Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 03-07-2024 | GENERAL SUMMARY | Other | 12-07-2024 |
| 2 | 03-07-2024 | SCHEDULE OF CREDIT | Other | 12-07-2024 |
| 3 | 03-07-2024 | BOQ CORRIGENDUM | BOQ | 12-07-2024 |
| 4 | 03-07-2024 | DATE CORRIGENDUM | Date | 12-07-2024 |
| Sl. No. | Item Description |
| 1 | B/R WORKS |
| 2 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and disposing off complete all as specified and as directed |
| 3 | Dismantling stone slabs of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar and disposing off complete all as specified and as directed |
| 4 | Dismantling of plain or corrugated steel sheeting, any gauge or any thickness in roof covering /wall cladding complete all as specified and as directed |
| 5 | Dismantling mild steel work or wraught iron of any description and in any position complete all as specified and as directed |
| 6 | Demolition of reed, lathing, single or double including battens and plaster or chiken wire lathing complete all as specified and as directed |
| 7 | Dismantling of timber scantling 40sqcm and over in section, in any position in unframed works complete all as specified and as directed |
| 8 | Dismantling of timber fillets rails, posts, rafters, purlins, etc. under 40sqcm in section, in any position in unframed works complete all as specified and as directed |
| 9 | Dismantling wall and ceilingboards (fibre, pulb, insulation, etc.) or insulation boards slabs/blankets of any thickness including cover fillets complete all as specified and as directed |
| 10 | Taking down cement or cement lime plaster,any description on brick or stone walls, etc. including raking out joints, hacking for keys, scubbing down with water, etc. including all necessary scaffolding as required and rubbishing off the premises, etc. complete all as specified and as directed |
| 11 | Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles and disposing off complete all as specified and as directed |
| 12 | Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and removal of debris complete all as specified and as directed |
| 13 | Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed |
| 14 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for and removal of debris complete all as specified and as directed |
| 15 | Taking down chowkats or frames not exceeding 1.5sqm each with shutters (without taking off shutters from the frame), disposing off and making good the disturbed areas, portions and surfaces |
| 16 | Taking down chowkats or frames exceeding 1.5sqm but not exceeding 4.0sqm each with shutters (without taking off shutters from the frame), disposing off and making good the disturbed areas, portions and surfaces |
| 17 | Dismantling asbestos cement / PVC rain water pipes, etc. 75/100mm bore, of any type including clamps, fitting, etc. complete all as specified and as directed |
| 18 | Cutting chases, pinning in brick walls and making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10cm in girth complete all as specified and as directed |
| 19 | S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar works conforming to Fe-290 grade E-165 complete all as specified and as directed |
| 20 | S&F of mild steel rolled sections as in main and cross beams, hip and jack rafters, purlins, brackets for fixing of eaves board, posts, etc. where connected to common rafters and other miscellaneous brackets fixed with angle cleats or other connecting plates conforming to Fe-290, grade E-165 complete all as specified and as directed |
| 21 | M&L for mild steel TMT bars 10mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed |
| 22 | M&L for mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed |
| 23 | M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders securing with clips complete all as specified and as directed |
| 24 | M&L for formwork to sides and soffits of floor or roof beam, beam haunching, girder, lintels, cantilever, shelves including supports, etc. for rough finished flat surfaces of concrete complete all as specified and as directed |
| 25 | M&L for formwork to soffits of suspended slabs, such as roof slab, floor slab, landings and similar works not exceeding 200mm thick for rough finished flat surfaces of concrete complete all as specified and as directed |
| 26 | M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 200mm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 50mm but n exceeding 100mm wide complete all as specified and as directed |
| 27 | M&L for brickwork with sub-class \"B\" bricks, straight or curved on plan to any radius built in CM (1:6) complete all as specified and as directed |
| 28 | M&L for brickwork with sub-class \"B\" bricks, straight or curved on plan to any radius as in half brick thick walls built in CM (1:4) complete all as specified and as directed |
| 29 | M&L for 100mm thick plain cement concrete 1:3:6 (type C-2) using 40mm graded stone aggregate as in floors, sub-bases, pavings, etc. surface finished fair and even complete all as specified and as directed |
| 30 | M&L for plain cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregates) as in surface channels, drains, etc. complete all as specified and as directed |
| 31 | M&L for 75mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregates) as in floors, plinth protection, pavings, etc. surface finished even and fair, laid in alternate bays/panels and joints filled with bituminous mix of 1 part bitumen and 3 part of sand complete all as specified and as directed |
| 32 | M&L for cement concrete 1:3:6 type C-0 (using 12.5mm graded stone aggregates) as in back filling of steel frame and holdfasts, etc. including necessary formwork complete all as specified and as directed |
| 33 | M&L RCC (1:1.5:3) type A-1, nominal mix using 20mm graded stone aggegates as in beams, cantilevers, lintels, etc. over 1.5m in span complete all as specified and as directed |
| 34 | M&L RCC M 25 design mix as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed |
| 35 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc. complete all as specified and as directedNote: Inner girth shall only be measured |
| 36 | Add or deduct for each 25mm girth or part thereof over or under 30cm (for adjustment ingirth against serial item No. 35 hereinabove) |
| 37 | M&L rendering 15mm thick, in cement mortar (1:4) on walls / concretesurfaces, etc. in two layers (10+5mm) finishing layer mixed with integral water proofing compound @3% by weight of cement, finished even and smooth without using extra cement complete all as specified and as directedNote: WPC will be measured and paid separately under respective item herein |
| 38 | M&L rendering 10mm thick, in cement mortar (1:6) on walls / concretesurfaces, etc. finished even and fair without using extra cement complete all as specified and as directed |
| 39 | Supply only integral water proofing compound all as specified |
| 40 | S&F pressed steel frames made of 1.25mm thick MS sheet of profile 105x60mm for door and window frames with one or more rebates including hinges (100/50mm stainless steel), lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of aldrop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs, etc. complete all as specified and as directed |
| 41 | S&F pressed steel frames made of 1.25mm thick MS sheet of profile 125x60mm for door and window frames with one or more rebates including hinges (100/50mm stainless steel), lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of aldrop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs, etc. complete all as specified and as directed |
| 42 | S&F steel ventilator with top hung shutter including hinges, steel peg stay, lugs as in hold fast including suitable locking arrangements complete all as specified and as directed |
| 43 | S&F steel windows with side hung shutters including box type hinges with steel handles, 100mm long peg stay complete with glazing bars, dovetailed or welded, including suitable locking arrangements complete all as specified and as directed |
| 44 | S&F steel windows with side hung shutters including box type hinges with steel handles, 100mm long peg stay complete without glazing bars, dovetailed or welded, including suitable locking arrangements complete all as specified and as directed |
| 45 | S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, smooth finish with lipping of teak wood on edges complete all as specified and as directed |
| 46 | S&F 2nd class hard wood 35mm thick plain, framed, paneled shutters (any number of panels), with panels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers, supplied and fitted to chowkats complete all as specified and as directed |
| 47 | S&F 35mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge, etc and divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, sizes of members of shutters as specified in clause 8.20 9(b) of SSR Part-I, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., supplied and fitted to chowkats complete all as specified and as directed |
| 48 | M&L for 2nd class hard wood timber scantling wrought, 40sqcm and above in section, timber framed & fixed complete all as specified and as directed |
| 49 | M&L for 2nd class hard wood timber scantling clean sawn, 40sqcm and above in section, timber framed & fixed complete all as specified and as directed |
| 50 | S&F 2nd class hard wood 50mm thick boarding, wrought, fixed with nails in any position (except flooring and skirting) with butt joints complete all as specified and as directed |
| 51 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed |
| 52 | S&F GI wire netting 0.71mm dia and 12mm mesh lathing to wood or metal studding joints, etc. in walls, ceiling stanchion, beams, etc. including all laps cutting and wastes complete all as specified and as directed |
| 53 | S&F 3mm thick sheet glass ordinary quality and glazing with oil putting square not exceeding 0.5sqm in each pane including hacking out old glass complete all as specified and as directed |
| 54 | S&F 200mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and as directed |
| 55 | S&F 150mm extruded aluminum alloy handles, cast type, anodized complete all as specified and as directed |
| 56 | S&F 300mm aluminium anodised sliding door bolt with hasp and staple, bolt type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed |
| 57 | S&F in repairs 25mm dia fancy type MS chromium plated (tint as approved) MS curtain / drapery rods, etc. of rod wall thickness 1mm (min), including pair of brackets, holders with funnel at ends complete all as specified and as directed |
| 58 | M&L for preparation of masonry / concrete wall surfaces and applying1mm thick wall care putty rubbed with sand paper for making surface smooth and even including all necessary staging, scaffolding, etc. as required to work at heights, etc. complete all as specified and as directed |
| 59 | M&L for preparation of new masonry / concrete ceiling surfaces and applying three coats of white wash including all necessary staging, etc. as required complete all as specified and as directed |
| 60 | M&L for complete removal and preparation of old decorated surfaces of walls by brooming down or steel wire brushing, scrapping down smoke shoots, moulds, moss and efforescent salts, trading oil, greasy spots, etc.and applying two coats of white wash including all necessary staging, etc. as required complete all as specified and as directed |
| 61 | M&L for preparation of new masonry / concrete wall surfaces and applying two coats of oil emulsion distemper over a coat of wall primer including all necessary staging, scaffolding, etc. as required to work at heights, etc. complete all as specified and as directed |
| 62 | M&L for preparation of new plastered surfaces and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali & fungus resistant, dirt resistant, exterior paint (of approved tint, company depot tinted) with silicon additives @1.43litre/10sqm over a priming coat of exterior primer applied @0.90litre/10sqm complete all as specified and as directed |
| 63 | M&L for complete removal and preparation of old decorated surfaces of walls by brooming down or steel wire brushing, scrapping down smoke shoots, moulds, moss and efforescent salts, trading oil, greasy spots, etc. and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistant, dirt resistant, exterior paint of approved shade (company depot tinted) with silicon additives @1.43litre/10sqm over and including a priming coat of exterior primer applied @0.90 litre/10sqm including all necessary staging, scaffolding, etc.required complete all as specified as as directed |
| 64 | M&L for preparing of new steel / metal surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed |
| 65 | M&L for preparing of old steel / metal surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed |
| 66 | M&L for preparing of new wood / wood based surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, tint as approved complete all as specified and as directed |
| 67 | M&L for preparing of old wood / wood based surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint, tint as approved complete all as specified and as directed |
| 68 | M&L for preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with creosote oil complete all as specified and as directed |
| 69 | M&L for non-skid ceramic tiles, coloured, area of tile exceeding 0.11sqm but not exceeding 0.18sqm each, 7 to 8mm thick of superior quality as in floors, etc. laid over 15mm thick screed bed in CM (1:6) (rate shall be included) set and jointed in neat cement slurry @3.00kg of cement per sqm and pointed in white cement mixed with colouring pigment to match shade of tiles complete all as specified and as directed |
| 70 | M&L for glazed ceramic tiles, coloured, of size 450x350mm, 6 to 7mm thick, of superior quality as in vertical surfaces, skirting, dado, etc. laid over 10mm thick backing coat in CM (1:4) (rate shall be included) pointed in white cement mixed with colouring pigment to match shade of tiles complete all as specified and as directed |
| 71 | M&L for vitrified tiles, coloured, 10mm thick, joint free, edge cut, area of each tile exceeding 0.18sqm but not exceeding 0.36sqm, of superior quality on floors, etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the colour of tiles, laid over and including 15mm thick screed bed in CM (1:6) (rate shall be included) complete all as specified and as directed |
| 72 | M&L for vitrified tiles, coloured, 10mm thick, joint free, edge cut, area of each tile exceeding 0.18sqm but not exceeding 0.36sqm, of superior quality onskirting, dado, etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the colour of tiles, laid over and including 10mm thick screed bed in CM (1:4) (rate shall be included) complete all as specified and as directed |
| 73 | M&L machine cut and machine polished kota stone slab 20 to 25mm thick as in floors, in single pieces, set and jointed in neat cement slurry @4kg/sqm and pointed with cement and pigments to match the shade of slab including rubbing and polishing etc. complete all as specified and as directed |
| 74 | M&L for 20mm thick granite stone slab, of any type, table rounded, rubbed and polished, in cills, cooking platforms, partitions and the like set in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of slab complete all as specified and as directed |
| 75 | M&L for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system) of grid size 600x600mm with main runner 38x24mm and wall angle 24x24mm using 4mm thick high pressure non-asbestos fiber cement decorative board (E-Board Classic) in grid of GI system duly suspended from 4mm dia GI bar hanger fixed with steel dash fasteners or iron purlin from roof with adjustment clips, providing positions for light fixtures, air conditioning, diffuser and ducts, sprinkler, smoke detectors, etc., cnforming to IS 14862, the main runners duly secured to structural soffits by hanger @1220mm c/c (maximum) with the last hanger at the end of each main runner not interlocked between main runners @610mm c/c so as to form 600x600mm grid complete all as specified and as directed |
| 76 | S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering, cladding to walls, etc. fixed with self tapping screws complete all as specified and as directed |
| 77 | S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering, cladding to walls, etc. fixed with self tapping screws complete all as specified and as directed |
| 78 | S&F steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections including taking up/down old unserviceable tubing from any location/position and disposing off complete all as specified and as directed of the following bores: |
| 79 | 15mm bore |
| 80 | 20mm bore |
| 81 | S&F in repairs gun metal globe or gate valve, 20mm dia, with iron wheel head, screwed both ends for iron pipe and fixed including necessary cutting into existing pipe, threading, inserting new piece of GI pipe of existing size, breaking/cutting into cement concrete, masonry, etc. and making good the disturbed surfaces complete all as specified and as directed |
| 82 | S&F in repairs wash hand basin, vitreous China, white, oval counter top type, of size 565x465x185mm including waste coupling and including PVC connection 60cm key with brass union complete all as specified and as directed |
| 83 | S&F 10litres capacity PVC flushing tank, white / coloured, syphonic action type, low level, valveless, with PVC inlet ball valve, PVC flush pipe, float and suitable sized brackets including cutting of floor / wall and making good to the disturbed surfaces in CM 1:3 with finishes to match with the existing and taking down of old PVC flush tank and disposing off complete all as specified and as directed |
| 84 | S&F in repairs kitchen sink, overall size 495x420mm and bowl size 410x330x160mm, made of stainless steel 1mm thick, with plugs, washer and waste pipe including duly fixing to cantilever brackets and connection union to pipe, filling joints with wall in white cement complete all as specified and as directed |
| 85 | S&F in repairs 15mm bib taps, chromium plated, cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed |
| 86 | S&F in repairs 15mm dia bib taps, fancy type, PTMT any colour, high pressure (minimum weight 90gms) screwed down, screwed for iron pipe complete all as specified and as directed |
| 87 | S&F in repairs 15mm dia pillar taps, fancy type, cast copper alloy, with capstain heads, chromium plated, screwed down, high pressure, with or without lettered \"HOT\"/\"COLD\", with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed |
| 88 | S&F in repairs 15mm dia pillar taps, fancy type, PTMT any colour, high pressure (minimum weight 125gms) screwed down, screwed for iron pipe complete all as specified and as directed |
| 89 | S&F in repairs 15mm dia stop cocks / angle valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions or for brass ferrule complete all as specified and as directed |
| 90 | S&F in repairs 15mm dia stop cocks / angle valves, PTMT any colour, high pressure (minimum weight 90gms) screwed down, screwed for iron pipe complete all as specified and as directed |
| 91 | S&F in repairs chromium plated mild steel soap dish of approved design, any type, fixed to plugs with chromium plated brass screws complete all as specified and as directed |
| 92 | S&F in repairs 125mm dia CP brass shower rose with swivel joints, any colour including shower arm 15mm dia, 195mm long with bend of 45o with flange of CP brass complete all as specified and as directed |
| 93 | S&F in repairs swivel mirror, round in shape, 450mm dia of selected quality glass and approved design, fixed to wooden plugs with chromium plated brass screws and cup washers / hinges, etc. complete all as specified and as directed |
| 94 | S&F in repairs 600x450mm full sized bevelled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed |
| 95 | S&F in repairs 15mm PVC connections, 450mm long with brass couplings, PTMT nuts, etc. complete all as specified and as directed |
| 96 | S&F 15mm PVC connections, 450mm long with brass couplings, PTMT nuts, etc. complete all as specified and as directed |
| 97 | S&F 32mm dia PVC waste pipe, with coupling, 900mm long, PTMT, half or full threaded complete all as specified and as directed |
| 98 | S&F in repairs towel rail, 20mm dia, brass chromium plated, 600mm long with fancy type with brass chromium plated brackets on both sides and fixed with steel screws and wooden/rawl plugs complete all as specified and as directed |
| 99 | S&F PVC (SWR) pipes, 75mm bore, single socketed in any length with rubber ring joints fixed on walls with suitable clamps, etc. complete all as specified and as directed |
| 100 | S&F in repairs 75mm bore PVC (SWR) bend of any radius with oval access door complete all as specified and as directed |
| 101 | E/M WORKS |
| 102 | Taking down copper / aluminium point wiring (light, fan, socket or power) including fixture and fittings viz. switches, ceiling roses, light fittings, pendants, regulators, sockets, etc. and disposing off complete all as specified and as directed |
| 103 | M&L for point wiring with 1.5sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade, IS-694 marked, with multi-stranded copper conductor, drawn through and including non-metallic heavy duty PVC casing capping not less than 20mm wide and accessories flush on walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly for one exhaust fan point complete all as specified and as directed for the following: |
| 104 | One light point controlled by one 5A one way switch |
| 105 | One ceiling fan / exhaust fan point controlled by one 5A one way switch |
| 106 | One switch socket outlet 3 pin 5A controlled by one switch on independent board |
| 107 | One switch socket outlet 3 pin 5A controlled by one switch on same board |
| 108 | M&L for point wiring with 2.5sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade, IS-694 marked, with multi-stranded copper conductor, drawn through and including non-metallic heavy duty PVC casing caping not less than 20mm wide and accessories flush on walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly for 3 pin 15A switch socket independent outlet complete all as specified and as directed |
| 109 | M&L for point wiring with 4sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade, IS-694 marked, with multi-stranded copper conductor, drawn through and including non-metallic heavy duty PVC conduit not less than 20mm dia and accessories flush on walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly for AC / equipment controlled by one SP/SPN MCB independent, wiring from DB to swicth socket running independently with 3 wires for each point without tapping complete all as specified and as directed |
| 110 | S&F ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals complete all as specified and as directed |
| 111 | S&F switch piano flush button type, single pole, ISI marked, one way 5A, 240V complete all as specified and as directed |
| 112 | S&F switch piano flush button type, single pole, ISI marked, one way 15A, 240V complete all as specified and as directed |
| 113 | S&F socket outlet, 2 in 1, 3 pin, 5A, ISI marked, flush type, 230V complete all as specified and as directed |
| 114 | S&F socket outlet, 2 in 1, 3 pin, 5 & 15A, ISI marked, flush type, 230V complete all as specified and as directed |
| 115 | S&F PVC / polycarbonate lamp holder, insulated body, bracket holder / angle holder with back plate 240V complete all as specified and as directed |
| 116 | S&F electronic fan regulator, stepped socket type (5 steps), 100W, 50Hz, 230V, ISI marked duly connected up complete all as specified and as directed |
| 117 | S&F in repairs steel water tubing, 32mm bore, light grade, galvanised, in any length, ISI marked conforming to IS -1239 and fixed to walls as in service brackets for mounting of fittings, cut to required length complete all as specified and as directed |
| 118 | S&F wall mounted, compact industrial batten type LED tube light fitting T-8 and connecting with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed |
| 119 | S&F wall mounted, compact LED tube rod with batten 20W and connecting with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed |
| 120 | S&F building security light, LEDluminaire 25W IP-66 protection class, with 25W LED lamp, driver, etc. with all accessories including taking down and disposing off old fitting complete all as specified and as directed |
| 121 | S&F12W LED bulb/lamp to existing holder including taking down and disposing off old bulb complete all as specified and as directed |
| 122 | S&F 600x600mm LED type down lighter 36W with drivers connecting accessories and provision of fixing arrangements in false ceiling and connecting up including taking down and disposing off old fitting complete all as specified and as directed |
| 123 | S&F BLDC ceiling fan 1200mm sweep, 230V, minimum air delivery 210CFM with service value 6.00 BEE 5 star rated, with blades, down rods and accessories and connecting up including disconnecting, taking down of old unserviceable fan and depositing to MES storeyard including all loading, unloading, carting, etc. complete all as specified and as directed |
| 124 | S&F heavy duty, steel body with steel blades, legs, ISI marked energy efficient, 230V, 50Hz, 1200RPM, exhaust fan, 380mm sweep with louvers and connecting up including provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including grouting the nuts and bolts and making good the disturbed areas and surfaces including taking down old unserviceable fans of any capacity and depositing in MES store yard including all loading, unloading, carting, etc. complete all as specified and as directed |
| 125 | S&F electric water heaters (geysers), stainless steel body, 25litres capacity, storage type, vertical mounting, with glass lined inner tank, energy efficient 5 star rated of approved design and colour, including 2kW heating element, all necessary clamps, grouting duly with holding bolts & nuts and all necessary connections at locations including taking down old unserviceable geysers of any capacity after disconnecting electric & water connections and depositing in MES store yard including all loading, unloading, carting, etc. complete all as specified and as directed |
| 126 | M&L for taking down carefully ceiling fan of any type from existing location and cleaning entirely with suitable cleansers, servicing, spray painting with synthetic enamel paint (of approved tint) including filling of cavities with filler, oiling moving parts, writing MES No. in Roman block letters & figures (of approved size) and refixing in existing / new location with provn of ‘S’ type fan hook including connecting electrically with new cable complete all as specified and as directed |
| 127 | M&L for taking down carefully metal exhaust fan of any type 300mm sweep, from existing location and cleaning entirely with suitable cleansers, servicing, spray painting with synthetic enamel paint (of approved tint) including filling of cavities with filler, oiling moving parts, writing MES No. in Roman block letters & figures (of approved size) and refixing in existing / new location duly grouted including connecting electrically with new cable complete all as specified and as directed |
| 128 | M&L for taking down carefully wall mounted fan of any type 300mm sweep, from existing location and cleaning entirely with suitable cleansers, servicing, spray painting with synthetic enamel paint (of approved tint) including filling of cavities with filler, oiling moving parts, writing MES No. in Roman block letters & figures (of approved size) and refixing in existing / new location duly grouted including connecting electrically with new cable complete all as specified and as directed |
| 129 | S&F sheet metal enclosures for 8 way MCB DB, 240V, SP, double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces including taking down of old enclosure and disposing off complete all as specified and as directed |
| 130 | S&F sheet metal enclosures for 4 way MCB DB, 240V, SP, double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces including taking down of old enclosure and disposing off complete all as specified and as directed |
| 131 | S&F sheet metal enclosures for 4 way MCB DB, 240V, TPN, double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces including taking down of old enclosure and disposing off complete all as specified and as directed |
| 132 | S&F metal clad socket outlet with single pole enclosure with 5 pin and earth plug socket including 1No. MCB SPN 40A 10kA 240V and taking down and disposing off old/unserviceable socket complete all as specified and as directed |
| 133 | Taking down old unserviceable submain wiring of any type, any size, from any location or position and disposing off including making good the disturbed surfaces, etc. complete all as specified and as directed |
| 134 | M&L for submain wring using proper colour codingwith 2 runs of single core, PVC insulated,FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 6sqmm and 1 run of 6sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC casing capping 20mm wide, heavy duty, ISI marked concealed in wall/ceiling/roof, etc. with all required accessories complete all as specified and as directedNotes:(i) 2 runs of 6sqmm main cable, 1 run of earth conductors and 1 run of PVC casing/capping shall be measured as one length(ii) Separate casing shall be used for each sub-main wiring circuit irrespective of numbers of wire(iii) The minimum size of casing shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of casing as per requirement at site |
| 135 | S&F in repairs MCB SP, 240V, 5 to 32A, 10kA, 50Hz, C curve complete all as specified and as directed |
| 136 | S&F in repairs MCB SPN, 240V, 40 to 63A, 10kA, 50Hz, C curve complete all as specified and as directed |
| 137 | S&F in repairs MCB TPN, 4 pole, 240V, 63A, 10kA, 50Hz, B curve complete all as specified and as directed |
| 138 | M&L for earthing using GI earthing wire with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth lead wire 4mm dia extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 15mm light grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications, taking down and disposing off old earthing complete all as specified and as directed |
| 139 | Notes for serial item No. 138: (i) The cost of GI earth continuity wire / strip with GI pipe 20mm medium grade upto 7.5m is deemed to be included(ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item(iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge |