| 1 | Taking down existing street light/flood light/high mast light/Garden light/Post top light carefully (any capacity, any type) from pole/Building carrying out repair work at site including replacement of unserviceable/ defective screw, nut and bolts, spares etc, refixing the fittings in its original position, testing and commissioning, including removal of bushes, creepers and trimming of branches around the light fitting including taking out fixing site complete all as specified and directed.Notes: (i) If any major repair is required, attending complaints and replacement of any nature in street light network at any point of time, the items shall be replaced with respective item ofBOQis deemed to be inclusive. (ii) Tools, ladder, vehicle required to carry out the work shall be provided by the contractor. (iii) Contractor will ensure the safety of the workers employed at his own risk. (iv) Contractor shall provided Skilled ITI Electrician and Produce the Certificate before the commencement of work. (v) Contractor should ensure all the street lights are functional before leaving the station and represenative of contractor should check after all the street lights are switch ON after rendering completion to respective JEs/Engineer-in Charge as day to day basis. (vi) Contractor has to supply first aid kit to their workers and has to show the Engineer-in-Charge before starting the work. |
| 2 | Supply and fix in repair GI brackets for street light fitting made out of 40 mm dia,1.5 m long, medium grade pipe, bend to 120 degree angle shape, drilled holes etc & fixed with clamps, nuts, bolts etc, complete all as specified and as directed. |
| 3 | Supply & Fix in replacement of LED street light fitting 70 watts energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device complete all as directed |
| 4 | Supply & Fix in replacement LED Flood light fitting Secures 1x200 Watt, pressure die cast aluminum housing, and heat resistant, toughened glass with frame with IP 66 Protection, complete all as specified and as directed. |
| 5 | All as per No 4 here-in above but of 70 Watt, complete all as specified and as directed. |
| 6 | All as per No 4 here-in above but of 50 Watt RGB Colour, complete all as specified and as directed. |
| 7 | All as per No 4 here-in above but of 50 Watt Green Colour, complete all as specified and as directed. |
| 8 | Supply & Fix in replacement, Garden Light fitting, 25 Watt LED Decorative Post top for 360° indirect light with IP 65 protection Resistant to impact and corrosion, Glare-free new generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaries with high power led as light source ,including taking down the old one complete all as specified and as directed. |
| 9 | Supply & Fix in replacement LED post top lantern fitting 40 Watt with aluminium die cast housing cum heat sink with PMMA diffuser with IP 65 protection complete with necessary PCC foundation including taking down existing old pattern unserviceable light fitting all as specified and directed. |
| 10 | Supply & Fix in replacement of decorative Hot-dipped galvanised mild steel step pole of 3.5 Metre height, Mild steel base plate of 268 mm dia, and two sections which having a dia of 110mm and a height of 970 mm for bottom section and a dia of 76mm and a height of 2530mm height for top section, and plasma cut & duly chamfered opening window of 300 x 110 mm for terminal connections & mounting accessories including necessary PCC foundation and earthwork etc complete all as specified and directed. |
| 11 | Supply & Fix in replacement of LED bollard type fitting 10 Watt capacity 650 mm height, LED bollard A Flare fitted with low glare diffuser with IP 65 protection, complete with necessary PCC foundation including taking down existing old pattern unserviceable light fitting complete all as specified and directed. |
| 12 | Material & Labour for Painting to steel tubular pole of any height, any size with two coats of aluminium paint over one coat anti corrosive paint, including preparation of surface, by removing old paint, proper cleaning, filling cavities with filler, marking pole Number as existing, size of 50 mm height in black colour with yellow back ground in round shape of dia maximum up to 150 mm complete all as specified and directed. |
| 13 | Material & Labour for Cement based painting to Concrete pole of any height, any size, including preparation of old surface, marking pole Number as existing, with synthetic enamel paint ,size of 50 mm height, in black colour with yellow back ground in round shape of dia maximum up to 150 mm complete all as specified and directed. |
| 14 | Supply and fix in repair junction box made of glass fiber reinforced and transparent poly carbonate of size 126x228x111mm, KV PC 8104 with IP 65 protection including MCB SP, 6 Amps 1 No and suitable size clamps fixing for pole/in PCC foundation etc, including taking down the old one, complete all as specified and as directed. |
| 15 | Supply and fix in repair Digital time Switches ,DIN type programmable every 1 Minute, with backup of 6 years ,28 Memory locations, current Capacity 16A, weekly program, with 1 change over (1co) total 28 programs, including taking down the old one all as specified and as directed. |
| 16 | Supply and fix in repair power contactor, three pole, 60 Amp, MNX type, all as specified and as directed. |
| 17 | Supply and fix in repair power contactor, three pole 85 Amp, MNX type, all as specified and as directed. |
| 18 | Supply and fix, in repair MCB SP, 6 to 32 Amps,\"C\" curve, 240/415 volt AC, complete all as specified and as directed. |
| 19 | Supply & Fix LED Street light driver 25/45 Watt, complete all as specified and as directed. |
| 20 | Supply & Fix in replacement of LED Street light driver 70/90 Watt complete all as specified and as directed. |
| 21 | Supply & Fix in replacement of LED Street light and flood light driver 100/120/150/200 Watt, complete all as specified and as directed. |
| 22 | Material & Labour for PVC insulated aluminium conductor 3 core 2.5 Sqmm cable to be drawn inside the pole, including taking down of old one complete all as specified and as directed. |
| 23 | Supply & Fix in replacement of street light TIMER control panel, 63 Amps, 3 pole/230Volt, DIGITAL time switch pole/wall mounting made out of 3.15 mm CRCA sheet duly powder coated with locking arrangement, including internal wiring complete with bypass arrangements complete all as specified and as directed. |
| 24 | Supply & Fix 7 Metre GI Octagonal pole single section with bottom dia 130mm, top dia 70mm having sheet thickness 3mm, The door height cutout should not be more than 500mm with door elevation 500 mm, The size of the reinforced rod should be 30x4mm; size of the base plate should be 220x220x12mm, PCD for the holes should be 220 with foundation bolt dia M20, length of the foundation bolt 700mm with four foundation bolts. The Arm should be 1.5 Metre length single arm with 15 degree Arm bracket complete as specified and directed. |
| 25 | Material & Labour for dismantling of old tubular poles duly removing all connection, dismantling PCC platform and taken out from the site complete all as directed. |
| 26 | Material & Labour for dismantling of old concrete poles duly removing all connection, dismantling PCC platform and taken out from the site complete all as directed . |
| 27 | Attending complaints / breakdown of LT electrical system and taking down existing connection from LT Panel/Bus Bar Chamber/Feeder Piller/ Electric Poles/ Building carefully (any capacity ,any type) carrying out repair work at site including replacement of unserviceable/ defective screw/nut & bolts/ Washers/Lugs/Spreaders/Hinges of doors/Repair to Locks & handles/ Indication Lamps/meters/Cable glands/Bus Bar (Copper/Aluminium) etc,refixing the fittings in its original position, testing and commissioning, including removal of bushes, creepers and trimming of branches around the LT Panel/Bus Bar Chamber/Feeder Pillar/ Electric Poles including taking out fixing site complete all as specified and directed. Notes:-(i) If any major repair is required, attending complaints and replacement of any nature in LT Power network at any point of time, the items shall be replaced with respective item of sch \"A\" is deemed to be inclusive (ii) Tools, electrical measuring instruments, ladder required to carry out the work shall be provided by the contractor and has to show the Engineer-in-Charge before starting the work. (iii) Contractor will ensure the safety of the workers employed at his own risk(iv) Contractor shall provided Skilled ITI Electrician and Produce the Certificate beforecommencement of work. (v) Contractor has to supply first aid kit to their workers and has to show the Engineer-in-Charge before starting the work (vi) Contractor should ensure to rendering completion of all attended complaints to respective JEs/Engineer-in Charge as day to day basis. |
| 28 | Supply & laying in replacement and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors,1100 volts grade of size 400 Sqmm 3.5 core complete all as specified. |
| 29 | All as per item No 28 here-in-above but cable of size 300 Sqmm 3.5 core |
| 30 | All as per item No 28 here-in-above but cable of size 240 Sqmm 3.5 core |
| 31 | All as per item No 28 here-in-above but cable of size 185 Sqmm 3.5 core |
| 32 | All as per item No 28 here-in-above but cable of size 150 Sqmm 3.5 core |
| 33 | All as per item No 28 here-in-above but cable of size 120 Sqmm 3.5 core |
| 34 | All as per item No 28 here-in-above but cable of size 95 Sqmm 3.5 core |
| 35 | All as per item No 28 here-in-above but cable of size 70 Sqmm 3.5 core |
| 36 | All as per item No 28 here-in-above but cable of size 50 Sqmm 3.5 core |
| 37 | All as per item No 28 here-in-above but cable of size 35 Sqmm 3.5 core |
| 38 | All as per item No 28 here-in-above but cable of size 25 Sqmm 3.5 core |
| 39 | All as per item No 28 here-in-above but cable of size 16 Sqmm 4 core |
| 40 | All as per item No 28 here-in-above but cable of size 10 Sqmm 4 core |
| 41 | All as per item No 28 here-in-above but cable of size 16 Sqmm 2 core |
| 42 | All as per item No 28 here-in-above but cable of size 10 Sqmm 2 core |
| 43 | Excavating trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out excavated soil/ sand/ unserviceable LT Cable for laying of cable and getting out complete all as specified and directed. |
| 44 | Material & Labour for Sand cushioning and covering of UG cable using rigged sand in trenches for cable protectioncomplete all as specified and directed. |
| 45 | Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm in hard /loose soil complete all as specified and directed. |
| 46 | Removing excavated material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed. |
| 47 | Material & Labour for Brick well burnt Class \"B\" of size 230x115x75mm as in cover to UG cable, laid dry flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exceeding 10mm over UG cable for cable protection in trenched complete all as specified. |
| 48 | Cutting existing road/hardstand/concrete blocks/slabs/brick work or stone masonry of any type by using crow bar chisel up to a depth of 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers cold mix bitumen over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge. |
| 49 | Material & Labour for GI tubing ofsize 40mm dia,medium grade (ISI marked) with all fitting/accessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc complete all as specified and directed |
| 50 | All as per item No 49 here in above butGI pipe of size 50mm dia |
| 51 | All as per item No 49 here in above butGI pipe of size 100mm dia |
| 52 | Repair to existing feeder pillar box after disconnecting all incoming and outgoing cable connections and re-thimbling of various sizes of cables ,including cable loop for required sizes connecting up and makinggoodincluding repairing to doors , fixing hinges and locking arrangements and including painting after removing rusts, dusts etc, with one coat of existing paint complete all as directed. |
| 53 | Material & Labour for marking pole number existing size of 50 mm height in black colour with yellow background in round shape of dia maximum up to 150mm all as specified and as directed by Engineer- In-Charge |
| 54 | Supply and fix cable jointing kit for straight through heat shrinkable type jointwith jointing material andall connected accessories suitable forXLPE armoured aluminium conductorcable 1100voltsgrade of size 3.5 core 240 to 300 sqmmincluding taking down of old one complete all as specified and directed. |
| 55 | All as per item No 54 here in above but cable jointing kit of size 150 to 185 sqmm |
| 56 | All as per item No 54 here in above but cable jointing kit of size 70 to 120 sqmm |
| 57 | All as per item No 54 here in above but cable jointing kit of size 25 to 50 sqmm |
| 58 | All as per item No 54 here in above but cable jointing kit of size 6 to 16 sqmm |
| 59 | Supply & Fix in replacement of MCCB 4 Pole, 630 Amps, 36 KA, 415 V , with adjustablethermal & adjustable magnetic setting Ics=100% Icu complete all as directed. |
| 60 | All as per item No 59 here in above but MCCB 4Pole, 400 Amps, 36 KA, 415 V. |
| 61 | All as per item No 59 here in above but MCCB 4Pole, 320 Amps, 36 KA, 415 V. |
| 62 | All as per item No 59 here in above but MCCB 4Pole, 250 Amps, 36 KA, 415 V. |
| 63 | All as per item No 59 here in above but MCCB 4Pole, 200 Amps, 25 KA, 415 V. |
| 64 | All as per item No 59 here in above but MCCB 4Pole, 160 Amps, 25 KA, 415 V. |
| 65 | All as per item No 59 here in above but MCCB 4 Pole, 125 Amps, 25 KA, 415 V. |
| 66 | All as per item No 59 here in above but MCCB 4 Pole, 100 Amps, 25 KA, 415 V. |
| 67 | All as per item No 59 here in above but MCCB 4Pole, 63 Amps, 25 KA, 415 V. |
| 68 | Material & Labour for earthing complete with galvanized iron or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Metres below ground level) with top edge of earth plate not less than 1.5 Metres below ground level connected to galvanized iron strip 32x6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20 mm medium grade GI pipe, including all excavation and earth work & connecting the earthing to the testing point/transformer neutral/body/LT panel etc, and testing on completion, complete all as specified and directed by Engineer in charge. |
| 69 | Supply and fix in replacementon load change over switch with enclosure 4 pole 250 Amps,36 KA ,415 V Complete all as directed. |
| 70 | Ditto all as per Sl item No 69, but for 400 Amps |
| 71 | Material & Labour for painting of LT panels / Junction Boxes of any size and type with two coats of enamel paint over one coat anti corrosive paint, including preparation of surface , by removing old paint, proper cleaning , filling cavities with filler should applied internally and externally complete all as specified and directed. |
| 72 | Material & Labour for Cement based painting to LT Panel Foundation of any size, including preparation of old surface complete all as specified and directed. |
| 73 | Material & Labour for Cement based painting to Street light / garden light foundation of any size, including preparation of old surface complete all as specified and directed. |
| 74 | Notes for Serial item No 1 to 73 above: Contractor has to quote the tender taking the below mentioned points into consideration and the rates of the above items are inclusive of the below mentioned points. (a) The contractor shall provided skilled ITI electricians and Helpers for 8 Hours from 0900 hrs to 1700 Hours. (b) The contractor has to arrange skilled ITI electricians and Helpers taking into consideration that the complaint will be attended at two places at the same time in Naval base area. (c) All the Lights / LT cable / Electrical components breakdown complaints has to be attended immediately and completed on the same day. (d) Contractor has to note that the complaints will be raised everyday and the contractor staff has to attend the complaints on day to day everyday basis complete for the span of the contract. (e) Contractor has to arrange sufficient labours during breakdowns as directed by the Engineer-in-Charge (f) If the contractor has not attended the complaint on time or delay/pending will be recovered Rs .1000 per day. |
| 75 | Amount of Credit Schedule shall be deducted to arrive the Contract Sum. |