Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 30-08-2024 | Due Date Extended for tenders closing on 09-08-2024 | Admin Corrigendum Date Extend | 06-09-2024 |
| 2 | 25-07-2024 | Datecorrigendum2 | Date | 09-08-2024 |
| 3 | 15-07-2024 | Datecorrigendum1 | Date | 03-08-2024 |
| 4 | 08-07-2024 | Datecorrigendum | Date | 26-07-2024 |
| Sl. No. | Item Description |
| 1 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth forlaying of UG cable/pipe in soft /loose soil complete all as specified and as directed. |
| 2 | Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25cm thick complete all as specified and as directed. |
| 3 | Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed. |
| 4 | Supply and laying 50 mm outside dia double corrugated pipe (DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. |
| 5 | Materials and labour for GI tubing of 50 mm bore light grade with all fitting fixed to wall/ceiling/pole or in trench formed by road/PCC cutting/boring/ laid on floor as cable protection all as specifed and directed. |
| 6 | Supply and laying in trenches/wall LT UG XLPE insulated ,armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 70 sq mm x 3.5 coreincluding taking down old unserviceable cable and making necessery connections all as specified and as directed. |
| 7 | All as item no 6 but of size of cable 50 sqmm 3.5 core |
| 8 | All as item no 6 but of size of cable 35sqmm 3.5 core |
| 9 | All as item no 6 but of size of cable 25 sqmm 4 core |
| 10 | All as item no 6 but of size of cable 16 sqmm 4 core |
| 11 | All as item no 6 but of size of cable 16 sqmm 2 core |
| 12 | All as item no 6 but of size of cable 10 sqmm 4 core |
| 13 | Supply and fixing cable jointing kit for 1.1 KV grade for straight through joint complete with jointing material heat shrink type and accessories suitable forXLPE armoured aluminium conductor cable of size 10 to 50 Sqmm 3.5/4 core indoor/outdoor type including taking out & relaying damaged cable after repair complete all as specified and as directed.(Excavation and connected items will nbe measured and paid separately.) |
| 14 | All same as item No. 13 above butfor cable of size 70-185 sqmm 4 core. |
| 15 | Materials and labour for water proof, 3core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings with MCB SP in junction box, complete all as specified and directed. |
| 16 | Supply and fixing as in repairsMCCB four pole , 415 Volt, 100 Amps,25 KA , fixed thermal &magnetic setting complete all as specified and directed . |
| 17 | Dismantlingdefective sewage non clog type sewage pump set of 10/7.5HP capacity testing on site and cutting unsv copper winding in front of MES Rep opening suction, delivery pipe line connections,coupling nut bolts and taking out the pump set and transportingto the contractors workshop for repair, machine workand transporting to the site, refixing, assembling coupling with motor,lowering downand connecting suction and delivery line and testing on full load for 04 hours including providing gland packing and making the pump leak proof incl any other minor work as required at site and directed by Engineer-in-Charge.Note:-i) Spare parts replaced shall be measured and paid separately as supply only under respective item of schedule ii)Transportation charges for the motor towksp & back are deemed to be included in rates quoted, no extra payment will be made on this account.iii)Pump set issued for repair must be returned & installed duly repaired within seven days otherwise Rs 500 per day per pump will deducted from the bill as penalty.iv)Minor items like nut/bolts, bearing grease, packing gaskets of required size to be taken in consideration while quoting the rates. No extra payment will be made on this account. |
| 18 | Supply only impeller set for one submersible sewage pump set up to 10 HP. |
| 19 | Supply only mechanical seal set for one submersible sewage pump set up to 10 HP |
| 20 | Supply only oil seal for one submersible sewage pump set up to 10 HP |
| 21 | Supply only rubber gasket sealing for one submersible sewage pump set up to 10 HP. |
| 22 | M & L for rewindingburnt coilsof Induction Motor stator of Capacity10 HP with super enamelled copper winding wire as per existing size and guage to achieve therequired /specifiedRPM including taking out old unserviceable winding ,cleaning/ repairing damaged slots , completeall as specified and as directed. Note:- i) Spare parts replaced shall be measured and paid separately as supply only under respective item of schedule ii)Transportation charges towksp & back are deemed to be included in rates quoted, no extra payment will be made on this account.ii) Motor issued for rewinding must be returned & installed duly repaired within seven days.(iv) Contractor will arrange testing of motor on full load for contineous eight hours. Contractor or his rep will be present on the site during the testing period.v)Minor items like connection plate, copper lugs for cable,connection plate cover to be considered while quoting the rates. No extra payment will be made on this account. |
| 23 | All same as item No. 22 above but of Capacity 7.5 HP |
| 24 | All same as item No. 22 above but of Capacity 5 HP |
| 25 | Supply and fixing flat submersiblemulti stranded copper conductor cable of size 6 sqmm 3 core complete all as specified and as directed. |
| 26 | Supply and fixing in replacement including lowering of Steel wire rope, PVC insulated of size 10 mm dia of suitable size/ length as directed with clamps, nuts & boltsand washers etc for holdingcolumn pipes / GI pipes of submersible pump set complete all as directed by Engr-in-Charge. |
| 27 | Labour only for inspection of fault in panel,starter, motors and replacement of unsv electronic parts including taking down and testing all as directed by Engr-in -Charge.(Note: 1.spare parts of panel, starter will be paid separately under respective items2. All T& P and TPT used is deemed to be included in item rate) |
| 28 | Supply only Power contactor suitable for 5HP of existing make and capacity |
| 29 | Supply onlyPower contactor suitable for 7.5/10 HP of existing make and capacity |
| 30 | Supply onlySingle phase preventor suitable for5 HP of existing make and capacity |
| 31 | Supply onlySingle phase preventorsuitable for 7.5/10 HP of existing make and capacity |
| 32 | Supply onlyDigital panel volt Meter 3 phaseFlush Mounting 96x96mm, Accuracy Class-I, input voltage measurement range 17-520V AC (P-P) |
| 33 | Supply onlyDigital panel ammeter, 3 phase 5A,Flush Mounting 96x96mm, Accuracy Class-I, CT/PT Site programmable |
| 34 | Supply onlyIndicator lamp 3 phase |
| 35 | Supply onlyElectronic Timer160-500V ,for 3-30sec |
| 36 | Supply onlyOver load relay suitable for5HP of existing make and capacity |
| 37 | Supply onlyOver load relay suitable for7.5/10 HP of existing make and capacity |
| 38 | Supply onlyON OFF push button |
| 39 | Supply only dry run protection relay |
| 40 | Supply and fixing 40 mm GI pipe medium grade for UG cable protection with all fitting fixed topole or laid in trenches or laid in floor/rood all as directed. |
| 41 | Taking down existing unserviceable/Faulty LT UG cable 1100V of any size from existing location and relaying the same after necessary repair work all as specified and as directed(Note: Items if required for repair and excavation works will be measured and paid separately under relevant items) |
| 42 | Relaying of old recovered cable cover or brick of any size in trenches all as directed by Engr-in-Charge |
| 43 | Supply and fixing cable junction box with terminals having dressed with four colour Tap, having protection\"weather proof\" for outside installation with metric knockout entry for cable of size 25 sqmm 4 core and size 295x195x95mm with terminals and provision of one MCB SP 6A complete with all pole brackets and fixing arrangements all as specified and as directed. |
| 44 | Supply , installation , testing and commissioning of chlorine feed high pressure dozing pump set with accessories having minimum flow rate of 25 LPH, minimum discharge pressure 15 Kgs/cm2 and liquid chlorine dozing system consisting of atleast 100 ltr FRP tank with accessories and fitted with automatic mixer (non manual) including making connection in main line and fixing arrangement including testing for maintaining 2-3 PPM including taking out u/s dozing pump and remove from site complete all as specified and directed.Note: (i) Unsv dozing pump shall be deposited in MES store yard of AGE E/M Sevoke Road. |
| 45 | Materials and labour for blocking of incoming sewage water in sump,dewatering desliting / taking out accumulated sludge, Silt, Mudetc. from sewage collection sump and connected channels including scrapping down and cleaning internal surface of walls, Floors, Roofs, Mechanical Parts and cleaning blockage of wash out channels, pipes Drainage system etc. and removing the same to a distance not exc. 50 Metre and reopening of blockage of sump complete all as specified and as directed. |
| 46 | Materials and labour for cleaning of Equalizing tank /grit chamber/ oil grease chamber/stilling chamber of Sewage Water in thetank and Removing of settle down Sewage sludge cum mud/De-Silting etcall as required at site anddirected by the Engineer-in-Chargefor Sewage tank of size as per drawing attached).Note: The rate quoated by the tenderer is deemed to be included in the unit rate of the following :- (a) Diesel/ electric Driven Pump Set of appropriate capacitywith operatorsincluding necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes. (b) Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same to the location where approved (c ) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineer-in-Charge. |
| 47 | Materials and labour for dewatering, desliting / Taking out accumulated sludge, Silt, Mudetc. from FAB Reactor,tube settler tank, TWTand connected channels including scrapping down and cleaning internal surface of walls, Floors, Roofs, Mechanical Parts and cleaning blockage of wash out channels, pipes Drainage system etc. and removing the same to a distance not exc. 50 Metre complete all as specified and as directed. |
| 48 | Materials and labour for blocking of incoming sewage water in sump,dewatering desliting / taking out accumulated sludge, Silt, Mudetc. from sewage collection sump and connected channels including scrapping down and cleaning internal surface of walls, Floors, Roofs, Mechanical Parts and cleaning blockage of wash out channels, pipes Drainage system etc. and removing the same to a distance not exc. 50 Metre and reopening of blockage of sump complete all as specified and as directed. |
| 49 | Removal of MBBR media from MBBR tank, Tube settler media from tube settler tank, Filter media for DMF and ACF filters and reloading the same after cleaning and new media reloading complete all as specified and directed by Engineer-in- Charge. |
| 50 | Supply and pouring Bio media made of plastic and corrugated shape having surface area 260 sqm/cum in MBBR as directed by Engr-in-charge. Make: MM Aqua, Bharat, SIMA |
| 51 | Material for replacement of quartz silica sand 32-64 grade complete all as specified and directed by Engr-in-charge. |
| 52 | Material for replacement of quartz silica sand 16-32 grade complete all as specified and directed by Engr-in-charge. |
| 53 | Material for replacement of quartz silica sand 8-16 grade complete all as specified and directed by Engr-in-charge. |
| 54 | Material for replacement of quartz silica sand 4-8 grade complete all as specified and directed by Engr-in-charge. |
| 55 | Material for replacement of activated carbon complete all as specified and directed by Engr-in-charge. |
| 56 | Materials and labour for painting with two coat of black bituminous paint internal surface of ACF /DMF complete all as specified and as directed |
| 57 | Materials and labour for painting with two coat of alumunium paint to external surface of ACF/DMF incl one coat of red oxide after scapping old paint complete all as specified and as directed |
| 58 | Materials and labour for two coats of synthetic enamel painting to exposed CI/GI/MS pipe lines of header/suction/delivery of pumps any type/make/size including sluice valves, fittings and non return valves at water supply installations as per specified colour code after cleaning and scraping out old paint including writing/marking complete all as specified and directed by Engineer-in-charge |
| 59 | Supply and fixing as in repairsDry run protection relaywith detection of single phase preventor,VI meter(current based), 3 Phase Motor Starter or as per existing sizecomplete all as specified and as directed |
| 60 | Supply, laying , jointing, welding & testing MS pipe 100 mm bore ( Heavy duty Class \"c\") including fitting as required of following sizes laid in treches or laying oe floor for connecting to various STP accessories and to connect outgoing water main including taking down the unserviceable pipe all as directed by Engr-in-charge. Note:- MS flange and flange joint complete with jointing material shall deemed to be included in the unit rate of this item |
| 61 | All as per item No 60 abovebut for 80mm bore |
| 62 | All as per item No 60 abovebut for 50mm bore |
| 63 | Material and labour for CI butterfly valve 100 mm bore of following sizes, stainless steel disc as per IS 13095 class PN-1.0 complete with nuts, bolts, washer and rubber gasket including taking out old unserviceable butterfly valve complete all as specified and directed by Engr-in-charge. |
| 64 | All as per item No 63 abovebut for 80mm bore |
| 65 | All as per item No 63 abovebut for 50mm bore |
| 66 | Servicing of air compressor coupled with blower motor 30 HP capacity Installed at Sewage treatment plant including necessary arrangement to transporting to workshop fro re-grinding of shaft, oiling ,greasing etc and necessary replacement of wornout bolts ,nuts ,washers, silencer, belt drivers, pressure guage, air-filter, bearings,ringsetc .Re-assembling the compressure with blower motor , commissioning and testing to the entire satisfaction of Engineer - in - charge . |
| 67 | Supply only compressure oil all as specified and directed. |
| 68 | Materials and labour for replacement of MS Shaft of the electric motor upto 30 HP 440 Volts in repairs complete all as directed. |
| 69 | Materials and labour for dismantling of 30 HP motor,transporting to workshop and rewinding with super enamelled wire of existing guage size, varnishing, heating and refixing motor on its location including testing for 06 hrs continuous run complete all as specified and as directed |
| 70 | Servicingof 3 Phase 415 Volts 1440 RPMCentrifuge Motor coupled with NC HorizontalMulti staging Pumping Set as following:(a) Taking out Motor from its Position by decoupling from Pump and disconnecting all cable connections, Heating & varnishingto stator with super quality varnish Reassembeling the motor, greasing the bearing with bearing grease ,Reinstall the Motor at its existing Position , couple with the Pump connecting all cable connections and testing on completion complete all as specified by Engineer-in- Charge.b). Taking out Pump from its Position by decoupling from Motor and disconnecting , degreasing bearingand display all the parts without damaging any portion for inspection of Engineer-in- Charge to ascertain the serviceability of existing parts, Replacement of Gasket set and gland packing rope,greasing the bearing with bearing grease ,Reassembeling the Pump complete with all existingserviceable parts, Reinstall the Pump at its existing Position , couple with the Motor and connecting all suction delivery waterconnections and testing on completion complete all as specified by Engineer-in- Charge. |
| 71 | Surface dressing in hard/dense soil,not exceeding 15cm deep for cleaning the area by cutting the unwanted bushes/vegetation growth in and around the area of installation/around the valve pit chamber/along the pipeline routes if reqd etc all as specified and directed by Engr-in-charge. |
| 72 | Materials and labour for scraping old paint of Electric Panel and Painting with two coats of syntheticenameal paint over a coat of red oxide primerincluding disconnecting electric connection and re-wiring without any damage of existing parts as directed by Engnr-in-Charge complete as all specified and as directed. |
| 73 | Materials and labour for plain cement concrete 1:3:6 type C-2 (40mm graded aggregate) as in foundation and bed concrete complete all as specified and as directed |
| 74 | Supply only chemical for drinking water treatment , calcium based granular high strength disinfectant chlorinating chemical having65 %to 70 % chlorine content in granular form in a 45kg drum.Brand/Make shall be from any manufacturer aproved by E-in-C\"s branch on date of supply. |
| 75 | Supply and mixing of Dewatering Poly Electrolite 100 % Purity. |
| 76 | Testing of following parameters in discharge water sample obtained from sewage treatment plant through authorised govt. agency :(i) pH (ii) TSS(iii) BOD (iv) COD(v) Residual Chlorine(vi) Coliform |
| 77 | Supply, installation, testing & commissioningof approved factory made outdoor type LT feeder pillar box made out of stainless steel grade-304, 2.00mm thick cubical enclosure comparmentalized suitable for 3 phase 4 wire 415V,50 Hz, IP-54 of appropriate size as approved by Engr-in-charge totally enclosed weather, dust vermin proofmade of angle iron frame50mm X50mmX6mm with cable entry and exit through bottomwith double compression copper cable glands and gaskets, front & back side operated double door with properhinge and locking arrangement with Al bus bar fixed on porcelain insulator and shall be complete including internal wiring using with suitable size of copper conductorcablesand aluminium stripsfor incoming and outgoingconnections of all switches/MCB\"s,/ MCCB\",Bus bar cable alley .Bus bar shall be insulated with colour code/sleeves/tapes including necessary PCC (1:3:6)type C2 for foundation /Platformall as specified and directed.LT panel boardshall be completed in all respects and includingthe following accessories:- INCOMING : (i) 4 pole MCCB having breaking capacity 16 KA of rating63 Amps.- 01 No. OUTGOINGS : (i) MCCB, 4 pole, 10 KA of rating 40 Amps.- 02 No (ii) MCB, TPN, \"C\" curve, 10 KA of 32 Amps.- 02 Nos (iii) Fully automatic submersible pump controller star delta starter of capacity 7.5 HP with feature of protection from overload single phasing, phase reversal, phase imbalance, auto restart with indication of On/Off, voltage and amps -02Nos(v) Motor protection relay-02 Nos. (vi) Single phase preventer relay-02 Nos.INSTRUMENTATION SYSTEM :-(i) Digital Voltmeter 96 mm x 96 mm including selectror switch suitable to read 0 volt to 500 volts (AC 50 Hz), Class-1.0- 01 No. (ii) Digital Ammeter 96 mm x 96 mm with suitable CT - 02 set (iii) LED Pilot Lamp (for Incomers) suitable for 230/240 Volts AC supply complete with integral circuit & cluster LED of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No. (iv) Danger Notice Plate duly written in Signal Red colour on Aluminium plateof size not less than 150mm x 100mm - 01 No. (Note : (i) Cost of PCC 1:3:6 for foundatin and platform is included in the quoted rate. (ii) Incoming & outgoing MCCB shall be connected wih busbar. ) |
| 78 | Supply & install test point terminal made out of GIstrips 32 mm x 6 mmwith GINuts & bolts mounted on busbar insulators (2Nos) fixed on wallas directed. |
| 79 | Materials and labour for air termination, single pointed aluminium rod 12 mm dia and 300 mm longall as specified and as directed. |
| 80 | Materials and labour aluminium strip 25x3 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground including taking down unsv complete all as specified and as directed. |
| 81 | Materials and labour for porcelain insulator suitable for fixing earthing strip to the wall / floor etc all as specified and as directed |
| 82 | Supply andfixing galvanised iron strip 32 x 6 mm buried in ground forinterconnection of earthing including taking down unsv complete all as specified and as directed. |
| 83 | Materials and labour for earthing complete with galvanized steel pipe electrode 40mm bore, medium grade, 3.5 meters length, buried directly and preferably vertically in ground with top edge not less than 1.25 meters below ground level connected with earthing lead galvanized iron strip of size 25x4 mm connected to galvanized earth pipe by means of bolts, nuts, checknuts and washer of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 6mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanized steel tube for watering with one end fix with cast iron funnel and wire-mesh, with protection pipe of 32 mm dia light grade galvanized steel tubing upto 7.5 meters length for drawing earthlead including common salt, charcol , bentonite in alternate layers etc all in around of earthing pipe of 600mm dia, complete all as shown in EP number 2 of SSR Part-1 including testing on completion and including taking down old U/S earthing & testing complete all as specified and as directed. |
| 84 | Supply and installation of advanced encapsulated compound based CPRI tested maintenance free Pipe pin pipe technology upgraded (zinc and alloy coated) zinc coated (80 to 100) microns with Pure zinc 99.9%and alloy coating200 to 250 microns Earthing system confirmingIS 3043. The outer and inner pipe should be76.2 mm and 41.9 mmdia or 48.3 mmand 26.4mm 3 meters length zinc coated with additional special pipes being filled up with compact fill crystalline conductive compound the compact film mixture which is machine pressed in the pipe should not disintegrate or collapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity the job includes dealing the pits and refilling the same by Baron Electrode backfill compound. The BFC should be eco friendly it should not contain environmentally hazardous material metal having ROHS certification from NABL accredited lab. The earthpit should be providedwith FRP or EPCC earthpit coverfor protection and safeguard of terminals in areas where soil condition is bad. Good earth that is black cotton or moisturenormal soilis to be arranged to fill the excavated pits by mixing the arranged soil with BFC 2-4 bags electrode BFC for installation of earth electrode. Resistance of Earthing should be less than 1 ohm. Make: Ashlok Model : Aseel 39 or equivalent model in make Indelec/Erico/Macmate. |
| 85 | Materials and labour for taking out cable loop of LT feeder panel and seperating old insulation and fixing cable end jointing kit for the size of the cableupto 120 Sqmm 3.5 core sizecomplete all as specified and as directed by engineer-in-charge. (Note: Excavation shall be paid extra under relevant items. |
| 86 | Supply and fixing in repair stainless steel 2 way Fire Brigade Inlet connection ISI marked with inbuilt Check Valve including taking down and removed from site complete all as specified and as directed. |
| 87 | Supply and fixingin repair stainless steel 63 mm bore Heavy Duty Single Headed Fire Hydrant Landing valve As per IS:5290 type \"A\" ISI marked with ABS Blank capincluding taking down unserviceablve valve and removing from site complete all as specified and as directed. |
| 88 | Supply and fixing in repair Hose reinforced rubber lined fire Pipe ofSize 63 mm bore (15 Mtr Length ) WithBoth Side SS coupling ISI marked Male & Female connection type including taking down complete all as specified and as directed. |
| 89 | Supply and fixingin repair Branch Pipe with SS Nozzle as per IS 903 ISI marked including taking and removing from site down complete all as specified and as directed. |
| 90 | Supply and fixingin repair of Hosebox made of 18 gange MS sheet 800 mm x 600mm x 250 mm with double door with 4 mm thick glasses and door fram made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete including taking out old unservicebale Hose box and removing from site compelte all on specified and directed. |
| 91 | Supply and fixing in repairHose reel Drum ( Wall Mounted) swingingtype as per IS : 884 includingHose pipe Length 30 Mtr Long of Size:- 20 mm bore thermo plastic hose as per IS 12585, ISI markedwith PVC ¾ “ Shutoff Nozzle (Hydraulically Crimped) including taking down and removing from site complete all as specified and as directed. |
| 92 | Supply and fixingin repair PVC Shut off Nozzle Size 20 mmbore ISI marked including taking down complete all as specified and as directed and removing from site. |
| 93 | Supply and fixing in repair Hose Clamp including taking down and removing from site complete all as specified and as directed. |
| 94 | Supply and fixing in repair 100mm Dual Plate Check Valve :- Cast Iron Body , D.I. Doors ,Nitrile /EPDM Seat ,Stainless Steel Shaft and springs P.N. 1.6 including taking down unserviceable and removing from site complete all as specified and as directed. |
| 95 | Supply & Refilling of Carbon di Oxide Fire Extinguisher 4.5 Kg each complete all as specified and as directed. |
| 96 | Supply & Refilling of ABC Powder Fire Extinguisher 6 Kg Each complete all as specified and as directed. |
| 97 | Supply & Refilling of D-Fire Mechanical Foam Extinguisher 9 Ltr capacity each complete all as specified and as directed. |
| 98 | Supply & Refilling of Watermist baseFire Extinguisher 9 Ltr capacity each complete all as specified and as directed. |
| 99 | Supply only Fire Extinguisher Hose Pipe ABC Type |
| 100 | Supply only Fire Extinguisher Hose Pipe CO2 Type |
| 101 | Supply only valve kit for Fire Extinguisher ABC Type |
| 102 | Supply only Fire Extinguisher valve for foam type |
| 103 | Supply only Fire Extinguisher valve forWatertype |
| 104 | Supply only Pressure Meter |
| 105 | Supply only Hanging Clip ( Hooke ) for Fire Extinguisher |
| 106 | Supply only Carbon di Oxide Fire Extinguisher 4.5 Kg each |
| 107 | Supply only ABC Powder Fire Extinguisher 6 Kg Each |
| 108 | Supply only D-Fire Mechanical Foam Extinguisher 9 Ltr capacity each |
| 109 | Supply only Watermist baseFire Extinguisher 9 Ltr capacity each |
| 110 | Labour only for Control Panel Fault Detection & Rectification by changing Necessary defective Components along with necessary copper wire, Lugs, Terminal etc. including testing complete all as specified and as directed.Note: Spare parts will be measured and paid separately under approprite item |
| 111 | Supply only 3 Pole 32 A Power Contactor |
| 112 | Supply only Thermal Overload Relay ,Relay Range 14-23 A |
| 113 | Supply only Setof 3 Phase Indicating Lamps (Red Yellow & Blue ) |
| 114 | Supply only Push Button Assembly with auxiliary contact BlockStart & Stop |
| 115 | Supply only 63 Amp TPN MCB10 KA |
| 116 | Supply only 1 Pole 2 Way Rotary Cum Switch for Auto & Manual selection |
| 117 | Supply only Single Phase Preventer |
| 118 | Supply only Danfoss Make KP35 Pressure Switch |
| 119 | Supply only Ball Valve 15 mm |
| 120 | PVC Insulated & PVC Shethed Multi core bright Annealed bare Copper Conductor flexible Round Cables Size 1 Sq mm 2 core FRLSH |
| 121 | Servicing of motor pump set of capacity 5/7.5 HP by disassembling, (i) Motor Front over and back cover part by part dismantling, Internal Coil Heat Varnish, Insulation Testing & refixing. (ii) Pump Part by part Dismantling, ThroughServicing, replacement ofbearing & Gland Packing /Mechanical seal,re assembly with proper alignment complete all as specified and as directed. |
| 122 | Materials and labour for re-winding of motor with superior quality copper winding wire of existing size including varnishing and drying cable jointing and repair replacement of worn at parts of motor/pump reassembling , re-installing at site and testing the same complete all as specified and as directed. |
| 123 | Materials and labour for painting of motor pump set complete all as specified and as directed |
| 124 | Materials and labour for painting of fire fighting water MS pipeline by red colour synthetic enamelled paint by suitable safety arrangement upto height of 20 mtrs heightcomplete all as specified and as directed. |
| 125 | Materials and labour for repairing of fire fighting alarm control panel & rectification by changing necessary defective components alongwith necessary copper wire , PCB repairing work including testing on completioncomplete all as specified and as directed. |
| 126 | Supply and fixing in replacement fire alarm metalic body ISI marked complete all as specified and directed. |
| 127 | Supply and fixing manual call point ISI marked PVC/ABS body wall mounting type including grouting of MCP on wall using 1:3:6 plastercomplete all as specified and directed. |
| 128 | Supply, laying, jointing & testing MS tubing heavy grade 100mm tubing medium grade with all fittings such as bends, elbow, tee, socket, reducers, unions etc as required at site laid in trenches or fixing complete with clips, wall hooks etc. complete all as specified and directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail