Tender For Construction Of Solar System Water Reservoir At Ujjwal Hat Under Dharmapur Gp
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Jul 2024
0 days left
EMD
7000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
maynaguri → West Bengal
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Solar System Water Reservoir At Ujjwal Hat Under Dharmapur Gp
BOQ
| Sl. No. | Item Description |
| 1 | Description of work/ supply materials |
| 2 | Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete...(i)50 mm dia. boring etc. |
| 3 | Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete...(i)100 mm dia. boring etc |
| 4 | Supplying PVC strainer of approved make with adapter conforming to I.S.12818 specifications. |
| 5 | Supplying, fitting and fixing plug of approved make conforming to I.S. specifications. |
| 6 | Supplying,fitting and fixing check valve (horizontal) G.M. tested to 21 kg per sq. cm. |
| 7 | Supplying, fitting and fixing heavy type bell mouth reducing socket. |
| 8 | Supplying, fitting and fixing heavy type bell mouth reducing socket. |
| 9 | 50 mm dia |
| 10 | Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. |
| 11 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer(b) 1500 litre capacity |
| 12 | (g) Supplying, fitting and fixing alloy iron with brass spindle bib cock/ stop cock of approved brand and make, spray painted and tested to 21 kg per sq. cm.(i) 15 mm |
| 13 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary |
| 14 | (II) Cement concrete with 30 mm down graded shingles excluding shuttering.N.B. VarietyIn ground floor |
| 15 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (ii ) River Bazree |
| 16 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for |
| 17 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to |
| 18 | Rienforcement for rcc works |
| 19 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite |
| 20 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 21 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : |
| 22 | Supply , transport , installation and commissioning of Solar PV installation for water pumping system with fixed structure consisting of solar panels framed in anodized aluminium frame mounted on stable hot dipped galvanized (with80 micron thickness) mild steel structure of sufficient strength which can withstand load of modules and high wind velocities upto 150 Km/hr, having RCC foundation designed against all possible loads (Dead, Live and imposed load). Modules supplied with the SPV system should have certificate as per IEC 61215 specification or equivalent National or International standards and must be interconnected with 4/6 sq.mm cables routed in PVC conduits properly fitted along the G.I structure to provide a good aesthetic view. Modules must qualify to IEC 61730 part I and part II for safety qualification testing. The power output of individual PV modules used in the PV array, under STC, should be a minimum of 250 Watts peak, with adequate provision for measurement tolerances. Solar cells should be crystalline silicon cell with min. efficiency of 14% and fill factor more than 70%, should be laminated between sheet of -Ethylene Vinyl Acetate (EVA) and high transmissivity 3.2mm tempered glass including appropriate DC to AC inverter and power controlling unit (protected with IP65 class enclosure) with MPPT technology to run at low sunshine and minimum 5 hours a day run with all necessary accessories suitable for solar + grid operation and including all protections of AC induction motor pump. There should be a display of all measurable parameters including storing of data at a set interval and transfer it in a pendive thru USB port . There should also be provision of interfacing GPRS based data transmission. (The rate is inclusive of manufacturer\"s warranty and comprehensive maintenance for 1st year and comprehensive maintenace for 4 years beyond |
| 23 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By ISI-Medium GI pipe |
| 24 | Connecting the equipment to the earth busbar incl. S&F GI wire of size bellow on wall /floor as required and making connection to the equipment with bolts, washers, cable lugs etc. as required and mending good damages.No 4 SWG GI wire |
| 25 | Installation of submersible electro motor pumping set of following capacities by using necessary requisite, tools and plants by lowering the same within the tubewell housing pipe upto the following depth as per direction by fitting, fixing column pipes and other accessories, fixtures with necessary nuts, bolts and washers and suspending the entire assembly of pump set vertically by fixing the same supported by M.S. clamps over the top of housing pipe, binding the motor cable with each column pipes and drawing cable upto pump controller/starter point including opening out of the top cap of housing pipe of the tubewell and testing of motor both in loading as well as in unloaded condition before and after installation of the same. (The rate is inclusive of hiring charges of tools & plants.)(b) 30 cubic metre per hour capacity electro motor pumping set.(i) Length of pump assembly not exceeding 18 metre length |
| 26 | Supply, Installation, tesing & lowering of 1 HP oil solar submersible pump motor set complete having suitable dischage as per yeld test of well. Submerisble cable of 30mtr 3 core 2.5 sqmm that cable (Finolex) with MOC bar chart (KSB make Pump) and necessary control panel and starter as per manufacturar specifications. |
| 27 | WRDD SCHEDULE,Page - 114 / Item - 2(i)Supplying , fitting and fixing of Sand Filter - Manual as per IS:14606Sand Filter10m³/hr-M Single |
| 28 | Supplying 1 m × 0.6 m × 24 swg MS board containing list of spout wise water users by making numbers of spout as directed by EIC. The board should have base colour - Black and words - White to be fitted and fixed on the wall of the pump house. |
| 29 | Add GST @ 18 % |
| 30 | Add Cess @ 1% |
AI Tender Summary
Tender Timeline
Jul 18, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedJul 27, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJul 29, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender