Housing Urban and Rular Development Government Departments Closing in 0 days TDR #43919317

Tender For Development Of Tourism Amenities At Sohagi Barwa Wildlife Sanctuary, Maharajganj

Issued by Government Departments · mahrajganj, Uttar Pradesh
Tender Value
3.70 Crore
Estimated cost
Bid Submission
04 Jul 2024
0 days left
EMD
7.40 Lakhs
Bank guarantee accepted
Document Fee
17700
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
mahrajganj → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Development Of Tourism Amenities At Sohagi Barwa Wildlife Sanctuary, Maharajganj

BOQ

Name of Work: Development of Tourism Amenities at Sohagi Barwa Wildlife Sanctuary, Maharajganj
Sl. No. Item Description
1ADMIN BLOCK,CAFETERIA & INTERPRETATION AREA (Civil)
2Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
3Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
4Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-lll) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
5Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete..
6Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion)
7Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
8Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2(1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
9Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level
10Concrete of M-25 grade with minimum cement content of 330 kg /cum
11Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V level
12Concrete of M25 grade with minimum cement content of 330 kg /cum
13M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work.
14Providing and laying damp-proof course 25 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size).
15Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
16Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)
17Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)
18Providing machine made Wire Cut Bricks where edges are sharp and borders are straight and Size of8.5\"x 4\"x3\"having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%. Thickness of 230mm wall
19Providing and fixing exposed brick flooring with modular common burnt clay bricks, machine made bricks: Indian chamfered and classic belgian rough bricks where edges are sharp and borders are straight and Size of200X100X40 for belgian rough and 230X110X25 for Indian chamfered having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%on a bed of 12 mm cement mortar, to be laid in pattern as per drawing approved from Architect in charge including filling the joints with same mortar (make Prayag Clay Products or equivalent)
20Supply and Laying a water soluble penetrative solution for waterproofing of masonry building material & Nano technology based as it provides molecular level hydrophobicity to inorganic substrate .The product is based on organosilicon chemistry, hence reacts with the inorganic substrate surface, seals the surface uto a depth of 2-3 mm and provides long service life where Nano size allows penetration deep into substrate that provides 20+ years water repellency.(Zycosil/Pratt & Lamber or Equivalent) including cost of all materials, labour tools and plants etc. required for proper completion of the work.
21P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. (TMT Fe-500)
2215 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 coarse sand)
2315 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand
2412mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarsesand.
2512mm thick plaster in 1:3 on ceiling and soffitsof stairs upto floor two level.
26Forming groove of uniform size from 12x12 mm and upto 25x15 mm in the top layer of washed stone grit plastered surface as per approved pattern, including providing and fixing aluminum channels of appropriate size and thickness (not less than 2 mm), nailed to the under layer with rust proof screws and nails and finishing the groove complete as per specifications and direction of the Engineer-in-Charge
27Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to 1S:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily,Glazed Vitrified tiles Matt/Antiskid finish of size 600 x 600 mm
28Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
29Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade ofthe slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
30Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
31Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm. Granite stone slab of all colour and texture
32Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor).
33Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any Size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
34Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
35(a) Single leaf
36(b) Double leaf
37Both side laminated
38Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin- charge.Extruded section profile size 48x40 mm
39Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash andmullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.
40Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speeds Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.
41Using R4 series with frame (115 mm & above) x (45 mm & above) & both glazed and fly screen sash (44 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coatedhandle on every glazed panel along with multipoint locking system. (Height above 1.8m)
42Wall Painting with plastic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats (For Internal wall surface)
43Wall Painting with plastic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats (For Internal ceiling surface)
44Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
45Natural Mud plaster+ paint Aggregate made up of Lime, Clay & Additives in given proportion to get the desired Texture.Shade, Texture and number of coatsas per architects approval to get the desired finished
46Cost of Artistic Mural & painting as per Design received from Architect Incharge.
47Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to
48IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick
49jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
50Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete.
51Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm .
52Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete
53(a) 300 mm x 10mm
54(b) 200 x 10mm
55Providing and fixing stainless steel handles with screws etc. complete (a) 150 mm
56Float glass panes 4 mm thick glass pane (weight not less than 10 kg/sqm).
57Providing & Fixing of Aluminium window with 5 mm glass pans.
58Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge
59Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channelwith connecting clips made out of 2.64 mm dia x 230 mm long G.I.wire at every junction, including fixing perimeter channels 0.5 mm
60thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings,pecification and direction of the Engineer in Charge but excluding the cost of painting with :
6112.5 mm thick tapered edge gypsum moisture resistant board
62Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applyinga priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
63Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm overan under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
64Centering and shuttering including strutting, propping etc. and removal of form for:
65Foundations, footings, bases of columns, etc. for mass concrete
66Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
67Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick
68Columns, Pillars, Piers, Abutments, Posts and Struts
69INTERNAL W/S AND SANITATION
70Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
71W.C. pan with ISI marked white solid plastic seat and lid
72Providing and fixing white vitreous chinaextended wall mounting type water closet of size 780x370x690 mm of approved shape including providing & fixing white viterous china cistern with dual flush fittings of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litres ) includung seat cover & cistern fittings nuts , bolts and gaskets etc complete.
73Providing & fixing toilet paper holder
74C.P. brass
75Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
76Providing and fixing Jaquar Make Hand Shower (Health Faucet) with 8mm Dia,1.2 Meter Long Flexible Tube & Wall Hook of quality and make as approved by Engineer - in - charge.
77Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
78White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap
79Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-
80(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
81Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
82Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
83Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
84Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
85Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern & jet)
8615 mm nominal bore
87Providing and fixing uplasticised PVC connection pipe with brass unions :
8845 cm length
8915 mm nominal bore
90Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
91100 mm diameter
92Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
9315 mm nominal bore
94Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.
9515 mm nominal dia
96Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
97600 mm long towel rail with total length of 645 mm, width78 mm and effective height of 88 mm, weighing not lessthan 190 gms.
98Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
99Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever required
100Kitchen sink with drain board
101510x1040 mm bowl depth 200 mm
102Kitchen sink without drain board
103610x510 mm bowl depth 200 mm
104Providing & fixing PVC waste pipe for sink including PVC waste fittings Complete
105Flexible Pipe
10632mm Dia
107Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
10815mm nominal bore
109Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
11015mm nominal bore
111Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge.
112Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (Including C.I. trap for standard urinal with vent arm with operating and other couplings in C.P.brass: 50 mm dia)
113Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as perdirection of Engineer-in-charge and finished smooth.
114Granite Stone of approved shade
115Providing and fixing of Kent Elite Plus Water Purifier (RO+UV+UF+TDS Control) with flow rate (50L/hr)including all its accessories, complete in all respect including testing etc.
116Providing and fixing of Water Cooler (Voltas Make) including all its accessories, complete in all respect including testing etc.
117Providing and fixing of storage type (pressurised type) electrichot water heater copper sheet container, 25 mm thickinsulation, stove enamelled M.S. jacket thermostatically controlled immersion heater with pilot neon lamp, suitable length of electrical cable and 15 amp 3 pin plug top, complete in all respect including testing etc.
118Capacity 25 Liters
119Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
120Concealed work, including cutting chases and making good the walls etc.
121For Internal Toilet
12215 mm nominal outer dia Pipes
12320 mm nominal outer dia Pipes
12425 mm nominal outer dia Pipes
12532 mm nominal outer dia Pipes
126Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
127Internal work - Exposed on wall
12820 mm nominal bore
12925 mm nominal bore
13032 mm nominal bore
13140 mm nominal bore
132Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall
133Terrace loop & Tank Filling Pipe
13420 mm nominal bore
13525 mm nominal bore
13632 mm nominal bore
13740 mm nominal bore
13850 mm nominal bore
13965 mm nominal bore
14080 mm nominal bore
141Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :
14220mm diameter pipe
14325mm diameter pipe
14432mm diameter pipe
14540mm diameter pipe
14650mm diameter pipe
14765mm diameter pipe
14880mm diameter pipe
149Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :
15020mm diameter pipe
15125mm diameter pipe
15232mm diameter pipe
15340mm diameter pipe
15450mm diameter pipe
15565mm diameter pipe
15680mm diameter pipe
157Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
158For vertical pipe connection with terrace ringmain
15920 mm nominal bore
16025mm nominal bore
16132mm nominal bore
16240mm nominal bore
16350mm nominal bore
16465mm nominal bore
16580mm nominal bore
166Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
16725 to 40 mm nominal bore
16850 to 80 mm nominal bore
169Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./H.P.H.D. plastic ball.
17025 mm nominal bore, 152 mm long, weighing not less than 440 gms
17140 mm nominal bore, 206 mm long, weighing not less than 690 gms
17250 mm nominal bore, 242 mm long, weighing not less than 1240 gms
173Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
174Providing, Fixing, Testing & Commissioning of XLPE Insulation of 9mm thickness on hot water supply pipes. Astral orequivalent approved complete in all respect as directed by Engineer-in-charge.
17515mm dia (9 mm thickness)
17620mm dia (9 mm thickness)
17725mm dia (9 mm thickness)
17832mm dia (9 mm thickness)
17940mm dia (9 mm thickness)
18050mm dia (9 mm thickness)
181Supply, fixing, testing and commissioning of following Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve - IP65CB - 230VAC, as per specifications:-
182Lehry Make Automatic OHT Level Control System Consist of Following Items
1831) LEHRY Make On-Off Type Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve with CI Body & SS Disc 2) Level Float Switch- 5M 3) Control Box (a) IP 65 Finishing(250 x 160 x 115)mm (b) LED Lamps: Tank FULL, Tank EMPTY, Power (c) Power supply toggle switch (d) Accepts 230V Single Phase power supply and provides 24VAC to float switch and 230VAC to valve coil. (e) Accepts NO/NC feedback from float switch.
18440mm
18550mm
18665mm
18780mm
188Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mmof suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks.
18925mm dia.
19032mm dia.
19140mm dia.
19250mm dia.
19365mm dia.
19480mm dia.
195100mm dia.
196150mm dia.
197200mm dia.
198250mm dia.
199Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
200110 mm dia (for rain water)
201Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion.
202Single Push Fit Coupler
203110 mm dia
204Single tee with door
205110x110x110 mm
206Plain bend 87.5 deg
207110 mm dia
208Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
209110 mm dia
210Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
211Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.
212All kind of soil
213Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia.
214Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design:
215100mm dia SWpipe
216Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes.
217Internal Toilet (Soil & Waste Pipe)
21875 mm
219110 mm
220Exposed on Wall (Soil & Waste Pipe)
221110 mm
222Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.
223Bend without door (45°)
22475mm
225110mm
226Bend without door (87.5°)
22775mm bend
228110mm
229Y\" Fitting without door
23075mm
231110mm
232Single Tee without door
23375mm
234110 mm
235Single Tee with door
23675mm
237110 mm
238Bend with door (87.5°)
23975mm
240110 mm
241Clean Out Plug (COP)
24275mm
243110 mm
244Reduced \"Y\" Fitting without door
245110mm x 75mm
246Reduced Tee with door
247110mm x 75mm
248Coupler
24975mm
250110mm
251Vent Cowl
252110mm
253Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc.
254For Wash basin & Urinal
25532mm dia. Pipe
25650mm dia. pipe
257Elbow (45°)
25832mm
25950mm
260Elbow (90°)
26132mm
26250mm
263T fitting
26432mm
26550mm
266Coupler
26732mm
26850mm
269Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge.
270110mm x 75mm x 50mm/40mm (Toilet)
271Providing, fixing, jointing and testing , ofPVC NahaniTrap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge.
272110mm x 75mm (Toilet & Kitchen)
273Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap Adaptor (Height Riser), making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge.
274110mm x 50mm/40mm
275Providing and fixing PTMT grating of approved quality and colour.
276Rectangular type with openable circular lid
277150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony)
278Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
279150 x 100mm size P-type
280With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
281Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete:
282100 mm diameter
283Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.
284All kind of soil
285Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia.
286Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design:
287100mm dia SWpipe
288INTERNAL ELECTRIFICATION WORK
289Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
290Group - C
291Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
292Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required
293Group -A
294Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2952 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2962 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2972 X 4 sq. mm + 1 X 4 sq. mm earth wire
2982 X 6 sq. mm + 1 X 4 sq. mm earth wire
2992 x 10 sq.mm + 1 x 6sq.mm. earth wire
3002 x 16 sq.mm + 1 x 6sq.mm. earth wire
3014 x 6 sq.mm + 2 x 6 sq.mm. earth wire
3024 x 10 sq.mm + 2 x 6 sq.mm. earth wire
3034 x 16 sq.mm + 2 x 6sq.mm. earth wire
304Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required.
305Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
306Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
307Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required.
308Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
309Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required
310Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
3115/6 A switch
3123 pin 5/6 A socket outlet
313Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
314Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
315Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
316Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
317Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required
318Upto 450 mm sweep
319Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes.
320Supply of Recessed mounting 2x2 feet 36W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect.
321Supply of Recess mounting 2x2 feet 24 to 30W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect.
322Supply of LED 4ft 40W LED Tube light with a nominal system lumen output of 4000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 3000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 42W (including driver).
323Supply of Suspended mounting 36W LED Liner Batten Light, suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect.
324Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 21W (including driver).
325Supply of Recess mounting round 6 Watt 10 Watt , LED Down Lighter, suitable for 24Hr Continuous Operation, 660-1100 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect.
326Supply of Recess mounting round 12 Watt 15 Watt ,suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect
327Supply of Recess mounting square 20 Watt , suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect.
328Supplying of Bead Head light 31W fitting complete including connections etc.
329Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.complete in all respect
330Supplying of LED mirror light luminaire with 10Wwatt complete with electronic ballast, lamp including connection etc. complete as required.
331Supply of LED Flood light 50 Watt , suitable for 24Hr Continuous Operation, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, CCT 3000K, complete in all respect,
332Supplying and fixing brass batten/ angle holder including connection etc. as required.
333Supplying of 9 Watt 4 Star LED Wall Light Blub complete in all respect.
334Supplying of 9 Watt Decorative LED Wall Light complete in all respect.
335S & F cast Step light complete as required. Step Light31435, Anthracite grey, Aluminium, 104x104x35,LED Integrated3W, 50lm/3000K, Make Philips or Equivalent
336Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan
337Supplying, erection, connecting, testing and commissioning of 400 mm Wall Fancomplete in all respect.
338Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.
339300mm EXHAUST FAN
340Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required
34140 A,25KA,FP MCCB
34263 A,25KA,FP MCCB
343100 A,30KA,FPMCCB
344125 A,36KA,FPMCCB
345160 A,25KA,FP MCCB
346200 A, 36KA,FPMCCB
347250 A, 36KA,FPMCCB
348320 A, 36KA,FPMCCB
349Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
3506 Way Double Door
3518 way, Double door
35212 way, Double Door
35316 way, Double Door
354Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
3554 Way Double door
3566 way Double door
3578 way Double door
35812 way Double door
359Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.)
3604 way (4 + 12), Double door
3618 way (4 + 24), Double door
362Supplying and fixing TP/FP sheet steel enclosure on surface/ recess. Suitable for upto 125 A 415 V MCCB complete with connections, testing and commissioning etc. as required.
363Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required
36440 amps SP MCB
36540 amps DP MCB
36663 amps DP MCB
36740 amps TP MCB
36863 amps TP MCB
36940 amps 4P MCB
37063 amps 4P MCB
371100 amps 4P MCB
372Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required
37340 amps
37463 amps
375Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required
37640 amps
37763 amps
378Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required.
37925 amps
38040 amps
38163 amps
382Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
383Single pole
384Double pole
385Triple pole
386Triple pole and neutral
387Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
388Supplying and fixing 1P LCD Energy Meter 5-30A with BOX
389Supplying and fixing 3Ph 4 W kWh Dir base mtg 240V 10- 60 A Energy Meter
390Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
391Supplying and fixing DP sheet steel enclosure on surface/ recessalong with 25/32 A 240 V \"C\" curve DP MCB complete withconnections, testing and commissioning etc. as required.
392Supplying and fixing 4P sheet steel enclosure on surface/ recess complete with connections, testing and commissioning etc. as required.
393Supplying and fixing TP/FP sheet steel enclosure on surface/ recess. Suitable for upto 125 A 415 V MCCB complete with connections, testing and commissioning etc. as required.
394Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
39590 mm dia (OD-90 mm & ID-76 mm nominal)
396SUBHEAD: - IV - EARTHING
397Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each
398Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required.
399Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
400Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
401Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
402Providing and laying earth connection from earth electrodewith 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earthelectrode including connection with G.I. thimble excavation andre-filling as required.
403Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
404Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.
405Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes:
4062 Pair (4 core)
407Providing, laying, connecting and testing of multi-core telephone armoured cable of conductor size 0.5mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable along wall or ceiling or through existing pipe.
408100 Pair telephone cable
40950 Pair telephone cable
41020 Pair telephone cable
41110 Pair telephone cable
4125 Pair telephone cable
413Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted.
4145 Pair tag block
41510 pair tag block
41620 pair tag block
41750 pair tag block
418100 pair tag block
419Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
42020mm dia PVC conduit
42125mm dia PVC conduit
42232mm dia PVC conduit
423Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required
4241 or 2 Module (75mmX75mm)
425Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
426Telephone socket outlet
427TV antenna socket outlet
428Bell Push
429RJ-45 Data Socket outlet
430Supplying and fixing call bell/ buzzer suitable for single phase,230 V, complete as required.
431Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
4321 run of cable
433Providing, laying, connecting and testing of unarmoured TV cable RG-6 PVC insulated cable along wall or ceiling or through existing pipe.
434Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
435Up to 35 sq.mm.
436Above 35 sq.mm. and up to 95 sq.mm.
437Above 95 sq.mm. and upto 185 sq.mm.
438Above 185 sq.mm. and up to 400 sq.mm.
439Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, rotective covering and refilling the trench etc as required
440Up to 35 sq.mm.
441Above 35 sq.mm. and up to 95 sq.mm.
442Above 95 sq.mm. and upto 185 sq.mm.
443Above 185 sq.mm. and up to 400 sq.mm.
444Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
445Up to 35 sq.mm.
446Above 35 sq.mm. and up to 95 sq.mm.
447Above 95 sq.mm. and upto 185 sq.mm.
448Above 185 sq.mm. and up to 400 sq.mm.
449Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
450Up to 35 sq.mm.
451Above 35 sq.mm. and up to 95 sq.mm.
452Above 95 sq.mm. and upto 185 sq.mm.
453Above 185 sq.mm. and up to 400 sq.mm.
454Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required
455Up to 35 sq.mm.
456Above 35 sq.mm. and up to 95 sq.mm.
457Above 95 sq.mm. and upto 185 sq.mm.
458Above 185 sq.mm. and up to 400 sq.mm.
459Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required
460Upto 35 sq. mm (clamped with 1mm thick saddle
461Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp
462Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp
463Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
464Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
465Upto 35 sq. mm (clamped with 1mm thick saddle)
466Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
467Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
468Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
469Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment
4703.5 x 400 sq.mm.
4713.5 x 300 sq.mm.
4723.5 x 240 sq.mm.
4733.5 x 185 sq.mm
4743.5 x 150 sq.mm
4753.5 x 120 sq.mm
4763.5 x 95 sq.mm
4773.5 x 70 sq.mm
4783.5 x 50 sq.mm
4793.5 x 35 sq.mm
4803.5 x 25 sq.mm.
4814 x 25 sq.mm
4824 x 16 sq.mm
4834 x 10 sq.mm
4844 x 6 sq.mm
4852 x 16 sq.mm,
4862 x 10 sq.mm,
4872 x 6 sq.mm,
488Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.
4892 X 6 sq. mm (19mm)
4902 X 10 sq. mm (19mm)
4912 X 16 sq. mm (22mm)
4923½ X 25 sq. mm (28mm)
4933½ X 35 sq. mm (32mm)
4943½ X 50 sq. mm (35mm)
4953½ X 70 sq. mm (38mm)
4963½ X 95 sq. mm (45mm)
4973½ X 120 sq. mm (45mm)
4983½ X 150 sq. mm (50mm)
4993½ X 185 sq. mm (57mm)
5003½ X 225 sq. mm (62mm)
5013½ X 240 sq. mm (62mm)
5023½ X 300 sq. mm (70mm)
5033½ X 400 sq. mm (82mm)
5044 X 10 sq. mm (25mm)
5054 X 16 sq. mm (28mm)
506Providing, laying and fixing following dia G.I. pipe (mediumclass) in ground complete with G.I. fittings including trenching(75 cm deep)and re-filling etc as required
507100 mm dia
508Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
509100mm dia
510150 mm dia
511250 mm dia
512300 mm dia
513Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioningand protective covering etc., complete as required.
51490 mm dia (OD-90 mm & ID-76 mm nominal)
515Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
516100 mm wide x 50 mm depth x 1.6 mm thickness.
517150 mm wide x 50 mm depth x 1.6 mm thickness.
518300 mm wide x 50 mm depth x 1.6 mm thickness.
519Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \"bends\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
520100 mm wide x 50 mm depth x 1.6 mm thickness.
521ACCOMMODATION CATEGORY -I (EACH WITH 2 ROOMS) Civil (03 Nos)
522Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
523Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
524Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors.
525Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete..
526Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion)
527Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface ofthe substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete:With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
528Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
529Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) [ M-20 ]
530All works upto plinth level
531Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
532All works Above plinth level
533M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work.
534Providing and laying damp-proof course 25 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size).
535Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
536Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
537Cement mortar 1:6 (1 cement : 6 coarse sand)
538Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
539Cement mortar 1:4 (1 cement :4 coarse sand)
540Extra for forming cavity 5 cm to 11.5 cm wide in cavity walls with necessary weep and vent holes including use of cores and cost of providing and fixing bitumastic coated M .S. ties 300 mm long of 25x3 mm section at not less than 3 ties per sqm as per approved design.
541Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry.
542Providing machine made Wire Cut Bricks where edges are sharp and borders are straight and Size of8.5\"x 4\"x3\"having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%. Thickness of 230mm wall
543Supply and Laying a water soluble penetrative solution for waterproofing of masonry building material & Nano technology based as it provides molecular level hydrophobicity to inorganic substrate .The product is based on organosilicon chemistry, hence reacts with the inorganic substrate surface, seals the surface uto a depth of 2-3 mm and provides long service life where Nano size allows penetration deep into substrate that provides 20+ years water repellency.(Zycosil/Pratt & Lamber or Equivalent) including cost of all materials, labour tools and plants etc. required for proper completion of the work.
544P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. (TMT Fe-500)
54515mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand of 2.25 F.M.
54615 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand
54715 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand
54812mm thick plaster in 1:3 on ceiling and soffits of stairs upto floor two level.
549Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any Size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
550Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to 1S:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily,Glazed Vitrified tiles Matt/Antiskid finish of size 600 x 600 mm
551Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, inskirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
552Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm. Granite stone slab of all colour and texture
553Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor).
554Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
555(a) Single leaf
556(b) Double leaf
557Both side laminated
558Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin-charge.Extruded section profile size 48x40 mm
559Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash andmullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.
560Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speeds Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.
561Using R4 series with frame (115 mm & above) x (45 mm & above) & both glazed and fly screen sash (44 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coatedhandle on every glazed panel along with multipoint locking system. (Height above 1.8m)
562Wall Painting with plastic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats (For Internal wall surface)
563Wall Painting with plastic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats (For Internal ceiling surface)
564Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
565Natural Mud plaster+ paint Aggregate made up of Lime, Clay & Additives in given proportion to get the desired Texture.Shade, Texture and number of coatsas per architects approval to get the desired finished
566Cost of Artistic Mural & painting as per Design received from Architect Incharge.
567Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to
568IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick
569jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
570Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete.
571Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm .
572Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete
573(a) 300 mm x 10mm
574(b) 200 x 10mm
575Providing and fixing stainless steel handles with screws etc. complete (a) 150 mm
576Float glass panes 4 mm thick glass pane (weight not less than 10 kg/sqm).
577Centering and shuttering including strutting, propping etc. and removal of form for:
578Foundations, footings, bases of columns, etc. for mass concrete
579Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
580Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick
581Columns, Pillars, Piers, Abutments, Posts and Struts
582Supply & fixing clay tiles of 10X16 inches on roof including the cost of Ridge, typical caly tile, edge tiles and inlcusion of glass tiles in color and finish as per drawing approved from Architect in charge, and supply of all materials labours & tools etc required for safe erection and cost of adhesive, waterproof membrane and MS frame of L profile/rectangular hollow sections required for fixing and supprting the tiles., also includes the cost of all the necessary fitting and required for completion of the work as per Engineer in charge.
583INTERNAL W/S AND SANITATION (03 Nos)
584Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
585W.C. pan with ISI marked white solid plastic seat and lid
586Providing and fixing white vitreous chinaextended wall mounting type water closet of size 780x370x690 mm of approved shape including providing & fixing white viterous china cistern with dual flush fittings of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litres ) includung seat cover & cistern fittings nuts , bolts and gaskets etc complete.
587Providing & fixing toilet paper holder
588C.P. brass
589Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
590Providing and fixing Jaquar Make Hand Shower (Health Faucet) with 8mm Dia,1.2 Meter Long Flexible Tube & Wall Hook of quality and make as approved by Engineer - in - charge.
591Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
592White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap
593Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-
594(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
595Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
596Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
597Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
598Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
599Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern & jet)
60015 mm nominal bore
601Providing and fixing uplasticised PVC connection pipe with brass unions :
60245 cm length
60315 mm nominal bore
604Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
605100 mm diameter
606Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
60715 mm nominal bore
608Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.
60915 mm nominal dia
610Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
611600 mm long towel rail with total length of 645 mm, width78 mm and effective height of 88 mm, weighing not lessthan 190 gms.
612Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
613Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever required
614Kitchen sink with drain board
615510x1040 mm bowl depth 200 mm
616Kitchen sink without drain board
617610x510 mm bowl depth 200 mm
618Providing & fixing PVC waste pipe for sink including PVC waste fittings Complete
619Flexible Pipe
62032mm Dia
621Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
62215mm nominal bore
623Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
62415mm nominal bore
625Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge.
626Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (Including C.I. trap for standard urinal with vent arm with operating and other couplings in C.P.brass: 50 mm dia)
627Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as perdirection of Engineer-in-charge and finished smooth.
628Granite Stone of approved shade
629Providing and fixing of Kent Elite Plus Water Purifier (RO+UV+UF+TDS Control) with flow rate (50L/hr)including all its accessories, complete in all respect including testing etc.
630Providing and fixing of Water Cooler (Voltas Make) including all its accessories, complete in all respect including testing etc.
631Providing and fixing of storage type (pressurised type) electrichot water heater copper sheet container, 25 mm thickinsulation, stove enamelled M.S. jacket thermostatically controlled immersion heater with pilot neon lamp, suitable length of electrical cable and 15 amp 3 pin plug top, complete in all respect including testing etc.
632Capacity 25 Liters
633Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
634Concealed work, including cutting chases and making good the walls etc.
635For Internal Toilet
63615 mm nominal outer dia Pipes
63720 mm nominal outer dia Pipes
638Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
639Internal work - Exposed on wall
64020 mm nominal bore
64125 mm nominal bore
64232 mm nominal bore
64340 mm nominal bore
644Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall
645Terrace loop & Tank Filling Pipe
64620 mm nominal bore
64725 mm nominal bore
64832 mm nominal bore
64940 mm nominal bore
65050 mm nominal bore
65165 mm nominal bore
65280 mm nominal bore
653Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :
65420mm diameter pipe
65525mm diameter pipe
65632mm diameter pipe
65740mm diameter pipe
65850mm diameter pipe
65965mm diameter pipe
66080mm diameter pipe
661Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :
66220mm diameter pipe
66325mm diameter pipe
66432mm diameter pipe
66540mm diameter pipe
66650mm diameter pipe
66765mm diameter pipe
66880mm diameter pipe
669Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
670For vertical pipe connection with terrace ringmain
67120 mm nominal bore
67225mm nominal bore
67332mm nominal bore
67440mm nominal bore
67550mm nominal bore
67665mm nominal bore
67780mm nominal bore
678Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
67925 to 40 mm nominal bore
68050 to 80 mm nominal bore
681Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./H.P.H.D. plastic ball.
68215 mm nominal bore, 105 mm long, weighing not less than 138 gms
68320 mm nominal bore, 120 mm long, weighing not less than 198 gms
68425 mm nominal bore, 152 mm long, weighing not less than 440 gms
68540 mm nominal bore, 206 mm long, weighing not less than 690 gms
68650 mm nominal bore, 242 mm long, weighing not less than 1240 gms
687Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
688Providing, Fixing, Testing & Commissioning of XLPE Insulation of 9mm thickness on hot water supply pipes. Astral orequivalent approved complete in all respect as directed by Engineer-in-charge.
68915mm dia (9 mm thickness)
69020mm dia (9 mm thickness)
69125mm dia (9 mm thickness)
69232mm dia (9 mm thickness)
69340mm dia (9 mm thickness)
69450mm dia (9 mm thickness)
695Supply, fixing, testing and commissioning of following Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve - IP65CB - 230VAC, as per specifications:-
696Lehry Make Automatic OHT Level Control System Consist of Following Items
6971) LEHRY Make On-Off Type Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve with CI Body & SS Disc 2) Level Float Switch- 5M 3) Control Box (a) IP 65 Finishing(250 x 160 x 115)mm (b) LED Lamps: Tank FULL, Tank EMPTY, Power (c) Power supply toggle switch (d) Accepts 230V Single Phase power supply and provides 24VAC to float switch and 230VAC to valve coil. (e) Accepts NO/NC feedback from float switch.
69840mm
69950mm
70065mm
70180mm
702Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mmof suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks.
70325mm dia.
70432mm dia.
70540mm dia.
70650mm dia.
70765mm dia.
70880mm dia.
709100mm dia.
710150mm dia.
711200mm dia.
712250mm dia.
713Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
714110 mm dia (for rain water)
715Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion.
716Single Push Fit Coupler
717110 mm dia
718Single tee with door
719110x110x110 mm
720Plain bend 87.5 deg
721110 mm dia
722Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
723110 mm dia
724Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
725Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.
726All kind of soil
727Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia.
728Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design:
729100mm dia SWpipe
730Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes.
731Internal Toilet (Soil & Waste Pipe)
73275 mm
733110 mm
734Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.
735Bend without door (45°)
73675mm
737110mm
738Bend without door (87.5°)
73975mm bend
740110mm
741Y\" Fitting without door
74275mm
743110mm
744Single Tee without door
74575mm
746110 mm
747Single Tee with door
74875mm
749110 mm
750Bend with door (87.5°)
75175mm
752110 mm
753Clean Out Plug (COP)
75475mm
755110 mm
756Reduced \"Y\" Fitting without door
757110mm x 75mm
758Reduced Tee with door
759110mm x 75mm
760Coupler
76175mm
762110mm
763Vent Cowl
764110mm
765Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc.
766For Wash basin & Urinal
76732mm dia. Pipe
768Elbow (45°)
76932mm
770Elbow (90°)
77132mm
772T fitting
77332mm
77450mm
775Coupler
77632mm
777Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge.
778110mm x 75mm x 50mm/40mm (Toilet)
779Providing, fixing, jointing and testing , ofPVC NahaniTrap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge.
780110mm x 75mm (Toilet & Kitchen)
781Providing and fixing PTMT grating of approved quality and colour.
782Rectangular type with openable circular lid
783150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony)
784Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
785150 x 100mm size P-type
786With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
787Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete:
788100 mm diameter
789Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.
790All kind of soil
791Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia.
792Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design:
793100mm dia SWpipe
794INTERNAL ELECTRIFICATION WORK 03 Nos
795Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
796Group - C
797Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
798Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required
799Group -A
800Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
8012 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
8022 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
8032 X 4 sq. mm + 1 X 4 sq. mm earth wire
8042 X 6 sq. mm + 1 X 4 sq. mm earth wire
8052 x 10 sq.mm + 1 x 6sq.mm. earth wire
8062 x 16 sq.mm + 1 x 6sq.mm. earth wire
8074 x 6 sq.mm + 2 x 6 sq.mm. earth wire
8084 x 10 sq.mm + 2 x 6 sq.mm. earth wire
8094 x 16 sq.mm + 2 x 6sq.mm. earth wire
810Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required.
811Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
812Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
813Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required.
814Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
815Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required
816Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
8175/6 A switch
8183 pin 5/6 A socket outlet
819Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
820Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
821Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
822Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
823Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required
824Upto 450 mm sweep
825Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes.
826Supply of Recessed mounting 2x2 feet 36W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect.
827Supply of Recess mounting 2x2 feet 24 to 30W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect.
828Supply of LED 4ft 40W LED Tube light with a nominal system lumen output of 4000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 3000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 42W (including driver).
829Supply of Suspended mounting 36W LED Liner Batten Light, suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect.
830Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 21W (including driver).
831Supply of Surface mounting round 6 Watt 10 Watt , LED Down Lighter, suitable for 24Hr Continuous Operation, 660-1100 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect.
832Supply of Recess mounting round 12 Watt 15 Watt ,suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect
833Supply of Suspended/Surface mounting round 12 Watt 15 Watt Light,suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect
834Supply of Recess mounting square 20 Watt , suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect.
835Supplying of Bead Head light 31W fitting complete including connections etc.
836Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.complete in all respect
837Supplying of LED mirror light luminaire with 10Wwatt complete with electronic ballast, lamp including connection etc. complete as required.
838Supply of LED Flood light 50 Watt , suitable for 24Hr Continuous Operation, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, CCT 3000K, complete in all respect,
839Supplying and fixing brass batten/ angle holder including connection etc. as required.
840Supplying of 9 Watt 4 Star LED Wall Light Blub complete in all respect.
841Supplying of 9 Watt Decorative LED Wall Light complete in all respect.
842Supplying of 15 Watt decorative IP 66 LED UP-down Luminaire with wallsurface mounting using COB LED as light source. complete in all respect.
843Supplying of 7 Watt Step Light complete in all respect.
844Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan
845Supplying, erection, connecting, testing and commissioning of 400 mm Wall Fancomplete in all respect.
846Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.
847300mm EXHAUST FAN
848Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required
84940 A,25KA,FP MCCB
85063 A,25KA,FP MCCB
851100 A,30KA,FPMCCB
852125 A,36KA,FPMCCB
853160 A,25KA,FP MCCB
854200 A, 36KA,FPMCCB
855250 A, 36KA,FPMCCB
856320 A, 36KA,FPMCCB
857Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8586 Way Double Door
8598 way, Double door
86012 way, Double Door
86116 way, Double Door
862Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8634 Way Double door
8646 way Double door
8658 way Double door
86612 way Double door
867Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.)
8684 way (4 + 12), Double door
8698 way (4 + 24), Double door
870Supplying and fixing TP/FP sheet steel enclosure on surface/ recess. Suitable for upto 125 A 415 V MCCB complete with connections, testing and commissioning etc. as required.
871Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required
87240 amps SP MCB
87340 amps DP MCB
87463 amps DP MCB
87540 amps TP MCB
87663 amps TP MCB
87740 amps 4P MCB
87863 amps 4P MCB
879100 amps 4P MCB
880Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required
88140 amps
88263 amps
883Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required
88440 amps
88563 amps
886Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required.
88725 amps
88840 amps
88963 amps
890Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
891Single pole
892Double pole
893Triple pole
894Triple pole and neutral
895Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
896Supplying and fixing 1P LCD Energy Meter 5-30A with BOX
897Supplying and fixing 3Ph 4 W kWh Dir base mtg 240V 10- 60 A Energy Meter
898Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
899Supplying and fixing DP sheet steel enclosure on surface/ recessalong with 25/32 A 240 V \"C\" curve DP MCB complete withconnections, testing and commissioning etc. as required.
900Supplying and fixing 4P sheet steel enclosure on surface/ recess complete with connections, testing and commissioning etc. as required.
901Supplying and fixing TP/FP sheet steel enclosure on surface/ recess. Suitable for upto 125 A 415 V MCCB complete with connections, testing and commissioning etc. as required.
902Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
90390 mm dia (OD-90 mm & ID-76 mm nominal)
904Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.0mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCB\"s to be used.All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports.
905The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section.
906The minimum clearances between bus bars shall be as follows :
907Phase to phase - minimum 20mm
908Phase to neutral-minimum 15mm
909Main LT Panel
910Incoming :
9111 No 630 Amp. 4P MCCB of 35KA (Ics=Icu)Breaking Capacity
9121 No 500 Amp. 4P MCCB of 35KA (Ics=Icu)Breaking Capacity
9132 No 630 Amp. 4P CONTRACTOR
914Metering :
9152 Set of CT\"s one of 630/ 5Amp ratio for Multifunction Meter
9162 Set of CT\"s one of 630/ 5Amp ratio 27,47,59,81.
9172 Set of CT\"s one of 200/ 5Amp ratio for APFC relay.
9182 Set of Phase Indication Lamp.
919Bus Coupler :
9201 No 630 Amp. 4P MCCB of 35KA (Ics=Icu)Breaking Capacity
9211 No 630 Amp. 4P CONTRACTOR
922Bus Bar :
9232 No. 800 Amp. FP aluminimum bus bar of suitable length.
924Outgoing :
925Phase indication lamps on each outgoing to be provided.
926400 Amps FP MCCB of 35KA - 1 No
927320 Amps FP MCCB of 35KA - 2 No
928200 Amps FP MCCB of 35KA - 1 No
929125 Amps FP MCCB of 35KA - 4 No
930100 Amps FP MCCB of 35KA - 2 No
93163 Amps FP MCCB of 35KA - 4 No
9322 No. SPACE & SPARE
933Panel described as above
934CAPACITOR PANEL-100 KVAR
935SITC APFC Panel of 100 KVAR capacity suitable for operation on 415 + 5% Volt, 3 Phase, 50Hz, AC supply, having MPP type, resin bounded, static5,10,15,25 KVAR capacitors (without oil) in tier formationcomplete with following TPN MCCBas incomer of the panel, 11 step microprocessor based power factor controller relay capable to select the rating from 1 KVAR to multiples thereon up to max rating of the panel, current limiting contactors for each capacitors protected with MCBs, Ammeter (Analogue type) with CTs, Voltmeter (Analogue type) selector switches indicating lights, cooling fans for panel, earthing the panel with 2 Nos. 25mm x 5mm thick GI steel flat from existing earth bar, connection of APFC panel with suitable size 3.5 core aluminium conductor armoured XLPE cable from main LT panel (maximum length of cable 10 mtrs.) and compression glands etc. as reqd. The panel should have provision of timer based circuit in APFC relay to switch ON and OFF the static part automatically as and when requried. Capacity of Static capacitors should be accommodated from the overall rating of the panel and should be designed to switch in
936independently. The panel should be manufactured with 1.6mm thick CRCA sheet duly powder coated.
937Incoming
938One (1) No 200 Amp. 4P MCCB of 25 KABreaking capacity
939BUS BAR
9401 Set of 300 Amps TPN Aluminium Bus Bars
941OUT GOING
94202 No. 63 Amps. TP MCCB (25 KA)-25 KVAR
94301 No. 40 Amps. TP MCCB (25 KA)-15 KVAR
94403 No. 32 Amps. TP MCCB (25 KA)- 10 KVAR
94501 No. 25 Amps. TP MCCB (25 KA)- 5 KVAR
946Panel described as above
947STREET LIGHT PANEL (OUTDOOR TYPE) IP 65
948Incoming :
949One (1) No 63 Amp. 4P MCCB of 25KABreaking capacity
950Metering :
951One (1) No. SetsMultifunction Meter each incoming
952One (1) No. of Phase Indication Lamp each incoming
953Bus Bar :
954One (1) No. 80 Amp.TPN aluminimum bus bar of suitable length.
955Outgoing :
956Phase indication lamps on each outgoing to be provided.
9572 No. 32 Amp 4PMCB. (10 KA)
95820 No. 16 Amp DPMCB. (10 KA)
9592 No. SPACE & SPARE
960Panel described as above
961Power Panel-LHS
962Incoming :
9631 No 250 Amp. 4P MCCB of 25KABreaking capacity
964Metering :
9651 Set of CT\"s one of 250/ 5Amp ratio for Multifunction Meter
966One (1) Set of Phase Indication Lamp.
967Bus Bar :
9681 No. 300 Amp.TPN aluminimum bus bar of suitable length.
969Outgoing :
970Phase indication lamps on each outgoing to be provided.
9713 No. 63 Amp 4PMCB
9726 No. 40 Amp 4PMCB
973SPARE & SPACE- 2 No
974Panel described as above
975Power Panel-RHS
976Incoming :
9771 No 320 Amp. 4P MCCB of 35KABreaking capacity
978Metering :
9791 Set of CT\"s one of 320/ 5Amp ratio for Multifunction Meter
980One (1) Set of Phase Indication Lamp.
981Bus Bar :
9821 No. 400 Amp.TPN aluminimum bus bar of suitable length.
983Outgoing :
984Phase indication lamps on each outgoing to be provided.
9854 No. 100 Amp 4PMCB
9863 No. 63 Amp 4PMCB
9873 No. 40 Amp 4PMCB
988SPARE & SPACE- 2 No
989Panel described as above
990Light Panel-LHS
991Incoming :
9921 No 200 Amp. 4P MCCB of 25KABreaking capacity
993Metering :
9941 Set of CT\"s one of 200/ 5Amp ratio for Multifunction Meter
995One (1) Set of Phase Indication Lamp.
996Bus Bar :
9971 No. 250 Amp.TPN aluminimum bus bar of suitable length.
998Outgoing :
999Phase indication lamps on each outgoing to be provided.
10002 No. 63 Amp 4PMCB
10017 No. 40 Amp 4PMCB
1002SPARE & SPACE- 2 No
1003Panel described as above
1004Light Panel-RHS
1005Incoming :
10061 No 160 Amp. 4P MCCB of 25KABreaking capacity
1007Metering :
10081 Set of CT\"s one of 160/ 5Amp ratio for Multifunction Meter
1009One (1) Set of Phase Indication Lamp.
1010Bus Bar :
10111 No. 200 Amp.TPN aluminimum bus bar of suitable length.
1012Outgoing :
1013Phase indication lamps on each outgoing to be provided.
10141 No. 63 Amp 4PMCB
10158 No. 40 Amp 4PMCB
1016SPARE & SPACE- 2 No
1017Panel described as above
1018UPS PANEL
1019Incoming :
10202 No 125 Amp. 4P MCCB of 25KABreaking capacity
1021Metering :
10222 Set of CT\"s one of 125/ 5Amp ratio for Multifunction Meter
10232 Set of Phase Indication Lamp.
1024Bus Bar :
1025One (1) No. 160 Amp.TPN aluminimum bus bar of suitable length.
1026Outgoing :
1027Phase indication lamps on each outgoing to be provided.
10282 No. 63 Amp 4PMCB
10298 No. 40 Amp 4PMCB
10302 No. 40 Amp DPMCB
1031SPARE & SPACE- 2 No
1032Panel described as above
1033ELEVATOR PANEL 1&2
1034Incoming :
1035One (1) No 125 Amp. 4P MCCB of 25KABreaking capacity
1036Metering :
10371 Set of CT\"s one of 125/ 5Amp ratio for Multifunction Meter
10381 Set of Phase Indication Lamp.
1039Bus Bar :
1040One (1) No. 200 Amp.TPN aluminimum bus bar of suitable length.
1041Outgoing :
1042Phase indication lamps on each outgoing to be provided.
10433 No.63 Amp 4PMCCB. (25 KA)
10443 No. 40 Amp DPMCB. (10 KA)
1045SPARE & SPACE
1046Panel described as above
1047ELEVATOR PANEL 3
1048Incoming :
1049One (1) No 80 Amp. 4P MCCB of 25KABreaking capacity
1050Metering :
10511 Set of CT\"s one of 80/ 5Amp ratio for Multifunction Meter
10521 Set of Phase Indication Lamp.
1053Bus Bar :
1054One (1) No. 100 Amp.TPN aluminimum bus bar of suitable length.
1055Outgoing :
1056Phase indication lamps on each outgoing to be provided.
10572 No.63 Amp 4PMCCB. (25 KA)
10582 No.40 Amp DPMCB. (10 KA)
1059SPARE & SPACE
1060Panel described as above
1061Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each
1062Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required.
1063Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
1064Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
1065Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
1066Providing and laying earth connection from earth electrodewith 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earthelectrode including connection with G.I. thimble excavation andre-filling as required.
1067Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
1068Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.
1069Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes:
10702 Pair (4 core)
1071Providing, laying, connecting and testing of multi-core telephone armoured cable of conductor size 0.5mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable along wall or ceiling or through existing pipe.
1072100 Pair telephone cable
107350 Pair telephone cable
107420 Pair telephone cable
107510 Pair telephone cable
10765 Pair telephone cable
1077Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted.
10785 Pair tag block
107910 pair tag block
108020 pair tag block
108150 pair tag block
1082100 pair tag block
1083Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
108420mm dia PVC conduit
108525mm dia PVC conduit
108632mm dia PVC conduit
1087Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required
10881 or 2 Module (75mmX75mm)
1089Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
1090Telephone socket outlet
1091TV antenna socket outlet
1092Bell Push
1093RJ-45 Data Socket outlet
1094Supplying and fixing call bell/ buzzer suitable for single phase,230 V, complete as required.
1095Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
10961 run of cable
1097Providing, laying, connecting and testing of unarmoured TV cable RG-6 PVC insulated cable along wall or ceiling or through existing pipe.
1098Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
1099Up to 35 sq.mm.
1100Above 35 sq.mm. and up to 95 sq.mm.
1101Above 95 sq.mm. and upto 185 sq.mm.
1102Above 185 sq.mm. and up to 400 sq.mm.
1103Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, rotective covering and refilling the trench etc as required
1104Up to 35 sq.mm.
1105Above 35 sq.mm. and up to 95 sq.mm.
1106Above 95 sq.mm. and upto 185 sq.mm.
1107Above 185 sq.mm. and up to 400 sq.mm.
1108Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
1109Up to 35 sq.mm.
1110Above 35 sq.mm. and up to 95 sq.mm.
1111Above 95 sq.mm. and upto 185 sq.mm.
1112Above 185 sq.mm. and up to 400 sq.mm.
1113Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
1114Up to 35 sq.mm.
1115Above 35 sq.mm. and up to 95 sq.mm.
1116Above 95 sq.mm. and upto 185 sq.mm.
1117Above 185 sq.mm. and up to 400 sq.mm.
1118Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required
1119Up to 35 sq.mm.
1120Above 35 sq.mm. and up to 95 sq.mm.
1121Above 95 sq.mm. and upto 185 sq.mm.
1122Above 185 sq.mm. and up to 400 sq.mm.
1123Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required
1124Upto 35 sq. mm (clamped with 1mm thick saddle
1125Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp
1126Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp
1127Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
1128Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
1129Upto 35 sq. mm (clamped with 1mm thick saddle)
1130Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
1131Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
1132Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
1133Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment
11343.5 x 400 sq.mm.
11353.5 x 300 sq.mm.
11363.5 x 240 sq.mm.
11373.5 x 185 sq.mm
11383.5 x 150 sq.mm
11393.5 x 120 sq.mm
11403.5 x 95 sq.mm
11413.5 x 70 sq.mm
11423.5 x 50 sq.mm
11433.5 x 35 sq.mm
11443.5 x 25 sq.mm.
11454 x 25 sq.mm
11464 x 16 sq.mm
11474 x 10 sq.mm
11484 x 6 sq.mm
11493 x 6 sq.mm
11502 x 16 sq.mm,
11512 x 10 sq.mm,
11522 x 6 sq.mm,
1153Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.
11542 X 6 sq. mm (19mm)
11552 X 10 sq. mm (19mm)
11562 X 16 sq. mm (22mm)
11573½ X 25 sq. mm (28mm)
11583½ X 35 sq. mm (32mm)
11593½ X 50 sq. mm (35mm)
11603½ X 70 sq. mm (38mm)
11613½ X 95 sq. mm (45mm)
11623½ X 120 sq. mm (45mm)
11633½ X 150 sq. mm (50mm)
11643½ X 185 sq. mm (57mm)
11653½ X 225 sq. mm (62mm)
11663½ X 240 sq. mm (62mm)
11673½ X 300 sq. mm (70mm)
11683½ X 400 sq. mm (82mm)
11694 X 10 sq. mm (25mm)
11704 X 16 sq. mm (28mm)
1171Providing, laying and fixing following dia G.I. pipe (mediumclass) in ground complete with G.I. fittings including trenching(75 cm deep)and re-filling etc as required
1172100 mm dia
1173Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
1174100mm dia
1175150 mm dia
1176250 mm dia
1177300 mm dia
1178Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioningand protective covering etc., complete as required.
117990 mm dia (OD-90 mm & ID-76 mm nominal)
1180Category-II (Civil (02)
1181Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
1182Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
1183Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors.
1184Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work.
1185Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion)
1186Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface ofthe substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete:With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
1187Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
1188Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) [ M-20 ]
1189All works upto plinth level
1190Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
1191All works Above plinth level
1192M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work.
1193Providing and laying damp-proof course 25 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size).
1194Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
1195Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
1196Cement mortar 1:6 (1 cement : 6 coarse sand)
1197Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
1198Cement mortar 1:4 (1 cement :4 coarse sand)
1199Extra for forming cavity 5 cm to 11.5 cm wide in cavity walls with necessary weep and vent holes including use of cores and cost of providing and fixing bitumastic coated M .S. ties 300 mm long of 25x3 mm section at not less than 3 ties per sqm as per approved design.
1200Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry.
1201Providing machine made Wire Cut Bricks where edges are sharp and borders are straight and Size of8.5\"x 4\"x3\"having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%. Thickness of 230mm wall
1202Supply and Laying a water soluble penetrative solution for waterproofing of masonry building material & Nano technology based as it provides molecular level hydrophobicity to inorganic substrate .The product is based on organosilicon chemistry, hence reacts with the inorganic substrate surface, seals the surface uto a depth of 2-3 mm and provides long service life where Nano size allows penetration deep into substrate that provides 20+ years water repellency.(Zycosil/Pratt & Lamber or Equivalent) including cost of all materials, labour tools and plants etc. required for proper completion of the work.
1203P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. (TMT Fe-500)
120415mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand of 2.25 F.M.
120515 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand
120615 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand
120712mm thick plaster in 1:3 on ceiling and soffits of stairs upto floor two level.
1208Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any Size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
1209Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to 1S:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily,Glazed Vitrified tiles Matt/Antiskid finish of size 600 x 600 mm
1210Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
1211Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm. Granite stone slab of all colour and texture
1212Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor).
1213Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
1214(a) Single leaf
1215(b) Double leaf
1216Both side laminated
1217Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin- charge.Extruded section profile size 48x40 mm
1218Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash andmullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.
1219Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speeds Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.
1220Using R4 series with frame (115 mm & above) x (45 mm & above) & both glazed and fly screen sash (44 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coatedhandle on every glazed panel along with multipoint locking system. (Height above 1.8m)
1221Wall Painting with plastic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats (For Internal wall surface)
1222Wall Painting with plastic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats (For Internal ceiling surface)
1223Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
1224Natural Mud plaster+ paint Aggregate made up of Lime, Clay & Additives in given proportion to get the desired Texture.Shade, Texture and number of coatsas per architects approval to get the desired finished
1225Cost of Artistic Mural & painting as per Design received from Architect Incharge.
1226Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to
1227IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick
1228jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
1229Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete.
1230Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm .
1231Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete
1232(a) 300 mm x 10mm
1233(b) 200 x 10mm
1234Providing and fixing stainless steel handles with screws etc. complete (a) 150 mm
1235Float glass panes 4 mm thick glass pane (weight not less than 10 kg/sqm).
1236Centering and shuttering including strutting, propping etc. and removal of form for:
1237Foundations, footings, bases of columns, etc. for mass concrete
1238Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
1239Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick
1240Columns, Pillars, Piers, Abutments, Posts and Struts
1241Supply & fixing clay tiles of 10X16 inches on roof including the cost of Ridge, typical caly tile, edge tiles and inlcusion of glass tiles in color and finish as per drawing approved from Architect in charge, and supply of all materials labours & tools etc required for safe erection and cost of adhesive, waterproof membrane and MS frame of L profile/rectangular hollow sections required for fixing and supprting the tiles., also includes the cost of all the necessary fitting and required for completion of the work as per Engineer in charge.
1242INTERNAL W/S AND SANITATION (02 Nos)
1243Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
1244W.C. pan with ISI marked white solid plastic seat and lid
1245Providing and fixing white vitreous chinaextended wall mounting type water closet of size 780x370x690 mm of approved shape including providing & fixing white viterous china cistern with dual flush fittings of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litres ) includung seat cover & cistern fittings nuts , bolts and gaskets etc complete.
1246Providing & fixing toilet paper holder
1247C.P. brass
1248Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
1249Providing and fixing Jaquar Make Hand Shower (Health Faucet) with 8mm Dia,1.2 Meter Long Flexible Tube & Wall Hook of quality and make as approved by Engineer - in - charge.
1250Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
1251White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap
1252Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-
1253(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
1254Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
1255Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
1256Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
1257Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
1258Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern & jet)
125915 mm nominal bore
1260Providing and fixing uplasticised PVC connection pipe with brass unions :
126145 cm length
126215 mm nominal bore
1263Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
1264100 mm diameter
1265Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
126615 mm nominal bore
1267Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.
126815 mm nominal dia
1269Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
1270600 mm long towel rail with total length of 645 mm, width78 mm and effective height of 88 mm, weighing not lessthan 190 gms.
1271Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
1272Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever required
1273Kitchen sink with drain board
1274510x1040 mm bowl depth 200 mm
1275Kitchen sink without drain board
1276610x510 mm bowl depth 200 mm
1277Providing & fixing PVC waste pipe for sink including PVC waste fittings Complete
1278Flexible Pipe
127932mm Dia
1280Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
128115mm nominal bore
1282Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
128315mm nominal bore
1284Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge.
1285Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (Including C.I. trap for standard urinal with vent arm with operating and other couplings in C.P.brass: 50 mm dia)
1286Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as perdirection of Engineer-in-charge and finished smooth.
1287Granite Stone of approved shade
1288Providing and fixing of Kent Elite Plus Water Purifier (RO+UV+UF+TDS Control) with flow rate (50L/hr)including all its accessories, complete in all respect including testing etc.
1289Providing and fixing of Water Cooler (Voltas Make) including all its accessories, complete in all respect including testing etc.
1290Providing and fixing of storage type (pressurised type) electrichot water heater copper sheet container, 25 mm thickinsulation, stove enamelled M.S. jacket thermostatically controlled immersion heater with pilot neon lamp, suitable length of electrical cable and 15 amp 3 pin plug top, complete in all respect including testing etc.
1291Capacity 25 Liters
1292Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
1293Concealed work, including cutting chases and making good the walls etc.
1294For Internal Toilet
129515 mm nominal outer dia Pipes
129620 mm nominal outer dia Pipes
1297Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
1298Internal work - Exposed on wall
129920 mm nominal bore
130025 mm nominal bore
130132 mm nominal bore
130240 mm nominal bore
1303Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall
1304Terrace loop & Tank Filling Pipe
130520 mm nominal bore
130625 mm nominal bore
130732 mm nominal bore
130840 mm nominal bore
130950 mm nominal bore
131065 mm nominal bore
131180 mm nominal bore
1312Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :
131320mm diameter pipe
131425mm diameter pipe
131532mm diameter pipe
131640mm diameter pipe
131750mm diameter pipe
131865mm diameter pipe
131980mm diameter pipe
1320Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :
132120mm diameter pipe
132225mm diameter pipe
132332mm diameter pipe
132440mm diameter pipe
132550mm diameter pipe
132665mm diameter pipe
132780mm diameter pipe
1328Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
1329For vertical pipe connection with terrace ringmain
133020 mm nominal bore
133125mm nominal bore
133232mm nominal bore
133340mm nominal bore
133450mm nominal bore
133565mm nominal bore
133680mm nominal bore
1337Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
133825 to 40 mm nominal bore
133950 to 80 mm nominal bore
1340Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./H.P.H.D. plastic ball.
134115 mm nominal bore, 105 mm long, weighing not less than 138 gms
134220 mm nominal bore, 120 mm long, weighing not less than 198 gms
134325 mm nominal bore, 152 mm long, weighing not less than 440 gms
134440 mm nominal bore, 206 mm long, weighing not less than 690 gms
134550 mm nominal bore, 242 mm long, weighing not less than 1240 gms
1346Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
1347Providing, Fixing, Testing & Commissioning of XLPE Insulation of 9mm thickness on hot water supply pipes. Astral orequivalent approved complete in all respect as directed by Engineer-in-charge.
134815mm dia (9 mm thickness)
134920mm dia (9 mm thickness)
135025mm dia (9 mm thickness)
135132mm dia (9 mm thickness)
135240mm dia (9 mm thickness)
135350mm dia (9 mm thickness)
1354Supply, fixing, testing and commissioning of following Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve - IP65CB - 230VAC, as per specifications:-
1355Lehry Make Automatic OHT Level Control System Consist of Following Items
13561) LEHRY Make On-Off Type Electrical Actuator Single Phase 220V AC Operated Wafer Type Butterfly Valve with CI Body & SS Disc 2) Level Float Switch- 5M 3) Control Box (a) IP 65 Finishing(250 x 160 x 115)mm (b) LED Lamps: Tank FULL, Tank EMPTY, Power (c) Power supply toggle switch (d) Accepts 230V Single Phase power supply and provides 24VAC to float switch and 230VAC to valve coil. (e) Accepts NO/NC feedback from float switch.
135740mm
135850mm
135965mm
136080mm
1361Providing and fixing MS pipe puddle flanges of required size with 600mm long with 6mm thick MS plate of size 300mm x 300mmof suitable size properly fixed in RCC walls of water tanks, including necessary welding complete in all respect as per details shown on darwings and directions of Engineeer-in-charge for water tanks.
136225mm dia.
136332mm dia.
136440mm dia.
136550mm dia.
136665mm dia.
136780mm dia.
1368100mm dia.
1369150mm dia.
1370200mm dia.
1371250mm dia.
1372Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
1373110 mm dia (for rain water)
1374Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion.
1375Single Push Fit Coupler
1376110 mm dia
1377Single tee with door
1378110x110x110 mm
1379Plain bend 87.5 deg
1380110 mm dia
1381Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
1382110 mm dia
1383Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
1384Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.
1385All kind of soil
1386Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia.
1387Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design:
1388100mm dia SWpipe
1389Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes.
1390Internal Toilet (Soil & Waste Pipe)
139175 mm
1392110 mm
1393Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.
1394Bend without door (45°)
139575mm
1396110mm
1397Bend without door (87.5°)
139875mm bend
1399110mm
1400Y\" Fitting without door
140175mm
1402110mm
1403Single Tee without door
140475mm
1405110 mm
1406Single Tee with door
140775mm
1408110 mm
1409Bend with door (87.5°)
141075mm
1411110 mm
1412Clean Out Plug (COP)
141375mm
1414110 mm
1415Reduced \"Y\" Fitting without door
1416110mm x 75mm
1417Reduced Tee with door
1418110mm x 75mm
1419Coupler
142075mm
1421110mm
1422Vent Cowl
1423110mm
1424Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc.
1425For Wash basin & Urinal
142632mm dia. Pipe
1427Elbow (45°)
142832mm
1429Elbow (90°)
143032mm
1431T fitting
143232mm
143350mm
1434Coupler
143532mm
1436Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge.
1437110mm x 75mm x 50mm/40mm (Toilet)
1438Providing, fixing, jointing and testing , ofPVC NahaniTrap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge.
1439110mm x 75mm (Toilet & Kitchen)
1440Providing and fixing PTMT grating of approved quality and colour.
1441Rectangular type with openable circular lid
1442150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony)
1443Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
1444150 x 100mm size P-type
1445With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1446Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete:
1447100 mm diameter
1448Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.
1449All kind of soil
1450Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia.
1451Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design:
1452100mm dia SWpipe
1453INTERNAL ELECTRIFICATION WORK
1454Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
1455Group - C
1456Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
1457Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required
1458Group -A
1459Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
14602 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
14612 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
14622 X 4 sq. mm + 1 X 4 sq. mm earth wire
14632 X 6 sq. mm + 1 X 4 sq. mm earth wire
14642 x 10 sq.mm + 1 x 6sq.mm. earth wire
14652 x 16 sq.mm + 1 x 6sq.mm. earth wire
14664 x 6 sq.mm + 2 x 6 sq.mm. earth wire
14674 x 10 sq.mm + 2 x 6 sq.mm. earth wire
14684 x 16 sq.mm + 2 x 6sq.mm. earth wire
1469Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required.
1470Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1471Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
1472Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required.
1473Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
1474Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required
1475Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
14765/6 A switch
14773 pin 5/6 A socket outlet
1478Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1479Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
1480Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
1481Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
1482Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required
1483Upto 450 mm sweep
1484Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes.
1485Supply of Recessed mounting 2x2 feet 36W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect.
1486Supply of Recess mounting 2x2 feet 24 to 30W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect.
1487Supply of LED 4ft 40W LED Tube light with a nominal system lumen output of 4000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 3000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 42W (including driver).
1488Supply of Suspended mounting 36W LED Liner Batten Light, suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect.
1489Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 21W (including driver).
1490Supply of Surface mounting round 6 Watt 10 Watt , LED Down Lighter, suitable for 24Hr Continuous Operation, 660-1100 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect.
1491Supply of Recess mounting round 12 Watt 15 Watt ,suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect
1492Supply of Suspended/Surface mounting round 12 Watt 15 Watt Light,suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect
1493Supply of Recess mounting square 20 Watt , suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect.
1494Supplying of Bead Head light 31W fitting complete including connections etc.
1495Supplying of Bulkhead type light fitting complete with, wire guard, holder, electronic ballast 1 x 10 W lamp including connections etc.complete in all respect
1496Supplying of LED mirror light luminaire with 10Wwatt complete with electronic ballast, lamp including connection etc. complete as required.
1497Supply of LED Flood light 50 Watt , suitable for 24Hr Continuous Operation, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70, CCT 3000K, complete in all respect,
1498Supplying and fixing brass batten/ angle holder including connection etc. as required.
1499Supplying of 9 Watt 4 Star LED Wall Light Blub complete in all respect.
1500Supplying of 9 Watt Decorative LED Wall Light complete in all respect.
1501Supplying of 15 Watt decorative IP 66 LED UP-down Luminaire with wallsurface mounting using COB LED as light source. complete in all respect.
1502Supplying of 7 Watt Step Light complete in all respect.
1503Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan
1504Supplying, erection, connecting, testing and commissioning of 400 mm Wall Fancomplete in all respect.
1505Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.
1506300mm EXHAUST FAN
1507Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required
150840 A,25KA,FP MCCB
150963 A,25KA,FP MCCB
1510100 A,30KA,FPMCCB
1511125 A,36KA,FPMCCB
1512160 A,25KA,FP MCCB
1513200 A, 36KA,FPMCCB
1514250 A, 36KA,FPMCCB
1515320 A, 36KA,FPMCCB
1516Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
15176 Way Double Door
15188 way, Double door
151912 way, Double Door
152016 way, Double Door
1521Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
15224 Way Double door
15236 way Double door
15248 way Double door
152512 way Double door
1526Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.)
15274 way (4 + 12), Double door
15288 way (4 + 24), Double door
1529Supplying and fixing TP/FP sheet steel enclosure on surface/ recess. Suitable for upto 125 A 415 V MCCB complete with connections, testing and commissioning etc. as required.
1530Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required
153140 amps SP MCB
153240 amps DP MCB
153363 amps DP MCB
153440 amps TP MCB
153563 amps TP MCB
153640 amps 4P MCB
153763 amps 4P MCB
1538100 amps 4P MCB
1539Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required
154040 amps
154163 amps
1542Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required
154340 amps
154463 amps
1545Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required.
154625 amps
154740 amps
154863 amps
1549Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1550Single pole
1551Double pole
1552Triple pole
1553Triple pole and neutral
1554Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
1555Supplying and fixing 1P LCD Energy Meter 5-30A with BOX
1556Supplying and fixing 3Ph 4 W kWh Dir base mtg 240V 10- 60 A Energy Meter
1557Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
1558Supplying and fixing DP sheet steel enclosure on surface/ recessalong with 25/32 A 240 V \"C\" curve DP MCB complete withconnections, testing and commissioning etc. as required.
1559Supplying and fixing 4P sheet steel enclosure on surface/ recess complete with connections, testing and commissioning etc. as required.
1560Supplying and fixing TP/FP sheet steel enclosure on surface/ recess. Suitable for upto 125 A 415 V MCCB complete with connections, testing and commissioning etc. as required.
1561Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
156290 mm dia (OD-90 mm & ID-76 mm nominal)
1563SUBHEAD: - IV - MV PANEL
1564Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.0mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCB\"s to be used.All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports.
1565The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section.
1566The minimum clearances between bus bars shall be as follows :
1567Phase to phase - minimum 20mm
1568Phase to neutral-minimum 15mm
1569Main LT Panel
1570Incoming :
15711 No 630 Amp. 4P MCCB of 35KA (Ics=Icu)Breaking Capacity
15721 No 500 Amp. 4P MCCB of 35KA (Ics=Icu)Breaking Capacity
15732 No 630 Amp. 4P CONTRACTOR
1574Metering :
15752 Set of CT\"s one of 630/ 5Amp ratio for Multifunction Meter
15762 Set of CT\"s one of 630/ 5Amp ratio 27,47,59,81.
15772 Set of CT\"s one of 200/ 5Amp ratio for APFC relay.
15782 Set of Phase Indication Lamp.
1579Bus Coupler :
15801 No 630 Amp. 4P MCCB of 35KA (Ics=Icu)Breaking Capacity
15811 No 630 Amp. 4P CONTRACTOR
1582Bus Bar :
15832 No. 800 Amp. FP aluminimum bus bar of suitable length.
1584Outgoing :
1585Phase indication lamps on each outgoing to be provided.
1586400 Amps FP MCCB of 35KA - 1 No
1587320 Amps FP MCCB of 35KA - 2 No
1588200 Amps FP MCCB of 35KA - 1 No
1589125 Amps FP MCCB of 35KA - 4 No
1590100 Amps FP MCCB of 35KA - 2 No
159163 Amps FP MCCB of 35KA - 4 No
15922 No. SPACE & SPARE
1593Panel described as above
1594CAPACITOR PANEL-100 KVAR
1595SITC APFC Panel of 100 KVAR capacity suitable for operation on 415 + 5% Volt, 3 Phase, 50Hz, AC supply, having MPP type, resin bounded, static5,10,15,25 KVAR capacitors (without oil) in tier formationcomplete with following TPN MCCBas incomer of the panel, 11 step microprocessor based power factor controller relay capable to select the rating from 1 KVAR to multiples thereon up to max rating of the panel, current limiting contactors for each capacitors protected with MCBs, Ammeter (Analogue type) with CTs, Voltmeter (Analogue type) selector switches indicating lights, cooling fans for panel, earthing the panel with 2 Nos. 25mm x 5mm thick GI steel flat from existing earth bar, connection of APFC panel with suitable size 3.5 core aluminium conductor armoured XLPE cable from main LT panel (maximum length of cable 10 mtrs.) and compression glands etc. as reqd. The panel should have provision of timer based circuit in APFC relay to switch ON and OFF the static part automatically as and when requried. Capacity of Static capacitors should be accommodated from the overall rating of the panel and should be designed to switch in
1596independently. The panel should be manufactured with 1.6mm thick CRCA sheet duly powder coated.
1597Incoming
1598One (1) No 200 Amp. 4P MCCB of 25 KABreaking capacity
1599BUS BAR
16001 Set of 300 Amps TPN Aluminium Bus Bars
1601OUT GOING
160202 No. 63 Amps. TP MCCB (25 KA)-25 KVAR
160301 No. 40 Amps. TP MCCB (25 KA)-15 KVAR
160403 No. 32 Amps. TP MCCB (25 KA)- 10 KVAR
160501 No. 25 Amps. TP MCCB (25 KA)- 5 KVAR
1606Panel described as above
1607STREET LIGHT PANEL (OUTDOOR TYPE) IP 65
1608Incoming :
1609One (1) No 63 Amp. 4P MCCB of 25KABreaking capacity
1610Metering :
1611One (1) No. SetsMultifunction Meter each incoming
1612One (1) No. of Phase Indication Lamp each incoming
1613Bus Bar :
1614One (1) No. 80 Amp.TPN aluminimum bus bar of suitable length.
1615Outgoing :
1616Phase indication lamps on each outgoing to be provided.
16172 No. 32 Amp 4PMCB. (10 KA)
161820 No. 16 Amp DPMCB. (10 KA)
16192 No. SPACE & SPARE
1620Panel described as above
1621Power Panel-LHS
1622Incoming :
16231 No 250 Amp. 4P MCCB of 25KABreaking capacity
1624Metering :
16251 Set of CT\"s one of 250/ 5Amp ratio for Multifunction Meter
1626One (1) Set of Phase Indication Lamp.
1627Bus Bar :
16281 No. 300 Amp.TPN aluminimum bus bar of suitable length.
1629Outgoing :
1630Phase indication lamps on each outgoing to be provided.
16313 No. 63 Amp 4PMCB
16326 No. 40 Amp 4PMCB
1633SPARE & SPACE- 2 No
1634Panel described as above
1635Power Panel-RHS
1636Incoming :
16371 No 320 Amp. 4P MCCB of 35KABreaking capacity
1638Metering :
16391 Set of CT\"s one of 320/ 5Amp ratio for Multifunction Meter
1640One (1) Set of Phase Indication Lamp.
1641Bus Bar :
16421 No. 400 Amp.TPN aluminimum bus bar of suitable length.
1643Outgoing :
1644Phase indication lamps on each outgoing to be provided.
16454 No. 100 Amp 4PMCB
16463 No. 63 Amp 4PMCB
16473 No. 40 Amp 4PMCB
1648SPARE & SPACE- 2 No
1649Panel described as above
1650Light Panel-LHS
1651Incoming :
16521 No 200 Amp. 4P MCCB of 25KABreaking capacity
1653Metering :
16541 Set of CT\"s one of 200/ 5Amp ratio for Multifunction Meter
1655One (1) Set of Phase Indication Lamp.
1656Bus Bar :
16571 No. 250 Amp.TPN aluminimum bus bar of suitable length.
1658Outgoing :
1659Phase indication lamps on each outgoing to be provided.
16602 No. 63 Amp 4PMCB
16617 No. 40 Amp 4PMCB
1662SPARE & SPACE- 2 No
1663Panel described as above
1664Light Panel-RHS
1665Incoming :
16661 No 160 Amp. 4P MCCB of 25KABreaking capacity
1667Metering :
16681 Set of CT\"s one of 160/ 5Amp ratio for Multifunction Meter
1669One (1) Set of Phase Indication Lamp.
1670Bus Bar :
16711 No. 200 Amp.TPN aluminimum bus bar of suitable length.
1672Outgoing :
1673Phase indication lamps on each outgoing to be provided.
16741 No. 63 Amp 4PMCB
16758 No. 40 Amp 4PMCB
1676SPARE & SPACE- 2 No
1677Panel described as above
1678UPS PANEL
1679Incoming :
16802 No 125 Amp. 4P MCCB of 25KABreaking capacity
1681Metering :
16822 Set of CT\"s one of 125/ 5Amp ratio for Multifunction Meter
16832 Set of Phase Indication Lamp.
1684Bus Bar :
1685One (1) No. 160 Amp.TPN aluminimum bus bar of suitable length.
1686Outgoing :
1687Phase indication lamps on each outgoing to be provided.
16882 No. 63 Amp 4PMCB
16898 No. 40 Amp 4PMCB
16902 No. 40 Amp DPMCB
1691SPARE & SPACE- 2 No
1692Panel described as above
1693ELEVATOR PANEL 1&2
1694Incoming :
1695One (1) No 125 Amp. 4P MCCB of 25KABreaking capacity
1696Metering :
16971 Set of CT\"s one of 125/ 5Amp ratio for Multifunction Meter
16981 Set of Phase Indication Lamp.
1699Bus Bar :
1700One (1) No. 200 Amp.TPN aluminimum bus bar of suitable length.
1701Outgoing :
1702Phase indication lamps on each outgoing to be provided.
17033 No.63 Amp 4PMCCB. (25 KA)
17043 No. 40 Amp DPMCB. (10 KA)
1705SPARE & SPACE
1706Panel described as above
1707ELEVATOR PANEL 3
1708Incoming :
1709One (1) No 80 Amp. 4P MCCB of 25KABreaking capacity
1710Metering :
17111 Set of CT\"s one of 80/ 5Amp ratio for Multifunction Meter
17121 Set of Phase Indication Lamp.
1713Bus Bar :
1714One (1) No. 100 Amp.TPN aluminimum bus bar of suitable length.
1715Outgoing :
1716Phase indication lamps on each outgoing to be provided.
17172 No.63 Amp 4PMCCB. (25 KA)
17182 No.40 Amp DPMCB. (10 KA)
1719SPARE & SPACE
1720Panel described as above
1721SUBHEAD: - V - EARTHING
1722Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each
1723Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required.
1724Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
1725Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
1726Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
1727Providing and laying earth connection from earth electrodewith 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earthelectrode including connection with G.I. thimble excavation andre-filling as required.
1728Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
1729Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.
1730Supplying, drawing, connecting and testing of 0.5 mm dia annealed copper conductor PVC insulated PVC sheathed telephone wire in existing conduit/wire way duct etc. as required of following sizes:
17312 Pair (4 core)
1732Providing, laying, connecting and testing of multi-core telephone armoured cable of conductor size 0.5mm dia annealed copper conductor PVC insulated PVC sheathed jelly filled (as per DOT specification) cable along wall or ceiling or through existing pipe.
1733100 Pair telephone cable
173450 Pair telephone cable
173520 Pair telephone cable
173610 Pair telephone cable
17375 Pair telephone cable
1738Providing, fixing connecting and testing of under noted size of solderless telephone tag block Krone make in surface/recess in wall required size of M.S. box with hinged lockable cover duly stove enamel painted.
17395 Pair tag block
174010 pair tag block
174120 pair tag block
174250 pair tag block
1743100 pair tag block
1744Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
174520mm dia PVC conduit
174625mm dia PVC conduit
174732mm dia PVC conduit
1748Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required
17491 or 2 Module (75mmX75mm)
1750Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
1751Telephone socket outlet
1752TV antenna socket outlet
1753Bell Push
1754RJ-45 Data Socket outlet
1755Supplying and fixing call bell/ buzzer suitable for single phase,230 V, complete as required.
1756Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
17571 run of cable
1758Providing, laying, connecting and testing of unarmoured TV cable RG-6 PVC insulated cable along wall or ceiling or through existing pipe.
1759Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
1760Up to 35 sq.mm.
1761Above 35 sq.mm. and up to 95 sq.mm.
1762Above 95 sq.mm. and upto 185 sq.mm.
1763Above 185 sq.mm. and up to 400 sq.mm.
1764Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, rotective covering and refilling the trench etc as required
1765Up to 35 sq.mm.
1766Above 35 sq.mm. and up to 95 sq.mm.
1767Above 95 sq.mm. and upto 185 sq.mm.
1768Above 185 sq.mm. and up to 400 sq.mm.
1769Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
1770Up to 35 sq.mm.
1771Above 35 sq.mm. and up to 95 sq.mm.
1772Above 95 sq.mm. and upto 185 sq.mm.
1773Above 185 sq.mm. and up to 400 sq.mm.
1774Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
1775Up to 35 sq.mm.
1776Above 35 sq.mm. and up to 95 sq.mm.
1777Above 95 sq.mm. and upto 185 sq.mm.
1778Above 185 sq.mm. and up to 400 sq.mm.
1779Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required
1780Up to 35 sq.mm.
1781Above 35 sq.mm. and up to 95 sq.mm.
1782Above 95 sq.mm. and upto 185 sq.mm.
1783Above 185 sq.mm. and up to 400 sq.mm.
1784Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required
1785Upto 35 sq. mm (clamped with 1mm thick saddle
1786Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp
1787Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp
1788Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
1789Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
1790Upto 35 sq. mm (clamped with 1mm thick saddle)
1791Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
1792Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
1793Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
1794Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment
17953.5 x 400 sq.mm.
17963.5 x 300 sq.mm.
17973.5 x 240 sq.mm.
17983.5 x 185 sq.mm
17993.5 x 150 sq.mm
18003.5 x 120 sq.mm
18013.5 x 95 sq.mm
18023.5 x 70 sq.mm
18033.5 x 50 sq.mm
18043.5 x 35 sq.mm
18053.5 x 25 sq.mm.
18064 x 25 sq.mm
18074 x 16 sq.mm
18084 x 10 sq.mm
18094 x 6 sq.mm
18103 x 6 sq.mm
18112 x 16 sq.mm,
18122 x 10 sq.mm,
18132 x 6 sq.mm,
1814Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.
18152 X 6 sq. mm (19mm)
18162 X 10 sq. mm (19mm)
18172 X 16 sq. mm (22mm)
18183½ X 25 sq. mm (28mm)
18193½ X 35 sq. mm (32mm)
18203½ X 50 sq. mm (35mm)
18213½ X 70 sq. mm (38mm)
18223½ X 95 sq. mm (45mm)
18233½ X 120 sq. mm (45mm)
18243½ X 150 sq. mm (50mm)
18253½ X 185 sq. mm (57mm)
18263½ X 225 sq. mm (62mm)
18273½ X 240 sq. mm (62mm)
18283½ X 300 sq. mm (70mm)
18293½ X 400 sq. mm (82mm)
18304 X 10 sq. mm (25mm)
18314 X 16 sq. mm (28mm)
1832Providing, laying and fixing following dia G.I. pipe (mediumclass) in ground complete with G.I. fittings including trenching(75 cm deep)and re-filling etc as required
1833100 mm dia
1834Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
1835100mm dia
1836150 mm dia
1837250 mm dia
1838300 mm dia
1839Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioningand protective covering etc., complete as required.
184090 mm dia (OD-90 mm & ID-76 mm nominal)
1841Site Development Works
1842Internal Pathways: Providing and fixing of exposed brickwork in Flooring (407.94 Sqm)
1843Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. (DSR 2.8.1)
1844UNDER EDGE SIDE
1845Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. (DSR 4.1.8)
1846UNDER EDGE SIDE
1847UNDER PATHWAY
1848M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work.
1849Providing and fixing exposed brick flooring with modular common burnt clay bricks, machine made bricks: Indian chamfered and classic belgian rough bricks where edges are sharp and borders are straight and Size of200X100X40 for belgian rough and 230X110X25 for Indian chamfered having Smooth surface finish with Compression Strength should be less than 105 kg/sq cm and Water absorption should not exceed 20%on a bed of 12 mm cement mortar, to be laid in pattern as per drawing approved from Architect in charge including filling the joints with same mortar (make Prayag Clay Products or equivalent)
1850AR Pathway
1851External Water Supply , Drain, Tubewell & RWH
1852SEWERAGE & WATER SUPPLY SYSTEM
1853Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.
1854up to 1.50 m depth
1855Pipes 80 mm to 300 mmdiameter
18561.50 m to 3.00 m depth
1857Pipes 80 mm to 300 mmdiameter
1858Opentimbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)
1859Depth not exceeding 1.5 meter
1860Depth 1.5 to3.00meter
1861Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete.
1862150 mm.dia. RCCPipes
1863250 mm.dia. RCCPipes
1864300 mm.dia. RCCPipes
1865Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design
1866150 mm.dia. RCCPipes
1867250 mm.dia. RCCPipes
1868300 mm.dia. RCCPipes
1869Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design.
1870Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).
1871With common burnt clay FPS (non modular) bricks of class designation 75
1872(i) For Sewer Line
1873Extra for depth for manholes:
1874Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5
1875Inside size 90x120cms and 90cms deep including CI cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg).
1876With common burnt clay FPS (non modular) bricks of class designation 75
1877(i) For Sewer Line
1878Extra for depth for manholes:
1879Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5
1880Providing orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
1881Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. (external work)
188280mm nominal bore.
188365mm nominal bore.
188450mm nominal bore.
188540mm nominal bore.
188632mm nominal bore.
188725mm nominal bore.
1888Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
188980mm nominal bore.
189065mm nominal bore.
189150mm nominal bore.
189240mm nominal bore.
189332mm nominal bore.
189425mm nominal bore.
1895Providing and fixing gun metal non- return valve of approved quality (screwed end) : (horizontal)
189680mm nominal bore.
189765mm nominal bore.
189850mm nominal bore.
189940mm nominal bore.
190032mm nominal bore.
190125mm nominal bore.
1902Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design :
1903With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1904Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick,finished with a floating coat of neat cement complete as per standard design :
1905With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1906RAIN WATER HARVESTING & DRAINAGE SYSTEM
1907RECHARGE PITS
1908Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge.
1909In all kind of soil upto 1.5m depth
1910In all kind of soil upto 1.5m to 3.0m. depth
1911In all kind of soil upto 3.0m to 4.5m. depth
1912In all kind of soil upto 4.5 m to 6.0m. depth
1913Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors.
1914Class M-150 brick work in 1:4 cement coarse sand mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work.
1915Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement.
1916Suspended floors, roofs, landings, balconies and access platform.
1917Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
191812mm cement plaster on rough side of single or half brick wall mix
19191:3 (1 cement : 3 Coarse sand)
1920Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:
1921With 20x20mm square bar
1922Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
1923M.D. -10- Circular shape 500mm internal diameter
1924Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.
1925Drilling of 300mm dia bore hole manually.
1926Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
1927150 mm nominal size dia
1928Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for all leads& lifts, all complete as per direction of Engineer-in-charge.
1929Supplying, filling, spreading & leveling gravels of size range 5 mm to10 mm, in the recharge pit, over the existing layer of boulders, inrequired thickness, for all leads & lifts, all complete as per directionof Engineer-in-charge.
1930Supplying, filling, spreading & leveling coarse sand of size range 1.5mm to 2 mm in recharge pit, in required thickness over gravel layer,for all leads & lifts, all complete as per direction of Engineer -incharge.
1931Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading& sizes as per actual requirement, all complete as per direction ofEngineer-in-charge.
1932DESILTING CHAMBER
1933Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge.
1934In all kind of soil upto 1.5m depth
1935In all kind of soil upto 1.5m to 3.0m. depth
1936Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors.
1937Class M-150 brick work in 1:4 cement coarse sand mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work.
1938Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement.
1939Suspended floors, roofs, landings, balconies and access platform.
1940Providing & Fixing Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
194115mm cement plaster on rough side of single or half brick wall mix
19421:3 (1 cement : 3 Coarse sand)
1943Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:
1944With 20x20mm square bar
1945Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
1946M.D. -10- Circular shape 500mm internal diameter
1947DRAINAGE NETWORK
1948Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m.
1949up to 1.50 m depth
1950Pipes 80 mm to 300 mmdiameter
1951Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete.
1952150 mm.dia. RCCPipes
1953250 mm.dia. RCCPipes
1954Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design
1955150 mm. dia.
1956250 mm. dia.
1957Constructing brick masonry INSPECTION chamber 60x60x75 cm with bricks of class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI cover with frame LIGHT WEIGHT complete as perdesign. With FPS bricks
1958Constructing brick masonary open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design:
1959Drain 300 wide average.Depth 45 cm with R.C.C. slab
1960Drain 450 wide average.Depth 60 cm with R.C.C. slab
1961EXTERNAL SEWERAGE SYSTEM (SEPTIC TANK)
1962Size :- Length = 7.50 M. Width = 2.65M Total Depth =3.00M
1963Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge.
1964In all kind of soil upto 1.5m depth
1965In all kind of soil upto 1.5m to 3.0m. depth
1966In all kind of soil upto 3.0m to 4.5m. depth
1967Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size)
1968Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand)
1969Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement.
1970Suspended floors, roofs, landings, balconies and access platform.
1971P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
197212mm cement plaster on rough side of mix 1:3 (1 cement : 3 coarse sand)
1973Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars.
1974Providing and fixing C.I. tee at the inlet and outlet of septic tank.
1975Providing & fixing 75mm dia vent pipes.
1976Providing & fixing of 75mm dia cast iron terminal guard.
1977Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
1978M.D. -10- Circular shape 500mm internal diameter
1979M.D. -2.5- Circular shape 450mm internal diameter
1980Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.
1981With F.P.S. bricks
1982TUBE WELL
1983Drilling of 200 mm dia bore hole.
1984Supply of 125 mm dia MSpipe as per IS1239
1985Supply of 125 mm dia slotted MSpipe
1986Supply and fixing of nylon jali around the slotted pipes complete as required.
1987Providing and packing of coarse sand / pea gravel around the pipe.
1988Transport of boring tools other required equipements and installation at site.
1989Supply of submersible pump (3.7KW/5.0 HP) of make KSB (Cora) for 200 lit/min discharge at 50 meter head with control panel, support wire etc complete.
1990Providing 3 core PVC insulated submersible cable. (from pump panel to submersible pump)
1991Providing and fixing 65 mm dia. G.I. pipe complete with fittings and clamps including cutting and making good the wall etc. (from submersible pump to ground level)
1992Providing and fixing 65 mm dia. brass gate valve with CI wheel of approved quality.
1993Lowering of 125 mm dia MS pipe in bore hole including cutting,jointing etc complete.
1994Supply and fixing of tube well accessories i.e. well cap, clips, clamps, etc. to complete the job in all respect.
1995Fixing, testing and commissioning for erection and lowering of submersible pump, 65 mm dia GI column pipe, 3 core submersible copper cable upto the control panel, supporting clamps, cable clips, pressure gauge, connection line and all other accessories required for the proper completion of the work.
1996Testing and development of tube well.
1997Horticulture and Landscape
1998Supplying and stacking sludge at site including royalty and carriage up to 1 km (sludge measured in stacks will be reduced by 8% for payment).
1999Carrigae of sludge upto 5 K.M.
2000Supplying and stacking at site dump manure from approved source including carriage upto 1 km (manure measured instacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm
2001Carrigae of manure upto 5 K.M.
2002Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.
2003Spreading of sludge, dump manure or/and good earth in requiredthickness (cost of sludge dump manure or/and good earth to bepaid separately).
2004Digging holes in ordinary soil and refilling the same with theexcavated earth mixed with manure or sludge in the ratio of 2:1by volume (2 parts of stacked volume of earth after reduction by20% : 1 part of stacked volume of manure after reduction by 8%), flooding with water, dressing, including removal of rubbish and surplus earth, if any with all leads and lifts ( cost of manure, sludge or extra good earth if needed to be paid for separately).
2005Holes 0.9 m dia. and 0.90 m deep.
2006Providing & stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge.
2007Providing & stacking of Pinus longifolia (Pinus) of height 90-105 cm. in cement pots of size 35cm as per direction of the officer-in-charge.
2008Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately). With grass Turf.
2009Providing and fixing M.S. flat iron tree guard 60 cm dia and 2 m high, above ground consisting 4 nos 25 x 6 mm, 2.25 m long and 8 nos 25 x 3 mm 2 m long verticals M.S. flats, riveted to 3 nos 25 x 6 mm M.S. flat iron rings in two halves, fixing together at site with required six numbers of 8 mm dia. and 30 mm long bolts, including painting two coats with synthetic enamel paint of approved brand and manufacture over a coat of primer. One name plate of 1 mm thick M.S. sheet of size 250x100 mm shall be welded to the treeguard near the middle height and lettered CPWD / PWD/ any other approved name. The tree guard shall be suitably fixed to the ground by embedding four legs of tree guard in pits of suitable dia and to a depth of 25 cm, refilling the pits with soil and ramming, complete in all respect as per satisfaction and direction of Officer-in-charge.
2010Add for Ornamental trees, shrubs & planters
2011PVC Coatd Fencing
2012Fencing Rear Side (Details as per TS estimate)
2013Fencing Left/Right Side (Details as per TS estimate)
2014Development of Front Boundary Wall (AR- BW1) (55.07 RM)
2015Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
2016Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-lll) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
2017Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) [ M-20 ]
2018All works upto plinth level
2019Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
2020All works Above plinth level
2021Centering and shuttering including strutting, propping etc. and removal of form for
2022Foundations, footings, bases of columns, etc. for mass concrete
2023Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick
2024Columns, Pillars, Piers, Abutments, Posts and Struts
2025P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks.
2026Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
2027Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)
202815 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand
2029Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
2030Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
2031Providing, Suppling & fixing of cultural Terracotta tile mural work of 20mm thick inspired from the extraction of Ramayana and the Local Tangible context as per architect incharge.
2032Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
2033Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
2034Parking
2035Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. (DSR 2.8.1)
2036Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. (DSR 4.1.8)
2037Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.. (DSR 2.27)
2038M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work.(DSR 6.1.2)
203915mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand of 2.25 F.M. (DSR 13.5.1)
2040Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr10 sqm (DSR 13.48.1)
2041Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete (DSR 13.80)
2042Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on# 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick Jamunasand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge.[DSR 11.45]
2043Providing & fixing White/Colored River (Stone) Pebbles size of 1\" to 2\" dia in natural colour at site of work including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge. (Details as per TS Estimate)
2044Entrance Gate
2045Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
2046Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
2047Signages
2048A. THEMED INTERIOR & ART WORKS
2049Wall Panelling: Fabricating & fixing full height plywood panelling (overall thickness 62mm) consisting of 50mm x 25mm x 2mm GI sections approved Make framework with all necessary reinforcements required of GI, at spacing not exceeding 600mm x 1200 . Partition framework to be fixed to existing masonry walls. Rate to include providing and fixing of additional GI sections of approved size as per Architects drawings. Cost to include additional sections (horizontal & Vertical) as required for fixing of Digital Displays, Screens.,, Glass boards, and White boards as indicated by the Architect. Cost to also include the necessary provisions required to take Data & Electrical conduiting.
2050Boarding: Boarding with 12mm th Fire resistant pre laminated LDF Board LDF board
2051Cost to include an average projection of 600mm from true wall including creating slopes, curves in elevations as indicated in the drawings.
2052Cost to include providing of recess of upto 200 mm such as coves and niches, the shape shall be not measured seperately
2053Cost to include providing necessary BWP plywood backing up to 18mm for Digital displays as indicated in the drawing
2054Cost will be measured based on the board up area and not for frame works.
2055Approved Brands - 1. Frame : Jindal, apollo, sections or equivalent2. Plywood - Green ply, Kitply, Merino, archidply or equivalent3. Laminate– Merino, Greenlam or equivalent
2056RAISED PLATFORMProviding and fabricating 225mm Low Raised Platform made of GI/MS framework using 50mm x 50mm GI/MS sections Jindal Make framework with all necessary reinforcements required of MS/GI, at spacing not exceeding 600mm both ways ( horizontal & vertical ). Framework to be fixed to existing surface. Boarding made of 18mm BWP plywood fixed to MS/GI frame, including required joints & surface finish as indicated in the architect drawing. Cost to also include the necessary provisions required to take Data & Electrical conduiting.
2057GRAPHIC/CONTENT SIGNAGE BOARDVinyl print with Installation - Providing & Fixing Printed Vinyl Graphics on Punned or Levelled Surface of (3M or Equivalent) ,overPlywood /MDF or Laminate. Cost to include cleaningfor any stains, scffolding for height upto 8000mm from FFL as per design approved by ARchitect in chargeApproved Make - 3M, LG, Avery/Equivalent
2058Infographics design for the above vinyl prints:Design and development of all the infographics as per the museum design in Hindi & English languages make approved s per drawings directed as per Architect in-charge. 2D Illustration& Artwork & Interactive,MotionGraphics, 2DAnimations,Editing&Compositing, scripted with poetic flair and historic accuracy providingthegreatestcinematicexperience. Use of animated layers composited with archives, animated text, illustration, complementing the masking narration, ambience and music. Producing graphical contentofvernacularpressforinteractive LEDs. Producing well styled, contemporary themed,graphicalcontentwithexhaustive coverageofthe Mainpuri city\"s culturefor12 interactivescreensandaninteractivetable with10Mwidescreensoneachsides.All content to becompletein allaspects,as per design approved by Architect in charge
2059B. AV WORKS
2060PC for Interactive Kiosks Intel I5 PC/ 16GB Ram/ 512 GB SSD/ DvdR/ P4000 8Gb Gfx/ Win 10 ProApproved Makes: Dell/HP/Lenovo/Equivalent as approved by ARchitect in charge
206132\" Interactive display Approved Makes: LG/Panasonic/Samsung/Benq/Veiwsonic/Equivalent
2062HDMI Over Cat6/FOTransmitterUp to 2560x1600* @ 60 Hz or 4K (4096x2160) @ 30 Hz, UHD (3840x2160) @ 30 Hz, 4K/UHD @ 60 Hz with 4:2:0 chroma subsampling, HDMI 1.4, HDCP 2.3, Max Vide Data Rate 10.2 Gbps, support pixel clock of 300Mhz, accepts addition stereo audio, RS232, IR Signals.Approved Makes: Extron/Crestron/Lightware/Aten/Equivalent as approved by ARchitect in charge
2063SITC of necessary track lights/Spot liighting for all the infographics artefacts/ manuscript display Case, as per design. as approved by ARchitect in charge
2064Resting Areas for Tourist (Benches) {MR}
2065Providing & fixing ofred Sandstone/MS bench with Ornamentetion on armrest (size 1050mm length and 450mm and height 450 mm) including foundation & support with all necessary T&P etc all complete as per design of direction in engineer/ Architect in charge.
2066Urban Litter Bins(MR)
2067Providing & fixing of SS Dustbin size 487 x 399 x 1138 fixing on a foundation with base plate and wrapped with red sandstone from all sides of 75mm with all complete as per design of direction in engineer/ Architect in charge.
2068Directional & Informative Signages (MR)
2069Providing and fixing StandAlone Signage in Metal/stone/Corten steel of approved thickness with powder coated 10-12mm MS letters and illustration at desired locations with letters (in english, hindi and Braille)- etched, through cut, infilled or painted, also including the cost of design, fabrication and onsite installation with all the necessary accessories and equipments for fixing on any surface as per drawing and design approved from Architect in charge English: Helvetica Font with min. 36 size Hindi: Krutidev Fontwith min. 36 size
2070Signage-A
2071Signage-B
2072Signage-C
2073External Electrification
2074Supplying, Installation and commissioning of AMF start silent type62.5 KVA DG set comprising of suitable BHPdiesel engine directly coupledto 3 phase 50 Hz 415 V alternator of 160 KVA rating at 0.8 power factor mounted on a common base frame, complete in all respects with all required safety devices, fittings, batteries, accessories, filters, residential type silencer, control panel, inbuilt diesel oil MS tank of 990 ltrs. capacity made of 2mm thick M.S. sheet complete with M.S. fuel piping, G.M. gate valves, supports, control cable between generating set and control panel, exhaust piping with asbestos roping, antivibration mounting pads, first filling of lubricant oil totally enclosed in air tight, dust proof, weather proof, powder coated cubical type, sound proof as per CPCB norms acoustic enclosure made of 2mm thick CRCA sheet with with heavy duty doors, lockable arrangement, sound proof insulation with high density rock/mineral polymer/fibre cloth and perforated CRCA sheets, suitable to reduce the sound level upto 75dba approx. at a distance of 1 mtrs. as per CPCB norms
2075AMF Panel Incoming-160 Amps FP MCCB of 36KA breaking capacity and contactor same rating
2076Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB\"s (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only.
2077MAIN FEEDER PANEL
2078Incoming :
20792 No 160 Amp. 4P MCCB of 25KA (Ics=Icu)Breaking Capacity
2080Metering :
20812 Set of CT\"s one of 160/ 5Amp ratio for Multifunction Meter
20822 Set of Phase Indication Lamp.
2083Bus Bar :
2084One (1) No. 200 Amp. FP aluminimum bus bar of suitable length.
2085Outgoing :
2086Phase indication lamps on each outgoing to be provided.
2087100 Amps FP MCB - 2 No
208863 Amps FP MCB - 2 No
208925 Amps DP MCB - 3 No
209016 Amps DP MCB - 6 No
2091SPARE & SPACE- 1 No
2092Panel described as above
2093FEEDER PILLAR
20941 No 63 Amp. 4P MCCB of 25KA (Ics=Icu)Breaking Capacity
2095Metering :
20961 Set of Phase Indication Lamp.
2097Bus Bar :
2098One (1) No. 100 Amp. FP aluminimum bus bar of suitable length.
2099Outgoing :
2100Phase indication lamps on each outgoing to be provided.
210140 Amps DP MCB - 3 No
210225 Amps DP MCB - 1 No
210316 Amps DP MCB - 8 No
2104SPARE & SPACE- 1 No
2105Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each
2106Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
2107Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required.
2108Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
2109Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
2110Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
2111Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
2112Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
2113Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.
2114Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
2115Up to 35 sq.mm.
2116Above 35 sq.mm. and up to 95 sq.mm.
2117Above 95 sq.mm. and upto 185 sq.mm.
2118Above 185 sq.mm. and up to 400 sq.mm.
2119Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, rotective covering and refilling the trench etc as required
2120Up to 35 sq.mm.
2121Above 35 sq.mm. and up to 95 sq.mm.
2122Above 95 sq.mm. and upto 185 sq.mm.
2123Above 185 sq.mm. and up to 400 sq.mm.
2124Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
2125Up to 35 sq.mm.
2126Above 35 sq.mm. and up to 95 sq.mm.
2127Above 95 sq.mm. and upto 185 sq.mm.
2128Above 185 sq.mm. and up to 400 sq.mm.
2129Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
2130Up to 35 sq.mm.
2131Above 35 sq.mm. and up to 95 sq.mm.
2132Above 95 sq.mm. and upto 185 sq.mm.
2133Above 185 sq.mm. and up to 400 sq.mm.
2134Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required
2135Up to 35 sq.mm.
2136Above 35 sq.mm. and up to 95 sq.mm.
2137Above 95 sq.mm. and upto 185 sq.mm.
2138Above 185 sq.mm. and up to 400 sq.mm.
2139Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required
2140Upto 35 sq. mm (clamped with 1mm thick saddle
2141Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp
2142Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp
2143Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
2144Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
2145Upto 35 sq. mm (clamped with 1mm thick saddle)
2146Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
2147Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
2148Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
2149Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment
21503.5 x 400 sq.mm.
21513.5 x 300 sq.mm.
21523.5 x 240 sq.mm.
21533.5 x 185 sq.mm
21543.5 x 150 sq.mm
21553.5 x 120 sq.mm
21563.5 x 95 sq.mm
21573.5 x 70 sq.mm
21583.5 x 50 sq.mm
21593.5 x 35 sq.mm
21603.5 x 25 sq.mm.
21614 x 16 sq.mm
21624 x 10 sq.mm
21633 x 6 sq.mm,
21642 x 16 sq.mm,
21652 x 10 sq.mm,
21662 x 6 sq.mm,
2167Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.
21682 X 6 sq. mm (19mm)
21692 X 10 sq. mm (19mm)
21702 X 16 sq. mm (22mm)
21713½ X 25 sq. mm (28mm)
21723½ X 35 sq. mm (32mm)
21733½ X 50 sq. mm (35mm)
21743½ X 70 sq. mm (38mm)
21753½ X 95 sq. mm (45mm)
21763½ X 120 sq. mm (45mm)
21773½ X 150 sq. mm (50mm)
21783½ X 185 sq. mm (57mm)
21793½ X 225 sq. mm (62mm)
21803½ X 240 sq. mm (62mm)
21813½ X 300 sq. mm (70mm)
21823½ X 400 sq. mm (82mm)
21834 X 10 sq. mm (25mm)
21844 X 16 sq. mm (28mm)
2185Providing, laying and fixing following dia G.I. pipe (mediumclass) in ground complete with G.I. fittings including trenching(75 cm deep)and re-filling etc as required
2186100 mm dia
2187Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
2188100mm dia
2189150 mm dia
2190250 mm dia
2191300 mm dia
2192Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
219390 mm dia (OD-90 mm & ID-76 mm nominal)
2194ProvidingandfixingHT danger notice plate 250 mm x 200 mm made of mild steel at least 2mmthick &vitreousenamelledwhiteon bothsides and withinscription insignalred colouronfront side as required.
2195Supplying andFixing of Fire buckets, round bottom made of G.I. Sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-charge.
2196Supplying and Laying of Rubber mat 1000 mm. Wide to withstand 11 KV dielectric strength as per latest IS 15652-2006 etc. as reqd.
2197Supply and fixing of fire extinguishers, ABC Type 9.00 kg. capacity(ISI Marked IS : 15683 & TAC approved)complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work.
2198Supply and fixing of CO2 typefire extinguishers, 4.50 kg. capacity(ISI Marked IS : 2878 & TAC approved)complete with initial charges and wall bracket, along with supply of all materials and labour for proper completion of work.
2199Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
2200With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5
2201Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2202Double pole
2203S & F cast Step light complete as required. Step Light31435, Anthracite grey, Aluminium, 104x104x35,LED Integrated3W, 50lm/3000K, Make Philips or Equivalent
2204S & F Spike light complete as required.
2205S & F cast aluminium 4 mtr. Pole for post top light complete as required Town Glow Post Top Town Glow is a contemporary designer IP66/IK10 Post Top lantern with symmetric light distribution BGP300 LED40 757 PSU PC IN SI hsn code 9405 make Philips or euqivalent
2206Supply and fixingUNILinear Flex is IP68 cove lighting with reliable performance and excellently waterproof, anti-dust LED strips with professional design for vivid colors.BGC301 400LM 3000K L5000 9405
2207Supply and fixing of decorative 8 to 16 Watt LED bollard luminaire with driver set confirming to IP 65 protection complete in all respect
2208Supply and fixing of LED Gate light fitting having die cast aluminium body and diffuser with driver set suitable for 6 watt to 10 watt. Confirming to IP 54 and above protection complete in all respect.
2209Supply and fixing Superior illumination Classy anthracite finishPremium aluminium material Optimum performanceHighlight the outdoors IP65 fixture ideal for outdoor & wet areasupdown lighterModel No.-31450Colour-AnthraciteMaterial-AluminiumDimensions (mm)-159x99x66Lamp Base-LED IntegratedWattage-10WLumen/CCT-670lm/3000KMAKE -PHILIPS or equivelant
2210Supply and fixingUNIIn-Ground: Ground BurialCompact and robust design with diecast aluminium housingand stainless trim, IP68 waterproof connectors.11:50 BBP341 LED540/WW 6W 20D 100-240VMAKE -PHILIPS or equivelant
2211SITC of 15w integrated Solar All in one suitable at height of 5mtr mounting arrangement. pole with minimum 2250 lumen , luminous flux with min.>150lm/w luminous efficacy having power of PV module (Wp) 40, Panel Type Mono Crystalline, Panel Dimensions not more than (mm) 775 (L) x 340 (W) x 60 (H), Battery Capacity max. 18 (Ah), Battery Rated Voltage 12.8(V), Battery type LiFePO4, having BMS protection Battery Management System ,having min. Battery Back up to 2days (24 hours) (Autonomy mode),MPPT charge controller type, Efficacy>90%, having facility of Charging Indicator (Green blinking),Low Battery Indicator (Red blinking),Error Indicator (Both blinking),For the better battery life having Over Charge Protection, Deep Discharge Protection, Battery reverse polarity protection ,Load Short circuit protection, Load Open circuit protection, Reverse polarity protection for Panel, Over temperature protection. Motion sensor detection facility with Long Distance Detection 12m.CCT-5500-6000k, Make-Panasonic, Philips or equivalent
2212Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.
22131 output per phase and suitable for single phase supply
2214Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
2215Above 6.5 metre and upto 8.0 metre
2216Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required
221732 mm dia
2218GST Extra As per Applicable

AI Tender Summary

OUR REF NO 43919317
AUTHORITY Government Departments
TENDER VALUE 3.70 Crore
LAST DATE 04-07-2024
Authority
Authority Name Uttar Pradesh Projects Corporation Limited
Work Description Tender For Development Of Tourism Amenities At Sohagi Barwa Wildlife Sanctuary, Maharajganj
Basic Detail
Tender No 10/GM-3/UPPCL/2024-25 DATED 11.06.2024
Bidding Type Tender
Location
City mahrajganj
State Uttar Pradesh
Key Dates
Publish Date 27 Jun 2024
Submission Date 04 Jul 2024
Open Date 04 Jul 2024
Finance
Tender Value 3.70 Crore
Tender Fee 17700
EMD 7.40 Lakhs
Exemption Not Available
Document List
e4ff69bb-159e-4009-acf9-8cffa8d24653.html
BID_DOC10.pdf
BOQ_1613034.xls
Corrig_10.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 27, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 04, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 04, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

e4ff69bb-159e-4009-acf9-8cffa8d24653.html

pdf

BID_DOC10.pdf

xls

BOQ_1613034.xls

pdf

Corrig_10.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders