| 1 | M&L cement concrete work in pavement/hard standing of flexural strenght 40 kg/Sqcm in field using 400 Kg of cement per cubic metre,thickness of concrete 20 cm including formwork |
| 2 | M &L Forming 20mm thick expansion joints filled with preformed bitumenous filler and top 30mm primed and sealed with sealing compound, grade \"B\", 200 mm thickness complete all as specified and directed. |
| 3 | M&L Forming construction (Dummy) joint for 65mm deep x 10mm wide, filled with sealing compound, Grade-\"B\", complete all as specified and directed. |
| 4 | M&L Finishing surfaces of concrete roads, pavements, by brooming complete all as specified and directed. |
| 5 | Demolition of brickwork or stone/boulders/block masonry, built in cement mortar including all quoins, arches, pillars, ashlar facing, dressed stonework, precast concrete artilcles and precast concrete block walling etc. Complete all as specified and directed. |
| 6 | Taking down cement plaster or terrazzo from brick walls of any description, racking out joints, hacking for key, scrubbing down with water etc complete all as specified. |
| 7 | M&L Squared rubble walling with Porbandar stone masonary in CM 1:6 brought to courses, complete all as specified & directed by Engr-in-charge. |
| 8 | Ditto as above item No. 7.00 but except stone, Complete all as specified and directed. |
| 9 | M & L for Rendering 10mm thick on fair faces of Porbandar stone masonary surface in CM 1:4 all as specified & directed by Engr-in-charge. |
| 10 | M & L for two coats of cement paint over chalk whitening primer over preparing surfaces plastered or unplasteredcomplete all as specified & directed by Engr-in-charge. |
| 11 | M & L Preparation of old plastered surfaces of walls and applying one coats of cement base paint completeall as specified and directed by Engineer in Charge . |
| 12 | M & L Preparation of old treated steel surfaces of any description(Steel gates, Embedded Angles etc), over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified. |
| 13 | M&L for Treatment offloor cracks in existing cement concrete pavements by cutting out portion along the cracks with mechanical equipment into \"V\" shape of 25mm deep, removing the loose material to a distance exc 250m but n exc 1 Km and cleaning the cut out portion with compressed air to remove all foreign materials like dust, dirt, aggregates etc., priming the proposed pot holes with epoxy resin primer and filling with epoxy resin mortar in repair all as specifiedand directed by Engineer-in-Charge. |
| 14 | S & F mild steel round bars 10mm dia, cut to length, hooking ends confirming to Fe-410-W(Gde E-250) quality - A or Fe 290 (Gde - E-165) complete all as spd and directed. |
| 15 | M&L for preparation of oldtreated concrete or plasterd surfaces exc 10cm width or girth and applying one coat epoxypaint (water based) of approved manufacture,completeall as specified and directed by Engr-in Charge. |
| 16 | Demolition of concrete of any description and in any position not otherwise specifically provided for cement concrete (unreinforced) complete including removing debries ouside MD land all as specified and directed. |
| 17 | M&L cement concrete 1:4 :8 type D-2 (40mm graded agg) in foundation filling and mass concrete.complete all as specifed and as directed by Engineer in Charge. |
| 18 | M&L Sand fillingunder paver blocks for cushion Complete all as specified and directed. |
| 19 | M&L Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement pigment to match, Complete all as specified and directed. |
| 20 | Taking down and Repair to steel gate of garrage/entrance etcof size exc 3sqm by taking down and necessary welding work including welding of Hinge, Cleats, MS Plate, MS Sheets etc complete all as specified and as directed by Engineer-In-Charge.Note: Welding work will be carried at site by arrangement of welding machine without any extra cost to the Government. |
| 21 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing),and rubbish off the premisess complete all as specified and as directed |
| 22 | M&L for non-skid ceramic tiles, white/coloured (of approved shade and design), 7 to 8mm thick, of superior quality, square / rectangular (area exceeding 0.06 Sqm but not exceeding 0.11 Sqm) joint free, as in floors, etc.set and jointed in neat cement slurry and pointed in white cement mixed with colouring pigment to match shade of tiles laid over & including 15mm thick screed bed in CM (1:6) complete all as specified and as directed |
| 23 | M&L for coloured Glazed ceramic tiles,of size 300x200x 7 to 8mmthick of superior quality fixed on vertical surfaces such as skirting / dado / risers of step etc.,set and jointed in neatcement slurry and pointed in white cement mixed with pigment to match the colour of tiles fixed over & including backing coat of 10mm thick plaster in CM (1:4) complete all as specified and as directed. |
| 24 | M&L for Light shade vitrified ceramictiles, premium quality, coloured (of approved shade and design), 10mm thick, of superior quality, (square / rectangular) polished, area of each tiles not exceeding 0.36sqm,joint free, as in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles ,laid over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed. |
| 25 | Ditto all as above item No. 24.00 but vertical surfaces such as skirting, dados etcincluding screed bed layer 10mm thick in cement mortar 1:3 finished even and rough for receiving tiles onvertical surfaces complete all as specified. |
| 26 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons, compound walletc.laid dry beded in any mortor complete all as specified. |
| 27 | M&L 20mm thick Granite work in steps, jambs, pillars, window-cills, cooking platforms laid over CM 1:4 , 15mm tk cement screed and jointed with grey cement slurry, and pointed with white cement with admixture ofpigment to match the shade ofgranite stone including grinding and polishing complete all as specified |
| 28 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete |
| 29 | Repair and refixing of aluminium window shutter to make it openable/slide smoothly, including cutting, repair/change of all necessary fittings/fixtures for window like cleates , locking arrangements glazing cleats and cadmium plated stainless steel screws including rubber gaskets beadings etc complete all as specified and as directed by Engr in charge |
| 30 | S&F in repairs Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed |
| 31 | M&L for 15 mm thick rendering in cement mortar 1:6 on stone masonry surfaces or surfaces other than fair faces of brick work, rendering finished even and smooth (without using extra cement)complete all as specified and directed. |
| 32 | M&L for two coats of oil bound distemper over acoat of priming coat on newly prepared wall surfaces,including 3 mm thick layer of wall care putty (Birla white or equivalent)all as specified and directed.. |
| 33 | Disconnecting existing tanks upto 1000 ltr Cap , setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position with Cleaning, repairing, incl complete connection with inlet and outlet with GI / CPVC pipe fitting, Float valve etc Complete all as spd and as directed by Engineer in Charge |
| 34 | S&F in repairs Looking bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified |
| 35 | Taking down chowkats or frames exceeding 1.5sqm but not exceeding 4sqm eachwith shutters (without taking off shutters from the frame) and disposing off complete all as specified |
| 36 | S&F fiber glass reinforced plastic (FRP) door frames of three legged of cross section 90 x 45 mm having single rebate of 32 x 15 mm to receive shutterof 30 mm thick. The laminate door frame moulded with fire retardent grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block of 2nd Class Hardwood in all the three legs. The frame shall be covered with fibre glass from all side M.S stay shall be provided at the bottom to sedy the frame complete as per direction of Engineer - in - Charge. |
| 37 | S&F 30 mm thick glass fiber reinforced plastics paneled door shutter of required colour & approved colour and manufactrures made with fire retardent grade unsaturated polister resin,moulded to 3mm thick FRP laminate for forming hollow rails & styles with wooden frame & suitable blocks of seasoned wood inside at required places for fixing of fittings along with MS tube frame of 19 gauge all around the styles & rails duly coated with steer primer castmonolithically with 5mm thick FRP laminate forpanels& conforming to IS:14856:2000 including fixing to frames. The shade & colour shall be approved by Engineer-in-Charge |
| 38 | S&F 200mm long (Length of Bolt in mm) Aluminium anodised,barrel tower bolts of extruded section and fixed all as specified and directed. |
| 39 | S&F 150mm (Size of Handle in mm) Extruded aluminium alloy handles, fabricated type,anodised all as specified. |
| 40 | S&F 100mm Butt hinges(Size of hinges in mm), medium weight, cold rolled, stainless steel, and fixed all as specified. |
| 41 | Taking down old roof treatment of any description including plaster, cement concrete etc. and removing old material outside MD land exc 1Km and not exceeding 5 Km completely all as specified and directed by Engineer - in - Charge. |
| 42 | M&L for 10 mm thick (average) plastering on concrete surfaces in cement mortar 1:4, in order to maintain proper slope and base over existing roof surfaces for laying of APP based polymeric membrane,add WPC @3% of cement weight(WPC paid separately),finished even and smooth without using extra cement complete all as specified and as directed. (Note:- Polymeric membrane and WPC will be measured and paid separately) |
| 43 | Supply only integral waterproofing compound |
| 44 | M&L for water proofing treatment to RCC roof slab including parapet comprising with the following course of treatment/ specification from bottom to top:- (a) Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces. (b) one layer of APP based polymeric membrane of approved manufacturer, 4 mm thick, weight not less than 3.6 Kgs per Sqm, reinforced with non wovwn polyster fabric or weight not less 160 gms per sqm. Polymeric membrane shall be taken to a height of 60 cm minimum) and then inserted insde the groove of parapet wall and shall be finished by a membrane flashing. (Note:- (i) Laying of APP based membrane shall be done by torch on method or as per manufacturers instruction.(ii) A minimum overlap of 150 mm and 100 mm should be made in the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as manufacturers instruction. (c) Applying two coats of reflective Bituminous aluminium paint on top of APP membrane. |
| 45 | S&F in repairs more rebatesfor aluminium anodised frame and shutters for door, winodows and ventilators or partitions with one or more rebates power coated including jointing cleats for fixing etc complete with power coating any colour minimum thickness 50 micron all as specified and directed. |
| 46 | S&F in repairs aluminium, anodised barrel tower bolts 150 mm long, of extruded section and fixed. |
| 47 | S&F in repairs aluminium handles cast type anodised of size 150mm long. |
| 48 | S&F in repairs butt hinges extruded aluminium alloy with galvanised mild steel hinges pin,anodised and fix 100 mm long. |
| 49 | M&L for glass sheet selected quality 5.5mm thick glazing with clips and aluminium beading area exc 0.5 sqm each pane etc complete all as specified and directed. |
| 50 | M&L for Solid PVC sheet consisting of 5mm thick plain colour sheet including solvent cement and fixing to Aluminium frame etc complete all as specified and directed. |
| 51 | S&F solar control film 25 micron reflective type sticked to glass panes as per manufacturers instruction complete all as specified and directed. |
| 52 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified. |
| 53 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed |
| 54 | Dismantling of plain / corrugated steel sheeting, any gauge, thickness as in roof complete all as specified and directed. |
| 55 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwsall as specified & directed by Engr-in-charge. |
| 56 | M&L Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint overa coat of red oxide primer on steelsurfaces complete all as specified. |