Tender For Development Of Tourism Amenities At Sohagi Barwa Wildlife Sanctuary, Maharajganj
Tender Value
3.70 Crore
Estimated cost
Bid Submission
04 Jul 2024
0 days left
EMD
7.40 Lakhs
Bank guarantee accepted
Document Fee
17700
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
mahrajganj → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Development Of Tourism Amenities At Sohagi Barwa Wildlife Sanctuary, Maharajganj
BOQ
| Sl. No. | Item Description |
| 1 | ADMIN BLOCK,CAFETERIA & INTERPRETATION AREA (Civil) |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. |
| 3 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-lll) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 5 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.. |
| 6 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) |
| 7 | Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration |
| 8 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2(1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 9 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level |
| 10 | Concrete of M-25 grade with minimum cement content of 330 kg /cum |
| 11 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V level |
| 12 | Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 13 | M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 14 | Providing and laying damp-proof course 25 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). |
| 15 | Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 16 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 17 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 18 | Providing machine made Wire Cut Bricks where edges are sharp and borders are straight and Size of8.5\"x 4\"x3\"having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%. Thickness of 230mm wall |
| 19 | Providing and fixing exposed brick flooring with modular common burnt clay bricks, machine made bricks: Indian chamfered and classic belgian rough bricks where edges are sharp and borders are straight and Size of200X100X40 for belgian rough and 230X110X25 for Indian chamfered having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%on a bed of 12 mm cement mortar, to be laid in pattern as per drawing approved from Architect in charge including filling the joints with same mortar (make Prayag Clay Products or equivalent) |
| 20 | Supply and Laying a water soluble penetrative solution for waterproofing of masonry building material & Nano technology based as it provides molecular level hydrophobicity to inorganic substrate .The product is based on organosilicon chemistry, hence reacts with the inorganic substrate surface, seals the surface uto a depth of 2-3 mm and provides long service life where Nano size allows penetration deep into substrate that provides 20+ years water repellency.(Zycosil/Pratt & Lamber or Equivalent) including cost of all materials, labour tools and plants etc. required for proper completion of the work. |
| 21 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. (TMT Fe-500) |
| 22 | 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 coarse sand) |
| 23 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand |
| 24 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarsesand. |
| 25 | 12mm thick plaster in 1:3 on ceiling and soffitsof stairs upto floor two level. |
| 26 | Forming groove of uniform size from 12x12 mm and upto 25x15 mm in the top layer of washed stone grit plastered surface as per approved pattern, including providing and fixing aluminum channels of appropriate size and thickness (not less than 2 mm), nailed to the under layer with rust proof screws and nails and finishing the groove complete as per specifications and direction of the Engineer-in-Charge |
| 27 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to 1S:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily,Glazed Vitrified tiles Matt/Antiskid finish of size 600 x 600 mm |
| 28 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 29 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade ofthe slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 30 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 31 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm. Granite stone slab of all colour and texture |
| 32 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor). |
| 33 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any Size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 34 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 35 | (a) Single leaf |
| 36 | (b) Double leaf |
| 37 | Both side laminated |
| 38 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin- charge.Extruded section profile size 48x40 mm |
| 39 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash andmullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. |
| 40 | Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speeds Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. |
| 41 | Using R4 series with frame (115 mm & above) x (45 mm & above) & both glazed and fly screen sash (44 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coatedhandle on every glazed panel along with multipoint locking system. (Height above 1.8m) |
| 42 | Wall Painting with plastic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats (For Internal wall surface) |
| 43 | Wall Painting with plastic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats (For Internal ceiling surface) |
| 44 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 45 | Natural Mud plaster+ paint Aggregate made up of Lime, Clay & Additives in given proportion to get the desired Texture.Shade, Texture and number of coatsas per architects approval to get the desired finished |
| 46 | Cost of Artistic Mural & painting as per Design received from Architect Incharge. |
| 47 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to |
| 48 | IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick |
| 49 | jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 50 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 51 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . |
| 52 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete |
| 53 | (a) 300 mm x 10mm |
| 54 | (b) 200 x 10mm |
| 55 | Providing and fixing stainless steel handles with screws etc. complete (a) 150 mm |
| 56 | Float glass panes 4 mm thick glass pane (weight not less than 10 kg/sqm). |
| 57 | Providing & Fixing of Aluminium window with 5 mm glass pans. |
| 58 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge |
| 59 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channelwith connecting clips made out of 2.64 mm dia x 230 mm long G.I.wire at every junction, including fixing perimeter channels 0.5 mm |
| 60 | thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings,pecification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 61 | 12.5 mm thick tapered edge gypsum moisture resistant board |
| 62 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applyinga priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 63 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm overan under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 64 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 65 | Foundations, footings, bases of columns, etc. for mass concrete |
| 66 | Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
| 67 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 68 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 69 | INTERNAL W/S AND SANITATION |
| 70 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 71 | W.C. pan with ISI marked white solid plastic seat and lid |
| 72 | Providing and fixing white vitreous chinaextended wall mounting type water closet of size 780x370x690 mm of approved shape including providing & fixing white viterous china cistern with dual flush fittings of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litres ) includung seat cover & cistern fittings nuts , bolts and gaskets etc complete. |
| 73 | Providing & fixing toilet paper holder |
| 74 | C.P. brass |
| 75 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 76 | Providing and fixing Jaquar Make Hand Shower (Health Faucet) with 8mm Dia,1.2 Meter Long Flexible Tube & Wall Hook of quality and make as approved by Engineer - in - charge. |
| 77 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 78 | White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap |
| 79 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- |
| 80 | (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 81 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 82 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 83 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 84 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 85 | Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern & jet) |
| 86 | 15 mm nominal bore |
| 87 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 88 | 45 cm length |
| 89 | 15 mm nominal bore |
| 90 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
| 91 | 100 mm diameter |
| 92 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 93 | 15 mm nominal bore |
| 94 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. |
| 95 | 15 mm nominal dia |
| 96 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 97 | 600 mm long towel rail with total length of 645 mm, width78 mm and effective height of 88 mm, weighing not lessthan 190 gms. |
| 98 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 99 | Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever required |
| 100 | Kitchen sink with drain board |
| 101 | 510x1040 mm bowl depth 200 mm |
| 102 | Kitchen sink without drain board |
| 103 | 610x510 mm bowl depth 200 mm |
| 104 | Providing & fixing PVC waste pipe for sink including PVC waste fittings Complete |
| 105 | Flexible Pipe |
| 106 | 32mm Dia |
| 107 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 108 | 15mm nominal bore |
| 109 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 110 | 15mm nominal bore |
| 111 | Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. |
| 112 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (Including C.I. trap for standard urinal with vent arm with operating and other couplings in C.P.brass: 50 mm dia) |
| 113 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as perdirection of Engineer-in-charge and finished smooth. |
| 114 | Granite Stone of approved shade |
| 115 | Providing and fixing of Kent Elite Plus Water Purifier (RO+UV+UF+TDS Control) with flow rate (50L/hr)including all its accessories, complete in all respect including testing etc. |
| 116 | Providing and fixing of Water Cooler (Voltas Make) including all its accessories, complete in all respect including testing etc. |
| 117 | Providing and fixing of storage type (pressurised type) electrichot water heater copper sheet container, 25 mm thickinsulation, stove enamelled M.S. jacket thermostatically controlled immersion heater with pilot neon lamp, suitable length of electrical cable and 15 amp 3 pin plug top, complete in all respect including testing etc. |
| 118 | Capacity 25 Liters |
| 119 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 120 | Concealed work, including cutting chases and making good the walls etc. |
| 121 | For Internal Toilet |
| 122 | 15 mm nominal outer dia Pipes |
| 123 | 20 mm nominal outer dia Pipes |
| 124 | 25 mm nominal outer dia Pipes |
| 125 | 32 mm nominal outer dia Pipes |
| 126 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 127 | Internal work - Exposed on wall |
| 128 | 20 mm nominal bore |
| 129 | 25 mm nominal bore |
| 130 | 32 mm nominal bore |
| 131 | 40 mm nominal bore |
| 132 | Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall |
| 133 | Terrace loop & Tank Filling Pipe |
| 134 | 20 mm nominal bore |
| 135 | 25 mm nominal bore |
| 136 | 32 mm nominal bore |
| 137 | 40 mm nominal bore |
| 138 | 50 mm nominal bore |
| 139 | 65 mm nominal bore |
| 140 | 80 mm nominal bore |
| 141 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : |
| 142 | 20mm diameter pipe |
| 143 | 25mm diameter pipe |
| 144 | 32mm diameter pipe |
| 145 | 40mm diameter pipe |
| 146 | 50mm diameter pipe |
| 147 | 65mm diameter pipe |
| 148 | 80mm diameter pipe |
| 149 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : |
| 150 | 20mm diameter pipe |
| 151 | 25mm diameter pipe |
| 152 | 32mm diameter pipe |
| 153 | 40mm diameter pipe |
| 154 | 50mm diameter pipe |
| 155 | 65mm diameter pipe |
| 156 | 80mm diameter pipe |
| 157 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 158 | For vertical pipe connection with terrace ringmain |
| 159 | 20 mm nominal bore |
| 160 | 25mm nominal bore |
| 161 | 32mm nominal bore |
| 162 | 40mm nominal bore |
| 163 | 50mm nominal bore |
| 164 | 65mm nominal bore |
| 165 | 80mm nominal bore |
| 166 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 167 | 25 to 40 mm nominal bore |
| 168 | 50 to 80 mm nominal bore |
| 169 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./H.P.H.D. plastic ball. |
| 170 | 25 mm nominal bore, 152 mm long, weighing not less than 440 gms |
| 171 | 40 mm nominal bore, 206 mm long, weighing not less than 690 gms |
| 172 | 50 mm nominal bore, 242 mm long, weighing not less than 1240 gms |
| 173 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 174 | Providing, Fixing, Testing & Commissioning of XLPE Insulation of 9mm thickness on hot water supply pipes. Astral orequivalent approved complete in all respect as directed by Engineer-in-charge. |
| 175 | 15mm dia (9 mm thickness) |
| 176 | 20mm dia (9 mm thickness) |
| 177 | 25mm dia (9 mm thickness) |
| 178 | 32mm dia (9 mm thickness) |
| 179 | 40mm dia (9 mm thickness) |
| 180 | 50mm dia (9 mm thickness) |
| 181 | Supply, fixing, testing and commissioning of following Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve - IP65CB - 230VAC, as per specifications:- |
| 182 | Lehry Make Automatic OHT Level Control System Consist of Following Items |
| 183 | 1) LEHRY Make On-Off Type Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve with CI Body & SS Disc 2) Level Float Switch- 5M 3) Control Box (a) IP 65 Finishing(250 x 160 x 115)mm (b) LED Lamps: Tank FULL, Tank EMPTY, Power (c) Power supply toggle switch (d) Accepts 230V Single Phase power supply and provides 24VAC to float switch and 230VAC to valve coil. (e) Accepts NO/NC feedback from float switch. |
| 184 | 40mm |
| 185 | 50mm |
| 186 | 65mm |
| 187 | 80mm |
| 188 | Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mmof suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. |
| 189 | 25mm dia. |
| 190 | 32mm dia. |
| 191 | 40mm dia. |
| 192 | 50mm dia. |
| 193 | 65mm dia. |
| 194 | 80mm dia. |
| 195 | 100mm dia. |
| 196 | 150mm dia. |
| 197 | 200mm dia. |
| 198 | 250mm dia. |
| 199 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 200 | 110 mm dia (for rain water) |
| 201 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion. |
| 202 | Single Push Fit Coupler |
| 203 | 110 mm dia |
| 204 | Single tee with door |
| 205 | 110x110x110 mm |
| 206 | Plain bend 87.5 deg |
| 207 | 110 mm dia |
| 208 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 209 | 110 mm dia |
| 210 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 211 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. |
| 212 | All kind of soil |
| 213 | Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. |
| 214 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: |
| 215 | 100mm dia SWpipe |
| 216 | Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. |
| 217 | Internal Toilet (Soil & Waste Pipe) |
| 218 | 75 mm |
| 219 | 110 mm |
| 220 | Exposed on Wall (Soil & Waste Pipe) |
| 221 | 110 mm |
| 222 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. |
| 223 | Bend without door (45°) |
| 224 | 75mm |
| 225 | 110mm |
| 226 | Bend without door (87.5°) |
| 227 | 75mm bend |
| 228 | 110mm |
| 229 | Y\" Fitting without door |
| 230 | 75mm |
| 231 | 110mm |
| 232 | Single Tee without door |
| 233 | 75mm |
| 234 | 110 mm |
| 235 | Single Tee with door |
| 236 | 75mm |
| 237 | 110 mm |
| 238 | Bend with door (87.5°) |
| 239 | 75mm |
| 240 | 110 mm |
| 241 | Clean Out Plug (COP) |
| 242 | 75mm |
| 243 | 110 mm |
| 244 | Reduced \"Y\" Fitting without door |
| 245 | 110mm x 75mm |
| 246 | Reduced Tee with door |
| 247 | 110mm x 75mm |
| 248 | Coupler |
| 249 | 75mm |
| 250 | 110mm |
| 251 | Vent Cowl |
| 252 | 110mm |
| 253 | Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. |
| 254 | For Wash basin & Urinal |
| 255 | 32mm dia. Pipe |
| 256 | 50mm dia. pipe |
| 257 | Elbow (45°) |
| 258 | 32mm |
| 259 | 50mm |
| 260 | Elbow (90°) |
| 261 | 32mm |
| 262 | 50mm |
| 263 | T fitting |
| 264 | 32mm |
| 265 | 50mm |
| 266 | Coupler |
| 267 | 32mm |
| 268 | 50mm |
| 269 | Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. |
| 270 | 110mm x 75mm x 50mm/40mm (Toilet) |
| 271 | Providing, fixing, jointing and testing , ofPVC NahaniTrap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. |
| 272 | 110mm x 75mm (Toilet & Kitchen) |
| 273 | Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap Adaptor (Height Riser), making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. |
| 274 | 110mm x 50mm/40mm |
| 275 | Providing and fixing PTMT grating of approved quality and colour. |
| 276 | Rectangular type with openable circular lid |
| 277 | 150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony) |
| 278 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : |
| 279 | 150 x 100mm size P-type |
| 280 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 281 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: |
| 282 | 100 mm diameter |
| 283 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. |
| 284 | All kind of soil |
| 285 | Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. |
| 286 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: |
| 287 | 100mm dia SWpipe |
| 288 | INTERNAL ELECTRIFICATION WORK |
| 289 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 290 | Group - C |
| 291 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 292 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 293 | Group -A |
| 294 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 295 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 296 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 297 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 298 | 2 X 6 sq. mm + 1 X 4 sq. mm earth wire |
| 299 | 2 x 10 sq.mm + 1 x 6sq.mm. earth wire |
| 300 | 2 x 16 sq.mm + 1 x 6sq.mm. earth wire |
| 301 | 4 x 6 sq.mm + 2 x 6 sq.mm. earth wire |
| 302 | 4 x 10 sq.mm + 2 x 6 sq.mm. earth wire |
| 303 | 4 x 16 sq.mm + 2 x 6sq.mm. earth wire |
| 304 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 305 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 306 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 307 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 308 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 309 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 310 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 311 | 5/6 A switch |
| 312 | 3 pin 5/6 A socket outlet |
| 313 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 314 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 315 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 316 | Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 317 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required |
| 318 | Upto 450 mm sweep |
| 319 | Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. |
| 320 | Supply of Recessed mounting 2x2 feet 36W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. |
| 321 | Supply of Recess mounting 2x2 feet 24 to 30W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. |
| 322 | Supply of LED 4ft 40W LED Tube light with a nominal system lumen output of 4000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 3000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 42W (including driver). |
| 323 | Supply of Suspended mounting 36W LED Liner Batten Light, suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. |
| 324 | Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 21W (including driver). |
| 325 | Supply of Recess mounting round 6 Watt 10 Watt , LED Down Lighter, suitable for 24Hr Continuous Operation, 660-1100 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. |
| 326 | Supply of Recess mounting round 12 Watt 15 Watt ,suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect |
| 327 | Supply of Recess mounting square 20 Watt , suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. |
| 328 | Supplying of Bead Head light 31W fitting complete including connections etc. |
| 329 | Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.complete in all respect |
| 330 | Supplying of LED mirror light luminaire with 10Wwatt complete with electronic ballast, lamp including connection etc. complete as required. |
| 331 | Supply of LED Flood light 50 Watt , suitable for 24Hr Continuous Operation, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, CCT 3000K, complete in all respect, |
| 332 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 333 | Supplying of 9 Watt 4 Star LED Wall Light Blub complete in all respect. |
| 334 | Supplying of 9 Watt Decorative LED Wall Light complete in all respect. |
| 335 | S & F cast Step light complete as required. Step Light31435, Anthracite grey, Aluminium, 104x104x35,LED Integrated3W, 50lm/3000K, Make Philips or Equivalent |
| 336 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan |
| 337 | Supplying, erection, connecting, testing and commissioning of 400 mm Wall Fancomplete in all respect. |
| 338 | Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required. |
| 339 | 300mm EXHAUST FAN |
| 340 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required |
| 341 | 40 A,25KA,FP MCCB |
| 342 | 63 A,25KA,FP MCCB |
| 343 | 100 A,30KA,FPMCCB |
| 344 | 125 A,36KA,FPMCCB |
| 345 | 160 A,25KA,FP MCCB |
| 346 | 200 A, 36KA,FPMCCB |
| 347 | 250 A, 36KA,FPMCCB |
| 348 | 320 A, 36KA,FPMCCB |
| 349 | Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 350 | 6 Way Double Door |
| 351 | 8 way, Double door |
| 352 | 12 way, Double Door |
| 353 | 16 way, Double Door |
| 354 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 355 | 4 Way Double door |
| 356 | 6 way Double door |
| 357 | 8 way Double door |
| 358 | 12 way Double door |
| 359 | Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.) |
| 360 | 4 way (4 + 12), Double door |
| 361 | 8 way (4 + 24), Double door |
| 362 | Supplying and fixing TP/FP sheet steel enclosure on surface/ recess. Suitable for upto 125 A 415 V MCCB complete with connections, testing and commissioning etc. as required. |
| 363 | Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 364 | 40 amps SP MCB |
| 365 | 40 amps DP MCB |
| 366 | 63 amps DP MCB |
| 367 | 40 amps TP MCB |
| 368 | 63 amps TP MCB |
| 369 | 40 amps 4P MCB |
| 370 | 63 amps 4P MCB |
| 371 | 100 amps 4P MCB |
| 372 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 373 | 40 amps |
| 374 | 63 amps |
| 375 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 376 | 40 amps |
| 377 | 63 amps |
| 378 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required. |
| 379 | 25 amps |
| 380 | 40 amps |
| 381 | 63 amps |
| 382 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 383 | Single pole |
| 384 | Double pole |
| 385 | Triple pole |
| 386 | Triple pole and neutral |
| 387 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 388 | Supplying and fixing 1P LCD Energy Meter 5-30A with BOX |
| 389 | Supplying and fixing 3Ph 4 W kWh Dir base mtg 240V 10- 60 A Energy Meter |
| 390 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 391 | Supplying and fixing DP sheet steel enclosure on surface/ recessalong with 25/32 A 240 V \"C\" curve DP MCB complete withconnections, testing and commissioning etc. as required. |
| 392 | Supplying and fixing 4P sheet steel enclosure on surface/ recess complete with connections, testing and commissioning etc. as required. |
| 393 | Supplying and fixing TP/FP sheet steel enclosure on surface/ recess. Suitable for upto 125 A 415 V MCCB complete with connections, testing and commissioning etc. as required. |
| 394 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 395 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 396 | SUBHEAD: - IV - EARTHING |
| 397 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each |
| 398 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 399 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required |
| 400 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 401 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 402 | Providing and laying earth connection from earth electrodewith 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earthelectrode including connection with G.I. thimble excavation andre-filling as required. |
| 403 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 404 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 405 | Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes: |
| 406 | 2 Pair (4 core) |
| 407 | Providing, laying, connecting and testing of multi-core telephone armoured cable of conductor size 0.5mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable along wall or ceiling or through existing pipe. |
| 408 | 100 Pair telephone cable |
| 409 | 50 Pair telephone cable |
| 410 | 20 Pair telephone cable |
| 411 | 10 Pair telephone cable |
| 412 | 5 Pair telephone cable |
| 413 | Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted. |
| 414 | 5 Pair tag block |
| 415 | 10 pair tag block |
| 416 | 20 pair tag block |
| 417 | 50 pair tag block |
| 418 | 100 pair tag block |
| 419 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 420 | 20mm dia PVC conduit |
| 421 | 25mm dia PVC conduit |
| 422 | 32mm dia PVC conduit |
| 423 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required |
| 424 | 1 or 2 Module (75mmX75mm) |
| 425 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 426 | Telephone socket outlet |
| 427 | TV antenna socket outlet |
| 428 | Bell Push |
| 429 | RJ-45 Data Socket outlet |
| 430 | Supplying and fixing call bell/ buzzer suitable for single phase,230 V, complete as required. |
| 431 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 432 | 1 run of cable |
| 433 | Providing, laying, connecting and testing of unarmoured TV cable RG-6 PVC insulated cable along wall or ceiling or through existing pipe. |
| 434 | Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 435 | Up to 35 sq.mm. |
| 436 | Above 35 sq.mm. and up to 95 sq.mm. |
| 437 | Above 95 sq.mm. and upto 185 sq.mm. |
| 438 | Above 185 sq.mm. and up to 400 sq.mm. |
| 439 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, rotective covering and refilling the trench etc as required |
| 440 | Up to 35 sq.mm. |
| 441 | Above 35 sq.mm. and up to 95 sq.mm. |
| 442 | Above 95 sq.mm. and upto 185 sq.mm. |
| 443 | Above 185 sq.mm. and up to 400 sq.mm. |
| 444 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 445 | Up to 35 sq.mm. |
| 446 | Above 35 sq.mm. and up to 95 sq.mm. |
| 447 | Above 95 sq.mm. and upto 185 sq.mm. |
| 448 | Above 185 sq.mm. and up to 400 sq.mm. |
| 449 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 450 | Up to 35 sq.mm. |
| 451 | Above 35 sq.mm. and up to 95 sq.mm. |
| 452 | Above 95 sq.mm. and upto 185 sq.mm. |
| 453 | Above 185 sq.mm. and up to 400 sq.mm. |
| 454 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required |
| 455 | Up to 35 sq.mm. |
| 456 | Above 35 sq.mm. and up to 95 sq.mm. |
| 457 | Above 95 sq.mm. and upto 185 sq.mm. |
| 458 | Above 185 sq.mm. and up to 400 sq.mm. |
| 459 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required |
| 460 | Upto 35 sq. mm (clamped with 1mm thick saddle |
| 461 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp |
| 462 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp |
| 463 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 464 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. |
| 465 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 466 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 467 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 468 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 469 | Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment |
| 470 | 3.5 x 400 sq.mm. |
| 471 | 3.5 x 300 sq.mm. |
| 472 | 3.5 x 240 sq.mm. |
| 473 | 3.5 x 185 sq.mm |
| 474 | 3.5 x 150 sq.mm |
| 475 | 3.5 x 120 sq.mm |
| 476 | 3.5 x 95 sq.mm |
| 477 | 3.5 x 70 sq.mm |
| 478 | 3.5 x 50 sq.mm |
| 479 | 3.5 x 35 sq.mm |
| 480 | 3.5 x 25 sq.mm. |
| 481 | 4 x 25 sq.mm |
| 482 | 4 x 16 sq.mm |
| 483 | 4 x 10 sq.mm |
| 484 | 4 x 6 sq.mm |
| 485 | 2 x 16 sq.mm, |
| 486 | 2 x 10 sq.mm, |
| 487 | 2 x 6 sq.mm, |
| 488 | Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. |
| 489 | 2 X 6 sq. mm (19mm) |
| 490 | 2 X 10 sq. mm (19mm) |
| 491 | 2 X 16 sq. mm (22mm) |
| 492 | 3½ X 25 sq. mm (28mm) |
| 493 | 3½ X 35 sq. mm (32mm) |
| 494 | 3½ X 50 sq. mm (35mm) |
| 495 | 3½ X 70 sq. mm (38mm) |
| 496 | 3½ X 95 sq. mm (45mm) |
| 497 | 3½ X 120 sq. mm (45mm) |
| 498 | 3½ X 150 sq. mm (50mm) |
| 499 | 3½ X 185 sq. mm (57mm) |
| 500 | 3½ X 225 sq. mm (62mm) |
| 501 | 3½ X 240 sq. mm (62mm) |
| 502 | 3½ X 300 sq. mm (70mm) |
| 503 | 3½ X 400 sq. mm (82mm) |
| 504 | 4 X 10 sq. mm (25mm) |
| 505 | 4 X 16 sq. mm (28mm) |
| 506 | Providing, laying and fixing following dia G.I. pipe (mediumclass) in ground complete with G.I. fittings including trenching(75 cm deep)and re-filling etc as required |
| 507 | 100 mm dia |
| 508 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. |
| 509 | 100mm dia |
| 510 | 150 mm dia |
| 511 | 250 mm dia |
| 512 | 300 mm dia |
| 513 | Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioningand protective covering etc., complete as required. |
| 514 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 515 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 516 | 100 mm wide x 50 mm depth x 1.6 mm thickness. |
| 517 | 150 mm wide x 50 mm depth x 1.6 mm thickness. |
| 518 | 300 mm wide x 50 mm depth x 1.6 mm thickness. |
| 519 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \"bends\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 520 | 100 mm wide x 50 mm depth x 1.6 mm thickness. |
| 521 | ACCOMMODATION CATEGORY -I (EACH WITH 2 ROOMS) Civil (03 Nos) |
| 522 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 523 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. |
| 524 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 525 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.. |
| 526 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) |
| 527 | Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface ofthe substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete:With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration |
| 528 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 529 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) [ M-20 ] |
| 530 | All works upto plinth level |
| 531 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 532 | All works Above plinth level |
| 533 | M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 534 | Providing and laying damp-proof course 25 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). |
| 535 | Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 536 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 537 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 538 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 539 | Cement mortar 1:4 (1 cement :4 coarse sand) |
| 540 | Extra for forming cavity 5 cm to 11.5 cm wide in cavity walls with necessary weep and vent holes including use of cores and cost of providing and fixing bitumastic coated M .S. ties 300 mm long of 25x3 mm section at not less than 3 ties per sqm as per approved design. |
| 541 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. |
| 542 | Providing machine made Wire Cut Bricks where edges are sharp and borders are straight and Size of8.5\"x 4\"x3\"having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%. Thickness of 230mm wall |
| 543 | Supply and Laying a water soluble penetrative solution for waterproofing of masonry building material & Nano technology based as it provides molecular level hydrophobicity to inorganic substrate .The product is based on organosilicon chemistry, hence reacts with the inorganic substrate surface, seals the surface uto a depth of 2-3 mm and provides long service life where Nano size allows penetration deep into substrate that provides 20+ years water repellency.(Zycosil/Pratt & Lamber or Equivalent) including cost of all materials, labour tools and plants etc. required for proper completion of the work. |
| 544 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. (TMT Fe-500) |
| 545 | 15mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand of 2.25 F.M. |
| 546 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand |
| 547 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand |
| 548 | 12mm thick plaster in 1:3 on ceiling and soffits of stairs upto floor two level. |
| 549 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any Size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 550 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to 1S:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily,Glazed Vitrified tiles Matt/Antiskid finish of size 600 x 600 mm |
| 551 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, inskirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 552 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm. Granite stone slab of all colour and texture |
| 553 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor). |
| 554 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 555 | (a) Single leaf |
| 556 | (b) Double leaf |
| 557 | Both side laminated |
| 558 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin-charge.Extruded section profile size 48x40 mm |
| 559 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash andmullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. |
| 560 | Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speeds Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. |
| 561 | Using R4 series with frame (115 mm & above) x (45 mm & above) & both glazed and fly screen sash (44 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coatedhandle on every glazed panel along with multipoint locking system. (Height above 1.8m) |
| 562 | Wall Painting with plastic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats (For Internal wall surface) |
| 563 | Wall Painting with plastic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats (For Internal ceiling surface) |
| 564 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 565 | Natural Mud plaster+ paint Aggregate made up of Lime, Clay & Additives in given proportion to get the desired Texture.Shade, Texture and number of coatsas per architects approval to get the desired finished |
| 566 | Cost of Artistic Mural & painting as per Design received from Architect Incharge. |
| 567 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to |
| 568 | IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick |
| 569 | jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 570 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 571 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . |
| 572 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete |
| 573 | (a) 300 mm x 10mm |
| 574 | (b) 200 x 10mm |
| 575 | Providing and fixing stainless steel handles with screws etc. complete (a) 150 mm |
| 576 | Float glass panes 4 mm thick glass pane (weight not less than 10 kg/sqm). |
| 577 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 578 | Foundations, footings, bases of columns, etc. for mass concrete |
| 579 | Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
| 580 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 581 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 582 | Supply & fixing clay tiles of 10X16 inches on roof including the cost of Ridge, typical caly tile, edge tiles and inlcusion of glass tiles in color and finish as per drawing approved from Architect in charge, and supply of all materials labours & tools etc required for safe erection and cost of adhesive, waterproof membrane and MS frame of L profile/rectangular hollow sections required for fixing and supprting the tiles., also includes the cost of all the necessary fitting and required for completion of the work as per Engineer in charge. |
| 583 | INTERNAL W/S AND SANITATION (03 Nos) |
| 584 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 585 | W.C. pan with ISI marked white solid plastic seat and lid |
| 586 | Providing and fixing white vitreous chinaextended wall mounting type water closet of size 780x370x690 mm of approved shape including providing & fixing white viterous china cistern with dual flush fittings of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litres ) includung seat cover & cistern fittings nuts , bolts and gaskets etc complete. |
| 587 | Providing & fixing toilet paper holder |
| 588 | C.P. brass |
| 589 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 590 | Providing and fixing Jaquar Make Hand Shower (Health Faucet) with 8mm Dia,1.2 Meter Long Flexible Tube & Wall Hook of quality and make as approved by Engineer - in - charge. |
| 591 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 592 | White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap |
| 593 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- |
| 594 | (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 595 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 596 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 597 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 598 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 599 | Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern & jet) |
| 600 | 15 mm nominal bore |
| 601 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 602 | 45 cm length |
| 603 | 15 mm nominal bore |
| 604 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
| 605 | 100 mm diameter |
| 606 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 607 | 15 mm nominal bore |
| 608 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. |
| 609 | 15 mm nominal dia |
| 610 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 611 | 600 mm long towel rail with total length of 645 mm, width78 mm and effective height of 88 mm, weighing not lessthan 190 gms. |
| 612 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 613 | Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever required |
| 614 | Kitchen sink with drain board |
| 615 | 510x1040 mm bowl depth 200 mm |
| 616 | Kitchen sink without drain board |
| 617 | 610x510 mm bowl depth 200 mm |
| 618 | Providing & fixing PVC waste pipe for sink including PVC waste fittings Complete |
| 619 | Flexible Pipe |
| 620 | 32mm Dia |
| 621 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 622 | 15mm nominal bore |
| 623 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 624 | 15mm nominal bore |
| 625 | Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. |
| 626 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (Including C.I. trap for standard urinal with vent arm with operating and other couplings in C.P.brass: 50 mm dia) |
| 627 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as perdirection of Engineer-in-charge and finished smooth. |
| 628 | Granite Stone of approved shade |
| 629 | Providing and fixing of Kent Elite Plus Water Purifier (RO+UV+UF+TDS Control) with flow rate (50L/hr)including all its accessories, complete in all respect including testing etc. |
| 630 | Providing and fixing of Water Cooler (Voltas Make) including all its accessories, complete in all respect including testing etc. |
| 631 | Providing and fixing of storage type (pressurised type) electrichot water heater copper sheet container, 25 mm thickinsulation, stove enamelled M.S. jacket thermostatically controlled immersion heater with pilot neon lamp, suitable length of electrical cable and 15 amp 3 pin plug top, complete in all respect including testing etc. |
| 632 | Capacity 25 Liters |
| 633 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 634 | Concealed work, including cutting chases and making good the walls etc. |
| 635 | For Internal Toilet |
| 636 | 15 mm nominal outer dia Pipes |
| 637 | 20 mm nominal outer dia Pipes |
| 638 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 639 | Internal work - Exposed on wall |
| 640 | 20 mm nominal bore |
| 641 | 25 mm nominal bore |
| 642 | 32 mm nominal bore |
| 643 | 40 mm nominal bore |
| 644 | Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall |
| 645 | Terrace loop & Tank Filling Pipe |
| 646 | 20 mm nominal bore |
| 647 | 25 mm nominal bore |
| 648 | 32 mm nominal bore |
| 649 | 40 mm nominal bore |
| 650 | 50 mm nominal bore |
| 651 | 65 mm nominal bore |
| 652 | 80 mm nominal bore |
| 653 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : |
| 654 | 20mm diameter pipe |
| 655 | 25mm diameter pipe |
| 656 | 32mm diameter pipe |
| 657 | 40mm diameter pipe |
| 658 | 50mm diameter pipe |
| 659 | 65mm diameter pipe |
| 660 | 80mm diameter pipe |
| 661 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : |
| 662 | 20mm diameter pipe |
| 663 | 25mm diameter pipe |
| 664 | 32mm diameter pipe |
| 665 | 40mm diameter pipe |
| 666 | 50mm diameter pipe |
| 667 | 65mm diameter pipe |
| 668 | 80mm diameter pipe |
| 669 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 670 | For vertical pipe connection with terrace ringmain |
| 671 | 20 mm nominal bore |
| 672 | 25mm nominal bore |
| 673 | 32mm nominal bore |
| 674 | 40mm nominal bore |
| 675 | 50mm nominal bore |
| 676 | 65mm nominal bore |
| 677 | 80mm nominal bore |
| 678 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 679 | 25 to 40 mm nominal bore |
| 680 | 50 to 80 mm nominal bore |
| 681 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./H.P.H.D. plastic ball. |
| 682 | 15 mm nominal bore, 105 mm long, weighing not less than 138 gms |
| 683 | 20 mm nominal bore, 120 mm long, weighing not less than 198 gms |
| 684 | 25 mm nominal bore, 152 mm long, weighing not less than 440 gms |
| 685 | 40 mm nominal bore, 206 mm long, weighing not less than 690 gms |
| 686 | 50 mm nominal bore, 242 mm long, weighing not less than 1240 gms |
| 687 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 688 | Providing, Fixing, Testing & Commissioning of XLPE Insulation of 9mm thickness on hot water supply pipes. Astral orequivalent approved complete in all respect as directed by Engineer-in-charge. |
| 689 | 15mm dia (9 mm thickness) |
| 690 | 20mm dia (9 mm thickness) |
| 691 | 25mm dia (9 mm thickness) |
| 692 | 32mm dia (9 mm thickness) |
| 693 | 40mm dia (9 mm thickness) |
| 694 | 50mm dia (9 mm thickness) |
| 695 | Supply, fixing, testing and commissioning of following Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve - IP65CB - 230VAC, as per specifications:- |
| 696 | Lehry Make Automatic OHT Level Control System Consist of Following Items |
| 697 | 1) LEHRY Make On-Off Type Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve with CI Body & SS Disc 2) Level Float Switch- 5M 3) Control Box (a) IP 65 Finishing(250 x 160 x 115)mm (b) LED Lamps: Tank FULL, Tank EMPTY, Power (c) Power supply toggle switch (d) Accepts 230V Single Phase power supply and provides 24VAC to float switch and 230VAC to valve coil. (e) Accepts NO/NC feedback from float switch. |
| 698 | 40mm |
| 699 | 50mm |
| 700 | 65mm |
| 701 | 80mm |
| 702 | Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mmof suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. |
| 703 | 25mm dia. |
| 704 | 32mm dia. |
| 705 | 40mm dia. |
| 706 | 50mm dia. |
| 707 | 65mm dia. |
| 708 | 80mm dia. |
| 709 | 100mm dia. |
| 710 | 150mm dia. |
| 711 | 200mm dia. |
| 712 | 250mm dia. |
| 713 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 714 | 110 mm dia (for rain water) |
| 715 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion. |
| 716 | Single Push Fit Coupler |
| 717 | 110 mm dia |
| 718 | Single tee with door |
| 719 | 110x110x110 mm |
| 720 | Plain bend 87.5 deg |
| 721 | 110 mm dia |
| 722 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 723 | 110 mm dia |
| 724 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 725 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. |
| 726 | All kind of soil |
| 727 | Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. |
| 728 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: |
| 729 | 100mm dia SWpipe |
| 730 | Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. |
| 731 | Internal Toilet (Soil & Waste Pipe) |
| 732 | 75 mm |
| 733 | 110 mm |
| 734 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. |
| 735 | Bend without door (45°) |
| 736 | 75mm |
| 737 | 110mm |
| 738 | Bend without door (87.5°) |
| 739 | 75mm bend |
| 740 | 110mm |
| 741 | Y\" Fitting without door |
| 742 | 75mm |
| 743 | 110mm |
| 744 | Single Tee without door |
| 745 | 75mm |
| 746 | 110 mm |
| 747 | Single Tee with door |
| 748 | 75mm |
| 749 | 110 mm |
| 750 | Bend with door (87.5°) |
| 751 | 75mm |
| 752 | 110 mm |
| 753 | Clean Out Plug (COP) |
| 754 | 75mm |
| 755 | 110 mm |
| 756 | Reduced \"Y\" Fitting without door |
| 757 | 110mm x 75mm |
| 758 | Reduced Tee with door |
| 759 | 110mm x 75mm |
| 760 | Coupler |
| 761 | 75mm |
| 762 | 110mm |
| 763 | Vent Cowl |
| 764 | 110mm |
| 765 | Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. |
| 766 | For Wash basin & Urinal |
| 767 | 32mm dia. Pipe |
| 768 | Elbow (45°) |
| 769 | 32mm |
| 770 | Elbow (90°) |
| 771 | 32mm |
| 772 | T fitting |
| 773 | 32mm |
| 774 | 50mm |
| 775 | Coupler |
| 776 | 32mm |
| 777 | Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. |
| 778 | 110mm x 75mm x 50mm/40mm (Toilet) |
| 779 | Providing, fixing, jointing and testing , ofPVC NahaniTrap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. |
| 780 | 110mm x 75mm (Toilet & Kitchen) |
| 781 | Providing and fixing PTMT grating of approved quality and colour. |
| 782 | Rectangular type with openable circular lid |
| 783 | 150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony) |
| 784 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : |
| 785 | 150 x 100mm size P-type |
| 786 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 787 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: |
| 788 | 100 mm diameter |
| 789 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. |
| 790 | All kind of soil |
| 791 | Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. |
| 792 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: |
| 793 | 100mm dia SWpipe |
| 794 | INTERNAL ELECTRIFICATION WORK 03 Nos |
| 795 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 796 | Group - C |
| 797 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 798 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 799 | Group -A |
| 800 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 801 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 802 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 803 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 804 | 2 X 6 sq. mm + 1 X 4 sq. mm earth wire |
| 805 | 2 x 10 sq.mm + 1 x 6sq.mm. earth wire |
| 806 | 2 x 16 sq.mm + 1 x 6sq.mm. earth wire |
| 807 | 4 x 6 sq.mm + 2 x 6 sq.mm. earth wire |
| 808 | 4 x 10 sq.mm + 2 x 6 sq.mm. earth wire |
| 809 | 4 x 16 sq.mm + 2 x 6sq.mm. earth wire |
| 810 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 811 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 812 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 813 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 814 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 815 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 816 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 817 | 5/6 A switch |
| 818 | 3 pin 5/6 A socket outlet |
| 819 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 820 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 821 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 822 | Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 823 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required |
| 824 | Upto 450 mm sweep |
| 825 | Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. |
| 826 | Supply of Recessed mounting 2x2 feet 36W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. |
| 827 | Supply of Recess mounting 2x2 feet 24 to 30W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. |
| 828 | Supply of LED 4ft 40W LED Tube light with a nominal system lumen output of 4000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 3000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 42W (including driver). |
| 829 | Supply of Suspended mounting 36W LED Liner Batten Light, suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. |
| 830 | Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 21W (including driver). |
| 831 | Supply of Surface mounting round 6 Watt 10 Watt , LED Down Lighter, suitable for 24Hr Continuous Operation, 660-1100 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. |
| 832 | Supply of Recess mounting round 12 Watt 15 Watt ,suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect |
| 833 | Supply of Suspended/Surface mounting round 12 Watt 15 Watt Light,suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect |
| 834 | Supply of Recess mounting square 20 Watt , suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. |
| 835 | Supplying of Bead Head light 31W fitting complete including connections etc. |
| 836 | Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.complete in all respect |
| 837 | Supplying of LED mirror light luminaire with 10Wwatt complete with electronic ballast, lamp including connection etc. complete as required. |
| 838 | Supply of LED Flood light 50 Watt , suitable for 24Hr Continuous Operation, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, CCT 3000K, complete in all respect, |
| 839 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 840 | Supplying of 9 Watt 4 Star LED Wall Light Blub complete in all respect. |
| 841 | Supplying of 9 Watt Decorative LED Wall Light complete in all respect. |
| 842 | Supplying of 15 Watt decorative IP 66 LED UP-down Luminaire with wallsurface mounting using COB LED as light source. complete in all respect. |
| 843 | Supplying of 7 Watt Step Light complete in all respect. |
| 844 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan |
| 845 | Supplying, erection, connecting, testing and commissioning of 400 mm Wall Fancomplete in all respect. |
| 846 | Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required. |
| 847 | 300mm EXHAUST FAN |
| 848 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required |
| 849 | 40 A,25KA,FP MCCB |
| 850 | 63 A,25KA,FP MCCB |
| 851 | 100 A,30KA,FPMCCB |
| 852 | 125 A,36KA,FPMCCB |
| 853 | 160 A,25KA,FP MCCB |
| 854 | 200 A, 36KA,FPMCCB |
| 855 | 250 A, 36KA,FPMCCB |
| 856 | 320 A, 36KA,FPMCCB |
| 857 | Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 858 | 6 Way Double Door |
| 859 | 8 way, Double door |
| 860 | 12 way, Double Door |
| 861 | 16 way, Double Door |
| 862 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 863 | 4 Way Double door |
| 864 | 6 way Double door |
| 865 | 8 way Double door |
| 866 | 12 way Double door |
| 867 | Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.) |
| 868 | 4 way (4 + 12), Double door |
| 869 | 8 way (4 + 24), Double door |
| 870 | Supplying and fixing TP/FP sheet steel enclosure on surface/ recess. Suitable for upto 125 A 415 V MCCB complete with connections, testing and commissioning etc. as required. |
| 871 | Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 872 | 40 amps SP MCB |
| 873 | 40 amps DP MCB |
| 874 | 63 amps DP MCB |
| 875 | 40 amps TP MCB |
| 876 | 63 amps TP MCB |
| 877 | 40 amps 4P MCB |
| 878 | 63 amps 4P MCB |
| 879 | 100 amps 4P MCB |
| 880 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 881 | 40 amps |
| 882 | 63 amps |
| 883 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 884 | 40 amps |
| 885 | 63 amps |
| 886 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required. |
| 887 | 25 amps |
| 888 | 40 amps |
| 889 | 63 amps |
| 890 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 891 | Single pole |
| 892 | Double pole |
| 893 | Triple pole |
| 894 | Triple pole and neutral |
| 895 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 896 | Supplying and fixing 1P LCD Energy Meter 5-30A with BOX |
| 897 | Supplying and fixing 3Ph 4 W kWh Dir base mtg 240V 10- 60 A Energy Meter |
| 898 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 899 | Supplying and fixing DP sheet steel enclosure on surface/ recessalong with 25/32 A 240 V \"C\" curve DP MCB complete withconnections, testing and commissioning etc. as required. |
| 900 | Supplying and fixing 4P sheet steel enclosure on surface/ recess complete with connections, testing and commissioning etc. as required. |
| 901 | Supplying and fixing TP/FP sheet steel enclosure on surface/ recess. Suitable for upto 125 A 415 V MCCB complete with connections, testing and commissioning etc. as required. |
| 902 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 903 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 904 | Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.0mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCB\"s to be used.All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports. |
| 905 | The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. |
| 906 | The minimum clearances between bus bars shall be as follows : |
| 907 | Phase to phase - minimum 20mm |
| 908 | Phase to neutral-minimum 15mm |
| 909 | Main LT Panel |
| 910 | Incoming : |
| 911 | 1 No 630 Amp. 4P MCCB of 35KA (Ics=Icu)Breaking Capacity |
| 912 | 1 No 500 Amp. 4P MCCB of 35KA (Ics=Icu)Breaking Capacity |
| 913 | 2 No 630 Amp. 4P CONTRACTOR |
| 914 | Metering : |
| 915 | 2 Set of CT\"s one of 630/ 5Amp ratio for Multifunction Meter |
| 916 | 2 Set of CT\"s one of 630/ 5Amp ratio 27,47,59,81. |
| 917 | 2 Set of CT\"s one of 200/ 5Amp ratio for APFC relay. |
| 918 | 2 Set of Phase Indication Lamp. |
| 919 | Bus Coupler : |
| 920 | 1 No 630 Amp. 4P MCCB of 35KA (Ics=Icu)Breaking Capacity |
| 921 | 1 No 630 Amp. 4P CONTRACTOR |
| 922 | Bus Bar : |
| 923 | 2 No. 800 Amp. FP aluminimum bus bar of suitable length. |
| 924 | Outgoing : |
| 925 | Phase indication lamps on each outgoing to be provided. |
| 926 | 400 Amps FP MCCB of 35KA - 1 No |
| 927 | 320 Amps FP MCCB of 35KA - 2 No |
| 928 | 200 Amps FP MCCB of 35KA - 1 No |
| 929 | 125 Amps FP MCCB of 35KA - 4 No |
| 930 | 100 Amps FP MCCB of 35KA - 2 No |
| 931 | 63 Amps FP MCCB of 35KA - 4 No |
| 932 | 2 No. SPACE & SPARE |
| 933 | Panel described as above |
| 934 | CAPACITOR PANEL-100 KVAR |
| 935 | SITC APFC Panel of 100 KVAR capacity suitable for operation on 415 + 5% Volt, 3 Phase, 50Hz, AC supply, having MPP type, resin bounded, static5,10,15,25 KVAR capacitors (without oil) in tier formationcomplete with following TPN MCCBas incomer of the panel, 11 step microprocessor based power factor controller relay capable to select the rating from 1 KVAR to multiples thereon up to max rating of the panel, current limiting contactors for each capacitors protected with MCBs, Ammeter (Analogue type) with CTs, Voltmeter (Analogue type) selector switches indicating lights, cooling fans for panel, earthing the panel with 2 Nos. 25mm x 5mm thick GI steel flat from existing earth bar, connection of APFC panel with suitable size 3.5 core aluminium conductor armoured XLPE cable from main LT panel (maximum length of cable 10 mtrs.) and compression glands etc. as reqd. The panel should have provision of timer based circuit in APFC relay to switch ON and OFF the static part automatically as and when requried. Capacity of Static capacitors should be accommodated from the overall rating of the panel and should be designed to switch in |
| 936 | independently. The panel should be manufactured with 1.6mm thick CRCA sheet duly powder coated. |
| 937 | Incoming |
| 938 | One (1) No 200 Amp. 4P MCCB of 25 KABreaking capacity |
| 939 | BUS BAR |
| 940 | 1 Set of 300 Amps TPN Aluminium Bus Bars |
| 941 | OUT GOING |
| 942 | 02 No. 63 Amps. TP MCCB (25 KA)-25 KVAR |
| 943 | 01 No. 40 Amps. TP MCCB (25 KA)-15 KVAR |
| 944 | 03 No. 32 Amps. TP MCCB (25 KA)- 10 KVAR |
| 945 | 01 No. 25 Amps. TP MCCB (25 KA)- 5 KVAR |
| 946 | Panel described as above |
| 947 | STREET LIGHT PANEL (OUTDOOR TYPE) IP 65 |
| 948 | Incoming : |
| 949 | One (1) No 63 Amp. 4P MCCB of 25KABreaking capacity |
| 950 | Metering : |
| 951 | One (1) No. SetsMultifunction Meter each incoming |
| 952 | One (1) No. of Phase Indication Lamp each incoming |
| 953 | Bus Bar : |
| 954 | One (1) No. 80 Amp.TPN aluminimum bus bar of suitable length. |
| 955 | Outgoing : |
| 956 | Phase indication lamps on each outgoing to be provided. |
| 957 | 2 No. 32 Amp 4PMCB. (10 KA) |
| 958 | 20 No. 16 Amp DPMCB. (10 KA) |
| 959 | 2 No. SPACE & SPARE |
| 960 | Panel described as above |
| 961 | Power Panel-LHS |
| 962 | Incoming : |
| 963 | 1 No 250 Amp. 4P MCCB of 25KABreaking capacity |
| 964 | Metering : |
| 965 | 1 Set of CT\"s one of 250/ 5Amp ratio for Multifunction Meter |
| 966 | One (1) Set of Phase Indication Lamp. |
| 967 | Bus Bar : |
| 968 | 1 No. 300 Amp.TPN aluminimum bus bar of suitable length. |
| 969 | Outgoing : |
| 970 | Phase indication lamps on each outgoing to be provided. |
| 971 | 3 No. 63 Amp 4PMCB |
| 972 | 6 No. 40 Amp 4PMCB |
| 973 | SPARE & SPACE- 2 No |
| 974 | Panel described as above |
| 975 | Power Panel-RHS |
| 976 | Incoming : |
| 977 | 1 No 320 Amp. 4P MCCB of 35KABreaking capacity |
| 978 | Metering : |
| 979 | 1 Set of CT\"s one of 320/ 5Amp ratio for Multifunction Meter |
| 980 | One (1) Set of Phase Indication Lamp. |
| 981 | Bus Bar : |
| 982 | 1 No. 400 Amp.TPN aluminimum bus bar of suitable length. |
| 983 | Outgoing : |
| 984 | Phase indication lamps on each outgoing to be provided. |
| 985 | 4 No. 100 Amp 4PMCB |
| 986 | 3 No. 63 Amp 4PMCB |
| 987 | 3 No. 40 Amp 4PMCB |
| 988 | SPARE & SPACE- 2 No |
| 989 | Panel described as above |
| 990 | Light Panel-LHS |
| 991 | Incoming : |
| 992 | 1 No 200 Amp. 4P MCCB of 25KABreaking capacity |
| 993 | Metering : |
| 994 | 1 Set of CT\"s one of 200/ 5Amp ratio for Multifunction Meter |
| 995 | One (1) Set of Phase Indication Lamp. |
| 996 | Bus Bar : |
| 997 | 1 No. 250 Amp.TPN aluminimum bus bar of suitable length. |
| 998 | Outgoing : |
| 999 | Phase indication lamps on each outgoing to be provided. |
| 1000 | 2 No. 63 Amp 4PMCB |
| 1001 | 7 No. 40 Amp 4PMCB |
| 1002 | SPARE & SPACE- 2 No |
| 1003 | Panel described as above |
| 1004 | Light Panel-RHS |
| 1005 | Incoming : |
| 1006 | 1 No 160 Amp. 4P MCCB of 25KABreaking capacity |
| 1007 | Metering : |
| 1008 | 1 Set of CT\"s one of 160/ 5Amp ratio for Multifunction Meter |
| 1009 | One (1) Set of Phase Indication Lamp. |
| 1010 | Bus Bar : |
| 1011 | 1 No. 200 Amp.TPN aluminimum bus bar of suitable length. |
| 1012 | Outgoing : |
| 1013 | Phase indication lamps on each outgoing to be provided. |
| 1014 | 1 No. 63 Amp 4PMCB |
| 1015 | 8 No. 40 Amp 4PMCB |
| 1016 | SPARE & SPACE- 2 No |
| 1017 | Panel described as above |
| 1018 | UPS PANEL |
| 1019 | Incoming : |
| 1020 | 2 No 125 Amp. 4P MCCB of 25KABreaking capacity |
| 1021 | Metering : |
| 1022 | 2 Set of CT\"s one of 125/ 5Amp ratio for Multifunction Meter |
| 1023 | 2 Set of Phase Indication Lamp. |
| 1024 | Bus Bar : |
| 1025 | One (1) No. 160 Amp.TPN aluminimum bus bar of suitable length. |
| 1026 | Outgoing : |
| 1027 | Phase indication lamps on each outgoing to be provided. |
| 1028 | 2 No. 63 Amp 4PMCB |
| 1029 | 8 No. 40 Amp 4PMCB |
| 1030 | 2 No. 40 Amp DPMCB |
| 1031 | SPARE & SPACE- 2 No |
| 1032 | Panel described as above |
| 1033 | ELEVATOR PANEL 1&2 |
| 1034 | Incoming : |
| 1035 | One (1) No 125 Amp. 4P MCCB of 25KABreaking capacity |
| 1036 | Metering : |
| 1037 | 1 Set of CT\"s one of 125/ 5Amp ratio for Multifunction Meter |
| 1038 | 1 Set of Phase Indication Lamp. |
| 1039 | Bus Bar : |
| 1040 | One (1) No. 200 Amp.TPN aluminimum bus bar of suitable length. |
| 1041 | Outgoing : |
| 1042 | Phase indication lamps on each outgoing to be provided. |
| 1043 | 3 No.63 Amp 4PMCCB. (25 KA) |
| 1044 | 3 No. 40 Amp DPMCB. (10 KA) |
| 1045 | SPARE & SPACE |
| 1046 | Panel described as above |
| 1047 | ELEVATOR PANEL 3 |
| 1048 | Incoming : |
| 1049 | One (1) No 80 Amp. 4P MCCB of 25KABreaking capacity |
| 1050 | Metering : |
| 1051 | 1 Set of CT\"s one of 80/ 5Amp ratio for Multifunction Meter |
| 1052 | 1 Set of Phase Indication Lamp. |
| 1053 | Bus Bar : |
| 1054 | One (1) No. 100 Amp.TPN aluminimum bus bar of suitable length. |
| 1055 | Outgoing : |
| 1056 | Phase indication lamps on each outgoing to be provided. |
| 1057 | 2 No.63 Amp 4PMCCB. (25 KA) |
| 1058 | 2 No.40 Amp DPMCB. (10 KA) |
| 1059 | SPARE & SPACE |
| 1060 | Panel described as above |
| 1061 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each |
| 1062 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 1063 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required |
| 1064 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 1065 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 1066 | Providing and laying earth connection from earth electrodewith 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earthelectrode including connection with G.I. thimble excavation andre-filling as required. |
| 1067 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 1068 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 1069 | Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes: |
| 1070 | 2 Pair (4 core) |
| 1071 | Providing, laying, connecting and testing of multi-core telephone armoured cable of conductor size 0.5mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable along wall or ceiling or through existing pipe. |
| 1072 | 100 Pair telephone cable |
| 1073 | 50 Pair telephone cable |
| 1074 | 20 Pair telephone cable |
| 1075 | 10 Pair telephone cable |
| 1076 | 5 Pair telephone cable |
| 1077 | Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted. |
| 1078 | 5 Pair tag block |
| 1079 | 10 pair tag block |
| 1080 | 20 pair tag block |
| 1081 | 50 pair tag block |
| 1082 | 100 pair tag block |
| 1083 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 1084 | 20mm dia PVC conduit |
| 1085 | 25mm dia PVC conduit |
| 1086 | 32mm dia PVC conduit |
| 1087 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required |
| 1088 | 1 or 2 Module (75mmX75mm) |
| 1089 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 1090 | Telephone socket outlet |
| 1091 | TV antenna socket outlet |
| 1092 | Bell Push |
| 1093 | RJ-45 Data Socket outlet |
| 1094 | Supplying and fixing call bell/ buzzer suitable for single phase,230 V, complete as required. |
| 1095 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 1096 | 1 run of cable |
| 1097 | Providing, laying, connecting and testing of unarmoured TV cable RG-6 PVC insulated cable along wall or ceiling or through existing pipe. |
| 1098 | Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 1099 | Up to 35 sq.mm. |
| 1100 | Above 35 sq.mm. and up to 95 sq.mm. |
| 1101 | Above 95 sq.mm. and upto 185 sq.mm. |
| 1102 | Above 185 sq.mm. and up to 400 sq.mm. |
| 1103 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, rotective covering and refilling the trench etc as required |
| 1104 | Up to 35 sq.mm. |
| 1105 | Above 35 sq.mm. and up to 95 sq.mm. |
| 1106 | Above 95 sq.mm. and upto 185 sq.mm. |
| 1107 | Above 185 sq.mm. and up to 400 sq.mm. |
| 1108 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 1109 | Up to 35 sq.mm. |
| 1110 | Above 35 sq.mm. and up to 95 sq.mm. |
| 1111 | Above 95 sq.mm. and upto 185 sq.mm. |
| 1112 | Above 185 sq.mm. and up to 400 sq.mm. |
| 1113 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 1114 | Up to 35 sq.mm. |
| 1115 | Above 35 sq.mm. and up to 95 sq.mm. |
| 1116 | Above 95 sq.mm. and upto 185 sq.mm. |
| 1117 | Above 185 sq.mm. and up to 400 sq.mm. |
| 1118 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required |
| 1119 | Up to 35 sq.mm. |
| 1120 | Above 35 sq.mm. and up to 95 sq.mm. |
| 1121 | Above 95 sq.mm. and upto 185 sq.mm. |
| 1122 | Above 185 sq.mm. and up to 400 sq.mm. |
| 1123 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required |
| 1124 | Upto 35 sq. mm (clamped with 1mm thick saddle |
| 1125 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp |
| 1126 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp |
| 1127 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 1128 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. |
| 1129 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 1130 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 1131 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 1132 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 1133 | Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment |
| 1134 | 3.5 x 400 sq.mm. |
| 1135 | 3.5 x 300 sq.mm. |
| 1136 | 3.5 x 240 sq.mm. |
| 1137 | 3.5 x 185 sq.mm |
| 1138 | 3.5 x 150 sq.mm |
| 1139 | 3.5 x 120 sq.mm |
| 1140 | 3.5 x 95 sq.mm |
| 1141 | 3.5 x 70 sq.mm |
| 1142 | 3.5 x 50 sq.mm |
| 1143 | 3.5 x 35 sq.mm |
| 1144 | 3.5 x 25 sq.mm. |
| 1145 | 4 x 25 sq.mm |
| 1146 | 4 x 16 sq.mm |
| 1147 | 4 x 10 sq.mm |
| 1148 | 4 x 6 sq.mm |
| 1149 | 3 x 6 sq.mm |
| 1150 | 2 x 16 sq.mm, |
| 1151 | 2 x 10 sq.mm, |
| 1152 | 2 x 6 sq.mm, |
| 1153 | Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. |
| 1154 | 2 X 6 sq. mm (19mm) |
| 1155 | 2 X 10 sq. mm (19mm) |
| 1156 | 2 X 16 sq. mm (22mm) |
| 1157 | 3½ X 25 sq. mm (28mm) |
| 1158 | 3½ X 35 sq. mm (32mm) |
| 1159 | 3½ X 50 sq. mm (35mm) |
| 1160 | 3½ X 70 sq. mm (38mm) |
| 1161 | 3½ X 95 sq. mm (45mm) |
| 1162 | 3½ X 120 sq. mm (45mm) |
| 1163 | 3½ X 150 sq. mm (50mm) |
| 1164 | 3½ X 185 sq. mm (57mm) |
| 1165 | 3½ X 225 sq. mm (62mm) |
| 1166 | 3½ X 240 sq. mm (62mm) |
| 1167 | 3½ X 300 sq. mm (70mm) |
| 1168 | 3½ X 400 sq. mm (82mm) |
| 1169 | 4 X 10 sq. mm (25mm) |
| 1170 | 4 X 16 sq. mm (28mm) |
| 1171 | Providing, laying and fixing following dia G.I. pipe (mediumclass) in ground complete with G.I. fittings including trenching(75 cm deep)and re-filling etc as required |
| 1172 | 100 mm dia |
| 1173 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. |
| 1174 | 100mm dia |
| 1175 | 150 mm dia |
| 1176 | 250 mm dia |
| 1177 | 300 mm dia |
| 1178 | Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioningand protective covering etc., complete as required. |
| 1179 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 1180 | Category-II (Civil (02) |
| 1181 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. |
| 1182 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. |
| 1183 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 1184 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. |
| 1185 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) |
| 1186 | Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface ofthe substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete:With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration |
| 1187 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 1188 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) [ M-20 ] |
| 1189 | All works upto plinth level |
| 1190 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 1191 | All works Above plinth level |
| 1192 | M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 1193 | Providing and laying damp-proof course 25 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size). |
| 1194 | Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 1195 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 1196 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 1197 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 1198 | Cement mortar 1:4 (1 cement :4 coarse sand) |
| 1199 | Extra for forming cavity 5 cm to 11.5 cm wide in cavity walls with necessary weep and vent holes including use of cores and cost of providing and fixing bitumastic coated M .S. ties 300 mm long of 25x3 mm section at not less than 3 ties per sqm as per approved design. |
| 1200 | Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry. |
| 1201 | Providing machine made Wire Cut Bricks where edges are sharp and borders are straight and Size of8.5\"x 4\"x3\"having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%. Thickness of 230mm wall |
| 1202 | Supply and Laying a water soluble penetrative solution for waterproofing of masonry building material & Nano technology based as it provides molecular level hydrophobicity to inorganic substrate .The product is based on organosilicon chemistry, hence reacts with the inorganic substrate surface, seals the surface uto a depth of 2-3 mm and provides long service life where Nano size allows penetration deep into substrate that provides 20+ years water repellency.(Zycosil/Pratt & Lamber or Equivalent) including cost of all materials, labour tools and plants etc. required for proper completion of the work. |
| 1203 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. (TMT Fe-500) |
| 1204 | 15mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand of 2.25 F.M. |
| 1205 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand |
| 1206 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand |
| 1207 | 12mm thick plaster in 1:3 on ceiling and soffits of stairs upto floor two level. |
| 1208 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any Size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 1209 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to 1S:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily,Glazed Vitrified tiles Matt/Antiskid finish of size 600 x 600 mm |
| 1210 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm |
| 1211 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm. Granite stone slab of all colour and texture |
| 1212 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor). |
| 1213 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 1214 | (a) Single leaf |
| 1215 | (b) Double leaf |
| 1216 | Both side laminated |
| 1217 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin- charge.Extruded section profile size 48x40 mm |
| 1218 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash andmullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. |
| 1219 | Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speeds Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. |
| 1220 | Using R4 series with frame (115 mm & above) x (45 mm & above) & both glazed and fly screen sash (44 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coatedhandle on every glazed panel along with multipoint locking system. (Height above 1.8m) |
| 1221 | Wall Painting with plastic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats (For Internal wall surface) |
| 1222 | Wall Painting with plastic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats (For Internal ceiling surface) |
| 1223 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 1224 | Natural Mud plaster+ paint Aggregate made up of Lime, Clay & Additives in given proportion to get the desired Texture.Shade, Texture and number of coatsas per architects approval to get the desired finished |
| 1225 | Cost of Artistic Mural & painting as per Design received from Architect Incharge. |
| 1226 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to |
| 1227 | IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick |
| 1228 | jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 1229 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 1230 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . |
| 1231 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete |
| 1232 | (a) 300 mm x 10mm |
| 1233 | (b) 200 x 10mm |
| 1234 | Providing and fixing stainless steel handles with screws etc. complete (a) 150 mm |
| 1235 | Float glass panes 4 mm thick glass pane (weight not less than 10 kg/sqm). |
| 1236 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 1237 | Foundations, footings, bases of columns, etc. for mass concrete |
| 1238 | Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
| 1239 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 1240 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 1241 | Supply & fixing clay tiles of 10X16 inches on roof including the cost of Ridge, typical caly tile, edge tiles and inlcusion of glass tiles in color and finish as per drawing approved from Architect in charge, and supply of all materials labours & tools etc required for safe erection and cost of adhesive, waterproof membrane and MS frame of L profile/rectangular hollow sections required for fixing and supprting the tiles., also includes the cost of all the necessary fitting and required for completion of the work as per Engineer in charge. |
| 1242 | INTERNAL W/S AND SANITATION (02 Nos) |
| 1243 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 1244 | W.C. pan with ISI marked white solid plastic seat and lid |
| 1245 | Providing and fixing white vitreous chinaextended wall mounting type water closet of size 780x370x690 mm of approved shape including providing & fixing white viterous china cistern with dual flush fittings of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litres ) includung seat cover & cistern fittings nuts , bolts and gaskets etc complete. |
| 1246 | Providing & fixing toilet paper holder |
| 1247 | C.P. brass |
| 1248 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 1249 | Providing and fixing Jaquar Make Hand Shower (Health Faucet) with 8mm Dia,1.2 Meter Long Flexible Tube & Wall Hook of quality and make as approved by Engineer - in - charge. |
| 1250 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 1251 | White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap |
| 1252 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- |
| 1253 | (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 1254 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 1255 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 1256 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 1257 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 1258 | Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern & jet) |
| 1259 | 15 mm nominal bore |
| 1260 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 1261 | 45 cm length |
| 1262 | 15 mm nominal bore |
| 1263 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
| 1264 | 100 mm diameter |
| 1265 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 1266 | 15 mm nominal bore |
| 1267 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. |
| 1268 | 15 mm nominal dia |
| 1269 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 1270 | 600 mm long towel rail with total length of 645 mm, width78 mm and effective height of 88 mm, weighing not lessthan 190 gms. |
| 1271 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 1272 | Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever required |
| 1273 | Kitchen sink with drain board |
| 1274 | 510x1040 mm bowl depth 200 mm |
| 1275 | Kitchen sink without drain board |
| 1276 | 610x510 mm bowl depth 200 mm |
| 1277 | Providing & fixing PVC waste pipe for sink including PVC waste fittings Complete |
| 1278 | Flexible Pipe |
| 1279 | 32mm Dia |
| 1280 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 1281 | 15mm nominal bore |
| 1282 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 1283 | 15mm nominal bore |
| 1284 | Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. |
| 1285 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (Including C.I. trap for standard urinal with vent arm with operating and other couplings in C.P.brass: 50 mm dia) |
| 1286 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as perdirection of Engineer-in-charge and finished smooth. |
| 1287 | Granite Stone of approved shade |
| 1288 | Providing and fixing of Kent Elite Plus Water Purifier (RO+UV+UF+TDS Control) with flow rate (50L/hr)including all its accessories, complete in all respect including testing etc. |
| 1289 | Providing and fixing of Water Cooler (Voltas Make) including all its accessories, complete in all respect including testing etc. |
| 1290 | Providing and fixing of storage type (pressurised type) electrichot water heater copper sheet container, 25 mm thickinsulation, stove enamelled M.S. jacket thermostatically controlled immersion heater with pilot neon lamp, suitable length of electrical cable and 15 amp 3 pin plug top, complete in all respect including testing etc. |
| 1291 | Capacity 25 Liters |
| 1292 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 1293 | Concealed work, including cutting chases and making good the walls etc. |
| 1294 | For Internal Toilet |
| 1295 | 15 mm nominal outer dia Pipes |
| 1296 | 20 mm nominal outer dia Pipes |
| 1297 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 1298 | Internal work - Exposed on wall |
| 1299 | 20 mm nominal bore |
| 1300 | 25 mm nominal bore |
| 1301 | 32 mm nominal bore |
| 1302 | 40 mm nominal bore |
| 1303 | Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall |
| 1304 | Terrace loop & Tank Filling Pipe |
| 1305 | 20 mm nominal bore |
| 1306 | 25 mm nominal bore |
| 1307 | 32 mm nominal bore |
| 1308 | 40 mm nominal bore |
| 1309 | 50 mm nominal bore |
| 1310 | 65 mm nominal bore |
| 1311 | 80 mm nominal bore |
| 1312 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : |
| 1313 | 20mm diameter pipe |
| 1314 | 25mm diameter pipe |
| 1315 | 32mm diameter pipe |
| 1316 | 40mm diameter pipe |
| 1317 | 50mm diameter pipe |
| 1318 | 65mm diameter pipe |
| 1319 | 80mm diameter pipe |
| 1320 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : |
| 1321 | 20mm diameter pipe |
| 1322 | 25mm diameter pipe |
| 1323 | 32mm diameter pipe |
| 1324 | 40mm diameter pipe |
| 1325 | 50mm diameter pipe |
| 1326 | 65mm diameter pipe |
| 1327 | 80mm diameter pipe |
| 1328 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 1329 | For vertical pipe connection with terrace ringmain |
| 1330 | 20 mm nominal bore |
| 1331 | 25mm nominal bore |
| 1332 | 32mm nominal bore |
| 1333 | 40mm nominal bore |
| 1334 | 50mm nominal bore |
| 1335 | 65mm nominal bore |
| 1336 | 80mm nominal bore |
| 1337 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 1338 | 25 to 40 mm nominal bore |
| 1339 | 50 to 80 mm nominal bore |
| 1340 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./H.P.H.D. plastic ball. |
| 1341 | 15 mm nominal bore, 105 mm long, weighing not less than 138 gms |
| 1342 | 20 mm nominal bore, 120 mm long, weighing not less than 198 gms |
| 1343 | 25 mm nominal bore, 152 mm long, weighing not less than 440 gms |
| 1344 | 40 mm nominal bore, 206 mm long, weighing not less than 690 gms |
| 1345 | 50 mm nominal bore, 242 mm long, weighing not less than 1240 gms |
| 1346 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 1347 | Providing, Fixing, Testing & Commissioning of XLPE Insulation of 9mm thickness on hot water supply pipes. Astral orequivalent approved complete in all respect as directed by Engineer-in-charge. |
| 1348 | 15mm dia (9 mm thickness) |
| 1349 | 20mm dia (9 mm thickness) |
| 1350 | 25mm dia (9 mm thickness) |
| 1351 | 32mm dia (9 mm thickness) |
| 1352 | 40mm dia (9 mm thickness) |
| 1353 | 50mm dia (9 mm thickness) |
| 1354 | Supply, fixing, testing and commissioning of following Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve - IP65CB - 230VAC, as per specifications:- |
| 1355 | Lehry Make Automatic OHT Level Control System Consist of Following Items |
| 1356 | 1) LEHRY Make On-Off Type Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve with CI Body & SS Disc 2) Level Float Switch- 5M 3) Control Box (a) IP 65 Finishing(250 x 160 x 115)mm (b) LED Lamps: Tank FULL, Tank EMPTY, Power (c) Power supply toggle switch (d) Accepts 230V Single Phase power supply and provides 24VAC to float switch and 230VAC to valve coil. (e) Accepts NO/NC feedback from float switch. |
| 1357 | 40mm |
| 1358 | 50mm |
| 1359 | 65mm |
| 1360 | 80mm |
| 1361 | Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mmof suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks. |
| 1362 | 25mm dia. |
| 1363 | 32mm dia. |
| 1364 | 40mm dia. |
| 1365 | 50mm dia. |
| 1366 | 65mm dia. |
| 1367 | 80mm dia. |
| 1368 | 100mm dia. |
| 1369 | 150mm dia. |
| 1370 | 200mm dia. |
| 1371 | 250mm dia. |
| 1372 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 1373 | 110 mm dia (for rain water) |
| 1374 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion. |
| 1375 | Single Push Fit Coupler |
| 1376 | 110 mm dia |
| 1377 | Single tee with door |
| 1378 | 110x110x110 mm |
| 1379 | Plain bend 87.5 deg |
| 1380 | 110 mm dia |
| 1381 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 1382 | 110 mm dia |
| 1383 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 1384 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. |
| 1385 | All kind of soil |
| 1386 | Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. |
| 1387 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: |
| 1388 | 100mm dia SWpipe |
| 1389 | Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. |
| 1390 | Internal Toilet (Soil & Waste Pipe) |
| 1391 | 75 mm |
| 1392 | 110 mm |
| 1393 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. |
| 1394 | Bend without door (45°) |
| 1395 | 75mm |
| 1396 | 110mm |
| 1397 | Bend without door (87.5°) |
| 1398 | 75mm bend |
| 1399 | 110mm |
| 1400 | Y\" Fitting without door |
| 1401 | 75mm |
| 1402 | 110mm |
| 1403 | Single Tee without door |
| 1404 | 75mm |
| 1405 | 110 mm |
| 1406 | Single Tee with door |
| 1407 | 75mm |
| 1408 | 110 mm |
| 1409 | Bend with door (87.5°) |
| 1410 | 75mm |
| 1411 | 110 mm |
| 1412 | Clean Out Plug (COP) |
| 1413 | 75mm |
| 1414 | 110 mm |
| 1415 | Reduced \"Y\" Fitting without door |
| 1416 | 110mm x 75mm |
| 1417 | Reduced Tee with door |
| 1418 | 110mm x 75mm |
| 1419 | Coupler |
| 1420 | 75mm |
| 1421 | 110mm |
| 1422 | Vent Cowl |
| 1423 | 110mm |
| 1424 | Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. |
| 1425 | For Wash basin & Urinal |
| 1426 | 32mm dia. Pipe |
| 1427 | Elbow (45°) |
| 1428 | 32mm |
| 1429 | Elbow (90°) |
| 1430 | 32mm |
| 1431 | T fitting |
| 1432 | 32mm |
| 1433 | 50mm |
| 1434 | Coupler |
| 1435 | 32mm |
| 1436 | Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. |
| 1437 | 110mm x 75mm x 50mm/40mm (Toilet) |
| 1438 | Providing, fixing, jointing and testing , ofPVC NahaniTrap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. |
| 1439 | 110mm x 75mm (Toilet & Kitchen) |
| 1440 | Providing and fixing PTMT grating of approved quality and colour. |
| 1441 | Rectangular type with openable circular lid |
| 1442 | 150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony) |
| 1443 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : |
| 1444 | 150 x 100mm size P-type |
| 1445 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 1446 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: |
| 1447 | 100 mm diameter |
| 1448 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. |
| 1449 | All kind of soil |
| 1450 | Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. |
| 1451 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: |
| 1452 | 100mm dia SWpipe |
| 1453 | INTERNAL ELECTRIFICATION WORK |
| 1454 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 1455 | Group - C |
| 1456 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 1457 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 1458 | Group -A |
| 1459 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 1460 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 1461 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 1462 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 1463 | 2 X 6 sq. mm + 1 X 4 sq. mm earth wire |
| 1464 | 2 x 10 sq.mm + 1 x 6sq.mm. earth wire |
| 1465 | 2 x 16 sq.mm + 1 x 6sq.mm. earth wire |
| 1466 | 4 x 6 sq.mm + 2 x 6 sq.mm. earth wire |
| 1467 | 4 x 10 sq.mm + 2 x 6 sq.mm. earth wire |
| 1468 | 4 x 16 sq.mm + 2 x 6sq.mm. earth wire |
| 1469 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 1470 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 1471 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 1472 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 1473 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 1474 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 1475 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 1476 | 5/6 A switch |
| 1477 | 3 pin 5/6 A socket outlet |
| 1478 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 1479 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 1480 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 1481 | Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 1482 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required |
| 1483 | Upto 450 mm sweep |
| 1484 | Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. |
| 1485 | Supply of Recessed mounting 2x2 feet 36W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. |
| 1486 | Supply of Recess mounting 2x2 feet 24 to 30W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. |
| 1487 | Supply of LED 4ft 40W LED Tube light with a nominal system lumen output of 4000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 3000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 42W (including driver). |
| 1488 | Supply of Suspended mounting 36W LED Liner Batten Light, suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. |
| 1489 | Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 21W (including driver). |
| 1490 | Supply of Surface mounting round 6 Watt 10 Watt , LED Down Lighter, suitable for 24Hr Continuous Operation, 660-1100 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. |
| 1491 | Supply of Recess mounting round 12 Watt 15 Watt ,suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect |
| 1492 | Supply of Suspended/Surface mounting round 12 Watt 15 Watt Light,suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect |
| 1493 | Supply of Recess mounting square 20 Watt , suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. |
| 1494 | Supplying of Bead Head light 31W fitting complete including connections etc. |
| 1495 | Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.complete in all respect |
| 1496 | Supplying of LED mirror light luminaire with 10Wwatt complete with electronic ballast, lamp including connection etc. complete as required. |
| 1497 | Supply of LED Flood light 50 Watt , suitable for 24Hr Continuous Operation, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, CCT 3000K, complete in all respect, |
| 1498 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 1499 | Supplying of 9 Watt 4 Star LED Wall Light Blub complete in all respect. |
| 1500 | Supplying of 9 Watt Decorative LED Wall Light complete in all respect. |
| 1501 | Supplying of 15 Watt decorative IP 66 LED UP-down Luminaire with wallsurface mounting using COB LED as light source. complete in all respect. |
| 1502 | Supplying of 7 Watt Step Light complete in all respect. |
| 1503 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan |
| 1504 | Supplying, erection, connecting, testing and commissioning of 400 mm Wall Fancomplete in all respect. |
| 1505 | Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required. |
| 1506 | 300mm EXHAUST FAN |
| 1507 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required |
| 1508 | 40 A,25KA,FP MCCB |
| 1509 | 63 A,25KA,FP MCCB |
| 1510 | 100 A,30KA,FPMCCB |
| 1511 | 125 A,36KA,FPMCCB |
| 1512 | 160 A,25KA,FP MCCB |
| 1513 | 200 A, 36KA,FPMCCB |
| 1514 | 250 A, 36KA,FPMCCB |
| 1515 | 320 A, 36KA,FPMCCB |
| 1516 | Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 1517 | 6 Way Double Door |
| 1518 | 8 way, Double door |
| 1519 | 12 way, Double Door |
| 1520 | 16 way, Double Door |
| 1521 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 1522 | 4 Way Double door |
| 1523 | 6 way Double door |
| 1524 | 8 way Double door |
| 1525 | 12 way Double door |
| 1526 | Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.) |
| 1527 | 4 way (4 + 12), Double door |
| 1528 | 8 way (4 + 24), Double door |
| 1529 | Supplying and fixing TP/FP sheet steel enclosure on surface/ recess. Suitable for upto 125 A 415 V MCCB complete with connections, testing and commissioning etc. as required. |
| 1530 | Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 1531 | 40 amps SP MCB |
| 1532 | 40 amps DP MCB |
| 1533 | 63 amps DP MCB |
| 1534 | 40 amps TP MCB |
| 1535 | 63 amps TP MCB |
| 1536 | 40 amps 4P MCB |
| 1537 | 63 amps 4P MCB |
| 1538 | 100 amps 4P MCB |
| 1539 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 1540 | 40 amps |
| 1541 | 63 amps |
| 1542 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 1543 | 40 amps |
| 1544 | 63 amps |
| 1545 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required. |
| 1546 | 25 amps |
| 1547 | 40 amps |
| 1548 | 63 amps |
| 1549 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 1550 | Single pole |
| 1551 | Double pole |
| 1552 | Triple pole |
| 1553 | Triple pole and neutral |
| 1554 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 1555 | Supplying and fixing 1P LCD Energy Meter 5-30A with BOX |
| 1556 | Supplying and fixing 3Ph 4 W kWh Dir base mtg 240V 10- 60 A Energy Meter |
| 1557 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 1558 | Supplying and fixing DP sheet steel enclosure on surface/ recessalong with 25/32 A 240 V \"C\" curve DP MCB complete withconnections, testing and commissioning etc. as required. |
| 1559 | Supplying and fixing 4P sheet steel enclosure on surface/ recess complete with connections, testing and commissioning etc. as required. |
| 1560 | Supplying and fixing TP/FP sheet steel enclosure on surface/ recess. Suitable for upto 125 A 415 V MCCB complete with connections, testing and commissioning etc. as required. |
| 1561 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 1562 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 1563 | SUBHEAD: - IV - MV PANEL |
| 1564 | Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.0mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCB\"s to be used.All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports. |
| 1565 | The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. |
| 1566 | The minimum clearances between bus bars shall be as follows : |
| 1567 | Phase to phase - minimum 20mm |
| 1568 | Phase to neutral-minimum 15mm |
| 1569 | Main LT Panel |
| 1570 | Incoming : |
| 1571 | 1 No 630 Amp. 4P MCCB of 35KA (Ics=Icu)Breaking Capacity |
| 1572 | 1 No 500 Amp. 4P MCCB of 35KA (Ics=Icu)Breaking Capacity |
| 1573 | 2 No 630 Amp. 4P CONTRACTOR |
| 1574 | Metering : |
| 1575 | 2 Set of CT\"s one of 630/ 5Amp ratio for Multifunction Meter |
| 1576 | 2 Set of CT\"s one of 630/ 5Amp ratio 27,47,59,81. |
| 1577 | 2 Set of CT\"s one of 200/ 5Amp ratio for APFC relay. |
| 1578 | 2 Set of Phase Indication Lamp. |
| 1579 | Bus Coupler : |
| 1580 | 1 No 630 Amp. 4P MCCB of 35KA (Ics=Icu)Breaking Capacity |
| 1581 | 1 No 630 Amp. 4P CONTRACTOR |
| 1582 | Bus Bar : |
| 1583 | 2 No. 800 Amp. FP aluminimum bus bar of suitable length. |
| 1584 | Outgoing : |
| 1585 | Phase indication lamps on each outgoing to be provided. |
| 1586 | 400 Amps FP MCCB of 35KA - 1 No |
| 1587 | 320 Amps FP MCCB of 35KA - 2 No |
| 1588 | 200 Amps FP MCCB of 35KA - 1 No |
| 1589 | 125 Amps FP MCCB of 35KA - 4 No |
| 1590 | 100 Amps FP MCCB of 35KA - 2 No |
| 1591 | 63 Amps FP MCCB of 35KA - 4 No |
| 1592 | 2 No. SPACE & SPARE |
| 1593 | Panel described as above |
| 1594 | CAPACITOR PANEL-100 KVAR |
| 1595 | SITC APFC Panel of 100 KVAR capacity suitable for operation on 415 + 5% Volt, 3 Phase, 50Hz, AC supply, having MPP type, resin bounded, static5,10,15,25 KVAR capacitors (without oil) in tier formationcomplete with following TPN MCCBas incomer of the panel, 11 step microprocessor based power factor controller relay capable to select the rating from 1 KVAR to multiples thereon up to max rating of the panel, current limiting contactors for each capacitors protected with MCBs, Ammeter (Analogue type) with CTs, Voltmeter (Analogue type) selector switches indicating lights, cooling fans for panel, earthing the panel with 2 Nos. 25mm x 5mm thick GI steel flat from existing earth bar, connection of APFC panel with suitable size 3.5 core aluminium conductor armoured XLPE cable from main LT panel (maximum length of cable 10 mtrs.) and compression glands etc. as reqd. The panel should have provision of timer based circuit in APFC relay to switch ON and OFF the static part automatically as and when requried. Capacity of Static capacitors should be accommodated from the overall rating of the panel and should be designed to switch in |
| 1596 | independently. The panel should be manufactured with 1.6mm thick CRCA sheet duly powder coated. |
| 1597 | Incoming |
| 1598 | One (1) No 200 Amp. 4P MCCB of 25 KABreaking capacity |
| 1599 | BUS BAR |
| 1600 | 1 Set of 300 Amps TPN Aluminium Bus Bars |
| 1601 | OUT GOING |
| 1602 | 02 No. 63 Amps. TP MCCB (25 KA)-25 KVAR |
| 1603 | 01 No. 40 Amps. TP MCCB (25 KA)-15 KVAR |
| 1604 | 03 No. 32 Amps. TP MCCB (25 KA)- 10 KVAR |
| 1605 | 01 No. 25 Amps. TP MCCB (25 KA)- 5 KVAR |
| 1606 | Panel described as above |
| 1607 | STREET LIGHT PANEL (OUTDOOR TYPE) IP 65 |
| 1608 | Incoming : |
| 1609 | One (1) No 63 Amp. 4P MCCB of 25KABreaking capacity |
| 1610 | Metering : |
| 1611 | One (1) No. SetsMultifunction Meter each incoming |
| 1612 | One (1) No. of Phase Indication Lamp each incoming |
| 1613 | Bus Bar : |
| 1614 | One (1) No. 80 Amp.TPN aluminimum bus bar of suitable length. |
| 1615 | Outgoing : |
| 1616 | Phase indication lamps on each outgoing to be provided. |
| 1617 | 2 No. 32 Amp 4PMCB. (10 KA) |
| 1618 | 20 No. 16 Amp DPMCB. (10 KA) |
| 1619 | 2 No. SPACE & SPARE |
| 1620 | Panel described as above |
| 1621 | Power Panel-LHS |
| 1622 | Incoming : |
| 1623 | 1 No 250 Amp. 4P MCCB of 25KABreaking capacity |
| 1624 | Metering : |
| 1625 | 1 Set of CT\"s one of 250/ 5Amp ratio for Multifunction Meter |
| 1626 | One (1) Set of Phase Indication Lamp. |
| 1627 | Bus Bar : |
| 1628 | 1 No. 300 Amp.TPN aluminimum bus bar of suitable length. |
| 1629 | Outgoing : |
| 1630 | Phase indication lamps on each outgoing to be provided. |
| 1631 | 3 No. 63 Amp 4PMCB |
| 1632 | 6 No. 40 Amp 4PMCB |
| 1633 | SPARE & SPACE- 2 No |
| 1634 | Panel described as above |
| 1635 | Power Panel-RHS |
| 1636 | Incoming : |
| 1637 | 1 No 320 Amp. 4P MCCB of 35KABreaking capacity |
| 1638 | Metering : |
| 1639 | 1 Set of CT\"s one of 320/ 5Amp ratio for Multifunction Meter |
| 1640 | One (1) Set of Phase Indication Lamp. |
| 1641 | Bus Bar : |
| 1642 | 1 No. 400 Amp.TPN aluminimum bus bar of suitable length. |
| 1643 | Outgoing : |
| 1644 | Phase indication lamps on each outgoing to be provided. |
| 1645 | 4 No. 100 Amp 4PMCB |
| 1646 | 3 No. 63 Amp 4PMCB |
| 1647 | 3 No. 40 Amp 4PMCB |
| 1648 | SPARE & SPACE- 2 No |
| 1649 | Panel described as above |
| 1650 | Light Panel-LHS |
| 1651 | Incoming : |
| 1652 | 1 No 200 Amp. 4P MCCB of 25KABreaking capacity |
| 1653 | Metering : |
| 1654 | 1 Set of CT\"s one of 200/ 5Amp ratio for Multifunction Meter |
| 1655 | One (1) Set of Phase Indication Lamp. |
| 1656 | Bus Bar : |
| 1657 | 1 No. 250 Amp.TPN aluminimum bus bar of suitable length. |
| 1658 | Outgoing : |
| 1659 | Phase indication lamps on each outgoing to be provided. |
| 1660 | 2 No. 63 Amp 4PMCB |
| 1661 | 7 No. 40 Amp 4PMCB |
| 1662 | SPARE & SPACE- 2 No |
| 1663 | Panel described as above |
| 1664 | Light Panel-RHS |
| 1665 | Incoming : |
| 1666 | 1 No 160 Amp. 4P MCCB of 25KABreaking capacity |
| 1667 | Metering : |
| 1668 | 1 Set of CT\"s one of 160/ 5Amp ratio for Multifunction Meter |
| 1669 | One (1) Set of Phase Indication Lamp. |
| 1670 | Bus Bar : |
| 1671 | 1 No. 200 Amp.TPN aluminimum bus bar of suitable length. |
| 1672 | Outgoing : |
| 1673 | Phase indication lamps on each outgoing to be provided. |
| 1674 | 1 No. 63 Amp 4PMCB |
| 1675 | 8 No. 40 Amp 4PMCB |
| 1676 | SPARE & SPACE- 2 No |
| 1677 | Panel described as above |
| 1678 | UPS PANEL |
| 1679 | Incoming : |
| 1680 | 2 No 125 Amp. 4P MCCB of 25KABreaking capacity |
| 1681 | Metering : |
| 1682 | 2 Set of CT\"s one of 125/ 5Amp ratio for Multifunction Meter |
| 1683 | 2 Set of Phase Indication Lamp. |
| 1684 | Bus Bar : |
| 1685 | One (1) No. 160 Amp.TPN aluminimum bus bar of suitable length. |
| 1686 | Outgoing : |
| 1687 | Phase indication lamps on each outgoing to be provided. |
| 1688 | 2 No. 63 Amp 4PMCB |
| 1689 | 8 No. 40 Amp 4PMCB |
| 1690 | 2 No. 40 Amp DPMCB |
| 1691 | SPARE & SPACE- 2 No |
| 1692 | Panel described as above |
| 1693 | ELEVATOR PANEL 1&2 |
| 1694 | Incoming : |
| 1695 | One (1) No 125 Amp. 4P MCCB of 25KABreaking capacity |
| 1696 | Metering : |
| 1697 | 1 Set of CT\"s one of 125/ 5Amp ratio for Multifunction Meter |
| 1698 | 1 Set of Phase Indication Lamp. |
| 1699 | Bus Bar : |
| 1700 | One (1) No. 200 Amp.TPN aluminimum bus bar of suitable length. |
| 1701 | Outgoing : |
| 1702 | Phase indication lamps on each outgoing to be provided. |
| 1703 | 3 No.63 Amp 4PMCCB. (25 KA) |
| 1704 | 3 No. 40 Amp DPMCB. (10 KA) |
| 1705 | SPARE & SPACE |
| 1706 | Panel described as above |
| 1707 | ELEVATOR PANEL 3 |
| 1708 | Incoming : |
| 1709 | One (1) No 80 Amp. 4P MCCB of 25KABreaking capacity |
| 1710 | Metering : |
| 1711 | 1 Set of CT\"s one of 80/ 5Amp ratio for Multifunction Meter |
| 1712 | 1 Set of Phase Indication Lamp. |
| 1713 | Bus Bar : |
| 1714 | One (1) No. 100 Amp.TPN aluminimum bus bar of suitable length. |
| 1715 | Outgoing : |
| 1716 | Phase indication lamps on each outgoing to be provided. |
| 1717 | 2 No.63 Amp 4PMCCB. (25 KA) |
| 1718 | 2 No.40 Amp DPMCB. (10 KA) |
| 1719 | SPARE & SPACE |
| 1720 | Panel described as above |
| 1721 | SUBHEAD: - V - EARTHING |
| 1722 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each |
| 1723 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 1724 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required |
| 1725 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 1726 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 1727 | Providing and laying earth connection from earth electrodewith 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earthelectrode including connection with G.I. thimble excavation andre-filling as required. |
| 1728 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 1729 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 1730 | Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes: |
| 1731 | 2 Pair (4 core) |
| 1732 | Providing, laying, connecting and testing of multi-core telephone armoured cable of conductor size 0.5mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable along wall or ceiling or through existing pipe. |
| 1733 | 100 Pair telephone cable |
| 1734 | 50 Pair telephone cable |
| 1735 | 20 Pair telephone cable |
| 1736 | 10 Pair telephone cable |
| 1737 | 5 Pair telephone cable |
| 1738 | Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted. |
| 1739 | 5 Pair tag block |
| 1740 | 10 pair tag block |
| 1741 | 20 pair tag block |
| 1742 | 50 pair tag block |
| 1743 | 100 pair tag block |
| 1744 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 1745 | 20mm dia PVC conduit |
| 1746 | 25mm dia PVC conduit |
| 1747 | 32mm dia PVC conduit |
| 1748 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required |
| 1749 | 1 or 2 Module (75mmX75mm) |
| 1750 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 1751 | Telephone socket outlet |
| 1752 | TV antenna socket outlet |
| 1753 | Bell Push |
| 1754 | RJ-45 Data Socket outlet |
| 1755 | Supplying and fixing call bell/ buzzer suitable for single phase,230 V, complete as required. |
| 1756 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 1757 | 1 run of cable |
| 1758 | Providing, laying, connecting and testing of unarmoured TV cable RG-6 PVC insulated cable along wall or ceiling or through existing pipe. |
| 1759 | Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 1760 | Up to 35 sq.mm. |
| 1761 | Above 35 sq.mm. and up to 95 sq.mm. |
| 1762 | Above 95 sq.mm. and upto 185 sq.mm. |
| 1763 | Above 185 sq.mm. and up to 400 sq.mm. |
| 1764 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, rotective covering and refilling the trench etc as required |
| 1765 | Up to 35 sq.mm. |
| 1766 | Above 35 sq.mm. and up to 95 sq.mm. |
| 1767 | Above 95 sq.mm. and upto 185 sq.mm. |
| 1768 | Above 185 sq.mm. and up to 400 sq.mm. |
| 1769 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 1770 | Up to 35 sq.mm. |
| 1771 | Above 35 sq.mm. and up to 95 sq.mm. |
| 1772 | Above 95 sq.mm. and upto 185 sq.mm. |
| 1773 | Above 185 sq.mm. and up to 400 sq.mm. |
| 1774 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 1775 | Up to 35 sq.mm. |
| 1776 | Above 35 sq.mm. and up to 95 sq.mm. |
| 1777 | Above 95 sq.mm. and upto 185 sq.mm. |
| 1778 | Above 185 sq.mm. and up to 400 sq.mm. |
| 1779 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required |
| 1780 | Up to 35 sq.mm. |
| 1781 | Above 35 sq.mm. and up to 95 sq.mm. |
| 1782 | Above 95 sq.mm. and upto 185 sq.mm. |
| 1783 | Above 185 sq.mm. and up to 400 sq.mm. |
| 1784 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required |
| 1785 | Upto 35 sq. mm (clamped with 1mm thick saddle |
| 1786 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp |
| 1787 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp |
| 1788 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 1789 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. |
| 1790 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 1791 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 1792 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 1793 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 1794 | Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment |
| 1795 | 3.5 x 400 sq.mm. |
| 1796 | 3.5 x 300 sq.mm. |
| 1797 | 3.5 x 240 sq.mm. |
| 1798 | 3.5 x 185 sq.mm |
| 1799 | 3.5 x 150 sq.mm |
| 1800 | 3.5 x 120 sq.mm |
| 1801 | 3.5 x 95 sq.mm |
| 1802 | 3.5 x 70 sq.mm |
| 1803 | 3.5 x 50 sq.mm |
| 1804 | 3.5 x 35 sq.mm |
| 1805 | 3.5 x 25 sq.mm. |
| 1806 | 4 x 25 sq.mm |
| 1807 | 4 x 16 sq.mm |
| 1808 | 4 x 10 sq.mm |
| 1809 | 4 x 6 sq.mm |
| 1810 | 3 x 6 sq.mm |
| 1811 | 2 x 16 sq.mm, |
| 1812 | 2 x 10 sq.mm, |
| 1813 | 2 x 6 sq.mm, |
| 1814 | Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. |
| 1815 | 2 X 6 sq. mm (19mm) |
| 1816 | 2 X 10 sq. mm (19mm) |
| 1817 | 2 X 16 sq. mm (22mm) |
| 1818 | 3½ X 25 sq. mm (28mm) |
| 1819 | 3½ X 35 sq. mm (32mm) |
| 1820 | 3½ X 50 sq. mm (35mm) |
| 1821 | 3½ X 70 sq. mm (38mm) |
| 1822 | 3½ X 95 sq. mm (45mm) |
| 1823 | 3½ X 120 sq. mm (45mm) |
| 1824 | 3½ X 150 sq. mm (50mm) |
| 1825 | 3½ X 185 sq. mm (57mm) |
| 1826 | 3½ X 225 sq. mm (62mm) |
| 1827 | 3½ X 240 sq. mm (62mm) |
| 1828 | 3½ X 300 sq. mm (70mm) |
| 1829 | 3½ X 400 sq. mm (82mm) |
| 1830 | 4 X 10 sq. mm (25mm) |
| 1831 | 4 X 16 sq. mm (28mm) |
| 1832 | Providing, laying and fixing following dia G.I. pipe (mediumclass) in ground complete with G.I. fittings including trenching(75 cm deep)and re-filling etc as required |
| 1833 | 100 mm dia |
| 1834 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. |
| 1835 | 100mm dia |
| 1836 | 150 mm dia |
| 1837 | 250 mm dia |
| 1838 | 300 mm dia |
| 1839 | Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioningand protective covering etc., complete as required. |
| 1840 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 1841 | Site Development Works |
| 1842 | Internal Pathways: Providing and fixing of exposed brickwork in Flooring (407.94 Sqm) |
| 1843 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. (DSR 2.8.1) |
| 1844 | UNDER EDGE SIDE |
| 1845 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. (DSR 4.1.8) |
| 1846 | UNDER EDGE SIDE |
| 1847 | UNDER PATHWAY |
| 1848 | M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 1849 | Providing and fixing exposed brick flooring with modular common burnt clay bricks, machine made bricks: Indian chamfered and classic belgian rough bricks where edges are sharp and borders are straight and Size of200X100X40 for belgian rough and 230X110X25 for Indian chamfered having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%on a bed of 12 mm cement mortar, to be laid in pattern as per drawing approved from Architect in charge including filling the joints with same mortar (make Prayag Clay Products or equivalent) |
| 1850 | AR Pathway |
| 1851 | External Water Supply , Drain, Tubewell & RWH |
| 1852 | SEWERAGE & WATER SUPPLY SYSTEM |
| 1853 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. |
| 1854 | up to 1.50 m depth |
| 1855 | Pipes 80 mm to 300 mmdiameter |
| 1856 | 1.50 m to 3.00 m depth |
| 1857 | Pipes 80 mm to 300 mmdiameter |
| 1858 | Opentimbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) |
| 1859 | Depth not exceeding 1.5 meter |
| 1860 | Depth 1.5 to3.00meter |
| 1861 | Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. |
| 1862 | 150 mm.dia. RCCPipes |
| 1863 | 250 mm.dia. RCCPipes |
| 1864 | 300 mm.dia. RCCPipes |
| 1865 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design |
| 1866 | 150 mm.dia. RCCPipes |
| 1867 | 250 mm.dia. RCCPipes |
| 1868 | 300 mm.dia. RCCPipes |
| 1869 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. |
| 1870 | Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). |
| 1871 | With common burnt clay FPS (non modular) bricks of class designation 75 |
| 1872 | (i) For Sewer Line |
| 1873 | Extra for depth for manholes: |
| 1874 | Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 |
| 1875 | Inside size 90x120cms and 90cms deep including CI cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg). |
| 1876 | With common burnt clay FPS (non modular) bricks of class designation 75 |
| 1877 | (i) For Sewer Line |
| 1878 | Extra for depth for manholes: |
| 1879 | Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 |
| 1880 | Providing orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 1881 | Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. (external work) |
| 1882 | 80mm nominal bore. |
| 1883 | 65mm nominal bore. |
| 1884 | 50mm nominal bore. |
| 1885 | 40mm nominal bore. |
| 1886 | 32mm nominal bore. |
| 1887 | 25mm nominal bore. |
| 1888 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 1889 | 80mm nominal bore. |
| 1890 | 65mm nominal bore. |
| 1891 | 50mm nominal bore. |
| 1892 | 40mm nominal bore. |
| 1893 | 32mm nominal bore. |
| 1894 | 25mm nominal bore. |
| 1895 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : (horizontal) |
| 1896 | 80mm nominal bore. |
| 1897 | 65mm nominal bore. |
| 1898 | 50mm nominal bore. |
| 1899 | 40mm nominal bore. |
| 1900 | 32mm nominal bore. |
| 1901 | 25mm nominal bore. |
| 1902 | Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design : |
| 1903 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 1904 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick,finished with a floating coat of neat cement complete as per standard design : |
| 1905 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 1906 | RAIN WATER HARVESTING & DRAINAGE SYSTEM |
| 1907 | RECHARGE PITS |
| 1908 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge. |
| 1909 | In all kind of soil upto 1.5m depth |
| 1910 | In all kind of soil upto 1.5m to 3.0m. depth |
| 1911 | In all kind of soil upto 3.0m to 4.5m. depth |
| 1912 | In all kind of soil upto 4.5 m to 6.0m. depth |
| 1913 | Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. |
| 1914 | Class M-150 brick work in 1:4 cement coarse sand mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. |
| 1915 | Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. |
| 1916 | Suspended floors, roofs, landings, balconies and access platform. |
| 1917 | Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 1918 | 12mm cement plaster on rough side of single or half brick wall mix |
| 1919 | 1:3 (1 cement : 3 Coarse sand) |
| 1920 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: |
| 1921 | With 20x20mm square bar |
| 1922 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 1923 | M.D. -10- Circular shape 500mm internal diameter |
| 1924 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. |
| 1925 | Drilling of 300mm dia bore hole manually. |
| 1926 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
| 1927 | 150 mm nominal size dia |
| 1928 | Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for all leads& lifts, all complete as per direction of Engineer-in-charge. |
| 1929 | Supplying, filling, spreading & leveling gravels of size range 5 mm to10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge. |
| 1930 | Supplying, filling, spreading & leveling coarse sand of size range 1.5mm to 2 mm in recharge pit, in required thickness over gravel layer,for all leads & lifts, all complete as per direction of Engineer -incharge. |
| 1931 | Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading& sizes as per actual requirement, all complete as per direction ofEngineer-in-charge. |
| 1932 | DESILTING CHAMBER |
| 1933 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge. |
| 1934 | In all kind of soil upto 1.5m depth |
| 1935 | In all kind of soil upto 1.5m to 3.0m. depth |
| 1936 | Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. |
| 1937 | Class M-150 brick work in 1:4 cement coarse sand mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. |
| 1938 | Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. |
| 1939 | Suspended floors, roofs, landings, balconies and access platform. |
| 1940 | Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 1941 | 15mm cement plaster on rough side of single or half brick wall mix |
| 1942 | 1:3 (1 cement : 3 Coarse sand) |
| 1943 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: |
| 1944 | With 20x20mm square bar |
| 1945 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 1946 | M.D. -10- Circular shape 500mm internal diameter |
| 1947 | DRAINAGE NETWORK |
| 1948 | Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. |
| 1949 | up to 1.50 m depth |
| 1950 | Pipes 80 mm to 300 mmdiameter |
| 1951 | Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. |
| 1952 | 150 mm.dia. RCCPipes |
| 1953 | 250 mm.dia. RCCPipes |
| 1954 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design |
| 1955 | 150 mm. dia. |
| 1956 | 250 mm. dia. |
| 1957 | Constructing brick masonry INSPECTION chamber 60x60x75 cm with bricks of class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as perdesign. With FPS bricks |
| 1958 | Constructing brick masonary open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design: |
| 1959 | Drain 300 wide average.Depth 45 cm with R.C.C. slab |
| 1960 | Drain 450 wide average.Depth 60 cm with R.C.C. slab |
| 1961 | EXTERNAL SEWERAGE SYSTEM (SEPTIC TANK) |
| 1962 | Size :- Length = 7.50 M. Width = 2.65M Total Depth =3.00M |
| 1963 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge. |
| 1964 | In all kind of soil upto 1.5m depth |
| 1965 | In all kind of soil upto 1.5m to 3.0m. depth |
| 1966 | In all kind of soil upto 3.0m to 4.5m. depth |
| 1967 | Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size) |
| 1968 | Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) |
| 1969 | Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. |
| 1970 | Suspended floors, roofs, landings, balconies and access platform. |
| 1971 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 1972 | 12mm cement plaster on rough side of mix 1:3 (1 cement : 3 coarse sand) |
| 1973 | Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. |
| 1974 | Providing and fixing C.I. tee at the inlet and outlet of septic tank. |
| 1975 | Providing & fixing 75mm dia vent pipes. |
| 1976 | Providing & fixing of 75mm dia cast iron terminal guard. |
| 1977 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 1978 | M.D. -10- Circular shape 500mm internal diameter |
| 1979 | M.D. -2.5- Circular shape 450mm internal diameter |
| 1980 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. |
| 1981 | With F.P.S. bricks |
| 1982 | TUBE WELL |
| 1983 | Drilling of 200 mm dia bore hole. |
| 1984 | Supply of 125 mm dia MSpipe as per IS1239 |
| 1985 | Supply of 125 mm dia slotted MSpipe |
| 1986 | Supply and fixing of nylon jali around the slotted pipes complete as required. |
| 1987 | Providing and packing of coarse sand / pea gravel around the pipe. |
| 1988 | Transport of boring tools other required equipements and installation at site. |
| 1989 | Supply of submersible pump (3.7KW/5.0 HP) of make KSB (Cora) for 200 lit/min discharge at 50 meter head with control panel, support wire etc complete. |
| 1990 | Providing 3 core PVC insulated submersible cable. (from pump panel to submersible pump) |
| 1991 | Providing and fixing 65 mm dia. G.I. pipe complete with fittings and clamps including cutting and making good the wall etc. (from submersible pump to ground level) |
| 1992 | Providing and fixing 65 mm dia. brass gate valve with CI wheel of approved quality. |
| 1993 | Lowering of 125 mm dia MS pipe in bore hole including cutting,jointing etc complete. |
| 1994 | Supply and fixing of tube well accessories i.e. well cap, clips, clamps, etc. to complete the job in all respect. |
| 1995 | Fixing, testing and commissioning for erection and lowering of submersible pump, 65 mm dia GI column pipe, 3 core submersible copper cable upto the control panel, supporting clamps, cable clips, pressure gauge, connection line and all other accessories required for the proper completion of the work. |
| 1996 | Testing and development of tube well. |
| 1997 | Horticulture and Landscape |
| 1998 | Supplying and stacking sludge at site including royalty and carriage up to 1 km (sludge measured in stacks will be reduced by 8% for payment). |
| 1999 | Carrigae of sludge upto 5 K.M. |
| 2000 | Supplying and stacking at site dump manure from approved source including carriage upto 1 km (manure measured instacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm |
| 2001 | Carrigae of manure upto 5 K.M. |
| 2002 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge. |
| 2003 | Spreading of sludge, dump manure or/and good earth in requiredthickness (cost of sludge dump manure or/and good earth to bepaid separately). |
| 2004 | Digging holes in ordinary soil and refilling the same with theexcavated earth mixed with manure or sludge in the ratio of 2:1by volume (2 parts of stacked volume of earth after reduction by20% : 1 part of stacked volume of manure after reduction by 8%), flooding with water, dressing, including removal of rubbish and surplus earth, if any with all leads and lifts ( cost of manure, sludge or extra good earth if needed to be paid for separately). |
| 2005 | Holes 0.9 m dia. and 0.90 m deep. |
| 2006 | Providing & stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge. |
| 2007 | Providing & stacking of Pinus longifolia (Pinus) of height 90-105 cm. in cement pots of size 35cm as per direction of the officer-in-charge. |
| 2008 | Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately). With grass Turf. |
| 2009 | Providing and fixing M.S. flat iron tree guard 60 cm dia and 2 m high, above ground consisting 4 nos 25 x 6 mm, 2.25 m long and 8 nos 25 x 3 mm 2 m long verticals M.S. flats, riveted to 3 nos 25 x 6 mm M.S. flat iron rings in two halves, fixing together at site with required six numbers of 8 mm dia. and 30 mm long bolts, including painting two coats with synthetic enamel paint of approved brand and manufacture over a coat of primer. One name plate of 1 mm thick M.S. sheet of size 250x100 mm shall be welded to the treeguard near the middle height and lettered CPWD / PWD/ any other approved name. The tree guard shall be suitably fixed to the ground by embedding four legs of tree guard in pits of suitable dia and to a depth of 25 cm, refilling the pits with soil and ramming, complete in all respect as per satisfaction and direction of Officer-in-charge. |
| 2010 | Add for Ornamental trees, shrubs & planters |
| 2011 | PVC Coatd Fencing |
| 2012 | Fencing Rear Side (Details as per TS estimate) |
| 2013 | Fencing Left/Right Side (Details as per TS estimate) |
| 2014 | Development of Front Boundary Wall (AR- BW1) (55.07 RM) |
| 2015 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. |
| 2016 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-lll) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 2017 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) [ M-20 ] |
| 2018 | All works upto plinth level |
| 2019 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 2020 | All works Above plinth level |
| 2021 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 2022 | Foundations, footings, bases of columns, etc. for mass concrete |
| 2023 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 2024 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 2025 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. |
| 2026 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 2027 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 2028 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand |
| 2029 | Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 2030 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 2031 | Providing, Suppling & fixing of cultural Terracotta tile mural work of 20mm thick inspired from the extraction of Ramayana and the Local Tangible context as per architect incharge. |
| 2032 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 2033 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 2034 | Parking |
| 2035 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. (DSR 2.8.1) |
| 2036 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. (DSR 4.1.8) |
| 2037 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.. (DSR 2.27) |
| 2038 | M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work.(DSR 6.1.2) |
| 2039 | 15mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand of 2.25 F.M. (DSR 13.5.1) |
| 2040 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr10 sqm (DSR 13.48.1) |
| 2041 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete (DSR 13.80) |
| 2042 | Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on# 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick Jamunasand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge.[DSR 11.45] |
| 2043 | Providing & fixing White/Colored River (Stone) Pebbles size of 1\" to 2\" dia in natural colour at site of work including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge. (Details as per TS Estimate) |
| 2044 | Entrance Gate |
| 2045 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 2046 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 2047 | Signages |
| 2048 | A. THEMED INTERIOR & ART WORKS |
| 2049 | Wall Panelling: Fabricating & fixing full height plywood panelling (overall thickness 62mm) consisting of 50mm x 25mm x 2mm GI sections approved Make framework with all necessary reinforcements required of GI, at spacing not exceeding 600mm x 1200 . Partition framework to be fixed to existing masonry walls. Rate to include providing and fixing of additional GI sections of approved size as per Architects drawings. Cost to include additional sections (horizontal & Vertical) as required for fixing of Digital Displays, Screens.,, Glass boards, and White boards as indicated by the Architect. Cost to also include the necessary provisions required to take Data & Electrical conduiting. |
| 2050 | Boarding: Boarding with 12mm th Fire resistant pre laminated LDF Board LDF board |
| 2051 | Cost to include an average projection of 600mm from true wall including creating slopes, curves in elevations as indicated in the drawings. |
| 2052 | Cost to include providing of recess of upto 200 mm such as coves and niches, the shape shall be not measured seperately |
| 2053 | Cost to include providing necessary BWP plywood backing up to 18mm for Digital displays as indicated in the drawing |
| 2054 | Cost will be measured based on the board up area and not for frame works. |
| 2055 | Approved Brands - 1. Frame : Jindal, apollo, sections or equivalent2. Plywood - Green ply, Kitply, Merino, archidply or equivalent3. Laminate– Merino, Greenlam or equivalent |
| 2056 | RAISED PLATFORMProviding and fabricating 225mm Low Raised Platform made of GI/MS framework using 50mm x 50mm GI/MS sections Jindal Make framework with all necessary reinforcements required of MS/GI, at spacing not exceeding 600mm both ways ( horizontal & vertical ). Framework to be fixed to existing surface. Boarding made of 18mm BWP plywood fixed to MS/GI frame, including required joints & surface finish as indicated in the architect drawing. Cost to also include the necessary provisions required to take Data & Electrical conduiting. |
| 2057 | GRAPHIC/CONTENT SIGNAGE BOARDVinyl print with Installation - Providing & Fixing Printed Vinyl Graphics on Punned or Levelled Surface of (3M or Equivalent) ,overPlywood /MDF or Laminate. Cost to include cleaningfor any stains, scffolding for height upto 8000mm from FFL as per design approved by ARchitect in chargeApproved Make - 3M, LG, Avery/Equivalent |
| 2058 | Infographics design for the above vinyl prints:Design and development of all the infographics as per the museum design in Hindi & English languages make approved s per drawings directed as per Architect in-charge. 2D Illustration& Artwork & Interactive,MotionGraphics, 2DAnimations,Editing&Compositing, scripted with poetic flair and historic accuracy providingthegreatestcinematicexperience. Use of animated layers composited with archives, animated text, illustration, complementing the masking narration, ambience and music. Producing graphical contentofvernacularpressforinteractive LEDs. Producing well styled, contemporary themed,graphicalcontentwithexhaustive coverageofthe Mainpuri city\"s culturefor12 interactivescreensandaninteractivetable with10Mwidescreensoneachsides.All content to becompletein allaspects,as per design approved by Architect in charge |
| 2059 | B. AV WORKS |
| 2060 | PC for Interactive Kiosks Intel I5 PC/ 16GB Ram/ 512 GB SSD/ DvdR/ P4000 8Gb Gfx/ Win 10 ProApproved Makes: Dell/HP/Lenovo/Equivalent as approved by ARchitect in charge |
| 2061 | 32\" Interactive display Approved Makes: LG/Panasonic/Samsung/Benq/Veiwsonic/Equivalent |
| 2062 | HDMI Over Cat6/FOTransmitterUp to 2560x1600* @ 60 Hz or 4K (4096x2160) @ 30 Hz, UHD (3840x2160) @ 30 Hz, 4K/UHD @ 60 Hz with 4:2:0 chroma subsampling, HDMI 1.4, HDCP 2.3, Max Vide Data Rate 10.2 Gbps, support pixel clock of 300Mhz, accepts addition stereo audio, RS232, IR Signals.Approved Makes: Extron/Crestron/Lightware/Aten/Equivalent as approved by ARchitect in charge |
| 2063 | SITC of necessary track lights/Spot liighting for all the infographics artefacts/ manuscript display Case, as per design. as approved by ARchitect in charge |
| 2064 | Resting Areas for Tourist (Benches) {MR} |
| 2065 | Providing & fixing ofred Sandstone/MS bench with Ornamentetion on armrest (size 1050mm length and 450mm and height 450 mm) including foundation & support with all necessary T&P etc all complete as per design of direction in engineer/ Architect in charge. |
| 2066 | Urban Litter Bins(MR) |
| 2067 | Providing & fixing of SS Dustbin size 487 x 399 x 1138 fixing on a foundation with base plate and wrapped with red sandstone from all sides of 75mm with all complete as per design of direction in engineer/ Architect in charge. |
| 2068 | Directional & Informative Signages (MR) |
| 2069 | Providing and fixing StandAlone Signage in Metal/stone/Corten steel of approved thickness with powder coated 10-12mm MS letters and illustration at desired locations with letters (in english, hindi and Braille)- etched, through cut, infilled or painted, also including the cost of design, fabrication and onsite installation with all the necessary accessories and equipments for fixing on any surface as per drawing and design approved from Architect in charge English: Helvetica Font with min. 36 size Hindi: Krutidev Fontwith min. 36 size |
| 2070 | Signage-A |
| 2071 | Signage-B |
| 2072 | Signage-C |
| 2073 | External Electrification |
| 2074 | Supplying, Installation and commissioning of AMF start silent type62.5 KVA DG set comprising of suitable BHPdiesel engine directly coupledto 3 phase 50 Hz 415 V alternator of 160 KVA rating at 0.8 power factor mounted on a common base frame, complete in all respects with all required safety devices, fittings, batteries, accessories, filters, residential type silencer, control panel, inbuilt diesel oil MS tank of 990 ltrs. capacity made of 2mm thick M.S. sheet complete with M.S. fuel piping, G.M. gate valves, supports, control cable between generating set and control panel, exhaust piping with asbestos roping, antivibration mounting pads, first filling of lubricant oil totally enclosed in air tight, dust proof, weather proof, powder coated cubical type, sound proof as per CPCB norms acoustic enclosure made of 2mm thick CRCA sheet with with heavy duty doors, lockable arrangement, sound proof insulation with high density rock/mineral polymer/fibre cloth and perforated CRCA sheets, suitable to reduce the sound level upto 75dba approx. at a distance of 1 mtrs. as per CPCB norms |
| 2075 | AMF Panel Incoming-160 Amps FP MCCB of 36KA breaking capacity and contactor same rating |
| 2076 | Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB\"s (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only. |
| 2077 | MAIN FEEDER PANEL |
| 2078 | Incoming : |
| 2079 | 2 No 160 Amp. 4P MCCB of 25KA (Ics=Icu)Breaking Capacity |
| 2080 | Metering : |
| 2081 | 2 Set of CT\"s one of 160/ 5Amp ratio for Multifunction Meter |
| 2082 | 2 Set of Phase Indication Lamp. |
| 2083 | Bus Bar : |
| 2084 | One (1) No. 200 Amp. FP aluminimum bus bar of suitable length. |
| 2085 | Outgoing : |
| 2086 | Phase indication lamps on each outgoing to be provided. |
| 2087 | 100 Amps FP MCB - 2 No |
| 2088 | 63 Amps FP MCB - 2 No |
| 2089 | 25 Amps DP MCB - 3 No |
| 2090 | 16 Amps DP MCB - 6 No |
| 2091 | SPARE & SPACE- 1 No |
| 2092 | Panel described as above |
| 2093 | FEEDER PILLAR |
| 2094 | 1 No 63 Amp. 4P MCCB of 25KA (Ics=Icu)Breaking Capacity |
| 2095 | Metering : |
| 2096 | 1 Set of Phase Indication Lamp. |
| 2097 | Bus Bar : |
| 2098 | One (1) No. 100 Amp. FP aluminimum bus bar of suitable length. |
| 2099 | Outgoing : |
| 2100 | Phase indication lamps on each outgoing to be provided. |
| 2101 | 40 Amps DP MCB - 3 No |
| 2102 | 25 Amps DP MCB - 1 No |
| 2103 | 16 Amps DP MCB - 8 No |
| 2104 | SPARE & SPACE- 1 No |
| 2105 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each |
| 2106 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required |
| 2107 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 2108 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required |
| 2109 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 2110 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 2111 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 2112 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 2113 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 2114 | Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 2115 | Up to 35 sq.mm. |
| 2116 | Above 35 sq.mm. and up to 95 sq.mm. |
| 2117 | Above 95 sq.mm. and upto 185 sq.mm. |
| 2118 | Above 185 sq.mm. and up to 400 sq.mm. |
| 2119 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, rotective covering and refilling the trench etc as required |
| 2120 | Up to 35 sq.mm. |
| 2121 | Above 35 sq.mm. and up to 95 sq.mm. |
| 2122 | Above 95 sq.mm. and upto 185 sq.mm. |
| 2123 | Above 185 sq.mm. and up to 400 sq.mm. |
| 2124 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 2125 | Up to 35 sq.mm. |
| 2126 | Above 35 sq.mm. and up to 95 sq.mm. |
| 2127 | Above 95 sq.mm. and upto 185 sq.mm. |
| 2128 | Above 185 sq.mm. and up to 400 sq.mm. |
| 2129 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 2130 | Up to 35 sq.mm. |
| 2131 | Above 35 sq.mm. and up to 95 sq.mm. |
| 2132 | Above 95 sq.mm. and upto 185 sq.mm. |
| 2133 | Above 185 sq.mm. and up to 400 sq.mm. |
| 2134 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required |
| 2135 | Up to 35 sq.mm. |
| 2136 | Above 35 sq.mm. and up to 95 sq.mm. |
| 2137 | Above 95 sq.mm. and upto 185 sq.mm. |
| 2138 | Above 185 sq.mm. and up to 400 sq.mm. |
| 2139 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required |
| 2140 | Upto 35 sq. mm (clamped with 1mm thick saddle |
| 2141 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp |
| 2142 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp |
| 2143 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 2144 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. |
| 2145 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 2146 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 2147 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 2148 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 2149 | Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment |
| 2150 | 3.5 x 400 sq.mm. |
| 2151 | 3.5 x 300 sq.mm. |
| 2152 | 3.5 x 240 sq.mm. |
| 2153 | 3.5 x 185 sq.mm |
| 2154 | 3.5 x 150 sq.mm |
| 2155 | 3.5 x 120 sq.mm |
| 2156 | 3.5 x 95 sq.mm |
| 2157 | 3.5 x 70 sq.mm |
| 2158 | 3.5 x 50 sq.mm |
| 2159 | 3.5 x 35 sq.mm |
| 2160 | 3.5 x 25 sq.mm. |
| 2161 | 4 x 16 sq.mm |
| 2162 | 4 x 10 sq.mm |
| 2163 | 3 x 6 sq.mm, |
| 2164 | 2 x 16 sq.mm, |
| 2165 | 2 x 10 sq.mm, |
| 2166 | 2 x 6 sq.mm, |
| 2167 | Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. |
| 2168 | 2 X 6 sq. mm (19mm) |
| 2169 | 2 X 10 sq. mm (19mm) |
| 2170 | 2 X 16 sq. mm (22mm) |
| 2171 | 3½ X 25 sq. mm (28mm) |
| 2172 | 3½ X 35 sq. mm (32mm) |
| 2173 | 3½ X 50 sq. mm (35mm) |
| 2174 | 3½ X 70 sq. mm (38mm) |
| 2175 | 3½ X 95 sq. mm (45mm) |
| 2176 | 3½ X 120 sq. mm (45mm) |
| 2177 | 3½ X 150 sq. mm (50mm) |
| 2178 | 3½ X 185 sq. mm (57mm) |
| 2179 | 3½ X 225 sq. mm (62mm) |
| 2180 | 3½ X 240 sq. mm (62mm) |
| 2181 | 3½ X 300 sq. mm (70mm) |
| 2182 | 3½ X 400 sq. mm (82mm) |
| 2183 | 4 X 10 sq. mm (25mm) |
| 2184 | 4 X 16 sq. mm (28mm) |
| 2185 | Providing, laying and fixing following dia G.I. pipe (mediumclass) in ground complete with G.I. fittings including trenching(75 cm deep)and re-filling etc as required |
| 2186 | 100 mm dia |
| 2187 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. |
| 2188 | 100mm dia |
| 2189 | 150 mm dia |
| 2190 | 250 mm dia |
| 2191 | 300 mm dia |
| 2192 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 2193 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 2194 | ProvidingandfixingHT danger notice plate 250 mm x 200 mm made of mild steel at least 2mmthick &vitreousenamelledwhiteon bothsides and withinscription insignalred colouronfront side as required. |
| 2195 | Supplying andFixing of Fire buckets, round bottom made of G.I. Sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-charge. |
| 2196 | Supplying and Laying of Rubber mat 1000 mm. Wide to withstand 11 KV dielectric strength as per latest IS 15652-2006 etc. as reqd. |
| 2197 | Supply and fixing of fire extinguishers, ABC Type 9.00 kg. capacity(ISI Marked IS : 15683 & TAC approved)complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 2198 | Supply and fixing of CO2 typefire extinguishers, 4.50 kg. capacity(ISI Marked IS : 2878 & TAC approved)complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 2199 | Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : |
| 2200 | With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 |
| 2201 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 2202 | Double pole |
| 2203 | S & F cast Step light complete as required. Step Light31435, Anthracite grey, Aluminium, 104x104x35,LED Integrated3W, 50lm/3000K, Make Philips or Equivalent |
| 2204 | S & F Spike light complete as required. |
| 2205 | S & F cast aluminium 4 mtr. Pole for post top light complete as required Town Glow Post Top Town Glow is a contemporary designer IP66/IK10 Post Top lantern with symmetric light distribution BGP300 LED40 757 PSU PC IN SI hsn code 9405 make Philips or euqivalent |
| 2206 | Supply and fixingUNILinear Flex is IP68 cove lighting with reliable performance and excellently waterproof, anti-dust LED strips with professional design for vivid colors.BGC301 400LM 3000K L5000 9405 |
| 2207 | Supply and fixing of decorative 8 to 16 Watt LED bollard luminaire with driver set confirming to IP 65 protection complete in all respect |
| 2208 | Supply and fixing of LED Gate light fitting having die cast aluminium body and diffuser with driver set suitable for 6 watt to 10 watt. Confirming to IP 54 and above protection complete in all respect. |
| 2209 | Supply and fixing Superior illumination Classy anthracite finishPremium aluminium material Optimum performanceHighlight the outdoors IP65 fixture ideal for outdoor & wet areasupdown lighterModel No.-31450Colour-AnthraciteMaterial-AluminiumDimensions (mm)-159x99x66Lamp Base-LED IntegratedWattage-10WLumen/CCT-670lm/3000KMAKE -PHILIPS or equivelant |
| 2210 | Supply and fixingUNIIn-Ground: Ground BurialCompact and robust design with diecast aluminium housingand stainless trim, IP68 waterproof connectors.11:50 BBP341 LED540/WW 6W 20D 100-240VMAKE -PHILIPS or equivelant |
| 2211 | SITC of 15w integrated Solar All in one suitable at height of 5mtr mounting arrangement. pole with minimum 2250 lumen , luminous flux with min.>150lm/w luminous efficacy having power of PV module (Wp) 40, Panel Type Mono Crystalline, Panel Dimensions not more than (mm) 775 (L) x 340 (W) x 60 (H), Battery Capacity max. 18 (Ah), Battery Rated Voltage 12.8(V), Battery type LiFePO4, having BMS protection Battery Management System ,having min. Battery Back up to 2days (24 hours) (Autonomy mode),MPPT charge controller type, Efficacy>90%, having facility of Charging Indicator (Green blinking),Low Battery Indicator (Red blinking),Error Indicator (Both blinking),For the better battery life having Over Charge Protection, Deep Discharge Protection, Battery reverse polarity protection ,Load Short circuit protection, Load Open circuit protection, Reverse polarity protection for Panel, Over temperature protection. Motion sensor detection facility with Long Distance Detection 12m.CCT-5500-6000k, Make-Panasonic, Philips or equivalent |
| 2212 | Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. |
| 2213 | 1 output per phase and suitable for single phase supply |
| 2214 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. |
| 2215 | Above 6.5 metre and upto 8.0 metre |
| 2216 | Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required |
| 2217 | 32 mm dia |
| 2218 | GST Extra As per Applicable |
AI Tender Summary
Tender Timeline
Jun 27, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedJul 04, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJul 04, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer