| 1 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying pipes and getting out in soft/loosse soilall as specified and directed by Engr-in-Charge. |
| 2 | Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm all as specified and directed by Engr-in-Charge. |
| 3 | Removing the excavated soil from the trench n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point all as specified and directed by Engr-in-Charge. |
| 4 | Detection and repair of leakage in main water line by necessary excavation in any type of soil, in any situation/depth including bailing out leakage water by suitable measures, repair to CI/DI /HDPE pipe of following sizes by burning & including lead, spun yarn etc as occuring at Site including cutting threading for addition & alternation and for insertion of fittings all as required. Note:- (i) Rate quoted shall be excavation/ filling making good the existing surfaces with the necessary T&P as required all as directed by the Engineer-in-Charge.(ii) Lead joints and jointing fittings shall be measured and paid separately. |
| 5 | 300 mm bore |
| 6 | 200/150 mm bore |
| 7 | 80/100 mm bore |
| 8 | Detection and repair of leakage in water main on walls, floors or in trenches by necessary excavation in any type of soil, in any situation including bailing outleakage water by suitable measures, repair to PVC/GI / HDPE pipes for the following sizes by cutting threading, for addition & alternation and insertion of fittings/accessories (PVC/GI) all as required:-Note:- (i) Pipe fittings shall be measured and paid separately. (ii) Rate quoted shall be excavation/ filling making good the existing surfaces with the necessary T&P as required all as directed by the Engineer-in-Charge. |
| 9 | Upto 20/25mm bore size |
| 10 | 40mm bore size |
| 11 | 50mm bore size |
| 12 | Supply only the following GI fittings for repair the leakage complete all as specified and directed. |
| 13 | Elbow 20 mm bore |
| 14 | Elbow 25 mm bore |
| 15 | Elbow 40 mm bore |
| 16 | Elbow 50 mm bore |
| 17 | Union 20 mm bore |
| 18 | Union 25 mm bore |
| 19 | Union 40 mm bore |
| 20 | Union 50 mm bore |
| 21 | Socket 20 mm bore |
| 22 | Socket 25 mm bore |
| 23 | Socket 40 mm bore |
| 24 | Socket 50 mm bore |
| 25 | Nipple 20 mm bore of length 0.15m |
| 26 | Nipple 25 mm bore of length 0.15m |
| 27 | Nipple 40 mm bore of length 0.15m |
| 28 | Nipple 50 mm bore of length 0.15m |
| 29 | Tee 20X20X20 mm bore |
| 30 | Tee 25X25X25 mm bore |
| 31 | Tee 40X40X40 mm bore |
| 32 | Tee 50X50X50 mm bore |
| 33 | Taking up or down steel tubing and connections, including all fiting 15 mm bore complete all as specified and directed by Engr-in-charge. |
| 34 | Taking up or down steel tubing and connections, including all fiting 20 mm bore complete all as specified and directed by Engr-in-charge. |
| 35 | Taking up or down steel tubing and connections, including all fiting 25 mm bore complete all as specified and directed by Engr-in-charge. |
| 36 | Taking up or down steel tubing and connections, including all fiting 40mm bore complete all as specified and directed by Engr-in-charge. |
| 37 | Taking up or down steel tubing and connections, including all fiting50 mm bore complete all as specified and directed by Engr-in-charge. |
| 38 | Supply and laying steel water Tubing, 15 mm dia ISI Marked, \"Medium grade\" galvanised, including tube fittings Viz Tees Socket elbows, union nipple etc screwed and socketed joint laid in wall and ceiling or laid in floorswith all fitting complete all as specified. |
| 39 | Supply and laying steel water Tubing, 20 mm dia ISI Marked, \"Medium grade\" galvanised, including tube fittings Viz Tees Socket elbows, union nipple etc screwed and socketed joint laid in wall and ceiling or laid in floors with all fitting complete all as specified. |
| 40 | Supply and laying steel water Tubing, 25 mm dia ISI Marked, \"Medium grade\" galvanised, including tube fittings Viz Tees Socket elbows, union nipple etc screwed and socketed joint laid in wall and ceiling or laid in floors trenches/under road with all fitting complete all as specified. |
| 41 | Supply and laying steel water Tubing, 40 mmdia ISI Marked, \"Medium grade\" galvanised, including tube fittings Viz Tees Socket elbows, union nipple etc screwed and socketed joint laid in trenches/under road with all fitting complete all as specified. |
| 42 | Supply and laying steel water Tubing, 50 mmdia ISI Marked, \"Medium grade\" galvanised, including tube fittings Viz Tees Socket elbows, union nipple etc screwed and socketed joint laid in trenches/under road with all fitting complete all as specified. |
| 43 | S& F in replacement of Gun-metal, globe or gate valves with iron wheel head screwed both ends for iron pipe & fixed 15 mm bore of pipe complete all as specified and directed by Engr-in-charge. |
| 44 | S& Fin replacement of Gun-metal, globe or gate valves with iron wheel head screwed both ends for iron pipe & fixed 20 mm bore of pipe complete all as specified and directed by Engr-in-charge. |
| 45 | S& Fin replacement of Gun-metal, globe or gate valves with iron wheel head screwed both ends for iron pipe & fixed 25 mm bore of pipe complete all as specified and directed by Engr-in-charge. |
| 46 | S& Fin replacement of Gun-metal, globe or gate valves with iron wheel head screwed both ends for iron pipe & fixed 40 mm bore of pipe complete all as specified and directed by Engr-in-charge. |
| 47 | S& Fin replacement of Gun-metal, globe or gate valves with iron wheel head screwed both ends for iron pipe & fixed 50 mm bore of pipe complete all as specified and directed by Engr-in-charge. |
| 48 | Supply, laying, jointing, commissioning and testing Cast iron pipes of dia 80 mm with spigot and socket ends centrifugally cast. Class LA, in any length, laid in trenches including takingup old unservicable pipe complete all as specified. |
| 49 | Supply, laying, jointing, commissioning and testing D.I Pressure pipes \"ISI\" marked to IS:8329/2000 of dia 100 mm with socket spigot ends suitable for \"Push-on joint\" in standard working lengths supplied with a rubber gasket (tyton joint)IS 5382/1985 duly \"ISI\" marked for water, class K-7with socket andwith cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe laid in trenches including takingup old unservicable pipe complete all as specified. |
| 50 | Supply, laying, jointing, commissioning and testing D.I Pressure pipes \"ISI\" marked to IS:8329/2000 of dia 150 mm with socket spigot ends suitable for \"Push-on joint\" in standard working lengths supplied with a rubber gasket (tyton joint)IS 5382/1985 duly \"ISI\" marked for water, class K-7with socket andwith cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe laid in trenches including takingup old unservicable pipe complete all as specified. |
| 51 | Supply, laying, jointing, commissioning and testing D.I Pressure pipes \"ISI\" marked to IS:8329/2000 of dia 200 mm with socket spigot ends suitable for \"Push-on joint\" in standard working lengths supplied with a rubber gasket (tyton joint)IS 5382/1985 duly \"ISI\" marked for water, class K-7with socket andwith cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe laid in trenches including takingup old unservicable pipe complete all as specified.Note:- Test Certificate for pipe from manufacturer shall be produced.No payment shall be entertained without test certificate. |
| 52 | Supply, laying, jointing, commissioning and testing D.I Pressure pipes \"ISI\" marked to IS:8329/2000 of dia 300 mm with socket spigot ends suitable for \"Push-on joint\" in standard working lengths supplied with a rubber gasket (tyton joint)IS 5382/1985 duly \"ISI\" marked for water, class K-9with socket andwith cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe laid in trenches including takingup old unservicable pipe complete all as specified.Note:- Test Certificate for pipe from manufacturer shall be produced.No payment shall be entertained without test certificate. |
| 53 | Supply, installation and testing in replacement ofCI/DI Sluice valve flanged Type, class PN 1.6 , 300 mm bore (12\")ISI marked conforming to IS- 14846-2000 complete with gunmetal spindle flanged both ends drilled, CI gate with brass ring and iron wheel handle suitable for CI/DI pipe lineincluding jointing material i.e. nuts bolts, washer and gasketcomplete all as specified. |
| 54 | Supply, installation and testing in replacement ofCI/DI Sluice valve flanged Type, class PN 1.6 , 200 mm bore (8\")ISI marked conforming to IS- 14846-2000 complete with gunmetal spindle flanged both ends drilled, CI gate with brass ring and iron wheel handle suitable for CI/DI pipe lineincluding jointing material i.e. nuts bolts, washer and gasketcomplete all as specified. |
| 55 | Supply, installation and testing in replacement ofCI/DI Sluice valve flanged Type, class PN 1.6 , 150 mm bore (6\")ISI marked conforming to IS- 14846-2000 complete with gunmetal spindle flanged both ends drilled, CI gate with brass ring and iron wheel handle suitable for CI/DI pipe lineincluding jointing material i.e. nuts bolts, washer and gasketcomplete all as specified. |
| 56 | Supply, installation and testingin replacement of CI/DI Sluice valve flanged Type, class PN 1.6 , 100 mm bore (4\")ISI marked conforming to IS- 14846-2000 complete with gunmetal spindle flanged both ends drilled, CI gate with brass ring and iron wheel handle suitable for CI/DI pipe lineincluding jointing material i.e. nuts bolts, washer and gasketcomplete all as specified. |
| 57 | Supply, installation and testingin replacement of CI/DISluice valve flanged Type, class PN 1.6, 80 mm boreISI marked conforming to IS- 14846-2000 complete with gunmetal spindle flanged both ends drilled, CI gate with brass ring and iron wheel handle suitable for CI/DI pipe lineincluding jointing material i.e. nuts bolts, washer and gasketcomplete all as specified. |
| 58 | S&F rubber gasket joints for CI/DI flanged pipes and fittings for following bores of pipes with and including flange packingas suitable for pipe complete all as specified. |
| 59 | 300 mm bore |
| 60 | 200 mm bore |
| 61 | 150mm bore |
| 62 | 100mm bore |
| 63 | 80 mm bore |
| 64 | M & L for plain cement concrete 1:2:4, type B-1, using 20 mm graded stone aggregate as in roof kerbs/coping/bed plates and the likes including weathering slightly rounded or champhered angles with necessary use and waste of formwork for pipe support, finishing even and smooth without using extra cement complete all as specified. |
| 65 | M & L for in replacement MS sheet cover made out of 3mm thick and angle iron frame 40 x 40 x 6 mm around edge duly welded as per existing with locking arrangement and lifting handle including two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 66 | M & L for construction of Valve pit of size 1050mmX1050mmX1050mm(internal dimension) with brick masonry constructed in cement mortar 1:4 including necessary excavation and earth work in soft/loose soil, brick work,plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6 mm, MS sheet cover of 1.6 mm thickfixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock , complete all as specified and directed by Engr -in-Charge. Note : MS Sheet cover shall be paid separately under respective BOQ item. |
| 67 | M & L for construction of Valve pit of size 900mmX900mmX900mm(internal dimension) with brick masonry constructed in cement mortar 1:4 including necessary excavation and earth work in soft/loose soil, brick work,plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6 mm, MS sheet cover of 1.6 mm thickfixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4, type B-1, including handle and locking arrangement with one number 50 mm dia brass pad lock, complete all as specified and directed by Engr -in-Charge. Note : MS Sheet cover shall be paid separately under respective BOQ item. |
| 68 | M & L for construction of Valve pit of size 450mmX450mmX450mm(internal dimension) with brick masonry constructed in cement mortar 1:4 including necessary excavation and earth work in soft/loose soil, brick work,plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6 mm, MS sheet cover of 1.6 mm thickfixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4, type B-1, including handle and locking arrangement with one number 50 mm dia brass pad lock , complete all as specified and directed by Engr -in-Charge. Note : MS Sheet cover shall be paid separately under respective BOQ item. |
| 69 | Cleaning of RCC Overhead reservoir of capacity 2.5 Lakh gallon and at approx 18 mtr to 21.35 mtr staging by scrapping the bottom surface & side walls by brooming with hard wire brush, removal of sludge/mud/silt and other foreign materials from the bottom with the help of buckets & rope manually, brought down to the ground level,preliminary washing properly, thereafterwashing with concentrated bleaching powder solution (10 :1) of water and bleaching powder respectively and disposal of collected sludge/ mud material to a distance exc. 50 mbut not exceeding 100 m from the siteand making water supply system functional. Date of cleaning shall be written with white paint on the black strip approx size 30\" x 25\" all as specified and directed. |
| 70 | All as per Ser item No 38.00 above but RCC Overhead reservoir of capacity 0.75 to 1.0 Lakh gallon complete all as specifiedand directed. |
| 71 | All as per Ser item No 38.00 above but RCC Overhead reservoir of capacity0.50 Lakh galloncomplete all as specifiedand directed. |
| 72 | Cleaning of RCC Under ground sump of capacity 2.5 Lakh Gallon by scrapping the bottom surface & side walls by brooming with hard wire brush, removal of sludge/mud/silt and other foreign materials with the help of buckets etc , dewatering the entire sump and finally washing with concentrated bleaching powder solution (10 :1) of water and bleaching powder respectively and disposal of collected sludge/mud material to a distance exc. 50 m but not exceeding 100 m from the siteand making water supply system functional. Date of cleaning shall be written with white paint on the black strip approx size 30\" x 25\" all as specified and directed. |
| 73 | All as per Ser item No 41.00 above but capacity of under ground sump 3/3.5Lakh gallon complete all as specified and directed. |
| 74 | Removing/cleaning of mud & sludge upto the bottom of raw water receiving basin of size 11.75 x 7.70 x 3.75 m deep including cleaning of weeds, bushes and vegetation etc inside the tank and upto 3 m distance in surrounding area of raw water basin and disposal of the removed silt/soil to a distance not exc 50 m and depositing where directed at a level n exc.1.5 m above the starting point complete all as specified and directed |
| 75 | All as per Ser item No 43.00 above but upto bottom of sludge tank of size 12 m dia x 2.75 m deep complete all as specified and directed. |
| 76 | Removal of mud and sludge from the jack wells including cleaning of internal side of jack well / fluculator with proper cleaning material complete all as specified and directed |
| 77 | Site clearance and surface dressing by cutting and removing of elephant/wild grass (sarkanda) from all around the periphery of raw water reservior and removing from site to a distancenot exc 50 m complete all as specified and directed |
| 78 | Supply and fix in replacement flexible type coupling containing tread inside, of size TC-15completeall as specified and directed |
| 79 | Supply and fix in replacement flexible type coupling containing tread inside, of size TC-17/TC-19completeall as specified and directed |
| 80 | Chemical examination of raw water of the plant at water point No 1 from authorised laboratorycomplete all as specified and directed.Note:- Report to be submitted in triplicate. |
| 81 | Bacteriologicalexamination of clear water of the plant at water point No 1 from authorised laboratorycomplete all as specified and directed. Note:- Report to be submitted in triplicate. |
| 82 | Supply only pig lead in slab form suitable for jointing different sizes of pipe lines complete all as specified and directed. |
| 83 | Supply and fix in replacement CI foot valve (Flanged) 300mm dia confirming to IS 4038 including jointing with rubber fibre board gasket, nut bolts etc completeall as specified and directed. |
| 84 | Supply and fix in replacement CI foot valve (Flanged) 200mm dia confirming to IS 4038 including jointing with rubber fibre board gasket, nut bolts etc completeall as specified and directed. |
| 85 | Supply and fix in replacement CI foot valve (Flanged) 150mm dia confirming to IS 4038 including jointing with rubber fibre board gasket, nut bolts etc completeall as specified and directed. |
| 86 | Supply and fix in replacement CI foot valve (Flanged) 100mm dia confirming to IS 4038 including jointing with rubber fibre board gasket, nut bolts etc completeall as specified and directed. |
| 87 | Supply and fix in replacement CI foot valve (Flanged) 80mm dia confirming to IS 4038 including jointing with rubber fibre board gasket, nut bolts etc completeall as specified and directed. |
| 88 | M&L for preprationof old metallic , treated irregular and curved surfaces of pipes , valves, steel railing , agitators of flocculators including removing existing treatment by scrapping,and painting with two coats of synthetic enamel paint complete all as specified and directed. |
| 89 | Supply only manila rope (Rassa) of different sizes suitable for water supply works complete all as specified and directed.Note : Required size of rope will be provided by contractor during execution of work. |
| 90 | M&L for preparation of existing old painted surface of each Pump- Motor set of following capacitypainted completedwith one coats of primer complete all as directed by Engineer in Charge. |
| 91 | 1 to 5 HP |
| 92 | 7.5 to 15 HP |
| 93 | 30 to 40 HP |
| 94 | 75 to 100 HP |
| 95 | Supply only vinegarsuitable for spraying on grass at water supply installations complete all as specified and directed. |
| 96 | M&L for desilting of clay and muddeposited at the bottom of raw water storage sedimentation tank of size 119 x 48 x 4.6 m deep including removing of weeds, bushes and vegetation etc inside the tank and upto 5 m distance in surronding area of storage tank and disposal of the removed silt / spoil depositing to a distane not exc 50 m where directed at a level n. exc 1.5 m above the starting point complete all as specified and directed.Note : - Dewatering of tank shall be carried out through gravity/ pumping by the contractor at his own arrangement alongwith silt by means of pumping or any other approved means without damaging the surface, floor, walls of storage tank,the cost of which shall be deemed to be included in the quoted unit rate of the item. |
| 97 | S&F gland packing of size 9mm to 13mm to be used for motors, pumps, valves etccomplete all as specified and directed |
| 98 | Repair and servicing of fluculators assembly, oiling, greasing of rotating and fixed arms, replacement of central thrust bearing , slip ring assembly , repair servicing of flocculator shaftincluding MS stirrers and blowers complete all as specified and directed |
| 99 | Supply only grease of good quality suitable and withstand the high temperature during functioning for motor and pump complete all as specified and directed |
| 100 | Supply and fixing Submersible flat copper conductor cable of size 35 sqmm x 3 Core suitable for 75/100 HP motor complete all as specified and directed |
| 101 | Supply & Fixing nut and bolts of different sizes including washers to be used for water supply machinarycomplete all as specified and directed. |
| 102 | Taking proper shut down in writing, disconnecting all the electrical connections, dismantling the motor from the base plate and transporting the same for repairto workshop for rewinding, dismantling the motor/rotor, cutting and removing the old heated up/burnt winding of the Starter/Roter, cleaning the slots,bearing,bushes etc ,rewinding the motor Starter/Roter with super enameled copper winding wire of existingsize , gauge and turns etc including all the insulating materials ie.varnish ,china glass paper,\"F\" class paper, insulating paper etcand transportation back the same after winding , reassembling at original position and testing complete of electric motor 75 HP to 100 HP,3 phase,415 volts,AC supplyall as specified and directed .Note:-(a) The contractor shall return the motor within week’s time after handing over for repairs to contractor otherwise a penalty of Rs. 1000/- per day will be charged from the contractor. (b)The rates quoted shall be deemed to include the cost of loading/unloading, transportation, nuts bolts and washers of any size and shape as required at siteand refixing of serviceable motor duly functional and testing complete at its existing location/position complete all as specified and directed. (c)The contractor shall arrange a visit ofEngr-in-Charge to workshop for each job and cutting of complete burnt winding of motor shall be completed in presence of Engr-in-Charge. |
| 103 | All as per Ser item No 67.00 above but of capacity 30 to 45 HP, 3 phase 415 volts AC supply complete all as specified and directed. |
| 104 | All as per Ser item No 67.00 above but of capacity 10 to 20 HP, 3 phase 415 volts AC supply complete all as specified and directed. |
| 105 | All as per Ser item No 67.00 above but of capacity 3 to 5 HP, 3 phase 415 volts AC supply complete all as specified and directed. |
| 106 | All as per Ser item No 67.00 above but in before but of capacity 1 to 2 HP, 3 phase 415 volts AC supply complete all as specified and directed. |
| 107 | M&L disconnecting/dismantling, strip openingand overhauling of pumping set of any make and capacity of 75/100 HP, taking out bearing, bushes, impeller and coupling plates etc and greasing of bearings with superior quality and replacement of brass bushes,tyre coupling, slip, impeller grinding, bearing, shaft, gland bush rusted nut bolts and washer,seal etc and lath work on shaft including proper alignment and re-assembling,installing at original position andtestingto the entire satisfaction of Engineer-in-Charge complete all as specified and directed . |
| 108 | All as per Ser item No 72.00 above but of capacity 30 to 45 HP,complete all as specified and directed by Engineer in Charge. |
| 109 | All as per Ser item No 72.00 above but of capacity 10 to 15 HP,complete all as specified and directed by Engineer in Charge. |
| 110 | All as per Ser item No 72.00 above but of capacity 5 to 10 HP,complete all as specified and directed by Engineer in Charge. |
| 111 | S&F in repair Star Delta Starter, fully automatic, suitable for 15 HP, 415 volts complete all as specified and directed. |
| 112 | S&F in repair Star Delta Starter,fully automatic, suitable for 30 HP, 415 volts complete all as specified and directed. |
| 113 | S&F in repair Star Delta Starter, fully automatic, suitable for 50 HP, 415 volts complete all as specified and directed. |
| 114 | S&F in repair Star Delta Starter ,fully automatic, suitable for 125 HP, 415 volts complete all as specified and directed. |
| 115 | Dismantling existing lead joint of 80 mm bore pipe and providing new run lead joint using old retrieved lead & additional lead, if reqd at site complete all as specified and directed. |
| 116 | Dismantling existing lead joint of 100/150 mm bore pipe and providing new run lead joint using old retrieved lead & additional lead, if reqd at site complete all as specified and directed. |
| 117 | Dismantling existing lead joint of 200/300 mm bore pipe and providing new run lead joint using old retrieved lead & additional lead, if reqd at site complete all as specified and directed. |
| 118 | Material and labour for replacement for motor pump foundation including angle iron frame, breaking existing PCC foundation new PCC foundation grouding nut bolt complete all as specified and as directed. |
| 119 | Supply and laying HDPE pipe PN 10 (ISI marked)including all fitting laid in trenches/ fixed to wall/ fixed on pillars complete all as specified and as directed of following sizes :- |
| 120 | 80/75 mm dia |
| 121 | 100 mm dia |
| 122 | 50 mm dia |
| 123 | Supply and fix in repair of DOL starter of following capacity all as directed by engineer-in-charge. |
| 124 | 7.5 HP Motor |
| 125 | 3 HP Motor |
| 126 | S&F in repair of contactor 3/4 pole with AC coil 415 volt 50 Hz, suitablefor 100/125 HP motor starter includingservicing wiring and all connection complete all as specified and directed. |
| 127 | S&F in repair of contactor 3/4 pole with AC coil 415 volt 50 Hz, suitablefor 30/40 HP motor starter includingservicing wiring and all connection complete all as specified and directed. |
| 128 | S&F in repair of contactor 3/4 pole with AC coil 415 volt 50 Hz, suitablefor 10/15 HP motor starter includingservicing wiring and all connection complete all as specified and directed. |
| 129 | S&F in repair of contactor 3/4 pole with AC coil 415 volt 50 Hz, suitablefor 1up to 7.5 HP motor starter includingservicing wiring and all connection complete all as specified and directed. |
| 130 | supply and fixing, testing and commissioning ofdigital typewater level indicator system to indicate minimum five level of water with LED\"s and alarm at 100% level of water in RCC Overhead reservoirat approx 18 mtr to 21 mtr height and UG sump including wiring from level sensor inside over head tank or UG sump to display panel on ground level up to 20 meter as required at site all connection complete all as specified and directed. |
| 131 | S & F in replacement 80 mm bore cast iron air release valves, flanged type with two air out lets and including jointing materials such as nuts, bolts, washers and rubber sheet etc complete all as specified and directed by Engr-in-charge. |
| 132 | Supply and fixingCI/DI fitting up to 300mm bore pipe line for reducing/bend (any type radius and angle )taper any type straight,bend increasing decreasing or double socketed extra Tee pieces single branch Y junction double branch cross (all socketed or socket and spigot) collers ,cap and Plugs etc complete all as specified and as directed. |
| 133 | Taking down and disconnecting all the electrical connections, dismantling themotor of any capacity(Air Blower motor) 3 Phase, 415 volts, from the base plate and pump and transporting the same for repairto workshop, dismantling and strip opening of worn out/ defective motor, taking out burnt stator winding, servicing, cleaning of stator slots, bearing, bushes etc, rewinding of stator coils with superior quality copper enamelled wire of existingsize and specificationincluding insulatingmaterial,varnishing andand drying andre-assembling , repair of PCC foundation with grouting of bolts in PCC & iron frame,installation, testing and connected at original location,making electric onnection and applying two coat of synthetic enamel paint complete complete all as specified and directed.Note :-(1) Charges ofloading & unloading, transportation, change of unserviceable nut & bolts and necessary concrete work shall be deemed to be included in the quoted rate. |