Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #43625511

Tender For Repair/Maintenance Of Lt Panels, Servo Stablizers, Mccbs, Lt Cable For Lkt At Af Station Bhowali.

Issued by Statutory Bodies & Commissions/Committees · bhowali, Uttarakhand
Tender Value
7.50 Lakhs
Estimated cost
Bid Submission
13 Jul 2024
0 days left
EMD
15000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
bhowali → Uttarakhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Repair/Maintenance Of Lt Panels, Servo Stablizers, Mccbs, Lt Cable For Lkt At Af Station Bhowali.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 01-Jul-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 08-Jul-2024
2 08-Jul-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-Jul-2024

BOQ

Name of Work :REPAIR/MAINT OFLT PANELS, SERVO STABLIZERS,MCCBs, LT CABLE FOR LKT AT AF STATION BHOWALI.
Sl. No. Item Description
1Dismantling & taking out LT burnt cable ends of any size from transformer/LT panel/LT feeder pillar/ street light pole box/trenches any type/size, for repair/making suitable for reconnection to cable, providing lugs to burnt end of cables, preparing fresh terminals and reconnection, fixing the removed portion of cable with transformer/in trenches/along pole/ panel/feeder pillar box, including excavation of loop & refilling complete using old bricks and sand returning filling the excavated soil complete all ss specified and directed.
2M&L for dismanteling of of old damaged /cracked PCC coping and prepare the new copingfor steel/PCC pole using PCC 1:3:6 type D-2 with 20 mm graded stone aggregate making collar aboveground level on existing foundation of pole size 450x450x300 mm high and plastering with1:4 cement sand mixter for smooth look incl curing to achieve the strength and breaking/removing existing old damaged coping complete all as specified and directed .
3Repair of earth pit incl required excavation ,earth work and PCC work to make good damaged /disturbed surfaces of earth pit chamber & making new pit cover of RCC 1:2:4 type B1 using 20 mm graded stone aggregate reinforced and lifting handle on RCC cover with 8 mm bars at 150 mm centre to centre both ways incl supply & fixing of wire mess and funnel including re-connection of earth wire/strip with panel/transformer using GI nut, bolts washer complete all as specified and directed
4Checking, identifying the defect /faulty point ofLT cable using Cable fault locator machine or by manual excavation and taking out bricks from the trench uptofaultpoint along cable routeand re-layingthe sameusing old bricks/sand incl returning filling and making goodsurface after rectification of defect complete all as directed for the following lengthof cable :
5(a) 0 -150 mtr
6(b) 0 - 200 mtrNote- (i)Cable fault locator machine with all T&Prequired for identifying the faulty point will be arrange by contractor and thecost isincluded in unit rate for finding of fault using machine or by manualy
7Dismantling & taking out defective LT PVC/XLPE cable from trenches with cutting and removing defective parts and supply & making cable joint using strait through joint cold shrink type and making connection of LT cables, meggering & re-storation of electric supply complete including jointing materialfor the following sizes of cable :- Joint make- Reychem
8(a) 25 sqmm 3.5 core to 70 sqmm, 3.5 core
9(b) 95 sqmm 3.5 core to 240 sqmm 3.5 core
10Trimming/cutting of tree /removal of bushes/removal of vegetation growth/cutting trunk portion protruding over ground, digging out rootsarround 2 mtr radius ofLT panel and removal from site all as directed Note : this job may be repeated after three month at the same location.
11M & L for spray painting of old/existing out door LT panel/feeder piller box any size/type( with powder coated paint usinglight grey paint in outerside areaof complete panel after cleaning and preparing surface incl sign writing & writting of panel No complete all as specified & directed
12S&F (in replacement) following items in the existing out door/ indoor LT panelsand connection with using aluminum lugs/ferruls incl disconnection & connection of cable andmaking necessary alteration in panel/door using welding wk and cutting as required for proper fixing & connection complete all as specified and directed as below :- (Note :-Make of MCCB/MCB
13(a) MCCB 4 Pole63 amps rating, 16 KA breaking capacity, 415 Volt
14(b) MCCB 4pole 100 amps rating, 16 KA breaking capacity with spreaderat bothe side
15(c) MCCB 4 pole150/160 amps rating, 36 KA breaking capacity with spreaderat bothe side
16(d) MCCB 4 pole 200 amps rating, 36 KA breaking capacity with spreaderat bothe side
17(e) MCCB 4 pole 250 amps rating, 36 KA breaking capacitywith spreaderat both side
18(h) Volt meter (0 to 500 volts) anologtype with selector switch for three phase
19(j)Amp meter (0 to 500 amps) anolog type,witch selector switch for three phase measurement .
20(k) CTs of existing ratio and capacity fixed in LT panels and connect with ammeter
21(l) Indicator lamp, LED type incl 1.5 sqmm wire for connection to desired point of bus bar.
22(m) MCB TPN 63 amps, \"C\" series, 415 volt
23M&L for boring under road horizontely of size 50/80 mm bore of GI pipe for passing of cable in road in hard/soft/ loose soilcomplete all as specified and directed.
24Disconnecting & dismentling of damaged/unsv cable any type /make and Supply & laying (in repair) cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor using lugs bothe end of cable& wrapping pvc tape over XLPE insulation cable and testing complete all as directed for following size :- (Note:- Excavation & earth work, sand cushioning, bricks protection & GIpipe where required shall be measured & paid seperately)
25(a) 25 Sqmm 4 core
26(b) 50 Sqmm 3.5 core
27(c) 95 Sqmm 3.5 core
28Excavation in trenches in hard/dense soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for taking out/laying cable, poles &stay etc complete all as specified and as directed by Engr-in-Charge.
29Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid tested complete all as specified and as directed by Engineer-in-Charge
30Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed by Engr-in-charge
31M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm.
32M&L for brick laid in trenches for cable protection of burnt clay sub class ‘B’ complete laid dry flat.
33M&L(in replacement) for laying of GI Pipe medium grade of 50 mm bore diain trenches /under road crossing/fixed on pole/wall/under floor including suitable mild steel FI clamps of required size complete all as specified and as directed by Engineer-in-Charge
34M & L for busbar chamber box of 1.6 mm sheet with tinned plated 04 Nos copper bars of following bus bar and following box size, factory made, suitable for pole/wall mounted including all connections with aluminum strips/lugs, glands to be provided at cable entries, powder coated paint complete for the following rating:-
35(a) Bus bar of rating 100 amps
36(b) Bus bar of rating 200 amps
37S&F MCCB 4 pole, 415 volts with suitable size of sheel metal enclosure and connection with using aluminum lugs and making arrangement to fix on wall or on PCC(1:2 :4) Bock complete for the following capacity/rating:-
38(a) 63 amps rating, 25 KA breaking capacity with bothe sidespreader for cable connection
39(b) 100 amps rating, 25 KA breaking capacity with bothe sidespreader for cable connection
40Repairing/overhauling of existingOut door type LT panel board/feeder pillar box of any size/type fixed on PCC block incl cleaning with compressed air, tightening of all electric connection to the bus bar & switch gears , refixing of loosed doors withproper fixing & locking arrangement &necessary welding work as required and replacement of wornout/ burnt/rusted/ loose lugs , door lock, nut bolt,hing, washers,internal wiring with suitable size (minimum 1.5 sqmm) of PVC copper conductor wire ,repair to PCC workas require at site and including disconnection of all cable from the bus bar and insulating the neked portion ofAl conductorand re-connect the sameafter repair of panel and proper connection of main earth wire/lead with panel body using lugs complete all as specified and directed.
41Description all as per item No. 26 above butindoor type penal fixed at power house & pump houses complete all as specified and directed.
42Repairing/overhauling of existingindoor type LT panel board/bus bar / V-TPN DBs of any size/type fixed on building wallincl cleaning with compressed air, tightening of all electric connection to the bus bar& switch gears , refixing of loosed doors withproper fixing & locking arrangement &necessary welding work as required and replacement of wornout/ burnt/rusted/ loose lugs , door lock, nut bolt,hing, washers,internal wiring with suitable size (minimum 1.5 sqmm) of PVC copper conductor wire ,repair to plaster workas require at site and including disconnection of all cable/ sub main from the bus bar and insulating the neked portion ofAl conductorand re-connect the sameafter repair of panel and proper connection of main earth wire/lead with panel body using lugs complete all as specified and directed.
43M& L for preparing door of existingLT panel / feeder pillar box withlocking arrangement & gasketedmade of CRCA sheet 2 mm thick including hing & welding work complete all as specified and directed.
44Supply & fix (in replacement) copper strips 20x3 mm onporcelin insulator 15 BMD type \"T\" placed not more than 50 cm apart including copper nut & bolts & brazing etc. complete all as specified & directed by Engr - in - Charge .( Note :Insulators will be measured and paid separatly under relavent items)
45S&F (in replacement)test point terminal block made out of gun metal or phosphorous bronze size 150x150x75 mm depth , drolled , cutting upper & lower portion for incoming & outgoing including double insulators two coat of synthic enamel paint complete as directed .
46S&F (in replacement) porceliene insulators 15 BMD type T with nut bolts / screws for fixing ofaluminium strips on roof including provn ofPCC of size 10cmX10cmX10cm heightetcto avoid leakage of roof complete as directed.
47Servicing/overhaulingof servo voltage stablizers of ranging from 30 KVA to 150 KVA capacity, detection of defective components, replacement of worn out parts and servicing/ cleaning of mechanical components after drawout of coil if required andTestingfor smooth operationafter caliberation of relaytrough OEM of servo/ and resetting the system &setting for healthy system, complete all as specified and directed by Engr-in-Charge. Note: Worn out parts shall be deemed to beincluded in quoted rate and Major parts shall be measured and paid separately are as under:
48Supply only spare parts for servo stablizersof any make (30 - 150 KVA) all as specified :-
49Digital control card of servoper existing make.
50R C network of servo complete all as required and directed at site complete all as per sample.
51Servo motor complete all as required and directed at site complete all as per sample.
52Micro switches complete all as required and directed at site complete all as per sample.
53Voltage regulating coil complete all as required and directed at site complete all as per sample.
54M&L Servo stablizer oil having di-electric strength of 60 KV as per IS complete for top up/ replacement all as specified and as directed by Engr-in-Charge. (Oil should be supplied in sealed barrel)Note: Oil shall be filled in the transformers/stabilizers to be repaired or installed at site at different locations.

AI Tender Summary

OUR REF NO 43625511
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 7.50 Lakhs
LAST DATE 13-07-2024
Authority
Authority Name Military Engineer Services
Work Description Tender For Repair/Maintenance Of Lt Panels, Servo Stablizers, Mccbs, Lt Cable For Lkt At Af Station Bhowali.
Basic Detail
Tender No 8027/E8
Bidding Type Tender
Location
City bhowali
State Uttarakhand
Key Dates
Publish Date 08 Jul 2024
Submission Date 13 Jul 2024
Open Date 15 Jul 2024
Finance
Tender Value 7.50 Lakhs
Tender Fee 500
EMD 15000
Exemption Available
Document List
325e8416-9672-4520-aeed-384e5d1ed56a.html
BOQ_736940.xls
tender8027.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 08, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 08, 2024
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 13, 2024
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 13, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 15, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

325e8416-9672-4520-aeed-384e5d1ed56a.html

xls

BOQ_736940.xls

pdf

tender8027.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders