| 1 | Taking downChowkhat or frame not exc 1.5 Sqm eachwith shutters (without taking off shutters from the frames) complete all as specified and directed. |
| 2 | Taking downChowkhat or frame not exc 4 Sqm and exc 1.5 eachwith shutters (without taking off shutters from the frames) complete all as specified and directed. |
| 3 | M&L for powder coated aluminium window sliding type (Bombay pattern) with frame of 1.5mm thick aluminium sections including 5.00mm thick tinted glass fixed with & including anodized aluminium snap beading, glazing clips, joining clips, screws, standard rubber gasket, handles/ Knobstwo nos. for each window and MS rollers two nos. for each window shutter etc complete all as specified and directed with following specifications:-(a) Aluminium section for window frame =101.50x44.45x2mm(b) Aluminium section for styles and rails of shutter = 44.0 x18.0x2mm(c) Aluminium ventilator frame with shutters shall be fixed in position in brick wall opening as required according to site conditions including all fastening arrangements etc complete all as specified and directed.Make of aluminium sections:-M/S JINDAL or M/SHINDALCO or M/S INDAL as approved by GE. (d) Aluminium window frame with shutters shall be fixed in position in brick wall opening as required according to site conditions including all fastening arrangements etc complete all as specified and directed.Make of aluminium sections:-M/S JINDAL or M/SHINDALCO or M/S INDAL as approved by GE. |
| 4 | S&FAluminiumanodised powder coatingany colour minimum coating 50 microndoor/ windows/ventilators with one or more rebates including joining cleat for fixing etc complete with frame offixiing with handles, tower bolts, rubber gasketand maruti lock ,complete all as specified and directedetc completeNote :-Floor door spring, sheet glass, wire cloth,etc shall be measured and paid seperately. |
| 5 | M&L for anodised aluminium powder coated door shutters, aluminium section weighting 0.55kg/m ,incl necessary ,5 mm thick, black tinted glass panes with nano coating &glazing or PVC sheet joining with cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, screws, handles, lock , 2 x aluminium handles 150mm, 3 x hinges , 2 x Aluminium tower bolts 150mm with each shutter of any type complete all as specified all as specified. |
| 6 | S&F, in repairs, 20 mm thick, PVC sheet one side prelaminated of approved texture (\"Celuca Ply of Rajshree make or equivalent inas approved by GE) as in Kitchen cabinet complete all as specified and directed. (Note:-Each member i.e. shelf, partition & shutter of kitchen cabinet shall be measured and paid separately) |
| 7 | S&F,18mm thick, plain white PVC sheetsingle side prelam(\"Celuca Ply of Rajshree make or equivalent as approved by GE) as in Shelf partition Kitchen cabinet (with shelves and partitions) including necessary fittings & fixtures as per manufacturer\"s instructions complete all as specified and directed. |
| 8 | Material and labour for repairing of RCC projection, chajjas, facia,bands, shelves, beams, RCC railing, balcony and similar works by dismantling of loose/ disintegrated portion RCC at any height and in any sitution floor (including provn of support,formwork and welding of reinforcement if required with wire mesh of weight 3 kg/ sqm and dubbing/ fillingwith PCC (1:2:4), type B-0, using 12.5 mm graded aggregate,15 to 25 mm thickafter applying cement slurry @ 3 kg/sqm, finished even and smooth to desired shapeand applyingtwo coats of wheater proof emulsion paint to match with existing surfaces complete all as specified and directed. |
| 9 | M & L for10 mm thickStone -12/ Kota Green tiles laid over 15 mm thick screed bed of cm 1:6 as in flooring & riser and jointed with grey cement slurry mixed with pigment to match the shade, rubbing and polishingand incl dismantling / demolition and rubbish off the primisescomplete all as specified and directed. |
| 10 | M&L for 18-20mm thick blackgranitestone (of any type) machine cut, bedded and jointed with gray cement slurry and pointed with white cement with admixture or pigment to match the shade of stone in window cills, jams,cooking platform pillars etc.laid over and including rendering 10mm thick in cement mortar (1:4), jointed with grey cement slurry mixed with pigment to match the shade of the slab includingrounding and rubbing and polishing complete all as specified and directed. |
| 11 | Demolition of cement concrete (un-reinforced) in ground floor and paving n. exc 15 cm thick below or above ground level & dispose off debris upto a distance n. exc. 100 mtrswhere directed complete all as specified and directed. |
| 12 | M&L for 25mm thick cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregate as in sub baseto receive floor finishes complete all as specified and directed. |
| 13 | M&L for Non skid ceramicwooden patternor any colour coloured tiles 7 to 8 mm thick (Square or rectangular) area of each tile exc 0.18 Sqm but not exceeding 0.36 Sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 for laying floor finishesincl dismantling / demolition and rubbish off the primises etc complete all as specified and directed. |
| 14 | M&L for Non skid ceramic wooden pattern or any colour coloured tiles 7 to 8 mm thick (Square or rectangular) area of each tile exc 0.18 Sqm but not exceeding 0.36 Sqm, as in skirting ,dados in vertical surfaces etc and including 10mm thick cement plaster 1:4 incl dismantling / demolition and rubbish off the primises etc complete all as specified and directed. |
| 15 | M&L vetrified Full Body10 mm thick, in(Square/rectangular) polished, area of each tile not exceeding 0.36 sqm, in floors etc. set & jointed in neat cement slurry and pointed in coloured cement to matchincl dismantling / demolition, coloured tiles laid over and including 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specfied and directed. |
| 16 | M&L for VitriefiedFull Bodytiles 10mm thick (square/rectangular) polished area of each tiles not exceeding 0.36 sqmas in vertical surfaces such as dados/skirting etc set and jointedin neat cement slury and in coloured cement to matchincl dismantling / demolition, Coloured on incl plaster (backing coat) 1:4 CM 10mm thick |
| 17 | Material & labour for gypsum board panel 12 mm thick as in ceiling including T section accessory of galvenised mild steel, GIsuspender all as per manufacturer design confirming to IS 2095 and IS 2542 – 1981. Weight of board not less than 7 Kg per Sqm including two coat of Oil bound distemper over a coat of plaster of pariscomplete all as specified and directed. Note: - Rate quoted shall be deemed to be inclusive of gypsum board, frame work and suspender. |
| 18 | S & F in repairvitreous china warecounter ovel wash hand basin, any colour, size 570 x 450 mm sizefixing in slab including fixing waste pipe , CP waste coupling all as specified and approved by Enger-in-Charge |
| 19 | S&Fin repair 450mm long PVC connections with PTMT nuts of suitable for 15mm bore dia pipe complete all as specified and directed. |
| 20 | S & F in repair 15 bore dia chromium plated Stop cock/Angle cockscrewed down high pressure with crutch or butterfly handle & screw both end for iron pipe or for unions complete all as specified and directed. |
| 21 | S& F for in repair swan neck pillar cock chromium plated fancy type screw with iron pipe incl all fittings complete all as specified and directed. |
| 22 | S & F in repair 15 bore dia chromium plated concealed cockscrewed down high pressure with crutch or butterfly handle & screw both end for iron pipe or for unions complete all as specified and directed. |
| 23 | Taking down aluminium/copper point wiring from existing conduit / batten (light, fan, socket or power) complete such as switches, ceiling rose, pendent, regulators, socket, light fittings etc and removing material from site and making good the disturbed surface of wall / floor etc, complete all as specified and directed |
| 24 | M&L for point wiring with 1.5 sqmm (Nominal area ) 1100 Volt PVC Insulated , FRLS unsheathed and multi strandedcopper conductor cable in old PVC Concealed conduitfor one light / fan point or bell point controlled by one switch (including cutting chases and making good the distributed surfaces) and fixing new 3mm thick plastic laminated sheet top cover, sheet screws and 1.6mm thick GI sunken boxes after removing old unserviceable plastic laminated sheeet and sunken boxes included 1.5 Sqmm stranded copper conductor with green PVC Insulation earth contunity conductor connected to common earth dolly etc . complete all as specified and directed Note : The cost ofsunken boxes and bakellite sheet is included in the quoted rate) |
| 25 | Description all as per Srl item No 24.00 above but for one 5 amps socket outlet independent complete all as specified. |
| 26 | Description all as per Srl item No 24.00above but on the same board complete all as specified |
| 27 | Description all as per Srl item No 24.00above but with 2.5 Sq mm size cable multi stranded FRLS copper wire unsheathed for one 3 pin socket outlet 15 Amps on independent board including continuous earth wire of PVC insulated 1.5 Sq mm copper solid conductor connecting to common earth dolly complete. |
| 28 | Supply and fixing in replacement of switch piano type 6 Amps one way 230 volts AC complete all as specified and as directed. |
| 29 | Supply and Fixing in replacement of socket outlet 5 pin, 6 Amps flushtype 230 volts AC complete all as specified and as directed |
| 30 | Supply and Fixing in replacement of switch piano 16 Amps type one way 230 volts AC complete all as specified and as directed |
| 31 | Supply and Fixing in replacement of socket outlet 6 pin 6/16 Amps multi purpose flushtype 230 volts AC complete all as specified and as directed |
| 32 | Supply and fixing in replacementof ceiling rose 65/50 mm two to three terminals complete all as specified. |
| 33 | Supply and fixing in replacement stepped type electronic fan regulator flush type all as specified and directed. |
| 34 | Supply and fixing in replacement of MCB 40 Amps single pole, AC 230 Volts complete all As specified and directed. |
| 35 | Supply and fixing in replacement of MCB 40 Amps single pole with neutral, AC 230 Volts complete all As specified and directed. |
| 36 | Supply and fixing in replacement of MCBs single pole (SP) 5 to 32 Amps with 10 KA breaking capacity of \"B\" series in distribution boards complete all as specifiedand directed. |
| 37 | Supply and fixing sheet metal enclosure for DB’s (Double door type) when MCB’s to be used, single pole and neutral, 8 ways with 200 ampere rated bus bar, 240 volts fixed sunk / flush to the wallwith IP-43 and IK-09 protectioncomplete all as specified and directed by Engineer-in-charge. |
| 38 | Supply and fixing in replacementfor sub main wiring with two run of single core (FRLS) PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area6.0 Sqmm drawing into and including PVC non metallic rigid conduit medium grade of adequate size and making electric connections including one run (FRLS) PVC insulated single core copper conductor cable 6.0 Sqmm as a earth continuity conductor(green colour) and including non metallic medium graderigid PVC conduit, including cutting chases in brick wall,and making good to match the existing specifications complete all as specified and directed by Engineer-in-Charge. Note :- (i)Rates are deemed to be included cutting and making holes in wall/floor for passing in or through conduit (ii)Two run of6.00 sqmm single core (FRLS) PVC insulated copper conductor cable, one run of 6.0 sqmm copper conductor cable (FRLS)as a earth lead and one run of PVC conduit of suitable size will be measured as a one unit. |
| 39 | Material and labour of lamp holder insulated body with 9 Watt LED Bulb,back plate batten/angle type for batten fitting fixed on bakelite sheet 100mmx100mm230V AC cool day light 6500K having maximum height 1020 mm heavy duty complete all as specified. |
| 40 | Supply and fixing of LED T-8 tube light fitting with sinle side connection LED tube rod 18/20 W, 4 Feet made of CRCA sheet steel box type including bipin holder and connection with PVC insulated twin core 23/0.0076 ywisted copper cable from ceiling rode to light fitting complete all as specified and directed. |
| 41 | Supply, laying in trenches or wall and testing in replacement of cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core all as specified and as directed. |
| 42 | M&L for earthing completewith galvanisedsteelearth plateelectrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade)and watering pipe 20 mm bore GI pipe(light grade ) andchamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg.50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PART 1 , with charcoal dust and saltcomplete and earth leadconnected to earthing test point (up to main switche, DBs) completeall as specified &testing on completion. |
| 43 | Excavation in trenches notexceeding 1.5m wide& not exceeding 1.5m in depthand getting out in any type of soil all as specified and as directed. |
| 44 | Returning, filling including spreading, leveling, watering and well ramming in layers not exc 25 cm thick all as specified and directed. |
| 45 | Removal of surplus excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified. |
| 46 | Supply,laying & fixing in replacement double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints, Sockets, Elbows, bends and End caps etc.. allas specified and directed by Engr in Charge ofsize 63mm outer dia and 50 mm inner dia. |
| 47 | Supply and fixing in replacement including taking out old Distribution board of sheet steel enclouser distribution boards, double door factory madeTPN Vertical4 way 3 phase 415 volts 4 way with 200 amps rating copper bus bar and PVC insulatedcopper jumpers of suitable size from the MCCB to the out going circuits oneincoming MCCB and 12 outgoing MCBs circuits comprising of 3 phase 4 wireof suitable rating complete all as spcd and directed with the following accessories :-(a) MCCB 100 amps, 25 KA, FP, 415 volts, 50 Hz = 01 No.(Note:- Out going MCB shall be measured and paid for separately) |
| 48 | Supply and fix in replacement of security light fitting LED 25 Watt withdusk and down sensoraluminum pressure dia cast housing with touched glass cover IP-66 protectionIncludingsuitable sizeand accessories complete mounted including connection with 3 core PVC insulated overall sheathed flexible cable with muyltistranded copper conductor of size not less than 1.0 sq mm from celing rose to fitting terminal including taking down old CFL security light fittingall as specified and as directed. |
| 49 | S& F GI bracket light grade GI Pipe 1.2 mtr Length for fixing of street light fitting36/40 Wattincluding connection all as specified and directed. |
| 50 | M&L forboring of hole under road for passing of electriccable including double wall corrugated (DWC) pipes made of high density polyethylene (HDPE) of of size 75 mm outer dia and 61 mm inner dia complete all as specified and directed. |