Tender For Supply Installation And Commissioning Of Various Instruments For Chemical Laboratory To Analysis Of Various Parameter Of Water And Flue Gasses At Ctpp-O&M, Chhabra, Chhabra-Rajasthan
TDR : 43780118
Tender Notice
Corrigendum Details
BOQ
Expired
Chhabra
Rajasthan
Corrigendum : Tender For Supply Installation And Commissioning Of Various Instruments For Chemical Laboratory To Analysis Of Various Parameter Of Water And Flue Gasses At Ctpp-O&M, Chhabra
Name of Work: Supply Installation and Commissioning of various Instruments for Chemical laboratory to analysis of various parameter of water and Flue gasses at CTPP-O&M, Chhabra
Sl. No.
Item Description
1
Dissolve Oxygen Meter 1) Accuracy: ± 0.8 ppb or ± 2 %2) Application: Industrial3) Battery Life: Rechargeable battery, Lithium Ion, 10 hours of continous use4) Certifications: LVD IEC/EN 61010-1, EMC IEC/EN 61326-1 & Ecodesign Directive5) Communication: Data monitoring per RS232 Data/configuration transfer per USB key6) Communication Capabilities: RS232 - USB Key7) Connections: 6 mm (¼\")8) Data Storage: 5700 measurements9) Dimensions (H x W x D): 200 mm x 170 mm x 190 mm10) Display: TFT colour 72 x 54 mm11) Includes: 3100 instrument, external power supply, US power plug, 3 m inlet tubing, tool kit12) Lower Limit of Detection (LOD): 0.6 ppb13) Material: Enclosure: Stainless steel, IP66 with polycarbonate sides14) Operating temperature range: -5 - 45 °C15) Parameter: Oxygen16) Power Options: US Power Cord17) Range: 0 - 2000 ppb18) Response time: < 15 s19) Sample Interval: 5 - 60 s20) Sample Pressure: 0 - 10 bar21) Sample Temperature: -5 - 45°C (41 - 113°F)22) Tube Connection: 1/4 in23) Units: ppb, ppm, wt %, mg/L, O2 %, mbar and more24) Wall Thickness: 1/4 in25) Warranty: 12 months26) Weight: < 3.5 kg27) What\"s included: 3100 instrument, external power supply, US power plug, 3 m inlet tubing, tool kit28) Technology:- Luminescent Dissolved Oxygen (LDO)Remarks:-Additional01 No. Extrenal Power supply for 3100
2
After Cation Conductivity Meter1. Conductivity portable system Mounted on small aluminium panel with supporting stand and rechargeble bettery.2. Tranmitter in aluminium housing (IP 66) with 2 relays as limit switch or controller or timer, 1 alaram relay as summary alarm contact.1 input for portable free contact, including USB interface with 1 singal output for measurin value or for continouse control.3. Flow cell QV-Flow UP-Con 1000-SL made of stainless steel with flow adjustment valve and digital sample flow meter.4. Swam-Sensor UP-Com1000-S, two electrode conductvity sensor with slot-lock design anditergrated Pt1000 temperature pr be.Rechargeble battery for stand-alone operation of at least 24 hourse.Measuring range:- 0.055 to 1000 µs/cmAccuracy:- ±1% of measure valuePower supply:- 85-265 VAC : 50/60 HzStand - alone opening time:- >24 Hr.Samle Flow rate:- 5 to 20 I/hsample temparature:- up to 50ºCProcess connection inlet:-Swagelok 0.25% tube adapterProcess connection Outlet:-Flexible tube 8 x 6 minTotal weight:- 4.5 KgLoose cation Clum:-Duplex cation column:- One acting + One stanbayRemark:-Additional supply, 01 No. Conductivity Meter of ACC meter.
3
Flue Gas Analyzer(i) Flue gas analyzer with rechargeable battery with charger, transport case and calibration protocol, equipped With 02 sensor & pressure /flow measurement, mains unit 100-240V for mains operation or battery charging in instrument.(ii) Modular flue gas probe with 2nos. preliminary filter: 700mm immersion depth inclusive probe stop, thermocouple Ni (Cr)-Ni(Ti), T-max 1000 deg cent. & hose 2.2M with special 1.5 mtr probe extra for high temperature with hose pipe.(iii) A second measurement module must be fitted, three additional measurement module can be fitted inclusive of one point calibration with certificate.(iv) Relevant software(v) Essential accessories shall include spare particle filter t33x range(20Nos.), spare sintered filters (4pcs)(vi) Oxygen range (02):- 0-21%, Accuracy ±2% O2, Resolution -0.1%(vii)CO (H2 compensated) Measurement Module: 0- 10000 ppm, Resolution -1ppm, Accuracy ±20ppm <500 ppm, ±5% of FS>500 ppm.(viii) NO Measurement Resolution 1 ppm Module : 0-5000 ppm, Accuracy ±5ppm <100 ppm, ±5% of FS>100 ppm.(ix) SO2Measurement Module : 0-5000 ppm Resolution 1 ppm, Accuracy ±5ppm <100 ppm, ±5% of FS>100 ppm.(x) The instrument shall be capable to work under temp. range 137 ºC to 330 ºC & Pressure range -45 mmwc to -150 mmwc.