Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-07-2024 | Extension of Bid Due Date | Date | 29-07-2024 |
| 2 | 12-07-2024 | Change in BOQ | BOQ | 24-07-2024 |
| Sl. No. | Item Description |
| 1 | CIVIL WORKS |
| 2 | TOPOGRAPHICAL SURVEY |
| 3 | To carry out detailed Topographic Survey covering specified plots/area of CNG/LCNG Station/RO ,any other locations from approved agency and as directed by Engineer in Charge using survey instruments and giving complete details in the form of drawings (in the scale of 1:100) and reports in 4 copies on white paper sheets and CAD output on CD/DVD all complete as per specifications, drawings and direction of the Engineer-in-Charge. |
| 4 | GEOTECHNICAL INVESTIGATION |
| 5 | Carrying out Drillling holes of 150mm dia. in all type of soil by shell and auger method upto a max. depth required or refusal strata (REFUSAL means when N> 100 for 30 cms of penetration) including recording of water table (if met with within the depth drilled) after completion of boring and conducting the required laboratory tests ( See Note )fromNABL orequivalent accredated labarotary as per ISO/IEC 17025 and as directed by Engineer in Charge including providing all manpower, tools, tackles, materials, survey equipments, drilling rigs, soil testing equipment, other equipments, other support facilities necessary for the survey and associated work and submitting Final Geotechnical Report (along with the soft copy) incorporating all field and laboratory data and recommending the type of foundation and the safe bearing pressure and/or Load bearing capacity of Pile (See Note) for the proposed sites, Drawings, Data etc. (One Lot) in an approved format drawings, approved QAP, implementation schedule and other provisions of the Tender Document and instructions of the Engineer-in-charge. |
| 6 | 0-10m or Refusal |
| 7 | Note :- |
| 8 | 1.Required Laboratory Test such as natural moisture content, liquid limit, plastic limit, shrinkage limit, dry and bulk density, specific gravity, particle size distribution by sieve and hydrometer analysis, triaxial compression test (undrained), permeability test, chemical test on soil samples and water samples, differential free swell test and direct shear test all as per Technical Specifications and direction of Engineer-in-Charge. |
| 9 | 2.Safe bearing pressure at 1.5m , 2.0m and 2.5m below ground or at other depths for open and raft foooting. |
| 10 | 3. Geotechnical design for pile up to 500mm dia, 30T Capacity end bearing/ skin friction typeshall be recommended if required. |
| 11 | 4. Existence of black cotton soil with swelling property andswelling index shall be reported with remedial measures. |
| 12 | 5. RQD value of under laying strata encountered, shall be reported. |
| 13 | SITE CLEARANCE |
| 14 | DEMOLITION OF R.C.C./BRICKS/STONE MASONARYSite clearance by demolition of R.C.C./PCC/Brickwork/Stone Masonry/Stone Soling, Flexible pavements etc. along with removing the debris and disposal of unserviceable material to any lead and staking of serviceable materials, handing over serviceable material to concerned department if requiredas per technical specifications and direction of Engineer-in-charge. |
| 15 | Note: |
| 16 | 1. Rate includes cost of all labour, tools, tackles, hire charges, royalties, levies, leads, loading/unloading, transportation, water, electric power, illumination etc. complete in all respects as per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge. |
| 17 | 2. Demolition of RCC/PCC/Brick Masonry/Road will be paid in NET CUM after deductions for air voidsas demolished. |
| 18 | CLEANING VEGETATIONCleaning bushes including uprooting of rank vegetation, green bush wood, trees and saplings of girth upto 30cms (measured at a height of 1m above ground), stacking the serviceable materials and disposal of the same including rubbish etc. upto any lead and all lift as per specification and direction of the Engineer-n-charge. (payment will be made for actual site clearance area only). |
| 19 | TREE CUTTINGTree cutting (only of girth more than 30 cm above 1m above ground)along with removal of roots and stumps and handing over the same to Owner / Owner\"s Representative including paying royalties, disposal, taking approval from competent authorities etc. all complete, as per technical specifications and direction of Engineer-in-charge. |
| 20 | Note: |
| 21 | 1.Rate includes cost of all labour, tools, tackles, hire charges, royalties, levies,loading/unloading, transportation,electric power, illumination and cost of handingover to owner/or his representative etc. complete in all respects as per scope of workand direction of Engineer-in-charge. |
| 22 | EARTH WORK IN EXCAVATION AND BACKFILLING |
| 23 | Earthwork in excavation for foundations in ordinary soils including soft rock / disintegrated rock in both dry andwet conditions including pumping and bailing out surface and subsoil water, shoring, strutting,slush removal including backfilling in all positions in layers of 300mm at all heights and depths as per drawings and specifications wherever required, in Foundation pits and other places with excavated suitable surplus earth including reclaiming from spoil heaps kept within the plot including dressing and levelling, watering and mechanical compaction etc.,transporting surplus unserviceablesoilupto any lead and spreading in layers and as per specifications and direction of Engineer in charge.The Measurementfor payment shall be for the theoretical volume only and it shall bethe volume of the block ofthe excavation having maximum bottom dimension of thelevelling course/PCC asper drawing and to actual depth. |
| 24 | For depth upto 2.0 m. |
| 25 | For depth beyond 2.0 m |
| 26 | Note: |
| 27 | 1. The Contractor shall take into account in his rate, the provision for excess excavation required for necessary working space, cutting inslopes etc., which may be required for excavation and other allied works and refilling the side slopes and working space in layers as per requirement. |
| 28 | EARTH WORK IN EXCAVATION/ SITE GRADINGIN HARD ROCK |
| 29 | Earth work in excavation in hard rockfor all type and size of foundations inany plan dimension up to required depth including disposal of excavated material up toany leadin all conditions, and disposal of surplus and unserviceable material. Surface to be leveled and neatly dressed complete in all respect as per scope of work, detailed construction drawings and directions of the Engineer-in-charge.The Measurementfor payment shall be for the theoretical volume only and it shall bethe volume of the block ofthe excavation having maximum bottom dimension of thelevelling course/PCC asper drawing and to actual depth. |
| 30 | Note:- |
| 31 | 1. The Contractor shall take into account in his rate, the provision for excess excavation required for necessary working space, cutting inslopes etc., which may be required for excavation and other allied works as per requirement. |
| 32 | EARTH WORK IN FILLING |
| 33 | Supply and Controlled earth fillingwith good quality imported earth from approved source under floors and other places with special compaction to achieve dry density of 95% standard proctor density as per instruction of the Engineer at all heights/depths upto any lead transporting, depositing, compacting and dressing, trimming complete as desired in layers not exceeding 30cm including watering, consolidating by mechanical means as per specifications and instructions of the Engineer. |
| 34 | 1. Rate to include cost of all labour, tools, tackles, equipment, hire charges, cost of sand, right of way, cess, and backfilling using sand in all conditions, etc. |
| 35 | SAND FILLING |
| 36 | Supplying and filling approved quality coarse sand/M sand (Zone II or Zone III) in foundation or under floor, trenches, pits and other places, at all locations in layers of 150 mm thickness including watering and ramming, all lead, lift and depth complete as per drawing and specification and direction of the Engineer. |
| 37 | Note: |
| 38 | 1. Rate to include cost of all labour, tools, tackles, equipment, hire charges, cost of sand, right of way, cess, and backfilling using sand in all conditions, etc. |
| 39 | PLAIN CEMENT CONCRETE |
| 40 | PLAIN CEMENT CONCRETE 1:2:4 (M 15)Supplying and laying plain cement concrete of grade 1:2:4 (M 15) with stone aggregate 20mm down grade (including shuttering if required) infoundations, floors, roof screed, aprons, pits, drains and other mass concrete works, steps, coping of wall, sill etc., at all depths and heights/levelsas per drawings, specifications and directions of the Engineer-in-charge. |
| 41 | Note:Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials, OPC/PPC cement, shuttering in all conditions etc. with all bye works and sundry works. |
