}

Corrigendum E-Nit For Supply Of Misc. Electric Items Including Led Lights, Fans, Geysers And Heating Appliances Etc Of Different To Smvdsb For A Period Of 01 Yr., F.O.R. Es, Banganga, Katra , Misc. Electric Items And Led Lights Of Different Ratings (For B, Katra-Jammu And Kashmir

Shri Mata Vaishno Devi Shrine Board has published Corrigendum E-Nit For Supply Of Misc. Electric Items Including Led Lights, Fans, Geysers And Heating Appliances Etc Of Different To Smvdsb For A Period Of 01 Yr., F.O.R. Es, Banganga, Katra , Misc. Electric Items And Led Lights Of Different Ratings (For B. Submission Date for this Tender is 09-07-2024. MCCB Tenders in Katra Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

44039343
Corrigendum E-Nit For Supply Of Misc. Electric Items Including Led Lights, Fans, Geysers And Heating Appliances Etc Of Different To Smvdsb For A Period Of 01 Yr., F.O.R. Es, Banganga, Katra , Misc. Electric Items And Led Lights Of Different Ratings (For B
Tender
Indian
Jammu And Kashmir
Katra
09-07-2024

Tender Details

corrigendum E-Nit For Supply Of Misc. Electric Items Including Led Lights, Fans, Geysers And Heating Appliances Etc Of Different To Smvdsb For A Period Of 01 Yr., F.O.R. Es, Banganga, Katra , Misc. Electric Items And Led Lights Of Different Ratings (For Brand / Make Refer Bid Document) , Modular Angle Holder, Color: Ivory. Material: Polycarbonate With Brass Metal Ring , Modular Pendant Holder (6A-240V) , Modular Batten Holder, Color: Ivory. Material: Polycarbonate With Brass Metal Ring , Ceiling Rose , Combined Switch Socket 5/15 Amp (Ss Combined) , P/T Switch 05/06 Amp. , P/T/ Switch 15/16 Amp , 3/5 Pin Socket 5 Amp , 3/5 Pin Socket 15/16 Amp , 3 Pin Top 05/06 Amp , 3 Pin Top 15/16 Amp , Electronic Type Regulator Step Up Type (Switch Type) , Electronic Type Regulator Step Up Type (Socket Type) , Bakelite Sheet 5X 5 , Bakelite Sheet 8X 5 , Bakelite Sheet 9X 11 , Bakelite Sheet 11X 13 , Pvc Tape Roll , Cord Less Bell , Din Dong Bell , Geyser Element Triangle Type 1.5 Kw ( Big Base) , Geyser Element Triangle Type 1.5 Kw ( Small Base) , Thermostat For Geyser 11 , Thermostat For Geyser 7 , Modular Box 18 Way. (Size : 142Mm X 230Mm) , Modular Box 16 Way. (Size : 142Mm X 230Mm) , Modular Box 12 Way. (132Mm X 207Mm) , Modular Box 8 Way. (79Mm X 230Mm) , Modular Box 6Way (79Mm X 207Mm) , Modular Box 4Way (79Mm X 135Mm) , Modular Box 3Way (79Mm X 99Mm) , Modular Box 2Way (79Mm X 75Mm) , Modular Box 2X4way , Modular Plate 18 Way. 260X154mm , Modular Plate 16 Way (260X154mm) , Modularplate 12 Way (220X154mm) , Modular Plate 8 Way (260X90mm) , Modular Plate6way (220X90mm) , Modular Plate 4Way (146X90mm) , Modular Plate 3Way (118X90mm) , Modular Plate 2Way (94X90mm) , Modularplate 2X4way , Modular Plate 18 Way (260X90mm) , Modular Plate16way (220X90mm) , Modular Plate12way (220X90mm) , Modular Plate 8Way (146X90mm) , Modular Plate 6Way (118X90mm) , Modular Plate 4Way (94X90mm) , Modular Plate 3Way , Modular Plate 2 Way , Modularplate 2X4way , Modular Plate 18 Way (260X90mm) , Modular Plate16way (220X90mm) , Modular Plate12way (220X90mm) , Modular Plate 8Way (146X90mm) , Modular Plate 6Way (118X90mm) , Modular Plate 4Way (94X90mm) , Modular Plate 3Way , Modular Plate 2 Way , Modularplate 2X4way , Modular Switch 6-10 Amp One Way Confirming To Is 3854 : 1997 (Updated As On Date) Voltage Rating: 240V S Nature Of Supply: 50Hz Ambient Operating Temp: -5O C To +60O , Modular Switch 16-25 Amp One Way Confirming To Is 3854 : 1997 (Updated As On Date) Voltage Rating: 240V S Nature Of Supply: 50Hz Ambient Operating Temp: -5O C To +60O , Modular Socket 6-10 Amp Voltage Rating: 240V S Nature Of Supply: 50Hz Ambient Operating Temp: -5O C To +60O,All Sockets Complies To Is1293-2005 (Updated As On Date) , Modular Socket 16-25 Amp Voltage Rating: 240V S Nature Of Supply: 50Hz Ambient Operating Temp: -5O C To +60O , Modular Bell Push Switch One Way , Modular Blank Plate , Modular Fan Regulatorsocket Type , Modular Fan Regulatorswitch Type , Modular Data Socket , Modular Tv Socket , Modular Telephone Socket , Modular Switch 6-10 Amp One Way Confirming To Is 3854 : 1997 (Updated As On Date) Voltage Rating: 240V S Nature Of Supply: 50Hz Ambient Operating Temp: -5O C To +60O , Modular Switch 16-25 Amp One Way Confirming To Is 3854 : 1997 (Updated As On Date) Voltage Rating: 240V S Nature Of Supply: 50Hz Ambient Operating Temp: -5O C To +60O , Modular Socket 6-10 Amp Voltage Rating: 240V S Nature Of Supply: 50Hz Ambient Operating Temp: -5O C To +60O,All Sockets Complies To Is1293-2005 (Updated As On Date) , Modular Socket 16-25 Amp Voltage Rating: 240V S Nature Of Supply: 50Hz Ambient Operating Temp: -5O C To +60O , Modular Bell Push Switch One Way , Modular Blank Plate , Modular Fan Regulatorsocket Type , Modular Fan Regulatorswitch Type , Modular Data Socket , Modular Tv Socket , Modular Telephone Socket , Modular Switch 6-10 Amp One Way Confirming To Is 3854 : 1997 (Updated As On Date) Voltage Rating: 240V S Nature Of Supply: 50Hz Ambient Operating Temp: -5O C To +60O , Modular Switch 16-25 Amp One Way Confirming To Is 3854 : 1997 (Updated As On Date) Voltage Rating: 240V S Nature Of Supply: 50Hz Ambient Operating Temp: -5O C To +60O , Modular Socket 6-10 Amp Voltage Rating: 240V S Nature Of Supply: 50Hz Ambient Operating Temp: -5O C To +60O,All Sockets Complies To Is1293-2005 (Updated As On Date) , Modular Socket 16-25 Amp Voltage Rating: 240V S Nature Of Supply: 50Hz Ambient Operating Temp: -5O C To +60O , Modular Bell Push Switch One Way , Modular Blank Plate , Modular Fan Regulatorsocket Type , Modular Fan Regulatorswitch Type , Modular Data Socket , Modular Tv Socket , Modular Telephone Socket , Mcb Distribution Box 16 Way Double Door Ip-43 Confirming To Is-8623 , Mcb Distribution Box 12 Way Double Door Ip-43 Confirming To Is-8623 , Mcb Distribution Box 8 Way Double Door Ip-43 Confirming To Is-8623 , Mcb Distribution Box 4 Way Double Door Ip-43 Confirming To Is-8623 , Mcb Distribution Box 2 Wayip-43 Confirming To Is-8623, , Tpn Mcb, Distribution Box 4 Way (4+12 ) Double Door Confirming To Is-8623 Is/Iec 60898-1, Ambient Operating Temp: -5O C To +60O , Tpn Mcb, Distribution Box 6 Way (4+18 ) Double Door Confirming To Is-8623 Is/Iec 60898-1 Ambient Operating Temp: -5O C To +60O , Tpn Mcb, Distribution Box 8 Way (4+24) Double Door, Confirming To Is-8623 Is/Iec 60898-1 Ambient Operating Temp: -5O C To +60O , Tpn Mcb, Distribution Box 12 Way (4+36 ) Double Door, Confirming To Is-8623 Is/Iec 60898-1 Ambient Operating Temp: -5O C To +60O , Mcb 6-32 Amp (C-Curve) Conforms To Is:8828-96, Iec60898, Breaking Capacity :10Ka Ambient Operating Temp: -5O C To +60O , Spn 32 Amp (C-Curve) Breaking Capacity: 10Ka Iec 60947-(Updated As On Date) Operating Voltage: 240V/415Ac, 60 V-Dc Per Pole, Ambient Operating Temp: -5O C To +60O , Spn 40 Amp (C-Curve) Breaking Capacity : 10Ka Iec 60947-(Updated As On Date) Operating Voltage: 240V/415Ac, 60V-Dc Per Pole Ambient Operating Temp: -5O C To +60O , Spn 63 Amp (C-Curve) Breaking Capacity: 16Ka Iec 60947-(Updated As On Date) Operating Voltage: 240V/415Ac, 60 V-Dc Per Pole Ambient Operating Temp: -5O C To +60O , Isolator40 Amp(C-Curve) Iec 60947-(Updated As On Date) Operating Voltage: 240V/415Ac, 60 V-Dc Per Pole Ambient Operating Temp: -5O C To +60O , Isolator 63 Amp(C-Curve) Iec 60947-(Updated As On Date) Operating Voltage: 240V/415Ac, 60 V-Dc Per Pole Ambient Operating Temp: -5O C To +60O , Tpn 63 Amp(C-Curve) Iec 60947-(Updated As On Date) Operating Voltage: 240V/415Ac, 60 V-Dc Per Pole Ambient Operating Temp: -5O C To +60O , Tpn 100 Amp(C-Curve) Iec 60947-(Updated As On Date) Operating Voltage: 240V/415Ac, 60 V-Dc Per Pole Ambient Operating Temp: -5O C To +60O , Tpn 32 Amp(C-Curve) Iec 60947-(Updated As On Date) Operating Voltage: 240V/415Ac, 60 V-Dc Per Pole Ambient Operating Temp: -5O C To +60O , Ictp 63 Amp , Ictp 100 Amp , Ictp 200 Amp , Mccb 63 Amp, 16 Ka Four Pole. Confirms To Iec-60947(Update As On Date), Operating Voltage: 240V/415Ac, 60 V-Dc Per Pole, Breaking Capacity: 16Ka Ics=100% Icu, With Company Made Spreaders , Mccb 200 Amp, 25 Ka Four Pole. Confirms To Iec-60947(Update As On Date), Operating Voltage: 240V/415Ac, 60 V-Dc Per Pole, Breaking Capacity: 16Ka With Company Made Spreaders , Mccb 100 Amp, 16 Ka Four Pole. Confirms To Iec-60947(Update As On Date), Operating Voltage: 240V/415Ac, 60 V-Dc Per Pole, Breaking Capacity: 16Ka Ics=100% Icu,With Company Made Spreaders , Mccb 400 Amp, 50 Ka Four Pole. Confirms To Iec-60947(Update As On Date), Operating Voltage: 240V/415Ac, 60 V-Dc Per Pole, Breaking Capacity: 16Ka Ics=100% Icu,With Company Made Spreaders , Mccb 63 Amp, 10 Ka Three Pole. Confirms To Iec-60947(Update As On Date), Operating Voltage: 240V/415Ac, 60 V-Dc Per Pole, Breaking Capacity: 16Ka Ics=100% Icu, With Company Made Spreaders , Mccb 200 Amp, 25 Ka Three Pole. Confirms To Iec-60947(Update As On Date), Operating Voltage: 240V/415Ac, 60 V-Dc Per Pole, Breaking Capacity: 16Ka Ics=100% Icu,With Company Made Spreaders , Mccb 100 Amp, 16 Ka Three Pole. Confirms To Iec-60947(Update As On Date), Operating Voltage: 240V/415Ac, 60 V-Dc Per Pole, Breaking Capacity: 16Ka: Ics=100% Icu,With Company Made Spreaders , Mccb 400 Amp, 50 Ka Three Pole. Confirms To Iec-60947(Update As On Date), Operating Voltage: 240V/415Ac, 60 V-Dc Per Pole, Breaking Capacity: 16Ka Ics=100% Icu, With Company Made Spreaders , Mccb 630 Amp 50Ka, Three Pole. Confirms To Iec-60947(Update As On Date), Operating Voltage: 240V/415Ac, 60 V-Dc Per Pole, Breaking Capacity:10 Kaics=100% Icu, With Company Made Spreaders , Mccb 630 Amp 50Ka, Three Pole Confirms To Iec-60947(Update As On Date), Operating Voltage: 240V/415Ac, 60 V-Dc Per Pole, Breaking Capacity: 16Ka Ics=100% Icu ,With Company Made Spreaders , Change Over Switch 63 Amp Three Phase Side Handle, Conforms To Is: 13947 Part - 1 &3, Iec: 60947 Part - 1 &3. Crca Sheet, Nine Tank Epoxy Powder Coated Enclosure , Change Over Switch 100 Amp Three Phase Side Handle Conforms To Is: 13947 Part - 1 &3, Iec: 60947 Part - 1 &3. Crca Sheet, Nine Tank Epoxy Powder Coated Enclosure , Change Over Switch 200 Amp Three Phase Side Handle Conforms To Is: 13947 Part - 1 &3, Iec: 60947 Part - 1 &3. Crca Sheet, Nine Tank Epoxy Powder Coated Enclosure , Change Over Switch 63 Amp Three Phasebox Type Conforms To Is: 13947 Part - 1 &3, Iec: 60947 Part - 1 &3. Crca Sheet, Nine Tank Epoxy Powder Coated Enclosure , Change Over Switch 100 Amp Three Phasebox Type Conforms To Is: 13947 Part - 1 &3, Iec: 60947 Part - 1 &3. Crca Sheet, Nine Tank Epoxy Powder Coated Enclosure , Change Over Switch 200 Amp Three Phasebox Type Conforms To Is: 13947 Part - 1 &3, Iec: 60947 Part - 1 &3. Crca Sheet, Nine Tank Epoxy Powder Coated Enclosure , Fan Box , Junction Box , Pvc Conduit Pipe 1” 2Mm Thick , Pvc Conduit Pipe ¾ ” 2Mm Thick , Pvc Conduit Pipe1½ ” 2Mm Thick , Pvc Conduit Bend 1”2Mm Thick , Pvc Conduit Bend 1 ½ ”2Mm Thick , Pvc Conduit Bend ¾ ”2Mm Thick , Pvc Batten 1” , Pvc Batten 2” , Flexible Pipe 1” , Flexible Pipe 2” , Iron Junction Box 3” Deep 3/4 Way Heavy Duty , Iron Junction Box 1” Deep 3/4 Way Heavy Duty , Iron Fan Box 4“ Deep Heavy Duty , Iron Concealed Box 3” Deep Heavy Duty , Capacitor 36 Mfd , Capacitor 45 Mfd , Capacitor 50 Mfd , Capacitor 3.15 Mfd , 10W To 12W Led Integrated Batten 2 Feet, System Lumen Output=100Lm/W, Cct: 6500°K, Cri= 80, Sdcm=5, Pf=0.90, Surge 2.5Kv, , Warranty : Minimum - 2Years , 18W To 20W Led Integrated Batten 4 Feet, System Lumen Output=100Lm/W, Cct: 6500°K, Cri= 80, Sdcm=5, Pf=0.90, Surge 2.5Kv, Warranty : Minimum - 2Years , 12W Led Circular Ceiling Light Surface Mounted, Crca Housing Only, System Lumen Output =100-120Lm/W, Cct: 6500°K,Cri= 80,Sdcm=5, Thd=10%, Surge 4Kv, Pf=0.90, Ip20.. Warranty Minimum - 2 Years , 8/9W Led Circular Ceiling Light Recessed Mounted(Concealed), Pressure Die Cast Aluminum Housing Only, System Lumen Output =100-120Lm/W, Cct: 6500°K,Cri= 80,Sdcm=5, Thd=10%, Surge 2.5Kv, Pf=0.90, Ip20. Warranty Minimum - 2 Years , 5/6W Led Circular Ceiling Light Recessed Mounted (Concealed), Pressure Die Cast Aluminum Housing Only, System Lumen Output = 100-120Lm/W, Cct: 6500°K,Cri= 80,Sdcm=5, Thd=10%, Surge 2.5Kv, Pf=0.90, Ip20.. Warranty Minimum - 2 Years , 36W Led 2 Feet X 2 Feet Recessed Mounted, System Lumen Output:= 100-120Lm/W, Cct: 6500°K,Cri= 80,Thd=30%, Surge 2.5Kv, Pf=0.90, Ip20. Warranty Minimum - 2 Years , Led Lamp 9W To 10W, System Lumen Output = 80-100Lm/W, Cct: 6500°K, Cri = 80, Warranty: Minimum 2 Years , Led Lamp 15W To 17W, System Lumen Output = 80-100Lm/W, Cct: 6500°K, Cri = 80, Warranty: Minimum 2 Years , Led Lamp 5W To 7W, System Lumen Output = 80-100Lm/W, Cct: 6500°K, Cri = 80, Warranty: Minimum 2 Years , 70W To 72W Led Street Light, Pressure Die Cast Aluminum Housing Only, System Lumen Output:= 120Lm/W, Cct: 5700-6500°K,Cri= 80,Thd=10%, Surge 4Kv, Pf=0.95, Ip66, Warranty Minimum - 2 Years , 60/70W Led Street Light, Pressure Die Cast Aluminum Housing Only, System Lumen Output:= 120Lm/W, Cct: 5700-6500°K,Cri= 80,Thd=10%, Surge 4Kv, Pf=0.95, Ip66, Warranty Minimum - 2 Years , 140W To 150W Led Flood Light, Pressure Die Cast Aluminum Housing Only, System Lumen Output:= 120Lm/W, Cct: 5700=6500°K,Cri= 80,Sdcm=5, Thd=10%, Surge 4Kv, Pf=0.90,Ip66. Warranty Minimum - 2 Years , 10W To 12W Led Circular Ceiling Light Recessed Mounted, Pressure Die Cast Aluminum Housing Only, System Lumen Output =100Lm/W, Cct: 6500°K,Cri= 80,Sdcm=5, Thd=10%, Surge 2.5Kv, Pf=0.90, Ip20.. Warranty Minimum - 2 Years , 18W To 20W Led Circular Ceiling Light Recessed Mounted, Pressure Die Cast Aluminum Housing Only, System Lumen Output =100Lm/W, Cct: 6500°K,Cri= 80,Sdcm=5, Thd=10%, Surge 2.5Kv, Pf=0.90, Ip20. Warranty Minimum - 2 Years , Geyser 35 Litres Type Of Geyser: Closed, Wall Mounting: Vertical Star Rating: 5 Star Pressure: 60 N/-Sq.Cm & Above. Tank: Glass Lined Warranty: 05 Years On Tanks And 02 Years On Product. , Geyser 25 Litres Type Of Geyser: Closed Wall Mounting: Vertical Star Rating: 5 Star Pressure: 60 N/-Sq.Cm & Above. Tank: Glass Lined Warranty: 05 Years On Tanks And 02 Years On Product , Geyser 15 Litres Type Of Geyser: Closed Wall Mounting: Vertical Star Rating: 5 Star Pressure: 60 N/-Sq.Cm & Above. Tank: Glass Lined Warranty: 05 Years On Tanks And 02 Years On Product. , Energy Efficient Ceiling Fan (48 Inches),1200Mm Wh Warranty: Two Years , Wall Mounting Fan 16” (400 Mm) Type Of Fan Mounting: Bracket Mounted Fan For Wall Mounting. Speed Control Mechanism: Pull Cord Or String Based Control. Number Of Speed Steps: 03, Color: White Warranty: One Year , Exhaust Fan 9”, Metal Body Heavy Duty. Warranty: One Year , Exhaust Fan 10”, Plastic Body Light Duty With Louvers Warranty: One Year , Exhaust Fan 12”, Metal Body Heavy Duty. Warranty: One Year , Exhaust Fan 18”, Metal Body Heavy Duty. Warranty: One Year , Heat Pillars Specifications: Propeller Fan (4”) 2 –Rods (1 Tube 1000W) Thermal Cut-Off Warranty: 01 Year , Heat Convector, Voltage: 230 Volts, Rated Power: 2000 Watts Frequency: 50Hz, Body Material: Stainless Steel Warranty: 01 Year

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail