| 1 | CODE NO.15.2.1: Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead - nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 2 | CODE NO.2.8.1:Earthwork in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50m - all kinds of soil |
| 3 | CODE NO. 4.1.10:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) |
| 4 | CODE NO: 4.1.11A:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:5:10 (1 cement : 5 coarse sand : 10 graded brick aggregate 40mm nominal size) |
| 5 | CODE NO: 4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) |
| 6 | CODE NO: 32.35.3.2:Constructing brick masonry open surface drain with class designation 35 in cementmortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10 cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size and 25 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 12.5 mm nominal size) for filling haunches including 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design - 25 cm drain 30 cm average depth - with brick class designation 35. |
| 7 | CODE NO: Non PSR:Constructin of intercepting chamber of the size 600x850x1100mm deep with R.C.C top slab of 100 mm thick in R.C.C 1:1:5:3 ( one cement one and half sand and three drawings, foundation in PCC 1:4:8 mix (one cement four and sand eight hard broken granite stone aggregaate of 40 mm nominal size) side wall of 23 cm thick in brick, inside and outside plastering with 20 mm thick in CM 1:3 (one cement and three sand) and making channel for house service connection in cement concrete 1:1:5:3 (one cement, one and half sand and three HBG stone aggregate of 20 mm nminal size) rendered with CM 1:3 (one cement and three sand)20 mm thick complete. conveying and fixing of circular 450 mm dia FRC manhole cover with frame of heavy duty as per IS 12592-2002(I&II) and latest revsion in accordance with CPHEEO manuals on Sewerage & Sewage treatment and relevant IS codes in cement concrete 1:1:5:3 (one cement one and half sand and three HBG stone aggregate of 20mm nominal size). The cost includes curing and testing of the intercepting chamber for its water tightness. A drop in water more than 50 mm in 24 hours shall not be permitted. The rate includes cost of Circular FRC manhole cover with frame of heavy duty of size 450mm dia, centering, shuttering and reinforcement with TMT (TISCON/VIZAG/ IISCO /SAIL/) bars, but excluding the cost of earth work excavation. |
| 8 | CODE NO: 6.1.1:Brick work with common burnt clay F.P.S.(non modular ) bricks of class designation 7.5 in foundation and plinth in – cement mortar 1:4 (1 cement : 4 coarse sand. |
| 9 | CODE NO: 6.13.2:Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level upto floor V level – cement mortar 1:4 (1 cement : 4 coarse sand) |
| 10 | CODE NO: 6.15:Extra for providing and placing in position 2 nos 6mm dia M.S.bars at every third course of half brick masonry |
| 11 | CODE NO: 5.16: Providing , hoisting and fixing upto floor five level precast reinforced cement concrete in shelves including setting in cement mortar 1:3 (1 cement : 3 coarse sand) , cost of required centering , shuttering and finishing with neat cement punning on exposed surfaces but excluding the cost of reinforcement , with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) |
| 12 | CODE NO: 5.22.7:Steel reinforcement for R.C.C.work including straightening , cutting , bending , placing in position and binding all complete upto plinth level - Thermo-Mechanically treated bars (ISI BRAND OF APPROVED MAKE) Fe - 415 or more |
| 13 | CODE NO: 13.8.3:12 mm cement plaster of mix 1:5 (1 cement : 5 fine sand) |
| 14 | CODE NO: 13.5.1:15mm cement plaster on rough side of single or half brick wall of mix - 1:4 (1 cement : 4 coarse sand |
| 15 | CODE NO: 13.9.2: cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement - 20mm cement plaster |
| 16 | CODE NO: 18.76.1: Cutting holes upto 30x30 cm in walls including making good the same – with common burnt clay F.P.S.(non - modular) brick |
| 17 | CODE NO: 17.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C.pan) with seat and lid, 10 litre low level white P.V.C. flusing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS: 7231,with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required - W.C. pan with ISI marked white solid plastic seat and lid |
| 18 | CODE NO:19.33.1: Providing and fixing on wall / column face unplasticed - PVC soil and waste pipes (type - B) conforming to IS : 13592- 1992 including jointing with seal ring conformation to IS : 5382 leaving 10mm gap for thermal expansion - single socked pipes -110mm diameter |
| 19 | CODE NO: 31.161.1F:Providing, laying and jointing UPVC pipes(Finolex / jain / Supreme / Truebore / Nandi) (0.6 Mpa)conforming to IS specification 4985 and ISI marked including transportation to the site , lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment,including cost of solvent cement,excluding UPVC specials such as bends,tees, threaded pieces,couplers,reducer,endcaps etc.,complete all as per IS and CPWD specification. - 110mm dia. |
| 20 | CODE NO: Non PSR:Providing and fixing PVC plain single equal junction to soil waste line 110x110x100 mm dia. |
| 21 | CODE NO: 19.33.1D: Providing and fixing on wall face / column face unplasticised - PVC mould fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS : 14735 – 1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - bend with door 110 mm |
| 22 | CODE NO:12.43.2:Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs , screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc., complete - 110mm |
| 23 | CODE NO: Non PSR:Providing and fixing PVC 110 mm dia terminal guard - Vent cowl. |
| 24 | CODE NO:12.42.6.2: Providing and fixing on wall face unplasticised - PVC moulded fittings /accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - shoe (plain) -110mm shoe |
| 25 | CODE NO:19.33.2:Providing and fixing on wall / column face unplasticised - PVC soil and waste pipes (type B) conforming to IS :13592 – 1992 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Single socketed pipes 75mm diameter |
| 26 | CODE NO: 12.43.1:Providing and fixing unplasticised - PVCpipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs , screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc., complete - 75mm |
| 27 | CODE NO: Non PSR:Providing and fixing PVC terminal guard -vent cowl 75mm |
| 28 | CODE NO:12.42.3.1:Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - Single tee with door - 75 x75x75mm |
| 29 | CODE NO:19.33.2C:Providing and fixing on wall / column face unplasticisd - PVC moulded fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS :14735 -1999including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Bend 75 mm |
| 30 | CODE NO: 18.9.11: Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall ) - 20mm nominal outer dia pipes |
| 31 | CODE NO:18.9.14: Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall ) - 40mm nominal outer dia pipes |
| 32 | CODE NO:18.17.3:Providing and fixing gun metal gate valve with C.I.wheel of approved quality (Screwed end) - 40mm nominal bore |
| 33 | CODE NO:13.44.1: Finishing walls with water proofing cement paint of required shade - New work (Two or more coats applied @ 3.84 kg / 10 sqm) |
| 34 | CODE NO:13.42.1:Distempering with 1st quality acrylic washable distember (ready mixed) of approved manufacutrer , of required shade and colour complete as per manufacturer \"s specification - Two or more coats on new work |
| 35 | CODE NO:11.36A: Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) , of approved make (Jhonson / Asian / Somany / Nitco) in all colours , shades of size 200 x 300 mm as approved in skirting , risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement with pigment of matching shade complete - size200x300 mm |
| 36 | CODE NO:11.39.1: Providing and laying rectified glazed ceramic flooring tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of commercial quality conforming to IS :15622 , of approved make ( Somany / Nitco / Johnson) in colours white, ivory, grey, fume red brown, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) , including grouting the joints with white cement and matching pigments etc., complete |
| 37 | CODE NO:18.58.2.1:Providing and fixing PTMT grating of approved quality and colour – rectangular type with openable cirucular lid - 150mm nominal size square 100mm diametre of theinner hinged round grating |
| 38 | CODE NO: 17.78.1: Providing and fixing CP brass health faucet of approved quality - 15 mm nominal bore |