Tender For External Electrification And Street Lighting Work In The Area Of Pmay At Sector-15 Manjhola Yojna No.4 Part-Ii (Vistar) Moradabad., 1 External Electrification Work 2 Supply and Erection of Double Pole Structure made of following types of support duly grouted in 1:4:8 cement concrete (1 cement, 4 coarse sand and 8 grit of 20mm nominal size) plinthed, plastered & painted in the same manner as already specified for respective supports suitable for plinth mounted type substation with different types of M.S. Channel and angle iron duly fabricated for disc fittings D.O. fuse set, TPMO ladder stand projecting outside dropper and bracings , including cost of all material, labour and T & P required for proper completion of work as per drawing and direction of E/I. (Only Manufacturers Whose Latest GTP Approved in PVVNL.) 3 With 11 Mts. long 410 SP 55 S.T. Pole 4 Supply and Erection of 11 KV TPMO set complete in all respects as per Direction of E/I. 5 Supply and Erection of 11 KVD.O. fuse set complete in all respects as per Direction of E/I. 6 Supply and fixing of H.T./L.T. jumpering and connections on double pole/four pole, lightening arrestor and transformer. The rates include the cost of all materials, labour and T & P etc. required for proper completion work. 7 Supply Installation, Testing and commissioning of 11 /0.433 KV Transformer of following capacity as per BIS 1180-2014 Standard. The rates also including loading, unloading, local carriage and T & P charges etc. Make:- MODERN/TRANSTRON/ELECON (Whose Latest GTP Approved in PVVNL Having Valid CPRI/ERDA Type Test Report) 8 400 KVA, 11/0.433KV (Level-1) 9 Supply, installation, testing and commissioning of Outdoor Type,dust and vermin proof weather proof with rain canopy on four sideswith locking arrangement, 800A ACB L.T Panel Fabricated out of 2.0mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer in charge after proper sheet treatment process of sheet steel. All indicating lights shall be LED type and all wiring shall be done from PVC Insulated copper flexible wire. The panel shall be completed in all respect and shall consist of following material.Incomer: 800A A F.P Manual Fixed type A.C.B with Metering (ie Ameter with ASS, Voltmeter with VSS) along with, Phase Indicating Lights, CT,Control MCB etc. -1 Set Panel will have suitable rating (1Amp/Sqmm) of Aluminium Bas bar for Proper Temination of Cables. ( minimum 400 sqmm6 nos )All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports. Make:-ABB/ Schneider/Seimens or as Directed by E/I. 10 800A 11 S/F of lightening arrestor set (3 Nos.) suitable for mounting on steel supports complete with all materials, labour and T & P required of proper completion of work as per direction of E/I. 12 Supply & Erection of TPN Distribution Pillar Fabricated with Wire Clad Dust and Vermin Proof as per Drawing consisting suitable size of Copper Bus Bar 60 x10mm or Equivalent sectional area consisting Henleys Pattern fuse unit set complete as follows, Metallic Pillar shall be made of 14 SWG MS Sheet on frame of angle Iron size 35x35x5mm Duly painted with 2 Coat of approved paint over rust resisting primer both side locking arrangement and handle & Danger Board complete with suitable masonary plate-form for mounting the pillar. The Pillar shall have earthing terminals as per Direction of E/I.(Only PWD & CPRI Approved Make) 13 Incoming : Two (2) Nos. 500 Amp.Fuse unit 14 Outgoing : Two (2) Nos. 500 Amp.& Two (2) Nos. 300 Amp.Fuse unit 15 Supply, Installation, Testing & Commissioning ofDistribution Pillar. The Feeder Pillar shall be fabricated out of 2.0mm thick CRCA Sheet steel duly painted with powder coated paint. The Feeder Pillar shall be suitable for Outdoor Installation & shall confirm to minimum IP:55 degree of Protection. The Bus bars shall be of Aluminium, Electrolytic Grade only. Maximum design density shall not be exceed 1 Amp./sqmm. All Busbars shall be insulated with coloured heat shrinkable PVC Sleeved. All Busbar supports shall be non hygroscopic DMC/SMC Supports. The Feeder Pillar shall be completed in all respect as per Direction of E/I. (Only PWD & CPRI Approved Make) 16 Incoming : Two (2) Set 300 Amp. TPN HRC Fuse Unit 17 Outgoing : Five (5) Set 200 Amp. TPN HRC Fuse Unit 18 Busbar : One (1) No.300 Amp. TPN Aluminium Bus bar of Suitable length 19 Construction of fencing plinth of following sizes in Ist class brick work including plaster and providing flat bricks soling and pointing the same with 1:2 cement and fine sand mortar over 75mm thick cement concreting in the ratio 1:6:12 in open space of the cage as per direction of E/I. 20 6x4x0.23m for Substation 21 Supply of fixing of 2.45M. High cage fabricated with 3.0mm thick expanded metal/wire mesh of equivalent weight fixed on 50x50x6mm angle iron frame having vertical members spaced at 1.0M to 1.25M. and horizontal members spaced at 1.20M the vetical members shall be grouted in ground and horizontal members in the wall to a depth of 300mm with ends folded. The cage shall have 1000x2000mm size single leaf door with locking arrangement having door frame fabricated with 35x35x5mm angle iron and 3mm expanded metal wire mesh of equivalent weight duly fixed with the cage member. The cage shall have nut bolt arrangement for opening the sides by providing tees 45x20cm of angle iron size 50x50x6mm as per direction of E/I. It shall be painted with red oxide primer and synthetic enamelled paint as per direction of E/I. including all materials, labour and T & P for proper completion of work.PWD SOR 2018 SI No. 1142 22 Supply and Burring of Safe Earthing Electrode T-39 Zn-Zinc Coated, Length 3000 mm, outer pipe 76.30 mm x 3.2 mm inner pipe 42.40 mm x 2.6, terminal Dia 12 mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square CI frame with hinged cover & masonary housing (From electrode terminal to switch board, cost of 25 x 3 GI Strip will be extra) UP PWD SOR-2018 S.No. 726 (D) 23 Construction of plinth for Transformer size 2.0x1.25x1.0 Complete With all materials, labour and T & P required for proper completion of work as per specification drawing and direction of E/I. 24 Supply of following size of Al. conductor XLPE Insulated, Cores Laid up, PVC Innersheathed, Armouredwith Galvanised Al. Strip Extruded PVC Type ST2 Outer Sheathed, 650V/1100 Volt Grade as per IS 7098 (Part I) 1988 With up to date Ammendments. Make:- POLYCAB/ GLOSTER/FINOLEX / HAVELLS/ KEI/ UNIVERSAL 25 120 Sqmm 3½ core 26 185 Sqmm 3½ core 27 Supply and laying of following size of Al. conductor PVC insulated armoured, served sheathed cable 1100V grade at a depth of 75cm. below ground level over a cushion of 75mm thick sand alround and protected with brick on sides And Top. On surface the cable run shall be fixed on M.S. clamp etc.of suitable size or as directed by the E/I. complete in all respect. The armouring of cable shall be properly connected with earth conductor by clamp etc. as per PWD SOR 2018 S.No. 501(t) Make:- POLYCAB/ GLOSTER/FINOLEX / HAVELLS/ KEI/ UNIVERSAL 28 400 Sqmm 3½ core 29 Supply and fixing of palm or pin copper tin plated cable socket (lugs) to the cable leads insulating with tape and making connections etc. complete in all respects as per PWD SOR 2018 S.No. 504 (h ), ( i) , ( j), ( l),(m) & ( o ) 30 70 Sqmm 31 95 Sqmm 32 120Sqmm 33 185Sqmm 34 240 Sqmm 35 400 Sqmm 36 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouribg of the cable shall be properly connected with the earth as per direction of Engineer-Incharge.as per PWD SOR 2018 S.No. 503(0 ), ( q) & ( t) 37 120 Sqmm 3½ core 38 185 Sqmm 3½ core 39 400 Sqmm 3½ core 40 S/F of following type of G.I. pipe B class for cable clamped with supports by 3 Nos. clamps made of 20x3mm M.S. flat and suitable size of nut bolt and washer required for proper completion of work as per direction of E/I. Make:-TATA/SAIL/JINDAL 41 80mm dia 42 100mm dia 43 S/Erection of 11 KV section Four Pole (Bottom section Galvanised) structure made of following types of supports duly grouted. Plinthed plastered and painted in the same manner as already specified for respective supports with 4 nos. M.S.channels of size 100x50mm & 4 nos. channels of size 75x40mm , 9 no. 11 kv Pin Insulator and 8 Nos. bracing of angle iron size 65x65x6mm 3M length fixed with packing piece and bolt and nuts as required including cost of material, labour and T & P required for proper completion of work as per direction of E/I. (Only Manufacturers Whose Latest GTP Approved in PVVNL.) 44 11 Mts. longSP-55 S.T.pole 45 S/Erection of 11 KV section Double Pole (Bottom section Galvanised) structure made of following types of supports duly grouted. Plinthed plastered and painted in the same manner as already specified for respective supports with four nos. channels of size 100x50mm M.S. channel, 3 no. 11 kv Pin Insulator and 2 Nos. bracing of angle iron size 65x65x6mm 3M length fixed with packing piece and bolt and nuts as required including cost of material, labour and T & P required for proper completion of work as per direction of E/I. (Only Manufacturers Whose Latest GTP Approved in PVVNL.) 46 11 Mts. longSP-55 S.T.pole 47 Making suitable Earth of H.T. overhead line pole with 2.5 Mts. long 20mm M.S rod connected with 7/16 SWGG.S. wire duly clamped & binded on pole including the cost of materials, labour and T & P required for proper completion of work as per direction of E/I. 48 Supply of following size H.T. cable standered compacted circular Al. conductor screen with Extruded Semi conducting compound, XLPE insulated in copper Tape, cores laid up to innersheath of PVC, Galvanised Steel Strip Armoured & overall sheathed cable confirming to IS 7098 (Part-2) 2011 with upto date Ammendmentscomplete in all respect as per Direction of E/I. Make:- POLYCAB/ GLOSTER/FINOLEX / HAVELLS/ KEI/ UNIVERSAL 49 120 Sqmm 3 core 11 KV 50 300 Sqmm 3 core 11 KV 51 S/F and jointing of 11 KV jointing kit (Heat Sink) per XLPE cable including cost of all material Labour and T & P as per proper completion of work as per direction of E/I. Make (Raychem/3M/Densons) as per DSR 2022 S.No.10.5.2, 10.4.2, 10.5.4 52 120 Sqmm3core Outdoor 53 120 Sqmm3core Indoor 54 300 Sqmm3core Outdoor 55 Supply of HDPE pipe upto PN-6 working pressure Rating material Grade PE-80 Nominal dia (OD) 110 mm 6.50 mm thicknesscomplete in all respect as per relevants I.S. Technicals specification. 56 Digging & Refilling of Same Trench Parallel to Road at a depth of 1.5 Mtr. as required & laying charges of cable & different size HDPE Pipe (PN-6 PE 80 Grade) complete with all material, labour and T&P etc. required for proper completion of work as per Direction of E/I. 57 Supply of HDPE pipe upto PN-6 working pressure Rating material Grade PE-80 Nominal dia (OD) 160 mm 9.50 mm thicknesscomplete in all respect as per relevants I.S. Technicals specification. 58 Drilling of Road Parallely & Road Crossing at a depth of 2 to 3 Mtr. as required & laying charges of cable & 160mm Dia HDPE Pipe complete with all material, labour, Drilling machine & required T&P etc. required for proper completion of work as per Direction of E/I. 59 S/F of danger board (H.T.) size 200x250 mm at suitable height of pole as per direction of E/I 60 S/F of barbed wire (1.5kg) duly clamped with 20x3mm M.S. flats at both ends on steel poles at suitable height as per direction of E/I. 61 S/F of cable route marker made of 1:2:4 R.C.C. Block size 1000x400x10 mm grouted with 1:3:6 cement stone grit coarse sand 30cm below G.L. with painting numbering & marking etc. complete with all required material T&P etc. complete in all respects as per direction of E/I. 62 Street Lighting Work 63 Supply & fixing of 7mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thick) having 3mm thickness with Single arm bracket (1Mtr length) onRCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P complete in all respect. UP PWD SOR 2018 SI No-641 Make:-Bajaj/Vallmont/RRISPAT CONSOUL 64 Supply & fixing of 9mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 155mm and base plate 12mm thick) having 3mm thickness with Single arm bracket (1Mtr length) onRCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P complete in all respect. UP PWD SOR 2018 SI No-641 Make:-Bajaj/Vallmont/RRISPAT CONSOUL 65 Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser/Reflector with Complete driver set suitable for 30 to 40 watt. Confirming to IP 66 Protection Including Street light Bracket (60 cm long) with pole cap suitable for Street light Fittings complete in all respect as per direction of E/I.PWD SOR 2018 SI No-1420 CAT-AAA Make:Havells/Polycab/Philips /Jaquar 66 Supply and fixing of LED Street light Fitting having die cast Aluminium body and diffuser/Reflector with Complete driver set suitable for 45 to 50 watt. Confirming to IP 66 Protection Including Street light Bracket (60 cm long) with pole cap suitable for Street light Fittings complete in all respect as per direction of E/I.PWD SOR 2018 SI No-1421 CAT-AAA Make:Havells/Polycab/Philips /Jaquar 67 Making suitable earth of GI pole with 2.5 Mts. long 20mm M.S rod connected with 7/16 SWGG.S. wire duly clamped & binded on pole including the cost of materials, labour and T & P required for proper completion of work as per direction of E/I. 68 Supply of following size of Al. conductor XLPE Insulated, Cores Laid up, PVC Innersheathed, Armouredwith Galvanised Al. Strip Extruded PVC Type ST2 Outer Sheathed, 650V/1100 Volt Grade as per IS 7098 (Part I) 1988 With up to date Ammendments. Make:- POLYCAB/ GLOSTER/FINOLEX / HAVELLS/ KEI/ UNIVERSAL 69 10 Sqmm 4 core 70 Supply and fixing of palm or pin copper tin plated cable socket (lugs) to the cable leads insulating with tape and making connections etc. complete in all respects (as per PWD SOR 2018 SI No 504). 71 10 Sqmm 72 S/F of following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contractors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect UPPWDSOR 2018 SI No-807 Only PWD Approved Make 73 40 A TPN 74 Supply of HDPE pipe upto PN-6 working pressure Rating material Grade PE-80 Nominal dia (OD) 63 mm 3.70 mm thicknesscomplete in all respect as per relevants I.S. Technicals specification. 75 Digging & Refilling of Same Trench Parallel to Road at a depth of 1.5 Mtr. as required & laying charges of cable & different size HDPE Pipe (PN-6 PE 80 Grade) complete with all material, labour and T&P etc. required for proper completion of work as per Direction of E/I.