Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-07-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 19-07-2024 |
| 2 | 05-07-2024 | Fee | Other | 12-07-2024 |
| Sl. No. | Item Description |
| 1 | M&L for servicing of Indoor unit & Out door unit of Split type AC of 1.5 tone capacity by taking out the same from existing location , cleaning , dusting, brushing, checking and rectify electrical conections, condenser , cooling coil and other components withcooling coil rinse solution without damage any part and reinstall at the same location and clean water with water pressure gun, greasing of fan , motor , blowerincluding acid/detergent foam type wash etc complete all as specified and directed by Engineer-in-Charge. |
| 2 | All as per item No 01 above but split type AC of 2.0 ton |
| 3 | M&L for servicing of Window type AC of 1.5 tone capacity by taking out the same from existing location , cleaning of condenser , cooling coil and other componentswith cooling coil rinse solution and clean water with water pressure gun, greasing of fan , motor ,brushing cleaning with blower including acid/detergent foam type washetc without damage any part and reinstall at the same location complete all as specified and directed by Engineer-in-Charge. |
| 4 | M&L for finding out the leakage the pressure test of the condenser of cooling coil of window type AC/split type AC of 1.5 ton and dismantling the same for repair the leakage point by brazing/ soldering including charging the gas R-22 ,R-32, R-410 and testing the AC to complete all as specified and directed by Engineer-in-Charge. |
| 5 | All as per item No 04 above but split type AC of 2.0 ton |
| 6 | M&L in repair for taking out unserviceable sealed unit (compressor) 1.5 ton capacity , single phase, 230 volt of models as existing and replacing the same with new sealed unit (compressor)including necessary modification of the foundation as required to suit the compressor, vacumacation, pressure , testing, leaking, rectification incl gas charging R-22,R-32 ,R-410 and testing complete to complete all as specified and directed by Engineer-in-Charge. |
| 7 | All as per item No 06 above but 2 TR |
| 8 | M&L for Split type AC outdoor unit (suitable for existing AC) complete only of capacity 1.5 TR complete all as specified and directed by Engr-in-charge Make : Voltas, Blue star, LG , Hitachi,Lloyd( Havells) or its equivalent |
| 9 | M&L for Removing the split type AC 1.5 ton/ 2 ton capacity working on230 V single phase /440 Volt 3 phasecomplete including indoor and out door unitall as directed including making good of all disturbed surfaces. |
| 10 | M&L forreinstall at anyplace ( with in thestn )at height up to 5 mtr from floor level including replacement of refrigerant tubing upto 7.5 mtrs length and provision of drain pipe and pipe insulation, connecting with existing power socket and testing the unit for smooth functioning including making good of all disturbed surfaces complete all as specified and directed by Engineer-in-Charge. |
| 11 | M&L for Split AC Indoor unit (suitable for existing AC ) complete of capacity 1.5 TR complete all as specified and directed by Engineer-in-Charge. |
| 12 | M&L for stand ( wall mounted type & Floor mounted type ) of suitable for split type AC complete all as specified and directed by Engineer-in-Charge. |
| 13 | M& L forPVC drain pipe complete all as specified and directed by Engineer-in-Charge. |
| 14 | M&L for providing nitril rubberthermal insulation to copper tubing’s from Indoor to outdoor units with foam pipe insulation ( 1/2\" ID X 1/2\" thk) followedwith clamps complete all as specified and directed by Engineer-in-Charge. |
| 15 | M&L for repair to PCB cardofwindow / Split type AC for remote operation complete testing and installation and all electrical connections including replacement of defectiveelectronic components / IC Circuits complete all as specified and directed by Engineer-in-Charge. |
| 16 | M&L for repair to PCB Card ofinverter type split AC for remote operation complete testing and installation and all electrical connections including replacement of defectiveelectronic components / IC Circuitscomplete all as specified and directed by Engineer-in-Charge. |
| 17 | S&F in replacmemt remote control unit (cordless) as per existing model forAC unit complete all as specified and directed by Engineer-in-Charge. |
| 18 | S & F Air filter suitable for 1.5 ton split typeACas required on site incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge. |
| 19 | All as per item No 18 above but split type AC of 2.0 ton |
| 20 | S & F Thermostat suitable of 1.5 ton split ACas required on sitecomplete all as specified and directed by Engineer-in-Charge. |
| 21 | All as per item No 20 above but split type AC of 2.0 ton |
| 22 | S & F Single pole contactor for Split type AC 50/60 Hz 240 Vcomplete all as specified and directed by Engineer-in-Charge. |
| 23 | S & FAxilary contactorsingle phase 220 Volts 10 Amps current capacity complete all as specified and directed by Engineer-in-Charge. |
| 24 | S & F Start Relay suitable of 1.5/2 ton split ACas required on sitecomplete all as specified and directed by Engineer-in-Charge. |
| 25 | M&L forreplace copper condenser coil assembly complete suitable for 1.5 ton split type AC suitable for existingincl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge. |
| 26 | M&L forreplace copper condenser coil assembly complete suitable for 2 ton split type AC suitable for existing incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge. |
| 27 | M&L forreplace copper condenser coil assembly complete suitable forwindow type AC suitable for existing incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge. |
| 28 | M&L for replaceevaporator coil assembly complete suitable for1.5ton Split type ACsuitable for existing incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge. |
| 29 | M&L for replaceevaporator coil assembly complete suitable for2 tonSplit type AC suitable for existing incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge. |
| 30 | M&L for replaceevaporator coil assembly complete suitable for Window type AC suitable for existingincl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge. |
| 31 | S&F in replacement of copper tubing 5/8” outer dia suitable for 1.5/2 TR AC including nitril rubberthermalinsulation capacity complete all as specified and directed by Engineer-in-Charge. |
| 32 | S&F in replacement of copper tubing 3/8” outer dia suitable for 1.5/2 TR AC including nitril rubberthermalinsulation capacity complete all as specified and directed by Engineer-in-Charge. |
| 33 | S&F in replacement of copper tubing 1/4” outer dia suitable for 1.5/2 TR AC including nitril rubberthermalinsulation capacity complete all as specified and directed by Engineer-in-Charge. |
| 34 | S&F in replacementof condensing fan motor of capacitysuitable for Split AC 1.5/2 Ton testing on load for complete all as specified and directed by Engineer-in-Charge. |
| 35 | S&F in repairs running capacitor of capacity ‘45+5’ MFD, 240 volts, 50 Hz complete all as specified and directed by Engineer-in-Charge. |
| 36 | All as per item No 35 above but capacity 36 MFD |
| 37 | S&F in replacementblower suitable for existing Split AC complete all as specified and directed by Engineer-in-Charge. |
| 38 | S&F in repairs blower fan motor of capacity 1/30 HP, 3 speed, single phase (as persample)complete all as specified and directed by Engineer-in-Charge. |
| 39 | S&F in repair condenser fan motor of capacity 1/20 HP, single phase (as per sample) complete all as specified and directed by Engineer-in-Charge. |
| 40 | S&F in repair starting capacitor of capacity 60 MFD, 40 volt, 50 Hz complete all as directed by Engineer-in-Charge. |
| 41 | S&F in repairs starting capacitor of capacity 100-120 MFD , 440 volts, 50 Hz complete all as specified and directed by Engineer-in-Charge. |
| 42 | S&F in replacement of DC fanmotor of split AC unit with supper enameled copper wire of suitable gauge wire and testing on load for the complete all as specified and directed by Engineer-in-Charge. |
| 43 | S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 25 Amp complete all as specified and directed by Engineer-in-Charge. |
| 44 | M&L for Sub main wiring with twosingle core, 4 Sqmm, PVC insulated PVC unsheathed stranded FRLSH copper conductor cable including PVC concealed/ surfaceconduit of earth wire with 1 x 4 Sq mmcopper cable fixed along with the sub main in PVC conduit and connecting to earth dolly complete all as specified and directed by Engineer-in-Charge.Note : Two run of 4 Sqmm wire shall be measured as single run. |
| 45 | S&F in repairs of cable 3 core 4 sqmm FRLS PVC copper conductor complete all as specified and directed by Engineer-in-Charge. |
| 46 | M&L for servicing of Refrigerator any size at existing location , cleaning , dusting, brushing, checking and rectify electrical conections, condenser , cooling coil and other components with cooling coil and other components with cooling coil rinse solution without damage any part at the same location complete all as specified and directed by Engineer-in-Charge.Note:- Componentsreqd to bereplaced will be measuredand paid separately |
| 47 | Supply only the following parts/components of refrigerator/Deep Freezer of 165/190/315/324/360/388/425 Ltr capacity complete all as specified and directed by Engineer-in-Charge.(a) Box type relay |
| 48 | All as per item No 47 above but Thermostat with control knob |
| 49 | All as per item No 47 above butDrier |
| 50 | All as per item No 47 above but Condenser |
| 51 | All as per item No 47 above but Copper capillary Tube |
| 52 | All as per item No 47 above butMagnetic door gasket |
| 53 | All as per item No 47 above but Chiller tray |
| 54 | All as per item No 47 above but Vegetable tray PVC |
| 55 | All as per item No 47 above but Aluminium grill rack PVC Coated) |
| 56 | All as per item No 47 above but Pigmy lamp 15W with screwed/Bayonet Cap |
| 57 | M & L for replacement of unserviceable sealed compressor with new hermetic sealed compressor of up to capacity 325 Ltr as existingmake including charging of refrigerant gas and testing on full load complete all as specified and directed by Engineer-in-Charge. |
| 58 | All as per item No 57 above but capacity of refrigerator 360 Ltr |
| 59 | M&L for servicing of Deep freezer of size 320/425 Ltr at existing location , cleaning , dusting, brushing, checking and rectify electrical conections, condenser , cooling coil and other components with cooling coil and other components with cooling coil rinse solution without damage any part at the same location complete all as specified and directed by Engineer-in-Charge. |
| 60 | M & L for replacement of unserviceable sealed compressor with new hermetic sealed compressor of capacity 425 Ltr as existingmake including charging of refrigerant gas and testing on full load complete all as specified and directed by Engineer-in-Charge. |
| 61 | M & L for servicing of Water cooler of any capacity at existing location by cleaning of condenser, cooling coil, and other components with cooling coil Rinse solution & clean water, greasing of fan, motor including cleaning of storage tank with treated water after applying the potassium permanganate solution etc without damage any parts incl replacement ofcomplete all as specified and directed by Engineer-in-Charge. |
| 62 | S&F in replacement of starting relay as requiredat site for water coolers complete including connecting, testing complete all as specified and directed by Engineer-in-Charge. |
| 63 | S&F in replacement of waste water tray as required at site made out of 20 gauge GI sheet complete with PVC drain pipe including painting with PVC drain pipe including painting with aluminum paint complete all as specified and directed by Engineer-in-Charge. |
| 64 | S&F in replacement of brass float valves accessories 15mm size as required at site complete all as specified and directed by Engineer-in-Charge. |
| 65 | M&L for Disconnecting and taking down water cooler of any make and size for repairs including detection of leakage in the system rectifying the same, dehydration & recharging of gas testing the water cooler for smooth & satisfactory working complete all as specified and directed by Engineer-in-Charge. |
| 66 | S&F in replacement of CP push cock ISI marked 15mm base complete all as specified and directed by Engineer-in-Charge. |
| 67 | S&F in replacement of condenser fan motor single phase as required at site for water cooler with clamps, bolts, nuts & rubber bushes complete including connecting testing complete all as specified and directed by Engineer-in-Charge. |
| 68 | M&L for Replacement of wiring kit for water cooler of any make and capacity. complete all as specified and directed by Engineer-in-Charge. |
| 69 | M & L for taking out unserviceable sealed unit (compressor) of water cooler 150/150 Ltrs capacity single phase 230 volt ofas existing model and replacing the same with new sealed unit (Compressor ) including necessary modification of the foundation as required to suit the compressor, vacumisation presser testing, leakage rectification incl gas charging and testing complete all as specified and directed by Engineer-in-Charge. |
| 70 | All as per item No 69 above but compressor as existing model and replacing the same with new sealed unit (Compressor)for water cooler 80/40 Ltr capacity complete all as specified and directed by Engineer-in-Charge. |
| 71 | M & L for servicing of desert cooler of any capacity at existing location by cleaning ofallcomponentswithRinse solution & clean water, greasing of fan, motor including cleaning of water storage tank with treated water after applying the potassium permanganate solution etc without damage any parts incl replacement of small parts like PVC water distributer, flexible pipe, plugs etc as required on site complete all as specified and directed by Engineer-in-Charge. |
| 72 | M & L for scraping and removing old paint of desert cooler body (steel surfaces) and preparation of steel surfaces including necessary denting, cutting, welding etc for spray painting with approved smoke gray synthetic enameled paint (Ist quality) over a coat of Zinc chromate primer on outer surface and inner surface i.e. Water tank and body fan mounting blades shall be painted with a coat of anticorrosive black paintover a coat of Zinc chromate primer complete for desert cooler of any size and capacity complete all as specified and directed by Engineer-in-Charge. |
| 73 | S & F in replacement Desert cooler Pump as per existing capacity complete all as specified and directed by Engineer-in-Charge. |
| 74 | M & L for replacement of cooling fan motor supporting legs andPVC fan blade of 450 mm sweep for desert cooler complete all as specified and directed by Engineer-in-Charge. |
| 75 | M & L for rewinding of desert cooler motor of any make with supper enameled copper wire (Thermal class E) of appropriate sizeincluding replacement of gun metal bushed and steel shaft complete all as specified and directed by Engineer-in-Charge. |
| 76 | M & Lin replacementof 01 Nos front grill and 3 side loovers suitable for disert cooler duly spray painted with approved paint over a coat of red oxide primer and internal surface of body cooler pump and motor shall be painted with two coat of bituminous paint over a coat of red oxide primer as required on site complete all as specified and directed by Engineer-in-Charge. |
| 77 | S&F in replacement of Desert cooler motor copper wound as existing complete all as specified and directed by Engineer-in-Charge. |
| 78 | M & L for replacement of desert cooler body 660x660x900mm with front grill and three side louver fabricated out of 22 gauge mild steel plan black sheet and bottom water tank (sump) of size 660x660x200mm deep fabricated out of 20 gauge milled steel plan black sheet including taking out and reinstallation complete with standard fitting such as PVC pipe for water electric controls and switch, fan speed regulator rewiring of fan motor and water lifting pump including fixing and connecting existing cooler fan and electric pump with 3 core PVC insulated & PVC sheathed cables (min3 mtr in length).External surface shall be spray painted with approved paint over a coat of red oxide primer and internal surface of body cooler pump and motor shall be painted with two coat of bituminous paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. |
| 79 | M & L for replacement of running cap 4.0 MFD 440 volt complete all as specified and directed by Engineer-in-Charge. |
| 80 | M & L for replacement of wood wool pad 25mm thick duly winded with the nylon mesh of standard size for 4000 cum/hr capacity desert coolers complete all as specified and directed by Engineer-in-Charge. |
| 81 | S&F in replacement plug top 5 Amps complete all as specified and directed by Engineer-in-Charge. |
| 82 | S&F in replacement selector switch as required at site and complete all as specified and directed by Engineer-in-Charge. |
| 83 | S&F in replacement of rotary switch as requirement at site complete all as specified and directed by Engineer-in-Charge. |
| 84 | S&F in replacement of PVC water distributer flexible pipe with TEE and all accessories in desert coolercomplete all as specified and directed as requirement at site complete all as specified and directed by Engineer-in-Charge. |
| 85 | S&F in replacement of piano type 05 amp switch 230 volt , AC complete all as specified and directed by Engineer-in-Charge. |
| 86 | S&F cable copper conductor PVC insulated FRLS 2 core 1.5 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 87 | M&L for servicing, repair of Voltage stabilizer of capacity 4 / 5 KVAcleaning , dusting, brushing, checking and rectify electrical conections, and other components complete all as specified and directed by Engineer-in-Charge. |
| 88 | S&F in repairs time delay relay suitable for 4/5 KVA voltage stabilizer complete all as specified and directed by Engineer-in-Charge. |
| 89 | S&F in repirs diode suitable for voltage stabilizer of capacity 4/ 5 KVA complete all as specified and directed by Engineer-in-Charge. |
| 90 | S&F in repairs condenser suitable for voltage stabilizer of capacity 4/5 KVA complete all as specified and directed by Engineer-in-Charge. |
| 91 | S&F electronic circuit board with relay suitable for 4/5 KVA voltage stabilizer of any make and testing complete all as specified and directed by Engineer-in-Charge. |
| 92 | M&Lin repair transformersuitablefor voltage stablizer 4/5 KVAas required on site complete all as specified and directed by Engineer-in-Charge. |
| 93 | S&F in repairs and replacement of voltage stabilizer of capacity 5 KVA input variation between 170 volts to 250 volts with output voltage stabilized at 230 with accuracy of +-2.5% and capacity 5 KVA complete all as specified and directed by Engineer-in-Charge. |
| 94 | M&L for Exhaust fan motor for 300 mm sweep ( as per suitable for exixting) complete all as specified and directed by Engineer-in-Charge. |
| 95 | S&Fwall mountingfan motor for 400 mm sweepcomplete all as specified and directed by Engineer-in-Charge. |
| 96 | S&F in replacement of Exhaust fan 10\"/12\" sweepcomplete all as specified and directed by Engineer-in-Charge. |
| 97 | S&F in replacement of PVC Exhaust fan 300MM sweepcomplete all as specified and directed by Engineer-in-Charge. |
| 98 | M&L for servicing,Taking down ceiling fan 56\"/48\" sweep removing cleaning of dust, properly cleaning greasing of bearing including replacing and painting connecting up complete all as specified and directed by Engineer-in-Charge. |
| 99 | Supply and fixing capacitor, capacity 2.5 mfd in replacement complete all as specified and directed by Engineer-in-Charge. |
| 100 | Supply and fixing capacitor, capacity 3.15 mfd in replacement complete all as specified and directed by Engineer-in-Charge. |
| 101 | M&L for rewinding of burnt ceilingfan motor 1200/1400 mm sweep with super enamelled copper winding wire of suitable guage as per details of anymake /model complete all as specified and directed by Engineer-in-Charge. |
| 102 | Supply and replacement of ball bearingof ceiling fan of any size complete all as specified and directed by Engineer-in-Charge. |
| 103 | Supply and fixing and connecting flexible copper twisted twin core of size 23/00076 complete all as specified and directed by Engineer-in-Charge. |
| 104 | Supply and replacement of gun metal bush of any type/make/size complete all as sepecified and directed by Engr -in-Charge. |
| 105 | Supply and replacement of rubber real complete all as specified and directed by Engineer-in-Charge. |
| 106 | Supply and replacement of U Clamp complete with nuts, bolts, pins. Heavy dutycomplete all as specified and directed by Engineer-in-Charge. |
| 107 | Supply and fixing nuts,bolts, washers and spilt pins for ceiling fancomplete all as sepecified and directed by Engr -in-Charge |
| 108 | S&F stepped type electronic fan regulator flush type 230 Volts , AC complete all as specified and directed by Engineer-in-Charge. |
| 109 | S& F AC plug to of 20 Amp, 3 Pin suitable for AC Box (sheet metal enclosure with a two pin and earth plug and socket ) 230 Volts , AC complete all as specified and directed by Engineer-in-Charge. |
| 110 | S& F AC socket of 20 Amp, 3 Pinsuitable for AC Box (sheet metal enclosure with a two pin and earth plug and socket ) 230 Volts , AC complete all as specified and directed by Engineer-in-Charge. |
| 111 | Supply, installation , commissioning and testingof LTPanel Boardout door type factory made out of CRCAsheet 3.15 mm thick dust & vermin proof , frontand rear openingshutters having locking arrangementtotally enclosed weather proof, antirusted powder coated including aluminium Bus Barof 400 Ampsrating of suitable length, 440 volts, 3 Phase 4 wire50 Hz mountedon suitable type ofinsulators.complete withbottom removable gland plates, as required, all internalconnection wiring bymin. 2.5 Sqmm. copper wires, Panel shall be comprising ofseperate chambers / modules / compartment to accomodate incomer MCCB, outgoing MCCB andinstrument chamber comprise of digital Ammeter & voltmeter flush mounted, selector switches, RYB indicator ,CT\"s,etc complete mounted on suitable size of MS angle framestandof minimum 450 cmheight from ground l;evelinclPCCand earhwork required to fix the stand , The panel board shall be comprising of the following :-(a) Incommer - MCCB 4 POLE 415 V 400 A (35 kA)- 02 Nos(b) 3 ph digital KWH meter -01 NosOutgoing :-(b) ON load Change over Switch 400 Amps 4 Pole -01 Nos (c)MCCB 4 POLE 415 V125 A (25 kA)- 04 Nos(d ) MCCB 4 POLE 415 V63 A (25 kA)- 03 Nos(e) Blank chamber - 01 Nos with din rail sutable for fixing03 Nos TP/TPN MCBs |
| 112 | S&F in replacement of outdoor type LED flood light 70 watt fitting aesthetically designed for road lighting, having secondary optics with uniform distribution of light. Pressure die cast aluminum housing powder coated in grey and toughened glass, IP 66 protection, class I with seperate driver and operating voltage range 120 to 270 V including suitable fixing arrangment complete all as specified and directed by Engineer-in-Charge. |
| 113 | Supply and fix as in repair o f45W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance.LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall havepower factor more than 0.95. complete all as specified and directed by Engineer-in-Charge. |
| 114 | Supply and fixing in replacement of LED post top 20 W in made in die-cast aluminium housing with decorative clear opal acrylic diffuser IP 65 protection, warm white , 240 Volts AC, 50 Hz, incl make proper connection complete including cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed by Engineer-in-Charge. |
| 115 | S&F Busbar Chambersuitable size forset of 04 aluminium busbar 400 Amps rating ,supported with suitable size as per direction, each of heavy duty porcelin stand lock with suitable sizeof brass nut, bolts and washer with heat shrinkable PVC sleeving.The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral, The Chambershall be fixed30 cm above the normal ground level complete with PCC foundation (1:2:4 )type B2complete all as specified and directed by Engineer-in-Charge. |
| 116 | S & F in replacement of hot pressedmoulded SMC boxes with hinged door fixing of size 325mm x 220 mmx 150 mm with MS clamp 25 x 3mm made to shape with necessry nuts bolts clamps and washers complete comprising of Aluminium bus bar 63 Amps capacity of suitable size -04 nos mounted over Porcelain insulator with nuts & bolts washers incl MCB SP 6 amps and making incoming and outging connections by taking out loops of cable of any size incl necesary excavations and other civil worksMake :- Sintex /Universal/ SMS complete |
| 117 | S & F Earthing completewith galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground vertically to a depth not less than 2.25 meters deep below ground levelwith top edge of the plate not less than 1.5 Mtrs below normal ground level connect to galvanized ironearthstrip 25 x 4mm as earth leadby means of bolts, nuts, check nuts and washers of galvanized iron or steel up to 7.5 meter length connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC cover 1:2:4 mix with 6mm dia nominal reinforcement @ 150mm c/c both ways etc completeall as shown in electrical plate No 3, connected to earthing test point complete including testing on complete all as specified and directed by Engineer-in-Charge. |
| 118 | S&F in replacement of Socket type aluminum lugs of 400 Sqmm by disconneting the cables removing the old unserviceble ones and replacing complete all as specified and directed by Engineer-in-Charge. |
| 119 | All as per item No 118 above but Socket type aluminum lugs 240 Sqmm |
| 120 | All as per item No 118 above but Socket type aluminum lugs 120 Sqmm |
| 121 | All as per item No 118 above but Socket type aluminum lugs 95 Sqmm |
| 122 | All as per item No 118 above but Socket type aluminum lugs 70 Sqmm |
| 123 | All as per item No 118 above but Socket type aluminum lugs 50 Sqmm |
| 124 | All as per item No 118 above but Socket type aluminum lugs 35 Sqmm |
| 125 | All as per item No 118 above but Socket type aluminum lugs 25 Sqmm |
| 126 | All as per item No 118 above but Socket type aluminum lugs 16 Sqmm |
| 127 | Supply and fixing in replacement ofceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 245 CFM with service . Five star rated complete all as specified and directed by Engineer-in-Charge.Note:- OLD fan need to deposit in MES store no credit will be provided for the same. |
| 128 | M&L forDisconnecting / taking down / dismantling Solar flat plate collectorof 100/125 LPD capacity for servcing , cleaning and repairing, brazing oftubescomplete and reassembling the same after repair complete all as specified and directed by Engineer-in-Charge. |
| 129 | M & L for De-scaling, cleaning of hot water and cold water tanks incl heat collecting units with heat absorbing sheet etc of solar heating system of capacity 500 LPD complete all as specified and directed by Engineer-in-Charge. |
| 130 | Supply and fixingin replacement electric Heating element 3 KW( for solar water heater)with thermostat for electrical Back up complete all as specified and directed by Engineer-in-Charge. |
| 131 | Supply and Install SS Hot Water Tank of Capacity 500 Ltrs ( suitable for existing) double wall insulated with PUF Insulation machine injectedinner shell SS 316 and Outer Shell SS 304 Stucco Aluminium alloy coated coloured steel complete on roof tops at aheight of 7 ftincl connection of inlet and outlet water connections complete all as specified and directed by Engineer-in-Charge. |
| 132 | M&L for hot water pipe duly insulated with glass wool and aluminium cladding20 mm bore including taking down complete all as specified and directed by Engineer-in-Charge. |
| 133 | M&L for hot water pipe duly insulated with glass wool and aluminium cladding25 mm bore including taking down complete all as specified and directed by Engineer-in-Charge. |
| 134 | M&L forreplacement of Gunmetal gate valve with iron wheel head screwed both ends for iron pipe and fixed 25 mm dia including taking down complete all as specified and as directed by Engr in Charge |
| 135 | M&L for replacement of Gunmetal gate valve with iron wheel head screwed both ends for iron pipe and fixed 20mm dia including taking down complete all as specified and directed by Engineer-in-Charge. |
| 136 | M&L for replacement of unservicable parts of solar water heater complete with servicable partsand making it servicable complete testing and commsioning and brazing of tanks for arrresting leakages complete all as specified and directed by Engineer-in-Charge.Note : parts will be measured here after as supply only. |
| 137 | S&F following items for solar water heater 500 LPD complete all as specified and directed by Engineer-in-Charge. |
| 138 | Absorber Plate made of copper sheet, laser or ultrasonically welded to copper tubes ( Solar flat plate collector as per existing type) with FlangesL-1860 W-1240 H-100, weight 35-42 kg working pressure 490 KPA complete all as specified and directed by Engineer-in-Charge. |
| 139 | Single pane 3.2 mm tempered low iron glass collector as per existing size and type complete all as specified and directed by Engineer-in-Charge. |
| 140 | Supply & install 500 Ltr Cold water Tank of material SS-304( as per existing type) with Manhole & Stand complete all as specified and directed by Engr-in-charge. |
| 141 | Supply & install Makeup Tank for heat exchanger of 5 Liter with ball cock complete all as specified and directed by Engineer-in-Charge. |
| 142 | Supply & install Back Plact Collector complete all as specified and directed by Engineer-in-Charge. |
| 143 | M & L for Servicing of OLD/ UNSV -SOLAR street light fittingincluding servicing and Cleaning of solar panel , Low maintenance tubular batteryby filling of Distilled water and first charging including replacement of damaged battery terminals, securingof all electrical wire circuit and connections, reparing of damaged foundation complete all as specified and directed by Engineer-in-Charge.Note:- 1. All type of T & P, Distilled water, control cable upto battery terminal, PCC, ladder & tripod etc required at site will be arranged by the contractor and rates for the same will be deemed to be included in the quoted rate. (Spares required to make functional of solar light shall be measured and paid seperately under relevent items ) |
| 144 | Spares of Solar security light complete all as specified and directed by Engineer-in-Charge. |
| 145 | All as per item No 144 above butReplacement of Solar PV Module 74W( As per existing ) |
| 146 | All as per item No 144 above butReplacement of White LED based light source 12W( As per existing ) |
| 147 | All as per item No 144 above butReplacement of Driver of solar street Lights( As per existing ) |
| 148 | All as per item No 144 above but Replacement of Battery rating of 12V & 100 AH( As per existing ) |
| 149 | Supply & fixbattery compartment box made up of MS sheet 2mm thick size suitable for battery with MS cover, locking arrangements & fixing accessories with inside weather proof coated & out side Aluminium paint incl writing pole number in black colour paint etc complete all as specified and directed by Engineer-in-Charge. |
| 150 | S & F in replacement of Integrated all in one Solar Street light (Inbuit Solar PV module and Lithium battery ) 24 watt, secondary optics, LED driver efficiency>92%, battery type LiFePO-04, IP66, colour temperature 6000K-6500K , 140 Lumens per watt Auto On/Off, overcharging protection incl taking down old unser and complete fixing and connection complete all as specified and directed by Engineer-in-Charge. |
| 151 | Servicing of DG Set 160 KVA of anyMake ,checking entire system as per manufacturer\"s catalogue such aschecking all parts for serviceability, taking down defective parts such as fuel filter assembly, by pass filter assembly, lube oil filter assembly, air cleaner assembly lube oil hose flexible pipe, hose turboetc including replacement the same with same size, make and capacity of parts Such as Fuel filter, Lube oil filter, Air filter, coolant and Engine oil ,hose pipe,Diesel filter with gasketetc and draining out the old used burnt engine oil from the oil sump and cleaning oil sump with suitable cleaning solution such as petrol and diesel or anyother cleaning solution and refilling new engine oil required grade up to required level and including checking of AMF control panel, tightening of loose connections and testing to DG Set to the entire satisfaction of the Engineer-in-ChargeNote :(i)Engine oilshall be measured and paid for separately under successive items here-in-after. However, labour charge are deemed to be included in item rate above.(ii) Servicing shall be carried out by authorised dealer of manufacturer.(iii) Minimum 6 months gap/200 Hrs of run whichever is earlier shall be considered for next service.(iv) Repair Guarantee forreplaced parts/servicing ofDG Set shall be for six month from the date of service. |
| 152 | All as per item No 151 above but DG set of capacity 75 KVA |
| 153 | All as per item No 151 above but DG set of capacity 62.5 KVA |
| 154 | All as per item No 151 but DG set of capacity 30KVA |
| 155 | All as per item No 151 above but DG set of capacity 20 KVA |
| 156 | S & F for Fan belt set suitable as per existing for 15 kVA to 200 kVA DG Setof any type any makecomplete all as specified and directed by Engineer-in-Charge. |
| 157 | S& F in repair for New dehydrated Engine oil as required grades suitable as per existing for 15 kVA to 200 kVA DG Set of any type any makecomplete all as specified and directed by Engineer-in-Charge.Note : Engine oil will be suppied in manufacturer sealed barrel |
| 158 | Taking down of radiator from DG set (20 kVA to 160 kVA DG) of any type any make carefully cleaning of tubes and fins complete with thehelp of proper cleaning agent and wire brush soldering of tubes and fins at required places testing and refilling complete all as specified and directed by Engineer-in-Charge. |
| 159 | Taking down of defective water pump from DG set(20 kVA to 160 kVA DG) of any type any make repair the same bywater pump repair kit removing of leakage refitting after testing complete all as specified and directed by Engineer-in-Charge. |
| 160 | M&L for repairof water pump body assemblysuitable for 1 (20 kVA to 160 kVA DG)DG Set of any type any make complete all as specified and directed by Engineer-in-Charge. |
| 161 | M&L for repairof self starter motor and charging alternator 24 volts complete set incl dismantling and taking down old unser from DG setsuitable for(20 kVA to 160 kVA DG)DG set of any make any type complete all as specified and directed by Engineer-in-Charge. |
| 162 | M&L for repairof self starter motor and charging alternator 12 volts complete set incl dismantling and taking down old unser from DG setsuitable for(20 kVA to 160 kVA DG) DG set of any make any type complete all as specified and directed by Engineer-in-Charge. |
| 163 | S&F in replacement of solenoid switch suitable for existing DG including all necessary arrangement for kirloskar CUMMINS Gen set of capacity(20 kVA to 160 kVA DG) complete all as specified and directed by Engineer-in-Charge. |
| 164 | Supply only distilled water of best quality in 05 litrs sealed gallon packing complete all as specified and directed by Engineer-in-Charge. |
| 165 | M&L for servicing of AMF panel of DG set of capacity upto to 160 KVA cleaning of AMF panel, rectification of defect rewiring replacement of D/S indicator with new indicator of complete AMF panel and replacement of U/S relays under respective item of this schedule complete all as specified and directed by Engineer-in-Charge. |
| 166 | All as per item No 165above herein but DG Set of capacity above 30 KVAand upto 160 KVA complete all as specified and directed by Engineer-in-Charge. |
| 167 | M&L for Replacement to unserviceable batteries of 12 volts180 AH with new batteries of 12 volts 180 AH maintenance free complete all as specified and directed by Engineer-in-Charge.Note: Rate for initial charging are included in unit rate |
| 168 | Supply & fix Automatic voltage regulator relay 415V AC complete all as specified and directed by Engineer-in-Charge. |
| 169 | Supply & fixElectronic timer 240V AC, adjustment time 6-120Sec complete all as specified and directed by Engineer-in-Charge. |
| 170 | Supply & fix reverse power relay, 415V AC complete all as specified and directed by Engineer-in-Charge. |
| 171 | S&F PVC insulate copper heavy duty 1 mtr long as battery lead suitable for batteries of capacity 24V 180AH complete all as specified and directed by Engineer-in-Charge. |
| 172 | S&F in replacement of digital multi function meter to read voltage current and power factor including set of CT-1 each complete all as specified and directed by Engineer-in-Charge. |
| 173 | S&F in replacement of indicating lamp RYB complete all as specified and directed by Engineer-in-Charge. |
| 174 | S&F in replacement of Auto manual switch complete all as specified and directed by Engineer-in-Charge. |
| 175 | S&F in replacement of push button switch red with element complete all as specified and directed by Engineer-in-Charge. |
| 176 | S&F in replacement of push button switch green with element complete all as specified and directed by Engineer-in-Charge. |
| 177 | S&F in replacement of 3 pole power contactor LT MNX 95 CONTcomplete all as specified and directed by Engineer-in-Charge. |
| 178 | S&F in replacement of 3 pole power contactor LT MNX 140 CONT complete all as specified and directed by Engineer-in-Charge. |
| 179 | S&F in replacement of 3 pole power contactor LT MNX 225 CONTcomplete all as specified and directed by Engineer-in-Charge. |
| 180 | S&F in repair of Autocut Electrical Battery Charger 12V DC, 5 Amp Unit SMPS with Constant Voltage Output with Battery Charging Transformer and Moulded Type Rectifier Unit etc complete all as specified and directed by Engineer-in-Charge. |
| 181 | All as per item No 180 above but Battary Charger 24V DC, 10 Amp complete all as specified and directed by Engineer-in-Charge. |
| 182 | M&Lfor Providing,PCC 1:3:6 type C-1 using 20 mm graded stone aggreat,for damaged earth pit chamber with fair finish internal surface of concrete chamber of earth complete all as specified and directed by Engineer-in-Charge. |
| 183 | S&F in replacement of80 mm thick PCC pit cover 320 mm x 320 mm of PCC 1:2:4 TYPE B-1 using 20 MM graded stone aggregate including necesssary form work and handle for removing the cover from pit with fair finish complete all as specified and directed by Engineer-in-Charge. |
| 184 | S&F in replacement of Ceramic insulator of standard size for ligthning strip protection fixed in wall of one mtr distance with suitable size screws complete all as specified and directed by Engineer-in-Charge. |
| 185 | S&F in replacement Copper strip 20 x 3.0 mm fixed with top of insulator/saddles, fixing with screws , washer etc with help of drill machine for roof conductors and down conductors above ground and and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engineer-in-Charge. |
| 186 | S&F in replacement for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by Engineer-in-Charge. |
| 187 | Material and Labour for preparing surfaces of DG set of capacity up to 200 KVA by rubbing old paint and applying two coats of spray painting with (existing colour)deco paintfrom outside, complete all as specified and directed by Engineer-in-Charge.Note.(i)Painting of DG will be carried out for plinth mountedDG set .Necessary tools and plants shall be arranged by the contractor.(ii) MES No / SM No has to be written with 3\" letters on each DG set after painting with white colour on black background without any extra cost. |
| 188 | Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed by Engineer-in-Charge. |
| 189 | Returning, filling, including spreading levelling and well ramming in layers not exceeding 25cm apart complete all as specified and directed by Engineer-in-Charge. |
| 190 | Removing of surplus excavated soil to a distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 191 | M&L for sand cushoning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed by Engineer-in-Charge. |
| 192 | M&L for sub class `B` bricks for cable protection complete all as specified and directed by Engineer-in-Charge. |
| 193 | Taking down UNSV LT Under Ground cable of any size complete all as specified and directed by Engineer-in-Charge. |
| 194 | Supply and laying, connecting and testing XLPE underground cableinsulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 sqmm 4 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on walletc complete all as specified and directed by Engineer-in-Charge.Note:(i) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highwaysand Aluminium thimbles/lugs are incl in the quoted rates. (ii) All equipments , machinery or toolsif required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost. |
| 195 | All as per item No 194 above but for 3.5 core 25 Sqmm. |
| 196 | All as per item No 194 above but for 3.5 core 70 Sqmm. |
| 197 | All as per item No 194 above but for 3.5 core 95 Sqmm. |
| 198 | Supply& fixing in replacement MCCBTPN 200 Amps 415 Volts 36 kA complete all as specified and directed by Engineer-in-Charge. |
| 199 | Supply& fixingin replacement MCCBTPN 400 Amps 415 Volts 36 kA complete all as specified and directed by Engineer-in-Charge. |
| 200 | S&F on load Change Over switch 415V in sheet metal enclosures 4 pole of capacity 320 Amps 415 Voltinclmaking suitable arrangement to fix on wall/panel as required complete all as specified and directed by Engineer-in-Charge. |
| 201 | Supplying, erecting, testing and commissioning of Microprocessor based AMF panel suitable for diesel generating set of 30 KVA capacity three phase 415 Volts, 50 HZ AC including internal wiring with suitable copper conductor with thimbles, timer, relay, MCB 6 Nos- 10 Amps, VMR 3 pole - 02 Nos, battery charger 12 V - 01 No, Motorised changeover switch CX3 100 Amps, Volt meter/Ammeter, RYB phase indicators(DG and Mains), selector switchs etc including fixing with PCC work in floor alongwith suitable angle iron frame for AMF panel complete with all standard features, safeties etc., complete all as specified and directed by Engineer-in-Charge. |
| 202 | Supply and fixing in repair of Earth continuity strip or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or fixed on wall with porcelain insulator or any other indicated situation for loop earthing etc. as required 25x4 mm GI strip complete all as specified and directed by Engineer-in-Charge. |
| 203 | Supplying, erecting, testing and commissioning of Microprocessor based AMF panel suitable for diesel generating set of 62.5 KVA capacity three phase 415 Volts, 50 HZ AC including internal wiring with suitable copper conductor with thimbles, timer, relay, MCB 6 Nos- 10 Amps, VMR 3 pole - 02 Nos, battery charger 12 V - 01 No, Motorised changeover switch CX3 160 Amps, Volt meter/Ammeter, RYB phase indicators(DG and Mains), selector switchs etc including fixing with PCC work in floor alongwith suitable angle iron frame for AMF panel complete with all standard features, safeties etc., complete as directed and specified by Engineer in Charge. |
| 204 | M & L for Taking out unserviceable indoor unit and supply and fix the newindoor unit of 1.5/2 TR capacity split AC 230 Volts single phase including installing ,charging complete all as specified and directed by Engineer-in-Charge.Note:- OLD U/S AC indoor unit need to deposit in MES store no credit will be provided for the same |
| 205 | M & L for Taking out unserviceable outdoor unitand supply and fix the newoutdoor unit of 1.5/2 TR capacity split AC 230 Volts single phase including installing ,charging complete all as specified and directed by Engineer-in-Charge.Note:- OLD U/S AC Outdoor unit need to deposit in MES store no credit will be provided for the same |
| 206 | Supply, installation , commissioning and testingof LTPaneloutdoor type factory made out of CRCAsheet 3.15 mm thick dust & vermin proof , frontand rear openingshutters having locking arrangementtotally enclosed weather proof, antirusted powder coated including aluminium Bus Barof 400 Ampsrating of suitable length, 440 volts, 3 Phase 4 wire50 Hz mountedon suitable type ofinsulators.complete withbottom removable gland plates, as required, all internalconnection wiring bymin. 2.5 Sqmm. copper wires, Panel shall be comprising ofseperate chambers / modules / compartment to accomodate incomer MCCB, outgoing MCCB andinstrument chamber comprise of digital Ammeter & voltmeter flush mounted, selector switches, RYB indicator ,CT\"s,etc complete mounted on suitable size of MS angle framestandof minimum 450 cmheight from ground l;evelinclPCCand earhwork required to fix the stand , The panel board shall be comprising of the followingcomplete all as specifiedand directed by Engineer-in-Charge.(a) Incommer - MCCB 4 POLE 415 V 250 A (35 kA)- 01 NosOutgoing :-(a)MCCB 4 POLE 415 V100 A (25 kA)- 02 Nos(b ) MCCB 4 POLE 415 V63 A (25 kA) - 04 Nos(c)Blank chamber - 01 Nos with din rail sutable for fixing04 Nos TP/TPN MCBs(d) Digital ammeter 0-500 A flush type square with selector switch & CTs -01 No(e) Digital voltmeter 0-500 V flush type square with selectorswitch-01 No |
| 207 | Supplying, erecting, testing and commissioning of Microprocessor based AMF panel suitable for diesel generating set of 75 KVA capacity three phase 415 Volts, 50 HZ AC including internal wiring with suitable copper conductor with thimbles, timer, relay, MCB 6 Nos- 10 Amps, VMR 3 pole - 02 Nos, battery charger 12 V - 01 No, Motorised changeover switch CX3 200 Amps, Volt meter/Ammeter, RYB phase indicators(DG and Mains) and selector switchs etcincluding fixing with PCC work in floor alongwith suitable angle iron frame for AMF panel complete with all standard features, safeties etc., complete all as specified and directed by Engineer-in-Charge. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail