Tender for electrical works of semen bank at mattupatty farm at kld board, mattupatty unitu, idukki (district), kerala -1 1.10.1 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed medium class pvc conduit,with modular switch modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frlspvc insulated copper conductor single core cable etc as required.group a 2 1.10.2 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed medium dlass pvc conduit,with modular switch modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frlspvc insulated copperconductor singlé core cable etc as required.group b 3 1.10.3 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvcinsulated ccpper conductor single core cable in surface / recessed medium class pvc conduit,with modular switch modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frlspvc insulated copper conductor single core cable etc as required.group c 4 1.17.3 supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel/ pvc conduit as required.3 x 1.5 sq.mm 5 1.17.12 supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel/ pvc conduit as required.3 x 2.5 sq. mm 6 1.21.1 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 7 1.21.2 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 8 1.24.3 supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.15/16 amp switch 9 1.24.5 supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding moc!ular plate etc. as required.6 pin 15/16 amp socket outlet 10 1.25 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 11 1.27.1 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 module (75mmx75mm) 12 1.27.2 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc as required.3 module (100mmx75mm) 13 1.31 supplying and fixing suitable size gi box with modular plate and cover in front on surface or inrecess including providing and fixing 3 pin 5/6 amps modu1ar socket outlet and 5/6 ampsmodujar switch connection etc. as required. (for light plugs to be used in non residentialbuildings). 14 1.33 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required. 15 2.3.3 supplying and fixing following way, single pole. and neutral, sheet steel, mcb distribution board, 240 v on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc. as required. (but without mcbirccb/lsolator12way, double door 16 2.10.1 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.single pole 17 2.11 supplying and fixing single pole blanking plate in the existing mcb db complete etc. as required. 18 2.12.1 supplying and fixing following rating, double pole, 240 volts, isolator in the existing mcb db complete with connéctions, testing and commissioning etc. as required.40 amps 19 2.14.2 supplying and fixing following rating , double pole, (single phase and neutral), 240 v residual curent circuiti breaker (rccb) having a sensitivity current 30 ma in the existing mcb db eomplete with connections, testing and commissioning etc. as required . 40 amps. 20 90.4.1 supply and installation of suitable size ms rod type fan clamp in the rcc slab as per is 732 as required. 21 90.12.7.40 supply, laying and clamping of 1 no. pvc insulated and pvc sheathed armoured aluminium power cable, 1.1 kv grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the, damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 22 90.16.1.5 supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 swg) 23 od156064/2023_2024 supply and fixing of 400mm wall fan ,giving proper connection as required. make-havells or equivalent. 24 od155856/2023_2024 supply installation testing and commissioning of 35 w led pressure die cast aluminium housing led top light fitting (ip66 protection) with lamp (govt. approved and reputed brabds like wipro or philips) on 40 mm or nearest suitable size b class gi pipe 1m long cut and weld,bend to shape fixed on wall using flat iron clamps giving connection with required painting the gi pipe and clamps with all necessary items making good the surface as required 25 od155857/2023_2024 supply of 20w led tube light fitting have 2000lumen with duly wired up for use on 230 v ac. the fittings shall be directly on ceiling/ wall, including all accessories etc. as required. make -philips or equivalent