Public Administrative Department Local Bodies Closing in 0 days TDR #43747981

Tender For Upgration Of Gp Office Building First Floor(15Th F.C) Activity Id-89394816

Issued by Local Bodies · paharpur, West Bengal
Tender Value
4.98 Lakhs
Estimated cost
Bid Submission
22 Jun 2024
0 days left
EMD
3995
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
paharpur → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

UPGRATION OF GP OFFICE BUILDING FIRST FLOOR(15th F.C) Activity ID-89394816

BOQ

Name of Work: UPGRATION OF GP OFFICE BUILDING FIRST FLOOR(15th F.C) Activity ID-89394816 NIT NO:-WB/JAL/SADAR/P.G.P/01/24-25
Sl. No. Item Description
1Description of work/ supply materials
2Dismantlingall types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubish as directed within a lead of 75m
3Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75m. Including stacking of steel bars.
4. 125 mm. thick brick work with 1st class bricks in cement morter (4:1) in1st floor.
5Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes
6Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(f) 25 mm to 30 mm shuttering with staging in foundation , in 1st floor
7Reinforcement for reinforced concrete work in all sorts of structuresincluding distribution bars, stirrups, binders etc initial straightening andremoval of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 mII. JSW/ISPL/SHYAM
8Plaster (to wall, floor, ceiling etc.) with sand and cement mortarincluding rounding off or chamfering corners as directed andraking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excludingcost of chipping over concrete surface](ii) With 1:4 cement mortara) 15 mm thick plaster in 1st floor
9Page No.66, Item No.36(I) a) Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxygrout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer\"s specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr]e) I(I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment.(A) Deep Colour & White In 1st Floor
10Providing and fixing of false ceiling with powder coated exposed G.I. gridsuspension system (E-Grid U-1520 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long andWall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placedperpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 15mm thick OW Acoustic Board (Mineral Fiber Acoustic Ceiling Tiles) of approved patern and size 595mm X 595mm with NRC value > 0.65 should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge. In ground floor.a) Acoustic False Ceiling (with 15mm thick OW Acoustic Board and E-Grid U-1520
11Supplying profiles of required section made of Aluminium AlloyExtrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). (A) In 10-12 Micron thickness Annodizing film I) Natural white b) 3- track sliding window i) Bottom frame
12Supplying profiles of required section made of Aluminium AlloyExtrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). (A) In 10-12 Micron thickness Annodizing film I) Natural white b) 3- track sliding window ii) Top and side frame
13Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units:-(A) Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDMgasketing in between window frame and masonry work (walls, column, beam.lintels etc.) as well as between glass and shutter frame for fixing glass and Polysulphide sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass as per drawing, specification and direction of EIC. The rate includes the hire charge of all tools and plants, including all incidental charges, adhesive, joineries such as screw, cleat angle etc. but excluding the cost of extruded aluminium sections, glass, neoprene / EPDM gasket, locking arrangement and rollers.
14) Fixed partitions.(Unsupported length of vertical member upto 1.5 mtr. Height of both ends of vertical member restrained but panels within 0.9 sq.m.)i) Top , bottom & side member.
15) Fixed partitions.(Unsupported length of vertical member upto 1.5 mtr. Height of both ends of vertical member restrained but panels within 0.9 sq.m.)i) Intermediate member
16) Fixed partitions.(Unsupported length of vertical member upto 1.5 mtr. Height of both ends of vertical member restrained but panels within 0.9 sq.m.)iii) Glazzing clip
17Supplying, fitting and fixing in position fibre glass panes of approvedquality with resin, nail, clip etc. as per IS:12866-1989. (In all floors for internal wall & upto 6 m height for external wall d) 3.0 mm thick (5.10 Kg/Sq.m) WindowWall
18Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) Wall Ceilling
19a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows,railing etc. fitted and fixed with necessary screws and lugs in ground floor.(Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25% for each addl. floor above 4th floor)(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
20Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparingthe surface throughly, complete as per manufacturer\"s specification andas per direction of the EIC. (In Ground Floor) (a) One Coat i) Water based interior grade Acrylic Primer
21Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) a) Normal Acrylic Emulsion
22a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. Grill
23A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : b) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
24Providing&fixingConcreteSignBoardasperIRC specification of size 900 x 750 x 37 mm. thick made with RCC1:1½:3withpakurvarietystonechipsreinforced withdoublelayerIRCfebric(75x75mm.mesh)and fixedwithnecessary nuts&boltsontwoRCprecast posts 100 mm. x 150 mm. of height 2.65 m. of which top 750mm.isofsection100x13mm.and1.90metre above GL & 0.75 metre below GL including digging hole, repackingthesamewithcement concrete1:3:6with jhamakhoaorwithlocalstonechipsetc.complete includingpaintingtwocoatsonbothfaceslettering signmarksetc.asperdirectionoftheEngineer-inCharge.(Therateisinclusiveofcostofreinforcement, concrete,shuttering,nuts&bolts,washeretc. complete.)
25Add GST @ 18 %
26Add Cess @ 1%

AI Tender Summary

OUR REF NO 43747981
AUTHORITY Local Bodies
TENDER VALUE 4.98 Lakhs
LAST DATE 22-06-2024
Authority
Authority Name Zilla Parishad
Work Description UPGRATION OF GP OFFICE BUILDING FIRST FLOOR(15th F.C) Activity ID-89394816
Basic Detail
Tender No WB/JAL/SADAR/P.G.P/01/24-25
Bidding Type Tender
Location
City paharpur
State West Bengal
Key Dates
Publish Date 18 Jun 2024
Submission Date 22 Jun 2024
Open Date 25 Jun 2024
Finance
Tender Value 4.98 Lakhs
Tender Fee Ref. Documents
EMD 3995
Exemption Not Available
Document List
BOQ_1513252.xls
Tendernotice_1.pdf
7710d2b7-3efe-4c36-b590-973cbf574d6c.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 18, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 22, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 25, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1513252.xls

pdf

Tendernotice_1.pdf

html

7710d2b7-3efe-4c36-b590-973cbf574d6c.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders