}

Tender For Procurement Of Consumable Items For Two Years From The Date Of Award Of Contract (Aoc), Kolkata-West Bengal

Central Medical Stores Department has published Tender For Procurement Of Consumable Items For Two Years From The Date Of Award Of Contract (Aoc). Submission Date for this Tender is 05-07-2024. Medicine Tenders in Kolkata West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

43650416
Tender For Procurement Of Consumable Items For Two Years From The Date Of Award Of Contract (Aoc)
Tender
Indian
West Bengal
Kolkata
05-07-2024

Tender Details

Tender For Procurement Of Consumable Items For Two Years From The Date Of Award Of Contract (Aoc) Membrane Oxygenator (coating) with inbuilt Arterial Filter (Paediatric) - Priming Volume of 135 ml. Blood Flow range up to 4.0 L / min. Reservoir capacity of 3000 ml; 70 ml minimum operating level. Non heparin based bioppassive polymer does not react with blood components. Oxygenator (coating) with inbuilt Arterial Filter ( Adult )- Priming Volume of 270 ml. Large blood flow rate of up to 7.0 L / min. Large reservoir capacity of 4000 ml; 200 mL minimum operating level. Non heparin based bioppassive polymer does not react with blood components. Oxygenator (coating) with inbuilt Arterial Filter (Neonatal) - Priming Volume of 43 ml. Blood Flow range up to 0.1 L / min, Max 1.5 L /min Reservoir capacity of 1000 ml; 15 mL minimum operating lavel. Non heparin based bioppassive polymer does not react with blood components. Renal Guide Catheter (contra 7Fr.) • 45 - 55cm in length TROLLEY, DRESSING DRUM IS 7099 Inline Nebulization system should be capable generate < 3-micron uniform particle. Should be capable of delivering of all clinically certified aerosol drugs, antibiotics & vaccines for neonatal to adult. It should be a fast and silent operating system and easy to setup. Inline Nebulization machine ( Controller System) i. The Nebulization unit should operate on vibrating mesh technology to generate uniform particle of 1-5 micron and should controlled with wired controller. ii. The system should have a microprocessorbased controller to aerosolize the drug through the nebulisation unit. iii. The should be operated with AC/DC adapter (input 100 to 240 VAC 50-60 Hz, output 9V) or from a USB port on medical electrical equipment. iv. The AC/DC adapter should be warranted against defects in manufacturing for a period of two years from the date of purchase Nebulization chamber with adapter 1. Nebulization unit should be capable of using with multiple modalities like mechanical ventilator, non-invasive ventilator, HFNC/HFOV machines, stand-alone nebulisation and continuous Nebulization. 2. It should be capable to support Nebulization through standard syringe pumps with dedicated / standard luer connectors eliminate the risk of misconnection. 3. Drop-by-drop continuous Nebulization control with the tubing priming volume range 2- 4ml. 4. The input rate of medication into the Nebulization unit under continuous Nebulization sgould be in a range of 10- 12ml/hr. 5. the standalone Nebulization should be used with or without O2 via mouthpiece or mask 6. the Nebulizer should be validated for single patient use for up to 30 days intermittent use based upon a typical usage profile of 4 treatments per day or 7 days continuous use with the continuous Nebulization tube set.

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail