Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #44305935

Tender For Supply Installation And Commissioning Of Water Testing Equipments Phe Lab Rohtak Under Jurisdiction Of Phe Divn.No-2 Rohtak Distt. Rohtak`

Issued by Government Departments · rohtak, Haryana
Tender Value
8.86 Lakhs
Estimated cost
Bid Submission
29 Jul 2024
0 days left
EMD
17720
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
rohtak → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Supply installation and commissioning of water testing equipments PHE Lab Rohtak under Jurisdiction of PHE Divn.No-2 Rohtak Distt. Rohtak`-- 1 Autoclave Vertical • Size-78 ltr/ 98 ltr • It should have double wall construction with boiler made of Stainless Steel 16-gauge sheet. Outer shell is also made of Stainless-Steel Sheet/ Mild Steel. Boiler and outer shell are provided with air insulation. Lid is made of Stainless-Steel Sheet and tightened all-round by radial locking. Joint less gaskets are made of Neoprene rubber. These sterilizers are hydraulically tested up to 40 PSI. • Should have fully automatic PID Controller • Automatic timer electronic 999 mtsSterilizers are fitted with water level arrangementto indicate water position inside the boiler. Pressure gauge, Air/Steam release cock two safety valve are also provided. The autoclave is fittedwith indfoss pizzostat and can be set between 10 to 20 PSI. • Immersion type heating element heats the water and steam to desired temp. and pressure are attained. We have provided all autoclaves to cutoff automatically when the autoclave is dry. Supplied complete with S.S. basket, cord and plug to work on 220 Volts 50 cycles A.C. supply • Traceability calibration certificate of controller should be provided • Instrument should be calibrated from NABL calibration laboratory. • Includes AMC for 5 years Make Popular, NST, Ambassador 2 Bacteriologic al incubatorInner Size: 18` x 18` x 24`, Rating Watts 750, No. ofShelves 3, capacity 120Ltrs Construction: Doublewalled construction outer body made of Mild Steelpowder coated, and Inner Body made of Stainless-SteelInsulation: Glass wool insulation between two walls.Temp range: room temperature to 60°C. Accuracy: plus /- 0.5 °C. Temp controlled by: Controlled by PIDMicro process controller with dual display. Selves:With G.I. wire Mesh selves Door: 2 door inner acrylicdoor to view sample and outer metal door. with aircirculation motor with blower for uniformtemperature throughout chamber. Heater: specialNichrome heater designed for long life and saving of power consumption 3 Colour Comparator for colour,Applicable Standard ASTM D1209 ISO 6271,Colour Type Transparent,Portability: PortableRange-Visual Colour Grading of PlatinumCobalt/Hazen/APHA Colour (Range 0 - 250 mg),Disc-NSB Hazen scale disc Range: -70 - 250 mg Pt/l,CAA Hazen scale disc Range: -0-30 mg Pt/l,CAB Hazen scale disc Range: -30-70 mg Pt/l,(The bidder should provide Colour Glass disc),Nessleriser,1 X Pair Nessleriser Daylight 2000 plus ,1 X Pair Stand for Nessleriser Unit,1 X Pair 2150 Nessleriser body,1 X Pair 2250 Nessleriser body,1 X Pair of Nessler cylinder AF306P,1 X Pair of Nessler cylinders 250mm,DB420,Certification,The company should have ISO Certification for,manufacture Water testing Instruments (NST,Ambassador,OpticsTechnology) 4 Digital BuretteTechnical Specifications for Bottle top burette:1. The bottle top burette should have motorcontrolled piston movement.,2. There will be different speed modesa. Fast,b. Medium,c. Slow to control dispensing speeds and to facilitate,accurate titrations.3. Bottle top burette should be able to dispense adroplet as small as 0.01 ml to ensure highly accurate end point. 4. It will have re-circulation mode that allows quickpurging without loss of reagent. to provide ease ofuse and save time, the burette should provide onetouch filling operation and refilling should be donewithout change in on-screen reading.5. Capacity: 50 ml 6. Increment: 0.01 ml 7. Systematic Error: Precise titration with the error limits of Class A: = 0.1% at nominal volume 8. Random Error: =0.02% at nominal volume(Microlit,Sartorius,Thermo FisherScientific,Brand, Borosil) 5 Multi-meterwith pH,Conductivity and DOAutomatic Buffer Recognition: Yes,Backlight: Yes,Barometric Pressure Measurement: Automatic,compensation of DO when using an LDO or LBOD,probe,Calibration: Demal (1D/ 0.1D/ 0.01D).,Molar (0.1M/ 0.01M/0.001M),NaCl (0.05%: 25µS/cm: 1000µS/cm: 18mS/cm)Standard sea water,User defined Calibration Intervals/Alerts/Reminder:Off, selectable from 2 hours to 7 days,Communication: Integrated USB type A (for USB 2.0 flash memory device, printer, keyboard) and Integrated USB type B (for PC) Compliance Certifications: CE. WEEE (Certifications are applicable only for European Union and USA)Conductivity measurement: Yes Conductivity measurement: Temperature correction:None: Linear: NaCl Non-Linear Natural Water. Conductivity Measurement Range: 0.01 µS/cm -200.0 mS/cm Conductivity resolution: 0.01 µS/cm - 0.1 mS/cm upon selected measuring range Contents: Meter Only,Custom Calibration Standards: Yes ,Data Export: Download via USB connection to PC or,flash memory device. Automatically transfer entire ,data log or as readings are taken., Data Memory: 500 records/FIFOData Storage: Automatic, GLP ISO compliant reading data stored with calibration details. Dimensions: 859 x 175 x 235 mm,Display: Detailed mode/Large mode,Display Type: 440 x 160-pixel LCD with backlight,illumination,DO Measurement Range: 0.1 - 20.0 mg/L (ppm) 1 -200% saturation,DO Resolution: 0.1,DO sensor calibration: • 100% (water-saturated air,(100%) calibration,• 100% with 0 (water-saturated air (100%) calibration with 0 point,• mg/L (calibration with a specified dissolved oxygen,concentration (mg/L) solution),• mg/L with 0 (calibration with a specified dissolved,oxygen concentration (mg/L) solution with 0 point)• Factory (calibration with the default LDO calibration) ,Electrode stand: Optional,GLP Features: Date: Time: Sample ID: Operator ID,Instrument: Bench,IP Rating: IP54 (Resistant to spray of water: Dustproof),ISE Direct Measurement Range: Yes,ISE Electrode Calibration: 2 - 5 points,Kit (Yes/ No): No,Lock Function: Continuous / Auto-stabilization (`pressto read`) / At Interval,Measurement method: Probe specific programmedmethod settings,mV Measurement at Stable Reading: Yes,mV Measurement Range: -1500 - 1500 mV,mV Resolution: 0.1 mV,Needed Cable Length: 2m or more,Operating Error Messages: Clear text error messages,displayed,Operating Humidity: 90 % relative humidity (noncondensing),Operating Interface: Soft Touch Keypad,Operating Temperature: 0 -plus 60 °C (32 - 140 °F),ORP Electrode Calibration: Predefined ORP standards(including Zobell`s solution),Parameter: pH/ Oxydo Reduction Potential (ORP)Conductivity/Total Dissolved Solid,,(TDS)/Salinity/Resistivity,Dissolved Oxygen (DO)Biochemical Oxygen Demand (BOD),Ion Selective Electrode (ISE): Ammonia, Ammonium,Chloride, Fluoride, Nitrate, Sodium,PC Data Transfer Software: HQd Series Meter DataTransfer Utility,pH Buffer Sets: Color-coded: 4.01, 7.00, 10.01 pH:,IUPAC: 1.679, 4.005, 7.000, 10.012, 12.45 pH DIN: 1.09, 4.65, 9.23 pH User-defined custom buffer sets,pH Electrode calibration: 1 - 3 Calibration points,Calibration summary data logged and displayed,pH Measurement Range: 0 - 14 pH,pH Resolution: Selectable:0.001/0.01/0.1 pH,Printer: Yes, Optional,Probes included: DO, pH and conductivity/TDS,Resistivity Measurement: 2.5 ?.cm - 49 M?.cm,Resistivity Resolution: 0.1,Salinity Measurement Range: 0 - 42 (ppt) (‰),Salinity Resolution: 0.01 (ppt) (‰),Simultaneous measurements: Yes,TDS Measurement Range: 0.00 mg/L - 50.0 g/L asNaCl,TDS Resolution: 0.01 mg/L - 0.1 g/L upon measuring range,Temperature Compensation: Automatic Temperature compensation for pH,Temperature Measurement: °C or °F,Temperature Range: -10°C - 110 °C,Temperature Resolution: 0.1Eutech,ThermoScientificOrion, WTW,Hach,Metrohm (with 5 years AMC) 6 Pipette Controller Technical Specifications: It will be battery operated electronic pipette filling device and will have Ergonomic design and robust.The pipette must extend smooth operation. The device must have designed to be used for most of the plastic and glass pipettes having volume from 0.1-100 ml. The device must be autoclavable.It will be Light in weight so it can be used forcontinuous operation without fatigue and enablesingle handed operation with minimum efforts. It willhave Dual dispensing with a single knob: Theinstrument will have different modes for dropwise andslow dispensing for fast dispensing). The device willhave continuous pump speed adjustment duringliquid handling operations.It will have replaceable PTFE hydrophobic membranefilter (0.2microns) to prevents aerosol contaminationand accidental liquid entry. Other Technical specifications:Fit: Pipette made of Glass or plasticSize: Pipette of volume size 0.1 ml to 100 mlBattery: Li-On or Ni-Cd batteries,Battery charger: Compatible with both 220V and 110V,Battery indication: Low battery and charging ,indication Operation: Minimum 6 hr continuous operation,Autoclaving Parameters: Autoclavable at 121 °C and15 psi for a duration of 10-15 minutes.Warranty: 2 yearsMicrolit,Sartorius,Thermo FisherScientific,Brand, Glassco,Borosil 7 Turbidity meter(Benchtop)/ (Portable)Range: 0-4000 NTU: Certification: CE, FCC, EC, EN, UL STD,Communication: RS 232, USB via adapter,Compliance: ISO,Data Log: 1000 total logs, includes reading log,verification log and calibration log, Date Time, User ,Display: LCD graphic, backlit, menu controlled,Interface: RS 232, USB via adapter, external printer,barcode scanner, PC ,Light source: Light-emitting diode (IR LED)/ TungstenFilament Lamp,Measurement method: Nephelometric,Operating temperature range: 0 - 50 °C,Power requirements (Voltage): 100 - 240 VAC with Lab station, ,Battery Operated 4 x 1.5 V, type AA for,approx. 3,000 measurements Resolution: 0.001 NTU: Repeatability ±1% of reading or 0.01 NTU whichever is greaterAccuracy: ± 2% of reading plus 0.01 NTU from 0 -1000 NTU, ±5% of reading from 1000 - 4000 NTU or better ,Reading Modes: Single, Intelligent Reproducibility and Plausibility Check (IRPC) procedure ,Regulatory: Meets ISO 7027, DIN EN 27027 Response time: (15 seconds 28x60 mm (1.10x2.36 in.), 20 ml sample volume Calibration Point Automatic 3-point calibration Weight approx. 0.6 kg (without batteries),Dimension 236 x 86 x 117 mm,Source Lamp: LED Stabilization time: Immediately,Storage conditions: -20 to 65 °CUnits: FNU and NTU Relative Humidity Yearly mean: ( 75 %: 30 days/year:95 %: Other days: 85 %, Type of Protection: IP 67(with 5 years AMC)

BOQ

Name of Work: Rohtak No.2 WQMSP(2023-2024) (01.04.2023) - (31.03.2024) `Supply installation and commissioning of water testing equipments PHE Lab Rohtak under Jurisdiction of PHE Divn.No-2 Rohtak Distt. Rohtak`
Sl. No. Item Description
1Autoclave Vertical • Size-78 ltr/ 98 ltr • It should have double wall construction with boiler made of Stainless Steel 16-gauge sheet. Outer shell is also made of Stainless-Steel Sheet/ Mild Steel. Boiler and outer shell are provided with air insulation. Lid is made of Stainless-Steel Sheet and tightened all-round by radial locking. Joint less gaskets are made of Neoprene rubber. These sterilizers are hydraulically tested up to 40 PSI. • Should have fully automatic PID Controller • Automatic timer electronic 999 mtsSterilizers are fitted with water level arrangementto indicate water position inside the boiler. Pressure gauge, Air/Steam release cock two safety valve are also provided. The autoclave is fittedwith indfoss pizzostat and can be set between 10 to 20 PSI. • Immersion type heating element heats the water and steam to desired temp. and pressure are attained. We have provided all autoclaves to cutoff automatically when the autoclave is dry. Supplied complete with S.S. basket, cord and plug to work on 220 Volts 50 cycles A.C. supply • Traceability calibration certificate of controller should be provided • Instrument should be calibrated from NABL calibration laboratory. • Includes AMC for 5 years Make Popular, NST, Ambassador
2Bacteriologic al incubatorInner Size: 18` x 18` x 24`, Rating Watts 750, No. ofShelves 3, capacity 120Ltrs Construction: Doublewalled construction outer body made of Mild Steelpowder coated, and Inner Body made of Stainless-SteelInsulation: Glass wool insulation between two walls.Temp range: room temperature to 60°C. Accuracy: plus /- 0.5 °C. Temp controlled by: Controlled by PIDMicro process controller with dual display. Selves:With G.I. wire Mesh selves Door: 2 door inner acrylicdoor to view sample and outer metal door. with aircirculation motor with blower for uniformtemperature throughout chamber. Heater: specialNichrome heater designed for long life and saving of power consumption
3Colour Comparator for colour,Applicable Standard ASTM D1209 ISO 6271,Colour Type Transparent,Portability: PortableRange-Visual Colour Grading of PlatinumCobalt/Hazen/APHA Colour (Range 0 - 250 mg),Disc-NSB Hazen scale disc Range: -70 - 250 mg Pt/l,CAA Hazen scale disc Range: -0-30 mg Pt/l,CAB Hazen scale disc Range: -30-70 mg Pt/l,(The bidder should provide Colour Glass disc),Nessleriser,1 X Pair Nessleriser Daylight 2000 plus ,1 X Pair Stand for Nessleriser Unit,1 X Pair 2150 Nessleriser body,1 X Pair 2250 Nessleriser body,1 X Pair of Nessler cylinder AF306P,1 X Pair of Nessler cylinders 250mm,DB420,Certification,The company should have ISO Certification for,manufacture Water testing Instruments (NST,Ambassador,OpticsTechnology)
4Digital BuretteTechnical Specifications for Bottle top burette:1. The bottle top burette should have motorcontrolled piston movement.,2. There will be different speed modesa. Fast,b. Medium,c. Slow to control dispensing speeds and to facilitate,accurate titrations.3. Bottle top burette should be able to dispense adroplet as small as 0.01 ml to ensure highly accurate end point. 4. It will have re-circulation mode that allows quickpurging without loss of reagent. to provide ease ofuse and save time, the burette should provide onetouch filling operation and refilling should be donewithout change in on-screen reading.5. Capacity: 50 ml 6. Increment: 0.01 ml 7. Systematic Error: Precise titration with the error limits of Class A: = 0.1% at nominal volume 8. Random Error: =0.02% at nominal volume(Microlit,Sartorius,Thermo FisherScientific,Brand, Borosil)
5Multi-meterwith pH,Conductivity and DOAutomatic Buffer Recognition: Yes,Backlight: Yes,Barometric Pressure Measurement: Automatic,compensation of DO when using an LDO or LBOD,probe,Calibration: Demal (1D/ 0.1D/ 0.01D).,Molar (0.1M/ 0.01M/0.001M),NaCl (0.05%: 25µS/cm: 1000µS/cm: 18mS/cm)Standard sea water,User defined Calibration Intervals/Alerts/Reminder:Off, selectable from 2 hours to 7 days,Communication: Integrated USB type A (for USB 2.0 flash memory device, printer, keyboard) and Integrated USB type B (for PC) Compliance Certifications: CE. WEEE (Certifications are applicable only for European Union and USA)Conductivity measurement: Yes Conductivity measurement: Temperature correction:None: Linear: NaCl Non-Linear Natural Water. Conductivity Measurement Range: 0.01 µS/cm -200.0 mS/cm Conductivity resolution: 0.01 µS/cm - 0.1 mS/cm upon selected measuring range Contents: Meter Only,Custom Calibration Standards: Yes ,Data Export: Download via USB connection to PC or,flash memory device. Automatically transfer entire ,data log or as readings are taken., Data Memory: 500 records/FIFOData Storage: Automatic, GLP ISO compliant reading data stored with calibration details. Dimensions: 859 x 175 x 235 mm,Display: Detailed mode/Large mode,Display Type: 440 x 160-pixel LCD with backlight,illumination,DO Measurement Range: 0.1 - 20.0 mg/L (ppm) 1 -200% saturation,DO Resolution: 0.1,DO sensor calibration: • 100% (water-saturated air,(100%) calibration,• 100% with 0 (water-saturated air (100%) calibration with 0 point,• mg/L (calibration with a specified dissolved oxygen,concentration (mg/L) solution),• mg/L with 0 (calibration with a specified dissolved,oxygen concentration (mg/L) solution with 0 point)• Factory (calibration with the default LDO calibration) ,Electrode stand: Optional,GLP Features: Date: Time: Sample ID: Operator ID,Instrument: Bench,IP Rating: IP54 (Resistant to spray of water: Dustproof),ISE Direct Measurement Range: Yes,ISE Electrode Calibration: 2 - 5 points,Kit (Yes/ No): No,Lock Function: Continuous / Auto-stabilization (`pressto read`) / At Interval,Measurement method: Probe specific programmedmethod settings,mV Measurement at Stable Reading: Yes,mV Measurement Range: -1500 - 1500 mV,mV Resolution: 0.1 mV,Needed Cable Length: 2m or more,Operating Error Messages: Clear text error messages,displayed,Operating Humidity: 90 % relative humidity (noncondensing),Operating Interface: Soft Touch Keypad,Operating Temperature: 0 -plus 60 °C (32 - 140 °F),ORP Electrode Calibration: Predefined ORP standards(including Zobell`s solution),Parameter: pH/ Oxydo Reduction Potential (ORP)Conductivity/Total Dissolved Solid,,(TDS)/Salinity/Resistivity,Dissolved Oxygen (DO)Biochemical Oxygen Demand (BOD),Ion Selective Electrode (ISE): Ammonia, Ammonium,Chloride, Fluoride, Nitrate, Sodium,PC Data Transfer Software: HQd Series Meter DataTransfer Utility,pH Buffer Sets: Color-coded: 4.01, 7.00, 10.01 pH:,IUPAC: 1.679, 4.005, 7.000, 10.012, 12.45 pH DIN: 1.09, 4.65, 9.23 pH User-defined custom buffer sets,pH Electrode calibration: 1 - 3 Calibration points,Calibration summary data logged and displayed,pH Measurement Range: 0 - 14 pH,pH Resolution: Selectable:0.001/0.01/0.1 pH,Printer: Yes, Optional,Probes included: DO, pH and conductivity/TDS,Resistivity Measurement: 2.5 ?.cm - 49 M?.cm,Resistivity Resolution: 0.1,Salinity Measurement Range: 0 - 42 (ppt) (‰),Salinity Resolution: 0.01 (ppt) (‰),Simultaneous measurements: Yes,TDS Measurement Range: 0.00 mg/L - 50.0 g/L asNaCl,TDS Resolution: 0.01 mg/L - 0.1 g/L upon measuring range,Temperature Compensation: Automatic Temperature compensation for pH,Temperature Measurement: °C or °F,Temperature Range: -10°C - 110 °C,Temperature Resolution: 0.1Eutech,ThermoScientificOrion, WTW,Hach,Metrohm (with 5 years AMC)
6Pipette Controller Technical Specifications: It will be battery operated electronic pipette filling device and will have Ergonomic design and robust.The pipette must extend smooth operation. The device must have designed to be used for most of the plastic and glass pipettes having volume from 0.1-100 ml. The device must be autoclavable.It will be Light in weight so it can be used forcontinuous operation without fatigue and enablesingle handed operation with minimum efforts. It willhave Dual dispensing with a single knob: Theinstrument will have different modes for dropwise andslow dispensing for fast dispensing). The device willhave continuous pump speed adjustment duringliquid handling operations.It will have replaceable PTFE hydrophobic membranefilter (0.2microns) to prevents aerosol contaminationand accidental liquid entry. Other Technical specifications:Fit: Pipette made of Glass or plasticSize: Pipette of volume size 0.1 ml to 100 mlBattery: Li-On or Ni-Cd batteries,Battery charger: Compatible with both 220V and 110V,Battery indication: Low battery and charging ,indication Operation: Minimum 6 hr continuous operation,Autoclaving Parameters: Autoclavable at 121 °C and15 psi for a duration of 10-15 minutes.Warranty: 2 yearsMicrolit,Sartorius,Thermo FisherScientific,Brand, Glassco,Borosil
7Turbidity meter(Benchtop)/ (Portable)Range: 0-4000 NTU: Certification: CE, FCC, EC, EN, UL STD,Communication: RS 232, USB via adapter,Compliance: ISO,Data Log: 1000 total logs, includes reading log,verification log and calibration log, Date Time, User ,Display: LCD graphic, backlit, menu controlled,Interface: RS 232, USB via adapter, external printer,barcode scanner, PC ,Light source: Light-emitting diode (IR LED)/ TungstenFilament Lamp,Measurement method: Nephelometric,Operating temperature range: 0 - 50 °C,Power requirements (Voltage): 100 - 240 VAC with Lab station, ,Battery Operated 4 x 1.5 V, type AA for,approx. 3,000 measurements Resolution: 0.001 NTU: Repeatability ±1% of reading or 0.01 NTU whichever is greaterAccuracy: ± 2% of reading plus 0.01 NTU from 0 -1000 NTU, ±5% of reading from 1000 - 4000 NTU or better ,Reading Modes: Single, Intelligent Reproducibility and Plausibility Check (IRPC) procedure ,Regulatory: Meets ISO 7027, DIN EN 27027 Response time: (15 seconds 28x60 mm (1.10x2.36 in.), 20 ml sample volume Calibration Point Automatic 3-point calibration Weight approx. 0.6 kg (without batteries),Dimension 236 x 86 x 117 mm,Source Lamp: LED Stabilization time: Immediately,Storage conditions: -20 to 65 °CUnits: FNU and NTU Relative Humidity Yearly mean: ( 75 %: 30 days/year:95 %: Other days: 85 %, Type of Protection: IP 67(with 5 years AMC)

AI Tender Summary

OUR REF NO 44305935
AUTHORITY Government Departments
TENDER VALUE 8.86 Lakhs
LAST DATE 29-07-2024
Authority
Authority Name Public Health Engineering Department
Work Description Supply installation and commissioning of water testing equipments PHE Lab Rohtak under Jurisdiction of PHE Divn.No-2 Rohtak Distt. Rohtak`-- 1 Autoclave Vertical • Size-78 ltr/ 98 ltr • It should have double wall construction with boiler made of Stainless Steel 16-gauge sheet. Outer shell is also made of Stainless-Steel Sheet/ Mild Steel. Boiler and outer shell are provided with air insulation. Lid is made of Stainless-Steel Sheet and tightened all-round by radial locking. Joint less gaskets are made of Neoprene rubber. These sterilizers are hydraulically tested up to 40 PSI. • Should have fully automatic PID Controller • Automatic timer electronic 999 mtsSterilizers are fitted with water level arrangementto indicate water position inside the boiler. Pressure gauge, Air/Steam release cock two safety valve are also provided. The autoclave is fittedwith indfoss pizzostat and can be set between 10 to 20 PSI. • Immersion type heating element heats the water and steam to desired temp. and pressure are attained. We have provided all autoclaves to cutoff automatically when the autoclave is dry. Supplied complete with S.S. basket, cord and plug to work on 220 Volts 50 cycles A.C. supply • Traceability calibration certificate of controller should be provided • Instrument should be calibrated from NABL calibration laboratory. • Includes AMC for 5 years Make Popular, NST, Ambassador 2 Bacteriologic al incubatorInner Size: 18` x 18` x 24`, Rating Watts 750, No. ofShelves 3, capacity 120Ltrs Construction: Doublewalled construction outer body made of Mild Steelpowder coated, and Inner Body made of Stainless-SteelInsulation: Glass wool insulation between two walls.Temp range: room temperature to 60°C. Accuracy: plus /- 0.5 °C. Temp controlled by: Controlled by PIDMicro process controller with dual display. Selves:With G.I. wire Mesh selves Door: 2 door inner acrylicdoor to view sample and outer metal door. with aircirculation motor with blower for uniformtemperature throughout chamber. Heater: specialNichrome heater designed for long life and saving of power consumption 3 Colour Comparator for colour,Applicable Standard ASTM D1209 ISO 6271,Colour Type Transparent,Portability: PortableRange-Visual Colour Grading of PlatinumCobalt/Hazen/APHA Colour (Range 0 - 250 mg),Disc-NSB Hazen scale disc Range: -70 - 250 mg Pt/l,CAA Hazen scale disc Range: -0-30 mg Pt/l,CAB Hazen scale disc Range: -30-70 mg Pt/l,(The bidder should provide Colour Glass disc),Nessleriser,1 X Pair Nessleriser Daylight 2000 plus ,1 X Pair Stand for Nessleriser Unit,1 X Pair 2150 Nessleriser body,1 X Pair 2250 Nessleriser body,1 X Pair of Nessler cylinder AF306P,1 X Pair of Nessler cylinders 250mm,DB420,Certification,The company should have ISO Certification for,manufacture Water testing Instruments (NST,Ambassador,OpticsTechnology) 4 Digital BuretteTechnical Specifications for Bottle top burette:1. The bottle top burette should have motorcontrolled piston movement.,2. There will be different speed modesa. Fast,b. Medium,c. Slow to control dispensing speeds and to facilitate,accurate titrations.3. Bottle top burette should be able to dispense adroplet as small as 0.01 ml to ensure highly accurate end point. 4. It will have re-circulation mode that allows quickpurging without loss of reagent. to provide ease ofuse and save time, the burette should provide onetouch filling operation and refilling should be donewithout change in on-screen reading.5. Capacity: 50 ml 6. Increment: 0.01 ml 7. Systematic Error: Precise titration with the error limits of Class A: = 0.1% at nominal volume 8. Random Error: =0.02% at nominal volume(Microlit,Sartorius,Thermo FisherScientific,Brand, Borosil) 5 Multi-meterwith pH,Conductivity and DOAutomatic Buffer Recognition: Yes,Backlight: Yes,Barometric Pressure Measurement: Automatic,compensation of DO when using an LDO or LBOD,probe,Calibration: Demal (1D/ 0.1D/ 0.01D).,Molar (0.1M/ 0.01M/0.001M),NaCl (0.05%: 25µS/cm: 1000µS/cm: 18mS/cm)Standard sea water,User defined Calibration Intervals/Alerts/Reminder:Off, selectable from 2 hours to 7 days,Communication: Integrated USB type A (for USB 2.0 flash memory device, printer, keyboard) and Integrated USB type B (for PC) Compliance Certifications: CE. WEEE (Certifications are applicable only for European Union and USA)Conductivity measurement: Yes Conductivity measurement: Temperature correction:None: Linear: NaCl Non-Linear Natural Water. Conductivity Measurement Range: 0.01 µS/cm -200.0 mS/cm Conductivity resolution: 0.01 µS/cm - 0.1 mS/cm upon selected measuring range Contents: Meter Only,Custom Calibration Standards: Yes ,Data Export: Download via USB connection to PC or,flash memory device. Automatically transfer entire ,data log or as readings are taken., Data Memory: 500 records/FIFOData Storage: Automatic, GLP ISO compliant reading data stored with calibration details. Dimensions: 859 x 175 x 235 mm,Display: Detailed mode/Large mode,Display Type: 440 x 160-pixel LCD with backlight,illumination,DO Measurement Range: 0.1 - 20.0 mg/L (ppm) 1 -200% saturation,DO Resolution: 0.1,DO sensor calibration: • 100% (water-saturated air,(100%) calibration,• 100% with 0 (water-saturated air (100%) calibration with 0 point,• mg/L (calibration with a specified dissolved oxygen,concentration (mg/L) solution),• mg/L with 0 (calibration with a specified dissolved,oxygen concentration (mg/L) solution with 0 point)• Factory (calibration with the default LDO calibration) ,Electrode stand: Optional,GLP Features: Date: Time: Sample ID: Operator ID,Instrument: Bench,IP Rating: IP54 (Resistant to spray of water: Dustproof),ISE Direct Measurement Range: Yes,ISE Electrode Calibration: 2 - 5 points,Kit (Yes/ No): No,Lock Function: Continuous / Auto-stabilization (`pressto read`) / At Interval,Measurement method: Probe specific programmedmethod settings,mV Measurement at Stable Reading: Yes,mV Measurement Range: -1500 - 1500 mV,mV Resolution: 0.1 mV,Needed Cable Length: 2m or more,Operating Error Messages: Clear text error messages,displayed,Operating Humidity: 90 % relative humidity (noncondensing),Operating Interface: Soft Touch Keypad,Operating Temperature: 0 -plus 60 °C (32 - 140 °F),ORP Electrode Calibration: Predefined ORP standards(including Zobell`s solution),Parameter: pH/ Oxydo Reduction Potential (ORP)Conductivity/Total Dissolved Solid,,(TDS)/Salinity/Resistivity,Dissolved Oxygen (DO)Biochemical Oxygen Demand (BOD),Ion Selective Electrode (ISE): Ammonia, Ammonium,Chloride, Fluoride, Nitrate, Sodium,PC Data Transfer Software: HQd Series Meter DataTransfer Utility,pH Buffer Sets: Color-coded: 4.01, 7.00, 10.01 pH:,IUPAC: 1.679, 4.005, 7.000, 10.012, 12.45 pH DIN: 1.09, 4.65, 9.23 pH User-defined custom buffer sets,pH Electrode calibration: 1 - 3 Calibration points,Calibration summary data logged and displayed,pH Measurement Range: 0 - 14 pH,pH Resolution: Selectable:0.001/0.01/0.1 pH,Printer: Yes, Optional,Probes included: DO, pH and conductivity/TDS,Resistivity Measurement: 2.5 ?.cm - 49 M?.cm,Resistivity Resolution: 0.1,Salinity Measurement Range: 0 - 42 (ppt) (‰),Salinity Resolution: 0.01 (ppt) (‰),Simultaneous measurements: Yes,TDS Measurement Range: 0.00 mg/L - 50.0 g/L asNaCl,TDS Resolution: 0.01 mg/L - 0.1 g/L upon measuring range,Temperature Compensation: Automatic Temperature compensation for pH,Temperature Measurement: °C or °F,Temperature Range: -10°C - 110 °C,Temperature Resolution: 0.1Eutech,ThermoScientificOrion, WTW,Hach,Metrohm (with 5 years AMC) 6 Pipette Controller Technical Specifications: It will be battery operated electronic pipette filling device and will have Ergonomic design and robust.The pipette must extend smooth operation. The device must have designed to be used for most of the plastic and glass pipettes having volume from 0.1-100 ml. The device must be autoclavable.It will be Light in weight so it can be used forcontinuous operation without fatigue and enablesingle handed operation with minimum efforts. It willhave Dual dispensing with a single knob: Theinstrument will have different modes for dropwise andslow dispensing for fast dispensing). The device willhave continuous pump speed adjustment duringliquid handling operations.It will have replaceable PTFE hydrophobic membranefilter (0.2microns) to prevents aerosol contaminationand accidental liquid entry. Other Technical specifications:Fit: Pipette made of Glass or plasticSize: Pipette of volume size 0.1 ml to 100 mlBattery: Li-On or Ni-Cd batteries,Battery charger: Compatible with both 220V and 110V,Battery indication: Low battery and charging ,indication Operation: Minimum 6 hr continuous operation,Autoclaving Parameters: Autoclavable at 121 °C and15 psi for a duration of 10-15 minutes.Warranty: 2 yearsMicrolit,Sartorius,Thermo FisherScientific,Brand, Glassco,Borosil 7 Turbidity meter(Benchtop)/ (Portable)Range: 0-4000 NTU: Certification: CE, FCC, EC, EN, UL STD,Communication: RS 232, USB via adapter,Compliance: ISO,Data Log: 1000 total logs, includes reading log,verification log and calibration log, Date Time, User ,Display: LCD graphic, backlit, menu controlled,Interface: RS 232, USB via adapter, external printer,barcode scanner, PC ,Light source: Light-emitting diode (IR LED)/ TungstenFilament Lamp,Measurement method: Nephelometric,Operating temperature range: 0 - 50 °C,Power requirements (Voltage): 100 - 240 VAC with Lab station, ,Battery Operated 4 x 1.5 V, type AA for,approx. 3,000 measurements Resolution: 0.001 NTU: Repeatability ±1% of reading or 0.01 NTU whichever is greaterAccuracy: ± 2% of reading plus 0.01 NTU from 0 -1000 NTU, ±5% of reading from 1000 - 4000 NTU or better ,Reading Modes: Single, Intelligent Reproducibility and Plausibility Check (IRPC) procedure ,Regulatory: Meets ISO 7027, DIN EN 27027 Response time: (15 seconds 28x60 mm (1.10x2.36 in.), 20 ml sample volume Calibration Point Automatic 3-point calibration Weight approx. 0.6 kg (without batteries),Dimension 236 x 86 x 117 mm,Source Lamp: LED Stabilization time: Immediately,Storage conditions: -20 to 65 °CUnits: FNU and NTU Relative Humidity Yearly mean: ( 75 %: 30 days/year:95 %: Other days: 85 %, Type of Protection: IP 67(with 5 years AMC)
Basic Detail
Tender No 20248D1AEF44 B437 4F3E 8EF8 2503CF33B4F7577PUH
Bidding Type Tender
Location
City rohtak
State Haryana
Key Dates
Publish Date 19 Jul 2024
Submission Date 29 Jul 2024
Open Date 29 Jul 2024
Finance
Tender Value 8.86 Lakhs
Tender Fee 1000
EMD 17720
Exemption Available
Document List
fdd004dd-14c7-46e0-bceb-1a685827694e.html
BOQ_468414.xls
OT0070473.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 19, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 29, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 29, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

fdd004dd-14c7-46e0-bceb-1a685827694e.html

xls

BOQ_468414.xls

pdf

OT0070473.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders