| 1 | M&L for preparation old decorated plastered and unplastered surfaces of walls and cornices, spoiled by smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots by scraping and washing with water and applying one coat of white/colour washcomplete all asspecifiedand directed by Engineer-in-Charge. Note:-work can carried out upto fourth storey/hanger |
| 2 | M&L for preparation old decorated plastered and unplastered surfaces of walls and cornices, spoiled by smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots by scraping and washing with water and applying two coats of white/colour washcomplete all asspecifiedand directed by Engineer-in-Charge. Note:-work can carried out upto fourth storey/hanger |
| 3 | M&L for preparation old decorated plastered and unplastered surfaces of ceiling and cornices, spoiled by smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots by scraping and washing with water and applying one coat of white/colour washcomplete all asspecifiedand directed by Engineer-in-Charge.Note:-work can carried out upto fourth storey/hanger |
| 4 | M&L for preparation of plastered or unplastered old decorated surfaces of walls all as specified and filling cracks/hole by applying walls and ceiling putty (multipurpose mixer will be used for uniform and proper mixing of putty) and applying one coat of distemper oil emulsion white or coloured by auto roller complete incl removal of nails etc and grinding where necessary all as specified & directed by Engr-in-Charge. Note:- work will be executed by mechinised means/ tools as required for smart periodical services and work can carried out upto fourth storey. |
| 5 | M&L for preparation of plastered or unplastered old decorated surfaces of walls all as specified and filling cracks/hole by applying walls and ceiling putty (multipurpose mixer will be used for uniform and proper mixing of putty) and applying two coats of distemper oil emulsion white or coloured by auto roller complete incl removal of nails etc and grinding where necessary all as specified & directed by Engr-in-Charge. Note:- work will be executed by mechinised means/ tools as required for smart periodical services and work can carried out upto fourth storey. |
| 6 | M&L for preparation old decorated surfaces of walls and cornices spoiled by smoke soot, moulds, moss and efflorescent salts and tradingoil and greasy spots by scraping and washing with water and applying one coat of cement base paint complete all asspecifiedand directed by Engineer-in-Charge.Note:-work can carried out upto fourth storey/hanger |
| 7 | M&L for preparation old decorated surfaces of walls and cornices spoiled by smoke soot, moulds, moss and efflorescent salts and tradingoil and greasy spots by scraping and washing with water and applying two coats of cement base paint complete all asspecifiedand directed by Engineer-in-Charge.Note:-work can carried out upto fourth storey/hanger |
| 8 | M&L for preparation of old decorated surfaces of walls and cornices and applying one coat of acrylic emulsion paint of any colour/pattern upto 4th storey and hanger including necessary scaffoldingall asspecifiedand directed by Engr-in-Charge. |
| 9 | M&L for complete removal of existing treatment includingpreparation of old decorated surfaces of walls and cornices and applying two coats of oil emulsion distemperover one coat ofwhite putty all asspecified and directed by Engineer-in-Charge.Note:- work will be strictly executed by mechinised means/ tools as required for smart periodical services. |
| 10 | M&L for preparation of old painted wooden surfaces of anydescription not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint all asspecifiedand directed by Engineer-in-Charge. |
| 11 | M&L for preparation of old painted steel surfaces of any descriptionnot otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint all asspecifiedand directed by Engineer-in-Charge. Note:- work will be strictly executed by mechinised means/ tools as required for smart periodical services. |
| 12 | M&L for preparation of old painted steel surfaces of any descriptionnot otherwise described, over 10 cm width or girth and applying two coat of synthetic enamel paint all as specified and directed by Engineer-in-Charge. |
| 13 | M&L for complete removal of existing treatment upto plastered surfaces including preparation of old decorated surfaces of walls and cornices and applying two coat of acrylic emulsion paint (Apex) over one coat ofprimer upto 4th storey and hanger including necessary scaffolding Note:- All holes/cracks to be filled with birla putty and making good to old surface) all asspecifiedand directed by Engineer-in-Charge. |
| 14 | M&L for preparation of old aluminium paint steel surface of any description over 10 cm width or girth not otherwise described and applying one coat of aluminium paint, upto any height complete all as specified and directed by Engineer-in-Charge. |
| 15 | Taking down cement or cement lime plasterof any description on bricks wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge |
| 16 | M&L for 15mm thick rendering of ready mix mortar (CM1:4) of approved make for external wall surface mixed with WPC as per manufaccturer instructions finished even & fair as a whole or in patches complete all as specified and directed. |
| 17 | M&L for 10mm thick rendering of ready mix mortar (CM1:6) of approved make for internal wall surface as per manufaccturer instructions finished even & fair as a whole or in patches complete all as specified and directed. |
| 18 | M&L for 5mm thick rendering of ready mix mortar (CM1:4) of approved make for ceiling surface as per manufaccturer instructions finished even & fair as a whole or in patches complete all as specified and directed. |
| 19 | M&L for preparing newly plastered surfaces of walls and applying two coats of cement base paint over a coat of approved primer, complete all as specified and as directed by Engineer-in-Charge. |
| 20 | M&L for preparing new plastered Surfaces of walls and applying two coats of distemper oil emulsion over a Coat of chalk whiting primer, complete all as specified and as directed. by Engineer-in-Charge. Note:- work will be strictly executed by mechinised means/ tools as required for smart periodical services. |
| 21 | M&L for preparation newly plastered surfaces of ceiling and cornices, spoiled by smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots by scraping and washing with water and applying three coats of white complete all asspecifiedand directed by Engineer-in-Charge. Note:- Work can carried out upto fourth storey/hanger |
| 22 | M&L for preparation old decorated stone, concrete, asbestos cement sheet or plaster surfaces of any description not otherwise described, over 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge. Note:- work will be strictly executed by mechinised means/tools as required for smart periodical services. |
| 23 | Supply only liquid water proofing compound complete all as specified and directed by Engr-in-Charge: |
| 24 | M&L for finishing walls with textured paint of required shade of royal play with different tools that added texture to a plain surface as per user requirment including priming coat ofprimer applied @ 2.20kg/10 sqm (Two or more coats applied) as per site rquirment complete all as specified. |
| 25 | S&F in repairs of PVC wall lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and including PVC framework using 35mm wide sheet fillet all as specified. |
| 26 | Dismantling of plain or corrugated steel galvalume sheet/valley gutter of any guage, thickness, including Nainital or similar pattern roof coverings including ridges for north light truss, complete all as specified and directed. |
| 27 | S&F of pre-painted galvalume aluminium zinc coating GI based plain sheet 0.5 mm thick of any colour having tensile strength of 550 Mpa as in valley gutter/cladding to wall and in ridges, fixed with self trapping screws all as specified and directed.Note: All joints to be sealed by silicon sealant to the satisfication of Engr-in -Charge |
| 28 | S&F of Pre-painted Galvalume Aluminium Zinc Coating GI Based trapezoidal ribs sheet 0.5 mm thick in roof as colour bond trapezoidal ribsout of nominal 0.5mm TCT (Total coated thickness) High Tensile steel with minimum 550 MPa yield strength metallic hot dip coated with aluminium-zincally (55% aluminium, 45% zinc) as per IS-1397-Zincalume AZ 150 (Min 150 gms/Sqm total on both side) with super polyster colour bond XRW quality paint coat as per AS/N ZS 2728 including 50x5 mm thick mild steel flat as in wind tie with self tapping screws with PVC washer, complete all as specified and directed by Engineer-in-Charge. |
| 29 | S&FPre-painted Galvalume Aluminium Zinc Coating GI Based trapezoidal ribs sheet 0.5 mm thick as in north light ridges bended, shaped to match the existing pattern of roof ridges out of nominal 0.5mm TCT (Total coated thickness) High Tensile steel with minimum 550 MPa yield strength metallic hot dip coated with aluminium-zincally (55% aluminium, 45% zinc) as per IS-1397-Zincalume AZ 150 (Min 150 gms/Sqm total on both side) with super polyster colour bond XRW quality paint coat as per AS/N ZS 2728 including 50x5 mm thick mild steel flat as in wind tie with self tapping screws with PVC washer, complete all as specified and directed by Engineer-in-Charge. |
| 30 | Taking down/up cast iron rain water pipes 150mm dia and over (including all fittings) with spigot and socket ends and recovering lead complete and cleaning, refixing of above cast iron rain water pipe with spigot and socket ends by using led joint and fixing with suitable size of GI clamp in hanger/high rise building (upto height 20 m) and grouting in cement concrete anongwith anchors bolt/flat iron reqd if anycomplete all as specified and directed by Engineer-in-Charge.Note:-Testing of leak proofjoint also carried out and charges for testing shall be incl in quoted rate. |
| 31 | M&L for cleaning away all grass, vegetation, dry leaves, plant, roots of small plant, from top of vallay gutter and making good/refixing in same position to disturbed pipes/valley gutter/ roof sheets etc. complete all as specified and directed.Note:work will be executed at height 15 m to 20 m. |
| 32 | Dismantling wrought iron or mild steel work/wire febric of any description not otherwise provided for like flat iron bracket for valley gutter, walk way on roof etc, complete all as specified and directed by Engineer-in-Charge |
| 33 | S&F mild steel structural steel work conforming to Fe-410-W (Gde-E-250 quality-A) as in roof trusses (framed), trussed purlins of beam, tee, angle, channel or flat section including distance pieces cleats etc. andcutting to dead ends, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc. also for wedging truing up and fixing complete. |
| 34 | S&F welded steel wire fabric of weight exceeding 4Kg per Sqm welded to steel section at any position complete all as specified and directed by Engineer-in-Charge |
| 35 | S&F mild steel framed brackets of angles tees flat iron square bars etc cut to shape including bending and welding angles as necessary gusset plates reviting, complete all as specified and directed by Engineer-in-Charge |
| 36 | M&L for preparation of new or previously untreated steel & iron surfaces including one coat of red oxide primer over that applying two coats of synthetic enamel paint of any discription over 10cm in width or girth not otherwise described complete all as specified and directed by Engineer-in-Charge |
| 37 | M&L hacking out old broken glasses (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips for north light trusses height upto 15 mtr, complete all as specified and directed. |
| 38 | S&F of 6mm thick solid polycarbonate transparent sheet fixed to metal frame (as in north glass) using aluminium beading, clips screws etc,complete all as specified and directed. |
| 39 | S&F in repairs 150 mm bore cast iron rain water pipes in any length with or without ears with cement joints fixed to walls, complete all as specified and directed by Engineer-in-Charge. |
| 40 | S&F in repairs 150 mm bore CI Bends (any radius) with duck\"s foot or heel rest (ISI marked), complete all as specified and directed by Engineer-in-Charge. |
| 41 | S&F stainless steel (SS-304) wind turbine ventilator of 24\" throat dia size with capacity of 2700 cfm to be mounted on top of a FRP base plate of size 5 1/2\" x 3 1/2\" x 2mm thick with venture dome, including necessary cutting of existing roof sheets, sealing with watertight arrangement, etc., complete all as specified and directed.Technical specifications of fan:- No./M.O.C of fins : 42/S.S. Thickness of fins: 0.50mm M.O.C of Top cover & Mounting Ring S.SInternal fittings (Shaft, Base Frame & Connecting Roads) : G.I. Revolution Mechanism : Double Jet Sealed Ball Bearings or Self Lubricated Nylon Bush |
| 42 | M&L for silicon sealant for joints and junctions after cleaning and making free from dust and drying the surface of valley gutter any girth and description, complete all as specified and directed. |
| 43 | M&L for providing 4mm thick asbestos cement designer building boards including galavanised iron anodized snap grid frame work for false ceiling size of grid 605 x 605mm thickness of section not less than 0.5mm of 3 mm dia GI hanger fixed with steel dash fastner including necessary alternation for fixing electrical fixtures including taking down old false ceiling boards with frame all as specified and directed. |
| 44 | Taking up or down existing 15 mm dia bore steel tubing/PPR pipe and connections including cleaning for refixing or removal to store complete all as specified and as directed. |
| 45 | Taking up or down existing 20 mm dia bore steel tubing/PPR pipe and connections including cleaning for refixing or removal to store complete all as specified and as directed. |
| 46 | Supply, fixing, jointing and testing 15 mm dia bore galvanized iron tube medium grade with all fittings such as bends, elbow, socket, reducer etc and fixed to wall, ceiling or laid in floors complete all as specified and as directed. |
| 47 | Supply, fixing, jointing and testing 20 mm dia bore galvanized iron tube medium grade with all fittings such as bends, elbow, socket, reducer etc and fixed to wall, ceiling or laid in floors complete all as specified and as directed. |
| 48 | S&F in repairs fancy type chromium plated cast copper alloy bib taps long shank & cup 15 mm dia bore complete all as specified and as directed. |
| 49 | S&F in repair 15 mm dia bore stop valve, cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipes or for union and fixed complete all as specified and as directed. |
| 50 | S&F in repairs 500 litre capacity of rotational moulded polyethylene water storage tank includingwith fittings anddismantling of tank complete all as specified and as directed. |
| 51 | S&F in repairs 1000 litre capacity of rotational moulded polyethylene water storage tank includingwith fittings anddismantling of tank complete all as specified and as directed. |
| 52 | M&L for draining out water from existing PVC water storage tank500/1000 ltr capacity and cleaning silt deposited therein, washing out with soap water or surf including taking down connection, float valve and refixing after cleaning complete all as specified and as directed. |
| 53 | M&L 20 mm granite slabincluding 15 mm thick screed bed or bedding layer ofcement mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including making good the edges complete all as specified and as directed. |
| 54 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing, removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 55 | M&L for glazed ceramic colour tile inarea size 450mmx300mm x7mm thick set and jointed in neat cement slurry and pointed in coloured cement on vertical surfaces such as in dado/skirting etc over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and as directed. |
| 56 | M&L for non skid ceramic coloured tiles as inworks, 7 to 8 mm thick(square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 Sqm ( 300 mmx300mm x 7mm thick) set and jointed in neat cement slurry and pointed in colour cement as in floorover and including 15 mm thick screed bed or bedding layer ofcement mortar 1:6 complete all as specified and as directed. |
| 57 | S&F vertified ceramiccoloured tiles of 7 to 8 mm thick (square /rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm in floors, including 15 mm thick screed in CM 1:6 complete all as specified and as directed. |
| 58 | S&F vertified coloured tiles of 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm on vertical surfaces such as skirtings including 10 mm thick rendering etc complete all as specified and as directed. |