| 1 | Excavation in trenches soft/loosesoil not exceeding 1.5 mtr wide in not exceeding 1.5mtr in depthfor foundation etc or for shaft well, cesspits, manholes, fire hole etc n.exc 10sqmm on plan and not exceeding 1.5mtr in depth and getting out complete all as specified and as directed by the Engr-in-Charge. |
| 2 | Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed by the Engr-in-Charge. |
| 3 | Removing excavated material not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and as directed by the Engr-in-Charge. |
| 4 | M&L for sand cushioning in trenches for protection of LT under ground cable including watering and consolidation complete all as specified and as directed by the Engr-in-Charge. |
| 5 | Supply and laying well burnt sub class ‘B’ bricks, locally available in trenches for protection of underground cable complete all as specified and as directed by the Engr-in-Charge. |
| 6 | M&L in replacement for jointing, testing and commissioning in replacement heat shrinkablestraight through Jointing Kit suitable for LT Cable of size 70 sq mmto 120 Sqmm, 3.5/4 core complete all as specified and as directed by the Engr-in-Charge. |
| 7 | All as per item no 06 but size 25 sq mmto 50 Sqmm, 3.5/4 core complete all as specified and directed by the Engr-in-Charge. |
| 8 | Taking down old UNSV security light fittings from pole upto 11 mtr height, S&Fnew LED street light fitting of capacity 70 watt 6000K,made up of pressure die cast housing with toughned glass and individual high power LEDs, IP66 protection, peanut lens and impact resistance of IK07 with 10KV built in surge protection device having top opening separate driver compartment complete all as specified and as directed by the Engr-in-Charge. |
| 9 | Taking down old UNSV security light fittings from pole upto 11 mtr height, S&Fnew LED street light fitting of capacity 90 watt 6000K,made up of pressure die cast housing with toughned glass and individual high power LEDs , IP66 protection, peanut lens and impact resistance of IK07 with 10KV built in surge protection device having top opening seperate driver compartment complete all as specified and as directed by the Engr-in-Charge. |
| 10 | M&L in replacement of cable XLPE insulated screened PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor offollowing sizes complete all as specified and as directed by the Engr-in-Charge. |
| 11 | 120 sqmm 3.5core |
| 12 | 95 sqmm 3.5core |
| 13 | 70 sqmm 3.5core |
| 14 | 50 sqmm 3.5core |
| 15 | 35 sqmm 3.5core |
| 16 | 16 sqmm 4 core |
| 17 | 10 sqmm 4 core |
| 18 | 10 sqmm 2 core |
| 19 | S&F in repairs of street light TIMER control panel, pole/wall mounting made out of CRCA sheet duly powder coated with locking arrangement, incl internal wiring complete with bypass arrangements and comprising of following :- (or as manufactures recommendation and design). (a) Incomer MCB TPN 63 Amps, 240/410V- 01 Nos (b) Digital timer switch - 01 No (c) Contactor AC 3 rating, 3ph, of capacity 65/100 Amps - 01 No(e)Auxilary change over switch 6 A - 01 No |
| 20 | Supplying and laying in replacement of synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, black in colour complete all as specified and directed by the Engr-in-Charge. |
| 21 | M & L in replacement of PVC flat twin core cable with aluminium conductor of size 10 Sqmm 2 core suitable for 1100 volts power supply complete all as specified and as directed by the Engr-in-Charge. |
| 22 | M & L in replacement of PVC flat twin core cable with copper conductor of size 06 Sqmm 2 core suitable for 1100 volts power supply complete all as specified and as directed by the Engr-in-Charge. |
| 23 | Supply and fixing in replacement copper wirein wiring circuits as per site requirements HRFR-PVC insulated single core 1.5 Sqmm 1100 volts grade multi stranded conductor complete all as specified and as directed by the Engr-in-Charge. |
| 24 | Supply and fixing in replacement copper wirein wiring circuits as per site requirements PVC insulated single core 2.5 Sqmm 1100 volts grade multi stranded conductor complete all as specified and as directed by the Engr-in-Charge. |
| 25 | Taking out by disconnecting/unscrewing all electrical connection of UNSV post top light, M & L including testing of post top of 35 watts capacity suitable for 240 volts, 50 Hz, IP 65 single phase power supply,light, spun aluminium landscape luminaire with high power LEDs as light source complete with all standrard accessories complete all as specified and as directed by the Engr-in-Charge. |
| 26 | Taking out old UNSV landscape light from the existing position and M&L including testing and commissionng of landscape luminaire aluminium cast for diffused lighting with high power LEDs as light source having height 1.0 meter of 25 watts capacity suitable for single phase, 240 volts, 50 Hz, IP 65 power supply complete all as specified and as directed by the Engr-in-Charge.Note- Necessary PCC work and excavation is deemed to be included quoted rates. |
| 27 | Taking out by disconnecting/unscrewing all electrical connection of UNSV flood light, M & L including testing of flood of 60 watts capacity suitable for 240 volts, 50 Hz, IP66 protection,single phase power supply,fabricated with die cast aluminium with high power LEDs as light source complete all as specified and as directed by the Engr-in-Charge. |
| 28 | Taking out by disconnecting/unscrewing all electrical connection of UNSV flood light, S&F of flood of 100 watts capacity suitable for 240 volts, 50 Hz, IP66 protection, single phase power supply,fabricated with die cast aluminium with high power LEDs as light source complete all as specified and as directed by the Engr-in-Charge. |
| 29 | S&F in replacement Energy saving150 Watt envoirmental friendly, long life, exclusive innovative die cast aluminium IP66 flood light in LT polewith high power LEDs as light source, suitable for heighlighting architectural features complete all as specified and as directed by the Engr-in-Charge. |
| 30 | Taking out by disconnecting/unscrewing all electrical connection of UNSV vertical medium bay light, M & L including testing of vertical medium bay light of 100watts capacity suitable for 240 volts, 50 Hz single phase power supply, fabricated with die cast aluminium with high power LEDs as light source, IP-54 complete with complete all as specified and as directed by the Engr-in-Charge. |
| 31 | Taking out old UNSV bus chamber of any rating and M&L for supply and fixing aluminium bus bar chamber current rating 200 amps 4 way type suitable for 415 Volts, 50 Hz AC supply complete making all incoming and outgoing connections complete all as specified and directed by the Engr-in-Charge. |
| 32 | Taking out old UNSV Changeover switch of any rating and S&F ofaluminium bus bar Off-load changeover switch AC 20 having current rating 400 amps 4 pole, 415V AC, in Sheet metal enclosure and side handle complete all as specified and as directed by the Engr-in-Charge. |
| 33 | Taking out old UNSV Changeover switch of any rating and S&F ofaluminium bus bar Off-load changeover switch having current rating 200 amps 4 pole, 415V AC, in Sheet metal enclosure and side handle complete all as specified and as directed by the Engr-in-Charge. |
| 34 | Taking out old UNSV MCB any type and M&L for MCB C series TPN 40-63 amps, 4 pole rating,as per IS 60898-1, 415 volts, 50 Hz, 10 KA, complete all as specified and as directed by the Engr-in-Charge. |
| 35 | Supply and fixing in replacement SPN 32 amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) and current carrying capacity in the MCB DB complete all as specified and as directed by the Engr-in-Charge. |
| 36 | All as per item No. 27.10 above but MCB 40 to 63 Amp complete all as specified and as directed by the Engr-in-Charge. |
| 37 | Supply and fixing in replacement 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB complete all as specified and as directed by the Engr-in-Charge. |
| 38 | All as per item no:28 above but of 40Amps complete all as specified and as directed by the Engr-in-Charge. |
| 39 | M&L for providing cement concrete type D2 (1:2:4) using 40 mm graded stone aggregate in foundation, filling and mass concrete complete including dismantling existing complete all as specified and as directed by the Engr-in-Charge. |
| 40 | S&F in replacement of GI pipe of size 50mm dia, \"light grad\", galvanised, with all fitting, laid in trenche for cable crossing through road & path ways, complete all as specified and as directed by the Engr-in-Charge. |
| 41 | S&F in replacement of GI pipe of size 80mm dia, \"light grad\", galvanised, with all fitting, laid in trenche for cable crossing through road & path ways, complete all as specified and as directed by the Engr-in-Charge. |
| 42 | M&L for Excavation by Trench less Boaring Technology for holes under road, pavement, hard standing using Ultra sound technique and engaging necessary Machine including HDPE pipe ISI marked of upto dia 100 MM suitable for 0.4 MPA working pressure complete all as specified and as directed by the Engr-in-Charge. Note - HDPE pipe and making good the distrubed surface is deemed to be included in rate quoted by the Contractor. |
| 43 | Taking down /dismantling of old UNSV solar street light from the existing location and M&L for servicingand testing, commissioning of solar street light including replacement of unserviceable component like solar street light lamp having luminaire 15 Wattage, LED type, Maximum power poit tracking (MPPT) SCC solar charge controller, Mono Crystalline SPV panel of 30 watts & making them serviceable, complete all as directed by Engr-in-charge. |
| 44 | S&F in replacement of Solar battery, maintenance free, 12V, 65Ah, complete all as specified and as directed by the Engr-in-Charge. |
| 45 | Supplyand fix in replacement of looping box duly disconnecting of incoming/outgoing cables & removing from site, installation and testing of non transparent SMC Kiosk box 3 phase with 4 No bus bar, 63 Amps aluminium 4 wire and 1 nos Kit kat fuse of 10 amps factory made out of 14 gauge steel sheet locking arrangement front side of suitable size 300x200x100 mm complete all as specified and directed by Engr-in-charge. |
| 46 | M&L in replacement for supply, installation and testing in replacement of Earthing complete with galvanised steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected tobut using galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed by the Engr-in-Charge. |
| 47 | S&F in replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required25x4mm galvanised iron stripe, complete all as specified and as directed by the Engr-in-Charge. |
| 48 | M&L in replacement for servicing & testing of ACB 4 Pole, 415 V, with thermal magnetic release (manual fixed type) of capacity 1600 amps, after taking proper shut down complete all as specified and as directed by the Engr-in-Charge.Note: All the components required at is deemed to be included in quoted rate. |
| 49 | Supply & Fixing in replacement ACB 4 Pole, 415 V, with thermal magnetic release (manual fixed type) of capacity 630 amps, suitable for existing LT panelconforms to IS/IEC 60947-2 & IEC 60947-2, high short time fault withstand capacity,Icu=Ics=Iws for 1 sec for total selectivity, pollution degree 4 suitability, break time of 25msec, complete all as specified and as directed by the Engr-in-Charge. |
| 50 | Supply & Fixing in replacement MCCB 400 Amps 4 Pole breaking capacity 36 kA,415 V,suitable for existing LT panel Adjustable type,conforms to IS/IEC 60947-2 & IEC 60947-2, ICS=100 % of ICU with spreader terminals complete all as specified and as directed by the Engr-in-Charge. |
| 51 | All as above item No: 41, but MCCB of 250Amp, 4 pole, 36 kA complete all as specified and as directed by the Engr-in-Charge. |
| 52 | All as above item No: 41, but MCCB of 200Amp, 4 pole, 36 kA complete all as specified and as directed by the Engr-in-Charge. |
| 53 | All as above item No: 41, but MCCB of 125Amp, 3 pole, 16 kA complete all as specified and as directed by the Engr-in-Charge. |
| 54 | All as above item No: 41, but MCCB of 100Amp, 3 pole, 16 kA complete all as specified and as directed by the Engr-in-Charge. |
| 55 | All as above item No: 41, but MCCB of 63Amp, 3 pole, 16 kA complete all as specified and as directed by the Engr-in-Charge. |
| 56 | Supply and fixing in repair ofdigital Voltmeter of range 0-500 Volts single phase, Class 01 of size 96 x 96mm suitable for existing LT panel complete all as specified and as directed by the Engr-in-Charge. |
| 57 | Supply and fixing in repair ofdigital Amp meter with CTs 0-300 Amps single phase, class 01 of size 96 X 96mm suitable for existing LT panel complete all as specified and as directed by the Engr-in-Charge. |
| 58 | S&F in replacement2\"x2\" size LED panel lighting luminaire glare free illumination suitable fr false ceiling (armstrong/Grid) fitting size 600x600x70 mm (LXWXH) of 42 watts capacity recess mounting with high brightness SMD LEDs complete all as specified and as directed by the Engr-in-Charge. |
| 59 | S&F in replacement1\"x1\" size LED panel lighting luminaire glare free illumination fitting size 300x300mm (LXWXH) of 15 watts capacity surface mounting with high brightness SMD LEDs complete all as specified and as directed by the Engr-in-Charge. |
| 60 | S&F in replacement LED bulb 12 watt white/warm white in colour and pin/thread type suitable for B22 base complete all as specified and as directed by the Engr-in-Charge. |
| 61 | S&F in replacement of Modular switch 1 way 6A, 1 module , 230 Volt, flush button single pole one way complete all as specified and as directed by the Engr-in-Charge. |
| 62 | S&F in replacement ofSocket,6A - 2/3 pin combined 2 module230 Volt flush type complete all as specified and as directed by the Engr-in-Charge. |
| 63 | S&F in replacement ofModular switch 1 way 16A, 1 module , 230 Volt, flush button single pole one way complete all as specified and as directed by the Engr-in-Charge. |
| 64 | S&F inreplacement ofSocket6A/16A - 2/3 pin combined 2 module 230 Volt flush type complete all as specified and as directed by the Engr-in-Charge. |
| 65 | S&F in replacement of LED lights fitting 1x 20W, 220V, AC retrofit type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by the Engr-in-Charge. |
| 66 | Dehydration and filtration of the existing transformer/servo voltage stablizeroil by Dehydration plant to achieve di-electric strength of 40 KV at the gap of 4mm complete all as specified and directed by Engineer-in-charge.(Dehydration plant shall be brought at site by the Contractor) and shall also include the following provisions :- a)Testing of transformer /servo voltage stablizer oil before & after dehydration shall be carried out as directed.b) The Unit of Payment under this item shall be per liter of oil meant for all processes to the entire completion of jobs. (c) Contractor will maintain a register of dehydration and filtration of each and every eqpt as per format given by Engr-in-charge and submit the same to Engr-in-charge. |
| 67 | Supply and filling transformer oil for topping up or replacement in different existing transformers outdoor/indoors type of any capacity located and installed at different places and different height complete all as specified and as directed by the Engineer-In-Charge. Note: - Transformer Oil:- The entire quantity of transformer oil shall be procured in one go.The complete material shall be brought at site and then as per requirement oil should be shifted to site.The Purchase Vrs of transfer oil will be verified by AGEpersonally and certificate for the supply of genuine transformer oil shall be kept on record.Cost of this aspect deemed to be included in the quotedrate |
| 68 | Supply and replacement of dehydrating agents (Silca gel) in transformers ofcapacity upto 1000KVA transformer outdoor/indoor type complete all as specified and as directed by the Engr-in-Charge. |
| 69 | Supply and replacement of LT bushing (Brass stud and bolts with porcelian insulator) suitable size to fixed the transformer capacity range 1000 KVA including replacement of gasket , cable glands, etc to make the transformer leak proof complete all as specified and as directed by the Engr-in-Charge. |
| 70 | Supply only ceramic bushing and Gasket onLT side of transformer of 1000 KVA capacity,complete all as specified and as directed by the Engr-in-Charge. |
| 71 | All as per item No: 61 above, but on HT side of transformer of 1000KVAcapacity, complete all as specified and as directed by the Engr-in-Charge. |
| 72 | Supply & fixingin replacement of aluminium lugs of short barrel complete all as specified and as directed by the Engr-in-Charge of follwoing size: |
| 73 | size of 25Sqmm |
| 74 | size of 35Sqmm |
| 75 | size of 50Sqmm |
| 76 | size of 70Sqmm |
| 77 | size of 95Sqmm |
| 78 | size of 120Sqmm |
| 79 | size of 150Sqmm |
| 80 | size of 185Sqmm |
| 81 | size of 240Sqmm |
| 82 | M&L for painting to LT steel tubular poles along with cross arms, clamps, channels,bracing etc complete with machine spray after cleaning and preparation the surfaces, externally with two coats of aluminium paint duly making 30 cm width circular bands of 03 Nos alternatively 1 meter from grund level with blue paint making back ground and writing numbering of poles complete all as specified and as directed by the Engr-in-Charge. |
| 83 | M&L for painting of transformer complete with two coats of synthetic enamel paint of approved colour including removing of all loose paints, oils dust, rust etc including painting/marking of SM No/MES No, capacity etc. for 1000 KVA capacity complete all as specified and as directed by the Engr-in-Charge. |
| 84 | M&L for painting of LT Panel complete with two coats of synthetic enamel paint of approved colour including removing of all loose paints, oils dust, rust etc of any size, complete all as specified and as directed by the Engr-in-Charge. |
| 85 | Taking down old UNSV security light driver from pole fitting upto 11 mtr height and S&F new electronicLEDdriver suitable for fixing in any make 45/60 Watt LED Light Fitting complete all as specified and as directed by the Engr-in-Charge. |
| 86 | S&F in replacement ofbrass battery lugs suitable for solar light battery terminal, complete all as specified and as directed by the Engr-in-Charge. |
| 87 | S&F in replacement ofbracket made of GI pipe light grade 40mm bore bent to shape as required at site for street light fitting 1.2 m in length and fixed on wall/pole including necessary MS clamps, nuts, bolts etc complete all as specified and as directed by the Engr-in-Charge. |
| 88 | Servicing of standby DG Set of capacity upto 62.5 KVA complete including draining out of diesel from tank, cleaningthe fuel tank thoroughlyand refilling the drained out diesel, draining out engine oil from the sump, cleaningthe sump thoroughly and refilling the sump with new engine oil to it’s required level, replacing the fuel filter, lubricating oil filter, Check & clean air cleaner, change air cleaner elements, Check coolant level & make up the same, drain the Fuel filter & water separator, filling the starting batteries with electrolyte/Distilled water to maintain the required specific gravity, replace the u/s brass Connectors for batteries, Cleaning of Battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, changing of V-belts, changing hoses and clips of air cleaner,checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, Checking offuel, oil and water/ coolantlevel etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories asprescribed by the manufacturer and test for Satisfactory running of DG set for two hour at connected. load & record shall be made in respect of RPM , oil pressure, oil temp., Coolant temp. Voltage, frequency , load current ,Battery charging , fuelconsumption etc. as directed by the Engr in charge.Note :-1. Fuel filter, lubericating filter, air filter, distill water, Engine oil, brass connector, hose pipe set will be measured and paid Separately. 2.Coolant for make up will be measured & paid separately 3. DHPP will be issued by dept for testing only. |
| 89 | All as per srl item no.70 but for 82.5 KVA capacity of DG set complete all as specified and directed by Engr-in-charge. |
| 90 | S&F in repair of diesel fuel filter suitable for DG set of capacity upto 82.5 KVA complete all as specified and directed by Engr-in-charge. |
| 91 | S&Fin repair of lubricating filter suitable for DG set of capacity upto 82.5 KVA complete all as specified and directed by Engr-in-charge. |
| 92 | S&Fin repair of air cleaner/ filter suitable for DG set of capacity upto 82.5 KVA complete all as specified and directed by Engr-in-charge. |
| 93 | S&F in repair of brass terminal for batteries all as specified and directed by Engr-in-charge. |
| 94 | S&Fin repair of Hose pipe set suitable for DG set of capacity upto 82.5 KVA complete all as specified and directed by Engr-in-charge. |
| 95 | S&F in replacement of DG set acoustic enclosure door lock/ door hinges suitable for capacity 30 KVA to 82.5 KVA complete all as specified and directed by Engr-in-charge. |
| 96 | Supply and filling lubricating oil 20W40 for DG Sets as per manufacturer\"s recommendation. |
| 97 | Supply and fillingcoolant for Radiator as per manufacturer\"s recommendations. |
| 98 | S&F in replacement of unserviceable water pump assembly rating upto 82.5 KVA DG set all as specified and directed by Engr-in-charge. |
| 99 | Servicing/ Reconditioning of 90/150/180AH battery with change electrolyte,cell and l all connecting element and bettry termina complete all as specified and directed by Engr-in-charge. |
| 100 | Supply and fix in replacement of Engine safety unit (ESU) for DG set of capacity upto 82.5 KVA complete all as specified and directed by Engr-in-charge. |
| 101 | Supply and fix in replacement ofoil sensor including taking down unsv complete all as specified and directed by Engr-in-charge. |
| 102 | Supply and fix in replacement ofunserviceable water line socket for capacity upto 82.5 KVA including taking down unsvcomplete all as specified and directed by Engr-in-charge. |
| 103 | Supply and fixing in replacement of unserviceable Turbo charger kit upto 82.5 KVA DG set complete all as specified and directed by Engr-in-charge. |
| 104 | Servicing of radiator assembly by removing from engine transporting to the workshop and removing the sediments and scales, corrosion etc by means of acid cleaning and high pressure water washing and air cleaning, gas welding / soldering with good quality materiaL for stopping the leakage etc, re-assembling the same with new gaskets and transporting to the site, fixing to the engine with new clips complete as required for upto 82.5 KVA DG Set complete all as specified and directed by Engr-in-charge. |
| 105 | S&F in repair of New digital RPM Meter of DG Set up to 82.5 KVA complete all as specified and directed by Engr-in-charge. |
| 106 | Supply & Fix in replacement of PVC insulated with standard copper conductor cable 2 mtrs length each soldered with 2 Nos gun metal battery terminals suitable for 180 AH 240 volts DC battery. |
| 107 | Supply only distilled water in one litre container complete all as specified and directed by Engr-in-charge. |
| 108 | Supply only sulphuric acid forlead acid battary in one litre container. |
| 109 | M&Lfor servicing of self starter assembly of DG Set 24 volts by disconnecing the self starter from the engine and transport to workshop for carryout servicing by replacing all unserviceable spare parts including pinion, armature, corbon brushes, commutator, field coil, bushes, contacts, copper plates, jumping leads ets and replacing the filled coil and varnishing all as directed and specified by Engr-in-charge. |
| 110 | Dismantling existing fuel injection pump of DG set of capacity from 30 KVA to 82.5 KVA, transporting to work shop and servicing complete including replacement of plunger, spring,nozzle assembly ,calibratingand re-fixing the same and testing the DG Set to the entire satisfaction of Engr-in-charge. |
| 111 | M&L for maintenance of Engine compatible with upto 82.5 KVA DG set after opening/ dismanteling enginge from DG set, transporting to workshop, including replacement of all neccesary burnt spare parts likecylinder head, cylinder head valve, cylinder head seat, cylinder head guide, wall seal, push guide box, front and rear oil seal, cylinder head bolt, washer, valves, valve spring, inlet valve seat insert, exhaust valve seat insert, valve guide, cylinder head reconditioning kit, sealing ring bottom, sealing ring cap, rocker arm adjustment screw, oil metering screw, bush for support, rocker cover, gasket for rocker cover high temperature application, ball bearings, rubber sleeve, fuel pipe, header botto and top etc, required to keep the engine in satisfactorily functional condition with all adjusting timing of fuel supply, cam shaft,crank shaft complete all as specified and directed by Engr-in-charge. |
| 112 | Supply & Fixing in replacement lead acid battery of 12 volts capacity 150 AH complete all as specfified and directed by EIC. |
| 113 | Supply & Fixing in replacement lead acid battery of 12 volts capacity 180 AH complete all as specfified and directed by EIC. |
| 114 | S&F in replacement ofonload changeover 4 pole, 200 Amps, 415 volts including taking down old unsv changeover complete all as specified and directed. |
| 115 | S&F in replacement ofonload changeover 4 pole, 400 Amps, 415 volts including taking down old unsv changeover complete all as specified and directed. |
| 116 | S&F in replacement ofPower contactor 4 pole, 265 Amps, 415 volts including taking down old unsv contactor complete all as specified and directed. |
| 117 | S&F in replacement of battery charger in dg set control panel of capacity 24 VDC 10 AMP including taking down old unsv charger complete all as specified and directed by Engr-in-charger. |
| 118 | S&F in replacement of water pump suitable for upto 82.5 KVA DG set all as directed by Engr in charge |
| 119 | S&F in replacement of injector suitable for upto 82.5 KVA DG set all as directed by Engr in charge |
| 120 | S&F in replacementof radiator suitable for upto 82.5 KVA DG set all as directed by Engr in charge |
| 121 | S&F in replacementof fan suitable for upto 82.5 KVA DG set all as directed by Engr in charge |
| 122 | S&F in replacementof MCCB 1000 Amps 4 Pole breaking capacity complete all as specified and directed by Engr in charge |
| 123 | M&L for HT under ground cable fault finding for exact location by using HT fault locating equipment and trace out the fault complete all as specified and directed.Note :- The rate quoted by the contractor shall include the rate for excavating the cable at the fault location and pinpoint the fault and repairing the cable using cable jointing kits and by adding extra HT cable if required at site, jointing the cable as before to the panel and testing complete all as earth work and necessary T&P etc. |
| 124 | S&F in replacement of cable route indicator made out of 15x15x6mm GI Plate welded with 8mm x 45cm long GI rod routed in PCC block 1:2:4 type B1 using 20mm graded stone aggregate of size 15x15x10cm and writing the word \"HT Cable\" as directed with synthetic enamel paint of two coats over a coats of primer including excavation and earth work all as directed. |