| 42 | PLAIN CEMENT CONCRETE 1:3:6 (M 10)Supplying and laying plain cement concrete of grade 1:3:6 (M 10) with stone aggregate 40mm down grade (including shuttering if required) in all levelling courses under foundations, mass concrete works,road works,chambers, trenches,floors and any other locations at all depths complete in all respects as per drawings, specifications and directions of the Engineer-in-charge. |
| 43 | Note:Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials, OPC/PPC cement, shuttering in all conditions etc. with all bye works and sundry works. |
| 44 | REINFORCED CEMENT CONCRETE IN SUBSTRUCTURE |
| 45 | Providing and Laying in position Machine batched and machine mixed Design mix/ Ready mixed for Reinforced Cement Concrete workof grade M-25 using 20mm down size graded aggregate at all depths and heights in substructure using cement content as per approved design mix manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of RMC as applicable, including cost of centering, shuttering and admixtures in recommended proportions as per IS: 9103 to accelerate/retard setting of concrete(improve workability without impairing strength and durability) but excluding cost of reinforcement as per direction of Engineer-in-charge. Mechanical mixers with Hopper along with Weigh Batcher shall also be permitted for use at site with the approval of Engineer-Incharge to produce Design Mix Concrete of specified grade. |
| 46 | Note:1. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as,minimum 43 grade OPC cement/PPC cement including sulphate resistant cement if required, coarse and fine aggregates, admixtures, other minor construction materials, testing of concrete, curing etc. with all bye workscomplete.2. The reinforcement shall be paid separately vide respective item. |
| 47 | REINFORCED CEMENT CONCRETE IN SUPERSTRUCTURE |
| 48 | Providing and Laying in position Machine batched and machine mixed Design mix/ Ready mixed for Reinforced Cement Concrete workof grade M-25 using 20mm down size graded aggregate at all depths and heights in superstructure using cement content as per approved design mix manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of RMC as applicable, including cost of centering, shuttering and admixtures in recommended proportions as per IS: 9103 to accelerate/retard setting of concrete(improve workability without impairing strength and durability) but excluding cost of reinforcement as per direction of Engineer-in-charge. Mechanical mixers with Hopper along with Weigh Batcher shall also be permitted for use at site with the approval of Engineer-Incharge to produce Design Mix Concrete of specified grade. |
| 49 | Note:1. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as,minimum 43 grade OPC cement/PPC cement including sulphate resistant cement if required, coarse and fine aggregates, admixtures, other minor construction materials, testing of concrete, curing etc. with all bye workscomplete.2. The reinforcement shall be paid separately vide respective item. |
| 50 | REINFORCEMENT STEEL |
| 51 | Supplying, Fabricating and Fixing in position TMT Grade Fe 500D reinforcement conforming toIS1786 at all levels and positions including the cost of transport, straightening, cutting, bending, cranking, welding, provision of necessary chairs and spacers, preparation of bar bending schedule and getting the same approved by EIC etc., complete as per drawings and specifications and including cost of binding wire, labour, testing etc., all completein all respects as per detailed construction drawings, technical specifications and direction of Engineer-in-charge. The chairs and spacer bars provided will not be measured for payment. |
| 52 | Note: |
| 53 | 1. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as reinforcement steel, binding wire etc. with all bye works and sundry works complete. |
| 54 | 2. Chairs, Unauthorised Laps, Spacers, Binding wire, Wastage etc. shall be to contractor\"s account. |
| 55 | BRICK WORKIN SUBSTRUCTURE |
| 56 | Providing and laying BRICK WORK straight or curved on plan to any radius using best quality bricks with frog/indent, conforming to sub-class A as per IS:1077 having crushing strength of not less than 50 kg/cm2 in cement mortar 1 :4 (1 Cement : 4 Coarse Sand)in all types of foundation and substructurework at all depths/heights including projections, pillars, parapets, ornamentals of any shape, cornices, all complete including cut work, curing, scaffolding,including filling of joints with Cement Mortar 1:4 and racking of joints, etc. as per specifications, drawings and directions of the Engineer. |
| 57 | Note: |
| 58 | Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as minimum 43 grade cement (OPC/PPC), bricks, finishes, weep holes, other minor construction materials, shuttering, staging, masonry work,etc. as per requirementwith all bye-works and sundry works complete as per drawings. |
| 59 | BRICK WORKIN SUPERSTRUCTURE |
| 60 | Providing and laying BRICK WORK straight or curved on plan to any radius using best quality bricks with frog/indent, conforming to sub-class A as per IS:1077 having crushing strength of not less than 50 kg/cm2 in cement mortar 1 :4 (1 Cement : 4 Coarse Sand)in all typessuperstructure work at all depths/heights including projections, pillars, parapets, ornamentals of any shape, cornices, all complete including cut work, curing, scaffolding,including filling of joints with Cement Mortar 1:4 and racking of joints, etc. as per specifications, drawings and directions of the Engineer. |
| 61 | Note: |
| 62 | Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as minimum 43 grade cement (OPC/PPC), bricks, finishes,other minor construction materials, shuttering, staging, masonry work,as per requirementwith all bye-works and sundry works complete as per drawings. |
| 63 | BOUNDARY WALL (Superstructure) |
| 64 | Providing, constructing and finishing of compound wall in RCC frame structure with 300mmx350mm column size at an interval of 3.0 m or as specified and height 2.1m with infill brick masonry230 thk , 900mm high Y angle frames with Concertina coils and RBT tape as specified as per scope of work anddetail construction drawings, including plastering, coping, painting, whitewash,concertina coil,finishes all complete as per technical specifications and direction of the Engineer-In-Charge.Note:1. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as minimum 43 grade OPC/PPC cement, RCC M25,Reinforcement steel , concertina coil finishes, bitumen, Y angle, other minor construction materials, shuttering, staging, coping, expansion gap filling with \"Capcell\" armoured board and white sealant material,plastering,painting and all other sundry works.2.Foundation/ sub-structure to bepaid separately vide respective item.3. To be read with in conjunction with Particular Job Specification and tender drawing no. MEC/05/11/C/STD/CGD/002. |
| 65 | PAVER BLOCK FLOORING |
| 66 | Supplying and placing in position as per approved pattern of Cement Concrete Inter locking/grass jointed paver block 80 mm thick of approved shape, rough finish, M-40 strength of approved brand laid over the sand bed of minimum 50 mm thick. The CC interlocking blocks to be of uniform Grey colour or as approved by EIC complete in all respects as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-in-charge. |
| 67 | Note :- |
| 68 | 1. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such paver blocks,sand,earth work in excavation in cutting earth in all conditions, shutteringwith all bye works and sundry works. |
| 69 | 2.PCC below paver shall be paid separately vide respective item. |
| 70 | SINGLE S.S.TUBE TRENCH IN FORECOURT |
| 71 | Providing and construction ofSingle SS tube trench in brick masonry over the 100 mm thick PCC (1:3:6)base with precast SFRC coversof 600x550X 70 mm thk along with edge angle (ISA 75x75x6) and fixing of ISA 50x50x6 for supporting pipe trays @ spacing of 1000 mm c/c along the trench, including 12 mm in CM 1:4 plastering of walls of trenches complete in all respect as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-in-charge. |
| 72 | Note: |
| 73 | 1. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as minimum 43 grade cement, bricks, Edge angle, angle for supporting pipe trays, precast SFRC covers (600X550X70), aggregates / sand , finishes, bitumen, other minor construction materials, shuttering , staging, earthwork in excavation and backfilling using serviceable/ borrow earth in all conditions, shoring/strutting, bailing and pumping out water, masonry work, plastering etc. with all bye works and sundry works.2.To be read with in conjunction with Particular Job Specification and tender drawings. |
| 74 | DOUBLE S.S.TUBE TRENCH IN FORECOURT |
| 75 | Providing and construction ofdouble SS tube trench in brick masonry over the 100 mm thick PCC (1:3:6)base with precast SFRC covers of 600x550X 70 mm thk along with edge angle (ISA 75x75x6) and fixing of ISA 50x50x6 for supporting pipe trays @ spacing of 1000 mm c/c along the trench, including 12 mm in CM 1:4 plastering of walls of trenches complete in all respect as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-in-charge. |
| 76 | 1. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as minimum 43 grade cement, bricks, Edge angle, angle for supporting pipe trays, precast SFRC covers(600X550X70), aggregates / sand , finishes, bitumen, other minor construction materials, shuttering , staging, earthwork in excavation and backfilling using serviceable/ borrow earth in all conditions, shoring/strutting, bailing and pumping out water, masonry work, plastering etc. with all bye works and sundry works.2.To be read with in conjunction with Particular Job Specification and tender drawings. |
| 77 | PLASTERING |
| 78 | Providing and applying 15 mm thick cement plaster 1 : 4 (1 cement : 4 medium coarse sand) smooth finish at all depths & heights on faces of walls, pillars, projection, bands, etc., including raking out joints if any left out, necessary dabbing, curing, scaffolding complete at all heights as per specification and drawings. |
| 79 | Note: |
| 80 | Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as minimum 43 grade cement (OPC)/PPC cement, coarse sand and other minor construction materials as per requirementwith all bye-works and sundry works complete as per drawings. |
| 81 | PRE CAST COVERS |
| 82 | Providing, hoisting and fixing up precast reinforced cement concrete of M-25 grade(20mm nominal size) in trenches, pits, tanks and the like including the cost of required centering, shuttering (with smooth surface) complete but excluding cost of reinforcement. |
| 83 | Note :- |
| 84 | 1. The reinforcement shall be paid separately vide respective item. |
| 85 | INSERTS |
| 86 | Supplying, Fabricating, Fixing at all levels and positions Steel embedments/ Insertslike Plates,Angle, Channels,Anchor boxes, MSpipe Sleeves includingthreading etc.,including two coats of approved quality Synthetic enamel paint over a primer coat on the exposedSurfaces wherevernecessary, complete as per Drawings, Specificationsand directions of theEngineer-in-charge. (Jigs, Templatesand Fixtureswillnot be paidseperately). |
| 87 | BOLTS |
| 88 | Supplying and Fixing BOLTS & NUTSas per IS: 2062 /SAE 1018 with minimum yield strength of 250 MPAin concrete at all levels and positions, bolts with nutsand washers, pipe sleeves etc. including painting the exposed surfaces with two coats of approved paint, providing grease to exposed area of bolts, welding wherever necessary, complete as per drawing, specifications and instruction of engineer(PCC blocks, jigs and fixtures will not be paid extra) and protecting the same till final erection. |
| 89 | EXPANSION JOINTS |
| 90 | Providing and laying 25 mm thick 150 mm deep expansion/seperation joint along the periphery of pump foundations, pedestals, flooring with approved bituminous impregnated fibre board conforming to IS 1838 including sealing the top 20mm depth with bituminous mastic sealant at all heights and locations with all bye-works complete as per drawing, standard practice as directed by engineer |
| 91 | GROUTING |
| 92 | Providing and laying a ready mix non-shrink cementitious grout of compressive strength of 30 N/mm2 under equipment base plate, anchor holes, etc. at all levels complete in all respects as per specifications, drawing and direction of the Engineer. |
| 93 | G.I.PIPES |
| 94 | Providing and fixingof following size of G.I. pipes (medium duty) as per IS 1239 complete with G.I. fittings and clamps including cutting by hack saw, bending by hydraulic machine, trenching and refilling etc. including all labour and material complete as per approved drawing and direction of EIC. |
| 95 | 50 mm nominal bore |
| 96 | 100 mm nominal bore |
| 97 | 150 mm nominal bore |
| 98 | CONCRETE PIPES (NP3 TYPE) |
| 99 | Providing and laying non-pressure NP3 class (medium duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including trenching and filling complete as per direction of Engineer in charge. |
| 100 | 150 mm dia |
| 101 | 300 mm dia |
| 102 | 600 mm dia |
| 103 | RAIN WATER HARVESTING PIT |
| 104 | Providing,constructing and finishing of rain water harvesting pit including boring up to ground water table, provision of filter media and construction of pit complete asper scope of work, detailed construction drawings and directions of the Engineer-in-charge. |
| 105 | 1.Rate to include cost of all labour, tools, tackles, equipment, hire charges,supply of all materials, such as minimum 43 grade OPC cement, bricks of class designation M-7.5 of IS: 1077 in CM1:4 (1 cement ;4 sand),bitumen,other minor construction materials, shuttering, staging,providing and placing R/F steel, inserts etc. with all by works and sundry works complete.2.To be read with in conjunction with Particular Job Specification and tender drawings. |
| 106 | BOULDER SOLING |
| 107 | Providing and laying 115 to 150 mm thickness dry trap rubble stone (granite/basalt) soling at all depths including hand packing, filling the interstices with chips, spalls and binding with grit and selected murrum, watering, compaction by hand ramming & rolling with 1 MT hand roller etc. complete as per attached job procedures, technical specification and as per direction of EIC. |
| 108 | KERB STONE FIXING |
| 109 | Providing and fixing precast concrete Kerb stones (125 wide X 300 deep approx.) of M-30 grade or equivalent of approved make and shapeat or near ground level as per approved pattern and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand) including the cost of required centering, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 (1 cement : 3 fine sand) wherever required over 75 mm thick PCC M-10 levelling course, complete in all respects as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-In-Charge. |
| 110 | 1. Rate to include all labour, tools, tackles, factory manufactured & steam cured Kerb Stones, shuttering, transportation, water charges, earth work if any, PCC etc complete. |
| 111 | Painting(APEX / Weather coat / Weather shield) |
| 112 | Supplying and applying 3 coats of Apex paint of Asian paints/Weather coat of Berger paints/ Weather shield of ICIpaints on external walls surfaces in approved colour at all heights as per scope of work and recommendations of manufacturer including surface preparation, primer putty etc. detailed construction drawings , technical specifications and directions of the Engineer-In-Charge. |
| 113 | [Rate to include priming coat of putty, scaffolding, tools & tackles consumables etc complete.] |
| 114 | Painting (OBD) |
| 115 | Supplying and finishing internal walls and ceilings in plaster of paris punning to achieve an even finish and applying 3 coats of Oil Bound Distemper of Asian paints/ Berger/ICIbrandin approved colour including surface preparation, primer, putty etc. as per scope of work, detailed construction drawings , technical specifications and directions of the Engineer-In-Charge. |
| 116 | [Rate to include priming coat putty, POP punning, scaffolding, tools & tackles etc complete. ] |
| 117 | White washing |
| 118 | White washing with Dehradun/Rajasthan lime in 3 or more coats to give an even finish including the cost of adding required adhesive (DDL), blue pigment (Robin Blue) etc. on walls, ceiling etc. complete in all respects as per scope of work, detailed construction drawings , technical specifications and directions of the Engineer-in-charge. |
| 119 | [Rate to include whitening, scaffolding, tools & tackles etc complete. ] |
| 120 | EXTERNAL DEVELOPMENT |
| 121 | Preparing the bed by scarifying and deweeding existing surface, placing humus earth mixed with manure/cow dung in the ratio of 8:1 for a depth of 30 cm, rough dressing, fine dressing, levelling and flooding with water, planting of selection 1 species of grass with5 cm X 5 cm spacing as indicated by site incharge and thereafter maintenance and watering for 45 days including all labours, tools, tackle, complete. |
| 122 | Note:1.Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as earth, plant material, manure, pesticides, earthwork etc., with all bye works and sundry works.2. The rate to include all replacements, maintenance, watering etc. for 1 year.3. To be read in conjunction with relevent clause of PJS. |
| 123 | Speed Breaker |
| 124 | supply and installation of high grade rubber and PVC made Speed Breakers at ingress and egress. Make, size and type shall be as per directions of Engineer-In-Charge |
| 125 | PILING UNDER FOUNDATION |
| 126 | Providing and fixing in position \"Bored cast in situ RCC piles skin friction/end bearing type 500 mm diameter and 30 T capacity in M 30 Concrete\" excluding the cost of reinforcement and getting the designs of same approved by MECON/ CLIENT including driving in ground/Hard Rock at specified locationsby using standard tools for construcing a rigid support base for supporting the plant building, buildings etcincluding all bye works, complete as per drawings, specification and directions of the Engineer-in-charge. |
| 127 | Notes-1. Rate to include cost of all labour, tools, tackles, equipment, hire charges,supply of all materials,pile head breaking,head prepration, shuttering, providing and fixing reinforcement steel testing etc. with all bye works and sundry works and consumables. |
| 128 | 2. Reinforcement will be paid seperately in respective SOR item. |
| 129 | Vertical load testing of Single pile upto 30 tonne capacityin accordance with IS 2911 (Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. |
| 130 | Initial test |
| 131 | Routine test |
| 132 | STEEL STRUCTURAL WORKS |
| 133 | Supply, fabrication & erection of Steel structure |
| 134 | Supplying, Fabricating & Erecting in position steel structures fabricated from MS rolled section conforming to IS:2062 and/or from pipes conforming to IS:1161 for cascade supporting structures, loading/unloading platform, MS Gratings, Cat Ladder, handrails, hoardings for signages, LCV stand, etc. or any other structures required as per constructon drawings for completion of works, including surface preparation by mechanical cleaning including application of one coat of Zinc phosphate primer of DFT 35 microns at shop, second coat of Zinc phosphate primer of DFT 35 microns at site after erection and two coats of finishing paint of synthetic enamel of DFT 25 microns each per coat at site, including loading, transportation and unloading delivery at erection site of all fabricated structures, storage and handling at site, site assembly and finally erection of structures at appropriate location, alignment and welding of all structures true to line, level, plumb and dimension. The work shall be completed in all respect as per drawings, technical specification and direction of the Engineer-in-Charge. |
| 135 | Providing and Fixing Fencing Structure |
| 136 | Supplying, fabricating & fixing of steel structural fencing fabricated from pipes conforming to IS:1161 and plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, including surface prepartion by mechanical claening including application oftwo coats of approved quality of synthetic enamel paint over atwo coat of primer in approved shade including loading, transportation and unloading delivery aterection site,ofall fabricated structures ,storage and handling at site, site assembly and finally erection of structures at appropriate location, alignment and welding of all structures true to line, level, plumb and dimension including making pokets & pouring with PCC (1:2:4) in of block 500x500x500 for fixing of postsetc complete as per drawing, technical specifications,scope of works and directions of the Engineer-In-Charge. |
| 137 | Fencing height 2.1m |
| 138 | Providing and Fixing Fencing Gates |
| 139 | Supply, fabrication & fixing of fencing gates fabricated from pipes conforming to IS:1161, plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, locking arrangement, etc., including surface prepartion by mechanical claening including application of two coats of approved quality of synthetic enamel paint over two coats of primer in approved shade including loading, transportation and unloading delivery aterection site of all fabricated structures, storage and handling at site, site assembly and finally erection of structures at appropriate location, alignment and welding of all structures true to line, level, plumb and dimension including making pokets & pouring with PCC (1:2:4) in block of size 500x500x500mm for fixing of posts etc. complete as per drawings, technical specifications, scope of works and directions of the Engineer-In-Charge. |
| 140 | 4m Wide x 2.1m High |
| 141 | 2m Wide x 2.1m High |
| 142 | Providing and fixing chequered plate covers |
| 143 | Providing and fixing chequered plate in panel over cable trench, man hole cover & over steel structure platform including cutting, welding of stiffners, hoisting, fixing in position, and applying two or more coats of approved quality synthetic enamel over a priming coat of approved colour etc. complete as per scope, detailed drawings, technical specifications and directions of the Engineer-In-Charge. |
| 144 | Mechanical & Piping Works |
| 145 | SECTION-A : SS TUBE & FITTINGS - SUPPLY, LAYING & TESTING |
| 146 | Laying, testing and commissioning of SS tubes along with fittings as per Technical Specification, Typical P & ID for type of CNG station and scope of work including handling, lifting, transportation from stores toCNG stations. |
| 147 | 1”OD X 0.120” min Wall thk.SS Tube (ReferTS Section III - A) |
| 148 | ¾”OD X 0.095” min Wall thk.SS Tube (ReferTS Section III - A) |
| 149 | ½”OD X 0.083” min Wall thk.SS Tube (ReferTS Section III - A) |
| 150 | SUPPLY OF SS TUBES as per Technical Specification |
| 151 | 1”OD X 0.120” min Wall thk.SS Tube (ReferTS Section III - A) |
| 152 | ¾”OD X 0.095” min Wall thk.,Material SS316SS Tube (ReferTS Section III - A) |
| 153 | ½”OD X 0.083” min Wall thk.,Material SS316 SS Tube (ReferTS Section III - A) |
| 154 | SECTION-B:Supply of SS Fittings,Valves |
| 155 | Quick Connect Body & Stem |
| 156 | End connection:½\" Tube OD, for stem & ½”NPT (F) for body Material : SS316; Rated pressure : 5000 PSI @ 70°F Temperature: 0°F to 400°F |
| 157 | Plug |
| 158 | Size : ½\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 159 | Size : ¾\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 160 | Size : 1\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 161 | Caps |
| 162 | Size : ½\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 163 | Size : ¾\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 164 | Size : 1\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 165 | Union |
| 166 | Size : 1” OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 167 | Size : ¾” OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 168 | Size : ½\" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 169 | Reducing Union |
| 170 | Tube OD 1\" x Tube OD 3/4\", Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 171 | Tube OD 3/4\" x Tube OD 1/2\", Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 172 | Equal Tee |
| 173 | Size:½” OD x ½” OD x ½” OD, Material:SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 174 | Size: ¾\" OD x ¾\" OD x ¾\" OD, Material : SS316 ( Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 175 | Size: 1\" OD x 1\" OD x1\" OD, Material : SS316 ( Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 176 | Reducing Union Tee |
| 177 | ¾\" OD x ½\" OD x ¾\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 178 | 1\" OD x ¾\" OD x 1\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 179 | Tube End Connection |
| 180 | ½” Tube End & ¾” OD with Ferrule Fitting, SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 181 | Nut |
| 182 | 1 \" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 183 | ¾ \" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 184 | ½\" OD, Material : SS316(Rated pressure : 6000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 185 | Front Ferrule |
| 186 | 1\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 187 | 3/4\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 188 | ½\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 189 | Back Ferrule |
| 190 | 1\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 191 | 3/4\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 192 | ½\" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 193 | Male Connector |
| 194 | Size ¼” NPT (M) x 3/8” OD, SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 195 | Size 1/2” NPT (M) x 3/8” OD, SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 196 | Cross |
| 197 | 3/4\" OD X 3/4”X 3/4\" OD X3/4\" OD Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
| 198 | SS Ball Valves, conforming to MECON’s Technical Specification No. MEC/TS/05/62/048 for SS Ball Valves of following sizes, specifications as indicated below : |
| 199 | 2-Way Floating Normal Bore Ball Valve 1\" |
| 200 | 2-Way Floating Normal Bore Ball Valve ¾\" |
| 201 | 2-Way Floating Normal Bore Ball Valve ½\" |
| 202 | 3-Way Trunnion Mounted, Reducer BoreBall Valve ½\" OD end Connection and ¼” NPT (F) bottom end connection |
| 203 | Conductive Core Thermoplastic Hose |
| 204 | 3/8” ID Conductive Core Thermoplastic Hose for CNG Service with break away coupling |
| 205 | Laying, testing and commissioning of SS 304 Tubes along with isolation valves, reducers & fittings etc.as per Technical Specification, Typical schematic drg. for Ins. air line of CNG station and scope of workincluding handling, storage,lifting, transportation upto CNG stations.(Note:Total no.offerrule fittings may be considered as one jointing ferrule at every 5.0 m) |
| 206 | ½”OD X 0.083” min Wall thk.SS Tube (ReferTS Section III - A) |
| 207 | SECTION-B : ERECTION OF MECH. EQUIPMENT |
| 208 | Handling (including lifting and transportation from Client\"s store within city toCNG stations)and erecting in position, the following equipmenteither on the foundation at Ground level or on roof at 3.5 m above ground level.Contractor\"s scope shall include supply of all material and accessories including but not limited to any fixtures, clamps, gasket, nut bolts, etc. : |
| 209 | Cascade 4500/3000/2200L water capacity. Erection at + 4.0 M level (ReferTS Section III - B) |
| 210 | Cascade 4500/3000/2200 L water capacity, Erection at + Ground level (Refer TS Section III - B) |
| 211 | Dispenser Erection at + Ground Level |
| 212 | Note: The quantities given above against individual items are indicative and shall not be considered to be binding.The quantities may increase or decrease at site at the time of actual execution and as per the discretion of Owner/ Engineer-in-charge.The unit rate shall be operated to work out the final payment due to Contractor. |
| 213 | SECTION-C : SUPPLY, ERECTION & COMMISSIONING OF MISCELLANEOUS ITEM |
| 214 | Supply, erection & commissioning of following miscellaneous items as per technical specification and at locations (within the stations) as directed by EIC |
| 215 | Air compressor pump (ReferTS Section III - C) (Tyre Inflator) |
| 216 | Water cooler (ReferTS Section III - C) |
| 217 | Fire fighting Equipments (ReferTS Section III - C) |
| 218 | DCP -9 Kg |
| 219 | DCP -75 Kg |
| 220 | CO2 – 4.5 Kg |
| 221 | Sand Bucket (4 Nos. on each strand) |
| 222 | Wind Socks |
| 223 | RE-TRANSPORTATION AND ERECTION OF DCU SKIDS & OTHER EQUIPMENTS |
| 224 | Handling, including lifting, transportation from Company\"s stores to Contractor\"s work-shop for fabrication or/ and to worksite for field fabrication, assembly of parts/ sub-assemblies, erection for all Metering skids/DRS/MRS/DCU/Compressors, equipment supplied by company, above ground/ underground at all elevation/ depth, fixing of foundation bolts, welding whereverrequired, aligning, grouting, hooking-up, cleaning and flushing by water draining, drying by compressed air, providing all mountings, ancilliary, enabling works as required and completing in all respect as per drawings, specification and instruction of Engineer-in-charge. Contractor\"s scope shall include supply of all material and accessories including but not limited to any fixtures, clamps, gasket, nut bolts, finish coat ofpainting including rub down & touch up of shop primer/ paint scrapping of shop primer/ paint and further their painting after application of primer as per specification, wherever required by Company. |
| 225 | Details of equipment are as under |
| 226 | Metering Skids/ MRS/DRS/DCU/Compressors.. ...etc |
| 227 | 1) Payment for Hook up with above agound steel pipe line is covered in the above SOR item. |
| 228 | 2) The quantity mentioned against above SOR item arefor multiple equipment having different weight and weight of each eqipment shall be maximum upto 10.0 MT. The each equipment shall be installed at different location within the GA. Max distance from Store to store/site shall be 50 Km. |
| 229 | Liasioning and obtaining permissions/License/ NOC from the statuatory / concerned authorities for each station. |
| 230 | Collecting the request letters from client for statutory approval/permission, follow up, submitting the request letter at designated offices, resubmission after correction/modification if required, soft and hard copy in nos. as required /if required in sizes, carrying out necessary paper work and liasion with the authorities to obtain access permission and clearance from NH/SH/PWD/Other Road, Fire & safety clearance, trade license, factory license, AAI permission, PCB & local administration/departments permission and PESO license for each CNG station & DCU installation etc. Obtaining work permits /NOC from various statutory authorities having jurisdiction before execution of the work and complying with all stipulations /conditions/recommendations of the said authorities. Only statutory fees shall be paid by the owner. |
| 231 | Note: Payment shall be done to the contractor only when all the permissions required for commissioning of the CNG station/DRS/DCU are obtained and submitted to client. |
| 232 | ELECTRICAL WORKS (SUPPLY) |
| 233 | SUPPLY |
| 234 | Design, engineering, manufacture, shop testing, supply including packing and forwarding, transportation, delivery at storage and from storage to site of power distribution board (PDB) : |
| 235 | 415 V, 36 KA single front type indoor PDB to receive input power consisting ofbus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/23VM/05/E9/E/1081A & as per standard Specification.Single incomer of125Amp (with Single phase preventer & VMR) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) .Outgoing with 01 no. 80 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE).Outgoing with 01 no. 63 Amp TPN MCCB(with TM based O/C,S/C & E/F RELASE).Outgoing with 03 nos. 32 Amp TPN MCCB(with TM based O/C & S/CRELASE).Outgoing with 3 nos. 40A Fuse and 3 nos. 10A DP MCBwith Timer(24Hrs) Auto/Mannual. Outgoing with 3 nos. 40A Fuse and 3 nos. 10A DP MCBwithout Timer. |
| 236 | 415 V, 36 KA single front type indoor PDB to receive input power consisting ofbus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/23VM/05/E9/E/1081B & as per standard Specification.Single incomer of 100Amp (with Single phase preventer & VMR) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) .Outgoing with 03 nos. 32 Amp TPN MCCB(with TM based O/C & S/CRELASE).Outgoing with 3 nos. 40A Fuse and 3 nos. 10A DP MCBwith Timer(24Hrs) Auto/Mannual.Outgoing with 3 nos. 40A Fuse and 3 nos. 10A DP MCBwithout Timer. |
| 237 | Poly Carbonate enclosure IP65 Power Distribution Board (PDB), Distribution Panel :415V, 36 KA single front, floor mounted, modular type, indoor/outdoor application, consisting ofCu bus bar, cable termination, flameproof LCS, etc. including all labour and materials with operating mechanism, all accessories, erection & commissioning spare,etc., complete in all respects as specified in technical specification, data sheet & tender SLD (No. MEC/23VM/05/E9/E/1081C). Dimension shall be limited to 1800mm(H) X 1800mm(W) X 400mm(D).Panel shall be made of polycarbonate with glass fiber rienforced. Panel shall be environment friently, UV resistannt, recyclable, halogen & silicon free, anticorrosive and anti acid. Panel shall be fire retardant in accordance IEC 60695-2-11. It shall be tested at glow wire test for 960 deg C. Single In-comer of 125 Amp (with Single phase preventer ) 4P MCCB (with Micro processor based O/C,S/C & E/F RELEASE WITH LSIG & SHUNT TRIP) with contactor and interlock etc.Outgoing with 01 ns. 80 Amp TPN MCCB(with TM based O/C,S/C & E/F RELASE) for Booster CompressorOutgoing with 01 no. 63 Amp TPN MCCB(with TM based O/C,S/C & E/F RELASE).Outgoing with 03 nos. 32 Amp TPN MCCB(with TM based O/C & S/C& E/F RELASE) for UPS and Static Bypass.Outgoing with 3 nos. 40A Fuses and 3 nos. 10A DP MCBwith Timer(24Hrs) Auto/Mannual Outgoing with 3 nos. 40A Fuses and 3 nos. 10A DP MCBwithout Timer |
| 238 | Poly Carbonate enclosure IP65 Power Distribution Board (PDB), Distribution Panel :415V, 36 KA single front, floor mounted, modular type, indoor/outdoor application, consisting ofCu bus bar, cable termination, flameproof LCS, etc. including all labour and materials with operating mechanism, all accessories, erection & commissioning spare,etc., complete in all respects as specified in technical specification, data sheet & tender SLD (No. MEC/23VM/05/E9/E/1081D). Dimension shall be limited to 1800mm(H) X 1800mm(W) X 400mm(D).Panel shall be made of polycarbonate with glass fiber rienforced. Panel shall be environment friently, UV resistannt, recyclable, halogen & silicon free, anticorrosive and anti acid. Panel shall be fire retardant in accordance IEC 60695-2-11. It shall be tested at glow wire test for 960 deg C. Single In-comer of 100 Amp (with Single phase preventer ) 4P MCCB (with Micro processor based O/C,S/C & E/F RELEASE WITH LSIG & SHUNT TRIP) with contactor and interlock etcOutgoing with 03 nos. 32 Amp TPN MCCB(with TM based O/C & S/C& E/F RELASE) for UPS and Static Bypass.Outgoing with 3 nos. 40A Fuse and 3 nos. 10A DP MCBwith Timer(24Hrs) Auto/Mannual Outgoing with 3 nos. 40A Fuse and 3 nos. 10A DP MCBwithout Timer |
| 239 | Poly Carbonate enclosure IP65 Power Distribution Board (PDB), Distribution Panel :415V, 36 KA single front, floor mounted, modular type, indoor/outdoor application, consisting ofCu bus bar, cable termination etc. including all labour and materials with operating mechanism, all accessories, erection & commissioning spare,etc., complete in all respects as specified in technical specification, data sheet & tender SLD (No. MEC/23VM/05/E9/E/1081E). Dimension shall be limited to 1800mm(H) X 1800mm(W) X 400mm(D).Panel shall be made of polycarbonate with glass fiber rienforced. Panel shall be environment friently, UV resistannt, recyclable, halogen & silicon free, anticorrosive and anti acid. Panel shall be fire retardant in accordance IEC 60695-2-11. It shall be tested at glow wire test for 960 deg C. Dual In-comer of 63/63 Amp (with Single phase preventer ) 4P MCCB (with Micro processor based O/C,S/C & E/F RELEASE WITH LSIG & SHUNT TRIP) with contactor and interlock etcOutgoing with 02 nos. 32 Amp TPN MCCB(with TM based O/C & S/C& E/F RELASE) for UPS and Static Bypass.Outgoing with 1 no. 40A Fuse and 3 nos. 10A DP MCBwith Timer(24Hrs) Auto/Mannual Outgoing with 1 no. 40A Fuse and 3 nos. 10A DP MCBwithout Timer |
| 240 | Outdoor type, Microprocessor based MCCB encased with dust & weather proof with following rating for mounting on wall or pedestal. 125A, 415V, 4P AC23 and suitable for termination of 3.5 x 120/95 sq.mm A2XFY cable on incomer terminals andoutgoing terminals.Enclosure shall be made of polycarbonate with glass fiber rienforced. Panel shall be environment friently, UV resistannt, recyclable, halogen & silicon free, anticorrosive and anti acid. Panel shall be fire retardant in accordance IEC 60695-2-11. It shall be tested at glow wire test for 960 deg C. |
| 241 | Floor mounted sheet steel APFC Panel of 10KVAR capacitor bank in steps of 4x2.5 KVAR capacitors consisting of bus bar chamber, cable alley incoming (MCCB), outgoing feeder (MCBs) as specified in tender specification. |
| 242 | Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 125A, 415V, 4 Pole AC-23 duty and suitable for termination of 3.5CX120/95/50 sq.mm A2XFY cable on incomer terminals and outgoing terminals with On, Off, Trip, RYB Indication, Voltmeter & Ammeter etc. |
| 243 | Design, engineering,supply includingpacking and forwarding, transportation, delivery at storage, of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043. |
| 244 | Earth Pits- GI PIPE Electrode with 6 mm thick chequered plate cover |
| 245 | Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover |
| 246 | GI Strip (50X6) mm |
| 247 | GI Strip (25X3) mm |
| 248 | GI lightning rod 25 mm dia. 1800 mm long including supply of all hardware bare copper rope labour etc. complete as per approved drawings, specifications and directions of Engineer-In-Charge. |
| 249 | Arrangement for Earthing of LCV with Flexible green Cu wire (10 sqmm of 30 Meter length) ,Clamp (includingbolting arrangement) ,Flexible PVC and other item etc. |
| 250 | Design, engineering,supply includingpacking and forwarding, transportation, delivery at storage, of the 1.1kV grade XLPE insulated, PVC sheathed, FRLS power and control cables (conforming to IS:7098 and specification) of following sizes in trenches/ excavated under ground trench /trays, pulling through pipes and its proper sealing, cutting of paved area, roads etc. |
| 251 | 3.5x 95 mm2 A2XFY |
| 252 | 3.5x 50 mm2 A2XFY |
| 253 | 4x10 mm2 2XWY |
| 254 | 4x 6 mm2 2XWY |
| 255 | 4x 2.5 mm2 2XWY |
| 256 | Supply includingpacking and forwarding, transportation, delivery at storage of lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects. |
| 257 | Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear Model no. FLPW-1095 of Baliga make or equivalent) |
| 258 | Supply of Integral flame proof Flood Light fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire Baliga make or equivalent) |
| 259 | Street lighting pole 6mtr high GI octagonal pole (Type BOP-6030 of Bajaj make or equivalent) complete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing (MEC/SD/05/E9/77/04) & specification (MEC/TS/05/E9/077B). |
| 260 | SUPPLY OF DISTRIBUTION TRANSFORMER |
| 261 | Supply includingpacking and forwarding, transportation, delivery at storageto site of 11 kv/433 V outdoor type,3Ph,50Hz,copper wound, Dyn11, ONAN distribution transformer complete with all accessories as per REC specification 11/1976 and/or IS 2026/1180. and latest amendments there of and first oil filled. Termination arrangement for HV side : HT bushing & LV side Cable end box/Terminal box of following rating (Make of Transformershall be approved from State Electricity Board/MECON.) |
| 262 | 63KVA |
| 263 | 25KVA |
| 264 | Supply of all the items listed at (Sl. No. 34 to 37 below)all miscellaneous materials etc as required to complete the HT & LT installation as per the tender. (All electrical equipments shall be approved from State Electricity Board/MECON.) |
| 265 | Double pole Structure with MS joist ISMB 200 x 100 mm, 9 m long complete with 100 x 50 mm MS channels of required length and size ;11 kV3 Ph. horizontal Gang operated Air Break switch, DO fuse, lightning arrestors of suitable ampere rating;pin insulators, disc insulators, operating rod, handle, locking arrangement, copper wire for jumper connection, stay set complete with all accessories etc as required inclusive of paint (two coats of primer & twocoats of final aluminum paint) and concrete foundation. |
| 266 | Supply,of 11 kV, ACSR weasel conductor as required for stringing between State Electricity Board Double pole and consumer double pole structures. |
| 267 | Chain link fencing of (height 2.5 m) for the sub station area with ISA 50 x 50 x 6 mm angle and 4 mm thick welded wire mesh and 1 no. gate ( 3x3 mtr.) complete with all material, welding and labour etc(20 mtrs/set). |
| 268 | 40 mm blue granite metal for spreading in the fenced area . |
| 269 | Supply of point wiring as per details in construction drawing & specificationincludesPVC conduits in ceiling, complete wiring including Wiring for main/ submain from DBs to switchboard and from switchboard to light/power points with 6/4/2.5/1.5 sq.mm. FR PVC insulated copper conductor multi starnd wire in PVC conduit in recess/ trench as required, switch boxes & switches (ANCHOR ROMA make or equivalent) for following items- |
| 270 | Light Point |
| 271 | Surface/ recess mounted LED light fixrure with LED lamp (type LCTL-36 -CDL of CG make or equivalent). |
| 272 | Socket outlet (5/15 Amp combination) of ANCHOR ROMA make or equivalent |
| 273 | Ceiling fan with electronic regulator ( Energy efficent, 50W, 1200 mm sweep) |
| 274 | UPS SYSTEM |
| 275 | Design, supply, packing, forwarding, delivery by equipment supplier at site including commissioning spares as requiredof UPS systems as per specification, block diagram and following rating : |
| 276 | 3KVA, 230 V Single phase, 50 Hz, single industrial type, UPS system suitable for input Power supply voltage of 320V-460V-TPN with healthy single-Phase Selection, Output 230V +/-1%, AC with Bypass supply, Battery Bank, ACDB (Incomer 32A DP MCB & Outgoing 10 Nos. 6A to 10A DP MCB) and 2.0 hrs. Battery backup (VRLA, 12V) and battery capacity shall not be less than 13.0 KVAh (where KVAH = battery AH x 12 V x No. of Batteries). As per enclosed Specification, Block diagram & Data sheet and shall be complete in all respect. Including All interconnecting cables among UPS, Rectifier, battery stand, ACDB etc (30 mtr shall be considered between battery bank and UPS panel, 30 mtr cable shall be considered between ACDB and UPS panel. |
| 277 | Supply of following sizes of GI With Class B (Medium Duty, For straight route length) / HDPE Pipe (for bend route) in required length, supply of clamps, small iron structures, spacersplugs, sealent etc. and materials complete as per approved drawingsand directions of Engineer-In-Charge. |
| 278 | 50 mm NB |
| 279 | 100 mm NB |
| 280 | Supply of following Hot Dip Galvanized Ladder/Perforated Typecable trays (as per IS 2629) including bends, tee, crosses,horizontal and vertical splices along with cable tray cover(Wherever required for Asthetic look ) etc. as required including supply of all G.I hardwares, all labour and material as required as per standard drawings, specification and direction ofEngineer-in-charge |
| 281 | Perforated type, made from 50mm height and 2.5 mm thick sheet steel & galvanized (86 microns) of following sizes. |
| 282 | 150mm wide |
| 283 | 300mm wide |
| 284 | Erection Material |
| 285 | Supply of MS base frame support for switch gear and bracket for misc. electrical equipment,cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, supply of necessary anchor bolts and grouting etc supply of paints applying one coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including supply of all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge. |
| 286 | For Daughter Booster Station/ DCU/On-Line |
| 287 | Supply of the following including the supply of necessary clamp, bolts, rawl plugs etc. breaking and making good of walls, if required , and including all labour and materials complete as per directions of Engineer-In-Charge, applicable standards and Indian Electricity rules. |
| 288 | Shock hazard charts complete with frame and glass |
| 289 | First Aid Boxes |
| 290 | Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark , Discharge horn with bend & wall fixing Bracket With Mfg. Test certificate |
| 291 | Caution boards (Danger, High Volatage) including supply of necessary clamps, bolts and other hardware. |
| 292 | Single Line Diagram complete in glass frame. |
| 293 | Supply ofInsulating Mats 11kV grade (as per IS:15652 - 2006) of 1000mm width, required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per applicable Indian or International standards and Indian Electricity Rules. |
| 294 | Supply of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays and misc. electrical switchgear including all labour and materials complete as required and as per directions of Engineer-In-Charge. |
| 295 | For Daughter Booster Station/ DCU/On-Line |
| 296 | Telephone & LAN |
| 297 | Supply of telephone sockets(Piano reed Type) in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required. |
| 298 | Supply of LAN sockets in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required. |
| 299 | Supply of 2 pairs,0.61mm,Telephone Cable/Wire, includingaccessories etc as required. |
| 300 | Supply of UTP cable (CAT 6), Make : D Link/Amp/Lucent |
| 301 | Supply for Construction of Cable pit with pit cover (SFRC cover HD-20 of IS-12592) including civil works repair, concrete wall/brick wall & its materials, cable conduits interface & its water sealing, cable support structure including all labour and materials complete in all aspect as per approved drawings and directions of Engineer-In-Charge. |
| 302 | 500X500(of inside clearance)X 600(Depth) |
| 303 | 750X750(of inside clearance)X800(Depth) |
| 304 | ELECTRICAL WORKS (ERECTION) |
| 305 | ERECTION |
| 306 | Erection, Testing and Commissioning of power distribution board (PDB) and Lighting Distribution Board (LDB) : |
| 307 | 415 V, 36 KA single front type indoor PDB to receive input power consisting ofbus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/23VM/05/E9/E/1081A & as per standard Specification.Single incomer of125Amp (with Single phase preventer & VMR) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) .Outgoing with 01 no. 80 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE).Outgoing with 01 no. 63 Amp TPN MCCB(with TM based O/C,S/C & E/F RELASE).Outgoing with 03 nos. 32 Amp TPN MCCB(with TM based O/C & S/CRELASE).Outgoing with 3 nos. 40A Fuse and 3 nos. 10A DP MCBwith Timer(24Hrs) Auto/Mannual. Outgoing with 3 nos. 40A Fuse and 3 nos. 10A DP MCBwithout Timer. |
| 308 | 415 V, 36 KA single front type indoor PDB to receive input power consisting ofbus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/23VM/05/E9/E/1081B & as per standard Specification.Single incomer of 100Amp (with Single phase preventer & VMR) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) .Outgoing with 03 nos. 32 Amp TPN MCCB(with TM based O/C & S/CRELASE).Outgoing with 3 nos. 40A Fuse and 3 nos. 10A DP MCBwith Timer(24Hrs) Auto/Mannual.Outgoing with 3 nos. 40A Fuse and 3 nos. 10A DP MCBwithout Timer. |
| 309 | Poly Carbonate enclosure IP65 Power Distribution Board (PDB), Distribution Panel :415V, 36 KA single front, floor mounted, modular type, indoor/outdoor application, consisting ofCu bus bar, cable termination, flameproof LCS, etc. including all labour and materials with operating mechanism, all accessories, erection & commissioning spare,etc., complete in all respects as specified in technical specification, data sheet & tender SLD (No. MEC/23VM/05/E9/E/1081C). Dimension shall be limited to 1800mm(H) X 1800mm(W) X 400mm(D).Panel shall be made of polycarbonate with glass fiber rienforced. Panel shall be environment friently, UV resistannt, recyclable, halogen & silicon free, anticorrosive and anti acid. Panel shall be fire retardant in accordance IEC 60695-2-11. It shall be tested at glow wire test for 960 deg C. Single In-comer of 125 Amp (with Single phase preventer ) 4P MCCB (with Micro processor based O/C,S/C & E/F RELEASE WITH LSIG & SHUNT TRIP) with contactor and interlock etcOutgoing with 01 ns. 80 Amp TPN MCCB(with TM based O/C,S/C & E/F RELASE) for Booster CompressorOutgoing with 01 no. 63 Amp TPN MCCB(with TM based O/C,S/C & E/F RELASE).Outgoing with 03 nos. 32 Amp TPN MCCB(with TM based O/C & S/C& E/F RELASE) for UPS and Static Bypass.Outgoing with 3 nos. 40A Fuses and 3 nos. 10A DP MCBwith Timer(24Hrs) Auto/Mannual Outgoing with 3 nos. 40A Fuses and 3 nos. 10A DP MCBwithout Timer |
| 310 | Poly Carbonate enclosure IP65 Power Distribution Board (PDB), Distribution Panel :415V, 36 KA single front, floor mounted, modular type, indoor/outdoor application, consisting ofCu bus bar, cable termination, flameproof LCS, etc. including all labour and materials with operating mechanism, all accessories, erection & commissioning spare,etc., complete in all respects as specified in technical specification, data sheet & tender SLD (No. MEC/23VM/05/E9/E/1081D). Dimension shall be limited to 1800mm(H) X 1800mm(W) X 400mm(D).Panel shall be made of polycarbonate with glass fiber rienforced. Panel shall be environment friently, UV resistannt, recyclable, halogen & silicon free, anticorrosive and anti acid. Panel shall be fire retardant in accordance IEC 60695-2-11. It shall be tested at glow wire test for 960 deg C. Single In-comer of 100 Amp (with Single phase preventer ) 4P MCCB (with Micro processor based O/C,S/C & E/F RELEASE WITH LSIG & SHUNT TRIP) with contactor and interlock etcOutgoing with 03 nos. 32 Amp TPN MCCB(with TM based O/C & S/C& E/F RELASE) for UPS and Static Bypass.Outgoing with 3 nos. 40A Fuse and 3 nos. 10A DP MCBwith Timer(24Hrs) Auto/Mannual Outgoing with 3 nos. 40A Fuse and 3 nos. 10A DP MCBwithout Timer |
| 311 | Poly Carbonate enclosure IP65 Power Distribution Board (PDB), Distribution Panel :415V, 36 KA single front, floor mounted, modular type, indoor/outdoor application, consisting ofCu bus bar, cable termination etc. including all labour and materials with operating mechanism, all accessories, erection & commissioning spare,etc., complete in all respects as specified in technical specification, data sheet & tender SLD (No. MEC/23VM/05/E9/E/1081E). Dimension shall be limited to 1800mm(H) X 1800mm(W) X 400mm(D).Panel shall be made of polycarbonate with glass fiber rienforced. Panel shall be environment friently, UV resistannt, recyclable, halogen & silicon free, anticorrosive and anti acid. Panel shall be fire retardant in accordance IEC 60695-2-11. It shall be tested at glow wire test for 960 deg C. Dual In-comer of 63/63 Amp (with Single phase preventer ) 4P MCCB (with Micro processor based O/C,S/C & E/F RELEASE WITH LSIG & SHUNT TRIP) with contactor and interlock etcOutgoing with 02 nos. 32 Amp TPN MCCB(with TM based O/C & S/C& E/F RELASE) for UPS and Static Bypass.Outgoing with 1 no. 40A Fuse and 3 nos. 10A DP MCBwith Timer(24Hrs) Auto/Mannual Outgoing with 1 no. 40A Fuse and 3 nos. 10A DP MCBwithout Timer |
| 312 | Outdoor type, Microprocessor based MCCB encased with dust & weather proof with following rating for mounting on wall or pedestal. 125A, 415V, 4P AC23 and suitable for termination of 3.5 x 120/95 sq.mm A2XFY cable on incomer terminals andoutgoing terminals.Enclosure shall be made of polycarbonate with glass fiber rienforced. Panel shall be environment friently, UV resistannt, recyclable, halogen & silicon free, anticorrosive and anti acid. Panel shall be fire retardant in accordance IEC 60695-2-11. It shall be tested at glow wire test for 960 deg C. |
| 313 | Floor mounted sheet steel APFC Panel of 10KVAR capacitor bank in steps of 4x2.5 KVAR capacitors consisting of bus bar chamber, cable alley incoming (MCCB), outgoing feeder (MCBs) as specified in tender specification. |
| 314 | Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 125A, 415V, 4 Pole AC-23 duty and suitable for termination of 3.5CX120/95/50 sq.mm A2XFY cable on incomer terminals and outgoing terminals with On, Off, Trip, RYB Indication, Voltmeter & Ammeter etc. |
| 315 | Erection, Testing and Commissioning includingpacking and forwarding, transportation, delivery at storage, of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043. |
| 316 | Earth Pits- GI PIPE Electrode with 6 mm thick chequered plate cover |
| 317 | Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover |
| 318 | GI Strip (50X6) mm |
| 319 | GI Strip (25X3) mm |
| 320 | GI lightning rod 25 mm dia. 1800 mm long including Erection, Testing and Commissioning of all hardware bare copper rope labour etc. complete as per approved drawings, specifications and directions of Engineer-In-Charge. |
| 321 | Arrangement for Earthing of LCV with Flexible green Cu wire (10 sqmm of 30 Meter length) ,Clamp (includingbolting arrangement) ,Flexible PVC and other item etc. |
| 322 | Laying, Testing and Commissioning includingpacking and forwarding, transportation, delivery at storage, of the 1.1kV grade XLPE insulated, PVC sheathed, FRLS power and control cables (conforming to IS:7098 and specification) of following sizes in trenches/ excavated under ground trench /trays, pulling through pipes and its proper sealing, cutting of paved area, roads etc. |
| 323 | 3.5x 95 mm2 A2XFY |
| 324 | 3.5x 50 mm2 A2XFY |
| 325 | 4x10 mm2 2XWY |
| 326 | 4x 6 mm2 2XWY |
| 327 | 4x 2.5 mm2 2XWY |
| 328 | Erection, Testing and Commissioning includingpacking and forwarding, transportation, delivery at storage of lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects. |
| 329 | Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear Model no. FLPW-1095 of Baliga make or equivalent) |
| 330 | Erection, Testing and Commissioning of Integral flame proof Flood Light fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire Baliga make or equivalent) |
| 331 | Street lighting pole 6mtr high GI octagonal pole (Type BOP-6030 of Bajaj make or equivalent) complete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing (MEC/SD/05/E9/77/04) & specification (MEC/TS/05/E9/077B). |
| 332 | Erection, Testing and Commissioning OF DISTRIBUTION TRANSFORMER |
| 333 | Erection, Testing and Commissioning includingpacking and forwarding, transportation, delivery at storageto site of 11 kv/433 V outdoor type,3Ph,50Hz,copper wound, Dyn11, ONAN distribution transformer complete with all accessories as per REC specification 11/1976 and/or IS 2026/1180. and latest amendments there of and first oil filled. Termination arrangement for HV side : HT bushing & LV side Cable end box/Terminal box of following rating (Make of Transformershall be approved from State Electricity Board/MECON.) |
| 334 | 63KVA |
| 335 | 25KVA |
| 336 | Erection, Testing and Commissioning of all the items listed at (Sl. No. 34to 37 below)all miscellaneous materials etc as required to complete the HT & LT installation as per the tender. (All electrical equipments shall be approved from State Electricity Board/MECON.) |
| 337 | Double pole Structure with MS joist ISMB 200 x 100 mm, 9 m long complete with 100 x 50 mm MS channels of required length and size ;11 kV3 Ph. horizontal Gang operated Air Break switch, DO fuse, lightning arrestors of suitable ampere rating;pin insulators, disc insulators, operating rod, handle, locking arrangement, copper wire for jumper connection, stay set complete with all accessories etc as required inclusive of paint (two coats of primer & twocoats of final aluminum paint) and concrete foundation. |
| 338 | Erection, Testing and Commissioning,of 11 kV, ACSR weasel conductor as required for stringing between State Electricity Board Double pole and consumer double pole structures. |
| 339 | Chain link fencing of (height 2.5 m) for the sub station area with ISA 50 x 50 x 6 mm angle and 4 mm thick welded wire mesh and 1 no. gate ( 3x3 mtr.) complete with all material, welding and labour etc(20 mtrs/set). |
| 340 | 40 mm blue granite metal for spreading in the fenced area . |
| 341 | Erection, Testing and Commissioning of point wiring as per details in construction drawing & specificationincludesPVC conduits in ceiling, complete wiring including Wiring for main/ submain from DBs to switchboard and from switchboard to light/power points with 6/4/2.5/1.5 sq.mm. FR PVC insulated copper conductor multi starnd wire in PVC conduit in recess/ trench as required, switch boxes & switches (ANCHOR ROMA make or equivalent) for following items- |
| 342 | Light Point |
| 343 | Surface/ recess mounted LED light fixrure with LED lamp (type LCTL-36 -CDL of CG make or equivalent). |
| 344 | Socket outlet (5/15 Amp combination) of ANCHOR ROMA make or equivalent |
| 345 | Ceiling fan with electronic regulator ( Energy efficent, 50W, 1200 mm sweep) |
| 346 | UPS SYSTEM |
| 347 | Design, Erection, Testing and Commissioning, packing, forwarding, delivery by equipment supplier at site including commissioning spares as requiredof UPS systems as per specification, block diagram and following rating : |
| 348 | 3KVA, 230 V Single phase, 50 Hz, single industrial type, UPS system suitable for input Power Erection, Testing and Commissioning voltage of 320V-460V-TPN with healthy single-Phase Selection, Output 230V +/-1%, AC with Bypass Erection, Testing and Commissioning, Battery Bank, ACDB (Incomer 32A DP MCB & Outgoing 10 Nos. 6A to 10A DP MCB) and 2.0 hrs. Battery backup (VRLA, 12V) and battery capacity shall not be less than 13.0 KVAh (where KVAH = battery AH x 12 V x No. of Batteries). As per enclosed Specification, Block diagram & Data sheet and shall be complete in all respect. Including All interconnecting cables among UPS, Rectifier, battery stand, ACDB etc (30 mtr shall be considered between battery bank and UPS panel, 30 mtr cable shall be considered between ACDB and UPS panel. |
| 349 | Erection, Testing and Commissioning of following sizes of GI With Class B (Medium Duty, For straight route length) / HDPE Pipe (for bend route) in required length, Erection, Testing and Commissioning of clamps, small iron structures, spacersplugs, sealent etc. and materials complete as per approved drawingsand directions of Engineer-In-Charge. |
| 350 | 50 mm NB |
| 351 | 100 mm NB |
| 352 | Erection, Testing and Commissioning of following Hot Dip Galvanized Ladder/Perforated Typecable trays (as per IS 2629) including bends, tee, crosses,horizontal and vertical splices along with cable tray cover(Wherever required for Asthetic look ) etc. as required including Erection, Testing and Commissioning of all G.I hardwares, all labour and material as required as per standard drawings, specification and direction ofEngineer-in-charge |
| 353 | Perforated type, made from 50mm height and 2.5 mm thick sheet steel & galvanized (86 microns) of following sizes. |
| 354 | 150mm wide |
| 355 | 300mm wide |
| 356 | Erection Material |
| 357 | Erection, Testing and Commissioning of MS base frame support for switch gear and bracket for misc. electrical equipment,cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, Erection, Testing and Commissioning of necessary anchor bolts and grouting etc Erection, Testing and Commissioning of paints applying one coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including Erection, Testing and Commissioning of all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge. |
| 358 | For Daughter Booster Station/ DCU/On-Line |
| 359 | Erection, Testing and Commissioning of the following including the Erection, Testing and Commissioning of necessary clamp, bolts, rawl plugs etc. breaking and making good of walls, if required , and including all labour and materials complete as per directions of Engineer-In-Charge, applicable standards and Indian Electricity rules. |
| 360 | Shock hazard charts complete with frame and glass |
| 361 | First Aid Boxes |
| 362 | Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark , Discharge horn with bend & wall fixing Bracket With Mfg. Test certificate |
| 363 | Caution boards (Danger, High Volatage) including Erection, Testing and Commissioning of necessary clamps, bolts and other hardware. |
| 364 | Single Line Diagram complete in glass frame. |
| 365 | Erection,Laying and pasting ofInsulating Mats 11kV grade (as per IS:15652 - 2006) of 1000mm width, required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per applicable Indian or International standards and Indian Electricity Rules. |
| 366 | Erection, Testing and Commissioning of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays and misc. electrical switchgear including all labour and materials complete as required and as per directions of Engineer-In-Charge. |
| 367 | For Daughter Booster Station/ DCU/On-Line |
| 368 | Telephone & LAN |
| 369 | Erection, Testing and Commissioning of telephone sockets(Piano reed Type) in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required. |
| 370 | Erection, Testing and Commissioning of LAN sockets in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required. |
| 371 | Erection, Testing and Laying of 2 pairs,0.61mm,Telephone Cable/Wire, includingaccessories etc as required. |
| 372 | Erection, Testing and Laying of UTP cable (CAT 6), Make : D Link/Amp/Lucent |
| 373 | Construction of Cable pit with pit cover (SFRC cover HD-20 of IS-12592) including civil works repair, concrete wall/brick wall & its materials, cable conduits interface & its water sealing, cable support structure including all labour and materials complete in all aspect as per approved drawings and directions of Engineer-In-Charge. |
| 374 | 500X500(of inside clearance)X 600(Depth) |
| 375 | 750X750(of inside clearance)X800(Depth) |
| 376 | All works relating to statutory approvals of the installation from competent authority like Electrical Inspectorate, CEA, DGMS, SEB etc. including carrying out of all required modifications in design / Manufacturer / Installation to meet the requirement of Indian Electricity rules and other statutory regulations in force, carrying out necessary paper work and liasion with the authorities to obtain all necessary clearances for charging of installation as per relevant national standards for Mother CNG station. However the official fees towards the approvals shall be reimbursed by the client. |
| 377 | Total Amountexcluding GST |
| 378 | GST (CGST & SGST / UTGST or IGST) @ 18% of Net Total Amount mentioned at Sl. No.377 above. (Enter rate of applicable GST) |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail