Power Boards / Undertakings / PSU Closing in 0 days TDR #43780118

Tender For Supply Installation And Commissioning Of Various Instruments For Chemical Laboratory To Analysis Of Various Parameter Of Water And Flue Gasses At Ctpp-O&M, Chhabra

Issued by Boards / Undertakings / PSU · chhabra, Rajasthan
Tender Value
17.84 Lakhs
Estimated cost
Bid Submission
11 Jul 2024
0 days left
EMD
35680
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
chhabra → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Supply Installation And Calibration Of Various Instruments For Chemical Laboratory To Analysis Of Various Parameter Of Water And Flue Gasses At Ctpp-Oandm, Chhabra , Dissolve Oxygen Meter 1) Accuracy: ± 0.8 Ppb Or ± 2 % 2) Application: Industrial 3) Battery Life: Rechargeable Battery, Lithium Ion, 10 Hours Of Continous Use 4) Certifications: Lvd Iec/En 61010-1, Emc Iec/En 61326-1 & Ecodesign Directive 5) Communication: Data Monitoring Per Rs232 Data/Configuration Transfer Per Usb Key 6) Communication Capabilities: Rs232 - Usb Key 7) Connections: 6 Mm (¼) 8) Data Storage: 5700 Measurements 9) Dimensions (H X W X D): 200 Mm X 170 Mm X 190 Mm 10) Display: Tft Colour 72 X 54 Mm 11) Includes: 3100 Instrument, External Power Supply, Us Power Plug, 3 M Inlet Tubing, Tool Kit 12) Lower Limit Of Detection (Lod): 0.6 Ppb 13) Material: Enclosure: Stainless Steel, Ip66 With Polycarbonate Sides 14) Operating Temperature Range: -5 - 45 °C 15) Parameter: Oxygen 16) Power Options: Us Power Cord 17) Range: 0 - 2000 Ppb 18) Response Time: < 15 S 19) Sample Interval: 5 - 60 S 20) Sample Pressure: 0 - 10 Bar 21) Sample Temperature: -5 - 45°C (41 - 113°F) 22) Tube Connection: 1/4 In 23) Units: Ppb, Ppm, Wt %, Mg/L, O2 %, Mbar And More 24) Wall Thickness: 1/4 In 25) Warranty: 12 Months 26) Weight: < 3.5 Kg 27) Whats Included: 3100 Instrument, External Power Supply, Us Power Plug, 3 M Inlet Tubing, Tool Kit 28) Technology:- Luminescent Dissolved Oxygen (Ldo) Remarks:-Additional01 No. Extrenal Power Supply For 3100 , After Cation Conductivity Meter 1. Conductivity Portable System Mounted On Small Aluminium Panel With Supporting Stand And Rechargeble Bettery. 2. Tranmitter In Aluminium Housing (Ip 66) With 2 Relays As Limit Switch Or Controller Or Timer, 1 Alaram Relay As Summary Alarm Contact.1 Input For Portable Free Contact, Including Usb Interface With 1 Singal Output For Measurin Value Or For Continouse Control. 3. Flow Cell Qv-Flow Up-Con 1000-Sl Made Of Stainless Steel With Flow Adjustment Valve And Digital Sample Flow Meter. 4. Swam-Sensor Up-Com1000-S, Two Electrode Conductvity Sensor With Slot-Lock Design And Itergrated Pt1000 Temperature Pr Be. Rechargeble Battery For Stand-Alone Operation Of At Least 24 Hourse. Measuring Range:- 0.055 To 1000 ?S/Cm Accuracy:- ±1% Of Measure Value Power Supply:- 85-265 Vac : 50/60 Hz Stand - Alone Opening Time:- >24 Hr. Samle Flow Rate:- 5 To 20 I/H Sample Temparature:- Up To 50ºc Process Connection Inlet:-Swagelok 0.25% Tube Adapter Process Connection Outlet:-Flexible Tube 8 X 6 Min Total Weight:- 4.5 Kg Loose Cation Clum:- Duplex Cation Column:- One Acting + One Stanbay Remark:-Additional Supply, 01 No. Conductivity Meter Of Acc Meter. , Flue Gas Analyzer (I) Flue Gas Analyzer With Rechargeable Battery With Charger, Transport Case And Calibration Protocol, Equipped With 02 Sensor & Pressure /Flow Measurement, Mains Unit 100-240V For Mains Operation Or Battery Charging In Instrument. (Ii) Modular Flue Gas Probe With 2Nos. Preliminary Filter: 700Mm Immersion Depth Inclusive Probe Stop, Thermocouple Ni (Cr)-Ni(Ti), T-Max 1000 Deg Cent. & Hose 2.2M With Special 1.5 Mtr Probe Extra For High Temperature With Hose Pipe. (Iii) A Second Measurement Module Must Be Fitted, Three Additional Measurement Module Can Be Fitted Inclusive Of One Point Calibration With Certificate. (Iv) Relevant Software (V) Essential Accessories Shall Include Spare Particle Filter T33x Range(20Nos.), Spare Sintered Filters (4Pcs) (Vi) Oxygen Range (02):- 0-21%, Accuracy ±2% O2, Resolution -0.1% (Vii)Co (H2 Compensated) Measurement Module: 0- 10000 Ppm, Resolution -1Ppm, Accuracy ±20Ppm <500 Ppm, ±5% Of Fs>500 Ppm. (Viii) No Measurement Resolution 1 Ppm Module : 0-5000 Ppm, Accuracy ±5Ppm <100 Ppm, ±5% Of Fs>100 Ppm. (Ix) So2measurement Module : 0-5000 Ppm Resolution 1 Ppm, Accuracy ±5Ppm <100 Ppm, ±5% Of Fs>100 Ppm. (X) The Instrument Shall Be Capable To Work Under Temp. Range 137 ºc To 330 ºc & Pressure Range -45 Mmwc To -150 Mmwc.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 04-Jul-2024 Date Extension-I Date 11-Jul-2024

BOQ

Name of Work: Supply Installation and Commissioning of various Instruments for Chemical laboratory to analysis of various parameter of water and Flue gasses at CTPP-O&M, Chhabra
Sl. No. Item Description
1Dissolve Oxygen Meter 1) Accuracy: ± 0.8 ppb or ± 2 %2) Application: Industrial3) Battery Life: Rechargeable battery, Lithium Ion, 10 hours of continous use4) Certifications: LVD IEC/EN 61010-1, EMC IEC/EN 61326-1 & Ecodesign Directive5) Communication: Data monitoring per RS232 Data/configuration transfer per USB key6) Communication Capabilities: RS232 - USB Key7) Connections: 6 mm (¼\")8) Data Storage: 5700 measurements9) Dimensions (H x W x D): 200 mm x 170 mm x 190 mm10) Display: TFT colour 72 x 54 mm11) Includes: 3100 instrument, external power supply, US power plug, 3 m inlet tubing, tool kit12) Lower Limit of Detection (LOD): 0.6 ppb13) Material: Enclosure: Stainless steel, IP66 with polycarbonate sides14) Operating temperature range: -5 - 45 °C15) Parameter: Oxygen16) Power Options: US Power Cord17) Range: 0 - 2000 ppb18) Response time: < 15 s19) Sample Interval: 5 - 60 s20) Sample Pressure: 0 - 10 bar21) Sample Temperature: -5 - 45°C (41 - 113°F)22) Tube Connection: 1/4 in23) Units: ppb, ppm, wt %, mg/L, O2 %, mbar and more24) Wall Thickness: 1/4 in25) Warranty: 12 months26) Weight: < 3.5 kg27) What\"s included: 3100 instrument, external power supply, US power plug, 3 m inlet tubing, tool kit28) Technology:- Luminescent Dissolved Oxygen (LDO)Remarks:-Additional01 No. Extrenal Power supply for 3100
2After Cation Conductivity Meter1. Conductivity portable system Mounted on small aluminium panel with supporting stand and rechargeble bettery.2. Tranmitter in aluminium housing (IP 66) with 2 relays as limit switch or controller or timer, 1 alaram relay as summary alarm contact.1 input for portable free contact, including USB interface with 1 singal output for measurin value or for continouse control.3. Flow cell QV-Flow UP-Con 1000-SL made of stainless steel with flow adjustment valve and digital sample flow meter.4. Swam-Sensor UP-Com1000-S, two electrode conductvity sensor with slot-lock design anditergrated Pt1000 temperature pr be.Rechargeble battery for stand-alone operation of at least 24 hourse.Measuring range:- 0.055 to 1000 µs/cmAccuracy:- ±1% of measure valuePower supply:- 85-265 VAC : 50/60 HzStand - alone opening time:- >24 Hr.Samle Flow rate:- 5 to 20 I/hsample temparature:- up to 50ºCProcess connection inlet:-Swagelok 0.25% tube adapterProcess connection Outlet:-Flexible tube 8 x 6 minTotal weight:- 4.5 KgLoose cation Clum:-Duplex cation column:- One acting + One stanbayRemark:-Additional supply, 01 No. Conductivity Meter of ACC meter.
3Flue Gas Analyzer(i) Flue gas analyzer with rechargeable battery with charger, transport case and calibration protocol, equipped With 02 sensor & pressure /flow measurement, mains unit 100-240V for mains operation or battery charging in instrument.(ii) Modular flue gas probe with 2nos. preliminary filter: 700mm immersion depth inclusive probe stop, thermocouple Ni (Cr)-Ni(Ti), T-max 1000 deg cent. & hose 2.2M with special 1.5 mtr probe extra for high temperature with hose pipe.(iii) A second measurement module must be fitted, three additional measurement module can be fitted inclusive of one point calibration with certificate.(iv) Relevant software(v) Essential accessories shall include spare particle filter t33x range(20Nos.), spare sintered filters (4pcs)(vi) Oxygen range (02):- 0-21%, Accuracy ±2% O2, Resolution -0.1%(vii)CO (H2 compensated) Measurement Module: 0- 10000 ppm, Resolution -1ppm, Accuracy ±20ppm <500 ppm, ±5% of FS>500 ppm.(viii) NO Measurement Resolution 1 ppm Module : 0-5000 ppm, Accuracy ±5ppm <100 ppm, ±5% of FS>100 ppm.(ix) SO2Measurement Module : 0-5000 ppm Resolution 1 ppm, Accuracy ±5ppm <100 ppm, ±5% of FS>100 ppm.(x) The instrument shall be capable to work under temp. range 137 ºC to 330 ºC & Pressure range -45 mmwc to -150 mmwc.

AI Tender Summary

OUR REF NO 43780118
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 17.84 Lakhs
LAST DATE 11-07-2024
Authority
Authority Name Rajasthan Rajya Vidhyut Utpadan Nigam Limited
Work Description Supply Installation And Calibration Of Various Instruments For Chemical Laboratory To Analysis Of Various Parameter Of Water And Flue Gasses At Ctpp-Oandm, Chhabra , Dissolve Oxygen Meter 1) Accuracy: ± 0.8 Ppb Or ± 2 % 2) Application: Industrial 3) Battery Life: Rechargeable Battery, Lithium Ion, 10 Hours Of Continous Use 4) Certifications: Lvd Iec/En 61010-1, Emc Iec/En 61326-1 & Ecodesign Directive 5) Communication: Data Monitoring Per Rs232 Data/Configuration Transfer Per Usb Key 6) Communication Capabilities: Rs232 - Usb Key 7) Connections: 6 Mm (¼) 8) Data Storage: 5700 Measurements 9) Dimensions (H X W X D): 200 Mm X 170 Mm X 190 Mm 10) Display: Tft Colour 72 X 54 Mm 11) Includes: 3100 Instrument, External Power Supply, Us Power Plug, 3 M Inlet Tubing, Tool Kit 12) Lower Limit Of Detection (Lod): 0.6 Ppb 13) Material: Enclosure: Stainless Steel, Ip66 With Polycarbonate Sides 14) Operating Temperature Range: -5 - 45 °C 15) Parameter: Oxygen 16) Power Options: Us Power Cord 17) Range: 0 - 2000 Ppb 18) Response Time: < 15 S 19) Sample Interval: 5 - 60 S 20) Sample Pressure: 0 - 10 Bar 21) Sample Temperature: -5 - 45°C (41 - 113°F) 22) Tube Connection: 1/4 In 23) Units: Ppb, Ppm, Wt %, Mg/L, O2 %, Mbar And More 24) Wall Thickness: 1/4 In 25) Warranty: 12 Months 26) Weight: < 3.5 Kg 27) Whats Included: 3100 Instrument, External Power Supply, Us Power Plug, 3 M Inlet Tubing, Tool Kit 28) Technology:- Luminescent Dissolved Oxygen (Ldo) Remarks:-Additional01 No. Extrenal Power Supply For 3100 , After Cation Conductivity Meter 1. Conductivity Portable System Mounted On Small Aluminium Panel With Supporting Stand And Rechargeble Bettery. 2. Tranmitter In Aluminium Housing (Ip 66) With 2 Relays As Limit Switch Or Controller Or Timer, 1 Alaram Relay As Summary Alarm Contact.1 Input For Portable Free Contact, Including Usb Interface With 1 Singal Output For Measurin Value Or For Continouse Control. 3. Flow Cell Qv-Flow Up-Con 1000-Sl Made Of Stainless Steel With Flow Adjustment Valve And Digital Sample Flow Meter. 4. Swam-Sensor Up-Com1000-S, Two Electrode Conductvity Sensor With Slot-Lock Design And Itergrated Pt1000 Temperature Pr Be. Rechargeble Battery For Stand-Alone Operation Of At Least 24 Hourse. Measuring Range:- 0.055 To 1000 ?S/Cm Accuracy:- ±1% Of Measure Value Power Supply:- 85-265 Vac : 50/60 Hz Stand - Alone Opening Time:- >24 Hr. Samle Flow Rate:- 5 To 20 I/H Sample Temparature:- Up To 50ºc Process Connection Inlet:-Swagelok 0.25% Tube Adapter Process Connection Outlet:-Flexible Tube 8 X 6 Min Total Weight:- 4.5 Kg Loose Cation Clum:- Duplex Cation Column:- One Acting + One Stanbay Remark:-Additional Supply, 01 No. Conductivity Meter Of Acc Meter. , Flue Gas Analyzer (I) Flue Gas Analyzer With Rechargeable Battery With Charger, Transport Case And Calibration Protocol, Equipped With 02 Sensor & Pressure /Flow Measurement, Mains Unit 100-240V For Mains Operation Or Battery Charging In Instrument. (Ii) Modular Flue Gas Probe With 2Nos. Preliminary Filter: 700Mm Immersion Depth Inclusive Probe Stop, Thermocouple Ni (Cr)-Ni(Ti), T-Max 1000 Deg Cent. & Hose 2.2M With Special 1.5 Mtr Probe Extra For High Temperature With Hose Pipe. (Iii) A Second Measurement Module Must Be Fitted, Three Additional Measurement Module Can Be Fitted Inclusive Of One Point Calibration With Certificate. (Iv) Relevant Software (V) Essential Accessories Shall Include Spare Particle Filter T33x Range(20Nos.), Spare Sintered Filters (4Pcs) (Vi) Oxygen Range (02):- 0-21%, Accuracy ±2% O2, Resolution -0.1% (Vii)Co (H2 Compensated) Measurement Module: 0- 10000 Ppm, Resolution -1Ppm, Accuracy ±20Ppm <500 Ppm, ±5% Of Fs>500 Ppm. (Viii) No Measurement Resolution 1 Ppm Module : 0-5000 Ppm, Accuracy ±5Ppm <100 Ppm, ±5% Of Fs>100 Ppm. (Ix) So2measurement Module : 0-5000 Ppm Resolution 1 Ppm, Accuracy ±5Ppm <100 Ppm, ±5% Of Fs>100 Ppm. (X) The Instrument Shall Be Capable To Work Under Temp. Range 137 ºc To 330 ºc & Pressure Range -45 Mmwc To -150 Mmwc.
Basic Detail
Tender No 2004/24-25
Bidding Type Tender
Location
City chhabra
State Rajasthan
Key Dates
Publish Date 04 Jul 2024
Submission Date 11 Jul 2024
Open Date 12 Jul 2024
Finance
Tender Value 17.84 Lakhs
Tender Fee 590
EMD 35680
Exemption Available
Document List
f18bb562-7845-4b54-8255-b75f65678ea2.html
BOQ_706452.xls
Tendernotice_1.pdf
TN2004.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 04, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 11, 2024
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 11, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 12, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

f18bb562-7845-4b54-8255-b75f65678ea2.html

xls

BOQ_706452.xls

pdf

Tendernotice_1.pdf

pdf

TN2004.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders