| 1 | Providing and Installation of flow meter suitable to measuredischarge 750 cum./hr to 2000 cum/hr |
| 2 | Cost of Street light at site |
| 3 | Wiring and CablingComplete wiring and cabling as per detailed specifications i) From LT control panel to motors andothers |
| 4 | EarthingDouble loop earthing for all electricalequipment from the existing grid as perelectricity rules with 4 Nos. earth pipecomplete |
| 5 | Pipes and FittingsProviding, laying, jointing and testing C.I. D/F pipes, valves and specials required for suction and delivery pipes includingtesting etc. complete in all respect |
| 6 | Providing and Installation of flow metersuitable to measure discharge200mm i/d |
| 7 | Providing and Installation of flow metersuitable to measure discharge150mm i/d |
| 8 | Cost of Fire fighting equipment (Detailattach) |
| 9 | Provision for Electro chlorinatorysystem |
| 10 | Coating of outer surface of casing pipe with P.U coating to dry film thickness 1500 micron for protection against corrosion complete in all respects. |
| 11 | Supply and fixing of Sluice Valves IVC / Kirloskarmake 700mm i/d |
| 12 | Supply and fixing of Sluice Valves IVC / Kirloskarmake 600mm i/d) |
| 13 | Supply and fixing of Sluice Valves IVC / Kirloskarmake 400mm i/d) |
| 14 | Supply and fixing of Sluice Valves IVC / Kirloskarmake 300mm i/d |
| 15 | Providing and Installation of ` casing pumps with squirrel cage induction electric motor including testing commissioning etc. complete in all respect. i) 7200 Lpm 35 M Head with 95 HP motor.. |
| 16 | Supply and erection of Cubical type L.T. Panel board, having independent incoming and outgoing feeder, fabricated from 14 SWG, CRCA sheet. |
| 17 | Supply and erection of Hand operated Travelling crane with Trolley and Chain Block complete 2 tonne capacity.... |
| 18 | Providing and Installation of ` casing pumps with squirrel cage induction electric motor including testing commissioning etc. complete in all respect. i) 145 Lps 35 M Head with 115 HP motor.. |
| 19 | Supply and erection of Cubical type L.T. Panel board, having independent incoming and outgoing feeder, fabricated from 14 SWG, CRCA sheet.. |
| 20 | Providing and Installation of Horizontal split casing pumps with squirrel cage induction electric motor including testing commissioning etc. complete in all respect. i) 195 lps 35 M Head with 155 HP motor.. |
| 21 | Supply and erection of Cubical type L.T. Panel board, having independent incoming and outgoing feeder, fabricated from 14 SWG, CRCA sheet... |
| 22 | Provision for Supply and Erection of Sump Pump, Dewatering pump and vacuum pump complete... |
| 23 | Providing and Installation of ` casing pumps with squirrel cage induction electric motor including testing commissioning etc. complete in all respect. i) 120 Lps 35 M Head with 95 HP motor.. |
| 24 | Supply and erection of Cubical type L.T. Panel board, having independent incoming and outgoing feeder, fabricated from 14 SWG, CRCA sheet |
| 25 | Supply and erection of Cubical type L.T. Panel board, having independent incoming and outgoing feeder, fabricated from 14 SWG, CRCA sheet.... |
| 26 | Providing and Installation of ` casing pumps with squirrel cage induction electric motor including testing commissioning etc. complete in all respect. i) 170 Lps 35 M Head with 135 HP motor.. |
| 27 | lying and fixing openable anodized (15 micron) aluminium doors and windows |
| 28 | SRP coating |
| 29 | Supply, Erection,testing and commissioning ofPuffin 18W White Round Bright LED Panel LightCeiling Downlight Lamp Kit with LED DriverSurface Mount LED Ceiling Light (Pack of 1)(2Year Warranty Make:-Philips,Bajaj,GE,Wipro,K-lite,cromptongreaves |
| 30 | Supplying fixing, testing and commissioning M.S D/F pipe for scouring arrangement complete in all respects to the satisfaction of Engineer-in-charge. 250mm i/d |
| 31 | Providing under reamed cast in situ piles using controlled concrete grade M-30 designed mix, 6.5m deep including boring and getting out the soil and disposal upto a lead of 100 m including cost of steel reinfocement, jointing the tiles with main bar with welding and also all T and P retuined completed in all respect the code followed 400 mm dia under reamed. |
| 32 | Supply and painting 2 coat of shalpoxy CTC (LB) type coalar epoxy to protect steel structure complete to the entire satisfaction of the engineer-in-charge. |
| 33 | Boring/excavation including making thrust pit and receiving pit to the precise dimensions for the launch of the specialized Auger boring machine in normal soil condition but not in Rock/boulders/any underground utility like foundation, water supply line coming in alignment or other under ground obstruction under KGP express way suitable for M.S casing pipe of following sizes including caution and sign board complete in all respects. i) for 724 mm o/d M.S pipe 12 mm thick casing pipe. |
| 34 | Providing and insertion of M.S Casing pipe (Fe-330 grade) fabricated as per IS : 3589 of 1991 from steel plates confirming to IS-2062 of following size including cutting, beveling grinding and radio graphically welding of pipes as per IS-1182 complete in all respect including cartage to site of work and testing. i) for 724 mm o/d M.S pipe 12 mm thick casing pipe. |
| 35 | Providing and insertion of water supply pipe 416 mm o/d M.S pipe 8mm thick (Fe-330 grade) fabricated as per IS : 3589 of 1991 from steel conforming to IS : 2062, including inner lining by cement concrete mortar which shall be prepared from aggregates/sand and cement mixed in ratio 2:1 by weight with minimum cement content of 450 Kg/M3 having strengh of 25 N/mm2 after 20 days complete as per IS: 1916-1989 with latest revision, providing roller arrangement for smooth insertion and anchoring of pipe through out the length with HDPE spacers at distance of 2 m apart to aviod contract of casing pipe and carrier pipe including cutting, joining, radio graphically welding as per IS: Hydraullic testing complete in all respects. |
| 36 | Cleaning of surface of M.S pipe (casing pipe and carrier pipe) inner surface and outer by sand blasing at site to make the surface ready for P.U. coating/High built epoxy paint/polythene tap system complete in all respects. |
| 37 | coating of outer surface of casing pipe with P.U coating to dry film thickness 1500 micron for protectio against corrosion complete in al respects. |
| 38 | coating of outer surgace of water carrier pipe with polythene tape system for protection against corrosion complete in all respect. |
| 39 | Coating of inner surface of casting pipe with High built epoxy paint to R.D.S.O. specification no MandC/PCN/111/88 to a dry film thickness of 250 micron. |
| 40 | Providing and fixing H.D.P.E spacer at a distance of 2 m apart to avoid contact of casing pipe and carrier pipe complete in all respect.i) for 724 mm o/d M.S Pipe |
| 41 | Providing concrete block 1:11/2 : 3 on both ends to plug the annular space between casing and carrier pipe including coast of 5mm thick M.S. end plate complete in all respect. i) for 724 mm o/d casing pipe |
| 42 | Ground probe radar survey to check any under ground obstruction before finalizing the alignment. |
| 43 | Boring/excavation including making thrust pit and receiving pit to the precise dimensions for the launch of the specialized Auger boring machine in normal soil condition but not in Rock/boulders/any underground utility like foundation, water supply line coming in alignment or other under ground obstruction under KGP express way suitable for M.S casing pipe of following sizes including caution and sign board complete in all respects. i) for 1340 mm dia per insertion of 1300 mm id M.S pipe |
| 44 | Providing and insertion of M.S Casing pipe (Fe-330 grade) fabricated as per IS : 3589 of 1991 from steel plates confirming to IS-2062 of following size including cutting, beveling grinding and radio graphically welding of pipes as per IS-1182 complete in all respect including cartage to site of work and testing. i) for 1340 mm i/d M.S casing pipe 20 mm thick. |
| 45 | Providing and insertion of M.S Casing pipe (Fe-330 grade) fabricated as per IS : 3589 of 1991 from steel plates confirming to IS-2062 of following size including cutting, beveling grinding and radio graphically welding of pipes as per IS-1182 complete in all respect including cartage to site of work and testing. i) for1240 mm i/d M.S casing pipe 16 mm thick. |
| 46 | Providing and insertion of water supply pipe 416 mm o/d M.S pipe 8mm thick (Fe-330 grade) fabricated as per IS : 3589 of 1991 from steel conforming to IS : 2062, including inner lining by cement concrete mortar which shall be prepared from aggregates/sand and cement mixed in ratio 2:1 by weight with minimum cement content of 450 Kg/M3 having strengh of 25 N/mm2 after 20 days complete as per IS: 1916-1989 with latest revision, providing roller arrangement for smooth insertion and anchoring of pipe through out the length with HDPE spacers at distance of 2 m apart to aviod contract of casing pipe and carrier pipe including cutting, joining, radio graphically welding as per IS: Hydraullic testing complete in all respects. |
| 47 | Coating of inner surface of casting pipe with High built epoxy paint to R.D.S.O. specification no MandC/PCN/111/88 to a dry film thickness of 250 micron. |
| 48 | Providing and fixing H.D.P.E spacer at a distance of 2 m apart to avoid contact of casing pipe and carrier pipe complete in all respect. i) for 724 mm o/d M.S Pipe |
| 49 | Providing concrete block 1:11/2 : 3 on both ends to plug the annular space between casing and carrier pipe including coast of 5mm thick M.S. end plate complete in all respect. i) for 1340 mm o/d casing pipe |
| 50 | Ground probe radar survey to check any under ground obstruction before finalizing the alignment.for 1340 mm o/d casing pipe |
| 51 | Boring/excavation including making thrust pit and receiving pit to the precise dimensions for the launch of the specialized Auger boring machine in normal soil condition but not in Rock/boulders/any underground utility like foundation, water supply line coming in alignment or other under ground obstruction under KGP express way suitable for M.S casing pipe of following sizes including caution and sign board complete in all respects. i) for 1124 mm o/d 12 mm thick casing pipe. |
| 52 | Supply and fixing Terra cota tile 25mm thick in wall facing (lining) on wall.. |
| 53 | Cost of supply and erection of CFL/Tube light.. |
| 54 | Porv. and fixing of chequered plates 6 mm thick complete including cutting and welding etc. |
| 55 | Providing under reamed cast in situ piles using controlled concrete grade M-30 designed mix, 6.5m deep including boring and getting out the soil and disposal upto a lead of 100 m including cost of steel reinfocement, jointing the tiles with main bar with welding and also all T and P retuined completed in all respect the code followed 400 mm dia under reamed. |
| 56 | Providing and fixing M.S chequered plates 5 mm thick complete including cost of cutting and welding on steel truss bridge agra canal complete in all respect. |
| 57 | Hiring of heavy duty crane for lifting of truss brideges to place on various crossing including cost of labour, fuel TandP etc. complete in all respects taking working period 2 days deploing of 4 nos. heavy duty crane on both end of bank including insurance of stucture to be placed and workmen executing the work o placing of truss bridge in position as a complete job. up to span of 5- 15 mtr............ |
| 58 | Hiring of heavy duty crane for lifting of truss brideges to place on various crossing including cost of labour, fuel TandP etc. complete in all respects taking working period 2 days deploing of 4 nos. heavy duty crane on both end of bank including insurance of stucture to be placed and workmen executing the work o placing of truss bridge in position as a complete job. up to span of 15- 30 mtr........... |
| 59 | Hiring of heavy duty crane for lifting of truss brideges to place on various crossing including cost of labour, fuel TandP etc. complete in all respects taking working period 2 days deploing of 4 nos. heavy duty crane on both end of bank including insurance of stucture to be placed and workmen executing the work o placing of truss bridge in position as a complete job. up to span of 30-50 mtr. |
| 60 | Boring/excavation including making thrust pit and receiving pit to the precise dimensions for the launch of the specialized Auger boring machine in normal soil condition but not in Rock/boulders/any underground utility like foundation, water supply line coming in alignment or other under ground obstruction under KGP express way suitable for M.S casing pipe of following sizes including caution and sign board complete in all respects. i) for 724 mm o/d M.S pipe 12 mm thick casing pipe..... |
| 61 | Providing and insertion of M.S Casing pipe (Fe-330 grade) fabricated as per IS : 3589 of 1991 from steel plates confirming to IS-2062 of following size including cutting, beveling grinding and radio graphically welding of pipes as per IS-1182 complete in all respect including cartage to site of work and testing. i) for 724 mm o/d M.S pipe 12 mm thick casing pipe........... |
| 62 | Providing and Installation of ` casing pumps with squirrel cage induction electric motor including testing commissioning etc. complete in all respect. i) 135 Lps 35 M Head with 105 HP motor. |
| 63 | Cost of Fire fighting equipment |
| 64 | DNIT FOR CONSTRUCTION OF 4 NO RANNEY WELLS, LAYING OF RISING MAIN, CONSTRUCTION OF MBS AT VILLAGE CHANDHAT and JANACHOLI FOR AUGMENTATION IN WATER SUPPLY IN PALWAL and NUH ` Construction of 8 Nos Intermediate Boosting Station, laying, jointing, testing and commissioning of DI Pipe line of various size and all other works contingent thereto`Operation and maintenance during defect liability period after 3 month trial run period (operation only) |
| 65 | 1st year Operation and maintenance afterdefect liability period |
| 66 | 2nd year Operation and maintenance |
| 67 | 3rd year Operation and maintenance |
| 68 | 4th year Operation and maintenance |
| 69 | 5th year Operation and maintenance |