| 1 | S & Fmeter box panel indoor type wall mounted suitable for fixing of 06 Nos of single phase metering unitmade out of CRCA sheet 2mm thick of powder coatedincl power wiring with minimum 10 sqmm PVC insulated FRLSmulti stranded copper conductor and transparent toughenglass of suitable size with following Accessories :-a) MCCB 100 Amp4 pole 16 KA -01 Nos (As incommer)b) Copper busbar of 300 Amp suitable for4 wire system mounted on rubber insulators (Outgoing)(c) MCB 63 Amp SPN -06 Nos(d) MCB SPN 10 Amp-01 Nos (for Staircase)(e) Separate compartment for 6 Nos metering units |
| 2 | S & Fmeter box panel indoor type wall mounted suitable for fixing of 04 Nos of single phase metering unitmade out of CRCA sheet 2mm thick of powder coatedincl power wiring with minimum 10 sqmm PVC insulated FRLSmulti stranded copper conductor and transparent toughen glass of suitable size with following Accessories :-a) MCCB 100 Amp4 pole 16 KA -01 Nos (As incommer)b) Copper busbar of 300 Amp suitable for4 wire system mounted on rubber insulators (Outgoing)(c) MCB 63 Amp SPN -04 Nos(d) MCB SPN 10 Amp-01 Nos (for Staircase)(e) Separate compartment for 4 Nos metering units |
| 3 | Supplying and fixing smart three phase four wire energy meter BIS 16444 : 2015 Reaffirmed 2020) marked in existing meter board/ floor panels having current range 10-60 Amp, 415 Volts, accuracy class 1.0 complete all as specified and directed. |
| 4 | Supplying and fixing smart single phase four wire energymeter BIS 16444 2015 (Reaffirmed 2020) marked in existing meter board/ floor panels having current range 10-60 Amp, 240 Volts , accuracy class 1.0 complete all as specified and directed. |
| 5 | Supply, install, commissioning and testing factory made (including CPRI approved manufacturer) LT panel box (KIOSK) out door type, size not less then size 1500 W x 1500Hx 500 D platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz ACsupply system all as specified and directed having busbar chamber with 4 Nos insulated AL bus bars 600 amps rating installed on porcelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/ volt/Ampsmeter and 50 x 50 x 6 mm thick angle iron for base frame work having angle iron4 Nos each Suitablelong welded to frame/cubical and grouted in ground upto 0.5 Meter by using PCC1:2:4 B2of Suitable sizethe ground over the ground level upto 1 Mtr height . 2 Nos earth terminal to be welded with feeder piller.The complete feeder pillar box should be anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Frontand back opening type for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys reconnecting all existing UG cable with suitable lugs for incoming/outgoing feeders and comprising of all as specified :- (Location :- Near QTr 269 , 280 , 240, 246,293, 288,260 and 263 |
| 6 | Incommer(a) MCCB FP200 A 36 kA with Electronic microprocessor release with over load Zone of adjustment 0.4 to 1.0 In and Electronic release withShort circuit Zone ofadjustment 1.5 to 10.0 Ir. (Adjusted current) with time with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -01 no |
| 7 | (b) 4 Nos Aluminium Bus bars of 400 Amp current rating capacity, of suitable size of length as actually required at site for 3 phase andneutral, mounted on epoxy/FRP bus bar insulator complete with nut bolt fixing arrangement complete- 01 set |
| 8 | Outgoing (c) MCCB FP 100 A 16 kA with Adjustable Thermal release for over load 0.7 to 1.0 and Adjustable magnetic release (10.0 In) forShort circuitwith Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -04 Nos |
| 9 | Metering Compartment |
| 10 | (f) Digital type Amp meter 0-200 Amp(size 96mmx96mm) with Selector switch and3 Nos CT of ratio 250 A/5A-1No |
| 11 | (g) Digital Type volt meter 0-500 V with selector switch -1Nos |
| 12 | (h) Digital Multifunction meter having for measuring KW, KVA KVRa, KWAH, KVAH , Pf, Hz etc-1Nos |
| 13 | (i) RYB LED incating lamp -3 Nos Notes :- (i) Cost of taking out old unserviceable panel is deemed to be included with unit rate of item.(ii) Earth work, PCC baseetc is deemed to be included with unit rate of item.(iii) All MCCB to be installed vertically therefore panel shall be designed accordingly.(iv) Taking OutExisting MCCBsof any Capacity from old LT Panel to be fixed in any other LTPanel Board whereverrequired andrate will be inclusive in this item for fixing or depositing in MESstore Yard. |
| 14 | Excavation in trenches, n. exc 1.5 Mtr wide and n. exc 1.5 Mtr in depth for foundation/laying of cable and getting out in soft/loose soil complete all as specified and directed.. |
| 15 | Removing of excavated soil to a distance n. Exc 50 Mtr and depositing where directed at a level n. Exc 1.5 Mtr above the starting point complete all as specified and directed. |
| 16 | Returning, filling in including spreading, levelling, watering and well ramming in layers n. Exc 25 cm thick complete all as specified and directed.. |
| 17 | Supply & spread unwashed dry river sand for sand cushioning and covering the under ground cable in trenches complete all as specified and directed.(Note :- Punning thickness shall be measured.) |
| 18 | Supplying and laying unreinforced precast concrete cable cover, Type 2, flat, size 300mm x 180mm x 40mm complete all as specified and directed. |
| 19 | Taking out existing unserviceable LT cable any size complete all as specified and directed. |
| 20 | Taking out existing U/S panel/feeder pilar boxfrom existing site including disconnecting of existing cable complete all as specified and directed. |
| 21 | Supply laying testing and comminssioning ofXLPE insulatedLT U/G cable heavy duty , 1100 volts grade, galvanizedwire armoured and PVC sheathed with multistranded aluminium conductor of size4 core16 Sqmm laid in trenches or fixed on wall (including saddle clip) or poles drawn through pipes complete all as specified and directed. |
| 22 | Supply laying testing and comminssioning ofXLPE insulatedLT U/G cable heavy duty , 1100 volts grade, galvanizedwire armoured and PVC sheathed with multistranded aluminium conductor of size4 core25 Sqmm laid in trenches or fixed on wall (including saddle clip) or poles drawn through pipes complete all as specified and directed. |
| 23 | Supply laying testing and comminssioning ofXLPE insulatedLT U/G cable heavy duty , 1100 volts grade, galvanizedwire armoured and PVC sheathed with multistranded aluminium conductor of size4 core35 Sqmm laid in trenches or fixed on wall (including saddle clip) or poles drawn through pipes complete all as specified and directed. |
| 24 | Supply laying testing and comminssioning ofXLPE insulatedLT U/G cable heavy duty , 1100 volts grade, galvanizedwire armoured and PVC sheathed with multistranded aluminium conductor of size4 core50 Sqmm laid in trenches or fixed on wall (including saddle clip) or poles drawn through pipes complete all as specified and directed. |
| 25 | Supply , fixing testing and commissioning of feeder pillar box outdoor made out of CRCA sheet not less than 3.15mm thick duly powder coated, CPRI approved 300 Amp rating Aluminium Busbar boxsize not less than 1 Mtr x1 mtr x .4Mtr suitable for arrengement of following :(a) Incommer :MCCB 100 16 KA 4 pole - 2 Nos (loop in /Loop Out)(b) Out going: MCB SPN 32 Amp - 6 Nos(c) 15 Amp switch socket combination- 6 Nos |
| 26 | M&L Earthing complete with galvanised steel earthelectrode 60 cm x 60 cm x 6 mm burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised earth leadas GI wire of 4 mm dia size by means of bolts,nuts, check nuts and washer etc made of galvanised iron and connected to earthing test point all as shown in electrical plate No.3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation&earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 20 mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed.Note: (i) Rate quoted under this item is deemed to include the cost of 7.5m length of earth lead and its protection tube. Any addition in length shall be measured and paid extra. |
| 27 | M&L Earthing complete with galvanised steel earthelectrode 60 cm x 60 cm x 6 mm burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised earth leadas GI strip of 32X6mm size by means of bolts,nuts, check nuts and washer etc made of galvanised iron and connected to earthing test point all as shown in electrical plate No.3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation&earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 40 mm bore medium grade GI watering pipe, lugs, 40 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed.Note: (i) Rate quoted under this item is deemed to include the cost of 7.5m length of earth lead and its protection tube. Any addition in length shall be measured and paid extra. |