Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | A) INTERIOR |
| 2 | ITEM No. 1 :- SITC OF : Wall Panel MOC : SS 304 (Stainless Steel - Grade 304): SS 304 Sheet thickness - 1 mm, PPGI sheet thickness 0.8 mm Standard panel dimensions: 1180*2400mm with an overall thickness of80 mm Standard wall & ceiling panels are a composite construction of double skins Panel Thickness : 50mm with 45 Kg/m3 PUF insulation Panels Joints - The panel joints are sealed by silicone for a perfectly flush finish |
| 3 | ITEM No. 2 :- SITC OF : Ceiling panels Panel MOC : SS 304 (Stainless Steel -Grade 304): SS 304 Sheet thickness - 1 mm, PPGI sheet thickness 0.8 mm Standard panel dimensions: 1180*2400mm with an overall thickness of 50 mM Standard wall & ceiling panels are a composite construction of double skins Panel Thickness : 50 mm with 45 Kg/m3 PUF insulation Panels Joints - The panel joints are sealed by silicone for a perfectly flush finish. |
| 4 | ITEM No. 3 :- SITC OF : Aluminium Coving R-50 with Aluminum Backing (Metallic Powder Coated): Al Coving powder coating of R60 is being used to fill the gap between wall panel to false ceiling and also between wall panel to wall panel at corners. |
| 5 | ITEM No. 4 :- Modular Cleanroom Profile Panels for Ceiling Free-standing structure with PUF insulated Panels.• Composite construction ofdouble skins – Both sides PPGI with a protective film thick over a GI profileframework along the periphery & GI inter-locking section, with base runner.• The panel joints are sealed by silicone for a perfectly flush finish.• The panel core will consist of rigid polyurethane foam, which has been injected under high pressure. |
| 6 | ITEM No. 5 :- SITC OF :Antistatic Conductive Vinyl Flooring: Flooring in operation theatre should be seamless with perfectly curved flush-coving, resistant to mechanical stress and dynamic loads and having protectioncharacteristic (Conductive), Vinyl Specifications - Thickness @ 2mm, Washable vinyl in Sheet form, Flooring should be laid on sell leveling compound, Vinyl properties - Complies to EN 433, EN 649. EN 1815, EN 1081 standards TVOC as per AgBB/ DIBt Certifications, ISO 16000-6 It should have antibacterial, antifungal properties |
| 7 | ITEM No. 6 :- SITC OF :Self Levelling for above Flooring: Epoxy based self-levelling - 2 to 3mm for laying the Vinyl flooring |
| 8 | ITEM No. 7 :- SITC OF : HEPA Plenum withSS 304 Diffuser grill & Terminal HEPA Filters ForOphthalmicOT: Plenum designed as per NABH standards1.Plenum MOC : Stainless steel 304,2.Plenum Size : 2620mm x2620mm [8 ft x 8 ft]3.Plenum Diffuser Grill: The high quality S.S.304 Diffuser grill for securing unidirectionalair flow according to EN ISO 14644. SS 304 grill designed to deliver uniform air velocityacross the entire HEPA plenum to maintain uniform air displacement on the OT table.4.Central Opening: Plenum design with opening for OT lamp nor more than 300*300 withcover plate5.Filter housing and pressure chamber : MOC stainless steel 304 matt polish, thickness1.2 mm.6.Filter section:- Mini-pleat (H14) grade HEPA Filters placed as Terminal Filters- Filters to be D.O.P. tested to remove particles up to 0.3.micron.- Filters to be D.O.P. tested to remove particles up to 0.3.micron.7. Total HEPA Filter Area : 32 sft. resp.8.Plenum mounted Periphery Lights: Provision for LED light box on all 4 sides Box size200mmx2000mm (extra over the LAP Plenum size Plenum box mounted LED tube light of18 watt – 6nos, total |
| 9 | ITEM No. 8 :- SITC OF :Hermatically SealedDouble Swing Door MOC : SS 304 Door Size : 1500mm x2100mm: MOC - SS 304 / 0.8 mm Sheet for Door Leaf Sheet MOC - SS 304 / 1.2mm thick for Door Frame Doors are designed to fit flush into the wall panel system on both sides and are supplied in different dimensions. Doors are fabricated from GI P. Coated Shutter has sheet thickness of 0.8mm and the frame of 1.2mm. Standard 50 mm panel has frame width of 50 mm and shutter width of 45mm. Doors are available in various sizes as per the requirement of the client. The following accessories are a part of the door: Shutter Thickness: 45 mm thick Stainless steel hinges Stainless Steel \"D\" type of handles on pull side Stainless steel push plates on push side. Standard arm door closure (TS-68) View panel along with self adhesive tape and silicon sealant Both side key operated locking arrangement Automatic |
| 10 | ITEM No. 9 :- Supply & Installation of Cascade Pressure Stabilizer having multi 304 graded stainless steel blades to control room air pressure, The blade pivot mechanism shall incorporate nylon bushes and stainless steel pins to ensure maintenance free operation. |
| 11 | ITEM No. 10 :- Supply & Installation of 2 Plate LED DimmableX-Ray Viewing Screen ( Dimming range 3 - 100% ), range of 3- 100 %,, complete with all accessories etc.(Size 950x 648mm) |
| 12 | ITEM No. 11 :- Supply & Installation of Operatingwriting List Board(Magnetic) of size 948mm X 648mm complete with all accessories. |
| 13 | ITEM No. 12 :- SITC OF :Peripheral Lights / OTLuminaries : LEDType: Technical specifications:1. Recess mounted IP65 Protocol2. Non-hygroscopic peripheral lights.3.Size : 2ft x 2ft 4 . Sitable watts for required proper Illumination for Operation |
| 14 | ITEM No. 13 :- SITC OF : LAF- SYSTEM CONTROL INTERFACE (3 Panel System):Theater Control Interface(TCI)With inside MOT controlling: Designed to have maximum controls within the theatre, will be located on a membrane type control panel mounted in the theatre wall. It compromises1. Digital Real time clock2.Digital Laps timer3.Set of Temperature controller, Humidity controller4.OT Light control5.Medical Gas Alarm6.Hands free telephone7.HEPA pressure monitor (Analog &/Or Digital) The panel will incorporate all the necessary controls for the correct operation and monitoring of the equipment and services with following feature -( One Pressure monitoring required out side every OT) |
| 15 | ITEM No. 14 :- SITC OF :Storage Unit MOC : SS 304 Storage Size : 1200 x 1800 x 250 mm: Internal Storage embedded in the wall panels, flushed inside the wall Storage Shelves - Minimum 3 & Maximum 5 racks, The MOC for the rack is SS 304 Doors - PUF insulated Double door with large glass view panel. |
| 16 | B) EQUIPMENTS |
| 17 | ITEM No. 15 :- Pass/Hatch Box :Having size in accordance to the requirement should not be lesser than 600x600mm made of stainless steel grade 304 having door interlocking , UV light electronic controls. |
| 18 | ITEM No. 16 :- Supply & Installation of Operating Table: Operating Table of size 1985mm x 580/530mm maximum height 1080mm, minimum height 780mm side tilt right and left 20 degree,electrically operated. |
| 19 | ITEM No. 17 :- Supply, installation, Testing and Commissioning of Electrical suction Machine. It should be capable of displacing at least 40 liters / min. and creating negative pressure of Upto 700 mm of Hg. This pressure should be regulated through a control knob. It should be powered by ¼ HP Crompton or equivalent motor. The machine should be mounted on antistatic castors. There should be a large size (at least 10 cm ) Bourden type gauge to show the pressure on front panel. There should be two interconnected polycarbonate (autoclavable) jars of 2-liter capacity withself -sealing stopper with integrated overflow protection device. The pump should be of concealed oil immersion type. It should be a medical grade machine with noise level of less than 50 dB. Electrical rating of 220/230 V, 50 Hz & power rating of < 5 Amp. The motor should have an automatic lubrication system. The on/off switch should be a spark-containing switch. It should be supplied complete with two jars, electricalcord and 10-mm dia. Non-collapsible tubing; ready for use. |
| 20 | ITEM No. 18 :-Sterile Air-Shower? MOC – 1mm SS 304, ? Internal Dimensions – 800(W) x 800(D) x 1950(H)HEPA Filter HEPA Filtered Air (0.3 Micron, 99.97% Efficiency)Pre -Filter 5 micron Aluminium, 95% EfficiencyMotor Blower Suitable motor blower assembly EBM MOTORDoor Stainless steel double walled door with polycarbonate / Toughenedsandwiched view panels.Door Interlocking stainless steel Electromagnetic interlocking systemDoor Opening Straight entry and straight exit with 90° door opening.Switches ON/OFF switches for door entry and exit. |
| 21 | ITEM No. 19 :- Supply ofless maintenance Syringe Pump Easy to use having Rugged design & Accept all standard injectors of 10 ml, 20 ml & 50 ml, diagnose and display the injector\"s size automatically also has Alarm function when there is malfunction or operation error, and meanwhile the machine stops running automatically |
| 22 | ITEM No. 20 :- Supply, installation, Testing and Commissioning of Shadowless Operating Light: Shadowless ceiling mounted Double Dome LED Operating Lightwith a intensity of 160000lux advance feature of three different modes of surgery ,Endo mode,Surface node and Deep cavity mode, having arm with 360deg movement color temprature 4300 spot dia. 150-350 mm,color rendering index(Ra)>96 |
| 23 | ITEM No. 21 :- Supply & Installation of Single Arm aneasthesia pendanthaving a arm length of 700mm withweight carrying capacity of more than 100Kg, 8 electrical sockets 5/15 ampere & Data Point, one monitor shelf, one sliding tray and 6 nos.of gas outletsO2x2,N2Ox1,MA4x1,and Vac x 2 |
| 24 | ITEM No. 22 :- Supply & Installation of Double Arm Surgeonpendanthaving a one arm of length 700mm and other of 600mm weight carrying capacity of more than 100Kg, 8 electrical sockets 5/15 ampere & Data Point, one monitor shelf, one sliding tray and 6 nos.of gas outletsO2x2,,MA4x1,SA7x1 and Vac x 2 |
| 25 | ITEM No. 23 :- SITC OF : Surgical Scrub Automatic type MOC:SS 304 Size 1500*1000*600 mm: 1. Capacity - Two (2) Bay Scrub Sink2.Configuration - floor mounted3.Operations - Manual / Mechanical through Floor switch &/Or Elbow action4. Automatic sensor based operations.5. Hardware - Mixture valve (1 No.) and Solenoid valves (2 Nos.)6.The scrub sink is provided with front access panel for ease of maintenance & repair7. Automatic Operation Specifications: - Infrared Photo sensor Digital Timer with userdefined time interval of 1,3,5, & 10 min8.MOC : Stainless Steel Grade 304, Anti-splash metal body construction polished finish9. Mixer arrangement for hot and cold water, Hot water source at Client end |
| 26 | ITEM No. 24 :- Supply, Installation, testing and commissioning of SS Shelving Units made from Frame work of CRCA steel tubes. Epoxy powder coated finish. |
| 27 | ITEM No. 25 :- Supply, Installation, testing and commissioning of SS Medicine Trolley with 4 drawer, having 2 drawers under the each S. S. shelve. made from Frame work of CRCA steel tubes mounted on 10 cms castors . Epoxy powder coated finish.Size: 760 x 460 810mm |
| 28 | ITEM No. 26 :- Supply of Stainless Steel Top Revolving Stool for Patient, S.S.top through screw, pre treated and epoxy powder coated, 18 to 27 adjustable heights & Foot ring supports |
| 29 | C) MEDICAL GS PIPING SYSTEM |
| 30 | ITEM No. 27 :- Supply, Installation, testing and commissioning of Copper piping of 28mm size for distribution and supply of O2, vacuum & medical gas to OT Rooms in the hopsital. The Copper pipes shall be solid drawn, seamless, deoxidised, nonarsenical, halfhard, tempered and degreased material conforming to BS-6017/1981, Table- 2(Cu-DHP) and manufactured as per BS- 2871/1971PartI, Table- X. The Copper pipe shall be supplied with test certificate and installed as per HTM-22 of UK specifications with utmostclenliness. After installation the pipes shall be painted with 2- coats of synthetic enamel paint and colour codification as per IS- 2379 of 1963. The piping shall be complete with all fittings conforming to BS- 864 and as perspecifications. |
| 31 | ITEM No. 28 :- Supply, Installation, testing and commissioning of Copper piping of 22mm size for distribution and supply of O2, vacuum & medical gas to OT Rooms in the hopsital. The Copper pipes shall be solid drawn, seamless, deoxidised, nonarsenical, halfhard, tempered and degreased material conforming to BS-6017/1981, Table- 2(Cu-DHP) and manufactured as per BS- 2871/1971PartI, Table- X. The Copper pipe shall be supplied with test certificate and installed as per HTM-22 of UK specifications with utmostclenliness. After installation the pipes shall be painted with 2- coats of synthetic enamel paint and colour codification as per IS- 2379 of 1963. The piping shall be complete with all fittings conforming to BS- 864 and as perspecifications. |
| 32 | ITEM No. 29 :- Supply, Installation, testing and commissioning of Copper piping of 15mm size for distribution and supply of O2, vacuum & medical gas to OT Rooms in the hopsital. The Copper pipes shall be solid drawn, seamless, deoxidised, nonarsenical, halfhard, tempered and degreased material conforming to BS-6017/1981, Table- 2(Cu-DHP) and manufactured as per BS- 2871/1971PartI, Table- X. The Copper pipe shall be supplied with test certificate and installed as per HTM-22 of UK specifications with utmostclenliness. After installation the pipes shall be painted with 2- coats of synthetic enamel paint and colour codification as per IS- 2379 of 1963. The piping shall be complete with all fittings conforming to BS- 864 and as perspecifications.3-2-27(Ref-2022/23 CSR)Pag No46 |
| 33 | ITEM No. 30 :- Supply, Installation, testing and commissioning of Copper piping of 12mm size for distribution and supply of O2, vacuum & medical gas to OT Rooms in the hopsital. The Copper pipes shall be solid drawn, seamless, deoxidised, nonarsenical, halfhard, tempered and degreased material conforming to BS-6017/1981, Table- 2(Cu-DHP) and manufactured as per BS- 2871/1971PartI, Table- X. The Copper pipe shall be supplied with test certificate and installed as per HTM-22 of UK specifications with utmostclenliness. After installation the pipes shall be painted with 2- coats of synthetic enamel paint and colour codification as per IS- 2379 of 1963. The piping shall be complete with all fittings conforming to BS- 864 and as perspecifications. |
| 34 | ITEM No. 31 :- Supply, Installation, testing and commissioning of Isolation Valves of 28mm size suitable for the pipe dia. The valves shall be non- lubricated type, stainless hard chrome brass with PTFE seat having opening by quarter turn of handly. The valves shall be pneumatically tested and degreased for medical gas service complete as per specifications |
| 35 | ITEM No. 32 :- Supply, Installation, testing and commissioning of Isolation Valves of 22mm size suitable for the pipe dia. The valves shall be non- lubricated type, stainless hard chrome brass with PTFE seat having opening by quarter turn of handly. The valves shall be pneumatically tested and degreased for medical gas service complete as per specifications |
| 36 | ITEM No. 33 :- Supply, Installation, testing and commissioning of Isolation Valves of 15mm size suitable for the pipe dia. The valves shall be non- lubricated type, stainless hard chrome brass with PTFE seat having opening by quarter turn of handly. The valves shall be pneumatically tested and degreased for medical gas service complete as per specifications |
| 37 | ITEM No. 34 :- Supply, Installation, testing and commissioning of Flexible Medical gas hoses used to provide a safe transferring low pressure medical gases ( Oxygen, Medical Air (MA4 and MA7), Nitrous Oxide and Vacuum ) 3mtr length with a connector crimped at either end complete as per specification. |
| 38 | ITEM No. 35 :- Supply, Installation, testing and commissioning of Area Alarms (4 Services) for OT shall be complete with pressure sensors, indications, alarmsetc. Andwith all accessories as per specifications. |
| 39 | ITEM No. 36 :- Supply, Installation, testing and commissioning of Valve Box (4 Services) complete with all accessories as required as per specifications |
| 40 | ITEM No. 37 :- Supply, Installation, testing and commissioning of Oxygen Flow meter with Humidifier (0- 15ltrs. /min) with adapter, tubing etc. The humidifier bottle shall be made of unbreakable & reusable polycarbonate material and autoclavable at 134 deg. C. The oxygen flow meter with humidifier shall be complete with all the required accessories and shall be complete as per specifications |
| 41 | ITEM No. 38 :- Supply, Installation, testing and commissioning of Oxygen Manifold: 4+4 Cylinder Oxygen Manifold should be suitable to withstand a pressure of 140 Kg/Cm2 and above along with 2 nos high pressure copper annealed tail pipes with end Brass adapter & NRV suitable for Cylinders and manifold. The manifold should be tested (hydraulically) (Note: Cylinder is not included) |
| 42 | ITEM No. 39 :- Supply, Installation, testing and commissioning of N2O Manifold: 4+4 Cylinder N2O Manifold should be suitable to withstand a pressure of 140 Kg/Cm2 and above along with 2 nos high pressure copper annealed tail pipes with end Brass adapter & NRV suitable for Cylinders and manifold. The manifold should be tested (hydraulically) (Note: Cylinder is not included) |
| 43 | ITEM No. 40 :- Supply, Installation, testing and commissioning of gasses terminal outlet box with Adapter complete as per specification. (O2 x 1,Air4 x 1, Vac x 1) |
| 44 | ITEM No. 41 :- Supply, Installation, testing and commissioning of gasses terminal outlet box with Adapter complete as per specification. (O2 x 2, N2O x 1, Air4 x 1, Vac x 1) |
| 45 | ITEM No. 42 :- Providing Factory fabricated cu- out in Wall & Ceiling panels for Electrical fittings & accessories. |
| 46 | D) AIR CONDITIONING SYSTEM |
| 47 | ITEM No. 43 :- BIO AIR HANDLING UNITS FOR OPERATION THEATRES The air moving capacities at high speed shall be as follows: 3800CFM @160SP, 11.00TR Supply ,installation,testing and commisioning of sectionalised constructtion double skin (46 mm thick) draw thru type Air handling units for Operation theatres as per specifications. AHU shall comprise of the following sections , all with thermal break profile.i.Filter Sections consisting of prefilter & microvee Filtersii. Fan section with airfoil blower, blower motor, direct drive, volume control damper and duct flexible connection.iii.4-6 row deep copper tube dx cooling coil iv. UVC Emitter system as per specifications along with power / control wiring and aluminium supporting structure.vi.Electric Heating for humidity control.viiDischarge plenum sectionviii. Mixing Box comprising of damper & filter section.Coil shall be selected for maximum air velocity of 500 ft/minute & face velocity across pre-filters at 500 ft/minute. The motor selected shall be energy efficient having efficiency (Class I) at full load ranging between 82.5% to 92% in accordance with motor rating as per specification.Fan motor assembly (as whole) shall be statically and dynamically balanced. Motors shall have Variable Frequency Drive compatible with localised BAS.It shall be operated through 0-10V / 4-20 mA signal from localised DDCsuitable for 415 ± 10% volts, 50 Hz, 3 phase AC supply. Vibration isolation shall be as per specifications and as shown on the drawings.The AHU shall be capable of delivering external static pressure of minimum 150 mmwg. Internal motorized damper shall be provided for exhuast Air / Return Air and Fresh Air. These damper shall receive 0 - 10V / 4 - 20 mA signal from BAS. |
| 48 | The quoted price shall also include VCD, at outlet & inlet, duct flexible connection at outlet, inlet & exhaust, pressure differential indicator (Magneholic gauge) across Fine filters. Price shall also be inclusive of all components described above to make unit complte in all respects. Inner skin of panels & all parts which comes with air contact shall be 22 G. with green gasR407c/R410c. The system used is briefly explained as 2 nos 5.5 TR.Air Cooled Condensing unit with scroll compressors would be connected to 1 no.3800 CFM Air Handling unit having 1 nos Dx coil. Each Dx coil would have 2 circuits each circuits cannection to 1 nos 5.5 TR. ODU. the coil shall be 4-6 rows deep with individual distributors. the quote price shall asloinculde the necessaryexpansion valve filter drier, hand shut off valveandSight glass connections, etc complete as per specifications |
| 49 | ITEM No. 44 :- SITC OF : Air Conditioning ODUCapacity (11TR): System Design Parameters :Temperature 20 +-2°C & RH @ 55 +-5% Low RH for ensuring infection-free sterileenvironment in the OT Outdoor Unit (ODU):- Microprocessor based air-cooled units with scroll compressors- Power : 3 phase to minimize power consumption. Configuration : 2 nos of outdoor unit.- Rectification scanner details should indicate healthy supply, High/low Voltage, Singlephasing or voltage unbalanced, Reverence phase sequence.11 TR (5.5 r x 2) For majorOT |
| 50 | ITEM No. 45 :- BIO AIR HANDLING UNITS FOR MALE ICU WARDThe air moving capacities at high speed shall be as follows: 6000CFM @100SP, 16.50TR Supply ,installation,testing and commisioning of sectionalised constructtion double skin (46 mm thick) draw thru type Air handling units for Operation theatres as per specifications. AHU shall comprise of the following sections , all with thermal break profile.i.Filter Sections consisting of prefilter & microvee Filtersii. Fan section with airfoil blower, blower motor, direct drive, volume control damper and duct flexible connection.iii.4-6 row deep copper tube dx cooling coil iv. UVC Emitter system as per specifications along with power / control wiring and aluminium supporting structure.vi.Electric Heating for humidity control.viiDischarge plenum sectionviii. Mixing Box comprising of damper & filter section.Coil shall be selected for maximum air velocity of 500 ft/minute & face velocity across pre-filters at 500 ft/minute. The motor selected shall be energy efficient having efficiency (Class I) at full load ranging between 82.5% to 92% in accordance with motor rating as per specification.Fan motor assembly (as whole) shall be statically and dynamically balanced. Motors shall have Variable Frequency Drive compatible with localised BAS.It shall be operated through 0-10V / 4-20 mA signal from localised DDCsuitable for 415 ± 10% volts, 50 Hz, 3 phase AC supply. Vibration isolation shall be as per specifications and as shown on the drawings.The AHU shall be capable of delivering external static pressure of minimum 150 mmwg. Internal motorized damper shall be provided for exhuast Air / Return Air and Fresh Air. These damper shall receive 0 - 10V / 4 - 20 mA signal from BAS. |
| 51 | The quoted price shall also include VCD, at outlet & inlet, duct flexible connection at outlet, inlet & exhaust, pressure differential indicator (Magneholic gauge) across Fine filters. Price shall also be inclusive of all components described above to make unit complte in all respects. Inner skin of panels & all parts which comes with air contact shall be 22 G. with green gasR407c/R410c. The system used is briefly explained as 3 nos 5.5 TR.Air Cooled Condensing unit with scroll compressors would be connected to 1 no.6000 CFM Air Handling unit having 1 nos Dx coil. Each Dx coil would have 2 circuits each circuits cannection to 1 nos 5.5 TR. ODU. the coil shall be 4-6 rows deep with individual distributors. the quote price shall asloinculde the necessaryexpansion valve filter drier, hand shut off valveandSight glass connections, etc complete as per specifications |
| 52 | ITEM No. 46 :- SITC OF : Air Conditioning ODUCapacity (16.50 TR): System Design Parameters :Temperature 20 +-2°C & RH @ 55 +-5% Low RH for ensuring infection-free sterileenvironment in the OT Outdoor Unit (ODU):- Microprocessor based air-cooled units with scroll compressors- Power : 3 phase to minimize power consumption. Configuration : 3 nos of outdoor unit.- Rectification scanner details should indicate healthy supply, High/low Voltage, Singlephasing or voltage unbalanced, Reverence phase sequence.11 TR (5.5 r x 3) For majorOT |
| 53 | ITEM No. 47 :- Supplying, installing, testing and commissioning split type variable speed inverter technology room Airconditioning unit 1 TR having ISEER minimum 4.50 suitable to operate on capacity 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall / floor mounting type complete with refrigerant R410A/R32 and copper condenser at position. specification no. APAC /SAC3-2-11(Ref-2022/23 CSR) Pg No 43 |
| 54 | ITEM No. 48 :- Supplying, installing, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity having ISEER minimum 4.50 suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floormounting type complete with Refrigerants R410 A /R32 and copper condenser at position. specification no. APAC/SAC 3-2-12(Ref-2022/23 CSR) Pg No 44 |
| 55 | ITEM No. 49 :- Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. |
| 56 | ITEM No. 50 :- Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line / suction line supply and returnpiping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such asbends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping forprotection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. |
| 57 | ITEM No. 51 :- Supplying & erecting soft drawn copper pipe suitable for refrigeration system having 22 SWG thickness and inner dia / size 22 mm complete. |
| 58 | ITEM No. 52 :- Supplying & erecting soft drawn copper pipe suitable for refrigeration system having 22 SWG thickness and inner dia / size 12 mm complete. |
| 59 | ITEM No. 53 :- Supplying & erecting soft drawn copper pipe suitable for refrigeration system having 22 SWG thickness and inner dia / size 16 mm complete. |
| 60 | ITEM No. 54 :- Supply and installation of theU PVC type drain piping of 20 mm dia. with U trap with sadling and proper clamping to end connect at main drain line. |
| 61 | ITEM No. 55 :- Supply and installation of theU PVC type drain piping of 32 mm dia. with U trap with sadling and proper clamping to end connect at main drain line. 1-2-5(Ref-2022/23 CSR) Pg No 4 |
| 62 | ITEM No. 56 :- Supplying and erecting circular flexible / rigid PVC pipe duct of size 50 mm dia, 4 mm thickness with required couplers, reducers, T-joints, Y-joints elbows and necessarysupports etc with sealing complete with provided control/ air flow regulating valves / dampers, filters at position. |
| 63 | ITEM No. 57 :- Supplying and erecting circular flexible / rigid PVC pipe duct of size 80 mm dia, 4 mm thickness with required couplers, reducers, T-joints, Y-joints elbows and necessarysupports etc with sealing complete with provided control/ air flow regulating valves / dampers, filters at position. |
| 64 | ITEM No. 58 :- SITC OF : DUCTING WITHINSULATION: 1. MOC : The ducts are made from GI sheet with TDF Flange (RectangularOR Square duct) duly factory made inclusive of all accessories ( Pl. specify GI coating ing/m2)2.GI gauge - 18/20/22 gauge3. Duct Insulation - 25mm thick class O-Highly flexible, closed-cell insulation material withlow thermal conductivity-Material type - Closed cell Elastomeric Rubber-Fire Retardant:Insulation material complies to Class \"O\" certification-Water vapour diffusion resistance-Should not support microbial growth (ASTM C1071, G21, G22)-Exposed Ducts - theexposed ducting which is open to be covered with 50mm thermocol with cement plaster.a. 18 guage with 25mm thick Class \"O\" insulationb. 20 guage with 25mm thick Class \"O\" insulationc. 22 guage with 25mm thick Class \"O\" insulation |
| 65 | ITEM No. 59 :- SITC OF :DUCTING WITH INSULATIONS: RETURN Air riser MOC :SS 304 Qty -4nos. each OT (1Lot):1. To be placed at the level approx 8 inches above from the floor level,2. Volume Control Dampers: manually operated dampers shall be provided for air flow control,3.MOC: made out of stainless steel or aluminum 0.8mm thick with matt polish with aluminum polished / powder coated grill from where the return air will be picked up.4.Riser grill : Grill opening size - 450 x 600mm5.MOC for grill: Aluminum Powder coated6.Ultraviolet (UV) tube - Each Riser to have a 6w UV Tube with quartz glass Prefilter, Flange Type06 NOS Grade : F7 (MERV13)Avg Efficiency : 80%=Em=90 % of0.4µm particles as per EN779 Media : Synthetic MediaConstruction : Flange Type, Media pleated with both side HDPE mesh with rod support MOC-Casing : AluminiumGasket : XLPE gasket on Downstream side of FlangeTemperature : Ambient |
| 66 | ITEM No. 60 :- Supply, fabrication, installation an testing of flexible canvass connections constructed between ductable unit / dampers / ducting of required size with fire resist flexible double canvas sleeve complete. |
| 67 | ITEM No. 61 :- Supply, installation, testing and commissioning of volume control box with collor for control damper of required sizes in GI construction complete with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete. |
| 68 | ITEM No. 62 :-SITC OF :Fire damper: 1. SUPPLY OF GSS FABRICATED MOTORISED COMBINATION FIRE & SMOKE DAMPER WITH FRAME & BLADES IN 1.6 MM THK GSS AND 432 MM SLEEVE OF MIN 20 G WITHOUT FLANGES, TESTED AND APPROVED BY CBRI ROORKEE AS PER UL 555, FIRE RATING 2HRS. 2. Spring return actuator with 10mm torque with control panel |
| 69 | ITEM No. 63 :- Supply ,installationtesting and commissioning of Actuators with Control Panel & Wiring |
| 70 | ITEM No. 64 :- Supply, installation, testing & balancing of Fresh Aircowel piece with degree, dampers, bird screen etc. for fresh air as per specification and approved shop drawing. |
| 71 | ITEM No. 65 :- Supply, installation, testing and comissiong of Return air risers grills made out from 22 s.w.g. SS 304, perforated grilles not less than 70% free area for air passage, hidden nut & bolt, flanges, all corner well covered, etc.front face of grille shall be flushed with wall, complete arrangement shall be leakproof with volume control dampers, filters etc. complete as required. Size ; 300mm x 500mm |
| 72 | ITEM No. 66 :- Providing adhesive thermal insulation for supply / return air duct with 19 mm nitrile rubber insulation having Rvalue as per the prevailing provisions in ECBC-2007. |
| 73 | ITEM No. 67 :- Supplying and fixing of 13 mm thickness closed cell nitrile rubber(class O\" ) insualtion with factory aluminium foil finished protective covering on Supply air duct inside the building afterapplying two coates of cold setting adhesive (CPRX compound).The joints shall sealed with50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. |
| 74 | ITEM No. 68 :- Supply, installation, testing and commissioning of 10mm thickarmasound open cell nitrile rubber Accoustic insulation from inside the ducts fixing with chemical adheave andfixing with washers, and nut bolt. |
| 75 | ITEM No. 69 :- Supply, installation & testing of28G Al Clading over Supply and Exhaust Air Ducts complete with required accessories screws supports etc. |
| 76 | ITEM No. 70 :- Supply, installation, testing and commissioning of underdeck insulation as per specifications. Material shall be 50mm thick TF quality expanded polystyrene slabs having density of 24 Kg/cu m and fixed by criss-cross wires and stays. |
| 77 | E) ELECTRICAL SYSTEM |
| 78 | ITEM No. 71 :- Supplying, erecting, testing and commissioning of diesel generating set with alternator of 82.5 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 14.0 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 145 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG 11-1-11(Ref-2022/23 CSR) Pg No 186/185 |
| 79 | ITEM No. 72 :- Supply, Installation, testing and commissioning of Microprocessor based AMF Panel suitable for diesel generating set of 62.5 Kva capacity Single/Three phase 230/415 Volts, 50Hz A.C. with all standard features , safties etc. as per specification no. GEN-AMF 11-2-9(Ref-2022/23 CSR) Pg No 191 |
| 80 | ITEM No. 73 :- SITC OF : AHU Control interface(ECI)With VFD: 1. VFD (Variable frequency drive for motor protection)2.MCB for AHU3.MCB for AC4.Contractor for controlling dehumidifier5.Scanner for HP/LP trip protection ( Full function control panel) |
| 81 | ITEM No. 74 :- SITC OF : OT Status Indicator with Fumes Recycler: This panel will incorporate automatic timer operated Fume recycler & Pre-set system mode to be operated from outside the OT. It should indicate the OT room pressure &temperature continuously ( HVAC SET BACK PANELS WHILE IN REST CONDITION i.e. NO OPERATIONAL HOURS) |
| 82 | ITEM No. 75 :- The OT passage area should be should be pressurized & fitted with an automated smoke exhaustmechanism to ensure efficient & effective protection. |
| 83 | ITEM No. 76 :- SITC OF: [Liebert 40KVA HipulseU ] Hipulse LIebert make Hipulse-U On-Line with inbuilt isolation transformer, 3 X 3, 40 kVA, 3 Phase, 6 Pulse, 415 V. Features:• Fully Digital, twin DSP controlled • Rated at 0.9 output power factor to deliver more active power • Handle leading power factor loads without KW derating under specified conditions • On-Line Double Conversion IGBT-based PWM Inverter • Wide input voltage tolerance (+20/-20%) • Wide input frequency range of 45Hz to 65Hz • High overload capability of static bypass (14 times for 10 milliseconds and 10 times for 100 milliseconds) • Capability to handle: High crest factor loads 100% non- linear loads 100% unbalanced loads • Built-in maintenance bypass • Front access for spares replacement and preventive maintenance • Easy Dual bus configuration architecture • Adjustable frequency synchronization window up to 6% in the static bypass • Field protocols ModBus / Jbus (optional) • Network protocols SNMP (optional) • Overload capability of the UPS: 110% full load for 60 minutes; 125% full load for 10 minutes; 150% full load for 1 minutes • Compact footprint Built Investment Protection • Automatic battery testing • Field settability of EOD of the battery • Selectable times for boost charging duration of the battery (15 steps with each step of 1 hour) • Protection against deep discharge of battery • Short circuit proof inverter •Back-feed protection • D- level lightning protection • With 3 auxiliary power supply to ensure redundancy under any condition • Standard dry contacts • Choice between 6 or 12 pulse rectifier for 120kVA to 500kVA capacity range • Choice of array of input harmonic filter options • Temperature- compensated battery charging (optional) HSN/SAC Code: 85044090 |
| 84 | ITEM No. 77 :- Supplyinginstallationtesting & commissioning of totally enciosed cubical indoor types PCC MV Panel floor /wall mountedfabricationwith 2mm thick sheet steel power coated withseventank treatment prosess,including providing & fixing the bus -bar chamber ,cable alley switch gearsmountingthere in,cable termination, interconnection as required suitablefor 415 Volts3 phase 4 wire50 HZ AC Supply as per specfication including numbering, earthing connection ect. as required.A.Incoming : 1. 1 No .100 AMPSTP +NMCCB ,25 KA fault rating with Micro- processor based release for protection as incomer 2. 1 Set of Aluminium bus bar suitble for 100 AMPS3. 1 No 500 VoltDigital Voltmeter with selector switch 4. 1 Set 100 Amps Digital Ammeter withCTS & seector switch 5. 1 Set phase indicating lamp with MCB Protection6. 1 Set ON /OFFindicating lamps withMCB for protectionB.Outgoing : 1. 1 Nos63 AMPS TP MCB with tharmalmagnetic rele,25 KAFault rating 2. 4 Nos40 AMPS TP MCB with tharmalmagnetic rele,25 KAFault ratingC.Starter : 1. VFD provision with bypass S/DStarter suitable for 7.5 KW motor with Overload, Single phasing, Under voltage and overvoltage, phase reverse protection with necessary internal wiring.D. AC controller : 1. 1 Nos fully automatic programmable temperature controller. To controls temperature by switching ON/OFF the compressors depending upon the return air temperature. |
| 85 | ITEM No. 78 :- INDUSTRIAL GRADE 3Ph Servo Controlled Voltage Stabilizer. I/p (300-460)VAC O/p (415)VAC.+/-1% |
| 86 | ITEM No. 79 :- Supplying, erecting& terminatingPVC armoured cable 4 core25sq mm copperconductor continuous 5.48 sq mm (12 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/CU 7-2-35(Ref-2022/23 CSR) Pg No 132 |
| 87 | ITEM No. 80 :- Supplying, erecting& terminatingPVC armoured cable 4 core10sq mm copperconductor continuous 5.48 sq mm (12 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/CU 7-2-33(Ref-2022/23 CSR) Pg No 132 |
| 88 | ITEM No. 81 :- Supplying, erecting& terminatingPVC armoured cable 4 core4sq mm copperconductor continuous 5.48 sq mm (12 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/CU (7-2-9) 7-2-31(Ref-2022/23 CSR) Pg No 132 |
| 89 | ITEM No. 82 :- Supplying, erecting& terminatingPVC armoured cable 3 core2.5sq mm copperconductor continuous 5.48 sq mm (12 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/CU7-2-14(Ref-2022/23 CSR) Pg No 131 |
| 90 | ITEM No. 83 :- Supplying, erecting& terminating2C x 0.75Sq.mm Shielded Sensor cable completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification |
| 91 | ITEM No. 84 :- Supplying and erectingG.I. Earth wire of high purity of diffrent sizes used for earthing or any other purpose on wallwith necessaryG.I. clamps fixed on wall/cable/conduit with screws in an approved manners ( 9-2-5)9-2-5(Ref-2022/23 CSR) Pg No 161 |
| 92 | ITEM No. 85 :- Providing & erecting Hot deeped Galvanised Perforated type Cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 75 mmheight complete with necessary coupler plates & hardware in approved manner (CB-CT) 7-11-6 (Ref-2022/23 CSR) Pg No 144 |
| 93 | ITEM No. 86 :- Supply & Erecting mains with 3x4 sq.mm and earth wire 2.5 sq.mm FRLS PVC Copper wire, in rigid PVC conduit min. 20mm dia. As per specification No. WG-MA/PC1-6-11(Ref-2022/23 CSR) Pg No 9 |
| 94 | ITEM No. 87 :- Supplying & erecting mains with 2x2.5 sq.mm. and earth wire 1.5 sq.mm FRLSH PVC copper wire in HMS PVC conduit min. 20mm dia. as per specification No: WG-MA/PC. 1-6-4(Ref-2022/23 CSR) Pg No 8 |
| 95 | ITEM No. 88 :- Supplying & installing UTP networking cat 7 cable , 4 pair 23 AWG cat6A LSZH LAN cable, standards like ANSI/TIA 568 C.2, EN50173, IEC 11801 2nd ED, 600Mhz Speed frequency tested upto 700Mhz with third party certificate etc complete. |
| 96 | ITEM No. 89 :- Providing & Fixing of Modular type Electrcial Switches and socketscomplete with metallic backing box ( 2 switches + 2 sockets ) to be provided in the wall cladding panels with covering plate. 5/16 A |
| 97 | ITEM No. 90 :- SITC OF: [12V100AH ] A MARARAJA QUANTA make 12V 100AH SMF Batteries. ( OneHour Backup)(1set= 34 nos battery ) * 2 Set= 68Battery HSN/SAC Code: 85072000 |
| 98 | ITEM No. 91 :- SITC OF: BATTERY RACK INTERLINKS ] Battery Rack and Interlinks,Rack suitable for above Batteries |
| 99 | F) VALIDATION & PERFORMANCE TESTING - TO BE INDEPENDENTLY CARRIED OUT PER OT ROOM |
| 100 | ITEM No. 92 :-Validation, Performance testing, balancing of the HVAC system designed to achieve the ISO 14644/1 classification Parameters• OT specifications - ISO Class 5 at LAF Plenum Exit & ISO Class 8 in the OT roomClean room validation to be done OT at rest & in operation conditions.a. Air balancing with Flow Hoodb. Room Pressure Balancingc. HEPA Filter Integrity Testd. Particle count test |
| 101 | G) ANNUAL MAINTENANCE CONTRACT |
| 102 | ITEM No. 93 :- COMPREHENSIVE TYPE ANNUAL MAINTENANCE CONTRACT FOR PERIOD OF FOUR YEAR THE CONTRACT SHALL START AFTER THE COMPLETION OF DEFECT LIABILITY PERIOD OF ONE YEARS. The contract shall be of comprehensive type complete with all required tools tackles, equipments, spares, all consumables including with refrigerent gas and oil to operate & maintain the ac plant in most efficient & trouble free manner. The contarct shall cover all reqd. Quarterly & yealry preventive maintenanace schedlues. The contract shall also cover attending all break down calls within 12 hours & Rectifying the problem within 24 hours. |
| 103 | ITEM No. 93.1 :- YEAR I |
| 104 | ITEM No. 93.2 :- YEAR II |
| 105 | ITEM No. 93.3 :- YEAR III |