| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(a) Group C |
| 2 | Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 3 | (a) 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire |
| 4 | (b) 4 x 2.5 sq. mm + 2 x 2.5 sq. mm earth wire |
| 5 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.(a) 12 Module |
| 6 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 7 | (a) 5/6 A switch |
| 8 | (b) 3 pin 5/6 A socket outlet |
| 9 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 10 | Supplying and fixing 12 module GI modular surface box on wall surface along with suitable modular base & cover plate including fixing 4 Nos. 5/6 A modular switches and 4 Nos. 5/6 A modular socket outlets and including connections etc. as required. |
| 11 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor notless than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 12 | Supplying and Installation of 300 mm heavy duty exhaust fan(minimum 1400 RPM) in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 13 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(a) 12 way double door |
| 14 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)(a) 4 way (4 + 12), Double door |
| 15 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) 100 A |
| 16 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 17 | (a) Single pole |
| 18 | (b) Single pole and neutral |
| 19 | (c) Triple pole |
| 20 | (d) Triple pole and Neutral |
| 21 | Supplying, Istallation, Testing and Commissioning of 3 Nos of 32 A rotary phase selector switches (4 modes) along with LED indicator for each switch inside suitable sheet steel enclosure with proper interconnections and fixing the enclosure on wall surface as required including providing connections to incoming and outgoing cables (excluding glands) as required at the site of work. |
| 22 | Supplying, installation, testing and commissioning of 3 Nos of 200 A, 415 V fuse carriers and neutral bus bar with fixing the carriers in suitable size 14 SWGCRCA sheet steel enclosure on wall surface by replacing damaged carriers, making proper connections etc as required or as directed by Engineer in Charge. |
| 23 | Supplying and fixing 14 SWG CRCA sheet steel distribution box of following sizes on wall/ pole as cable junction boxes, including supplying and fixing 4 Nos bus bars of 200A capacity, properly connecting incoming and outgoing cables with suitable arrangements as required or as directed by Engineer in Charge. (excluding cable glands) (a)600x450x300 mm |
| 24 | Supplying, installation, testing and commissioning of 1200 mm 20W LED T8 tubes with extruded Al body, PC diffuser and inbuilt driver with efficacy of 100 lumens/W with suitable box type batten on wall/ ceiling/ truss with suitable fitting arrangements to terminate the ceiling rose/metal conduit wiring with check nut to the fittings etc as required. (non compact type) ( ISI certified ) |
| 25 | Supplying, Installation,Testing and commissiong of following rating LED floodlight made up of pressure die cast aluminum housing with toughened glass and high power LEDs as light source with IP66 protection,LEDs with lumen efficacy of >140 lm/W, System efficacy of > 110 lm/W,colour temp 5700 K,THD( %) < 10 with suitable clamps and nut bolts on wall/ pole with proper angle iron setup at site of work including connectionswith3 x 1.5 sq mm copper conductor cable etc., as required. (a) 60W |
| 26 | Supplying of PVC insulated, PVC sheathed / XLPE aluminium conductor armoured undergroundpower cable of 1.1 KV gradeconforming to IS 1554 part-I/7098(part-I) 1998 with up to date amendments of the following sizes. |
| 27 | (a) 3 x 10 sq mm |
| 28 | (b) 3 x 16 sq mm |
| 29 | (c) 3 1/2 x 35 sq mm |
| 30 | (d) 4 x 25 sqmm |
| 31 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required(a) 100 mm dia |
| 32 | Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole/wall for protection of under ground cable as required. |
| 33 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.(a) up to 35 sq mm |
| 34 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.(a) Upto 35 sq. mm |
| 35 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.(a)up to 35 sq mm |
| 36 | Laying and fixing of one number ofPVC insulated and PVC sheathed/ XLPE armoured U Gpower cable of 1.1 KV grade of following sizes on wall surface/truss(or in recess of wall/floor by cutting the surface and making good the same) as required.(a) Up to 35 sq.mm (clamped with 1mm thick saddle) |
| 37 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 38 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required |
| 39 | (a)3 x 10 sq mm(22 mm) |
| 40 | (b) 3 x 16 sqmm (25 mm) |
| 41 | (c) 3.5 x 35 sqmm (32 mm) |
| 42 | (d) 4 x 25 sq mm (28 mm) |
| 43 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.(a) 3.5 x 35 sqmm |
| 44 | Supplying and erection of SMC box of following sizes on wall/ pole as cable junction boxes along with adequate bus bar setup including properly connectingincoming and outgoing cables with suitable arrangements as required (excluding cable glands)(a) 350x250x130 mm in side |
| 45 | Providing and making steel pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/ pipe not to be deducted) |
| 46 | Providing and fixing M.S. Fan clamp of standard shape and size in existing R.C.C. slab/truss, including drilling and painting with accessories as required. |
| 47 | Earthing with 60 mm outer dia, 2 mtr length GI earthing electrode,completely filled with conductive crystaline compound, fitted with minimum of 40x 6x2000mm GI strip including 50 kg of eco friendly maintenance free earthing compound to enhance soil conductivity and providing masonry enclosure with cover plate having locking arrangement etc. at the site of work as required. |
| 48 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 49 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 50 | Dismantling of aluminium wire from the existing conduit, main board, sub-main boards, switch boards and shifting to depot stores etc., as required. |
| 51 | Credit items to be taken |
| 52 | (a) Dismantled aluminium wire |
| 53 | (b) Dismantled DBs , switch gear and other accessories |
| 54 | (c) Dismantled ceiling fans |