| 1 | Foundation excavation in hard soil including levelling and dressing the bed and sides depositing muck within initial lead and lift etc. complete as per direction of Engg-in-Charge . |
| 2 | Supplying, filling in foundation and plinth with sand in 22.5 cm (9”)thicklayersincludingwateringandrammingwithcost, conveyance, royalties and taxes of sand with labour and T&P requiredfortheworketc.complete(Measurementwillbetaken on finished compacted section only). |
| 3 | C.C.( 1:3:6) in foundation and floors using 4cm (1½”) size HGCB metalwithalllabour,cessandT&Prequiredfortheworketc.completeinall respect. |
| 4 | Plaincementconcrete (1:2:4)using12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concreteinlayers,watering,curingetc.completeincluding cost, conveyance, royalties and excluding GST of all materials with labour,cess and T&P etc. required for the work complete. |
| 5 | R.C.C.workM-20grade using20mmand10mmsizeblack hard crusher broken granite chips including hoisting lowering layingandcentringshutteringandfinishingtheexposed surface smooth providing groves or beds wherever necessary includingcost,conveyance,royaltiesandexcludingGSTand costofallmaterialsandlabourwithT&Prequiredforthe worketc.completeinallrespectexcludingthecostofM.S. RodsorTorsteelandbindingwiresandlabourchargefor bending binding and tying grills as directed by the Engineer – in charge. |
| 6 | (a) Column base, frustum, plinth band |
| 7 | (b) Lintel |
| 8 | (c) Column and beam |
| 9 | (d) Sun shade, loft and Chajja |
| 10 | (e) Roof Slab |
| 11 | Supplying, fitting andplacinguncoatedHYSDbar reinforcement complete as per drawing and technical specification including cost, conveyance and excluding GST of allmaterialswithlabour, cessand T&Petc. requiredforthe work complete. |
| 12 | FlyAshbrickmasonryincementmortar(1:6)inPlinth& Foundation work using fly ash bricks of23cm x 11cm x 8cm sizehavingacrushingstrengthofnotlessthan75kg/cm2 withdimensionaltolerance±2%includingsplayscutting circularmouldingchamferingandcorbelling andsimilarsuch typeofworkswithallnecessaryprojectionswateringand curing including cost, conveyance, royalties and excluding GST of all materials with all labour, cess and T&P required for the work complete in all respect in all floors. |
| 13 | FlyAshbrickmasonryincementmortar(1:6)in Super strucutre work using fly ash bricks of23cm x 11cm x8cmsizehavingacrushingstrengthofnotlessthan100kg/cm2 to 149Kg/sqcm withdimensionaltolerance±2%includingsplays cutting circular moulding chamfering and corbelling and similarsuch type of works with all necessary projections watering and curing including cost, conveyance, royalties and excluding GST of all materials with all labour, cess and T&P required for thework complete in all respect in all floors. |
| 14 | 6mmthickcementplaster(1:4)toRCCsurfacesfinished smoothincludingcloseddeepchippingandslurrytreatment including watering and curing with cost, conveyance, royalties andexcludingGSTofallmaterialswithalllabourandT&P required for the work etc. complete in all respect. |
| 15 | 16mm(5/8”)thickcementplaster(1:6)finishedsmoothto inside rough surfaceof 9”/10” thick brick wallsafter rakingoutthejointsincludingwateringandcuringwithcostwithcost, conveyance, royalties and excluding GST of all materialswith all labour, T&P required for the work etc. complete. |
| 16 | 12mm(½”)thickcementplaster(1:6)finishedsmoothto outside smooth surface of brick walls after raking out the jointincluding watering and curing with cost, conveyance, royaltiesandexcludingGSTofallmaterialswithalllabourandT&Prequired for the work etc. complete in all respect. |
| 17 | Supplying, Fitting and fixing Vitrified tiles in Floors of size 600mm x 600 mm of approved make conforming to IS13755 laid on 25mm thickcementmortar[1:1] fillingjoinedwith whitecementofapprovedqualityincludingallmaterials, labour, excludingGST,T&Petc.requiredforthe work all complete as per direction ECI |
| 18 | Fixing of Vitrified tiles 60 cm x 60 cm (plain / ivory) series in dado, skirting and risers of steps on 12mm thick cement plaster in mortar (1:3) joined with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete including cost of precast tiles in ground floor. |
| 19 | Fixing Ceramic tiles in Floors, Treads on steps & landing on 25 mm thick bed of cementmortar[1:1]joinedwithneat cement slurry mixed with pigment to match the shade of the Tilesincludingrubbingandpolishing complete including rubbingandpolishingetc. completeincludingwateringand curing with cost, conveyance, royalties and excludingGST of all materials with all labour and T&P required for the work etc. complete in all respect. |
| 20 | Fixing Ceramic tiles in Dado, Skirting and rises of steps on 12 mm thick cementmortar [1:3] joinedwithneatcement slurrymixedwithpigmenttomatchtheshadeoftheTiles includingrubbingandpolishingcomplete includingrubbing and polishing etc. complete including watering and curing with cost, conveyance, royalties and excluding GST of all materials with all labour and T&P required for the work etc. complete in all respect. |
| 21 | Primingonecoattowallsurfacewithwaterboundcement primer including cost, conveyance,excluding GST of all materials, labour and T&P etc. complete |
| 22 | FinishinginsidewallswithDistemperofapprovedshadeon new work two coats to give an even shade including watering and curing with cost, conveyance, royalties and excluding GST of all materials with all labour and T&P required for the work etc. complete in all respect. |
| 23 | Finishing exterior walls with weather coat of approved shade two coats on new work to give an even shade including cost of paint. |
| 24 | Cost of PVC/FRP panel type (single shutter) frame doors including cost, conveyance,excluding GST of all materials, labour and T&P etc. completeSize:0.75x2.10m |
| 25 | Supplying, fitting and fixing of fabricated M.S Door& Window with grills and shutter /Ventilator etc made out of M.S. square bar / M.S. flats / M.S. angles /MSPlate as per approved drawing and design,includingcost,conveyance,taxesofall materials,requiredscrews,costofalllabour,T&Petc.as required for the work complete as per direction in all floors. |
| 26 | Primimg one coat with any approved red oxide primer over iron works including cost of primer. |
| 27 | Painting two coats with approved paint over the surface including cost of paint |
| 28 | FlyAshbrickmasonryincementmortar(1:4)inPlinth& Foundation work using fly ash bricks of23cm x 11cm x 8cm sizehavingacrushingstrengthofnotlessthan75kg/cm2 withdimensionaltolerance±2%includingsplayscutting circularmouldingchamferingandcorbelling andsimilarsuch typeofworkswithallnecessaryprojectionswateringand curing including cost, conveyance, royalties and excluding GST of all materials with all labour, cess and T&P required for the work complete in all respect in all floors. |
| 29 | 12mm(½”)thickcementplaster(1:4)finishedsmoothto outside smooth surface of brick walls after raking out the jointandexcludingGSTofallmaterialswithalllabourandT&P required for the work etc. complete in all respect. |
| 30 | Cementpunningincludingwateringandcuringwithcost, conveyance, royalties, and excluding GST of all materials with alllabourandT&Prequiredfortheworkcompleteinall respect. |
| 31 | Supply, fixing of RCC precas trings of 0.9 m dia, 0.3 m height, 0.050 m wall thickness in soak pit including cost of conveyance and excluding GST as per the direction of the engineer - in - charge. |
| 32 | 10 cm thick dry brick khoa backing in soakpitincluding cost, conveyance, excluding GST of all materials, labour and T&P etc. complete |
| 33 | PH&Sanitary Fittings |
| 34 | Supplying, fitting and fixing the following GI/PVC/CPVC/UPVC pipes with supply of required Nos. of GI fittings as per PH standard specification. |
| 35 | 25mm dia UPVC Pipe |
| 36 | 25mm dia UPVC Union |
| 37 | 25mm dia UPVC ASTM Ball Valve |
| 38 | 25mm dia UPVC ASTM Tank Nipple |
| 39 | 25mm dia UPVC Brass Male Threaded Adaptor |
| 40 | Supplying all materials, T&P and providing 500 ltrs capacity -Double layer IS-12701-1996 rotational moulded polyethylenecylindrical vertical water storageTank( Sintex/Supreme) including hoisting of PVC Sintex Tank carefully and placing in position by the help of scaffolding with connection of loading & delivery line and all required fittings such as socket, union, jam nut etc, staging all complete as per direction of the EIC. as per specification, all complete. |
| 41 | Internal water supply work : |
| 42 | Supplying all materials,labour and T&P for cutting grooves in pucca floor and walls for taking GI pipes and fittings/ PVC pipes and fittings and making good to the damages all complete as per specification. |
| 43 | Supplying, fitting and fixing the following GI/PVC/CPVC/UPVC pipes with supply of required Nos. of GI fittings as per PH standard specification |
| 44 | 20mm dia CPVC Pipe |
| 45 | Supplying, fitting & fixing the following PH fittings and fixtures of standard make & quality as per PH specification. |
| 46 | EWC P Trap with PVC Seat & cover lid |
| 47 | 10Ltrs. Capacity PVC L/L cistern with Connection pipe & all required fittings |
| 48 | 22\" x 16\" Wash hand basin with complete fittings |
| 49 | Standard pedestal for W.H. Basin |
| 50 | C.P. Single Towel Rail 600mm long |
| 51 | C.P.Towel Ring Square |
| 52 | Soap Dish Holder |
| 53 | 2 Way bib cock with wall flange |
| 54 | 15x600mm long PVC Connection Pipe |
| 55 | 15mm CP Extension piece |
| 56 | CP Flange |
| 57 | 5\" C.P. Grating |
| 58 | 600mm. long C.P. Glass shelf with glass |
| 59 | 24\"x18\" size bevelled edge plate glass mirror with hard board backing and CP brass dome headed mirror screw. |
| 60 | 15mm Angular Stop Cock with wall flange( big) |
| 61 | Hand Shower (Health Faucet) with 8mm dia 1m long flexible tube & wall hook. |
| 62 | CP PillarCock |
| 63 | Supplying fitting & fixing the following H.C.I./ P.V.C S.W.R pipe & fittings as per PH specification & direction of EIC. |
| 64 | 110mm dia PVC SWR PipetypeB |
| 65 | 110mm dia PVC SWR Door Bend |
| 66 | 110mm dia PVC SWR Plain Bend |
| 67 | 110mm dia PVC SWR P Trap |
| 68 | 110mm dia PVC SWR Gully Trap |
| 69 | 110mm dia PVC SWR Cowl |
| 70 | 110mm dia PVC SWR Clamp |
| 71 | 75mm dia PVCSWRPipeB |
| 72 | ELECTRICAL WORK ( INTERNAL ) |
| 73 | WIRING |
| 74 | Recessed wiring light point/fan point/exhaust fan point / Call bell point in 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of isi marked with 20 mm. dia non metallic PVC flexible conduct with 5 Amp,250V modular type switch ISI marked and sealing rose ISI marked mounted on modular box having front modular cover of suitable size, modular box with 1.5 sq.mm. FR PVC insulated single core multistrand cupper conductor as earth wire including all accessories and connection as per direction of engineer in charge. (Make of wire Finolex/ L&T/ Anchor/ Havels/ HPL/ VGUARD) |
| 75 | Group-A |
| 76 | Group-B |
| 77 | Group-C |
| 78 | Supply and fixing of 6Amp plug with 6Amp switch on existing board ( modular type ) |
| 79 | Supply and fixing of Modular metal box on surface or in recess with suitable size of modular cover in front including providing and fixing of 6Amp plug with 6Ampmodular switches connection . |
| 80 | Supply and fixing of Modular metal box on surface or in recess with suitable size of modular cover in front including providing and fixing of 6pin6Amp & 16 A socket outlet and 16Ampmodular switches connection . |
| 81 | Supply and fixing of Modularfan regulator |
| 82 | electronics step typeRegulator ( modular type ) |
| 83 | Supplying .and fixingof following sizes of modular boxes in recessed wiring includingcutting the wall and making good the same in case of recessed conduit as required( modularbox + cover + fixing + Labour cess ) |
| 84 | 2 modulee |
| 85 | 3 modulee |
| 86 | Recessed submain wiring alongwith earth wire with the following sizesof PVC insulated single core multistrend copper conductor of ISI marked conforming to IS-694/1990 in 20 mm dia non-metallic heavy duty flexible conduct 1.6mm in recessed PVC conduit as required . (Make of wire Finolex/ L&T/ Anchor/ Havels/ HPL/ VGUARD). |
| 87 | 2 x 2.5 sqmm + 1 x 1.5sqmm |
| 88 | supply and fixing of 5 Amp to 32 Amp rating 240/415 V B series miniature circuit breaker suitable for lightning and other loads for the following poles in the existing MCB DB ISI marked complete with connection testing and commissioning etc. as required. |
| 89 | single pole |
| 90 | supply and fixing of ICDP-Main SwitcISI marked complete with connection testing and commissioning etc. as required. |
| 91 | Mswitch |
| 92 | EARTHING |
| 93 | Supply and fixing earthing with GI earth pipe 3mtr long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having looking arrangement and watering pipe etc. with charcoal and salt as required. |
| 94 | standard earthing as per Govt. spcn |
| 95 | Providing and fixing 30mm x 6mm GIstrip |
| 96 | FITTING & FIXTURES( Internal Building ) |
| 97 | Supply,fixing of 18Watt LED t-5 tubelet light(make Havells,Philips,Crompton)complete with allcost including labour,T&p as per direction of EIC |
| 98 | Supply,fixing of 20Watt LED square surface mount with compact enclosure with fittings (make Havells,Philips,Crompton)complete with allcost including labour,T&p as per direction of EIC |
| 99 | Supply, Fixing of 15watt LED Bulbwith allfitting and connection |
| 100 | Supply & Fitting ofCeiling fan 1200mm sweep ac ISI Mark(Make Phillips/CG/VG/)ceiling fans-zestcomplete with allconnections& Fittings |