Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exc 1.5 meters wide and not exc1.5 meters deep for pipe line, cable etc in soft/ loose soil & getting out all as specified and as directed by Engineer-in-Charge. |
| 2 | Excavation in trenches not exc 1.5 meters wide and not exc1.5 meters deep for pipe line, cable etc in hard/ dense soil/ hard standing/ metallic road & getting out all as specified and as directed by Engineer-in-Charge. |
| 3 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thickness all as specified and directed by Engineer-in-Charge. |
| 4 | Removing excavated soil from site to a distance not exc 50 meters away and depositing where directed not exc 1.5 meter from the starting point complete all as specified and as directed. |
| 5 | M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm complete and below 2 pole/ 4 pole structures and filling of ducts etc.completeall as spsecified and as directed by Engr-in-charge. Note:- For the purpose of measurement only punned thickness only will be mearsured as one unit. |
| 6 | M & L brick protection with old size sub class ‘B’brick for cable protection in trench with width equal to length of brick laid dry and flat joining each other with gape betweenadjacent brick not exceeding 10mm completeall as spsecified and as directed by Engr-in-charge. |
| 7 | Taking up or down steel tubing and connections of size 15 mmbore including cleaning for re-fixing completeall as spsecified and as directed by Engr-in-charge. |
| 8 | Taking up or down steel tubing and connections of size 20 mmbore including cleaning for re-fixing completeall as spsecified and as directed by Engr-in-charge. |
| 9 | Taking up or down steel tubing and connections of size 25 mmbore including cleaning for re-fixing completeall as spsecified and as directed by Engr-in-charge. |
| 10 | Taking up or down steel tubing and connections of size 40 mmbore including cleaning for re-fixing completeall as spsecified and as directed by Engr-in-charge. |
| 11 | Taking up or down steel tubing and connections of size 50 mmbore including cleaning for re-fixing completeall as spsecified and as directed by Engr-in-charge. |
| 12 | Taking up or down steel tubing and connections of size 80 mmbore including cleaning for re-fixing completeall as spsecified and as directed by Engr-in-charge. |
| 13 | Supply, laying & testing steel water tubing, medium grade, galvanised of size 15 mm bore ISI marked with and includingISI marked fittings such as tees, bends elbow reducer, unions, clamps etc fixed on wall / laid in trench/roof (with proper clamping arrangements) complete all as specified and as directed. |
| 14 | Supply, laying & testing steel water tubing, medium grade, galvanised of size 20 mm bore ISI marked with and includingISI marked fittings such as tees, bends elbow reducer, unions, clamps etc fixed on wall / laid in trench/roof (with proper clamping arrangements) complete all as specified and as directed. |
| 15 | Supply, laying & testing steel water tubing, medium grade, galvanised of size 25 mm bore ISI marked with and includingISI marked fittings such as tees, bends elbow reducer, unions, clamps etc fixed on wall / laid in trench/roof (with proper clamping arrangements) complete all as specified and as directed. |
| 16 | Supply, laying & testing steel water tubing, medium grade, galvanised of size 40 mm bore ISI marked with and includingISI marked fittings such as tees, bends elbow reducer, unions, clamps etc fixed on wall / laid in trench/roof (with proper clamping arrangements) complete all as specified and as directed. |
| 17 | Supply, laying & testing steel water tubing, medium grade, galvanised of size 50 mm bore ISI marked with and includingISI marked fittings such as tees, bends elbow reducer, unions, clamps etc fixed on wall / laid in trench/roof (with proper clamping arrangements) complete all as specified and as directed. |
| 18 | Supply, laying & testing steel water tubing, medium grade, galvanised of size 80 mm bore ISI marked with and includingISI marked fittings such as tees, bends elbow reducer, unions, clamps etc fixed on wall / laid in trench/roof (with proper clamping arrangements) complete all as specified and as directed. |
| 19 | Taking up CI/DI water main including all fittings with spigot & socket ends with lead/tyton joints including burning out lead joints and recovering lead for 80 mm bore pipe complete all as specified and as directed. |
| 20 | Taking up CI/DI water main including all fittings with spigot & socket ends with lead/tyton joints including burning out lead joints and recovering lead for 100 mm bore pipe complete all as specified and as directed. |
| 21 | Taking up CI/DI water main including all fittings with spigot & socket ends with lead/tyton joints including burning out lead joints and recovering lead for 150 mm bore pipe complete all as specified and as directed. |
| 22 | Taking up CI/DI water main including all fittings with spigot & socket ends with lead/tyton joints including burning out lead joints and recovering lead for 200 mm bore pipe complete all as specified and as directed. |
| 23 | Supply, laying, jointing and testing DI pipe K-9 in replacement of CI pipe of size 80 mminternal dia with spigot and socket end including tyton joints complete all as specified and directed. |
| 24 | Supply, laying, jointing and testing DI pipe K-9 in replacement of CI pipe of size 100 mminternal dia with spigot and socket end including tyton joints complete all as specified and directed. |
| 25 | Supply, laying, jointing and testing DI pipe K-9 in replacement of CI pipe of size 150 mminternal dia with spigot and socket end including tyton joints complete all as specified and directed. |
| 26 | Supply, laying, jointing and testing DI pipe K-9 in replacement of CI pipe of size 200 mminternal dia with spigot and socket end including tyton joints complete all as specified and directed. |
| 27 | M&L for DI specials such as tees, bends, collars of any sizes and radius, tapers, tail pieces caps and plug upto 200 mm bore complete all as specified and as directed by Engr-in-Charge. |
| 28 | M&L for cast iron special fittings of any size, any type ISI marked as required at site such as bends (any type, radius and angle),Taper any type, (straight, bend, increasing, decreasing or double socket etc), Tee pieces single branch. \"Y\" junction, double branch, cross (all socket or socket and spigot), collar, caps and plugs upto 150mm bore etc complete all as specified and directed by Engineer-in-Charge. |
| 29 | S&F in repair GI fittings such as reducers, tee, elbow, socket, nipple, plug, reducer socket, reducer elbow, unions and other connected accessoriesof size 15mm to 80mm bore complete all as specified and as directed by Engineer-in-charge. |
| 30 | M&L in replacement of run lead joints for cast iron pipe 80mm bore spigot & soketed/CI fittings including all jointing material required at siteincluding necessary excavation work complete all as specified and as directed by Engineer-in-charge. |
| 31 | M&L in replacement of run lead joints for cast iron pipe 100mm bore spigot & soketed/CI fittings including all jointing material required at siteincluding necessary excavation work complete all as specified and as directed by Engineer-in-charge. |
| 32 | M&L in replacement of run lead joints for cast iron pipe 150mm bore spigot & soketed/CI fittings including all jointing material required at siteincluding necessary excavation work complete all as specified and as directed by Engineer-in-charge. |
| 33 | M&L in replacement of run lead joints for cast iron pipe 200mm bore spigot & soketed/CI fittings including all jointing material required at siteincluding necessary excavation work complete all as specified and as directed by Engineer-in-charge. |
| 34 | S&F in replacement of gun metal globe or gate valve ISI marked with iron wheel head screwed both ends for 50mm bore iron pipe complete all as specified and as directed by Engineer-in-charge. |
| 35 | S&F in replacement of gun metal globe or gate valve ISI marked with iron wheel head screwed both ends for 40mm bore iron pipe complete all as specified and as directed by Engineer-in-charge. |
| 36 | S&F in replacement of gun metal globe or gate valve ISI marked with iron wheel head screwed both ends for 25mm bore iron pipe complete all as specified and as directed by Engineer-in-charge. |
| 37 | S&F in replacement of gun metal globe or gate valve ISI marked with iron wheel head screwed both ends for 20mm bore iron pipe complete all as specified and as directed by Engineer-in-charge. |
| 38 | S&F in replacement of gun metal globe or gate valve ISI marked with iron wheel head screwed both ends for 15mm bore iron pipe complete all as specified and as directed by Engineer-in-charge. |
| 39 | S&F in replacement of cast iron sluice valves, class PN-1.6, ISI marked, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets etc of 80 mm bore complete all as specified and as directed by Engineer-in-charge. |
| 40 | All as per item No 39 above but 100 mm bore pipe complete all as specified and as directed by Engr-in-Charge. |
| 41 | All as per item No 39 above but 150 mm bore pipe complete all as specified and as directed by Engr-in-Charge. |
| 42 | All as per item No 39 above but 200 mm bore pipe complete all as specified and as directed by Engr-in-Charge. |
| 43 | M&L for construction of valve pit chamber having internal dimension 120 cm x 120 cm x 120 cm (internal height) using 150mm thick PCC 1:4:8 with 40 mm graded stone aggregate in foundation, 23 cm thick brick work in cement mortar 1:4 with 15 mm thick rendering in cement mortar 1:6 all around the brick work, PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in coping including grouting mild steel frame of angle iron of size 40mm x 40mm x 6 mm thick including 8mm thick mild steel sheet cover with locking arrangement with and including 50 mmpad lock with double key arrangement, painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation work in any type of soil, returning filling in and removal of surplus soil to a distance not exc 50 mtr away and depositing where directed at level not exc 1.5 m above the starting point including demolition ofexisting valve chamber complete all as specified and directed byEngineer-in-Charge. |
| 44 | All as per item No 43 above but of size 90cm x 90cm x 90cm complete all as specified and as directed by Engr-in-Charge. |
| 45 | M&L for augering of holes in true horizontal position under road by trench less method by means of mechanical rig covering in route upto 1.5 mtr deep and not exceeding 30 mtr long for passing the water pipe lines upto 150mm bore complete all as specified and as directed by Engr-in-Charge. |
| 46 | M&L in replacement of well cap with housing clamp upto 300 mm bore pipe in two pieces having 80 mm dia hole in centre with external braket of flat iron of size 100mm X 6 mm thick complete with nuts, bolts and washers etc including welding,painting etc complete all as specified and directed by Engineer-in-Charge. |
| 47 | Material & Labour for cleaning internal portion of stone masonry/RCC underground/Semi underground water storagesump ofincluding removing fine sand/silt deposited inside the underground sump with the help of wire brushes and removing any fungus formation inside the tank, removing the waste as directed and applying one coat of snocem externally including writing work with one coat of synthetic enameled paint as per colour codefor inlet/outlet /Overflow/washout CI/GI pipes marking flow of water on pipes including painting/writing of letters of (a) date of cleaning (b) Next due date of cleaning (c) Capacity of tank. complete all as directed by Engineer-in-charge for the 50,000 Glns capacity. |
| 48 | Material & Labour for cleaning internal portion of stone masonry/RCC underground/Semi underground water storagesump ofincluding removing fine sand/silt deposited inside the underground sump with the help of wire brushes and removing any fungus formation inside the tank, removing the waste as directed and applying one coat of snocem externally including writing work with one coat of synthetic enameled paint as per colour codefor inlet/outlet /Overflow/washout CI/GI pipes marking flow of water on pipes including painting/writing of letters of (a) date of cleaning (b) Next due date of cleaning (c) Capacity of tank. Complete all as directed by Engineer-in-charge for the 25,000 Glns capacity. |
| 49 | Material and labourfor cleaning internal portion of stone masonry/RCC over head reservoirs including removing fine sand/silt deposited inside the over head reservoirs with the help of wire brushes and removing any fungus formation inside the tank, removing the waste as directed and one coat of snocem externally including writing work with one coat of synthetic enameled paint as per colour codefor inlet/outlet /Overflow/washout CI/GI pipes marking flow of water on pipes including painting/writing of letters of (a) date of cleaning (b) Next due date of cleaning (c) Capacity of tank. Complete all as directed by Engineer-in-charge for the 1,00,000 Glns capacity. |
| 50 | All as per srl item No 49here-in-before but 50,000 Glns capacity complete all as specified and as directed. |
| 51 | Surface dressing in hard/dense soil, not exceeding 15cm deep for cleaning the area by cutting the unwanted bushes/vegetation growth in and around the area oh installation/around the valve pit chamber/along the pipeline routes if reqd etc complete all as specified and as directed by Engr-in-charge. |
| 52 | Supply and fixing GI dead plate/ flanged with jointing material like packing, nuts & bolts after cutting pvc fiittings such as tees, bend including necessary exacavation required at site upto order of (3 mtr x 2 mtr x 2 mtr ) complete all as specified and directed by Engr-in-charge. |
| 53 | M&L in replacement of insulated rubber chequered sheet of size 2.00 x 1.00 mtrnot less than 19mm thick complete all as specified and as directed. |
| 54 | Supply and fix in replacement Digital water levelIndicator Device type -DDS -6 , digit display 150 mm size, direct display in digit, 230 volts Ac,50 Hzsuitable for upto 10 Mtrs, Over head tank, Alarm for upper and Lower Level Pre -adjustable, Temperature Range -5 degree C to 50 degree C, Humidity upto 95% RH , Reset push switch for silent the Alarm with ON/OFF Operation system including 4 core 0.5 sqmm copper cable complete all as specified and as directed by Engineer -in- charge. |
| 55 | S&F in replacement of cast iron NRV PN 1.6 of 150mm bore both end flanged with necessary packing materials nut, bolt & washer of suitable sizecomplete all as specified and as directed. |
| 56 | All as per item No 55 above but of 80mm bore complete all as specified and as directed. |
| 57 | All as per item No 55 above but of 100mm bore complete all as specified and as directed. |
| 58 | Supply and fixing in replacement of CI foot valve of 150mm bore both end flanged with necessary packing materials nut, bolt & washer of suitable sizecomplete all as specified and directed by Engr-in-charge. |
| 59 | All as per srl item No 58 here-in-before but of size 100mm bore dia complete all as specified and directed by Engr-in-charge. |
| 60 | Supply & fixing in replacement of valve pit cover/ Sump manhole cover/ pressure pump shade etc made out of mild steel frame with 40mmx40mmx6mm thick angle iron with and including 3.0 mm thick mild steel sheet cover with locking arrangement and painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge. |
| 61 | Supply only CDD 5000 (two components chlorine dioxide powder) CAS No 10049-04-4 conforming to ISO 9001-2015 white in colour highly soluble in water, 99.9% effective against water borne micro organisms disinfectant for chlorination of water complete all as specified and as directed. |
| 62 | Disconnecting existing defective electric motor of any make capacity of motor upto30 to 50 HP from electric mains isolating the connections, removing from foundation by unscrewing the nuts, boltsetc, discouple from pump, opening of motor for inspection in presence of Engr-in-Charge & carrying out minor repairsat site and re-assemblingthe motor afterrepair, refixing in position re-connecting same as prior to removing from foundation including replacement of nuts, boltswashers ofsuitable size, testing and commissioning complete all as specified and directed. |
| 63 | All as per item No.62 here-in-before but capacity of motor 15HP to 25HP complete all as specified and directed by Engr-in-charge. |
| 64 | All as per item No.62 here-in-before but capacity of motor upto 5HP complete all as specified and directed by Engr-in-charge. |
| 65 | Taking out old unserviceable/burnt copper winding ofmotors capacity up to 30 to 50 HP and material and labour for rewinding of electric motor ofcapacity up to 40 to 50 HP, 3 Phase with super enameled copper winding wire of suitable gauge as per existing including cleaningof rotor slots, all winding/insulation material, varnishing etc. complete and testing at site on full load after reinstallation to the full satisfaction of Engr-in-Charge, complete all as specified and as directedby Engr-In-Charge. |
| 66 | All as per item No 65 here in before but upto 15 to 25 HP,three phase,of any type & size complete all as specified and as directedby Engr-In-Charge. |
| 67 | All as per item No 65 here in before but upto 5 HP, three phase, of any type & size complete all as specified and as directedby Engr-In-Charge. |
| 68 | Taking out unserviceable terminal plate with connector and outer cover of elect motor of any make, type upto 50 HP capacity and supply & connect, testing terminal plate with connector same as per existing complete all as specified and as directed Engr-in-Charge. |
| 69 | M&L for replacement of Ball bearing of the electric motor upto 30 tO 50 HP 415 Volt as opened in item No 58 here in before complete all as directed. |
| 70 | M&L for replacement of Ball bearing of the electric motor upto 15 to 25 HP 415 Volt as opended in item No59 here in before complete all as directed. |
| 71 | M&L for replacement of Ball bearing of the electric motor upto 5 HP 3 phase / single phase as opended in item No 60 here in before complete all as directed.. |
| 72 | M&L for replacement of MS Shaft of the electric motor upto 5 HP 440 Volts in repairs dismanteled underitemNo 60 here in before complete all as directed. . |
| 73 | M&L for replacement of MS Shaft of the electric motor upto 50 HP 440 Volts in repairs dismanteled underitemNo 58 & 59 here in before complete all as directed. . |
| 74 | Taking out defective pump of any type, any make upto 30 to 50 HP by unscrewing the foundation bolts, disconnecting from water connection, and disconnecting from electric motor, opening for inspection in presence ofEngr-in-Charge and carry out minor repair at site, in case major repair/replacement of parts not possible at site, the pump shall be shifted to contractor\"s workshop on his own cost, and re-fixing, re-connecting in position, testing and commissioning complete including replacement of nuts bolts washers ass as specified and as directed by Engr-in-charge.Note :-(a)Replacement of parts includedthis item.(b) In case ofrepairs not possible at site, the motor shall be shifted to contractor’s wksp and cost of shifting to wksp and back to site included in the item rates. (c) Replacement of windings, Shaft and bearings to be measured separately. |
| 75 | All as per item 74 above but 15 to 25 HP |
| 76 | All as per item 74 above but upto 5 HP |
| 77 | M&L for replacement of unserviceable/defective mild steel shaft 5 to 50 HP centrifugal pump set of any make complete all as specified and as directed. Note:- Pump shall be taken out against item 74, 75 & 76 here in before. |
| 78 | All as per items 77 here in before but ball bearing including greasing etc complete all as specified and as directed. |
| 79 | Disconnecting electric connections from starter, disconnecting the water connections carefully by unscrewing the nuts, bolts and taking out the submersible pump set upto 10 HP ( including motor) from the well including column pipes, and submersible cable, disconnecting the pump and motor opening the pump and motor to locate the faults in presence of Engineer-in-Charge and carry out necessary repairs as directed including transporting to workshop, re-assembling the same after repair, taking down to thewell including column pipe of any dia, 10 ft long, and submersible cable which have been taken out, re-connecting all electrical and water connections as per existing complete, testing and commissioningincluding new packing materials, nuts, bolts,washers of suitable size complete all as specified and as directed. Note :- (a)Replacement of all unsv parts ofpump and motorincluded in the quoted rates of item.(b) In case ofrepairs not possible at site, the motor and pumpshall be shifted to contractor’s wksp and cost of shifting to wksp and back to site included in the quoted rates. (c) Replacement ofmotor winding measured separately. |
| 80 | Taking out old unserviceable/burnt winding from the submersible 3 phase motors up to 10 HPcapacity and M& L for rewindinig the same with insulated winding wire as per existing gauge complete including transportation to and fro as approved by Engr-in Charge and testing after repair complete all as specified and as directed. |
| 81 | S&F in replacement of GI column pipe 80mm bore meduim grade, 10 feet length, both ends flanged & drilled including cutting of grooves for submersible cable and fabrication etc complete all as specified and directed by Engr-in-charge. |
| 82 | S&F in replacement of GI column pipe 50mm bore meduim grade, 10 feet length, both ends flanged & drilled including cutting of grooves for submersible cable and fabrication etc complete all as specified and directed by Engr-in-charge. |
| 83 | S&F in replacement of digital auto timer clock suitable for borewells complete all as specified and directed by Engr-in-charge. |
| 84 | S&F in replacement of single phase preventorVSP-2 / VSP-1 complete all as specified and directed by Engr-in-Charge. Make:Minilac/ L &T/ Lagrand |
| 85 | S&F in replacement of MCB TP 32 to 63 Amp complete all as specified and directed by Engr-in-Charge. Make :Schneider/ Lagrand |
| 86 | Disconnecting electrically the switch change over of anytype as per site requirement and supply & fixing and connecting change over switch MCB TPN 4 pole 200 Amp 440 volts conforming to relevant IS including all connecting and jointing material complete all as specified and directed by Engr-in-Charge. |
| 87 | All as per item No 86 here-in-before but 125 Amps,440 volt complete all as specified and directed by Engr-in-Charge. |
| 88 | All as per item No 86 here-in-before but 100 Amps,440 volt complete all as specified and directed by Engr-in-Charge. |
| 89 | Disconnecting, electrically, isolating the existing unserviceable MCCB TP of any make and capacity and Supply, fixing, connecting, testing and commissioning MCCB 4 Pole, 440 volts fixed in existinig panel including necessary modification for new MCCB TP,250Amp capacity breaking capacity 36 kA conforminig to relevant IS including all joining and connecting material complete all as specified and directed by Engr-in-Charge. |
| 90 | All as per item No 89 here-in-before but 200 Amps,4 pole, breaking capacity 36 kA complete all as specified and directed by Engr-in-Charge. |
| 91 | All as per item No 89 here-in-before but 125 Amps, breaking capacity 16 kA complete all as specified and directed by Engr-in-Charge. |
| 92 | All as per item No 89 here-in-before but 100 Amps, breaking capacity 16 kA complete all as specified and directed by Engr-in-Charge. |
| 93 | All as per item No 89 here-in-before but 63 Amps, breaking capacity 16 KA complete all as specified and directed by Engr-in-Charge. |
| 94 | Taking up or down Electric motor and pump of 15 HP to 50 HP of any make or type after disconnecting from all the misscelenious items such as NRV, reducer, CI-Tee, Pipelines etc andelectric connection as all required at site including dimantling and taking out old rusted steel/iron channel/ foundation, vibration pad after taking all safety measures including all lifting work, welding work if any, cutting and supply and fixing vibration pad in six numbers and one steel/iron channel/motor foundation of size suitable for motor and pump of 15 HP to 50 HP fixing the motor and pump of above said capacity and fixing all connecting items including NRV, reducer, CI-Tee, Pipelines with all minor work such as cutting, welding, electric connection, nut, bolts, gland, flange etc of any size and make complete all as specified and directed by Engr-in-charge. |
| 95 | Supply, installation and testing in replacement of Electronic motor control panel for bore well upto 10 HP capacity submersible pump, 415 volts, 3 phase, 4 wire system with and including fully automatic star-delta starter, electronic automatic phase sequence corrector, input supply by MCCB 63 Amps, Digital Volt Meter/Amp Meter 4 inch square, selector switch with CTs, LED indicator lamps, Automatic motor protector , Phase sequence correctorcomplete including aluminium busbar of correct rating, out doortypeof size 800mm x 900mm x 350mm made out of MS sheet 3.15 mm thickpedastal type, grouting in PCC (1:4:8), type D-2 foundation complete all as specified and directed by Engr-in-Charge. |
| 96 | M&L for servicing of liquid chlorine dosing system, any make, any type/capacity complete including replacement of chlorine dosing pipe upto 2.5 mtr length for each plant including servicing of motor, washing of chlorine tank with descaling agent and re-commissioning testing of plant complete all as specified and directed. |
| 97 | Supply & fixing in replacement of phase sequence corrector 3 phase 415 volts with time delay relay with and including input supply, reverse phase protection against single phasing, voltage unbalancing, low voltage, high voltage etc with necessary copper connections complete all as specified and as directed. |
| 98 | S&F in replacement of lead acid battery 12 volts 180 AH of existing type & size suitable for Gen set 15 to 125 kva including initial charging and copper connector complete all as specified and as directed by Engr-in-Charge. |
| 99 | Material & Labour for painting to existing LT panels, indoor type installed at various pump houses with super enameled paint of approved colour on exposed surface including preparation of surfaces and applying primer coat complete all as specified and directed by Engineer-in-charge. |
| 100 | Description all as per item No 99 above but borewell panels (out door type) complete all as specified and directed by Engineer-in-charge. |
| 101 | Material & Labour for painting to existing centrifugal pump & motor set complete including base frame with supper enameled paint of approved colour on exposed surface including preparation of surfaces and applying primer coat upto 50HP capacity complete all as specified and directed by Engineer-in-charge. |
| 102 | Supply and fixing in replacement of unserviceable display board for showing details of pump houses and borewells/ SOPs/ layout of pipelines and installations as provided by Engineer -in-charge made out of PVC sheet of size 1.5mtr x 1mtr including GI angle frame and GI sheet cover to the frame and fixing of 2 nos LED tube light fittings 20 watts, connecting electrical supply to the frame including round stainless steel pole minimum 12 feet long of suitable dia for erection on ground with PCC complete including arrangement for dismantling the board for repair of LED Tubelights and fittings complete all as specified and as directed by Engineer-in-charge. |
| 103 | M&L for earthing complete with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip 32mm x 6mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) with fair finished internal surface of concrete chamber shall be given 15mm thick plaster in CM (1:4), funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified includingprovision of GI stripprotected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation andearth work & connecting the earthing to an earthing test pointcomplete all as specified & directed by Engr-in-Charge. |
| 104 | Yield test using V Notch for the existing bore well by continuously pumping for 8 hours to determine safe pumping yield complete all as specified and directed by Engineer-in-Charge. |
| 105 | Supply and fixing BI metallic over load relay, range 28-42 amp rating for automatic starters complete all as specified and as directed by Engineer-in-charge. |
| 106 | All as per item No 105 above but 20-32 Amps complete all as specified and directed by Engineer-in-charge. |
| 107 | All as per item No 105 above but 13-21 amp complete all as specified and directed by Engineer-in-charge. |
| 108 | All as per item No 105 above but 9-14 Amps complete all as specified and directed by Engineer-in-charge. |
| 109 | Supplying, laying and connecting in replacement of GI earth strip of size 32mm x 6mm by means of GI bolts, buts and washers complete all as specified and all as directed. |
| 110 | Supply and fixing for Amps meters 0 to 200 Amps, Digital type with selector switches, CTs etc complete all as specified and directed by Engineer-in-charge. |
| 111 | Supply and fixing for voltmeters 0 to 500 Volt, Digital type 415 volts with selector switches, CTs etc complete all as specified and directed by Engineer-in-charge. |
| 112 | Supply & fixing for power contactors 32 Amps, 415 volts AC operated 3 phase ML-1.5 or as per existing complete including taking down the existing complete all as specified and as directed. |
| 113 | All as per item No 112 above but 70 Amps, ML-4 complete all as specified and as directed. |
| 114 | All as per item No 112 above but 40 ML-3 Amps complete all as specified and as directed. |
| 115 | All as per item No 112 above but 110 Amps MNX type contractor complete all as specified and as directed. |
| 116 | All as per item No 112 above but 32-63 Amps MNX type contractor complete all as specified and as directed. |
| 117 | S&Fin replacement water proof joint for submersible cable suitable for size 4/6 sqmm 3.5/4 core complete all as specified and directed by Engineer-in-charge. |
| 118 | Supply, connecting, testing and commissioning submersible cable with copper conductor stranded of size 4 sqmm 3 core complete including dismantling the old unserviceable cable complete all as specified and directed by Engineer-in-charge. |
| 119 | Description all as per ser item no 118 here in before but 6 sqmm, 3 core complete all as specified and directed by Engineer-in-charge. |
| 120 | Supply and fixing PVC copper conductor cable of size 4.00 sqmm single core multistranded complete all as specified and as directed. |
| 121 | Supply and fixing PVC copper conductor cable of size 1.5 sqmm single core multistranded complete all as specified and as directed. |
| 122 | S&F in replacement clamps fabricated out of 100mmx6mm MS flat for 80mm bore column pipe alongwith bolts, nuts and washers complete all as specified and directed by Engineer-in-charge. |
| 123 | Supply & Fixing type coupling for upto 50 HP complete all as specified and directed by Engineer-in-charge. |
| 124 | S & F in replacement of gun metal sleeves for 30 HP to 50 HP complete all as specified and as directed. |
| 125 | S&F in replacement strainer of dozing pump complete all as specified and as directed. |
| 126 | S&F in replacement suction and delivery tubePVC 12mm dia suitable for dozing pump complete all as specified and as directed. |
| 127 | S&F wire netting of galvanised steel wire 0.71mm dia fixed with tinned tacks of wire staples of mesh 25mm complete all as specified and as directed. |
| 128 | M&L for chemical and bacteriological analysis and potability of water obtained from borewells at all pump houses from MCD approved/ NABL approved micro engineering and testing lab and submitting the report in duplicate complete all as specified and as directed by Engineer-in-charge. Note:- The report shall be carried out quarterly and shall be submitted to GE for verification and record. |
| 129 | S&F chlorine test kit H13829F that uses DPD method to measure free chlorine. It should contain pre-made reagents(sulphuric acid, sodium hydroxide) for ease of use all reagents marked with expiry date and lot number for traceability and colour comparision tube for sample determination complete all as specified and as directed. |
| 130 | Supply and fixing in replacement of old unserviceable display board for showing details/ Schematic diagram of borewells water supply installation duly printed in English alphabetas provided by Engineer -in-charge made out of PVC sheet of size 1.5 mtrX1 mtr including GI angle frame and GI sheet cover to the frame and fixing of 2 nos LED tube light fittings 20 watts 2 feet, connecting electrical supply to the glow sign boardd including grouting with PCC (1:2:4) in founddation fixed at 1.2 mtr above ground level complete all as specified and as directed by Engineer-in-charge. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy