| 1 | Demolition of brick work built in cement mortarincluding all quoins arches etc |
| 2 | Demolition of cement conc in ground floor and pavings not exceeding 15 cm thick above or below ground level. |
| 3 | Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) cement concrete is reinforced (reinforcement cutas required to facilitate demolition) |
| 4 | Taking down cement or cement lime plaster incl raking out joints hacking for keys srubbing down with water etc |
| 5 | Taking down chowkats or frames with Shutters( without taking off the shutter from the frame ) of area n.exc 1.50 Sqm each and removing from site. |
| 6 | All as perItem No 5 above but area exc 1.50 Sqm but n.exc 4.00 Sqm |
| 7 | Taking shutter only of any desription of size exc 1 sqm and n.exc 2sqm |
| 8 | Ditto all as per item No 7 above but refixing in the same opening |
| 9 | M&L brick work , with sub class \"B\" bricks built in cement mortar 1:6 straight or curved on plan exc 6 mtr mean radius |
| 10 | Ditto all as per item No 09 above but except brick work complete all as specified. |
| 11 | M&L 15mm thick cement plastering in cement mortar (1:6) on other than fair faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified. |
| 12 | M&L for 15 mm thick cement plastering in cement mortar (1:4) on fair faces of brick work or concrete surfaces with using water proofing compound finished even & smooth without using extra cement complete all as specified. |
| 13 | M&l for 5 mm th rendering in cement mortar in 1:3 on ceiling |
| 14 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering to Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening conforming to GdeFe 290(Gde E-165) |
| 15 | S & F 1 mm thick Mild steel, plain, black sheet in wall cladding, steel gates and cup board with all locking arrangement and back support similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required |
| 16 | S&F 30mm thickflush shutter solid core constructionwith block board core and plywood face panels commercial face on both faces including both face is covered with decorative face veneer with lipping/frame including hydraulic door closerto match complete all as specified and as directed |
| 17 | M&L for 35mm th IInd class HW glazed /gauged shutters open rebatd and prepared to receive glass /gauge etc without sashbars edges of framing plain or chamferedr rounded fitted with cut and mitred beads for securing glass/gauge etc all as specified in SSR Part I section 8 clause 8.24 (a) complete all as specified and as directed |
| 18 | Supply & fixed factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat /Frame size 65x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. |
| 19 | Supply & fixed factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and including locking arranmgement andfixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. |
| 20 | S & F for Anodised aluminium frame Powder Coated (minimum thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 21 | S & F Anodised aluminium powder coated of any colour (Thickness or powder coating not less than 50 micron).window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws incl all accessories etc. complete all as specifiedetc. complete all as specified |
| 22 | S & F for Anodised aluminium powder coated of any colour (Thickness or powder coating not less than 50 micron). window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) incl all accessories completeallasspecified |
| 23 | Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin- charge. |
| 24 | S & F 5.5 mm thick glass sheet ordinary quality glazing fixing in aluminium frame black or transparent in square n.exc0 .5sqm in each pane all as specified and directed by Engineer-in Charge |
| 25 | S&F 12 mm size of mesh of wire netting of stainless steel wire 1.4mm dia fixed with tinned tacks of stainless steel wire staples all as specified and directed by Engineer-in Charge |
| 26 | M & L 25 mm thick Prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination,including magnetic catcher and all kitchen cabinet accessories andfixed with screws to timber frame work |
| 27 | S&F 300mm size mild steel sliding door bolt plate type stove enamelledblack with bright bolt not less than 12mm diaincl a minimum of six nut and bolts ,four on bolt plate and two on stapple plate complete all as specified |
| 28 | S&F steel locking bolts with mild steel electrogalvanised plate and bright bolt not less than 10mm dia 100mm size etc all as specified |
| 29 | S&F 150 mm size steel handle cast type polished brightsteel pressed handle oval typestoveall as specified and directed by Engineer-in Charge |
| 30 | S&F 100 mm size mild steel butt hinges medium weight |
| 31 | S&F floor door stopperaluminiumalloy body and tounge 140mm anodised with hard drawn steel spring etc |
| 32 | S&F 300mm size mild steel rat rail rod pattern spring including roller and roller plate complete |
| 33 | M&L Granite (of any type) work (table rubbed and polished) 20 mm thickin steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over screed or bedding layer in CM 1:4 all as specified and directed by Engineer-in Charge |
| 34 | M&L Non-skid coloured ceremic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles over15 mm th screed or bedding layer in CM 1:6 complete all as specified and directed by Engineer-in Charge. |
| 35 | M&L for glazedceramictiles coloured of size 450 mm x 350 mm x 7mm th on vertical surfaces such as in skirting, dado etc over 10 mm th backing coat in cm 1:4 complete all as specified |
| 36 | M&L 20-25 mm th machine cut kota stone slab flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing, over 20 mm th screed or bedding layer in CM 1:6 all as specified and directed by Engineer - in - Charge |
| 37 | All as per item No 36 above but as in skirting over 10mm th rendering in CM 1:4 complete all as specified |
| 38 | Form work to soffits of suspended slab such as roof slab n exc200mm thick (horizontal/sloping/vertical) with fair finished surfacecomplete all as specified |
| 39 | M & LTMT bars6mm to 8mm dia. cut to length bent to shape required including cranking, bendingand binding with and including ms wire (annealed) n. less than 0.9mm dia or securing with clips complete all as specified |
| 40 | Demolition of cement concrete is reinforced of any description and in any position not otherwise specifically provided for |
| 41 | M&L Reinforced cement concrete (nominal mix) TypeB0 1:2:4 (12.5mm graded aggregate) inslabs supported on walls, beams, columnsdeck slabs and in shelves, the like all as specified and directed by Engineer - in - Charge (Note:- Form work shall be measured and paid under respective item of BOQ). |
| 42 | M & L Reinforced cement concrete (nominal mix) TypeB0 1:2:4 (12.5mm graded aggregate) in Chajjas all as specified and directed by Engineer - in - Charge (Note:-Cost of from work shall be deemed to included in unit rate quoted). |
| 43 | S&F in repair vitreous china squatting pan ‘Orissa patten’ size 580x440mm white with intergral foot rest (excluding flushing cistern and flush pipe)with \"P\" or \"S\" trap including water connection to trap and flushing pipe, flushing cistern etc incl lime concrete bedding and PCC 1:2:4 for making good the floor fixed in repair complete all as specified |
| 44 | S & F in repair PVC 10 ltrs syphonic action type flushing cistern, low level with inlet, ball valve, float and handle including brackets, flush pipe of PVC 32mm bore, connection to WC pan & PVC connection 15mm size with PTMT nuts of length 300mm complete all as specified . |
| 45 | S& F vitrious china wash hand basin flat back550X400mmincl fixing bracket, pvc waste coupling and waste pipe,cp pillar cock swan neck etc all as specified and directed by engineer-in-charge. |
| 46 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers etc all as specified and directed by engineer-in-charge |
| 47 | S&F in replacement 20 mm dia harrison rails mild steel with decorative finish , with fixing brackets , stops, rollers complete all as specified and as directed (two brackets per 1.5 M length and 08 Nos roller per 1.RM) |
| 48 | Dismantling brick tile or terracing tile single layer on roof |
| 49 | Demolition of mud in roofs ,any thickness incl plastering and leeping (weather full thickness removed or part there of) |
| 50 | Demolition of cement Concrete of any description and in any position not otherwise specifically provided for |
| 51 | M/L for PCC 1:5:10 type E2 with using 40 mm graded stone aggrgate as infilling for sunken floorand like works |
| 52 | Supply only Integral waterproofing compound |
| 53 | Applying evenly a tack coat of industrial bitumen 85/25 at the rate of1.2 kg per sq.m including cleaning surfaces |
| 54 | APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) laid on primed surface by torch application complete all as specified |
| 55 | M&L for 75 mmaverage consolidated thickness PCC 1:2:4 type B1with using 20mm graded stone aggregate as in padding on flat roofs etc all as specified and directed. |
| 56 | M/L 40mm thick brick tiles laid on mud mortar and joints grouted flush incement mortar (1:3) mixed with 5% of crude oil by weight of cementand pointed flush in CM 1:3 |
| 57 | All as per item 56 above but except tiles |
| 58 | M/L Providing, cement concrete type B-0 1:2:4 (12.5 mm graded aggregate ), asin roof kerbs or mud stops, rounded or chamfered on edges parapets copings, bed plates, etc |
| 59 | Cutting groovesof size 75mm wide and 65mm deep in brick parapet wall for inserting APP membrane and making good the disturbed portion in CM (1:3) etc all as specified |
| 60 | Dismantling water tanks of any description exc 250 and n.exc 500 ltr capacity |
| 61 | S&F Rotational moulded polythene water storage tanks double layer (cylinder each vertical with closed top) of capacity 500 Itrs, hoisted and fixed in position including pvc float valve 20mm size,specified in SSR Pt-1 Make : Sintex / Frontier /Polycon |
| 62 | Taking up/ down GI tubing and connections with all fittings 15 mm bore |
| 63 | Ditto all as per item No 62above but 20mm bore |
| 64 | S&F 15 mmdia GI tubingand connections fixed to wall or ceiling,laid in floor etc |
| 65 | ditto all as per item 64 above but fixing only |
| 66 | S&F 20 mmdia GI tubingand connections fixed to wall or ceiling,laid in floor etc |
| 67 | ditto all as per item 66 above but fixing only |
| 68 | S&F in repairCP shower rose 15mm sizefixed to iron pipe |
| 69 | S&F pvc connection 15mm size with PTMT nuts of length 450mm |
| 70 | S&F in repair 15mm CP Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed |
| 71 | S&F in repair 15mm size brass stop valveswith crutch or butterfly handles high pressure screwed both endsfor iron pipe |
| 72 | Ditto all as per item No 71 above but fancy type, chromium plated with long shank and cup (concealed type) |
| 73 | S&F in repair 20mm size stop valves PTMT high pressure screwed for iron pipe |
| 74 | S&F in repair towel rail 600mm long of PTMT incl cp brass srews etc |
| 75 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 76 | M&L preparing new surfaces ofwalls and applying two coats of oil bound distemper over a coat of alkali primer etc all as specified |
| 77 | M&L preparing old surfaces ofwalls and applying two coats of oil bound distemper over a coat of primercomplete all as specified |
| 78 | M&L preparing surfaces of newwalls and applying two coated of cement base paint over and acoat of alkali primer |
| 79 | M&L preparing old surfaces ofwalls of walls and applying two caots of cement base paint etcall as specified |
| 80 | M&L for three coats of white wash onon ceiling on newly plastered surfaces |
| 81 | M&L for two coats of white wash on ceiling on oldplastered surfaces |
| 82 | M&L for two coats synthetic enamel paint on new wooden surface over 10 cm width or girth over a coat pink primer |
| 83 | Ditto all as per item 82 above but one coat on old treated surface |
| 84 | M&L for two coats of synthetic enamel paint on new steel surface over 10cm width or girth over a coat red oxide primerv etc all as specified |
| 85 | Ditto all as per item 84 above but one coat on old treated surface etc all as specified |
| 86 | M&L PCC 25mmth 1:2:4 type B-0using 12.5 mm graded stone agg as in levelling course. |
| 87 | M&L for 75 mm thPCC 1:3:6type C2 as in plinth protectionwith using 40mm graded stone aggregate etc all as specified. |
| 88 | S&F in repair PVC SWR pipe 110 mm dia single socketed in any length with rubber ring joints fixed to walls etc all as specified |
| 89 | Ditto all as per item No 88 above but laid in trenches |
| 90 | S&F in repair PVC SWR pipe 75 mm dia single socketed in any length with rubber ring joints fixed to walls etc all as specified |
| 91 | Ditto all as per item No 90above but laid in trenches |
| 92 | S&F in repair 75mm size PVC (SWR) floor trap plain with grating incl to jointing with waste pipe with adhessive etc all as specified |
| 93 | S&F 110 mm dia PVC SWR type bends any radius complete all as specified |
| 94 | Ditto all as per item No 93 above but 75mm dia etc all as specified |
| 95 | S&f 100 mm dia stack clampmade out of25x4mmFlat iron etc all as specified |
| 96 | S&f 75mm dia stack clampmade out of25x4mmFlat iron etc all as specified |
| 97 | S&F sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, incl waste coupling and waste pipe etc all as specified |
| 98 | Taking down carefully aluminimum point wiring on TW Batten/in conduit / with conduit (light/Fan/socket or power) complete and making good the disturbed surface of wall/ceiling etc including taking down fitting such as switches, ceiling roses, pendants, Regulators,sockets, light fitting etc and removing material from site complete all as directed. |
| 99 | M&L for point wiring with 1.5 Sqmm, PVC insulated, unsheathed, multi stranded copper conductor single core FRLSH cable, IS-694 marked, drawn through and including non metallic rigid PVC concealed conduit 20mm dia or higher by cutting of walls (bricks & stone) and making good disturbed surface of wall in CM 1:3 (except on ceiling for fan point only , surface conduit will be used in lieu of concealed PVC conduit ) complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc./ fittings ISI marked and sunk type pressed steel anodised terminal box 1.2 mm thick with bakelite laminated sheet top cover 3 mm thick( Make - Hylem/Anchor)ISI Marked, brass screws and cup washers including 1.5 Sqmm multi stranded copper conductor PVC insulated green in colour as continous earth conductor connected to common earth and earth dolly with all accessories complete all as specified and directed for |
| 100 | All as per ser item 99 above but for 3 pin socket out let 5 Amps on same board. |
| 101 | All as per ser item 99 above but for 3 pin socket out let 5 Amps on independent board. |
| 102 | All as per srl item No 99 above but for 3 pin socket outlet 15 Amps with 2.5 Sqm stranded copper conductor PVC unsheathed cable independent including FRLSHPVC cable copper conductor 2.5Sqmm with green insulator as earth wire with cast iron/pressed steel terminal box all as specified. |
| 103 | All asper item No 99 above but one light point controoled by two way switches |
| 104 | Supply and fixing switch piano flush type 5 Amp single pole one way complete allas specified and as directed. |
| 105 | Supply and fixing switch piano flush type 15Amp flush type single pole one way complete all as specified and as diirected. |
| 106 | Supply and fixing switch piano 5 Amps flush type single pole two way complete all as specified and as directed. |
| 107 | Supply and fixing socket outlet 5 Pin 5 Amps flush type multi purposecomplete all as specified and as directed.Make Anchor/SSK/Leader. |
| 108 | Supply and fixing socket outlet multi purpose 2 in one, 6 pin 16 Amps flush . |
| 109 | Supply and fittingcall bell single phase 240 volt complete all as specifiedand asdirected. |
| 110 | Supply and fitting bell push flush type 5 amps complete all as specifiedand as directed. |
| 111 | Supply and fixing ceiling rose surface bakelite 65 x 50mm three treminal complete. |
| 112 | Supply and fixing lamps holder ,PVC/Polycarbonate type with cord grip cap each suitable for pendant fittings incl 10 watt Led lamp complete all as specified and as directed. |
| 113 | Supply and fixing fan regulator electronic step type and making connection complete all as specified and as directed. |
| 114 | Supply and fixing LED light fitting 1x20W,220V, AC decorative box type with driver, holder including 20/22 WattLED tubelight rod connectingup with three core flexible copper conductor cable of suitbale size from ceiling rose complete all as specified and as directed. |
| 115 | S&F LED mirror light fitting 1x 10 Watt sleek polycarbonate channel with white acrylic cover complete with all accessories pre-wired and including connecting flexible copper conductor cable with suitable size. |
| 116 | Supply and fixing LED light fitting 1x9W/ 1x10W bulk head luminaries including LED light driver holder connection up with three core flexible coper conductor cable of suitable size complete all as specified and as directed. |
| 117 | S&F of MCB distribution board single pole & neutral with 200 Amps rated bus bar,double door IP-43 DB\"s , made outof sheet steel enclosure, recessed type, factory made powder coated 8 way, 240 volts suitable for housing MCB\"s including blanking platecomplete all as specified and directed.Note: MCB DB and MCB SP/SPN will be of same make. |
| 118 | S&F of MCB distribution board TPN 4 way, 415 volts, double door, with 200 Amps rated bus bar, neutral bar with shrouds, earth bar,IP-43 , made outof sheet steel enclosure, recessed type, factory made powder coated suitable for housing MCBs as incomer andoutgoing including blanking plate complete all as specified and directed by Engr-in-Charge. Note: MCB DB and MCB SP/SPN will be of same make. |
| 119 | Supply and fixing amps rating 240V 10KA \"C\" curve minature circuit breaker (MCB) SPN 32 Amps complete all as specified and as directed. |
| 120 | Supply and fixing amp rating 240V,10KA \"C\" curve miniature circuit breaker (MCB) SP 6 to 32 amps complete all as specifiedand asdirected. |
| 121 | Supply and fixing 415V,10KA \"C\" curve miniature circuit breaker (MCB) of capacity 63 Amps TPN complete all as specifiedand as directed. |
| 122 | supply and fixing ofsingle pole and neutral enclosure with a two pin and earth plug and socket complete with one single MCB 20Amp 240 V |
| 123 | M&L for wiring with two runs of single 6 sqmm FRLSH PVC insulated unsheated multistranded 1100 vols grade with copper conductor drawn through and including in PVCconduit medium grade ISI marked and its accessories including one runof single core 6 sqmm FRLSH PVCinsulated unsheated multistranded 1100 volts grade with copper conductor cable as earth contuinity conductor along with the wiring and connected from DB to DB /main board complete all as specified and as directed. Make of wire- Havells/Polycab/Anchor/Finolex. Note:-Three items of 6 Sqmm FRLSH PVC insulated unsheated multistrand cable and are run of PVC conduct shall be measured as one running meter. |
| 124 | Material and labour for painting with one coat of synthetic enamel paint (Tint of paint as per existing) with spraying machine,writing MES No including preparation of surface , sweep 1200mm of ceiling fan complete all as specified and directed. |
| 125 | Supply and fix Exhaust Fans AC single phase 230/240 volts of size 300 mm sweep metal bodywith louver shutter including making holes for fixing of fan and making good the distrubed surface connecting with three core flexible copper wire from ceiling rose to connector of fan complete all as specified and directed. |
| 126 | S&F of ventilatiion fan250 mm sweep PVC body with louver shutter suitable for 230 volts, single phase 50 hz Ac supply , connecting with three core flexible copper cable including making hole for fixing of fan and making good the distrubed surface of wallcomplete all as specified and directed. |
| 127 | Supply and fixing storage type electric Water heater ( Geyser) single phase 230 volts, stainless steel tank, vertical type oc capacity 25 Ltr, BEE 5 star rated connecting inlet/outlet/vent pipes, electric/earth connections , mounting bolts, nutsand carrying out testing for proper functioning including wiriting MES No with black enemel paint complete all as specified and directed. |
| 128 | Material and labour for replacment of earthing with galvanized iron earth plate electrode 600mmX600mm,6mm thick buried directly in ground verticvally in a earth pit not less than 2.25mtrbelow normal ground level with top edge of the plate not less than 1.5mtr below normal ground level connected to GI earth wire 4 mm dia by means of GI bolts , nuts, check nuts and washers ( earth plate covered with alternate layers of charcoals dust and common salt 15cm thick), GI earth wire protected by GI pipe light grade 15mm dia upto switch borad and connected to main switch board including provision of GI pipe 20mm dia light grade watering pipe with funnel and wiremesh, all as shown in electrical plate No. 3 of SSR Part-1 , including PCC chamber(1:3:6) using 20mm graded stone aggregate and CI cover and frame including all necessary excavation and earth work and taking out old earthingcomplete all as specified and directed |
| 129 | Supply ,laying and testing cable XLPE insulated ,screened ,PVC bedded ,galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium condutor of size 25 sq mm 4 core (Note:- Excavation in earth work, returning filling in removal, sandand cable covers shall be measured and paid under respective items of BOQ). |
| 130 | Supply & fix GI pipe light grade of dia 40 mm laying in road and along with poles for cable protection complete all as directed by Engr-in-Charge. |
| 131 | Excavation in trenches in Soft/disntegrated not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of GI pipe etc or soil for shaft, walls, cesspts, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in Soft/loose of soil complete all as specified & directed by Engr-in-Charge. |
| 132 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soft/loose soil, all as specified & directed by Engr-in-Charge. |
| 133 | Removing excavated soil to a distance not exceeding 50 m and depositingwhere directed at a level not exceeding 1.5 mabove the starting point soft /loose soil all as directedby Engr-in-Charge. |
| 134 | Material and labour for Sand filling under floors in foundations including watering and consolidation.aii as specified and directed. |
| 135 | Supply and fix common burnt clay building brick Sub class B designation 75 all as specified and directed. |