BOQ
| Sl. No. | Item Description |
| 1 | Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) not exceeding 1.5 Sq.m each. |
| 2 | Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) exe 1.5 Sqm butnot exceeding 4.0 Sq.m each. |
| 3 | Refixing of shutters in same opening of any descrption after easing and adjusting ,n exc 1.50Sqm. |
| 4 | Refixing of shutters in same opening of any descrption after easing and adjusting , exc 1.00Sqm but n exc 2.00 Sqm. |
| 5 | MS Fastner of size 200 to 250mm for fixing wooden door / window frame and like in postion |
| 6 | S & F forFactory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made |
| 7 | S & F forFactory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made |
| 8 | M&L 30mm thick Factory made solid WPC (Wood plastic composit) moulded gauged door shutter with wire mesh in any number of division with brown wood grain texture, including S.S wire mesh shall be fixed with 15x15 square tube in side rails with screwing 8x28 heat metal zink coated screws can be remove or fix again after changing of wire mesh when needed. The density of the shall be as per manufacture instruction complete all as specified and complete all as specified and directed.Make:- ENCHON (Kumar Arch Tech Pvt Ltd)/FLORESTA/ARCHIDPLY |
| 9 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of EngineerIn- Charge. Note- S S Butt hing measured and paid separately at relevant item |
| 10 | Providing and fixing of vajra series windows made of pre-painted steel (Base steel as per IS 513 of 0.58 mm thick \"D\" Quality galvanized as per IS 277 with zinc of 120 GSM) primer coated with epoxy primer of 5-7 microns thick,finished painted with a polyester paint of 12-16 micons thick and back coated with 5-7 microns thick alkyd backer.section for outer frame should be of 75*55 mm ,section for fixed glass beading should be of 12*12 mm and section for shutter should be of 52*25mm. Outer frame & mullion sections to have rebate for glazed for glazed shutters,fly mesh shutter section should be of 20*40mm. The sections are to be cut to lenght mitre jointed with corner brackets.Centre mullions to be fixed with mullion cap.Elixir or equivalent stay,handles 2 no of heavy -duty stain less steel pivot hinges shall be provided per shutter.The windows should be panelled with 4 mm thick plain float glass and S.S Mesh for fly mesh shutter(304 grade). Rubber Gaskets are provided all around the glass.The above frames be fixed to the concrete/masoary wall by means of self-expanding,screws, including 10mm square guard bars 6\" (152.4mm) pitch,complete for finished Item of work. |
| 11 | Demolition of lime concrete in floors and paving exe 15 cm thick above ground floor (sunken floor)including picking, sweeping cleaning with wire brush and washing down with water to remove dust, dirt to get surface free of laitance , scales, oil or any othet loose material andremoving the demolished material outside the MOD land.Complete all as specified and directed |
| 12 | M/L for PCC 1:1.5:3 type A-0 (Using 12.5mm stone aggregate)as in concrete angle-fillets with a radiaus of 75mm shall be provided at junctions between roofs, floor and vertical faces of walls (parapet, pillar for water tank staging and sunken floor) around obstacles such as pipes, chimney stacks, etc. and other similar situation to ease up about corners mixed with Liquied water proffing compound (as per manufactur direction )Note :- water proffing compound will be measured and paid seperately.. |
| 13 | Providing and application two coat of acrylic polymer modified cementitiousflexible waterproof coating on horizontal and vertical surface for sunken floor as per manufacturer direction after base preparation of cleaning, brushing and removal of flaky materials. The coatings shall be applied at intervals and as per the manufacturer’s specifications and approved by Engineer in Charge .Note : Ponding test after water proofingcoating willl be done for ponding for 48 Hrs . |
| 14 | M/L for 15m m thick potection plaster CM 1.4 floor and wall with plolymer modified repair mortar (SBR Latex liquid polymer as per manufactur direction). Complete all as specfied and directed. Note: The reates of SBR quoted shall deemed to be included for these items. |
| 15 | M/L for providing 40 mm dia GI pipe (medium grade) spout projecting at least 300 mm beyond outer face of wall or as per direction of Engr-in-charge |
| 16 | M&L for cementconcrete 1:7:12 type F2(using 40 mm graded stone aggregate)as in filling of sunken portion complete all as specified and directed.Complete all as specified and directed |
| 17 | M&L for 30 mm thick PCC Type B-0, 1:2:4, (using 12.5 mm graded stone aggregate)as in floormixed with SBR Latex liquid polymer as per manufactur direction.Complete all as specified and directed Note :- The rates of SBR quoted shall deemed to be included for these items |
| 18 | S & F for stainless steel barrel tower bolt of200 mm lengthofextruded section (ISI Marked). Complete all as specified and directed |
| 19 | S & F for stainless steel barrel tower bolt of300 mm lengthofextruded section (ISI Marked). Complete all as specified and directed |
| 20 | S & F, in repair,for stainless steel barrel tower bolt of300 mm lengthofextruded section (ISI Marked). Complete all as specified and directed |
| 21 | S&F forstainless steel handles,fabricated type, anodised 200 mm long,(ISI Marked)all as specified and directed. |
| 22 | S&F forstainless steel handles,fabricated type, anodised 125 mm long,(ISI Marked)all as specified and directed. |
| 23 | S&F, in repair, stainless steel handles,fabricated type, anodised 200 mm long,(ISI Marked)all as specified and directed. |
| 24 | S & F for stainlees steel sliding door bolt of 300mm long, with hasp, staple (bolt type) complete all as specified and directed. |
| 25 | S & F for stainlees steel sliding door bolt of 300mm long, with hasp, staple (bolt type) complete all as specified and directed. fixed in repair. |
| 26 | S&F Stainlessnon megnetic steel butt hinges of size 100mm.(ISI Marked). Complete all as specified and directed by Engineer in Charge |
| 27 | S & Ffor Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor over all length of cover plate 150 mm. |
| 28 | S&F 300mm mild steel ordinary rat tail rod pattern springs, including roller and roller plate complete. |
| 29 | S&F in repair 300mm mild steel ordinary rat tail rod pattern springs, including roller and roller plate complete. |
| 30 | S & F for Stainless steel wire cloth of size 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples, fixed in repairs. |
| 31 | M & L in repairs for Plain fillets of second class hard wood (suitable for joiner’s and carpenter’s work, locally available) section area exceeding 3 Sq.cm and not exceeding 6 Sq.cm, square, rectangular or triangular in section, clean sawn secured with nails. |
| 32 | S&F in repairs for stainless steel non magnetic curtain rod 20 mm dia with fixing brackets and decorative type knobs both side of each rod.Note: - Measurement will be taken between end point of knobs” |
| 33 | S & F in repairs of aluminiumdoor seal upto 1200 mm long onbottom of door |
| 34 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames glazed with putty or fixed with beads or from metal frames including punching or drilling out old glazing pins /spring clips and providing and fixing new one. |
| 35 | S & F for Glazing with figured glass (Frosted), pin head type, 4 mm thick and glazing with oil puttyor aluminium or PVC beading insquares notexceeding 0.5 Sq.m in each pane. |
| 36 | S & F for Glazing with plain sheet glass, ordinary quality, 4 mm thick and glazing with oil puttyor aluminium or PVC beading insquares notexceeding 0.5 Sq.m in each pane. |
| 37 | S&F in repairs S S peg set, 150 mm complete all as specified and directed. |
| 38 | Dismantlingfloor hearth or wall tiling including cement mortar bedding (but not backing), removingand rubbish off the premises from MoD all as specified and directed. |
| 39 | M&L for Non- skid coloured ceramictiles of any design and pattern, 300X300X7 to 8 mm thick, in floor etc incl 15mm thick screed bed in CM 1:6, Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles.Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects.Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE.Complete all as specified and directed |
| 40 | M&L for coloured glazed ceramic tiles of any design and pattern, 300x450x 7 to 8 mmthick, as in dado etc incl 10 mm thick rendering in CM 1:4, Set and jointed in neat cement slurry and pointed in white of coloured cement to match the shade of the tiles . Tiles shall be confirming to IS-15622:2017, Group B III with average water absorption between 10% to 15%. Length, width and straightness of sides + 0.20% (Max deviation). Thickness + 4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (Max Deviation). surface flatness + 0.22% (Max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects.Note: Shade of the tiles including Colour, design and pattern shall be got approved by AGE(I).Complete all as specified and directed |
| 41 | Dismantling of cast iron or reinforced concrete drain pipes up to 110mm dia , jointed in cement mortar and taking out of trenches if required . |
| 42 | S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches or in floors. |
| 43 | S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches or in floors. |
| 44 | S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls. |
| 45 | S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls. |
| 46 | S & F 75 mm bore PVC (SWR) bends of any radius |
| 47 | S & F 75 mm bore PVC (SWR) bends of any radius with access door |
| 48 | S & F 110 mm bore PVC (SWR) bends of any radius |
| 49 | S & F 110 mm bore PVC (SWR) bends of any radius with access door |
| 50 | S & F PVC (SWR) reducers of size 110 mm x75 mm |
| 51 | S & F 75 mm bore PVC (SWR) junction single (Single `T\") equal or unequal with access door. |
| 52 | S & F 110 mm bore PVC (SWR) junction single (Single `T\") equal or unequal with access door. |
| 53 | S & F 75 mm bore PVC (SWR) Vent Cowl |
| 54 | S & F 75 mm bore PVC (SWR) Multi floor trap including jointing with solvent cement |
| 55 | S & F 110 mm bore PVC (SWR) P Trap |
| 56 | S & F 75 mm bore PVC (SWR) floor Trap, plain with grating inclding jointing with solvent cement . |
| 57 | S&F stackclamps out of 40mmx 3 mm flat iron includingbolts and nuts and securing ends of stays to walls or roof with fastner for 100 mm pipe, complete all as specified and directed. |
| 58 | S&F stackclamps out of 40mmx 3 mm flat iron includingbolts and nuts and securing ends of stays to walls or roof with fastner for 100 mm pipe, complete all as specified and directed. |
| 59 | Demolition of Stone slabs and tiles of any description or thickness in floors, approns, kitchen plateform / shelvesetc.Complete all as specified and directed |
| 60 | M & L of 18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including ointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. |
| 61 | Demolition of brick work built in cement mortar in any description and position complete all as specified and directed. |
| 62 | Brick work with sub-class `B\" bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 |
| 63 | Brick work with sub-class `B\" bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6, except brick work |
| 64 | Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia . |
| 65 | Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 15 mm dia . |
| 66 | M&L for Mild steel galvanized steel tubing of 20 mm bore (ISI Marked) with screwed socket joints, medium grade, together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugsor laid in floors Complete all as specified and directed |
| 67 | Refixing old steel tubing of 20 mm bore and connections in new or old position (walls, ceilings, floors etc.) together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugsor laid in floors Complete all as specified and directed |
| 68 | M&L for cutting chases on brick or concrete surface for concealed water tubing or / similar work ofgirth n.exc 10cm including making good of disturbed surfaces with PCC 1:2:4 type B0 using 12.5 mm graded aggregate complete all as specified and directed. |
| 69 | M&L for Mild steel galvanized steel tubing of 15 mm bore (ISI Marked) with screwed socket joints as in concealed pipe work ,medium grade, together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugsor laid in floors Complete all as specified and directed |
| 70 | S & F in repairs Sinks with drainage board made of stainless steel 0.8mm thick kitchen or laboratory with plugs, washers; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 914 mm x 460 x 203 and bowl size 405mm x 354 mm x 203mm.Make - Blue Star Silver Shine Cat No- SSSBSD-52, Nirali (Elegance NG) Small & Prayag Cat Part No. 1239 D |
| 71 | S & F in repair to Stainless steel kitchen plate rack 0.80mm thick sheet of over all size 31\" x 30\" x 10\" fixed with steel screws and steel rawal plugs“Make – Prayag Cat Part No- P 346 , Blue star silver shine Cat No-SSKPR-314)” |
| 72 | S & F in repairs 15 mm bore Stop valves (angular stop cock), cast copper alloy, fancy type, chromium plated with long shank and cupscrewed down high pressure with crutch or butterfly handleor concealed screwed both ends for iron pipe or for unions. Make - Jaquar Cat No-MQT-526NKN, Hindware cat No-F200005 ,Prayag Cat No-6510 |
| 73 | S & F in repairs Stop anglevalves, cast copper alloy, fancy type chromium plated with long shank and cup (concealed type) of size 15mm bore, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe completeMake - Jaquar Cat No-MQT-514AKN, Hindware cat No-F200007 ,Prayag Cat No-6518 |
| 74 | S & F in repairs 15 mm bore chromium plated bib taps long body, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule. Make - Jaquar Cat No-MQT-512KN, Hindware cat No-F200001 ,Prayag Cat No-6502 |
| 75 | S & F in repairs 15mm bore pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly nuts, screwed for iron pipe. Make - Jaquar Cat No-MQT-508KN, Hindware cat No-F200011 ,Prayag Cat No-6509 |
| 76 | S&F in repairs towel Rail 600 mm long fixedwith and including Chromimum plated brass screws and wooden plastic cleats (Min weight 190 gms). Make - Jaquar Cat No-AEC 1111N, Hindware cat No-F880005 ,Prayag Cat No-BA-01 |
| 77 | S & F in repairs Chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing tosteel pipe or union |
| 78 | S&F in repair for PVC Connections 15mm size with PTMT nuts of length 600 mm |
| 79 | S&F in repairWash basins (Padestal pattern) 550x400mm vitreous china (flat back type) any size incl cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe but including waste fitting. Make- Jaquar Cat No-ECS-WHT-801 (WHB) & ECS-WHT-301(PEDESTAL), Hindware Cat No-Mario 10087 (WHB) & 11003(PEDESTAL) ,Cera Cat No-S2040120(WHB) & S2090113(PEDESTAL) |
| 80 | S&F in repairWash basins 550x400mm vitreous china (flat back type) any size incl cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe but including waste fitting |
| 81 | S & F in repairs for Grating ,round 127 mm diachromoum plated |
| 82 | S&F in repair to 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers |
| 83 | S&F in repairs PVC valveless, syphonic action type flushing cistern (Dual action ISI Marked), lowlevel , white, with inlet ball valve, float and handle including brackets and flush pipe suitable for IWC of polyethylene of low or high density or PVC 32 mm dia for low level cistern for 10 litres capacity of approved make .Complete all as specified and directed . Make- Sleek fresh dual flush of Hindware Model No star white size 47.6x15.5x32,Parryware Cat No 8177*, CeraCat No B1810110 |
| 84 | S&F in repairs Vitreous china Squatting pan , \"Orissa pattern, size 580x440 mm white, with integral foot restexcluding flushing cistern and flush pipe including connection to trap, to flushing pipe, anti-syphonage pipe, etc complete including making good to floor . |
| 85 | S&F in repairs Vitreous China wash down water closet pan (Pedestal pattern) white complete incl seat and cover, flush pipe incl all joints complete |
| 86 | M & L in repair S S Jet spray with 1.5 mtr braided tube complete all as specified and directed |
| 87 | S&F 15 mm dia brass chromium plated central hole wash basin mixture, fancy type with or without lettered \"Hot\" or \"Cold\" ,with long screwed shanks and fly nut capstanhead screwed for 15mm dia pipe fixed in repair. Make- Jaquar Cat No-MQT-516AKN, Hindware cat No-F200014 ,Prayag Cat No-6550 |
| 88 | Supply & fix in repair wall mixer with over head shower chromium plated for mixing hot and cold water screwed for iron pipe suitable for 15mm borepipes complete all as specified and directed. Make- Jaquar Cat No-MQT-517BKN(wall mixer) ,EOS-542A(Shower) & ALE-536A(Shower arm, Hindware cat No-F200020 (wall mixer) & F160120 (shower with arm) , Prayag Cat No-6575 (wall mixer),& BS-36(Shower with arm) |
| 89 | Supply & fix in repair to chromium plated towel ring complete all as specified Make - JaquarCat part no AEC-1121N , Hindware cat No-F880007, &Prayag Cat No-BA 02 |
| 90 | S&F in repair 32 mm dia lowdensity polyethylene pipe (LDPE) of pressure rating @ 6Kg f per Cm Cm Square fixed to walls, ceilings or in floors etc. |
| 91 | M&L for preparation of old decorated surface of internal wall by removing existing treatment with mechanical sander (rpm 1500-2700)along with internal dust extraction system for clean environment certified by reputed paint manufacturers and applying two coats of acrylic distemper over one coat of wall puttyusing roller all as specified and prescribed by manufacturer of paint Ist Quality and all as directed at site by Engr-in-Charge.Note:- (i) The old surface must be prepared with wall care putty in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper.The cost of materials, labour & T&P required for preparation of surface are deemed to be included in the rates quoted.(ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor.The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture.(iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building.(v).The colour / shade will be all as approved by GE / AGE (I) |
| 92 | Taking down cement plaster on brick , concrete or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water and removing unseviceable materials out side MoD land complete all as specified and as directed. |
| 93 | M&L for 15mm thick plastering on fair faces of brick wall in CM (1:6) surface finished even and fair complete all as specified and directed. |
| 94 | M&L for preparation of newly plastered surface of interior wall by application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer using roller all as specified and prescribed by manufacturer of paint/ distemper by using roller/ spray machine complete all as specied and directed at site by Engineer-in-Charge.Note:- (i) The old surface must be prepared with wall care putty in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper.The cost of materials, labour & T&P required for preparation of surface are deemed to be included in the rates quoted.(ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor.The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture.(iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building.(v).The colour / shade will be all as approved by GE / AGE (I) |
| 95 | S&F bib taps 15mm bore of standard PTMT any colour ahigh pressure screwed for iron pipe and fixed in repair (Minimum weight 15mm-90gms/20mm- 125gms). |
| 96 | S&F pillar taps 15mm bore of standard PTMT any colour ahigh pressure screwed for iron pipe and fixed in repair (Minimum weight 15mm-90gms/20mm- 125gms). |
| 97 | S&F in repair 20 mm diaballvalves, high pressure of epoxy coated Aluminium rod and high density plastic ball complete including check nut and suitable nipple, screwed for iron pipes or brasas ferrule and fixed.Make : ISI mark |
| 98 | Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealedPVC conduit,medium grade(ISImarked) ,duly concealed on wall/ceiling or above false ceiling with fittings not less than 20 mm dia medium grade(Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including whitecover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates.ii)If the contractor fail to make good the disturbed surface of wall/ceiling etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding. |
| 99 | All as per above item No.1but One 3 pin/5 pin 5/6 Amps socket outlet on same board with other switches, with cables 1.5 Sqmm size, complete all as specified and directed. |
| 100 | All as per above item No 1 but forOne 3pin/5pin 5/6 Amps socket out let onindependent board with other switches, with cables 1.5 sq mm size,complete all as specified and directed . |
| 101 | All as per above item No.1abovebut with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point with contineous earth wire of 2.5 Sqmm complete all as specified and directed . |
| 102 | S & F switch Modular single pole,one way 6 Amps , 1 module,230 volts, 50 hzall as specified and directed by Engr-in-Charge.Make: Legrand / Indoasian L&T/ Cona |
| 103 | Supply and fixing switch modular , one-way 16Amps,1 module 240 Volts ACall as specified and directed by Engr-in-Charge.Make: Legrand / Indoasian/ L&T/ Cona |
| 104 | Supply and fixModular Socket outlet, 6A - 3 pin, 2 module ISI marked, 230 volts, 50 hz all as specified and directed by Engr-in-Charge.Make: Legrand/ Indoasian/ L&T/ Cona |
| 105 | Supply and fixing modular socket, 6A/16A -2/3 pin combined 2 module230 volts, 50 hz all as specified and directed by Engr-in-Charge.Make: Legrand/ IndoasianL&T/Havells |
| 106 | Supply and fixing switch modular typesingle pole, two way 6 Amp, 1 moduleISI marked, 230 volts, 50 hz all as specified and directed by Engr-in-Charge.Make: Legrand/ Indoasian/ L&T/ Cona |
| 107 | Supply and fixing bell push modulartype single pole one way 6 Amps, 1 module with with indicator, ISI marked all as specified.Legrand, Indoasian, L&T, Cona |
| 108 | Supply and fixing in repair Fancy angle holder Metal ring insulated body with back plate, suitable for batten fittings all as specified and directed.Anchor, Cona, Havells |
| 109 | Supply and fix in repairs /replacement switch piano 230 volts, AC, flush typesingle pole, one way 5/6 Amps ISI marked all as specified and directed.Anchor,Cona , Havells |
| 110 | Supply and fixin repair/replacement switch piano 230 volts,AC, flush type white /ivory finish 15/16 Amps single pole one way-ditto-.Anchor,Conaor equivalent in Havells. |
| 111 | Supply only in repairs/replacement, socket out let3/5 pin 5/6 Ampsflush type Anchor,cona or ,Havells . |
| 112 | Supply and fixing in repair socket outlet 5/6 pin 5/15 amp flush type multi suitable for 240 volts AC all as specified and directed of ISI markedAnchor,cona or equivalent inHavells . |
| 113 | Supply and fixing in repair batton/angle holder insulated body with back plate, suitable for batten fittings all as specified & directed. |
| 114 | Suupply and fixing in repair step socket type fan regulator 120/280 V , ISI marked all as specified and directed by Engr-in-Charge. |
| 115 | Supply and fixing sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 8 way with 200 Amps rated bus bar all as specified and directed .Make- legrand / ABB/ Schnider/L&T/Siemens |
| 116 | Supply and fixing MCBSPN 32 Amp 240 V AC 10 KA \"C\" Curve repturingcapacity all as specified. Make -Legrand, ABB, Schnider |
| 117 | Supply and fixing MCBSP 5 to 10 Amp \"B\" series 10 KA repturingcapacity complete all as specified. Make -Legrand , ABB/ Schnider/L&T/Siemens |
| 118 | Supply and fix new LED building security light 1 x 25 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF> 0.98 having overvoltage protection upto 440 volt, surge protection level > 10 KV, thermal short circuit prtection THD< 10% made up of long life LED chip (SMD) in modular with Ra< 70, and LED lumen efficiency > 120 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminaire efficiency> 120 luminous /watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500 K including fixing on existing bracket including making necessary electricconnection with 1.5 sqmm , 3 core, PVC insulated copperonductor cable 1100 Volt grade complete all as specified and as directed by Eng-in-Charge |
| 119 | Supply and fixing sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/concealed in wall along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FR LSH) as earth wire and wire connected withmain earth dolly including cuttingchasesand making good disturbed portionall as specified and directed . Note: Two runs of phase, netural wire and one run of earth wire and PVC conduit will be measured as one RM or one length. |
| 120 | Dismantling and taking down U/Spoint wiring of any type (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box excluding conduit when in wiring in existing conduit, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed.Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding. |
| 121 | Dismantling and taking downu/s sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc excluding conduit when in wiring in existing conduit complete all as specified & as directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding. |
| 122 | Dismantling and taking down old damaged existing DB’s any type and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc.complete all as specified |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender