}

Dr.B.R.Ambedkar Memorial Hospital Raipur (C.G.) Invites E-Tender For Supply Of Implant Cardiology Dept. Item On Rate Contract Basis To Hospital For A Period Of One Year. Tender Document Containing The Detailed Terms Conditions May Be Viewed And Obtained F, raipur-Chhattisgarh

Health Department has published Dr.B.R.Ambedkar Memorial Hospital Raipur (C.G.) Invites E-Tender For Supply Of Implant Cardiology Dept. Item On Rate Contract Basis To Hospital For A Period Of One Year. Tender Document Containing The Detailed Terms Conditions May Be Viewed And Obtained F. Submission Date for this Tender is 08-07-2024. Medical Diagnostic x ray Products Tenders in raipur Chhattisgarh. Bidders can get complete Tender details and download the document.




Tender Notice

43780537
Dr.B.R.Ambedkar Memorial Hospital Raipur (C.G.) Invites E-Tender For Supply Of Implant Cardiology Dept. Item On Rate Contract Basis To Hospital For A Period Of One Year. Tender Document Containing The Detailed Terms Conditions May Be Viewed And Obtained F
Open Tender
Indian
Chhattisgarh
Raipur
08-07-2024

Tender Details

Dr.B.R.Ambedkar Memorial Hospital Raipur (C.G.) Invites E-Tender For Supply Of Implant Cardiology Dept. Item On Rate Contract Basis To Hospital For A Period Of One Year. Tender Document Containing The Detailed Terms Conditions May Be Viewed And Obtained From Https://Eproc.Cgstate.Gov.In-RIGHT HEART CATHETERISATION + LEFT HEART CATHETERISATION BALLOON MITRAL VALVOTOMY PULMONARY BALLOON VALVOTOMY ASD DEVICE CLOSURE VSD DEVICE CLOSURE PDA DEVICE CLOSURE RENAL ANGIOPLASTY LAA DEVICE CLOSURE PACEMAKER VVIR MRI PACEMAKER DDDR MRI IMPLANTABLE CARDIOVERTER DEFIBRILATOR (Single Chamber MRI )/ (Dual Chamber MRI ) CARDIAC RESYNCHRONISATION THERAPY - Pacing BIPOLAR MRI/ QUADRIPOLAR MRI CARDIAC RESYNCHRONISATION THERAPY DEFIBRILATOR BIPLOAR MRI/ QUADRIPOLAR MRI Physiological pacing (Left bundle branch pacing) kit with VVIR MRI Physiological pacing (Left bundle branch pacing) kit with DDR MRI Pericardiocentesis PERIPHERAL ANGIOPLASTY (BALLOON MOUNTED STENT) PERIPHERAL ANGIOPLASTY (SELF EXPANDING STENT) Mitra Clip Procedure Carotid Stent BALLOON ATRIAL SEPTOSTOMY TRANSCATHETER AORTIC VALVE IMPLANTATION (TAVI) TRANSCATHETER AORTIC VALVE IMPLANTATION (TAVI) CORONARY ANGIOPLASTY with the Help of Drug Eluting Balloon Without Stent Paravalvular Leak Closure IABP VT Ablation 1 VT Ablation 2 PSVT AF Ablation INTRODUCER SHEATH 8,9,10,F FEMORAL Atraumatic tapered tip, enhanced pushability and flexibility,Hemostatic valve maintains uncompromised haemostasis to avoid bleeding and air aspiration, enlarged inner diameter for ultra smooth transition between dilator and sheath, lubricant coating, Metallic puncture needle with mini J tipped PTFE guide wire. Length 11cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, pyrogenicity and shelf life should be provided. Annual turnover of manufacturer should be over 2 crore. INTRODUCER SHEATH FEMORAL Atraumatic tapered tip, enhanced pushability and flexibility,Hemostatic valve maintains uncompromised haemostasis to avoid bleeding and air aspiration, enlarged inner diameter for ultra smooth transition between dilator and sheath, lubricant coating, Metallic puncture needle with mini J tipped PTFE guide wire. Length 23cm. All Sizes. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, pyrogenicity and shelf life should be provided. Annual turnover of manufacturer should be over 2 crore. CONTROL SYRINGE Control syringes latex free specially designed for ease of use. The plunger tip and barrel are designed for consistent movement and smooth rotator action. The enhanced graduation markings increase legibility. The clear polycarbonate design allows for enhanced visual inspection and the enlarged reservoir stop is specially designed to decrease the possibility of air infusion. Create smooth feel during injection, Clear Barrel : Provides clarity and smooth as glass feel, Solid Plunger Body : Maintains stability and durability under pressure, Rotating luers. Intended to minimize the potential of air bubbles introduced into the catheter.10 ml Dose control syringe, 12 ml Dose control syringe, 20 ml Dose control syringe. PRESSURE MONITERING LINE 150-200CM ClearTubo Pressure Monitoring Line is made up of High quality medical grade pvc tubing, it helps to reduces the risk of kinking. It comes with a choice of either male to male or male to female luer locks . The pressure range of this line is more than or equal to 1000 psi. The Length ranges from 150 cm to 300 cm. Small bore pressure line helps to get accurate pressure transmission to the ClearCaths tip & ClearGuides tip, Kink resistant medical grade PVC tube, does not bulge even at high pressure, Male and female luer locks help to ensures secure connection, E.T.O. Sterile, High degree of safety and low toxicity, Multi end adapter option, compatible with different specifications. CORONARY DIGNOSTIC CATHETER: JL 5Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: JL 6 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. CORONARY DIGNOSTIC CATHETER: JR 4.5Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. CORONARY DIGNOSTIC CATHETER: JR 5 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. CORONARY DIGNOSTIC CATHETER: JR 6 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: AL 0.75Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: AL 1 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: AL 2Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: AL 3 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: AR 1 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. CORONARY DIGNOSTIC CATHETER: AR 2Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: AR 3 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: Multipurpose A Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. CORONARY DIGNOSTIC CATHETER: Multipurpose BLarge inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: IMA Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. CORONARY DIGNOSTIC CATHETER: NIHLarge inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: SonesLarge inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: Sones with side holesLarge inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: Cobra 1 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr.Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. CORONARY DIGNOSTIC CATHETER: Cobra 2 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr.Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: Cobra 3Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: Simmons 1Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: Simmons 2Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: Simmons 3Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. CORONARY DIGNOSTIC CATHETER: Headhunter 1Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr . Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: Headhunter 2 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. CORONARY DIGNOSTIC CATHETER: Headhunter 3 Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: Renal Double CurveLarge inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: Vitek Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: Hockey Stick Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: SidewinderLarge inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: Cournand Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: VertebralLarge inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: RCB Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: LCB Large inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: SRCLarge inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. CORONARY DIGNOSTIC CATHETER: Renal Diagnostic CatheterLarge inner lumen, Hub catheter joint should be durable, Catheter Length: 100 - 110 cm, Sizes 4/5/6/7 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. TIGER SHAPE CATHETER (Radial)The high flow of the catheter allows for more contrast into the vessel that results in a clear, bright angiogram. Your diagnosis and treatment planning is enhanced. Quick, Safe Vessel Engagement: polymer material and full length double braiding provides excellent push ability and efficient torque transmission for outstanding handling. Soft atraumatic tip designed to reduce potential for vessel trauma. Wide variety of curve styles for all possible anatomies. Used in Angiography for Cardiac patients and are designed to deliver radiopaque cont ast medium to selected sites in the vascular system. Shape Retention property. Available in 5F and 6F. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: JL 3Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: JL 3 with SideholeDistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications:JL 3.5Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications:JL 3.5 with SideholeDistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications:JL 4Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications:JL 4 with SideholeDistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: JL 4.5Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: JL 4.5 with SideholeDistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: JL 5Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: JL 5 with SideholeDistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: JL 6Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: JL 6 with SideholeDistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: JR 3Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: JR 3 with sideholeDistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: JR 3.5Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: JR 3.5 with sideholeDistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: JR 4Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: JR 4 with sideholeDistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: JR 4.5Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: JR 4.5 with sideholeDistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: JR 5Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: JR 5 with sideholeDistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: JR 6Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: JR 6 with sideholeDistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: AL 0.75 (Short tip and Standard tip)Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: AL 0.75 with sidehole (Short tip and Standard tip)Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: AL 1 (Short tip and Standard tip)Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: AL 1 with sidehole (Short tip and Standard tip)Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: AL 2 (Short tip and Standard tip)Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: AL 2 with sidehole (Short tip and Standard tip)Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: AR 1 (Short tip and Standard tip)Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: AR 1 with sidehole (Short tip and Standard tip)Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: AR 2 (Short tip and Standard tip)Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: AR 2 with sidehole (Short tip and Standard tip)Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: Extra Backup 3 for Right & Left CoronaryDistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: Extra Backup 3.5 for Right & Left CoronaryDistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: Extra Backup 4 for Right & Left CoronaryDistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: Extra Backup 5 for Right & Left CoronaryDistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: Extra Backup 3 for Right & Left Coronary (With Sidehole)Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Extra Backup 3.5 for Right & Left Coronary (With Sidehole)Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: Extra Backup 4 for Right & Left Coronary (With Sidehole)Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: Extra Backup 5 for Right & Left Coronary (With Sidehole)Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: Any Other Type Of Extra Backup Coronary Guide Catheter/ Specialized Shape Guiding CatheterDistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: IMADistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: Hockey StickDistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: Multipurpose 1 Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: Multipurpose 2 Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: Right Coronary BypassDistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: Renal Guide CatheterDistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: Head HunterDistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: Left Coronary BypassDistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guiding Catheter Specifications: Any Other TypeDistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: 100 - 110 cm, Sizes 4/5/6/7/8 Fr. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Femoral Guiding Catheter Specifications:Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: ≥ 120 cm, Sizes 4/5/6/7/8 Fr for all available curves. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Femoral Guiding CatheterSpecifications:Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Catheter Length: < 100 cm, Sizes 4/5/6/7/8 Fr for all available curves. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Dedicated Radial Guiding CatheterSpecifications:Distal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., Hydrophilic coating, Sizes 4/5/6/7/8 Fr for all available curves, Single Radial Guiding catheter for left and right system. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guide catheter for CarotidDistal tip Radio opaque marker, Large inner lumen, Encapsulated metallic wire braid provides better lumen and kink resistance properties, Flexible primary curve for active engagement and strong secondary curve for backup support, Stiffer shaft, Lubricious and non thrombogenic coating both outside and inside.., All Sizes. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Guide Extension CatheterHydrophillic Coating, Soft Polymer Tip, With Radiopaque marker. All Sizes. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Angiographic Guide WireAngiographic Guide Wire, PTFE coated, Straight tip, 0.021, Length: 120-180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Angiographic Guide WireAngiographic Guide Wire, PTFE coated, J tip, 0.021, Length: 120-180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Angiographic Guide WireAngiographic Guide Wire, PTFE coated, Straight tip, 0.021, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Angiographic Guide WireAngiographic Guide Wire, PTFE coated, J tip, 0.021, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Angiographic Guide WireAngiographic Guide Wire, PTFE coated, Straight tip, 0.025, Length: 120-180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Angiographic Guide WireAngiographic Guide Wire, PTFE coated, J tip, 0.025, Length: 120-180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Angiographic Guide WireAngiographic Guide Wire, PTFE coated, Straight tip, 0.025, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Angiographic Guide WireAngiographic Guide Wire, PTFE coated, J tip, 0.025, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Angiographic Guide WireAngiographic Guide Wire, PTFE coated, Straight tip, 0.032, Length: 120-180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Angiographic Guide WireAngiographic Guide Wire, PTFE coated, J tip, 0.032, Length: 120-180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Angiographic Guide WireAngiographic Guide Wire, PTFE coated, Straight tip, 0.032, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Angiographic Guide WireAngiographic Guide Wire, PTFE coated, J tip, 0.032, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Angiographic Guide Wirengiographic Guide Wire, PTFE coated, Straight tip, 0.035, Length: 120-180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Angiographic Guide WireAngiographic Guide Wire, PTFE coated, J tip, 0.035, Length: 120-180 cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Angiographic Guide WireWire, PTFE coated, Straight tip, 0.035, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore. Angiographic Guide WireAngiographic Guide Wire, PTFE coated, J tip, 0.035, Length: 260-300cm. Clinically used for minimum 10 years for minimal invasive diagnostic or therapeutic procedures. Detailed data for flexibilty, Kink Test, coating integrity, Torque strength, pyrogenicity and shelf life should be provided. Annual turnover of manufacturers should be over 2 crore.

Key Value

Document Fees
INR 1000 /-
EMD
INR 100000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail