| 1 | Comprehensive maintenance and repairs to attened break down complaints on call and including stand by duty on the days of VIP visits for passenger lift of capacity 13 Passengers (884Kg), Make - KONI Elevator, maker\"s No. 11266, installed at Admin Building, (A- BLOCK) DIAT (DU) and MILIT, Girinagar including systematically examine lift periodically including all safety devices, selective / collective control along with control microprosser panel (V3F drive) and automatic rescue device,battery,governor,wire rope,lubricants,all doors,cabin lights,intercom system all as specified and directed by Engr in charge |
| 2 | All as per Item No. 1 here in before but 20 Passengers lift of capacity 1360Kg, Make - Konemaker\"s No. 11265. |
| 3 | All as per Item No. 1 here in before but 13 Passengers lift of capacity 884Kg, Make - Otis maker\"s No. 54KJ5951. |
| 4 | All as per Item No. 1 here in before but Goods lift of capacity 1818Kg, Make - OTISSl No. 52KJ5952. |
| 5 | All as per Item No. 1 here in before but Goods lift of capacity 1818Kg, Make - OTISSl No. 52KJ5953. |
| 6 | Comprehensive maintenance and repairs to attened break down complaints on call for passenger lift one number with capacity of 8 Passengers (544Kg), Make - Omega Elevator, installed at Deficient Md accn for civilian and service officers at DIAT (DU) and MILIT Girinagar including systematically examine lift periodically including all safety devices, selective / collective control along with control microprosser panel(V3F drive) and automatic rescue device,battery,governor,wire rope,lubricants,all doors,cabin lights,intercom system all as specified and directedby Engr in charge. |
| 7 | (a) Lift installed at Block No. P-322 ,Make - OMEGA Elevator, Sl No : 802079. |
| 8 | (b) Lift installed at Block No. P-323 ,Make - OMEGA Elevator, Sl No : 802080. |
| 9 | (c) Lift installed at Block No. P-324,Make - OMEGA Elevator, Sl No :802081. |
| 10 | (d)Lift installed at Block No. P-325, Make - OMEGA Elevator, Sl No : 802082. |
| 11 | (e) Lift installed at Block No. P-326, Make - OMEGA Elevator, Sl No : 802083. |
| 12 | Comprehensive maintenance and repairs to attened break down complaints on call for passenger lift one number with capacity of 8 Passengers (544Kg), Make - OMEGA Elevator, Sl No. 52KJ5951, installed at Point Hostel at DIAT (DU) Girinagar including systematically examine lift periodically including all safety devices, selective / collective control along with control microprosser panel(VVVF drive) and automatic rescue device,battery,governor,wire rope, lubricants, all doors, cabin lights, intercom system all as specified and as directed |
| 13 | (a) Lift installed at Points Hostel Block No-\"A\" Make - OMEGA Elevator, Sl No. 616/7018/LF/04 |
| 14 | (b) Lift installed at Points Hostel Block No-\"B\" Make - OMEGA Elevator, Sl No. 616/7019/LF/04 |
| 15 | (c) Lift installed at Points Hostel Block No-\"C\" Make - OMEGA Elevator, Sl No. 616/7020/LF/04 |
| 16 | Comprehensive maintenance and repairs to attened break down complaints on call for goods lift one number of capacity, (1000 Kg), Make – OMEGASl No 801059, installed at MCEA at R&DE (Engrs) Dighi Pune-15, including systematically examine lift periodically including all safety devices, selective / collective control along with control microprosser panel(V3F drive) and automatic rescue device,battery,governor,wire rope,lubricants,all doors,cabin lights,intercom system, all as specified and directed all as specified and directed. |
| 17 | Comprehensive maintenance and repairs to attened break down complaints on call for goods lift one number of capacity ,(1000 Kg),Make – Kone installed at Adm building at R&DE (Engrs) Dighi Pune-15, including systematically examine lift periodically including all safety devices, selective / collective control along with control microprosser panel(V3F drive) and automatic rescue device,battery,governor,wire rope,lubricants,all doors,cabin lights,intercom all as specified and directed by Engr in charge. |
| 18 | NOTE for Item No. 1 to 6 :-(a) All provision of Bombay lift Act as applicable shall be strictly complied with. |
| 19 | (b) Monthly maint / servicing shall be carried out in the presence of Rep of dept., R&D Girinagar or his representative.Necessary service report to be signed by Rep of dept. |
| 20 | (c) Any minor spares required for items coveredabove will be supplied and replaced by the firm at No extra cost. |
| 21 | (d) Any major spares required to complete the job shall be supplied by the Department. |
| 22 | (f) Cost of maintenance is inclusive of testing of lift from \"Lift Inspector\" once in Eleven months and necessary Test Report to be submitted by contractor to the Dept. |
| 23 | (g) In case of any break down the firm will be informed telephonically/ telegraphically and the same will be rectified by the firm with in 24 Hrs. |
| 24 | (h) In case of any major break down/ failure of safety measures, which can not be rectified within 24 Hrs the firm will inform Dept, Girinagar in writing and will stick stickers on each floor of lift indicating \"LIFT NOT IN SERVICE\". |
| 25 | (j) If firm fails to attend defects with in 24 Hrs of complaint recovery of Rs- 1000.00 Per day will be recovered. |
| 26 | Supply & Fix ARD for passenger/goods lift in including removingof old ARD andmakingliftservicable for smooth functioning all as directed by Engr-in-charge. |
| 27 | Supply & Fix Door drive for 8 passenger lift in including removing of old door drive andmakingliftservicable for smooth functioning all as directed by Engr-in-charge. |
| 28 | Supply & Fix door sensor forpassenger liftincluding removing of old door sensor andmakingliftservicable for smooth functioning all as directed by Engr-in-charge. |
| 29 | Supply & Fix Main (OSG) rope 8 mm for lift, including removing of old main rope andmakingliftservicable for smooth functioning all as directed by Engr-in-charge. |
| 30 | Supply and fix in replacement of Door Shoe (Gibs) for passenger/goods lift, including removing of old Door Shoer andmakingliftservicable for smooth functioning all as directed by Engr-in-charge. |
| 31 | Supply and fix in replacement of COP display including removing old COP display (forpassenger/goods lift) &makingliftservicable for smooth functioning all as directed by Engr-in-charge. |
| 32 | Supply and fix TOUCH LESS landing operating panel complete (LOP) with digital display for panel operate on 24 volt DC with SS plate complete all as specified and directed. |
| 33 | Supply and fix in replacement of 12 volt batteries for suitable Ampere andmakingliftservicable for smooth functioning all as directed by Engr-in-charge. |
| 34 | Supply and fix in replacement of emergency alarm 12 volt dc complete all as specified and directed. |
| 35 | Supply and fix in replacement of landing operating panel digital display making display serviceable all as directed by Engr-in-charge. |
| 36 | Supply and fix in replacement of door roller andmakingliftservicable for smooth functioning all as directed by Engr-in-charge. |
| 37 | Supply and fix in replacement of Door Accentric roller andmakingliftservicable for smooth functioning all as directed by Engr-in-charge. |
| 38 | Supply and fix contactor 110/220/440 AC/DC volt complete all as specified andall as directed by Engr-in-charge. |
| 39 | Supply and fix in replacement of relay 24 volts DC andmakingliftservicable for smooth functioning all as directed by Engr-in-charge. |
| 40 | Supply and fix in replacement of LED/CFL lights complete all as specified and directed. . |
| 41 | Supply and fix SMPS 5 volt/12 volt/24 volt DC and making lift serviceable complete all as specified and directed. |
| 42 | Supply and fix Landing Door Lock for lift and make lift serviceable complete all as specified and directed. |
| 43 | Supply and fix R CAM set for lift including removing of old RCAM and making lift serviceable complete all as specified and directed. |
| 44 | Supply and fix in replacement of COP display including removing old COP display and making lift serviceable complete all as specified and directed. |
| 45 | Supply and fix in replacement of Main Controller card (Mother Board) of control panel with all accessories, set all parameters of card and making lift serviceable complete all as specified and directed. |
| 46 | Supply and fix in replacement of Read Switch 12/24 volt DC complete all as specified and directed. |
| 47 | Supply and fix in replacement of new cabin fan as per existing make and size andmakingliftservicable for smooth functioning all as directed by Engr-in-charge. |
| 48 | Supply and fix in replacement of Relay card for Goods/Passengers Lift including removing old relay card make lift serviceableomplete all as specified and directed. |
| 49 | Rewinding of Break coil of main motor with super enameled copper winding wire of suitable gauges per existing varnishing, insulation, drying and testing complete all as specified and directed. |
| 50 | Supply and fix in replacement of limit switches complete all as specified and directed. |
| 51 | Supply and fix in replacement of car door belt with proper adjustment of belt make lift serviceable with complete all as specified and directed. |
| 52 | Supply and fix in replacement of MCB TP 32 Amps all as specified and directed. |
| 53 | Dismantling/ taking down burnt squirrel Cage Induction Motor of any capacity , 3 Phase, 415V, 1450 RPM of any make from its base and transporting the motor to the Contractor\"s workshop and back, refixing the motor at site after carrying out the following repairs/ renewals complete all as specified.-(i) opening the side covers and removing the rotor and cutting/ removing the burnt coils / winding from stator.(ii) Cleaning the slots carefully(iii) Rewinding the stator using super enamelled copper winding wire with same size, number of coils,number of turms/ coils as per data acquired from the old burnt motor, including varnishing two coats, drying and reassembling the electric motor at site(iv) Testing the coils for there continuity and no current passing through the stator core. |
| 54 | Supply and fix in replacement of Car Cabin and Counterweight frame shoe liner with complete all specified and directed. |
| 55 | Rewinding of Door Motor Dismantling/ taking down burnt squirrel Cage Induction Motor of any capacity , 3 Phase, 220V, of any make from its base omplete all as specified and directed. |
| 56 | Supply and fix Main Pulley/ Deflector Pully removing old pulley and making lift serviceable omplete all as specified and directed. |
| 57 | Supply and fix in replacement of TOUCH LESS car operating panel complete(COP) with digital display operate on 24 volt DC with SS plate complete all as specified and directed. |
| 58 | Supply and fix serial card on car top box for smooth functioning of lifts with all connected accessories of cards and connections complete all as specified and directed. |
| 59 | Supply and fix Governor/Governor Pulley of lift including removing old governor / governor pulley and making lift serviceable complete all as specified and directed. |
| 60 | Supply and fix COP Switch for passengers/ Goods lift including removing old button and making lift serviceable complete all as specified and directed. |
| 61 | Supply and fix LOP Switch for passengers / Goods lift including removing old button make lift serviceable complete all as specified and directed. |
| 62 | Disconnecting and taking out defective U/S main VVVF drive (any make) from existing control panel and supply and fixing new Main VVVF Drive upto existing KW complete with all electric Connection complete all as specified and directed. |
| 63 | Supply and Fix Emergency Light with UPS for lift in DIAT and MULTI complete all as specified and directed. |
| 64 | Supply & Fix Phase preventor for passenger/goods lift, including removing of old Phase preventor andmakingliftservicable for smooth functioning all as directed by Engr-in-charge. |
| 65 | Supply & Fix Toe guard for lift, including removing of oldToe guardandmakingliftservicable for smooth functioning all as directed by Engr-in-charge. |
| 66 | Supply & Fix Brake Set for lift, including removing of old Breack Set andmakingliftservicable for smooth functioning all as directed by Engr-in-charge. |
| 67 | Supply & Fix Pit Switch for lift, including removing of old Pit Switch andmakingliftservicable for smooth functioning all as directed by Engr-in-charge. |
| 68 | Supply & Fix Main rope 10mm forlift, including removing of old main rope andmakingliftservicable for smooth functioning all as directed by Engr-in-charge. |
| 69 | M&L for Anti Skid Anti Slip Rubber Mat Waterproof Jali Floor Mat for lifts complete all as specified and directed. |
| 70 | S & F MCCB250 Amp, FP, 415V, 50Hz, 36 KA confirming to IS/IEC 60947-2thermal magnetic adjustable with over load 80-100% & short circuit protection 5-10 Intypeall as directed by Engr-in-charge. |
| 71 | S & F MCCB 160 Amps, FP, 415V, 50Hz, 36 KA confirming to IS/IEC 60947-2thermal magnetic adjustable with over load 80-100% & short circuit protection 5-10 Intypeall as directed by Engr-in-charge. |
| 72 | S & F MCCB 63 Amps, FP, 415V, 50Hz, 25 KA confirming to IS/IEC 60947-2thermal magnetic adjustable with over load 80-100% & short circuit protection 5-10 Intype all as directed by Engr-in-charge. |
| 73 | S & F MCB TPN 63 Amp, 16 KA`C\" seriesthermal magnetic adjustable with over load 80-100%all as directed by Engr-in-charge. |
| 74 | Supplying and laying of DWC pipe 40 mm diaISI marked along with all accessories etc confirming to IS 14930, part II complete with fitting and cutting, jointing etc. in trench/open, for LT UG cable protection complete as required all as directed by Engr-in-charge. |
| 75 | Supply , laying , testing and connecting LT UG cables 1100 Volt gradeXLPE insulatedand PVC sheathed, armoured, with multi stranded aluminium conductor, heavy duty confirming to IS - 1554 part-I, including cable glands, cable lugs in LT panel/ FP Box etc including material and labour for all jointing/connecting material as required, cables laid in trenches/ducts/under plinth floors passing through pipes etc, for following sizes:-(a) 35 sqmm 3.5 core |
| 76 | (b) 25 sqmm 4 core |
| 77 | M & L for submain wiring alongwith earth wire with the following sizes of FRLSPVC insulatedcopper conductor single core cable, multistranded in PVC casing / caping on the surface or through and including suitable size ofPVC conduit on walls / roofs / ceilingwith its accessories all as specified and directed by Engr-in -charge for the following :- (a) 2X1.5 sq mm and 1x1.5 sq mm as earth wire |
| 78 | (b) 2x2.5 sq mm and 1x2.5 sq mm as earth wire |
| 79 | (c) 2x4.0 sq mm and 1x4.0 sq mm as earth wire |
| 80 | S & Fix Batten General purpose suitable for single LED Tubelight with integral LED driver, available in single / double side connection suitable for mount LED tube rod 1 x 18 watts including necessary electric connections 3 core 1 sqmm insulated copper wire from ceiling rose to tube light fitting complete all as specifed and directed by Engineer-in-charge. |
| 81 | S & Fix LED Tubelight (single side connection) with very high efficacy suited for installation in existing tubelight luminaire with G13 lamp holders to give glare free light with necessary fixing arrangement etc complete all as specifed and directed by Engineer-in-charge. |
| 82 | Supply, fixing & testing telephone system for lifts including telephone set,required wiring, hanging at suitable height complete all as required and directed by Eng-in-charge. |
| 83 | M&L for lathe/machining/cutting/ surfacing complete all as required at site & dirercted by Engr-in-charge. |
| 84 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out in soft loose soil complete all as required and directed by Eng-in-charge. |
| 85 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out in hard dense soil complete all as required and directed by Eng-in-charge. |
| 86 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as required and directed by Eng-in-charge. |
| 87 | Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as required and directed by Eng-in-charge. |
| 88 | M & L for rendering15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces and finished even and fair complete all as required and directed by Eng-in-charge. |
| 89 | M & L for applying 3 coats of white wash on new plastered surfaces double coat all as specified and directed by Engineer-in-charge complete all as required and directed by Eng-in-charge. |