| 1 | Dismantlingbrickmasonryinlimeorcement mortar and stacking the materils as directed with all leads, lifts etc. BDW 8 46.09 - As directed by Engineer in charge.(SSR No.: 46.09)- |
| 2 | Dismantlingstonemasonryinlimeorcement mortar including stacking the materils as directed withallleads,liftsetc.BDW846.11-As directed by Engineer in charge.(SSR No.: 46.11)- |
| 3 | Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etc,complete.BDW846.12-Asdirectedby Engineer in charge.(SSR No.: 46.12)- |
| 4 | Removingcementtiles,ormarbleorpolished shahabadfloorordadowithoutbedconcrete including stacking the materials as directed with allleads, liftsetc.complete BDW846.19- As directed by Engineer in charge.(SSR No.: 46.19)- |
| 5 | Removing cement or lime plaster including disposing of the spoils as directed with all leads, lifts etc, complete. BDW 8 46.2100000000001 - As directed by Engineer in charge.(SSR No.: 46.21)- |
| 6 | ProvidingandlayingCastinsitu/ReadyMix cement concrete in M-10 of trap/ granite/ quartzit/ gneiss metal for foundation and beddingincludingbailingoutwater,formwork, laying/pumping, compacting, roughening them if specialfinish istobeprovided,finishing if requiredandcuringcomplete,withfully automatic micro processor based PLC with SCADA enabledreversibleDrumTypemixer/concrete Batch mix plant (Pan mixer) etc. complete.With natural sand/V.S.I. quality Artificial Sand BDE 124.01 - Bd. E. 1 Page No. 287(SSR No.: 24.01)- |
| 7 | Providingand layingin situ/Ready Mix cement concreteM-20oftrap/granite/quartzite/ gneissmetal for R.C.C. workin foundations like raft,stripfoundations,grillage and footingsofR.C.C. columns and steel stanchionsetc. including bailing out water, formwork, laying/pumpingcoverblocks,compactionand curing roughening the surface if special finish is tobeprovided(Excludingreinforcementand structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabledreversibleDrumTypemixer/concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand BDF 325.11 - Bd.F.3 page no.298 and B.7,Page no.38 |
| 8 | ProvidingandlayingCastinsitu/ReadyMix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. PARDIof reqd thk. asperdetaileddesignsanddrawings including centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfacesof sufficient minimum thickness to give asmoothandevensurfaceorrougheningif specialfinishistobeprovidedandcuringetc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLCwithSCADAenabledreversibleDrumType mixer/ concrete Batch mix plant (Pan mixer) etc. complete. Withnaturalsand/V.S.I. quality Artificial Sand BDF 11 P.NO.304,B7 P.NO.38(SSR No.: 26.17)- |
| 9 | Providingand fixingin positionTMT - FE - 500 bar reinforcement of various diameters for R.C.C. pilecaps,footings,foundations,slabs,beams columns,canopies,staircase,newels,chajjas, lintelspardis,copings,fins,archesetc.asper detaileddesigns,drawingsandschedules. includingcutting,bending,hookingthebars, bindingwithwiresortackweldingand supporting as required complete. BDF 17 26.33 -Bd. F. 17 Page No. 306 /I.S. 456 (2004(SSR No.: 26.33)- |
| 10 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6inplinthasbackingincompositemasonry includingbailingoutwatermanually,striking joints, raking out joints and watering etc Complete. BDG 2 27.03 - Bd.G.2 Page No. 313(SSR No.: 27.03)- |
| 11 | Providing internal cement plaster 20mm thick in twocoatsincementmortar1:4withoutneeru finish, to concrete, brick surface, in all positions includingscaffoldingandcuringetc.complete.BDL 4 32.07 - Bd.L.4 Page No. 368(SSR No.: 32.07)- |
| 12 | Providing and applying water proofing treatment usingacrylicpolymermodifiedcementbased waterproofingcoatingwithfibreglassmesh mixing at the rate ofpowder to liquid (2:1) by weight covering 9 to 10 sqm /kg with two coat using Dr. Fixit or alike of chemicals for masonry and concrete surface by brush covering 7 years guarantee onStamp Papers etc. complete. BDJ31.09 - As directed by Engineer in charge.(SSR No.: 31.09)- |
| 13 | Providing and laying ceramic tiles of having size30cmx30cmconfirmingtoI.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortarincludingcementfloat,fillingjointwith white/colourcementslurrycleaningcuringetc. complete. BDM 15 33.24 - Bd.M.29 Page No. 391(SSR No.: 33.24)- |
| 14 | Providing and laying ceramic tiles ofhaving size 30 cm. x 30 cm. and confirming to correspondingI.S.fordadoandskirtinginrequiredposition withreadymadeadhesivemortarofapproved quality on plaster of 1:2 cement mortar including jointfillingwithwhite/colourcementslurry cleaningcuringetc.complete.BDM1233.25- Bd.M.12 Page No. 385.(SSR No.: 33.25)- |
| 15 | Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red/OceanBrowngranitestoneof approved shade and size 18 mm to 20 mm thick onbed1:6cementmortarincludingcement floats striking joints, pointing in C.M. 1:3 curing andcleaningetc.complete.BDM3533.34-Bd.M.35 B/P No.393(SSR No.: 33.34)- |
| 16 | Providingandfixingheavydutyinterlocking concrete Coloured paving blocks of 60 mm thickness of having a strength of 300 kg/Sq.cm. ofapprovedqualityandshapeonabedof crushedsandof25to30mmthickincluding skirtingjointsandcleaningetc.completeBDM33.51 - A directed by Engineer in charge(SSR No.: 33.51)- |
| 17 | ProvidingandlayingCastinsitu/ReadyMix cementconcreteM-15oftrap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing unevenandhoneycombedsurfaceandcuring etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laidconcrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) BDE 3 24.16 - Bd.E. 3/Page No. 288/I.S. 456 (2000)(SSR No.: 24.16)- |
| 18 | Providing and erecting chain link fencing 1.6 M. height with G.I. chain link of size 50x 50 mm, 8 gauge thick and fixed 75 mm above ground level on vertical M.S. Angles of 40 x 40 x 6 mm size, includind excavating pits for foundation and embedded in C.C. block of 1:4:8 mix of size 450 x 450x670mm. at 1.75M. c/c withironbar 16mm dia as hold fast including welding link with angle frame at 30 cm c/c with nuts and bolts and horizontal M.S. Angles at top and bottom of 25 x 25 x 5 mm size and vertical M.S. flat 35 x 5 mm and 25 x 5 mm horizontal including cross support of40x40x6mmanglesbothsideatevery corner or bend embedded in concrete blocks of 1:4:8 of size 450 x 450 x 670 mm including 3 coats of oil painting etc. complete. BDW 46.39 - As directed by Engineer in charge.(SSR No.: 46.39)- |
| 19 | Providingandlayingintrenches40mmdia. heavy grade having embossed as ISI Mark galvanised iron pipes of 4.49 kg/metre necessary fittingremakinggoodthedemolishedportion with fillingtrenchesandwith primerof anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary andconveyingandstackingthesameinPWD chowkyorasdirectedetc.complete.BDV543.13 - Bd.V.5 Page No. 551(SSR No.: 43.13)- |
| 20 | Providingandlayingintrenches25mmdia. heavy grade having embossed as ISI Mark galvanised iron pipes of 3.01 kg/metre necessary fittingremakinggoodthedemolishedportion with fillingtrenchesandwith primerof anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary andconveyingandstackingthesameinPWD chowkyorasdirectedetc.complete.BDV543.11 - Bd.V.5 Page No. 551(SSR No.: 43.11)- |
| 21 | Providing and fixing 40 mm. dia Ball cock mediumtypewithPVCfloatincludingsockets and necessary fittings and tested as per municipal requirements etc. complete. BDV 42.36- As directed by Engineer in charge.(SSR No.: 42.36)- |
| 22 | Providing, laying and fixing P.V.C. pipe of 25mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trenchfillingetc.complete.Includingremoving existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete.BDV6042.23-Asdirectedby Engineer in charge.(SSR No.: 42.23)- |
| 23 | Providing, laying and fixing P.V.C. pipe of 40mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trenchfillingetc.complete.Includingremoving existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc.complete.BDV6042.25-Asdirectedby Engineer in charge.(SSR No.: 42.25)- |
| 24 | Conveying materials obtained from road cutting includingalllifts,layinginlayersof20cmto 30cm.breakingclods,dressingtotherequired lines, curves, grades andsection, wateringand compactingtonotlessthan97%ofstandard Proctor density for a lead of over 50m. to 300m. inclusive from the site of excavation to the site of deposition as directed. MORTH 305 2.24 -MORTH 501(SSR No.: 2.24)- |
| 25 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminiumconductor complete erected with glands & lugs, on wall/ trusses/pole or laid inprovidedtrench/pipeasperspecificationno. CB-LT/AL (PWD ELECTRICAL CSR-2022-23) |
| 26 | Makingtrench in soft soil having0.75 m depth and minimum 0.3 m widthfor laying provided cables up to voltage level of 1.1kV complete As perspecification No. CW-EXN-CTR (PWD ELECTRICAL CSR-2022-23)(SSR No.: 16-1-1) |
| 27 | Supplying,erecting&markingTPMCB40Ato 63A, with rated short - circuitbreaking capacity (Icn) 10kA in provided distribution board as per specificationno. SW-SWR/MCB (PWD ELECTRICAL CSR-2022-23)(SSR No.: 5-3-11) |
| 28 | Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breakingcapacity25kA(Ics=100%ofIcu),adjustable thermal (overload) setting and fixedmagneticsettingwithprovidedleads,provision for installation of shunt/UV/tripalarm contact. MCCB with phase barriers on both sides, insulation withstandcapacity800V,noline-loadbiasinprovided enclosure/panel as per specificationno.SW-SWR/MCCB(PWDELECTRICAL CSR-2022-23)(SSR No.: 5-5-1) |
| 29 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB(PWD ELECTRICAL CSR-2022-23)(SSR No.: 5-3-2) |
| 30 | Supplyinganderectingsinglepoleandneutral distribution board (SPNDB),with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs, withdoor, 1.2mm thickness surface / flush mounted,IP 43 Protection on iron / GIframeas perspecificationno.SW-SWR/MCBDB (PWD ELECTRICAL CSR-2022-23)(SSR No.: 5-4-7) |
| 31 | Supplying&erectingflatflexible3core2.5 sq.mm PVC sheathed submersibletypecoppercablesuitablyclampedatfixed intervals with column pipe assemblycomplete.(PWD ELECTRICAL CSR-2022-23)(SSR No.: 12-4-8) |
| 32 | Supplying and erecting minimum Three & above star rated submersiblepumpsetsuitableforerectiononopenwellof 5.625 KW/7.5 HP with 415 V50c/s.A.C.supply,havingdeliveryheadfrom 57 to 22 m and discharge from120 to 900 litres. . per minute & pipe of Suction 75 mm/Delivery 65 mmdiameter erected with necessary H type clamps as per specification No. WP-OSP (PWD ELECTRICAL CSR-2022-23) |
| 33 | Supplying and erecting minimum Three & above star rated submersiblepumpsetsuitableforerectiononopenwellof3.75 KW/5 HP with 415 V 50c/s. A.C. supply, having delivery head from 43 to 11m and discharge from 120to 840 litres. per minute & pipe of Suction 65mm/ Delivery 50 mmdiameter erected with necessary H type clamps as per specification No. WP-OSP (PWD ELECTRICAL CSR-2022-23)(SSR No.: 12-3-2) |
| 34 | Supplying&erectingD.O.LStartersuitablefor 415 V, 3 phase 50 cycles with novoltcoilandoverloadelementwithnecessary materials and connected to supplyup to 7.5 H.P. (PWD ELECTRICAL CSR-2022-23)(SSR No.: 12-4-2) |
| 35 | Supplying and erecting integrated LED flood light fitting Max. 50W IP65 &IK07classhavingpressuredie-castaluminium housing, having system lumensoutput of Min. 5000 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCTupto6500K,THD<10%,p.f.>0.90,operating range of 140-270V, inbuilt surgeprotectionof4 kV, Lifeclass of50,000 Hrs. at L70B50, including driver with Ushapedbracketwith3Yearswarrantyasper specification No FG-ODF/FLS2. (PWD ELECTRICAL CSR-2022-23)(SSR No.: 2-4-13) |
| 36 | Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVCinsulatedwirelaidinprovided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW (PWD ELECTRICAL CSR-2022-23)(SSR No.: 1-3-1) |
| 37 | Supplying and erecting metal work in CRCA sheet including Iron work forsupports with fabrication of boxes, panel boards, etc. including cutting,bending, drilling, welding, riveting, treated with anti-rust treatment and dulypowdercoatedorpaintedwithonecoatofred lead paint and 2 coats of enamelpaint complete (PWD ELECTRICAL CSR-2022-23)(SSR No.: 6-1-1) |
| 38 | Providngearthingwithgalvanizedironearth plate size 60 x 60 x 0.6 cmcomplete with all materials, testing & recording the results as per specification no.EA-EP (PWD ELECTRICAL CSR-2022-23)(SSR No.: 9-1-1) |
| 39 | Supplying and erecting four pole power contactor 430 V, 40 A for time switchcompleteerectedonprovidedwoodenblock/ box, with necessary materials. (PWD ELECTRICAL CSR-2022-23) |
| 40 | Supply,installation,testingandcommissioning wireless remote control havingcolourLCDpanel,realtimeclock,temperature limitation (16 to 30° C,functions like filter clean reminder timer suitable to communicate with wiredcontrollercomplete.(PWDELECTRICAL CSR-2022-23)(SSR No.: 3-11-78) |
| 41 | Contractor has to quote on Work Portion Only |