| 1 | Excavation in trenches n.exc 1.5mtr wide and not exc 1.5mtr depth and getting out insoft/loose soil all as directed. |
| 2 | Returning and filling in of excavated soil including spreading,levelling,watering and well ramming in layers not exceeding 25 cm each. |
| 3 | Removal of surplus soil not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point. |
| 4 | M&L for PCC 1:4:8 type D2 with 40 mm graded aggregate as in foundation complete including demolition of the same complete all as directed. |
| 5 | M&L for PCC 1:3:6 with 20 mm graded aggregate for coping of poles and stay including form work including demolition of the same complete all as directed. |
| 6 | M&L for Sand cushioning/sand coveringfor underground cable protection complete all as specified.Note: Punned thickness only will be measured and paid. |
| 7 | Supply and laying sub class \"B\" bricks of old size (standard size as per local availability) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge |
| 8 | S&F of MS steel angle iron work as in struts and posts in fencing including cutting tops to shape as directed ,drilling holes notching for wire any flat iron fillets (for securing wire mesh and any wire type) including drilling,bolting or riverting and embedding in angle irion and screwing etcsimilar work & finally paintingthe entire exposed steel surface withtwo coats of first quality synthetic enamel paint over a coat of primer after necessary prepration of surface steel confirming toFe 410-0 orFe 310-0(Note: Quoted rate isdeemed tobe inclusive ofpainting) |
| 9 | S&F of MS steel screw bolts(machine made) with hexgonal or square heads at ends and screwed end to be fitted with washers and one hexgonal or sqaure or square nuts not exc 30cm long and diameter of neck is 12mm complete all as specified as directed. |
| 10 | Supply only Chain link MS Galvanised fencing 50mm Mesh all as specified and directed |
| 11 | Fixing only chainlink fencing including line wires any mesh,size and type straining bolts including provision of binding wire. |
| 12 | Supply and fixing in repair GI tubing light grade 50 mm dia for protection of cable on pole , under road crossing or across drain , along electric pole or floor /wall along withsuitable size ofMS claps , nuts & bolts etccompleteall as specified and directed .( Note: Excavation / earth work shall be measured and paid separately under relevant items of Sch ‘A’ |
| 13 | All as per item No 12 here-in-before butdia of pipe 40 mm . |
| 14 | All as per item No 12 here-in-before butdia of pipe 80 mm . |
| 15 | M&L for replacement of galvanised iron strip 32x6 mm buried in ground or fixed on pole with all accessories including dismantling old one. |
| 16 | Earthing complete with Galvanised Steel earthplate of size 60x60cmx6.3mm thick electrode and 32x6mm GI strip as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to 32x6mm earth strip by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.5 of SSR Part-I, connected to earth test terminal point all as specified or as indicated including testing on completion (Rates inclusive of neccessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc. all as required at site for complete earthing). |
| 17 | M&L cable jointing kit for11 KV (Earthed) grade XLPE cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable forsize 3 core 120 to 185 Sqmm including testing after jointing complete all as directed . |
| 18 | M&L cable jointing kit for11 KV (Earthed) grade XLPE cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable forsize 3 core 50 to 95 Sqmm including testing after jointing complete all as directed . |
| 19 | M&L cable jointing kit for11 KV (Earthed) grade XLPE cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 240 Sqmm including testing after jointing complete all as directed . |
| 20 | M&L cable jointing kit for11 KV (Earthed) grade XLPE cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 120 to 185 Sqmm including testing after jointing complete all as directed . |
| 21 | M&L cable jointing kit for11 KV (Earthed) grade XLPE cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminium conductor cable of size 50 to 95 Sqmm including testing after jointing complete all as directed . |
| 22 | S&L XLPE insulated,screened, PVC bedded galvanised steel strip or wire armoured ,electric power cables heavy duty with aluminium conductor, 11000 Volts grade ( earthed) of size 3 core 95 Sqmm complete in trenches/ ducts/ on pole etc complete all as directed . Make: Universal/ Nicco/ Polycab |
| 23 | M&L for detecting HT/ LT UG cable faults located in any stretch/ depth with sophisticated cable fault locator consisting of microprocessor based pre-locator system, HV surge generator, fault pin point surge wave reciever, cable indentification instrument , cable tracer for exact location of under ground cable routes. Note: The rate quoted deemed to be inclusive of rental charges for T&P like entire cable fault locating instrument, Charges for operator and transportation etc complete |
| 24 | Provision of trenchless bore using mechanical numatic drilling equipment for passing electric cables through HDPE pipe of 100mm dia under the existing bituminous/WBM road/PCC hard standings, depth range not less than 1.0 mtr and upto 1.5mtr and making good to the distrubed surfaces of road to match with its existing specifications all as specified and directed by engr-in-charge at site. Note : 1. Quoted rates deems to be inclusing of necessary earth work, transportation charges of Drilling machine, and cost of HDPE pipe and passing pipe through bore complete.2. Any damage to MES assets caused during trenchless bore shall be recitfied by the contractor at his own cost. |
| 25 | Material & labour for decarbonising of LT panel board of any size/ capacity made out of thermoplastic-polycarbonate boxes with IP-65 protection by taking shut down of panel & strip opening of boxes carefully, cleaning the carbon content with CTC solution, replacement of embedded polyurethane gasket,replacement of pitted control wiring, thimbles ,replacement of nuts, bolts ,washers, cable glands/ PVC gromates, cable lugs,tightening the busbar chamber, dismantling the broken/ defective boxes, inspection of Ammeters/ Voltmeters/ Multifunction meters re-assembling after replacement of new boxes, testing & commissioning,INCLUDING painting with a coat of synthetic enamel spray painting all as per existing colour complete all as directed. Note :The defective thermoplastic-polycarbonate boxes, LED Lamps,Ammeters , Voltmeters, Multifunction meters, CTswill be measured and paid separately under relevant schedule items . |
| 26 | Supply & fix in repairthe following spares for carrying out repairs to any type ofLT Panels :- (a) Multifunction meter for measuring Volt/ Amp/ frequency meter with inbuilt selector switch class 0.5/1.0 , 230 V AC Aux supply 96x96 Sqmm size suitable for 5A CT. Make: Neptune /Schneider /L&T /Havells/ EPCOS/Hager / ABB |
| 27 | (b) Digital Ammeter for measuring Amps with inbuilt selector switch class 0.5/1.0 , 230 V AC Aux supply 96x96 Sqmm size suitable for 5A CT. Make: Neptune /Schneider /L&T /Havells/ EPCOS/Hager / ABB |
| 28 | (c) Digital Voltmeter for measuring Voltage with inbuilt selector switch class 0.5/1.0 , 230 V AC Aux supply 96x96 Sqmm size. Make: Neptune /Schneider /L&T /Havells/ EPCOS/Hager / ABB |
| 29 | (d) CTs moulded type class-1.0, 5VA burden suitable for AC 230V (phase-earth )50 Hz supply busbar system of suitable for ratio range 100 to 800/5 Amps capacity |
| 30 | (e) LED Indication LampsMake: Neptune/L&T /Schneider/ /Havells/EPCOS/Hager / ABB |
| 31 | Supply & Laying in trenches or fixing on wall or passing through pipe or in cable ducts,16 Sqmm , 4 Core ,1100 volts gradeXLPE insulated , armoured, electric power cables (heavy duty) with aluminium conductor,including dismantling old one.Note: The rate quoted inclusive of termination at ends with suitable aluminium lugs ,Cremping ,Glanding wherever required. |
| 32 | All same as per itemNo 31 here-in-above but25 Sqmm 4 core |
| 33 | All same as per itemNo 31 here-in-above but3.5 core 35 Sqmm |
| 34 | All same as per itemNo 31 here-in-above but 3.5 core 50 Sqmm |
| 35 | All same as per itemNo 31 here-in-above but3.5 core 70 Sqmm |
| 36 | All same as per itemNo 31 here-in-above but3.5 core 95 Sqmm |
| 37 | All same as per itemNo 31 here-in-above but3.5 core 120 Sqmm |
| 38 | All same as per itemNo 31 here-in-above but3.5 core 150 Sqmm |
| 39 | All same as per itemNo 31 here-in-above but3.5 core 185 Sqmm |
| 40 | M&L for dismantling the cable connections offour pole/ three pole Air circuit breakerof capacity 630 to 800 Amps ,415 V 50 HZ of L&T Make/C&S/GE/ABB make, strip opening the Air circuit breaker, inspecting the parts for serviceability/overhauling complete and carrying out the following repairs/maintenance :- a) Cleaning the insulation parts including bushings with CTC solution.b) Checking the alignment and condition of movable and stationary contacts and adjust them all as per manufacturer\"s instructional manual c) Check the bolts, nuts, washers, cotter pins and all terminal connections are in place and tights. Replace the worn-out parts.d) Check arc chutes for damage .e) Clean and lubricate the operating mechanism with a light machine oilfor pins and bearings and with a non-hardening grease for the wearing surfaces . Adjust breaker operating mechanism all as per manufacturer\"s instructional manual . f) Checking / inspectingshunt trip coil for serviceability and replacing the same if required. g) Checking control device free for operation.j) Check after servicing the circuit breaker to verify the contacts move to the fully opened and fully closed positions, that there is an absence of friction and that the electricaloperation is functional Note : The rate quoted deemed to be inclusive of T&P and minor spares like lubricants, nuts/bolts/washers/ pins etc. Major spares like Shunt release & trip coiletc will be measured & paid separately under relevant schedule items |
| 41 | Supply only CTs suitable for air circuit breakers of rating 630 Amps to 800 Amps as all per existing of Make: L&T/C&S/ GE/ABB/Havells/Hager |
| 42 | Supply only auxiliary contact block suitable for air circuit breakers of rating 630 Amps to 800 Ampsas all per existing of Make: L&T/C&S/ GE/ABB/Havells/Hager |
| 43 | Supply only arcing contacts (fixed/ moving)suitable for air circuit breakers of rating 630 Amps to 800 Amps as all per existing of Make: L&T/C&S/ GE/ABB/Havells/Hager |
| 44 | Supply only arc chutes (for 415 V) suitable for air circuit breakers of rating 630 Amps to 800 Amps as all per existing of Make: L&T/C&S/ GE/ABB/Havells/Hager |
| 45 | Supply only shunt release (110 /220 V DC or 240 V/415 V AC) suitable for air circuit breakers of rating 630 Amps to 800 Amps as all per existing of Make: L&T/C&S/ GE/ABB/Havells/Hager |
| 46 | Supply only cluster contact suitable for air circuit breakers of rating 630 Amps to 800 Amps as all per existing of Make: L&T/C&S/ GE/ABB/Havells/Hager |
| 47 | Supply only trip coil suitable for air circuit breakers of rating 630 Amps to 800 Amps as all per existing of Make: L&T/C&S/ GE/ABB/Havells/Hager |
| 48 | Supply & fixing in repairs ofMCCBs of following current carrying capacity including necessary connecting terminals to bus bar, nut bolts etc as per site suitable complete all as directed .(a) 125 Amps, 3P,Adjustable type, 415 V MCCB, 16KA ratingMake: L&T/Hager/Havells/ Indoasian/Schneider/ABB |
| 49 | All same as per itemNo 48 here-in-above but 100 Amps, 3P, 415 V MCCB, 16KA rating |
| 50 | All same as per itemNo 48 here-in-above but4 Pole MCCB, 415 V, Adjustable type with breaking capacity 36 KA, 400 A rated |
| 51 | All same as per itemNo 48 here-in-above but 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 250 A rated |
| 52 | All same as per itemNo 48 here-in-above but 4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 200 A rated |
| 53 | All same as per itemNo 48 here-in-above but4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 160 A rated |
| 54 | All same as per itemNo 48 here-in-above but4 Pole MCCB, 415 V, Adjustable type with breaking capacity 25 KA, 100A rated . |
| 55 | M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5/ 4 core 25 to 50 sq.mm.Make :- M-SEAL / BIRLA 3 M LTD /DENSON /RAY CHEM |
| 56 | All as per Item No.55 herein before but for cable of size 3.5 core 70 to 150 sq.mm. |
| 57 | All as per Item No. 55 herein before but for cable of size 3.5 core 185 to 400 sq.mm. |
| 58 | M&L for heat shrinkable end termination joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5/ 4 core 16 to 50 sq.mm.Make :- M-SEAL / BIRLA 3 M LTD /DENSON /RAY CHEM |
| 59 | M & L for disconnectingcarefully electrical connection of LT Automatic power factor correction (APFC) Panel of any existing Make:for supply range 3 Phase 415 V & 50 Hz system of 100 to 75 KVAR capacity installed at various locations, inspecting/servicing the APFC panel complete, calibration of meters, checking the serviceability of items such as MD-XL capacitors, capacitor duty contactors, APFC relay,MCCB/ACB/Contactors , replacing the pitted control wiring, ventilation fan, checking / replacing defective LED lamps/ Multifunciton meters/ Ammeters/Voltmeters/ Push button switches, CTS etc including replacement of pitted aluminium lugs of power cable/Aluminium conductor cable for connecting APFC panel to Main incoming panel etc complete, including re-assembling, painting with a coat of synthetic enamel spray painting all as per existing colour, including testing, commissioning etc complete all as speciifed and directed.Note :- (a) The rate quoted deemed to be inclusive replacement of copper control wiring, ventilation fan,calibration of meters, complete inspection/servicing of APFC panel for repairs.(b) Spares such as MCCBs,capacitors, capacitor duty contactors, APFC relay, LED lamps/ Ammeters/Voltmeters/ Push button switches, CTs , will be measured and paid separately.(c) The M/L PVC XLPE Aluminium conductor power cable will be measured and paid separately. |
| 60 | All same as per itemNo 59 here-in-above but35/45/25/10 KVAR |
| 61 | Supply only the following spares for carrying out repairs to APFC panel under relevant(a) Multifunction meter for measuring Volt/ Amp/ frequency meter with inbuilt selector switch class 0.5/1.0 , 230 V AC Aux supply 96x96 Sqmm size suitable for 5A CT. Make: Neptune /Schneider/L&T/Havells/EPCOS |
| 62 | (b) CTs moulded type class-1.0, 5VA burden suitable for AC 230V (phase-earth )50 Hz supply busbar system of suitable for ratio range125/5 Amps capacity |
| 63 | (c) LED Indication LampsMake: Neptune/L&T/Schneider//Havells/EPCOS |
| 64 | (d) LED type push button actuators.Make: Neptune/L&T/Schneider//Havells/EPCOS |
| 65 | (e) 6/10/16A, 10 KA MCB SP, C curve type Make: ABB/L&T/schneider //Havells/EPCOS |
| 66 | (f) 32 A 10 KA MCB TP, C curve type Make: ABB/L&T/schneider //Havells/EPCOS |
| 67 | (g) Capacitor duty contactor with 1 No Aux contact 230V AC coil voltage suitable for minimum 10 KVAR capacitor. Make: ABB/Schneider/L&T /Havells/EPCOS |
| 68 | (h) Capacitor duty contactor with 1 No Aux contact 230V AC coil voltage suitable for minimum 25 KVAR capacitor. Make: ABB/Schneider/L&T /Havells/EPCOS |
| 69 | (j) Double metalised paper and polypropylene technology ( Mixed Dielectric) capacitor cylindrical/box type for power factor correction of 440 V, 50 HZ rated of capacity 3 to 15 KVAR. Make: L&T/Neptune-Ducati / Schneider/Havells/EPCOS |
| 70 | (k) Double metalised paper and polypropylene technology ( Mixed Dielectric) capacitor cylindrical/box type for power factor correction of 440 V, 50 HZ rated of capacity 20 to25 KVAR. Make: L&T/Neptune-Ducati / Schneider/Havells/EPCOS |
| 71 | (l) Auto/Manual 3Pole, 2 WAY+OFF, selector switch Make: L&T Salzer/ Schneider/Havells/EPCOS |
| 72 | (m) APFC relay with inbuilt PF meter suitable for 5A CTR suitable for 8 Stage. Make: Neptune-Ducati RM-8/ L&T/ Schneider//Havells/EPCOS |
| 73 | (n) APFC relay with inbuilt PF meter suitable for 5A CTR suitable for 12 Stage. Make: Neptune-Ducati RM-12/ L&T/ Schneider//Havells/EPCOS |
| 74 | Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP – 31), 09 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole with and including necessary earth work in any type of soil and disposal of surplus soil to a distance not exceeding 50 mtr, PCC (1:4:8) type D-2 (using 40 mm graded sand stone aggregate) in the base and foundation upto ground level and PCC (1:2:4) type B-1 (using 20 mm graded black trap/granite/basalt stone aggregate) for coping of the pole including necessary form work including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint and including making alternate white and black strips 30 cms height (05 Nos strips) numbering the poles by 2\" height 06 Nos letters complete all the metallic surfaces all as specified and directed byEngineer-in-Charge. |
| 75 | Clearing of bushes/small plants upto root level around and surroundings areas E/M installations (i.e.Two Pole/ Four structures, outdoor-substation yards, pump house & STP installations etc)including surface dressing n.exc 15 cm deep and removing debris to a distance n.exc 50m complete all as directed |
| 76 | M & L for LT/HT cable route indicator marker of Cast iron (Round die) 4\" round plate with 3 mm thickness,MS angle of size 600 mm long,powder coated yellow colour and very clear fonts and clean moulding complete all as specified and directed by Engr-in-charge. |
| 77 | M&L for Removing/scraping old u/s paint of LT panel boart any size/model and painting two coat of aluminium paint over one coat of primer red oxided all as specified . |
| 78 | Design, fabrication, installation and testing of LT out door type factory made(CPRI Approved), junction box of size 900mm(H)X700mm(B)X400mm(W) (over all dimension) made out of3.0mm thick CRCA sheet dully supported with mild steel angle iron of size 40X40X5 mm frame, 04 Nos aluminium bus bar ofcapacity 250 Amps with drilled hole for incoming/outgoing cableconnection with necessary aluminium lugs, GI nuts bolts and washer including 08 Nos bridge insulator DMC , heavy duty, suitable for 3 Phase 4 wire system, one danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white with letters, figures and conventional skull & bones in signal red colour and fixed in front door size and PCC (1:3:6) type C-1 foundation 0.30m above normal ground level & 0.30m below ground levelwith necessary exacavation and earth work and painting to internal and external steel surface with powder coated (Siemence grey) RL-35 after neccesary preparation of surfacesincluding Indicatinglamp LED type 240V 50 Hz AC -one set of 3Make: L&T/Legrand/ ABB/Siemens/Havellscompete all as directed. |
| 79 | Design, Fabrication, supply, installation, commissioning and testing Double Door Panel board manufactured from CPRI approved firm with canopy head, out door,cubical type panel board of over all min dimension 1.2 m (L) X 1.00m (H) X 0.50m (W) fabricated with 3.0mm thick CRCA sheet on mild steel angle iron 50X50X6 mm thick frame, totally enclosed type dust & vermin proof back side open-able fixed with hinged shutter and front side open-able with hinged shutter and locking arrangement for individual MCCBs/MCBs , powder coated finished both internally and externally suitable for 415Volt AC 50 Hz 3 Phase4 wire system by means of Alluminium bus bar of600 Amps Capacity (Main bus bar )and 800 Amps Loop Bus barwith coloured insulating tape/sleeves mounted on porcelain or synthetic insulators with provision for fixing MCCBs/MCBsnecessary inter connections withAluminium bar/strip dulycoloured code insulation and providing under mentioned equipments & accessories including connections of all out going/in coming existing/New cables of required size and including PCC foundation in 1:3:6, type C1 of 0.5 mtrs heightabove GL and 0.30mtrs below GL including necessary earth workcomplete all as specified and as directed. (a)INCOMING: MCCB 4 pole 450Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals - 01NoMake: L&T/Legrand/ ABB/Siemens/Havells (b)OUTGOING:MCCB 4 pole 160Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals-03 Nos Make: L&T/Legrand/ ABB/Siemens/Havells (c)O/G MCCBTPN63Amp, 10KA,C curve - 02 Nos . Make: Legrand cat No 408683 or equivalent model of L&T/ ABB/Siemens/Havells. (d)Indicatinglamp LED type 240V 50 Hz AC -one set of 3.Make: L&T/Legrand/ ABB/Siemens/Havells |
| 80 | Design, Fabrication, supply, installation, commissioning and testing Double Door Panel board manufactured from CPRI approved firm with canopy head, out door,cubical type panel board of over all min dimension 900mm(H)X700mm(B)X400mm(W)fabricated with 3.0mm thick CRCA sheet on mild steel angle iron 50X50X6 mm thick frame, totally enclosed type dust & vermin proof back side open-able fixed with hinged shutter and front side open-able with hinged shutter and locking arrangement for individual MCCBs/MCBs , powder coated finished both internally and externally suitable for 415Volt AC 50 Hz 3 Phase4 wire system by means of Alluminium bus bar of400 Amps Capacity (Main bus bar )and 400 Amps Loop Bus barwith coloured insulating tape/sleeves mounted on porcelain or synthetic insulators with provision for fixing MCCBs/MCBsnecessary inter connections withAluminium bar/strip dulycoloured code insulation and providing under mentioned equipments & accessories including connections of all out going/in coming existing/New cables of required size and including PCC foundation in 1:3:6, type C1 of 0.5 mtrs heightabove GL and 0.30mtrs below GL including necessary earth workcomplete all as specified and as directed. (a)INCOMING: MCCB 4 pole 250Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals - 01NoMake: L&T/Legrand/ ABB/Siemens/Havells (b)OUTGOING:MCCB 4 pole 160Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals-03 Nos Make: L&T/Legrand/ ABB/Siemens/Havells (c)O/G MCCBTPN100-63Amp, 10KA,C curve - 02 Nos . Make: Legrand cat No 408683 or equivalent model of L&T/ ABB/Siemens/Havells. (d)Indicatinglamp LED type 240V 50 Hz AC -one set of 3.Make: L&T/Legrand/ ABB/Siemens/Havells |
| 81 | Design, Fabrication, supply, installation, commissioning and testing Double Door Panel board manufactured from CPRI approved firm with canopy head, out door,cubical type panel board of over all min dimension900mm(H)X700mm(B)X400mm(W) ) fabricated with 3.0mm thick CRCA sheet on mild steel angle iron 50X50X6 mm thick frame, totally enclosed type dust & vermin proof back side open-able fixed with hinged shutter and front side open-able with hinged shutter and locking arrangement for individual MCCBs/MCBs , powder coated finished both internally and externally suitable for 415Volt AC 50 Hz 3 Phase4 wire system by means of Alluminium bus bar of400 Amps Capacity (Main bus bar )and 800 Amps Loop Bus barwith coloured insulating tape/sleeves mounted on porcelain or synthetic insulators with provision for fixing MCCBs/MCBsnecessary inter connections withAluminium bar/strip dulycoloured code insulation and providing under mentioned equipments & accessories including connections of all out going/in coming existing/New cables of required size and including PCC foundation in 1:3:6, type C1 of 0.5 mtrs heightabove GL and 0.30mtrs below GL including necessary earth workcomplete all as specified and as directed. (a)INCOMING: MCCB 4 pole 315 Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals - 01NoMake: L&T/Legrand/ ABB/Siemens/Havells (b)OUTGOING:MCCB 4 pole 200Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals-01 Nos Make: L&T/Legrand/ ABB/Siemens/Havells(c) MCCB 4 pole 160Amp,Icu=Ics=25KA, Adjustable thermal and adjustable Magnetic setting with extended terminals-03 Nos Make: L&T/Legrand/ ABB/Siemens/Havells (d)O/G MCCBTPN100-63Amp 16A,C curve - 01 Nos .L&T/ ABB/Siemens/Havells. (e)Indicatinglamp LED type 240V 50 Hz AC -one set of 3.Make: L&T/Legrand/ ABB/Siemens/Havells |
| 82 | S&F single side painted flex glow sign board of 1.80X1.00X0.25 Mtrssize fabricated with 20mmmild steel square hollow pipe frame work, front side and back sidecoveredwith Aluminium sheet side openable typeincluding writing latter diagram, photoghraphy and making design covering the front surface as directed by Engr-in -Charge including providing 2X20 Watt LED tube light inside sign board for glow with necessary electrical connection.Glow sign board shall be standed at 1.2 mtrs above ground level by means of 40X40X5mm thick MSangle iron post duly embeded inPCC 1:3:6 type C1 foundation block of size 300X300X450mm depth, painting to iron members complete all as directed. |
| 83 | Electrically dicconnection of transformer any capacity & KVAinstalled in any description , Shifting of transformer from one place to another place by means ofHydra /Craneor other transport etc to a distancenot more than 5 Km in sideASC Centre primises , placing in/over platform/foundation of Transformer , making necessary electrical installation & testing on completion to the satisfaction ofEngineerr-in-Chargecomplete allas directed. |