Housing Urban and Rular Development Local Bodies Closing in 0 days TDR #44323896

Tender For Maintenance Of Completed Scheme Under Na-Ii (Horticulture Zone) Sh: Replacement Of Damaged Fittings , Damaged Cables , Lifting Of Pole Box& Replacement Of Damaged Poles Including Allied Accessories In Dda Park Ashoka Garden Ashok Vihar Phase-Iv

Issued by Local Bodies · vihar, Delhi
Tender Value
25.27 Lakhs
Estimated cost
Bid Submission
26 Jul 2024
0 days left
EMD
50544
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
vihar → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

maintenance of Completed Scheme under NA-II (Horticulture Zone) SH: Replacement of damaged Fittings , damaged cables , lifting of pole box& replacement of damaged poles including allied accessories in DDA Park Ashoka Garden Ashok Vihar Phase-IVof Hort. Division-2 under North Zone.

BOQ

Name of Work:- M/o Completed Scheme under NA-II (Horticulture Zone) SH: Replacement of damaged Fittings , damaged cables , lifting of pole box& replacement of damaged polesincluding allied accessories in DDA Park Ashoka Garden Ashok Vihar Phase-IVof Hort. Division-2 under North Zone.
Sl. No. Item Description
1Supplying, Fabrication and Replacement of 4 mtr. high pole made out of 65 mm dia NB, B class G.I pipe ISI marked duly welded with MS base plate of size 300 mm x 300 mm x 12 mm thick with suitable earth stud on base plate and V-Type Mounting arrangement made out of 80mm GI Pipe of 200 mm & 40 mm GI Pipe of minimum 300 mm length, making suitable size hole in pole at a height of 2.5 meter from base plate for cable entry/exit, painting & numbering of pole, making suitable hole in base plate for cable entry/exit into the pole and fixing the pole on the existing foundation with the existing nuts-bolts, washers etc. complete as required.
2Supplying, fabrication & Replacement of 6 mtr. high pole made out of 80 mm dia NB, B class G.I pipe ISI marked duly welded including with 4 nos. of supports withMS base plate of size 300 mm x 300 mm x 16 mm thick with suitable earth stud on base plate and with suitable side support providing and fixing 1000 mm dia ring type bracket made out of 48 mm dia nominal OD G.I pipe on top of the pole for mounting the 4 nos. of light fittings, making suitable size hole in the pole at a height of 2.5 meter from base plate for cable entry/exit for making connection to junction box, painting & numbering of pole, making suiatable hole in base plate for cable entry/exit into the pole and fixing the pole on foundation with the nuts-bolts etc. complete as required.
3Providing and laying in position 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)reinforced cement concrete foundation of size450 mm x 450 mm x 1200 mm deep (800 mm below ground level and 400 mm above ground level) including excavation of earth, refilling, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12mm. dia-1200mm long (approx) 8Nos, and reinforcement ring of cold twisted bar of 8mm dia -1400mm long (approx) -6 nos, (with suitable spacing) including centering & shuttering as required with providing, fixing and positioning of one set of foundation bolts comprising of 4 nos., 16 mm dia, 750 mm long J-Type MS bolts (Threaded portion shall be galvanized) along with 3 nos. GI nuts and 2 nos. GI washers etc. per bolt and 1 no. anchor plate (3mm thick) of suitable size and providing 63 mm.(O.D) DWC pipe ISI marked for cable entry & exit etc. complete as required.(Note:- Dismantling of existing foundation and disposing of the Malba should be done within the quoted rates by the agency.)
4Providing and laying in position 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)reinforced cement concrete foundation of size600 mm x 600 mm x 1200 mm deep (800 mm below ground level and 400 mm above ground level) including excavation of earth, refilling, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12mm. dia-1200mm long (approx) 8Nos, and reinforcement ring of cold twisted bar of 8mm dia -1600mm long (approx) -6 nos, (with suitable spacing) including centering & shuttering as required with providing, fixing and positioning of one set of foundation bolts comprising of 4 nos., 16 mm dia, 750 mm long J-Type MS bolts (Threaded portion shall be galvanized) along with 3 nos. GI nuts and 2 nos. GI washerers etc. per bolt and 1 no. ancor plate (3mm thick) of suitable size and providing 75 mm.(O.D) DWC pipe ISI marked for cable entry & exit etc. complete as required.
5Supplying, replacement, testing and commissioning of 60 W LED sFlood lightlight fitting (IP:66) with lens complete with pressure die cast aluminium housing with LEDs, driver, all accessories, providing suitable size ofprotection frame for fitting, making connection etc. as required. (Suitable mounting arrangement for fitting shall also be provided if required within the quoted rates).
6Supplying, replacement, testing and commissioning of 45 W LED streetlight fitting (IP:66) with lens complete with pressure die cast aluminium housing with LEDs, driver, all accessories, providing suitable size ofprotection frame for fitting, making connection etc. as required. (Suitable mounting arrangement for fitting shall also be provided if required within the quoted rates).
7Supply & replacement of pole connector box made out of Glass Reinforced Polyester Sheet Moulding Compound Conforming to IS:13410-1992 Grade S1 of outside dimensions 280 mm(H) x 170 mm(W)x 115 mm (D) (all the corners of the box should be round & not pointed ones) suitable to mount on 40/50/65/80 mm dia GI pole with the followingprovisions/accessories mounting in box complete as reqd.(i)2 nos. clamps made out of 19mm x 3 mm GI strip of suitable length for mounting box on the pole.(ii) Water tight front cover with 2 nos. stainless steel hinges & 1 no. screw for tightening.(iii)4 way, 220 V, 30 A, dough moulded connector (SMC with stainless steel inserts)(iv) 16 amp. Moulded SMC rewireable kit-kat---1 no.(v) Earthing bolt M6 x 20 mm
8Supplying & drawing following size FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required.a)3 x 1.5 sq. mm
9Supplying of following sizes of XLPE insulated PVC sheathed Al. cond. Armoured power cable of 1.1 KV grade including connection, testing etc. as required. a) 2C x 16 sq. mm
10Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required.a)Upto 35 sq. mm
11Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.a) Upto 35 sq. mm
12Dismantling of existing pole connector box & closing of existing hole and Supply & fixing/replacementof pole connector box made out of Glass Reinforced Polyester Sheet Moulding Compound Conforming to IS:13410-1992 Grade S1 of outside dimensions 280 mm(H) x 170 mm(W)x 115 mm (D) (all the corners of the box should be round & not pointed ones) suitable to mount on 40/50/65 mm dia GI pole with the followingprovisions/accessories mounting in box complete as reqd.(i)2 nos. clamps made out of 19mm x 3 mm GI strip of suitable length for mounting box on the pole.(ii) Water tight front cover with 2 nos. stainless steel hinges & 1 no. screw for tightening.(iii)4 way, 220 V, 30 A, dough moulded connector (SMC with stainless steel inserts)(iv) 16 amp. Moulded SMC rewireable kit-kat---1 no.(v) Suitable size hole at suitable location on rear wall for cable & wire entry.(vi) Earthing bolt M6 x 20 mm(vii) Making suitable size hole in the pole at height of 3 mtr. from bottom for incoming and outgoing the cable - 1 Job.(viii) Filling of existing hole in Pole.
13Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. i)2C x 16 sq.mm
14Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub main wiring/cable as required.
15Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required.
16Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required

AI Tender Summary

OUR REF NO 44323896
AUTHORITY Local Bodies
TENDER VALUE 25.27 Lakhs
LAST DATE 26-07-2024
Authority
Authority Name Delhi Development Authority
Work Description maintenance of Completed Scheme under NA-II (Horticulture Zone) SH: Replacement of damaged Fittings , damaged cables , lifting of pole box& replacement of damaged poles including allied accessories in DDA Park Ashoka Garden Ashok Vihar Phase-IVof Hort. Division-2 under North Zone.
Basic Detail
Tender No 13/EE/ELD-12/DDA/2024-25
Bidding Type Tender
Location
City vihar
State Delhi
Key Dates
Publish Date 20 Jul 2024
Submission Date 26 Jul 2024
Open Date 27 Jul 2024
Finance
Tender Value 25.27 Lakhs
Tender Fee Ref. Documents
EMD 50544
Exemption Available
Document List
bb4391f1-da36-418a-8093-151a564285b2.html
BOQ_859144.xls
NIT13.pdf
pwd07.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 20, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 26, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 27, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

bb4391f1-da36-418a-8093-151a564285b2.html

xls

BOQ_859144.xls

pdf

NIT13.pdf

pdf

pwd07.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders