Tender For Repairing Of Plaster, Door, Window, Removing Of Seepage And External /Internal Painting Work Of Hostel No. 1 And 2 At Residential Coaching Academy, Jamia Millia Islamia.
Tender Value
18.08 Lakhs
Estimated cost
Bid Submission
01 Jul 2024
0 days left
EMD
36200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Repairing Of Plaster, Door, Window, Removing Of Seepage And External /Internal Painting Work Of Hostel No. 1 And 2 At Residential Coaching Academy, Jamia Millia Islamia.
BOQ
| Sl. No. | Item Description |
| 1 | Civil Work |
| 2 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level._Cement mortar 1:3 (1 cement :3 coarse sand) |
| 3 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws._Kiln seasoned and chemically treated hollock wood_30 mm thick |
| 4 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters._35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 5 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 6 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : (copper oxidized as per IS: 1378)_200x10 mm |
| 7 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : (copper oxidized as per IS: 1378)_150x10 mm |
| 8 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :_300x16 mm |
| 9 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :_250x16 mm |
| 10 | Welding by gas or electric plant including transportation of plant at site etc. complete. |
| 11 | 12 mm cement plaster of mix :_1:6 (1 cement: 6 fine sand) |
| 12 | 12 mm cement plaster of mix :_1:4 (1 cement: 4 coarse sand) |
| 13 | Distemperingwith 1stqualityacrylicdistemper (ready mixed)havingVOCcontentlessthan50gram/litre,of approved manufacturer, of required shade and colour all complete:_New work (two or more coats) over and including water thinnableprimingcoat withcement primerhavingVOC content less than50 pram/litre |
| 14 | Finishingwallswithwaterproofingcementpaintofrequired shade_New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 15 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 16 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required said and colour complete to give and even said._Old work (one or more coats) |
| 17 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 18 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :_One or more coats on old work |
| 19 | Finishing walls with water proofing cement paint of required shade : |
| 20 | Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 litrs/10 sqm complete including cost of Priming coat. |
| 21 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge._With cement mortar 1:4 (1 cement : 4 fine sand) |
| 22 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge._With cement mortar 1:4 (1cement: 4 coarse sand) |
| 23 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:_Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 24 | Renewing glass panes and refixing existing wooden fillets:_Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 25 | Renewal of old putty of glass panes (length) |
| 26 | Refixing old glass panes with putty and nails |
| 27 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 28 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes._110 mm diameter |
| 29 | Providing and fixing onwall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion._Single tee with door_110x110x110 mm |
| 30 | Single tee without door_110x110x110 mm |
| 31 | Bend 87.5°_110 mm bend |
| 32 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete._10 litre capacity - White |
| 33 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete._Flexible pipe_32 mm dia |
| 34 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :_Rectangular shape 453x357 mm |
| 35 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall_20 mm dia nominal bore |
| 36 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall_25 mm dia nominal bore |
| 37 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall_50 mm dia nominal bore |
| 38 | Providing and fixing uplasticised PVC connection pipe with brass unions :_45 cm length_15 mm nominal bore |
| 39 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :_20 mm nominal bore |
| 40 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :_25 mm nominal bore |
| 41 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :_50 mm nominal bore |
| 42 | Providing and fixing double scaffolding system of bamboo and chali all the jiont must be tied with coconut rope upto the height of 30 meter complete asdirected by Engineer- in-charge .The elevational area of the scaffolding shall be measured for payment purpose |
| 43 | Add for revised GST @18% in place of 12% ie 6.33% on 1701172 |
AI Tender Summary
Tender Timeline
Jun 25, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedJul 01, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJul 03, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender