable (unsheathed) 1100 volts size 16 sqmm ( per 100 RM roll) complete all as specified & as directed by Engineer-in-charge. |
| 123 | Supply and fixing in replacement of MCCB 4 Pole 415 Volts with rupturing capacity 16 KA 100 Amps fixed type complete all as specified & as directed by Engineer-in-charge. |
| 124 | All as per item no 123 above but125 Amps fixed type complete all as specified & as directed by Engineer-in-charge. |
| 125 | Supply and fixing in replacement of MCCB 4 Pole 415 Volts with rupturing capacity 35/36 KA 160 Amps Adjustable type thermal Megnaticrelease complete all as specified & as directed by Engineer-in-charge. |
| 126 | Material and labour in replacement of earthing complete with galvanized cast ironearth plate electrode 600x600x6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below ;normal ground level ) withtop edge of earth plate not less than 1.5 Mtr below normal ground level connected to galvanized iron strip 32x6 mm as earth lead by means of bolts, nuts washers and check nutsof steel/GI duly protected with 40 mm bore light grade pipe upto main board , 20mm bore watering pipe light gradewith CI/MS funnel and wire mesh including excavation, earth work in any type of soil and removing the surplus soil to a distance not exceeding 50 Mtr, add charcoaldust and common salt after mixing with BFC (Back Fill Compound) inadeqate quantity as recommended by the manufacturer oras diirectred by the Engr-in-charge all as shown in electrical plate No. 03 of SSR part-I 2009 having pit in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40x40x6mm grouted in PCC pit for CI cover of required size, funnel withwire mesh complete and all as specified and as directed by Engr-in-charge. |
| 127 | All as per item srl No 126 abovebut using GI wire 4mm thick complete all as specified & as directed by Engineer-in-charge.Note for item No 126 & 127 : If the earth result of the earthing found more than 4 Ohms then new earthing will be executedby the contractor without any extra cost for the result upto 4 ohms |
| 128 | Material and labour for dismentling taking out broken/worn out steel pole of 8.5 to 9.0 mtr long and kepping aside for refixing including conductor, insulator etc or carrying to store for credit complete all as specified & as directed by Engineer-in-charge. |
| 129 | Labour only for re-fixing ofsteel tubular swaged pole complete with cast ironbase plate , painted internally with a coat of bituminous paint and externally one primer coat, one under coat and one finishing coat of aluminium paint as specified type(9 mtr long) with conductor and insulators complete all as specified & as directed by Engineer-in-charge. |
| 130 | Supply and fixing in replacement of Steel tubular swaged pole complete with cast iron plate, finial taper plug, bolts, nuts & screws as specified of type 410 SP-31 of 9 meter long including applying two coats of black bituminous paint throughout internally and externally up to the planting depth and remaining portion of the exterior painted with one coat of red oxide primer over two coats of aluminium paint and number marking on pole complete all as specified & as directed by Engineer-in-charge. |
| 131 | Material and labour for cement concrete in foundations, filling and mass concrete type D2 1:4:8 with 40mm graded aggregate for pole bedding. |
| 132 | Material and labour for cement concrete in foundations, filling and mass concrete type C2 1:3:6 with 40mm graded aggregate for foundation of pole complete all as specified & as directed by Engineer-in-charge. |
| 133 | Material and labour for cement concrete in foundations, filling and mass concrete type B2 1:2:4 with 40mm graded aggregate for coping of pole complete all as specified & as directed by Engineer-in-charge. |
| 134 | Material and labourfor scraping of old paint from thesteel tubular/PCC pole 09/11 mtr height with out removing accessories and preparationof surfaces for repainting.Repainting the pole with one coat of alternative blackand yellow (existing colour) straps of 30 cm each upto 1.5 mtr height using synthetic enamel paint . Repainting the remaining pole and iron parts i.e U clamps, channels etc above 1.5 mtr height by applying one coat of aluminium paintincluding writing Pole Nos. with Black paintall as per specified at site and directed by Engineer-in-Charge. |
| 135 | Material and labourin replacement of earthing complete with copper earth plate600x600x3.15 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below ;normal ground level ) withtop edge of earth plate not less than 1.5 Mtr below normal ground level connected to copper strip 20X3 mm as earth lead by means of bolts, nuts washers and check nutsof copper/ bronze duly protected with 40 mm bore light grade pipe upto main board , 20mm bore watering pipe light gradewith CI/MS funnel and wire mesh including excavation, earth work in any type of soil and removing the surplus soil to a distance not exceeding 50 Mtr, add charcoaldust and common saltas diirectred by the Engr-in-charge all as shown in electrical plate No. 03 of SSR part-I 2009 having pit in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40x40x6mm grouted in PCC pit for CI cover of required size, funnel withwire mesh complete and all as specified and as directed by Engr-in-charge. Note : If the earth result of the earthing found more than 1 Ohm then new earthing will be executedby the contractor without any extra cost for the result upto 1 ohm. |
| 136 | Supply and fixing in replacement of bus bar box suitable for 200 Amps load of size 450x325x214mm IP65 with internal 4 Nos Copper Strip 200A (30x10mm) and fixing in position with nut, bolt, clamp, disconnection and reconnection of service wire/UG cabel in boxincl dismentling bus bar box at sitecomplete and all as specified and as directed by Engr-in-charge. |
| 137 | Supply and fixing in replacement of street light pole box suitable for fixing on LT pole size 200x160x98 mm 25 sqmm Terminal block 4 Nos, 4 sqmm Earth terminal 1 No with suitable gland , door and locking arrangment and suitable for terminal single phase including MCB 6-10A SP and fixing in position with nut, bolt, clamp, disconnection and reconnection of service wire/UG cabel in boxincl dismentling old street pole boxcomplete all as specified & as directed by Engineer-in-charge. |
| 138 | Supply and fixing in replacement of onload change overswitch 125 Amps, 4 pole, 415 V including making necessary connections on wall/LT panels etc with suitable size of thimbles, cable glands and jointing material etc all as specified and directed by the Engr-in-charge. |
| 139 | All as per item no 138 above but100 Amps,all as specified and directed by the Engr-in-charge. |
| 140 | Supply only PVC insulation LT tape of size 15M x 1.8cm x 0.125 mmcomplete all as specified & as directed by Engineer-in-charge. |
| 141 | Supply only EPR self amalgamating tape of size 38mm x 10 Mtr complete all as specified & as directed by Engineer-in-charge. |
| 142 | Material and labour for disconnecting the Split type Air conditioner cap 1.5/2 Ton from Outer unit and repair the followings as required on site & as directed by Eng-in-charge :-(a) Servicing the Split type AC cap 1.5/2 Ton, Cleaning of condenser coil unit from Stand and inner unit complete all as specified & as directed by Engineer-in-charge. |
| 143 | As per item no 142 here-in-before but Vacuum the compressor unit and testing of leakage and charging Gas of F-22 and topup the Gas F-22complete all as specified & as directed by Engineer-in-charge. |
| 144 | As per item no 142 here-in-before but Replacement of capacitor 45 mfd. complete all as specified & as directed by Engineer-in-charge. |
| 145 | As per item no 142 here-in-before but Replacement of filter dryer complete all as specified & as directed by Engineer-in-charge. |
| 146 | As per item no 142 here-in-before but Replacement of sealedComppresser Unit as per existing make as per sample complete all as specified & as directed by Engineer-in-charge. |
| 147 | As per item no 142 here-in-before but Taking out the defective eletronic circuit board or PCB unit indoor unit of split type AC and supply and fix eletronic circuit board for split AC of capacity 1.5 /2TR of anyexixting make and model or as per required at sitecomplete all as specified & as directed by Engineer-in-charge. |
| 148 | As per item no 142 here-in-before but Taking only burnt/unserviceable blower motor and replace the same with new (Company sealed) blower motor as per exiting size, specification and Make suitable forAC of capacity 1.5/2 Ton of any make and model as applicable and connectnig up all the system all as directed by the Engr-in-Charge |
| 149 | As per item no 142 here-in-before but Taking out unserviceable evaporator coil and replace the same with new (company sealed) evaporator coil as per size, secification and make suitable for Ac of 1.5/2 ton of any make & model as applicable and connecting up all system with and including charging of refrigment (F-22) and testing complete to the satisfaction of the Engr-in-Charge |
| 150 | As per item no 142 here-in-before but Taking out unserviceable condenser coil and replace the same with new(company new) condenser coil as per exiting size, secification and make suitable forAc of 1.5/2 ton of any make as applicable and up all the system eith and including charging of refrigrant (F-22) and testing complete to the satisfaction of the Engr-in-Charge. |
| 151 | Material and labour for Disconnecting the Deep freezer cap 210/300 Ltrand refrigerator cap 165 to 310 Ltrs andrepair thefollowings:-(a) Servicing the Refrigerator ,Deep freezer, Cleaning of condenser coil unit from Stand and inner unitcomplete all as specified & as directed by Engineer-in-charge. |
| 152 | As per item no 151 here-in-before but Taking out unserviceable condenser coil and replace the same with new(company new) condenser coil as per exiting size, secification and make suitable for refrigerator of capacity 180/310 ltrs of any make as applicable with and including charging of refrigerant gas (F-12) and testing complete to the satisfaction of the Engr-in-Charge. |
| 153 | As per item no 151 here-in-before but Vacuum the compressor unit and testing of leakage and charging Gas (F-12) complete all as specified & as directed by Engineer-in-charge. |
| 154 | As per item no 151 here-in-before but Replacement of capacitoror starting relay as suitable for existing capacity complete all as specified & as directed by Engineer-in-charge. |
| 155 | As per item no 151 here-in-before but Replacement of filter dryer pencil of any size complete all as specified & as directed by Engineer-in-charge. |
| 156 | As per item no 151 here-in-before butReplacement of cooling fan with electric motor complete all as specified & as directed by Engineer-in-charge. |
| 157 | As per item no 151 here-in-before but supply and fixingin replacement of compressor(sealed unit) as per existing size specification and make suitable for refrigerator of capacity 180/310 ltrs of any make as applicable and connecting up all the system with and includingRelay & OLP and Re- gas charging of refrigerantand testing complete to the satisfaction of the Engr-in-Charge. |
| 158 | As per item no 151 here-in-before but refrigerator of capacity310 ltrs of any make complete all as specified & as directed by Engineer-in-charge. |
| 159 | Material and labour for replacement of defective componants /accessories suitable for refrigerator of capacity 165 ltrs to 310 ltrs of any model and make as applicable and testing complete as directed by the Engr-in-Charge(a) Freezer complete with freezer door braket suitable for refrigerator of capacity 165 ltrs. |
| 160 | As per item no 159 here-in-before but suitable for 280 / 310 ltrs complete all as specified & as directed by Engineer-in-charge. |
| 161 | As per item no 159 here-in-before butIce tray PVC / Plastic for all modelscomplete all as specified & as directed by Engineer-in-charge. |
| 162 | As per item no 159 here-in-before butChiller tray suitable for refrigerator of capacity 165 litrs complete all as specified & as directed by Engineer-in-charge. |
| 163 | As per item no 159 here-in-before but Thermostat control switch complete with knob and box suitable for refrigerator of capacity 165 ltrs to 310 ltrs complete all as specified & as directed by Engineer-in-charge. |
| 164 | As per item no 159 here-in-before but Table top for refrigerator suiatable foras per exiting size and colour complete all as specified & as directed by Engineer-in-charge. |
| 165 | Material and labour for replacement of unserviceable components/ parts such as power circuit board (PCB), time relay, socket outlet, regualtor /toggle switch,Voltmetre , Indicator lamp, circuit wiring fuse unit etc includingrewinding of transfarmor &painting voltage stablizer extamally with two coats of synthetic enamal paint after preparation of old painted steel surface and testing all complete for stablizerup to 10 KVA capacity complete all as specified & as directed by Engineer-in-charge. |
| 166 | Supply and fixing in replacement heating element any type 1.5/2.0 KW 240 Volts, ISI marked for water heater storage type complete all as specified & as directed by Engineer-in-charge. |
| 167 | Supply and fixing in replacement thermostat switch 0 to 100°C , 240 volts suitable for water heater storage type any make complete all as specified & as directed by Engineer-in-charge. |
| 168 | Supply and fixing in replacemnent of Syphon assy any type for water heater storage type upto 25/50 ltr cap complete all as specified & as directed by Engineer-in-charge. |
| 169 | Supply and fixing in replacemnent of Inner copper tank any cap for water heater storage type upto 25/50 ltr cap complete all as specified & as directed by Engineer-in-charge. |
| 170 | Supply and replacement outer body suitable for 25/50 ltr geyser made out of MS sheet factory made complete with fixing bracket matching with existingcomplete all as specified & as directed by Engineer-in-charge. |
| 171 | Supply and replace glass woolof 25/50ltrs capacity geysercomplete all as specified anddirected by Enginner-in-Charge. |
| 172 | Supply and replace indicator lamp round/square type suitable for geyser 25/50 ltr all as per sample AC 230 Volt complete all as specified & as directed by Engineer-in-charge. |
| 173 | Supply and replace hot and cold PVC connection 15mm dia complete with brass flair nuts at both ends complete all as specified & as directed by Engineer-in-charge. |
| 174 | Supply and replacebrass pressure release valve chromium platedsuitable for geyser 25/50 ltr capacitycomplete all as specified & as directed by Engineer-in-charge. |
| 175 | Supply and fixing anchor bolt 12mmX100mm long complete all as specified & as directed by Engineer-in-charge. (Note:- Anchor bolt shall be grouted with hammer drill only) |
| 176 | Supply and replace bottom cover plate of geyser of capacity 25/50 ltr complete with MS screw complete all as specified & as directed by Engineer-in-charge. |
| 177 | Supply and fixing in replacementStop valve, cast copper alloy, screwed down,m high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for bore dia of pipe 15mm complete all as specified & as directed by Engineer-in-charge. |
| 178 | Supply and fixing in replacement plug top 3 pin 6 amps AC 240 Volts complete all as specified & as directed by Engineer-in-charge. |
| 179 | Supply and fixing in replacement plug top 3 pin 16 amps AC 240 Volts complete all as specified & as directed by Engineer-in-charge. |
| 180 | Supply and fixing in replacement cord flexible PVC insulated and over all sheathed, 3 core, flexible copper conductor of size 1.50 sqmm, cut to size all as required at site complete all as specified & as directed by Engineer-in-charge. |
| 181 | As per item no 180 here-in-beforebut size 2.5 sqmm complete all as specified & as directed by Engineer-in-charge. |
| 182 | Supply and fixing in replacement cord flexible PVC insulated, 2 core, (22/0076) flexible copper strandred conductor of cut to size for connection ceiling rose to fittings and fixture complete all as specified & as directed by Engineer-in-charge. |
| 183 | Supply and fixing in replacement of building security light fitting of new generation energy saving and environmental friendly long life versatile pressure die cast aluminium housing IP66LED lumanaire with high power LED 25 watt as light source with toughned glass complete all as specified and directed by Engr-in-charge, |
| 184 | Supply and fixing in replacement energy efficientflame froof , heavy duty high speed exhaust fan 380 mm(15\") sweep, with louver shutter, matel body rust proof inbuilt safety grill, single phase 230 volts 50 Hz AC,totally enclosed heavy duty motor with die cast alumn rotor mounted on two ball bearings complete with louvers & shutters,,including making circular holes suitable for fixing of 380mm sweep exhaust fans by cutting the wall any thickness/ required circumstances for exhaust of air and including grouting of rag bolts and nuts complete including finishing of disturbed surfaces by using cement mortar 1:3 complete and connecting electrically using 3 core 0.75sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site and directed by the Engineer-in-Charge. |
| 185 | Supply, fixing Installing and testing ISI marked energy efficient, water heater storage type, electricaly operated, single phase, 50Hz (5 star rating), complete of 25 Ltr capacity with and including supply and fixing, wire armoured 450 mm long, 15 mm dia, brass coupler etc, flexible pipe suitable to withstand upto 100 °C for hot and cold water, Anchor faster- 04 Nos of suitable size, 3 core PVC insulated, FRLS multistranded copper conductor cable and plug top of 15 Amp capacity complete in all respect complete all as specified & as directed by Engineer-in-charge. |
| 186 | Supply and fixing in replacement of carbon fiber heatingelement1000 watt , 240 volt, suitable for existing heat piller make gopi/belco or equvilentcomplete all unit all as directed by Eng-in-charge . |
| 187 | Supply and fixing slim panel type wall mounting heater, less burning oxygen, eco friendly convection tech,240 volt 1000 wattcomplete with nut bolt clamp and hanging unit etc all as directed by Eng-in-charge . |
| 188 | Material and labour for repair of central air heating plant complete fitted with AHU humididfier including repair/ replacment the following unserviceable/defective spares/parts including testing of the same after satisfactorily repaired :-(a) Finned strip heaters for fast heat transferas per existing capacity & sample =10 Nos(b) Repair of pump spray and nozzle blower =01 Nos(c) Replacement of defective ducting diffuser of suitable size asper existing required as per site(d) Re-winding of motor pump set of cap 1/2 HP =01 No(e) Thermostate as per the existing capacity =01 No(f) Micron filter 0.5mm of size 130x60cm =06 Nos |
| 189 | Material and labour for scraping out existing wornout disifigured paint from the super structure of Air heating plant with the help of sand/empry paper or blow lamp and re-painting the superstructure with two coat of anti-rust superior quality synthetic enamelled paint over one coat of red oxide primer complete all as specified and directed by Engr-in-charge |
| 190 | Material and labour for replace duct insulation with resin bonded fibre glass wool roll of density 24 kg/cum with factory laminated aluminium vapour barrier thickness of insulation as specified and including the following :(a) M&L for cleaing the duct surface (to be insulated) by scrapping carefully with wire brush etc to make the surface completely free of millscale dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage(b) M&L for applying rubber based adhesive CPRX compound (c) M&L for sealing of all longtitudinal joints and circular overlaps with and including aluminium foil tape 50mm wide, to make the insulation leakproof(d) M&L for securing the insulation with and including mechanically fastened nylon/steel straps of size 12mm/50mm at maximum intervals of 1.2mtr |
| 191 | Material and labour for complete servicing of 11 TR package AC plant complete in all respect including servicing of Indoor /Outdoor Unit with filters, copper fins and cleaning the entire unit complete all as specified & as directed by Engineer-in-charge. |
| 192 | Material and labour for repair of11 TRPackaged AC outdoor unitincluding repair/ replacment the following unserviceable/defective complete all as specified & as directed by Engineer-in-charge.(a) expansion valve |
| 193 | All as per item No 192 but Drier filter complete all as specified & as directed by Engineer-in-charge. |
| 194 | All as per item No 192 but Vacuum the compressor unit and testing of leakage and charging Gas of refrigment (R 407C) and testing complete all as specified & as directed by Engineer-in-charge. |
| 195 | All as per item No 192 but Belt A28 complete all as specified & as directed by Engineer-in-charge. |
| 196 | All as per item No 192 but OutdoorMotor with fan blade complete all as specified & as directed by Engineer-in-charge. |
| 197 | All as per item No 192 but Indoor Motors complete all as specified & as directed by Engineer-in-charge. |
| 198 | All as per item No 192 but Compressor 11 TR complete all as specified & as directed by Engineer-in-charge. |