| 1 | Labour only for stretching, tightening, fixing and connecting ACSR conductor and GI wire of existing HT/LT overhead line any size and type, between pope to pole, approximate span length 45 to 50 Mtrs complete all as specified and directed for the following conductors :- |
| 2 | 2 Conductors with / without GI wire |
| 3 | 5 Conductors with / without GI wire |
| 4 | 6 Conductors with / without GI wire |
| 5 | Taking down unsv pin type insulator and providing new pin type, porcelain vitreous white brown or green insulator including one galvanized mild steel spindles, two galvanized iron washers and one galvanized iron nut 100mmheight, 65 mm dia for 1100 Volt grade complete all as specified and directed. |
| 6 | M&L for replacement of shackle type porcelain, vitreous white brown or insulator working under 1100 volts grade, pressure of height 75 mm & 90mm diainsulators, dia of bolt 12mm, section of straps 31 x 3mm, washers, nuts complete all as specified and directed |
| 7 | Taking down U/S stay assy and M&L for stay assy comprising of MS stay plate of size 23cmx23cmx6mm thick, stay rod with nuts 215cm ling 20mm dia , MS/GI stay bow 40cm lingh with 2 Nos GI thimbles, galvanized stay wire standard size 7/4mm of suitable length, loop insulation size 65x90mm clearance of hole 16mm & other accessories including excavation earth work & PCC work complete all as per SSR Pt-1 plate No-1 complete all as specified and directed.Note : MS clamps will be measured & paid separately in respected items. |
| 8 | M&L for cleaning away all grass, vegetation, saplings, shrubs, undergrowth, roots and trees up to 50 cm girth from the area surrounding of E/M installations, under HT< over head lines, 4/2 pole structures, transforemer, installations, yards,surrounding valve chamers and removing the rubbish upto a distance 50 mtr outside the periphery of the area under clearance and dressing the area etc complete all as specified and directed. |
| 9 | M&Lin repair for mild steel work as in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot , drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed. |
| 10 | M&L in replacement of cradles, hexagonal/ rectangular fabricated with galvanised steel wire of size 4mm dia complete all as specified and directed. |
| 11 | M&L in repalcement of existing any type or any size aluminium conductor, steel reinforced including binding wire and jumper connect with PG clamp made out of aluminium alloy accodring to IS-617 complete all as specified and directed. |
| 12 | Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for laying of pipes and for poles/stay and struts not exceeding 10 Sqm on plan and getting out, excavated earth, forming bottom surfaces to required level complete all as specified and directed. |
| 13 | Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 3.0 meter in depth for laying of pipes and for poles/stay and struts not exceeding 10 Sqm on plan and getting out, excavated earth, forming bottom surfaces to required level complete all as specified and directed. |
| 14 | Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and directed. |
| 15 | Removing surplus spoil to a distance not exceeding 50 meter and depositing where directed at a level not exc. 1.5 meter above the starting point complete all as specified and directed. |
| 16 | Supply and laying sand river for cushioning with layers of sand 8 cm before lying of cable and 15 cm after lying of cable (total 23 cm) in trenches complete all as specified & directed. (Note: Thickness after punning shall be measured for payment) |
| 17 | Supply and laying brick protection cable cover using sub class ‘B’ brickslaid flat adjacent to each other across the length of cable laid dry complete all as specified and directed. |
| 18 | Supply & Fixing in replacement of existing PCC/Steel pole with new steel tubular poles complete with cast iron base plate, final taper, plug, bolts, nuts & washers as specified type 410 SP-31 (9.0 mtr long)including re-fixing of removed accessoreis such as ACSR/AAC conductor, cables, street light fittings, clamps, nuts & bolts etc complete all as specified and directed. Note :- Excavation, MS work and PCC work will be measured and paid separately. |
| 19 | M&L for PCC work type D-2 (1:4:8) with 40mm graded aggregate for foundation to poles / stays/ strutus or basements etc complete all as specified and directed |
| 20 | M&L for PCC work type C-2 (1:3:6) with 40mm graded aggregate for foundation to poles / stays /strutus etc complete all as specified and directed |
| 21 | M & L for PCC work type B-1 (1:2:4) with 20 mm graded aggregate for coping (new and old damage coping) to poles / stays /strutus etc complete all as specified and directed. |
| 22 | M & L for Horizontal Boring of holes under road, pavement, hard standing by trenchless technology using GI Pipe of required dia and necessary machine suitable for 0.4 mpa working pressure complete all as specified and directed.Note :- GI pipe medium / Light grade will be measeured and paid saperately under respected item. |
| 23 | Supply & Fix in replacement galvanized pipe 100 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed. |
| 24 | Supply & Fix in replacement galvanized pipe 80 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed. |
| 25 | Taking down old rusted galvanized iron pipe including supply & Fix galvanized pipe 40 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed. |
| 26 | Taking down old rusted galvanized iron pipe including supply & Fix galvanized pipe 32mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed. |
| 27 | Supply, laying & testingXLPEinsulatedarmoured heavy duty electric cable with aluminium conductor, 1100V grade, cross sectional area as given below:- |
| 28 | Single core 400 Sqmm |
| 29 | 3.5 core 185 sq.mm. |
| 30 | 3.5 core 150 sq.mm. |
| 31 | 3.5 core 120 sq.mm. |
| 32 | 3.5 core 95 sq.mm. |
| 33 | 3.5 core 70 sq.mm. |
| 34 | 3.5 core 50 sq.mm. |
| 35 | 4 core 35 Sqmm. |
| 36 | 4 core 25 sq.mm |
| 37 | 4 core 16 sq.mm. |
| 38 | 4 core 10 sq.mm. |
| 39 | Supply and fixing in replacement of following accessories installed in existing panel (Indoor/Outdoor) including making in coming / out going electric connections complete all as specified and directed with suitable size of copper wire:- |
| 40 | MCCB rating 250 Amp FP, Breaking capacity 36 kA,including over load and short circuit protection, 415 Volts. |
| 41 | -do- but rating FP 200 Amp, 36 kA |
| 42 | -do- but rating FP 160 Amp, 36 kA |
| 43 | –do- but rating FP 125 Amp, 25 kA |
| 44 | –do- but rating FP 100 Amp, 16 kA |
| 45 | –do- but rating FP 63 Amp, 16 kA |
| 46 | –do- but rating TP 100 Amp , 16kA |
| 47 | MCCB Four pole 630 Amp, 50kA Thermal magnitc adjustable type including over load and short circuit protection, 415 Volts |
| 48 | MCCB Four pole 400 Amp, 36/35kA, Thermal magnitc adjustable type including over load and short circuit protection, 415 Volts |
| 49 | Digital Voltmeter of rating 0-500 V, size 96mm square type |
| 50 | Digital Ammeter of rating upto 0-600 Amp, size 96mm square type |
| 51 | Selector switch rotary type as per existing size and Make. |
| 52 | LED Indicator assy with colour red/ yellow/ blue. (Set of 3) |
| 53 | Current transformer (CT) Copper wound ratio 100/5 Amp (Set of 3 Nos). |
| 54 | –do- but ratio 200/5 Amp. (Set of 3 Nos). |
| 55 | Supply and fixing Onload Change over switch of capacity 400 A, 4 Pole, 415 Vols, 50 Hz, with Panel Mounted rotating handle, including dismantling old unserviceable change over switch by disconnection all incoming and outgoing electrical connection from existing indoor LT Panel complete all as specified and directed. |
| 56 | Ditto- all as per item No- 26 above but of capacity 100 A, 4 Pole, 415 Vols, |
| 57 | Supply and fixing for in replacementofLT 1100 volt Line rigid PVC spacerstype 4 lines complete all as specified and directed. |
| 58 | All as per Item No - 28 above but 3 Line. |
| 59 | All as per Item No - 28 above but 2 Line. |
| 60 | M&L earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level and coveredsurrounded from all sides with mixture of charcoal and common salt in alternate layers upto 15cm above top of plate and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and includingnecessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber (chamber size not less than 300x300x300mm interier diamentions), RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15cm c/c both way for cover and MS frame etc. complete all as specified and directed.NOTE: The unit rate includes earth strip and new GI protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point. |
| 61 | All as per Item No-31 above but Copper electrode 300mmx300mmx3.00 mm thick and copper strip 25mmx3mm thickcomplete all as specified and directed. |
| 62 | M&L in replacement of unserviceable Bus-bar chamber made out of sheet metal enclosure 200 Amps power coated independent for five connections, copper busbar suitable for 200 amps current rating mounted on wall, including disconnecting all incoming and out going electrical connections complete all as specified and directed. |
| 63 | S & F in replacement of unserviceable TPN DB-VTPN for independent mounting fixed/recessed on wall duely flush mounted, 4 way, IP 43, IK 09 with suitable size of copper bus bar complete all as specified and directed. |
| 64 | S & F in replacement of U/S MCB FourPole 32 Amp, 415 Volt, \"c\" curve including necessary connection complete all as specified and directed. |
| 65 | S & F in replacement of U/S MCBSP 6 to 32 Amp, 415 Volt,\"c\" curve including necessary connection complete all as specified and directed. |
| 66 | Material and labour for preparation of old painted surcaces using polish and painting two coats of aluminium paint on exposed surfaces to steel tubular 4 pole structure of 11 mtr including crossarms, Bracket etc including 5 Nos. of strip / bands painted with post office red and nevy blue colour (300 mm each) in alternate layer from coaping, marking of pole number with black synthetic enamel paint 2.5 cm height including in 6\" dia circle complete all as directed. |
| 67 | -ditto- as per item no -37 but LT/HT 2 pole structure |
| 68 | -ditto- as per item no -37 but LT/HT Pole upto 11 mtr (Single pole). |
| 69 | -ditto- as per item no -37 but LT/HT Pole upto 9 mtr (Single pole). |
| 70 | Supply & fix PVC Junction box of size 350x250x150 mm with Aluminium bus bars 04 Nos fixed on pole with the help of MS nuts bolts and MS clamps-2 Nos of size 40mm X5mm thick with one No MCB SP 6 Amp capacity includes making suitable hole on pole to take out connections to fitting if required at site and PVC insulated sheathed multistranded copper conductor 3 core 1.5 Sqmm for making connection from junction box to security light fitting complete including cable glands for incoming and outgoing cables all as specified. |
| 71 | Supply & fix PVC Junction box of size 250x200x105 mm with Aluminium bus bars 02 Nos fixed on pole with the help of MS nuts bolts and MS clamps-1 Nos of size 40mm X5mm thick with one No MCB SP 6 Amp capacity includes making suitable hole onpole to take out connections to fitting if required at site and PVC insulated sheathed multistranded copper conductor 3 core 1.5 Sqmm for making connection from junction box to security light fitting complete including cable glands for incoming and outgoing cables all as specified. |
| 72 | M&L for repairing/servicing calibrating testing and recommissioning ACB, 1.1 KV, out door/indoor type, including replacement of gasket set, adjusting reconditioning stationery moving contact, adujsting link mechanism within limit, nut, bolt and washer including replacement of damage thimbles of required size complete all as directed. |
| 73 | M&L for feeder pillar bus barbox of size of size 600x450x550mm of outdoor type, double door, both side openable, locking arrangement, kiosk type, powder coated, 3.15mm thick MS sheet water proof hinged, having 4 Nos aluminium bus bar of 400 Amp duly colour coded mounted on porcelain insulator, with provn of 06 Nos outgoingsincluding MCCB 200 Amps, 4 pole, 36 kA,= 01 No, LED indicator (RYB), 08 Nos, holes in bottomfor inlet and outlet cablewith suitable size of cable gland and mild steel stand for mounting of panel board made of angle iron of size 50 mm X 50 mm X 6 mm, 1.05 metre high (450mm below ground level and 600mm above ground) along with necessary cement concrete for grouting of panel stand and connecting the panel with earthing complete all as specified and directed by Engineer-in-Charge.Note : (a)Feeder pillar box shall be got fabricated from CPRI approved and shall be from approved list of manufaturer only and depth of panel not less than 55CM.(b)Electric connection between MCCB and Busbar shall be with aluminium strip links duly colour coded.(c)MCCB shall be of make-Havells/Legrand/ABB/C&S(d)PCC for foundation shall be paid in respective item of this schedule. |
| 74 | Supply, Fix and testing end termination jointing kit suitable for 1100V, 16-50 sqmm x 3.5/4 coreXLPE cable heat shrinkable joint complete with jointing material & assessories complete all as specified and directed |
| 75 | Supply, Fix and testing end termination jointing kit suitable for 1100V, 70-120 sqmm x 3.5/4 coreXLPE cable heat shrinkable joint complete with jointing material & assessories complete all as specified and directed |
| 76 | Supply, Fix and testing end termination jointing kit suitable for 1100V, 185-400 sqmm x 3.5/4 coreXLPE cable heat shrinkable joint complete with jointing material & assessories complete all as specified and directed |
| 77 | Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for finding of the cable fault in underground cable and returning filling (including fixing/filling back old bricks and sand) the same after rectification of the cable fault in any type of soil complete all as specified and directed. |
| 78 | M&L for overhauling to outdoor type LT panel / feeder pillar box of any size / make including insulating to bus bars with shrinkable PVC sleeves of colours red, yellow, blue and black repair of worn out / US cables including replacement of door rubber beedings, nuts, bolts washers, hinges, thimbles/lugs, cable glands as [er requirement of site including carry out necessary welding work and make te system functional and testing on load complete all as specified and as directed at site by Engr-in-charge. Note:- Spares required for replacement will be measured & paid separately under respective items. |
| 79 | -do- all as per Srl item No. 49 above but indoor type LT Panel/ feeder box. |
| 80 | M&L for painting to indoor/outdoor type LT panel/FP box of size not more than 1.8 m height internally as well as external surfaces complete with two coats of synthetic enameled paint of approved quality including preparation of old surfaces, writing of bus bars & outgoing /incoming locations with white paint gridth upto 2” (50mm) complete all as specified and directed. |
| 81 | Taking down carefully old unserviceable security light fittings from pole/wall and S & Fin replacement of security light fittings suitable for LED 60 watt with lens including making electrical connection with suitable size of cable complete all as specified and directed |
| 82 | All as per Item No. 52above but of capacity 90 watts with lens including making electrical connection with suitable size of cable complete all as specified and directed |
| 83 | Fabrication, supply, installation, testing and commissioning electrical cubical control panel board (KIOSK TYPE) Double door, CPRI approved an ISO 9001 factory assembled made out door pedestal type feeder pillar box wheather and vermin proof fabricated of 3.0mm CRCA MS sheet of Suitable size,3 phase 4 wire 415 Volt ac 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium strips for incoming/outgoing MCCB\"s including and Mounting measuring instrument such as Volt meter, Ammeter, Selector switchs, CT\"s -03 Set, Phase indicator lamps with holder, toggle switches and MCBs etc including incoming and outgoing cables connections with suitable cable glands and end termination including grouting of feeder pillar box 60 cm above ground level by providing 105 cm long angle iron size 50x50x6mm welded onall four corner embedded in PCC (1:2:4) using 20mm graded upto 45cm complete all as specified and directed. |
| 84 | Feeder piller box shall be consisting the following :-(a)4 Nos electrolytic aluminium bus bars high conductivity aluminium alloy proper insulated of 1 ½ times of the incoming capacity with provision of extension and mounting on porcelain support(b)MCCBFP 400 amps, 50 KA, 415 volts, 50Hz (Adjustable type) = 01 No (Incoming)(c)MCCBFP 160 amps, 25 KA , 415 volts, 50Hz (Thermal magnetic release and overload 80-100%) - 02 Nos (Outgoins) (d)MCCBFP 100 amps, 25KA , 415 volts, 50Hz (Thermal magnetic release and overload 80-100%) - 03 Nos (Outgoins) (e) Digital Panel mounted Amp meter 96 mm square type complete with selector switch complete with suitable size of CT\"s - 01 Set(f) Digital Panel mounted Volt meter 96 mm square type complete with selector switch - 01 Nos (g)Insulated Aluminium bus bars of suitable size shall be provided from the main bus bar to the out going MCCBs.(h)RYB indicating lamp, LED type - 01 sets.(i) Cost of PCC for foundation is deemed to be included in quoted rate by the contractor.(j) Drawing shall be approved by GE before placing the order. |
| 85 | Repairing/ Maint ofLT over head linesand routinemaintenance of electric supply/ currentleakage / Under ground LT cables , servey for vegitation grought over andaround of LT OH lines,Repair / Maintenance of LT feeder piller boxes , incl MCCBs / Timer switch , protection devices . electrical accessories in day to day maintenance and making it serviceable in all respect with all replacement of any major part but including small length of wires (not more than 50cm) adhesive cable and other connected major accessories. Work shall also include to check & removal ofVegitetion etc .Note:-(a)Contractors representative incl 01 x Electrician and 01x Mazdoorwill report to Engr-in-charge/ JE E/M (Ext Elect)daily at forenoon and afternoon to collect routine/urgent works related to Ext Elecctric supplytill completion of contract. The work shall be attended by the contractor immediately. (b) The contractor will ensure availability of manpower equipped with all sort of petty items such as insulation tape, Jumpers , insulators , nuts, bolts, washers etc required to accomplish the job. The contractor will also ensure as availability of every type of requiste T&Pand Mobile phone to his trades man. (c)All routine/urgent jobs recived on job slip will be repaired & got signature of user\"s and will be deposited to JE E/M with in 24hrs. |
| 86 | Supply and spreadinggraded stoneaggregate of size 40 mm atelectrical outdoor installation yard 11/33 KV Substations / Near DP / FP structures etc including leveling of uneven surface, removing vegetation, grass etc complete all as specified and directed. |
| 87 | Supply only PVC electric cable with insulated aluminium conductor (stranded) with inner sheathingof PVC tape and overall PVC sheathed 1100 volts grade, heavy duty, 10 sqmm twin core,weather proof flat with accessories, complete all as specified and directed. |
| 88 | All as per Item No. 57 but of size 2 core 16 Sqmm. |
| 89 | All as per Item No. 57 but of size 2 core 6 Sqmm. |
| 90 | Supply and fixing of cable jointing kit 11 KV (earthed) grade cable for indoor Terminal with long sleeves (Heat shinkable) type joint complete with jointing material and all accessories for 3 core XLPE armouredaluminium conductor cable of size 120 to 185 Sqmm sqmm complete all as specified and directed. |
| 91 | Supply and fixing of cable jointing kit 11 KV (earthed) grade cable for Out door Termination (heat shrinkable) type joint complete with jointing material and all accessories for 3 core XLPE armouredaluminium conductor cable of size 120Sqmm to 185 Sqmm complete all as specified and directed. |
| 92 | All as per Item No - 61 above but of size 3 core 95 Sqmm. |
| 93 | Dismantling of HT/LT steel Poles from its existing location and re-erracting the same in its new location with street light bracket and making electrical connectionincluding Earth work and civil work complete all as specified and directed.Note :- (i) Soil re-filling and compoacting at place of dismanting of existing poles will be done by the contractor and cost of the sanme is deemed to be included in quote rate. |
| 94 | Material and labour in replacement of unserviceable can type resin filled (Alpx3) capacitors with built-in terminal connectors on top and mounting stud on the bottom heavy duty 440 V Un all as per existingtype suitable for APFC panels, 3 phase, 415 V, 50 Hz sysytem of any capapcity. |
| 95 | 25 KVAr |
| 96 | 15 KVAr |
| 97 | 10 KVAr |
| 98 | 5 KVAr |
| 99 | Material and labour in replacement of unserviceable digital power factor controller 4/6 step type with provision of manual and automatic mode operation conforms to IEC 61010-1, high accuracy, IP 41terminals with manual and automatic mode ooperationall as per existing type suitable for APFC panels, 3 phase, 415 V, 50 Hz sysytem of any capapcity complete all as specified and directed. |
| 100 | Material and labour in replacement of unserviceable capacitor switching unitcapcitor duty contactor consisting of mounting block and contactors, for switching capacitors, suitable to be installed directly on 3 pole, 9 to 40 A contactors all as per existing type suitable for APFC panels, 3 phase, 415 V, 50 Hz system of any capapcity complete all as specified and directed.. |
| 101 | Material and labour in replacement of unserviceable capacitor switching unitcapcitor duty contactor consisting of mounting block and contactors, for switching capacitors, suitable to be installed directly on 3 pole, 50 to 65 A contactors all as per existing type suitable for APFC panels, 3 phase, 415 V, 50 Hz system of any capapcity complete all as specified and directed.. |
| 102 | Material and labour in replacement of unserviceable three pole MCB 32 Amp all as per existing make suitable for APFC panels, 3 phase, 415 V, 50 Hz sysytem of any capapcity complete all as specified and directed.. |
| 103 | M & L for prunning of tree branches of any sizes and dia, not less than 2 Mtr around the LT / HT OH line which obstructing the power supply/ maintenance of electric supply as well as street light illumination area including repair of damage broken ACSR conductor, GI wire and jumpers and disposed exc 50 mtr away clearing area and testing of line, complete all as specified and directed.Note : (i) Span length is aproximate 40 to 50m.(ii)Rate quotedare inclusive of repair to damage work in item. |
| 104 | M&L for replacement of unserviceable/ damaged PVC jumper for HT/LT of any size and length to transformer or pole for making connection, complete all as specified and directed. |