}

Tender For Provision Of Deficient Married Accommodation At Af Sulur (Phase-I), sulur-Tamil Nadu

Military Engineer Services has published Tender For Provision Of Deficient Married Accommodation At Af Sulur (Phase-I). Submission Date for this Tender is 21-09-2024. Pump House Construction Tenders in sulur Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

44064734
Corrigendum : Tender For Provision Of Deficient Married Accommodation At Af Sulur (Phase-I)
Open Tender
Indian
Tamil Nadu
Sulur
21-09-2024

Tender Details

Tender For Provision Of Deficient Married Accommodation At Af Sulur (Phase-I); 2 GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to XIV are prepriced by MES under Ser No. 1 to 8. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. 3 Lumpsum price worked out by the contractor for “Building or works” as listed in Schedule ‘A’Part–I 4 Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’Part–II 5 Lumpsum price worked out by the contractor for “Internal Electric Supply as listed in Schedule ‘A’Part–III 6 Lumpsum price worked out by the contractor for “Site clearance and development as listed in Schedule ‘A’ Part IV . 7 Lumpsum price worked out by the contractor for Road/Path/culvert as listed in Schedule ‘A’ Part V . 8 Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part – VI. 9 Lumpsum price worked out by the contractor for “Area Drainage” as listed in Schedule ‘A’ Part – VII. 10 Lumpsum price worked out by the contractor for “External Water supply (E/M)” as listed in Schedule ‘A’ Part – VIII. 11 Lumpsum price worked out by the contractor for “External ElectricSupply ” as listed in Schedule ‘A’ Part – IX. 12 Lumpsum price worked out by the contractor for “D G SET” as listed in Schedule ‘A’ Part – X. 13 Lumpsum price worked out by the contractor for “Fire fighting ” as listed in Schedule ‘A’ Part – XI. 14 Lumpsum price worked out by the contractor for “LIFT” as listed in Schedule ‘A’ Part – XII. 15 Lumpsum price worked out by the contractor for “Lighting Protection” as listed in Schedule ‘A’ Part – XIII. 16 Lumpsum price worked out by the contractor for “Aviation Obstruction Light” as listed in Schedule ‘A’ Part – XIV. 17 Sch A Part - IA : BUILDINGS OR WORKSDesign and Construction of Md Accn for Sergeant /Cpl including covered GF stilt parkingin 7 storey (Ground+6 storey) with using3D monolithic Precastmodular Technology in RCC M-25 or higher Design mix with precastpanel walls and Cast in Situ foundation withATT, PU based WPT, earthquake resistance as per latest IS,UPVC window and Green building norms with GRIHA three star rating etc complete all as specified and as shown on drawings. (Note: The quoted rate against is deemed to included for the provisions contained in Sch A Notes. Refer Sch A Notes complete before quoting these items. Structural design and structural drawings for super structure and foundations for the building/structure shall be prepared to comply with the provisions for design and analysis of RCC structures as per latest editions relevant IS Codes). 18 Design and Construction of Pump house,RCC M-25 or higher Design mix,ATT, PU based WPT, earthquake resistance as per latest IS, UPVC window and Green building norms with GRIHA three star rating etc complete all as specified and as shown on drawings. (Note: The quoted rate against is deemed to included for the provisions contained in Sch A Notes. Refer Sch A Notes complete before quoting these items. Structural design and structural drawings for super structure and foundations for the building/structure shall be prepared to comply with the provisions for design and analysis of RCC structures as per latest editions relevant IS Codes). 19 Sch A Part - XV : Fittings / Fixtures & Misc items. INTERNAL WATER SUPPLYS&F 15 mm bore kitchen sink tap, brass chromium plated dual flow pattern with silicon black flexible hose swivel type complete all as specified and as directed. 20 S&F 15 mm bore washing machine tap, brass chromium plated complete all as specified and as directed. 21 INTERNAL ELECTRIC SUPPLY Supply and Fixing Surface mounted square panel light fiting 1ftx1ftof 18W,220Volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers suitable for roof ceiling in and including connecting up with three core flexible copper conductor cable of suitable size and connected accessorie etc. complete in allas specified and as directed . 22 S&F TPN vertical Distribution board 8 Way, Protection class IP-43 Double door suitable for incomer MCCB suitable upto 160 Amps and outgoing MCB TPN/SP MCB with minimum 200 Amps rating bus bar etc. complete in all respects all as specified and as directed . 23 S&F TPN vertical Distribution board 4 Way, Protection class IP-43 Double door suitable for incomer MCCB suitable upto 160 Amps and outgoing MCB TPN/SP MCB with min 200 Amps rating bus bar etc. complete in all respects all as specified and as directed . 24 Supply and fixing MCCB 4 Pole, 415 Volts, Adjjustable Thermal & Fixed magentic type 100Amps wiht breaking cpacity 16 KA etc. complete in all respects all as specified and as directed. 25 Supply and fixing MCCB 4 Pole, 415 Volts, Adjjustable Thermal & Fixed magentic type 63 Amps wiht breaking capacity 16 KA etc. complete in all respects all as specified and as directed . 26 Supply and fix Modular TV Socket, one module etc complete in all respect all as specified and as directed . 27 M&L TV Wiring with unarmoured co-axial cable,RG-11 in and including concealedwith PVC Conduit 25 mm diaetc complete in all respect all as specified and as directed. 28 EXTERNAL WATER SUPPLY/ EXTERNAL ELECTRIC SUPPLY.(a) Cutting cast iron and reducing to required length before laying pipes in position for insertion of new tees,branches of different sizes as per site requirement for 150 mm bore complete all as directed. 29 Supply and layingductile Iron pipe , S/S including specials, Class “K-7” ,100 mm dia complete all as specified and as directed. 30 Supply and fixNon return valve 80 mm dia complete all as specified and as directed. 31 Supply and fixCI foot valve 80 mm dia to suction line of exisiting pumping set with bolts, nuts, rubber packings, etc complete all as specified and directed. 32 Construction of valve chamber with inner clear dimension 600 x 600 x 900mm suitable for 80mm sluice Valves with PCC (1:4:8) 150mm thick type D2 for foundation, Brick masonary 230mm wall in CM (1:4), PCC (1:2:4) 75mm type B1 for coping, rendering in CM (1:4) 15mm thick including provisiion of 3mm thick MS sheet cover and 25 x 25 x 3mm angle frame embeded in coping with two coats of synthetic enamel paint over a coat of redoxide primer with locking arrangements including necessary earth work complete all as specified and directed . 33 M&L for DI fitting bend (any type, radius and angle) tapers tapers any type (straight, bend, increasing, decreasing or double socket), Tee piece , connection pieces, collers, caps and plug etc complete all as specified and directed. 34 Supply and installation of Booster pumps for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz 30m head, 900 LPM discharge & 3.5 KG/CM2 all as directed. 35 Supply, laying & testing of PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 4 sq mm ,3 core, 1100 Volts grade complete all as specifiedand as directed. 36 S&F LT panel outdoortype made out of MSsheet 2 mm thick with locking arrangement and painting within and including followingasseccories suitable for incoming / outgoing arrangements:-(a)MCCB 100 AMP 25KA4 pole- 01 No(b)DOL startersuitable for 5 HP, 415 V AC- 01 No (c) MCB TPN 40 A - 03 Nos(d)MCB SPN 6-32 AMP, 10 KA- 02 Nos(e)DOL startersuitable for 10 HP, 415 V AC - 02 No(e)Aluminium bus bar200 Amp TPN- 01 Set(f)LCD multi function meter - 01 No(g) Indicating lamp set -01 Set of three(h)CT of suitableratio100/5 A - Set of 3 Nos 37 M&L Earthing with GalvanisedEarth Plate Electrode 600 x 600x 3mm thick burried directlyin Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 32x6mm (upto 7.5m length) by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt,in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete (1:3:6)using 20mm graded crushed stone aggregate and Pre-cast RCC Cover Slab of size 350 x 350 x 50 mm in Cement Concrete (1:2:4) using 20mm gradedcrushed stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as specified and as directed. 38 M&L Earthing with Galvanised Earth Plate Electrode 600x600x 3mm thick burried directlyin Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth wire of 4 mm (upto 7.5m length) by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt,in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed. 39 Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as specified and directed.( Note :- In case sufficient sand not obtained from excavation, the quoted rate is deemed to be inclusive for the required additional qty obtain from out side MD land as directed .) 40 M & L for Protection to cable with one layer of Fly ash bricks of size 23 x 10 x 10 cm laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable complete all as specified and as directed. 41 Supply and fixing 11KV,3 phase 20KA/3sec, 50Hz totally gas insulated OUTDOOR SAFEPLUS compact ring main unit (Type:CCV+) consisting of 2 nos manual operated, fixed type (non draw out type) 630 A load break switches as incomers and 1 No manual operated fixed type (nondraw out type) 630 A vaccum circuit breaker as out going complete in a 2.5mm/ more robotically welded stainless steel tank of IP 67/ more class of protection with 350 MVA rupturing capacity, overload & earth fault protection by 350 MVA rupturing capacity, overload & earth fault protection by self tank powered relays (ASHIDA make ADR 1415/ABB make REJ 603/ or its equivalent. The panel should be with ring core as per the transformer rating 2.5 VA class 5P10 ) all as specified and as directed. 42 Shifting, installation and testing of copper wound transformerstep down, outdoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS:2026 of capacity upto 200 KVA from existing site to prop site (Appx 3 KM around) complete all as specified and directed. 43 M & L for Making of platform including masonary work for transformater of size of 2.00 M x 2.00 M x 2.00 Mtr including fencing complete all as specfied and as directed. 44 Supply, Install, and commissioning LT feeder pillar(CPRI approved) Outdoor typeIP-65 made out of 3.15 mm thick MS sheet and angle Iron frame work, cubicle type with copper bus bars and with suitable mounting plate, frame and canopy, confirms to IEC61439-2 with following accessories suitable for incoming/outgoing arrangements:- (a)MCCB with extended rotary handle and spreader link 320 A 35kA4 pole - 01 No(b)MCCB with rotary handle and spreder link 160 AMP 25kA4 pole - 01 No(c) MCCB with rotary handle and spreder link 125 AMP 25kA4 pole- 01 No (d)MCCB with rotary handle and spreder link 40 AMP 25kA4 pole- 01 No (e) Digital panel meter for voltAmp/Volt/KWH&PF- 01 No(f) LED indicating lamp set- 01 Set of three (g)Timer Switch 20 Amps (h) Channel size 70x40x6MM suitable for LT Panel Load (j) PCC foundation as per OEM drg. complete all as specified and as directed. 45 M & L for GI bracket suitable for street light fittings bend to required shape made up of dia GI tubing 40mm dia medium grade of length 1.50 Mtr including clamps nuts bolts washers complete all as specified and directed. 46 Supply and fix Synchronising electronic timer unit operated on AC 230 Volts, 24 hrs clock time for controling street lights/ flood lights etc all as directed.(Make :-Cat Part No : 4126 41 of Legrand or equivalent in L&T, ABB as approved by GE) 47 Supply and fix Powercontactors 63 Amps, 4 pole,415V etc all as directed .( Make : Cat No 4125 57 of Legrand or equivalent of L&T/ Siemans as approved by GE) 48 M & L for sheet metal enclosure dust, weather and vermin proof rain guarded cable entry and exist arrangement front side hinged door with closing arrangement SMC junction box of size 300 x 200 x 105mm complete all as specified and as directed.( Make : Sintex/Henson or equivalent as given in approved list of make in PS) 49 M & L for 02 Nos single core copper conductor PVCunarmoured cable of size 2.5 sqmm and 01 No. copper conductor cable of size 1.5 sqmm for earth. 1100 Volts grade PVC insulated and PVC sheathed cable through wall/ pole etc including PVC conduit of 20 mm dia appx length 08 mtrs complete all as specified and as directed.(Note:- 1 RM of 2 nos single core 2.5 sqmm copper coductor and 1 RMof1 no 1.5 sqmm copper conductor cable shall be considered as one unit for one RM). 50 DG SETSupply, installation,testing and commissioningof silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation etc. of capacity upto 40 KVA. complete all as specified and as directed. 51 Supply, installation, commissioning and testingof Stainless steel Retro-fit Emission control equipment able to capture specified particulate matter (PM 2.5) emitted from 40 KVA stand by DG with capturing efficiency of minimum 90% and hold 5.5 kibipascal backpressure excerted by DG sets, with min operating Temperature (-)15 Deg celsius, Max operating Temperature 750 Deg Celsius, Operating Humidity up to 90% (Non - Condensing) corrsion resistive construction complete all as specified and directed. 52 FIRE FIGHTINGS&F Clean Agent based stand alone automated Fire Suppression system HCFC123-10 KG complete all as specified and as directed.( Make- Ceasefire/Model No.CF000771 or equivalent as approved by GE) 53 Supply, laying,testing and commissioningTerace Pumping sets, centrifugal, electric driven, supply and Install complete capacity of 900 LPM and 3.5 KG/CM2inclusive of starter and suitablePCC foundation complete all as specified and as directed. 54 Supply and install testing and commissioning of yard hydrant consisting of the following components complete all as specified and as directed:-(a) 63 mm dia instantaneous pattern oblique hydrant with chain cap(b) 63 mm dia size controlled peculation hose of 2 Nos 15 mtr with gun metel female instaneous coupling as necessary.(c ) Sheet steel fabricated hose cabinet of suitable size power coat painted to house the above accessories.(d) one set of branch pipe made of gun metal. 55 Supply and laying ofPVC insulated PVC sheathed wire armoured with multi stranded copper conductor of size 4 Sqmm 4 core 1100 volts grade complete all as specified and as directed. 56 Supplyonly Dry Chemical Powder (ABC) 4 KG complete all as specified. 57 Supplyonly Light weight squeeze grip type type CO2 Type Extinguisher (IS: 15683) - 3 Kg capacity omplete all as specified. 58 SupplyonlyFire Extinguisher water (Stored pressure type) 9 Ltr capacity omplete all as specified. 59 Supplyonly Dry chemical powder extinguisher 9 kg omplete all as specified. 60 SupplyonlyLight weight squeeze grip type type CO2 Type Extinguisher (IS: 15683) - 4.5 Kg capacity omplete all as specified. 61 Supplyonly Mechanical foam type Fire Extinguisher (IS: 15683) - 9 Ltrs capacity omplete all as specified. 62 Supplyand fixingFire Buckets-02 Nos (IS: 2546) including fire point made of PCC bed, MS pipe of 40mm dia, CGI sheet etc.as specified and as directed. 63 LIFTSupply and fix 4 Pole MCCB63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and as directed. 64 LIGHTINING PROTECTIONSupply and fix epoxy base insulators of suitable size 40mm height for fixing GI earth strip on wall/ceiling/floor/poles etc complete all as specified and as directed. 65 AVIATON OBSTRUCTION LIGHTSupply and fix aviation obstruction light LED type comprising of aluminium housing with polycarbonate enclosure complete all as specified and as directed. (Make Bajaj Cat No. BGAV 302 LED or equivalent as given in PS and as approved by GE) 66 S&F DP MCB 6 A with enclosure complete all as specified and as directed. 67 Supply and fix time switches 250 V single Phase of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and as directed.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 06-09-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-09-2024
2 13-09-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-09-2024
3 18-09-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-09-2024
4 30-08-2024 Due Date Extended for tenders closing on 09-08-2024 Admin Corrigendum Date Extend 06-09-2024

Key Value

Document Fees
INR 3000 /-
EMD
INR 1038500.0 /-
Tender Value
INR 14.27 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail