| 1 | BOQ for Works contract for replacement of old AC sheets with PPGI sheets in Power House Area at BHEL-SBD,Banaglore |
| 2 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material to the identified location inside factory premises of Asbestos Cement Sheets. Including chipping off the sheets embedded in the side wall and making grooves for fixing new sheet. |
| 3 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrogation as approved by Engineer In-charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120grams per sqm as per IS: 277, in 240MPa Steel grade, 5-7 micron epoxy primer on both sides of the sheet and the polyester top coat 15-18 microns. Sheets shoud have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 metre or as desired by Engineer In-charge. The sheet shall be fixed using self drilling/ self tapping screws of size (5.5x55mm) with EPDM seal, complete up to any pitch horizontal, vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Also including inserting the sheets into the side wall grooves and packing it using Cement Mortar 1:4 including the cost of all materials and labour. |
| 4 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 Mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete: North Light Curves |
| 5 | Providing and Fixing 1.2mm Pre-Painted / Powder Coated Galvanized iron gutters of required shape, with gutters joint end to end using lap joints not less than 100mm. Weatherproof silicon sealant to be provided in-between the lap joints covering not less than 70% of the lap area and both lap ends will be either rivetted with spacing not less than 100mm or properly welded. If welded, the welding portion to be painted by epoxy paint to prevent corrosion of the welded portion. Gutters to be supported using the MS Flats (painted with red-oxide and 2 coats of enamel paint) and fixed to the support using self tapping screws. Girth Varying form 600-1200mm. Also including the cost of making opening for fixing rainwater pipes including providing suitable funnel for connecting rain water pipes. |
| 6 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes confirming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion (i) Single Socketed pipes. 110mm diameter including fittings and fixtures all complete. |
| 7 | Providing and fixing on wall face unplasticised PVC Moulded Fittings/ Accessories for unplasticised Rigid PVC rain water pipes confirming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion:110mm Bend 87.50, |
| 8 | Demolishing brick work manually/ by mechanical means including stacking of servicable materials and disposal of unservicable materials to the identified location inside factory premises as per direction of Engineer In-charge. In Cement Mortar. Working height up to 8m. |
| 9 | Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement Mortar1:4 (1 cement : 4 coarse sand) |
| 10 | Cement plaster (in fine sand): 20mm cement plaster of mix: 1:4 (1 cement : 4 fine sand) |
| 11 | Providing and fixing wirecast glass panes with putty and glazing clips in North Light roof cladding, steel doors, windows, clerestory windows, all complete with: 6mm thick wire cast glass. |