| 1 | CIVIL |
| 2 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 3 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 4 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 5 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stoneaggregate 20 mm nominal size). |
| 7 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 8 | CEMENT PLASTER (IN FINE SAND) 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) |
| 9 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick |
| 10 | Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. |
| 11 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 12 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer |
| 13 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) : |
| 14 | Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification.Two or more coats on new work |
| 15 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work |
| 16 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution |
| 17 | Applying a coat of mordant solution on G.S. sheet: With a solution of 38 gms of copper acetate in a litre of soft water |
| 18 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides |
| 19 | \"Disposal of moorum/ building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-Charge. |
| 20 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: acrylic sheet |
| 21 | Providing and fixing 6mm thick mulitwall polycarbonate sheet of approved colour and shade and of approved mark in reuired shape over M.S Frame work and fixed with required beading, EPDM gasket, self taping screw including cutting, placing, wastage all labour and materials etc as per the direction of Engineer-in- charge |
| 22 | Cleaning of porta cabin of size 3.5 X 4.95 X 3.00 mtr. with thinner /soap detergent etc. as per direction of Engineer In charge. |
| 23 | Electrical work |
| 24 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A |
| 25 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm |
| 26 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. 3 x 6 sq. mm |
| 27 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch |
| 28 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet |
| 29 | Supplying and fixing following Modular base & cover plate on existing modular PVC/ metal boxes etc. as required. 6 Module |
| 30 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) 12 way, Double door |
| 31 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 32 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole |
| 33 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 35 sq. mm |
| 34 | Supplying,fixing, connecting, commissioning & testing of ceiling fan 900 mm sweep, BEE 5 Star rated without regulatorincluding wiringwith 1.5 sqmm PVC insulated copper wire single core cablecomplete as reqd. [Halonix Zephyr 36-inch 75-Watt Power Saver Ceiling Fan (White), 400 rpm] or equivalent make Crompton Greaves Greaves,Bajaj,Havels) |
| 35 | Supplying,fixing, connecting, commissioning & testing of ceiling fan 1200 mm sweep, BEE 5 Star rated without regulatorincluding wiringwith 1.5 sqmm PVC insulated copper wire single core cablecomplete as reqd. [Halonix Zephyr 48-inch 75-Watt Power Saver Ceiling Fan (White), 350 rpm] or equivalent make Crompton Greaves Greaves,Bajaj,Havels) |
| 36 | Supplying, installation, testing and commissioning of exhaust fan of 300 mm in the existing opening, including making good the damage and as per direction of Engineer - in- charge. |
| 37 | Supplying, Installation, Testing and Commisioning ofIndoor decorative 20 Watt LED plastic batten withopal diffuser IP20 mimimum 2000 lumens with cool day light and operating voltage of 240V complete as required.(Halonix Part no. HLB-33-20-CW-IP or its equivalent, Havells, Crompton Greaves) |
| 38 | Supplying and fixing following size/modules, PVC box for modular switches and sockets on surface etc. as required. 6 module |
| 39 | Supplying and Fixing PVC Casing& capping of 25 MM for power circuit wiring. |
| 40 | Supplying and fixing one module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 41 | Supplying following size PVC INSULATED & FRLS MULTI CORE Round Sheathed Bright Annealed Bare Copper Conductor Heavy Duty Industrial Cables for Voltage Gradeupto 1100 Volts as per IS: 694:2010. 3 x 16 sq.mm |